Attachment 10a.4 – R004 IGRM-FMECA.xlsx

XLSX spreadsheet 96 KB Posted

Attached to
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document contains a draft request for proposal for the Integrated Battle Command System (IBCS) Low Rate Initial Production/Full Rate Production hardware segment. The Army Materiel Command Contracting Command at Redstone Arsenal is seeking to produce IBCS hardware end items in accordance with supplied technical data packages and the Critical Item Development Specification. Engineering changes may be required for obsolescence, new capabilities, and export considerations. The requirement includes maintaining approved software and firmware updates, cybersecurity, authority to operate, and engineering changes on existing hardware components. Proposers should not submit a proposal in response to this draft RFP, as the government is not currently seeking proposals based on the information provided.

View the file

Other files for this federal contract opportunity

Other files attached to DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
Attachment 21 - Task Order 0001 Statement of Work.docx DOCX document
Attachment 10c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 10a.16– R034 Media Converter Power Supply-FMECA.xlsx XLSX spreadsheet
W31P4Q-20-R-0015_DRAFT_28 May 2020.pdf PDF
Attachment 10a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 04b - Draft_Relay Acceptance Test Procedures.docx DOCX document
Attachment 13c - IBCS-A301-003 Vol II Instructor Guide.pdf PDF
Attachment 22a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 22a.1.d - ALH-213030 00 CABLE ASSEMBLY, CASS J1 AND J3.pdf PDF
Attachment 10a.14 – R032 Media Converter Module 11-FMECA.xlsx XLSX spreadsheet
Attachment 20 - Section M - Evaluation Factors For Award.docx DOCX document
Attachment 22a - CASS to PDRS.docx DOCX document
Attachment 10d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10e.10 – E148 – Table 4 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10e.5 – E122 – EMI Tent PDU-FMECA.xlsx XLSX spreadsheet
Attachment 17 - Pre-Award Survey Accounting System Checklist.pdf PDF
Attachment 22a.1.g - PL-ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 22a.1.e - ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 22a.4 - CASS Task Purpose.pptx PPTX presentation
Attachment 10a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 10c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 03 - GFP Attachment - LRIP_FRP - 20 April 2020.xlsx XLSX spreadsheet
Attachment 22a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 15b - Fixed Price Level of Effort Labor Categories.xlsx XLSX spreadsheet
Attachment 10h - SWFMEA RESULTS.xlsx XLSX spreadsheet
Attachment 22a.1.h - PL-ALH-211130 00 CABLE ASSEMBLY CASS DC POWER.pdf PDF
Attachment 04c - ECT_Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 22a.1.a - ALH-208670 05 IBCS SHELTER INTERCONNECT.pdf PDF
Attachment 13 - Training Documentation.docx DOCX document
Attachment 10a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.j - PL-ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 10c.5 – E050 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 10b.9 – E033 R112 Shelter – Server Stack – 03-FMECA.xlsx XLSX spreadsheet
Attachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 10a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 19 - Section L - Instructions - Conditions - And Notices To Offerors.docx DOCX document
Attachment 10c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 10e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.b - ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 10c.1 – E043 Firewall Red-FMECA.xlsx XLSX spreadsheet
Attachment 02 - AIAMD System of Systems (SoS)(MIS-PRF-56500).pdf PDF
Attachment 10b.1 – E001 28VDC Pwr Supply Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10e.11 – E149 – Table 5 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10d.2 – E144 RWS Bkup Batteries-FMECA.xlsx XLSX spreadsheet
Attachment 12 - Risk Management Plan.pdf PDF
Attachment 04 - Acceptance Test Plan.docx DOCX document
Attachment 10c.13 – E063 Isolation Router Black-FMECA.xlsx XLSX spreadsheet
Attachment 10b.8 – E032 R112 Shelter – Server Stack – 02-FMECA.xlsx XLSX spreadsheet
Show all 50

DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Row LabelsSum of CmCount of Failure Mode Description
Opened1.24E-0240
Shorted9.84E-0334
Intermittent operation8.03E-0347
Failure to Operate (Timing)1.09E-0310
Loss of output or failure during operations1.09E-0310
Faulty Component3.78E-046
Failed2.34E-0413
Degraded output or operational capability2.18E-049
Premature Operation (Timing)1.05E-049
Premature Operation (Zeroize)8.09E-053
Failure to receive/send data within 10 minutes of BPU power-up7.19E-052
Workmanship5.66E-053
Failure to switch Timing Sources3.60E-052
Failure to Cease Operation (Timing)2.16E-058
Premature Operation (Location Source)8.99E-061
Faulty Output8.99E-061
Loose8.09E-063
Grand Total3.37E-02201

Prelim Analysis

Parent LRU:R004-IGRM
Component:Chassis Assembly
IGRM GPS Receiver Board
IGRM Processor Board
IGRM Power Supply Board
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =8.09E-06
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Intermittent operation4723.38%Category I11Opened1.24E-0240
Opened4019.90%Failure to Operate (Timing)3Shorted9.84E-0334
Shorted3416.92%Loss of output or failure during operations3Intermittent operation8.03E-0347
Failed136.47%Failure to receive/send data ≤ 10 min. of BPU power-up2Failure to Operate (Timing)1.09E-0310
Failure to Operate (Timing)104.98%Opened1Loss of output or failure during operations1.09E-0310
Loss of output or failure during operations104.98%Faulty Component1Faulty Component3.78E-046
Premature Operation (Timing)94.48%Shorted1Failed2.34E-0413
Degraded output or operational capability94.48%Category II35Degraded output or operational capability2.18E-049
Failure to Cease Operation (Timing)83.98%Opened15Premature Operation (Timing)1.05E-049
Faulty Component62.99%Shorted9Premature Operation (Zeroize)8.09E-053
Loose31.49%Faulty Component3Failure to receive/send data ≤ 10 min of BPU power-up7.19E-052
Workmanship31.49%Failure to Operate (Timing)2Workmanship5.66E-053
Premature Operation (Zeroize)31.49%Failed2Failure to switch Timing Sources3.60E-052
Failure to receive/send data ≤ 10 min. of BPU power-up21.00%Loss of output or failure during operations2Failure to Cease Operation (Timing)2.16E-058
Failure to switch Timing Sources21.00%Premature Operation (Timing)1Premature Operation (Location Source)8.99E-061
Premature Operation (Location Source)10.50%Workmanship1Faulty Output8.99E-061
Faulty Output10.50%Category III6Loose8.09E-063
Grand Total201Intermittent operation3Grand Total:3.37E-02201
Opened1
Shorted1
Loose1
Category IV149
Intermittent operation44
Opened23
Shorted23
Failed11
Degraded output or operational capability9
Premature Operation (Timing)8
Failure to Cease Operation (Timing)8
Failure to Operate (Timing)5
Loss of output or failure during operations5
Premature Operation (Zeroize)3
Failure to switch Timing Sources2
Loose2
Faulty Component2
Workmanship2
Faulty Output1
Premature Operation (Location Source)1
Grand Total:201

Cat I and Cat II

Parent LRU:R004-IGRMID#
Component:Chassis Assembly254-379
IGRM GPS Receiver Board380-410
IGRM Processor Board411-449
IGRM Power Supply Board450-460
Mission Phase-Operational Mode:All Phases
FPMH:50.2040
t:72
Cr = ∑Cm =3.41E-02
Modified Cm =4.79E-03
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R or Severity Classification III-2R
Failure Effect atFailure Detection MethodsCompemsating Provisions
ID#SubcomponentComponentFunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator
ObservationVisual
IndicationsC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
254IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – 1PPS UTC Time Pulse Source SelectionPremature Operation (Timing)Software defectFunction operates early/ unexpectedlyIGRM Mux switches to backup timing sourceLoss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04480.0000502048.09E-058.09E-06
255IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – 1PPS UTC Time Pulse Source SelectionFailure to Operate (Timing)Software defectFunction operates late or not at allIGRM Mux not directed to switch to backup timing sourceLoss of network communicationN/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.04980.0000502041.80E-048.99E-06
257IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – 1PPS UTC Time Pulse Source SelectionFailure to switch Timing SourcesSoftware defectIGRM continues to use backup data sourceLoss of redundancy. For total loss of function, impending loss of network communication.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.01000.0000502041.80E-051.80E-06
258IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – 1PPS UTC Time Pulse Source SelectionLoss of output or failure during operationsSoftware defectLoss of functionIGRM Mux not directed to switch to backup timing sourceLoss of network communicationN/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.04980.0000502041.80E-048.99E-06
260IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – LocationPremature Operation (Location Source)Software defectFunction operates early/ unexpectedlyIGRM switches to backup location sourceLoss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.00500.0000502048.99E-068.99E-07
261IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – LocationFailure to Operate (Timing)Software defectFunction operates late or not at allIGRM cannot switch to backup location sourceLoss of network communicationN/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.04980.0000502041.80E-048.99E-06
264IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – LocationLoss of output or failure during operationsSoftware defectLoss of functionIGRM cannot switch to backup location sourceLoss of network communicationN/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.04980.0000502041.80E-048.99E-06
267IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – Output to HNRFailure to Operate (Timing)Software defectFunction operates late or not at allImpending loss of network communicationImpending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
268IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – Output to HNRIntermittent operationSoftware defectFunction degradedProbable impending loss of network communicationProbable impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
270IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – Output to HNRLoss of output or failure during operationsSoftware defectLoss of functionImpending loss of network communicationImpending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
271IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – Output to HNRFaulty OutputSoftware defectFunction degradedProbable impending loss of network communicationProbable impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.00500.0000502048.99E-068.99E-07
273IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – InitializationFailure to Operate (Timing)Software defectFunction operates late or not at allImpending loss of network communicationImpending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
274IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – InitializationIntermittent operationSoftware defectFunction degradedProbable impending loss of network communicationProbable impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
276IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – InitializationLoss of output or failure during operationsSoftware defectLoss of functionImpending loss of network communicationImpending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
277IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – InitializationDegraded output or operational capabilitySoftware defectFunction degradedPossible impending loss of network communicationPossible impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04480.0000502048.09E-058.09E-06
278IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – Common cause failuresFailedSoftware defectLoss of functionImpending loss of network communicationImpending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.06470.0000502041.17E-041.17E-05
279IGRM SoftwareR004-01-IGRM Chassis AssemblyNG Radio Kit Custom Software – Dependent failure that affects all similar software modulesFailedSoftware defectLoss of functionImpending loss of network communicationImpending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.06470.0000502041.17E-041.17E-05
280IGRM MuxR004-01-IGRM Chassis AssemblyConnector A - Primary input from GPSShortedHardware failureData connection shorted resulting in loss of communicationLoss of redundancy. For total loss of function, impending loss of network communication.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
281IGRM MuxR004-01-IGRM Chassis AssemblyConnector A - Primary input from GPSOpenedHardware failureNo throughputLoss of redundancy. For total loss of function, impending loss of network communication.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
283IGRM MuxR004-01-IGRM Chassis AssemblyConnector B – Secondary input from external 1PPSShortedHardware failureData connection shorted resulting in loss of communicationLoss of redundancy. For total loss of function, impending loss of network communication.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
284IGRM MuxR004-01-IGRM Chassis AssemblyConnector B – Secondary input from external 1PPSOpenedHardware failureNo throughputLoss of redundancy. For total loss of function, impending loss of network communication.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
286IGRM MuxR004-01-IGRM Chassis AssemblyConnector Y_ - Inverse output to provide SBC with notification when 1PPS is generatedShortedHardware failureData connection shorted resulting in loss of communicationLoss of redundancy. For total loss of function, impending loss of network communication.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
287IGRM MuxR004-01-IGRM Chassis AssemblyConnector Y_ - Inverse output to provide SBC with notification when 1PPS is generatedOpenedHardware failureNo throughputLoss of redundancy. For total loss of function, impending loss of network communication.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
291IGRM MuxR004-01-IGRM Chassis AssemblyMain power inputShortedHardware failurePower shorted resulting in possible damage to components or tripping of circuit breakerImpending loss of network communicationImpending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
