Attachment 10d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx
XLSX spreadsheet 11 MB Posted
- Attached to
- DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
- Solicitation number
- W31P4Q-20-R-0015
About this file
This document contains a preliminary failure modes and effects criticality analysis (FMECA) for shelters housing RS-112 servers, and a draft request for proposal for the Integrated Battle Command System hardware low rate initial production/full rate production.
The FMECA examines potential failure modes for RS-112 server shelters, including improper or loss of data, improper indication, improper operation, poor air flow from fans, shorts, electrical overstress, and other issues. It analyzes the effects of each failure mode at the component, next higher system, and overall system levels. The document assigns severity classifications and considers compensating provisions and design modifications to reduce risk.
The draft RFP seeks hardware production for the Integrated Battle Command System, including maintaining approved software/firmware updates, cybersecurity, and authority to operate on existing hardware. Engineering changes may be required for obsolescence, new capabilities, and export. It was issued by the Department of the Army Materiel Command Contracting Command at Redstone Arsenal for comment only, and does not constitute a solicitation for proposal submission.
View the file
Other files for this federal contract opportunity
Show all 50
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .