Attachment 10c.13 – E063 Isolation Router Black-FMECA.xlsx

XLSX spreadsheet 43 KB Posted

Attached to
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document contains a Failure Modes and Effects Criticality Analysis (FMECA) for an isolation router and related federal contract opportunity. The FMECA identifies 29 potential failure modes for the router including erroneous LED indications, faulty switches, faulty fans, shorts, data bit errors, electrical overstress, data word failures, failure to operate at prescribed times, opens, and faulty components. It analyzes the effects of each failure mode on the router and higher level systems. The related federal contract opportunity is a draft request for proposal for the Integrated Battle Command System hardware low rate initial production and full rate production. It involves producing IBCS hardware in accordance with technical data packages and specifications, maintaining approved software and firmware updates, and executing any engineering changes for obsolescence, new capabilities, or export considerations. The solicitation number is W31P4Q-20-R-0015 and it is issued by the Department of the Army Materiel Command Contracting Command at Redstone Arsenal.

View the file

Other files for this federal contract opportunity

Other files attached to DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
Attachment 22a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 15b - Fixed Price Level of Effort Labor Categories.xlsx XLSX spreadsheet
Attachment 10h - SWFMEA RESULTS.xlsx XLSX spreadsheet
Attachment 22a.1.h - PL-ALH-211130 00 CABLE ASSEMBLY CASS DC POWER.pdf PDF
Attachment 04c - ECT_Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 22a.1.a - ALH-208670 05 IBCS SHELTER INTERCONNECT.pdf PDF
Attachment 10a.4 – R004 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 13 - Training Documentation.docx DOCX document
Attachment 10a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.j - PL-ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 10c.5 – E050 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 10b.9 – E033 R112 Shelter – Server Stack – 03-FMECA.xlsx XLSX spreadsheet
Attachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 10a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 19 - Section L - Instructions - Conditions - And Notices To Offerors.docx DOCX document
Attachment 10c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 10e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.b - ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 10c.1 – E043 Firewall Red-FMECA.xlsx XLSX spreadsheet
Attachment 02 - AIAMD System of Systems (SoS)(MIS-PRF-56500).pdf PDF
Attachment 10b.1 – E001 28VDC Pwr Supply Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10e.11 – E149 – Table 5 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10d.2 – E144 RWS Bkup Batteries-FMECA.xlsx XLSX spreadsheet
Attachment 12 - Risk Management Plan.pdf PDF
Attachment 21 - Task Order 0001 Statement of Work.docx DOCX document
Attachment 10c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 10a.16– R034 Media Converter Power Supply-FMECA.xlsx XLSX spreadsheet
W31P4Q-20-R-0015_DRAFT_28 May 2020.pdf PDF
Attachment 10a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 04b - Draft_Relay Acceptance Test Procedures.docx DOCX document
Attachment 13c - IBCS-A301-003 Vol II Instructor Guide.pdf PDF
Attachment 22a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 22a.1.d - ALH-213030 00 CABLE ASSEMBLY, CASS J1 AND J3.pdf PDF
Attachment 10a.14 – R032 Media Converter Module 11-FMECA.xlsx XLSX spreadsheet
Attachment 20 - Section M - Evaluation Factors For Award.docx DOCX document
Attachment 22a - CASS to PDRS.docx DOCX document
Attachment 10d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10e.10 – E148 – Table 4 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10e.5 – E122 – EMI Tent PDU-FMECA.xlsx XLSX spreadsheet
Attachment 17 - Pre-Award Survey Accounting System Checklist.pdf PDF
Attachment 22a.1.g - PL-ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 22a.1.e - ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 22a.4 - CASS Task Purpose.pptx PPTX presentation
Attachment 10a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 10c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 03 - GFP Attachment - LRIP_FRP - 20 April 2020.xlsx XLSX spreadsheet
Attachment 04 - Acceptance Test Plan.docx DOCX document
Attachment 10b.8 – E032 R112 Shelter – Server Stack – 02-FMECA.xlsx XLSX spreadsheet
Show all 50

DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet2

Row LabelsSum of CmCount of Failure Mode Description
Erroneous LED indication4.83E-057
Faulty Switch3.45E-056
Faulty Fan2.87E-055
Short6.90E-063
Data bit error4.60E-062
Electrical Overstress1.15E-061
Data word failure1.15E-061
Failure to operate at a prescribed time1.15E-061
Open1.15E-061
Faulty Component1.15E-061
Under/over voltage1.15E-061
Grand Total1.30E-0429