292IGRM MuxR004-01-IGRM Chassis AssemblyMain power inputOpenedHardware failureNo throughputImpending loss of network communicationImpending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
293IGRM MuxR004-01-IGRM Chassis AssemblyMain power inputIntermittent operationHardware failureIntermittent continuityProbable impending loss of network communicationProbable impending loss of network communicationN/AN/AN/AVI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
294IGRM MuxR004-01-IGRM Chassis AssemblyMain power returnOpenedHardware failureNo throughputImpending loss of network communicationImpending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
295IGRM MuxR004-01-IGRM Chassis AssemblyMain power returnIntermittent operationHardware failureIntermittent continuityProbable impending loss of network communicationProbable impending loss of network communicationN/AN/AN/AVI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
297IGRM MuxR004-01-IGRM Chassis AssemblyConnector A_/B – Control line to select outputFailure to Operate (Timing)Hardware failureFunction operates late or not at allLoss of redundancy. For total loss of function, impending loss of network communication.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
298IGRM MuxR004-01-IGRM Chassis AssemblyConnector A_/B – Control line to select outputIntermittent operationHardware failureFunction degradedProbable loss of redundancy. For total loss of function, impending loss of network communication.Probable loss of redundancy. For total loss of function, impending loss of network communication.N/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
299IGRM MuxR004-01-IGRM Chassis AssemblyConnector A_/B – Control line to select outputFailure to switch Timing SourcesHardware failureIGRM continues to use backup data sourceLoss of redundancy. For total loss of function, impending loss of network communication.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.01000.0000502041.80E-051.80E-06
300IGRM MuxR004-01-IGRM Chassis AssemblyConnector A_/B – Control line to select outputLoss of output or failure during operationsHardware failureLoss of functionLoss of redundancy. For total loss of function, impending loss of network communication.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
301IGRM MuxR004-01-IGRM Chassis AssemblyConnector A_/B – Control line to select outputDegraded output or operational capabilityHardware failureFunction degradedProbable loss of redundancy. For total loss of function, impending loss of network communication.Probable loss of redundancy. For total loss of function, impending loss of network communication.N/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04480.0000502048.09E-058.09E-06
302IGRM MuxR004-01-IGRM Chassis AssemblyConnector Y – 1PPS outputShortedHardware failureData connection shorted resulting in loss of communicationImpending loss of network communicationImpending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
303IGRM MuxR004-01-IGRM Chassis AssemblyConnector Y – 1PPS outputOpenedHardware failureNo throughputImpending loss of network communicationImpending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
304IGRM MuxR004-01-IGRM Chassis AssemblyConnector Y – 1PPS outputIntermittent operationHardware failureIntermittent continuityProbable impending loss of network communicationProbable impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
305IGRM MuxR004-01-IGRM Chassis AssemblyCommon Cause Events - Timing source selectionFaulty ComponentHardware failureComponent inoperativeImpending loss of network communicationImpending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.02990.0000502045.40E-055.40E-06
306I/O Panel (USB)R004-01-IGRM Chassis AssemblyUSB 0 - Initialization Data Load (J5)OpenedHardware failureNo throughputAssuming mission dictates update of initialization parameters (conservative), impending loss of network communicationImpending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
307I/O Panel (USB)R004-01-IGRM Chassis AssemblyUSB 0 - Initialization Data Load (J5)ShortedHardware failureData connection shorted resulting in loss of communicationAssuming mission dictates update of initialization parameters (conservative), impending loss of network communicationImpending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
308I/O Panel (USB)R004-01-IGRM Chassis AssemblyUSB 0 - Initialization Data Load (J5)Intermittent operationHardware failureIntermittent continuityAssuming mission dictates update of initialization parameters (conservative), possible impending loss of network communicationPossible impending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
