Attachment 10b.3 – E005 Blower Assembly-FMECA.xlsx

XLSX spreadsheet 33 KB Posted

Attached to
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document contains a Failure Modes and Effects Criticality Analysis (FMECA) for the blower assembly component of an emergency operations center (EOC) shelter.

The FMECA identifies six potential failure modes for the blower assembly: binding/sticking, inoperative, improper output, will not engage, and no current. It analyzes the effects of each failure mode at the component, equipment, and system level. Though failures could potentially result in hazardous carbon monoxide accumulation, several compensating provisions make this an extremely remote risk, including non-occupancy of the shelter, status indicators, and pre-use testing. The document recommends maintaining a Severity Classification of II. It evaluates potential design modifications to further reduce risk.

The related federal contract opportunity is a draft request for proposal for low-rate initial production and full-rate production of the Integrated Battle Command System hardware. It involves maintaining approved updates and authority to operate on existing hardware, as well as engineering changes, for an Army Materiel Command requirement. Vendors are not to submit proposals in response to the draft RFP.

View the file

Other files for this federal contract opportunity

Other files attached to DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
Attachment 21 - Task Order 0001 Statement of Work.docx DOCX document
Attachment 10c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 10a.16– R034 Media Converter Power Supply-FMECA.xlsx XLSX spreadsheet
W31P4Q-20-R-0015_DRAFT_28 May 2020.pdf PDF
Attachment 10a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 04b - Draft_Relay Acceptance Test Procedures.docx DOCX document
Attachment 13c - IBCS-A301-003 Vol II Instructor Guide.pdf PDF
Attachment 22a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 22a.1.d - ALH-213030 00 CABLE ASSEMBLY, CASS J1 AND J3.pdf PDF
Attachment 10a.14 – R032 Media Converter Module 11-FMECA.xlsx XLSX spreadsheet
Attachment 20 - Section M - Evaluation Factors For Award.docx DOCX document
Attachment 22a - CASS to PDRS.docx DOCX document
Attachment 10d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10e.10 – E148 – Table 4 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10e.5 – E122 – EMI Tent PDU-FMECA.xlsx XLSX spreadsheet
Attachment 17 - Pre-Award Survey Accounting System Checklist.pdf PDF
Attachment 22a.1.g - PL-ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 22a.1.e - ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 22a.4 - CASS Task Purpose.pptx PPTX presentation
Attachment 10a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 10c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 03 - GFP Attachment - LRIP_FRP - 20 April 2020.xlsx XLSX spreadsheet
Attachment 22a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 15b - Fixed Price Level of Effort Labor Categories.xlsx XLSX spreadsheet
Attachment 10h - SWFMEA RESULTS.xlsx XLSX spreadsheet
Attachment 22a.1.h - PL-ALH-211130 00 CABLE ASSEMBLY CASS DC POWER.pdf PDF
Attachment 04c - ECT_Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 22a.1.a - ALH-208670 05 IBCS SHELTER INTERCONNECT.pdf PDF
Attachment 10a.4 – R004 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 13 - Training Documentation.docx DOCX document
Attachment 10a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.j - PL-ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 10c.5 – E050 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 10b.9 – E033 R112 Shelter – Server Stack – 03-FMECA.xlsx XLSX spreadsheet
Attachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 10a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 19 - Section L - Instructions - Conditions - And Notices To Offerors.docx DOCX document
Attachment 10c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 10e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.b - ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 10c.1 – E043 Firewall Red-FMECA.xlsx XLSX spreadsheet
Attachment 02 - AIAMD System of Systems (SoS)(MIS-PRF-56500).pdf PDF
Attachment 10b.1 – E001 28VDC Pwr Supply Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10e.11 – E149 – Table 5 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10d.2 – E144 RWS Bkup Batteries-FMECA.xlsx XLSX spreadsheet
Attachment 12 - Risk Management Plan.pdf PDF
Attachment 04 - Acceptance Test Plan.docx DOCX document
Attachment 10c.13 – E063 Isolation Router Black-FMECA.xlsx XLSX spreadsheet
Show all 50

DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet2

Row LabelsSum of CmCount of Failure Mode Description
Binding/Sticking1.08E-041
Improper Output1.08E-041
Inoperative4.31E-042
No Current1.08E-041
Will Not Engage1.08E-041
Grand Total8.61E-046

Prelim Analysis

PRELIMINARY ANALYSIS:Major End Item:Shelter - ECU
Parent LRU:E005-Blower Assembly
Component:Blower (Not Critical)
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =8.61E-04
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Inoperative233.33%Category II6Inoperative4.31E-042
Binding/Sticking116.67%Inoperative2Binding/Sticking1.08E-041
Improper Output116.67%Binding/Sticking1Improper Output1.08E-041
No Current116.67%Improper Output1No Current1.08E-041
Will Not Engage116.67%No Current1Will Not Engage1.08E-041
Grand Total6Will Not Engage1Grand Total8.61E-046
Grand Total6

Cat I and II

Major End Item:Shelter - ECU
Parent LRU:E005-Blower Assembly
Componet:Blower (Not Critical)
Mission Phase-Operational Mode:All Phases
FPMH:35.9454
t:72
Cr = ∑Cm =8.61E-04
Modified Cr =1.73E-04(Redundancy)
Due to the remote chance of hazard levels CO the Severity Classifications will remain at Severity Classification II
Failure Effect atFailure Detection MethodCompemsating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
85The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Binding/StickingHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.16673.59E-051.08E-042.16E-05
86The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.33333.59E-052.15E-044.31E-05
87The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Improper OutputHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.16673.59E-051.08E-042.16E-05
88The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.33333.59E-052.15E-044.31E-05
89The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Will Not EngageHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.16673.59E-051.08E-042.16E-05
90The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.No CurrentHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 N/A TBD Category II EOCs are Redundant Category III-2R 0.50 0.05 0.1667 3.59E-05 1.08E-04 2.16E-05

E005 Data

Major End Item:Shelter - ECU
Parent LRU:E005-Blower Assembly
Componet:Blower (Not Critical)
Mission Phase-Operational Mode:All Phases
FPMH:35.9454
t:72
Cr = ∑Cm =1.72E-03
Modified Cr =1.73E-04(Redundancy)
Due to the remote chance of hazard levels CO the Severity Classifications will remain at Severity Classification II
Failure Effect atFailure Detection MethdCompemsating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
85The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Binding/StickingHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.16673.59E-052.15E-042.16E-05
86The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.33333.59E-054.31E-044.31E-05
87The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Improper OutputHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.16673.59E-052.15E-042.16E-05
88The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.33333.59E-054.31E-044.31E-05
89The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Will Not EngageHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.16673.59E-052.15E-042.16E-05
90The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.No CurrentHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and Light Indication N/A TBD Category I EOCs are Redundant Category III-1R 1.00 0.05 0.1667 3.59E-05 2.15E-04 2.16E-05

Sheet1