Attachment 10c.13 – E063 Isolation Router Black-FMECA.xlsx
XLSX spreadsheet 43 KB Posted
- Attached to
- DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
- Solicitation number
- W31P4Q-20-R-0015
About this file
This document contains a Failure Modes and Effects Criticality Analysis (FMECA) for an isolation router and related federal contract opportunity. The FMECA identifies 29 potential failure modes for the router including erroneous LED indications, faulty switches, faulty fans, shorts, data bit errors, electrical overstress, data word failures, failure to operate at prescribed times, opens, and faulty components. It analyzes the effects of each failure mode on the router and higher level systems. The related federal contract opportunity is a draft request for proposal for the Integrated Battle Command System hardware low rate initial production and full rate production. It involves producing IBCS hardware in accordance with technical data packages and specifications, maintaining approved software and firmware updates, and executing any engineering changes for obsolescence, new capabilities, or export considerations. The solicitation number is W31P4Q-20-R-0015 and it is issued by the Department of the Army Materiel Command Contracting Command at Redstone Arsenal.
View the file
Other files for this federal contract opportunity
Show all 50
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet2
| Row Labels | Sum of Cm | Count of Failure Mode Description |
| Erroneous LED indication | 4.83E-05 | 7 |
| Faulty Switch | 3.45E-05 | 6 |
| Faulty Fan | 2.87E-05 | 5 |
| Short | 6.90E-06 | 3 |
| Data bit error | 4.60E-06 | 2 |
| Electrical Overstress | 1.15E-06 | 1 |
| Data word failure | 1.15E-06 | 1 |
| Failure to operate at a prescribed time | 1.15E-06 | 1 |
| Open | 1.15E-06 | 1 |
| Faulty Component | 1.15E-06 | 1 |
| Under/over voltage | 1.15E-06 | 1 |
| Grand Total | 1.30E-04 | 29 |
Prelim Analysis
| Major End Item: | Shelter - Router and Switches | |||
| Parent LRU: | E063-Isolation Router (Blk) | |||
| Component: | ISOLATION ROUTER - BLK (A318) | |||
| Mission Phase-Operational Mode: | All Phases | |||
| Cr = ∑Cm = | 1.30E-04 | |||
| Failure Modes | Count of | |||
| Failure Modes | Severity Classifications | Count of |
Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes
| Erroneous LED indication | 7 | 24.14% | Category III | 26 | Erroneous LED indication | 4.83E-05 | 7 |
| Faulty Switch | 6 | 20.69% | Erroneous LED indication | 6 | Faulty Switch | 3.45E-05 | 6 |
| Faulty Fan | 5 | 17.24% | Faulty Switch | 5 | Faulty Fan | 2.87E-05 | 5 |
| Short | 3 | 10.34% | Faulty Fan | 5 | Short | 6.90E-06 | 3 |
| Data bit error | 2 | 6.90% | Short | 2 | Data bit error | 4.60E-06 | 2 |
| Electrical Overstress | 1 | 3.45% | Data bit error | 2 | Electrical Overstress | 1.15E-06 | 1 |
| Data word failure | 1 | 3.45% | Electrical Overstress | 1 | Data word failure | 1.15E-06 | 1 |
| Failure to operate at a prescribed time | 1 | 3.45% | Data word failure | 1 | Failure to operate at a prescribed time | 1.15E-06 | 1 |
| Open | 1 | 3.45% | Failure to operate at a prescribed time | 1 | Open | 1.15E-06 | 1 |
| Faulty Component | 1 | 3.45% | Open | 1 | Faulty Component | 1.15E-06 | 1 |
| Under/over voltage | 1 | 3.45% | Faulty Component | 1 | Under/over voltage | 1.15E-06 | 1 |
| Grand Total | 29 | Under/over voltage | 1 | Grand Total | 1.30E-04 | 29 | |
| Category IV | 3 | ||||||
| Short | 1 | ||||||
| Erroneous LED indication | 1 | ||||||
| Faulty Switch | 1 | ||||||
| Grand Total | 29 |
Cat I and Cat II No Category I and Category II Classifications
E063 Data
| Major End Item: | Shelter - Router and Switches | ||||||||||||||||||||
| Parent LRU: | E063-Isolation Router (Blk) | ||||||||||||||||||||
| Component: | ISOLATION ROUTER - BLK (A318) | ||||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | ||||||||||||||||||||
| FPMH: | 9.258 | ||||||||||||||||||||