313I/O Panel (DB)R004-01-IGRM Chassis AssemblyCOM 2 - GPS NMEA Serial (J6, pins 2, 3)ShortedHardware failureData connection shorted resulting in loss of communicationBPU cannot perform dynamic key changes without TOD input. Impending IFCN Relay failure.Impending loss of network communicationN/AN/AOB-625-10N/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
314I/O Panel (DB)R004-01-IGRM Chassis AssemblyCOM 2 - GPS NMEA Serial (J6, pins 2, 3)OpenedHardware failureNo throughputBPU cannot perform dynamic key changes without TOD input. Impending IFCN Relay failure.Impending loss of network communicationN/AN/AOB-625-10N/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
315I/O Panel (DB)R004-01-IGRM Chassis AssemblyCOM 2 - GPS NMEA Serial (J6, pins 2, 3)Intermittent operationHardware failureIntermittent continuityBPU cannot perform dynamic key changes without TOD input. Possible impending IFCN Relay failure.Possible impending loss of network communicationN/AN/AOB-625-10N/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
316I/O Panel (DB)R004-01-IGRM Chassis AssemblyCOM 2 - GPS NMEA Serial (J6, pins 2, 3)Failure to receive/send data ≤ 10 min. of BPU power-upHardware failureBPU cannot properly initializeIFCN Relay inoperativeLoss of network communicationN/AN/AOB-625-10N/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.01000.0000502043.60E-051.80E-06
319I/O Panel (Ethernet)R004-01-IGRM Chassis AssemblyEthernet Interface with IGRM (J22) – Receive ControlOpenedHardware failureNo throughputIFCN Relay inoperativeLoss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IRelays are RedundantCategory III-1R1.000.050.19900.0000502047.19E-043.60E-05
321I/O Panel (Ethernet)R004-01-IGRM Chassis AssemblyEthernet Interface with IGRM (J22) – Receive ControlShortedHardware failureData connection shorted resulting in loss of communicationIFCN Relay inoperativeLoss of network communicationN/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.16920.0000502046.11E-043.06E-05
325I/O Panel (Ethernet)R004-01-IGRM Chassis AssemblyEthernet Interface with IGRM (J22)Faulty ComponentHardware failureComponent inoperativeIFCN Relay inoperativeLoss of network communicationN/AN/AN/AN/ATBDCategory IRelays are RedundantCategory III-1R1.000.050.02990.0000502041.08E-045.40E-06
326I/O Panel (Power)R004-01-IGRM Chassis Assembly28 VDC Power Input to IGRM (J24) - Power (pins 1 through 6)OpenedHardware failureLoss of continuityIGRM cannot provide data to BPUImpending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
327I/O Panel (Power)R004-01-IGRM Chassis Assembly28 VDC Power Input to IGRM (J24) - Power (pins 1 through 6)Intermittent operationHardware failureIntermittent continuityIGRM possibly cannot provide data to BPUPossible impending loss of network communicationN/AN/AN/AVI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
328I/O Panel (Power)R004-01-IGRM Chassis Assembly28 VDC Power Input to IGRM (J24) - Power (pins 1 through 6)ShortedHardware failurePower shorted resulting in possible tripping of IGRM circuit breakerPossible impending loss of network communicationPossible impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
330I/O Panel (Power)R004-01-IGRM Chassis Assembly28 VDC Power Input to IGRM (J24)Faulty ComponentHardware failureComponent inoperativeImpending loss of network communicationImpending loss of network communicationN/AN/AN/AVI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.02990.0000502045.40E-055.40E-06
331I/O Panel (RF)R004-01-IGRM Chassis AssemblyGPS RF (J100)OpenedHardware failureIGRM cannot process GPS input.GPS data unavailable.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
333I/O Panel (RF)R004-01-IGRM Chassis AssemblyGPS RF (J100)ShortedHardware failureData connection shorted resulting in loss of communicationGPS data unavailable.Loss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
334I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 3 - SCIM RS232 (J8) - Location from SCIM to IGRMOpenedHardware failureNo throughputLoss of manual input of locationLoss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
336I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 3 - SCIM RS232 (J8) - Location from SCIM to IGRMShortedHardware failureData connection shorted resulting in loss of communicationLoss of manual input of locationLoss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
340I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 4 – BDDP Serial (J9)ShortedHardware failureData connection shorted resulting in loss of communicationIGRM Mux switches to backup data sourceLoss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
341I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 4 – BDDP Serial (J9)OpenedHardware failureNo throughputIGRM Mux switches to backup data sourceLoss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