Prelim Analysis

Major End Item:Shelter - Router and Switches
Parent LRU:E063-Isolation Router (Blk)
Component:ISOLATION ROUTER - BLK (A318)
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =1.30E-04
Failure ModesCount of
Failure ModesSeverity ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Erroneous LED indication724.14%Category III26Erroneous LED indication4.83E-057
Faulty Switch620.69%Erroneous LED indication6Faulty Switch3.45E-056
Faulty Fan517.24%Faulty Switch5Faulty Fan2.87E-055
Short310.34%Faulty Fan5Short6.90E-063
Data bit error26.90%Short2Data bit error4.60E-062
Electrical Overstress13.45%Data bit error2Electrical Overstress1.15E-061
Data word failure13.45%Electrical Overstress1Data word failure1.15E-061
Failure to operate at a prescribed time13.45%Data word failure1Failure to operate at a prescribed time1.15E-061
Open13.45%Failure to operate at a prescribed time1Open1.15E-061
Faulty Component13.45%Open1Faulty Component1.15E-061
Under/over voltage13.45%Faulty Component1Under/over voltage1.15E-061
Grand Total29Under/over voltage1Grand Total1.30E-0429
Category IV3
Short1
Erroneous LED indication1
Faulty Switch1
Grand Total29

Cat I and Cat II No Category I and Category II Classifications

E063 Data

Major End Item:Shelter - Router and Switches
Parent LRU:E063-Isolation Router (Blk)
Component:ISOLATION ROUTER - BLK (A318)
Mission Phase-Operational Mode:All Phases
FPMH:9.258
t:72hr
Cr = ∑Cm =1.30E-04
Modified Cr =1.30E-04
No Category I and Category II Classifications
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeveverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
2005Common Cause EventsFaulty ComponentHardware FailureComponent InoperativeLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06
2006Power & Power Distribution.Failure to operate at a prescribed timeHardware FailureLoss of regulated DC powerLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06
2007Power & Power Distribution.Under/over voltageHardware FailureLoss of regulated DC powerLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06
2008Power & Power Distribution.ShortHardware FailureLoss of regulated DC powerLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AShelter CB-22 TRIPSTBDCategory IIIEOCs are RedundantCategory III0.050.051.03E-019.26E-063.45E-063.45E-06
2009Power SwitchFaulty SwitchHardware FailureSwitch opens early/unexpectedlyLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.07E-019.26E-066.90E-066.90E-06
2010Power SwitchFaulty SwitchHardware FailureSwitch opens early/unexpectedlyLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.07E-019.26E-066.90E-066.90E-06
2011Power SwitchFaulty SwitchHardware FailureSwitch opens early/unexpectedlyLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.07E-019.26E-066.90E-066.90E-06
2012Power SwitchFaulty SwitchHardware FailureSwitch opens late or not at all when requiredLoss of ability to remove power when requiredCorrective maintenance required.N/AN/AN/AN/ATBDCategory IVEOCs are RedundantCategory IV0.000.002.07E-019.26E-060.00E+000.00E+00
2013Power SwitchFaulty SwitchHardware FailureSwitch opens early/unexpectedlyLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.07E-019.26E-066.90E-066.90E-06
2014Power SwitchFaulty SwitchHardware FailureSwitch opens early/unexpectedlyLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.07E-019.26E-066.90E-066.90E-06
2015Power SwitchShortHardware FailureSwitch opens late or not at all when requiredLoss of ability to remove power when requiredCorrective maintenance required.N/AN/AN/AN/ATBDCategory IVEOCs are RedundantCategory IV0.000.001.03E-019.26E-060.00E+000.00E+00
2016Switch coolingFaulty FanHardware FailureDegraded air movement by fan assembly.Possible Loss of WIN-T Black Data due to elevated interior temperaturesPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.72E-019.26E-065.75E-065.75E-06
2017Switch coolingFaulty FanHardware FailureDegraded air movement by fan assembly.Possible Loss of WIN-T Black Data due to elevated interior temperaturesPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.72E-019.26E-065.75E-065.75E-06
2018Switch coolingFaulty FanHardware FailureDegraded air movement by fan assembly.Possible Loss of WIN-T Black Data due to elevated interior temperaturesPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.72E-019.26E-065.75E-065.75E-06
2019Switch coolingFaulty FanHardware FailureDegraded air movement by fan assembly.Possible Loss of WIN-T Black Data due to elevated interior temperaturesPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.72E-019.26E-065.75E-065.75E-06
2020Switch coolingFaulty FanHardware FailureDegraded air movement by fan assembly.Possible Loss of WIN-T Black Data due to elevated interior temperaturesPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.72E-019.26E-065.75E-065.75E-06
2021LEDsErroneous LED indicationHardware FailureLoss of LED brightnessNo EffectNo EffectN/AN/AN/AN/ATBDCategory IVEOCs are RedundantCategory IV0.000.002.41E-019.26E-060.00E+000.00E+00
2022LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2023LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2024LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2025LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2026LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2027LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2028NIPR DATAOpenHardware FailureNo data throughputLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06
2029NIPR DATAElectrical OverstressHardware FailurePossible loss of data throughputPossible Loss of WIN-T Black DataPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06
2030NIPR DATAData bit errorSoftware error (design defect)Spurious data transmittedPossible Loss of WIN-T Black DataPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.056.90E-029.26E-062.30E-062.30E-06
2031NIPR DATAShortHardware FailureUnreadable data streamingLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.03E-019.26E-063.45E-063.45E-06
2032NIPR DATAData bit errorHardware FailureUnreadable data streamingLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.056.90E-029.26E-062.30E-062.30E-06
2033NIPR DATAData word failureSoftware error (design defect)Unreadable data streamingLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06

Sheet1