| t: | 72 | hr | |||||||||||||||||||
| Cr = ∑Cm = | 1.30E-04 | ||||||||||||||||||||
| Modified Cr = | 1.30E-04 | ||||||||||||||||||||
| No Category I and Category II Classifications | |||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compensating Provisions | |||||||||||||||||||
| ID# | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||||||||
| Consideration | Safety | ||||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | ||||||||||||||||||
| Capabilities | Seveverity | ||||||||||||||||||||
| Classification | Alternate Design | ||||||||||||||||||||
| Modifications | Modified Severity | ||||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | |||||||||||||||
| 2005 | Common Cause Events | Faulty Component | Hardware Failure | Component Inoperative | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 3.45E-02 | 9.26E-06 | 1.15E-06 | 1.15E-06 | |
| 2006 | Power & Power Distribution. | Failure to operate at a prescribed time | Hardware Failure | Loss of regulated DC power | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 3.45E-02 | 9.26E-06 | 1.15E-06 | 1.15E-06 | |
| 2007 | Power & Power Distribution. | Under/over voltage | Hardware Failure | Loss of regulated DC power | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 3.45E-02 | 9.26E-06 | 1.15E-06 | 1.15E-06 | |
| 2008 | Power & Power Distribution. | Short | Hardware Failure | Loss of regulated DC power | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | Shelter CB-22 TRIPS | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 1.03E-01 | 9.26E-06 | 3.45E-06 | 3.45E-06 | |
| 2009 | Power Switch | Faulty Switch | Hardware Failure | Switch opens early/unexpectedly | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.07E-01 | 9.26E-06 | 6.90E-06 | 6.90E-06 | |
| 2010 | Power Switch | Faulty Switch | Hardware Failure | Switch opens early/unexpectedly | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.07E-01 | 9.26E-06 | 6.90E-06 | 6.90E-06 | |
| 2011 | Power Switch | Faulty Switch | Hardware Failure | Switch opens early/unexpectedly | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.07E-01 | 9.26E-06 | 6.90E-06 | 6.90E-06 | |
| 2012 | Power Switch | Faulty Switch | Hardware Failure | Switch opens late or not at all when required | Loss of ability to remove power when required | Corrective maintenance required. | N/A | N/A | N/A | N/A | TBD | Category IV | EOCs are Redundant | Category IV | 0.00 | 0.00 | 2.07E-01 | 9.26E-06 | 0.00E+00 | 0.00E+00 | |
| 2013 | Power Switch | Faulty Switch | Hardware Failure | Switch opens early/unexpectedly | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.07E-01 | 9.26E-06 | 6.90E-06 | 6.90E-06 | |
| 2014 | Power Switch | Faulty Switch | Hardware Failure | Switch opens early/unexpectedly | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.07E-01 | 9.26E-06 | 6.90E-06 | 6.90E-06 | |
| 2015 | Power Switch | Short | Hardware Failure | Switch opens late or not at all when required | Loss of ability to remove power when required | Corrective maintenance required. | N/A | N/A | N/A | N/A | TBD | Category IV | EOCs are Redundant | Category IV | 0.00 | 0.00 | 1.03E-01 | 9.26E-06 | 0.00E+00 | 0.00E+00 | |
| 2016 | Switch cooling | Faulty Fan | Hardware Failure | Degraded air movement by fan assembly. | Possible Loss of WIN-T Black Data due to elevated interior temperatures | Possible Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 1.72E-01 | 9.26E-06 | 5.75E-06 | 5.75E-06 | |
| 2017 | Switch cooling | Faulty Fan | Hardware Failure | Degraded air movement by fan assembly. | Possible Loss of WIN-T Black Data due to elevated interior temperatures | Possible Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 1.72E-01 | 9.26E-06 | 5.75E-06 | 5.75E-06 | |
| 2018 | Switch cooling | Faulty Fan | Hardware Failure | Degraded air movement by fan assembly. | Possible Loss of WIN-T Black Data due to elevated interior temperatures | Possible Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 1.72E-01 | 9.26E-06 | 5.75E-06 | 5.75E-06 | |