343I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 5 – Multi Function (J30) – GPS TimingOpenedHardware failureNo throughputIGRM Mux switches to backup data sourceLoss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-05 (Relay SCIM Message-GPS 1PPS Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
345I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 5 – Multi Function (J30) – GPS TimingShortedHardware failureData connection shorted resulting in loss of communicationIGRM Mux switches to backup data sourceLoss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-05 (Relay SCIM Message-GPS 1PPS Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
346I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 5 – Multi Function (J30) – GPS DataShortedHardware failureData connection shorted resulting in loss of communicationIGRM Mux switches to backup data sourceLoss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
347I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 5 – Multi Function (J30) – GPS DataOpenedHardware failureNo throughputIGRM Mux switches to backup data sourceLoss of redundancy: For total loss of function, impending loss of network communication.N/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
349I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 5 – Multi Function (J30) – SCIM PowerShortedHardware failurePower shorted resulting in possible tripping of IGRM circuit breakerIFCN Relay possibly inoperativePossible impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
350I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 5 – Multi Function (J30) – SCIM PowerOpenedHardware failureNo throughputSCIM inoperableLoss of redundancy: For total loss of function, impending loss of network communication. Loss of diagnostic capability through SCIM.N/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
354I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 6 – GPS Fill/Zeroize (J26) – GPS ZeroizePremature Operation (Zeroize)Hardware failureFunction operates early/ unexpectedlyInadvertently erased crypto data and navigational information stored in the GRAM.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-08 (Relay SCIM Message-HNR Crypto Key Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.01490.0000502042.70E-052.70E-06
355I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 6 – GPS Fill/Zeroize (J26) – GPS FillOpenedHardware failureNo throughputUnable to load cryptographic keysIn the event of cryptographic key updates, loss of redundancyN/AN/AOB-625-10N/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
357I/O Panel (DB, GPS)R004-01-IGRM Chassis AssemblyCOM 6 – GPS Fill/Zeroize (J26) – GPS FillShortedHardware failureData connection shorted resulting in loss of communicationUnable to load cryptographic keysIn the event of cryptographic key updates, loss of redundancyN/AN/AOB-625-10N/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
360Cable Assembly, GPS Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - KEYFILL/ 5 VDC Out – GPS ZeroizePremature Operation (Zeroize)Hardware failureFunction operates early/ unexpectedlyInadvertently erased crypto data and navigational information stored in the GRAM.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-08 (Relay SCIM Message-HNR Crypto Key Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.01490.0000502042.70E-052.70E-06
362Cable Assembly, GPS Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - KEYFILL/ 5 VDC Out – GPS FillOpenedHardware failureNo throughputUnable to load cryptographic keysIn the event of cryptographic key updates, loss of redundancyN/AN/AOB-625-10N/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
364Cable Assembly, GPS Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - KEYFILL/ 5 VDC Out – GPS FillShortedHardware failureData connection shorted resulting in loss of communicationUnable to load cryptographic keysIn the event of cryptographic key updates, loss of redundancyN/AN/AOB-625-10N/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
365Cable Assembly, GPS Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - KEYFILL/ 5 VDC Out – GPS FillWorkmanshipManufacturing defectNo throughputUnable to load cryptographic keysIn the event of cryptographic key updates, loss of redundancyN/AN/AOB-625-10N/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.01490.0000502042.70E-052.70E-06
366Cable Assembly, GPS Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - GPS Input to GB-GRAMOpenedHardware failureIGRM cannot process GPS input.GPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
368Cable Assembly, GPS Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - GPS Input to GB-GRAMShortedHardware failureData connection shorted resulting in loss of communicationGPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