| 2019 | Switch cooling | Faulty Fan | Hardware Failure | Degraded air movement by fan assembly. | Possible Loss of WIN-T Black Data due to elevated interior temperatures | Possible Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 1.72E-01 | 9.26E-06 | 5.75E-06 | 5.75E-06 | |
| 2020 | Switch cooling | Faulty Fan | Hardware Failure | Degraded air movement by fan assembly. | Possible Loss of WIN-T Black Data due to elevated interior temperatures | Possible Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 1.72E-01 | 9.26E-06 | 5.75E-06 | 5.75E-06 | |
| 2021 | LEDs | Erroneous LED indication | Hardware Failure | Loss of LED brightness | No Effect | No Effect | N/A | N/A | N/A | N/A | TBD | Category IV | EOCs are Redundant | Category IV | 0.00 | 0.00 | 2.41E-01 | 9.26E-06 | 0.00E+00 | 0.00E+00 | |
| 2022 | LEDs | Erroneous LED indication | Hardware Failure | Loss of LED | Erroneous indication | Possible delay in starting a mission | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.41E-01 | 9.26E-06 | 8.05E-06 | 8.05E-06 | |
| 2023 | LEDs | Erroneous LED indication | Hardware Failure | Loss of LED | Erroneous indication | Possible delay in starting a mission | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.41E-01 | 9.26E-06 | 8.05E-06 | 8.05E-06 | |
| 2024 | LEDs | Erroneous LED indication | Hardware Failure | Loss of LED | Erroneous indication | Possible delay in starting a mission | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.41E-01 | 9.26E-06 | 8.05E-06 | 8.05E-06 | |
| 2025 | LEDs | Erroneous LED indication | Hardware Failure | Loss of LED | Erroneous indication | Possible delay in starting a mission | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.41E-01 | 9.26E-06 | 8.05E-06 | 8.05E-06 | |
| 2026 | LEDs | Erroneous LED indication | Hardware Failure | Loss of LED | Erroneous indication | Possible delay in starting a mission | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.41E-01 | 9.26E-06 | 8.05E-06 | 8.05E-06 | |
| 2027 | LEDs | Erroneous LED indication | Hardware Failure | Loss of LED | Erroneous indication | Possible delay in starting a mission | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 2.41E-01 | 9.26E-06 | 8.05E-06 | 8.05E-06 | |
| 2028 | NIPR DATA | Open | Hardware Failure | No data throughput | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | OB-540-80 | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 3.45E-02 | 9.26E-06 | 1.15E-06 | 1.15E-06 | |
| 2029 | NIPR DATA | Electrical Overstress | Hardware Failure | Possible loss of data throughput | Possible Loss of WIN-T Black Data | Possible Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | OB-540-80 | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 3.45E-02 | 9.26E-06 | 1.15E-06 | 1.15E-06 | |
| 2030 | NIPR DATA | Data bit error | Software error (design defect) | Spurious data transmitted | Possible Loss of WIN-T Black Data | Possible Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | OB-540-80 | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 6.90E-02 | 9.26E-06 | 2.30E-06 | 2.30E-06 | |
| 2031 | NIPR DATA | Short | Hardware Failure | Unreadable data streaming | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | OB-540-80 | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 1.03E-01 | 9.26E-06 | 3.45E-06 | 3.45E-06 | |
| 2032 | NIPR DATA | Data bit error | Hardware Failure | Unreadable data streaming | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | OB-540-80 | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 6.90E-02 | 9.26E-06 | 2.30E-06 | 2.30E-06 | |
| 2033 | NIPR DATA | Data word failure | Software error (design defect) | Unreadable data streaming | Loss of WIN-T Black Data | Degraded Mission due to Loss of WIN-T Blk Data | N/A | N/A | OB-540-80 | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 3.45E-02 | 9.26E-06 | 1.15E-06 | 1.15E-06 |