369Cable Assembly, GPS Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - GPS Input to GB-GRAMWorkmanshipManufacturing defectIGRM cannot process GPS input.GPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.01490.0000502042.70E-052.70E-06
370Cable Assembly, Power Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - 28VDC Input from I/O Panel Board to P/SOpenedHardware failureLoss of continuityIGRM cannot provide data to BPUImpending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
371Cable Assembly, Power Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - 28VDC Input from I/O Panel Board to P/SIntermittent operationHardware failureIntermittent continuityIGRM possibly cannot provide data to BPUPossible impending loss of network communicationN/AN/AN/AVI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
372Cable Assembly, Power Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - 28VDC Input from I/O Panel Board to P/SShortedHardware failurePower shorted resulting in possible tripping of IGRM circuit breakerPossible impending loss of network communicationPossible impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
373Cable Assembly, Power Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - Input Voltage Switch Bypass JumperOpenedHardware failureLoss of continuityIGRM cannot provide data to BPUImpending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
374Cable Assembly, Power Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - Input Voltage Switch Bypass JumperIntermittent operationHardware failureIntermittent continuityIGRM possibly cannot provide data to BPUPossible impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
375Cable Assembly, Power Internal to IGRMR004-01-IGRM Chassis AssemblyInternal IGRM Cable - Input Voltage Switch Bypass JumperShortedHardware failurePower shorted resulting in possible tripping of IGRM circuit breakerPossible impending loss of network communicationPossible impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
380IGRM Carrier CardR004-02-IGRM GPS Receiver Board+5 VDC Pwr Input (P11)OpenedHardware failureIGRM cannot process GPS input.GPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
382IGRM Carrier CardR004-02-IGRM GPS Receiver Board+5 VDC Pwr Input (P11)ShortedHardware failurePower shorted resulting in possible tripping of IGRM circuit breakerIFCN Relay possibly inoperativePossible impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
383IGRM Carrier CardR004-02-IGRM GPS Receiver BoardConnector P3 - GPS BDDP Serial Data (pins 3, 5)OpenedHardware failureCarrier Card cannot send GPS data to SBC.GPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
385IGRM Carrier CardR004-02-IGRM GPS Receiver BoardConnector P3 - GPS BDDP Serial Data (pins 3, 5)ShortedHardware failureData connection shorted resulting in loss of communicationGPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
388IGRM Carrier CardR004-02-IGRM GPS Receiver BoardConnector P3 - GPS Zeroize (pins 7, 9)Premature Operation (Zeroize)Hardware failureFunction operates early/ unexpectedlyInadvertently erased crypto data and navigational information stored in the GRAM.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-08 (Relay SCIM Message-HNR Crypto Key Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.01490.0000502042.70E-052.70E-06
389IGRM Carrier CardR004-02-IGRM GPS Receiver BoardConnector P3 – 1PPS Out (pin 10)OpenedHardware failureNo throughputGPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-05 (Relay SCIM Message-GPS 1PPS Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
391IGRM Carrier CardR004-02-IGRM GPS Receiver BoardConnector P3 – 1PPS Out (pin 10)ShortedHardware failureData connection shorted resulting in loss of communicationGPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
393IGRM Carrier CardR004-02-IGRM GPS Receiver BoardConnector P7 – KeyfillOpenedHardware failureNo throughputUnable to load cryptographic keysIn the event of cryptographic key updates, loss of redundancyN/AN/AOB-625-10N/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
395IGRM Carrier CardR004-02-IGRM GPS Receiver BoardConnector P7 – KeyfillShortedHardware failureData connection shorted resulting in loss of communicationUnable to load cryptographic keysIn the event of cryptographic key updates, loss of redundancyN/AN/AOB-625-10N/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
396IGRM Carrier CardR004-02-IGRM GPS Receiver BoardSMT Connector for GRAMOpenedHardware failureIGRM cannot process GPS input.GPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
397IGRM Carrier CardR004-02-IGRM GPS Receiver BoardSMT Connector for GRAMIntermittent operationHardware failureIGRM possibly cannot process GPS input.GPS data possibly unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
398IGRM Carrier CardR004-02-IGRM GPS Receiver BoardSMT Connector for GRAMShortedHardware failureData connection shorted resulting in loss of communicationGPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
400IGRM Carrier CardR004-02-IGRM GPS Receiver BoardCarrier CardFaulty ComponentHardware failureIGRM cannot process GPS input.GPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.02990.0000502045.40E-055.40E-06
401IGRM GPS Receiver Application Module (GRAM)R004-02-IGRM GPS Receiver Board+3.3 VDC Pwr InputOpenedHardware failureIGRM cannot process GPS input.GPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
403IGRM GPS Receiver Application Module (GRAM)R004-02-IGRM GPS Receiver Board+3.3 VDC Pwr InputShortedHardware failurePower shorted resulting in possible tripping of IGRM circuit breakerIFCN Relay possibly inoperativePossible impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
404IGRM GPS Receiver Application Module (GRAM)R004-02-IGRM GPS Receiver BoardSMT Connector for Interface with Carrier CardOpenedHardware failureIGRM cannot process GPS input.GPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
406IGRM GPS Receiver Application Module (GRAM)R004-02-IGRM GPS Receiver BoardSMT Connector for Interface with Carrier CardShortedHardware failureData connection shorted resulting in loss of communicationGPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
407IGRM GPS Receiver Application Module (GRAM)R004-02-IGRM GPS Receiver BoardGPS RF InputOpenedHardware failureIGRM cannot process GPS input.GPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
409IGRM GPS Receiver Application Module (GRAM)R004-02-IGRM GPS Receiver BoardGPS RF InputShortedHardware failureData connection shorted resulting in loss of communicationGPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
410IGRM GPS Receiver Application Module (GRAM)R004-02-IGRM GPS Receiver BoardCarrier CardFaulty ComponentHardware failureIGRM cannot process GPS input.GPS data unavailable.Loss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.02990.0000502045.40E-055.40E-06
411IGRM Single Board ComputerR004-03-IGRM Processor BoardPower InputOpenedHardware failureNo throughputIGRM cannot provide data to BPUImpending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.19900.0000502043.60E-043.60E-05
412IGRM Single Board ComputerR004-03-IGRM Processor BoardPower InputIntermittent operationHardware failureIntermittent continuityIGRM possibly cannot provide data to BPUPossible impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.23380.0000502044.23E-044.23E-05
413IGRM Single Board ComputerR004-03-IGRM Processor BoardPower InputShortedHardware failurePower shorted resulting in possible tripping of IGRM circuit breakerIGRM possibly cannot provide data to BPUPossible impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.16920.0000502043.06E-043.06E-05
415IGRM Single Board ComputerR004-03-IGRM Processor BoardSerial Interface to SCIMFailure to Operate (Timing)Hardware failure or software defectFunction operates late or not at allOperator unable to input location or perform diagnostics at the SCIMLoss of redundancy: for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
418IGRM Single Board ComputerR004-03-IGRM Processor BoardSerial Interface to SCIMLoss of output or failure during operationsHardware failure or software defectLoss of functionOperator unable to input location or perform diagnostics at the SCIMLoss of redundancy: for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
421IGRM Single Board ComputerR004-03-IGRM Processor BoardNMEA (Serial) Interface to GRAMFailure to Operate (Timing)Hardware failure or software defectFunction operates late or not at allLoss of Location and TOD data from GPSLoss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-11 (Relay SCIM Message-GPS Location Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
424IGRM Single Board ComputerR004-03-IGRM Processor BoardNMEA (Serial) Interface to GRAMLoss of output or failure during operationsHardware failure or software defectLoss of functionLoss of Location and TOD data from GPSLoss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
427IGRM Single Board ComputerR004-03-IGRM Processor BoardControl Interface to MuxFailure to Operate (Timing)Hardware failure or software defectFunction operates late or not at allIGRM Mux cannot switch to backup timing sourceLoss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AVI-625-05 (Relay SCIM Message-GPS 1PPS Reported Fault)TBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06
430IGRM Single Board ComputerR004-03-IGRM Processor BoardControl Interface to MuxLoss of output or failure during operationsHardware failure or software defectLoss of functionIGRM Mux cannot switch to backup timing sourceLoss of redundancy: for total loss of function, impending loss of network communicationN/AN/AN/AN/ATBDCategory IIRelays are RedundantCategory III-2R0.500.050.04980.0000502048.99E-058.99E-06