Attachment 10a.10 – R016 thru R025 Media Converter Module-FMECA.xlsx

XLSX spreadsheet 42 KB Posted

Attached to
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP
Solicitation number
W31P4Q-20-R-0015
Issued by

About this file

This document contains a Federal Acquisition Regulation (FAR) Part 15 draft request for proposal (RFP) for an Integrated Battle Command System (IBCS) hardware low rate initial production/full rate production effort. The Army Materiel Command Contracting Command at Redstone Arsenal is seeking to produce IBCS hardware end items such as media converter modules in accordance with supplied technical data packages and critical item development specifications. The effort requires maintaining approved software and firmware updates, cybersecurity, and authority to operate on existing hardware components, as well as engineering changes for obsolescence, new capabilities, and export considerations. The RFP notes this is a draft for comment only and is not currently seeking proposals.

View the file

Other files

File Type Posted
Attachment 10h - SWFMEA RESULTS.xlsx XLSX spreadsheet
Attachment 10a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10b.9 – E033 R112 Shelter – Server Stack – 03-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.a - ALH-208670 05 IBCS SHELTER INTERCONNECT.pdf PDF
Attachment 22a - CASS to PDRS.docx DOCX document
Attachment 10c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 10a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.c - ALH-211130 00 CABLE ASSEMBLY CASS DC POWER.pdf PDF
Attachment 20 - Section M - Evaluation Factors For Award.docx DOCX document
Attachment 10a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 10c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 10a.2 – R002 BPU-FMECAAttachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10g - IBCS - 243-003 HW FMECA Results.pdf PDF
Attachment 22a.3 - S280_SystemPowerAnalysis_Draft_12-5-2017.xlsx XLSX spreadsheet
Attachment 10c.12 – E062 Shelter Router-Red-FMECA.xlsx XLSX spreadsheet
Attachment 10c.14 – E064 Shelter Router Black – FMECA.xlsx XLSX spreadsheet
Attachment 10d.2 – E144 RWS Bkup Batteries-FMECA.xlsx XLSX spreadsheet
Attachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10c.5 – E050 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 10c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 10e.2 – E082 thru E091 Wkstn Laptop-FMECA.xlsx XLSX spreadsheet
Attachment 10d.4 – E151 – Media Converter 04-FMECA.xlsx XLSX spreadsheet
Attachment 10d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 13c - IBCS-A301-003 Vol II Instructor Guide.pdf PDF
Attachment 03 - GFP Attachment - LRIP_FRP - 20 April 2020.xlsx XLSX spreadsheet
Attachment 10a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 22a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 19 - Section L - Instructions - Conditions - And Notices To Offerors.docx DOCX document
Attachment 10c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.e - ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 04b - Draft_Relay Acceptance Test Procedures.docx DOCX document
Attachment 22a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 10c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 10b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA.xlsx XLSX spreadsheet
Attachment 16 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 13a -A293-004 ETM 60 Percent Draft.pdf PDF
Attachment 04a - Draft_EOC Acceptance Test Procedures.docx DOCX document
Attachment 10d.6 – E153 RS112 Server -05 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10e.1 – E067 – EtherNet Switch-FMECA.xlsx XLSX spreadsheet
Attachment 06 - Obsolete Parts List.pdf PDF
Attachment 04c - ECT_Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 15a- Example Skill Classification Crosswalk.xlsx XLSX spreadsheet
Attachment 10c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 10a.8 – R008 Media Converter Chassis-FMECA.xlsx XLSX spreadsheet
Attachment 10b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 21 - Task Order 0001 Statement of Work.docx DOCX document
Attachment 10a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.b - ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Show 40 more

Latest 50 of 98 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pivot Table

R016 thru R025 Media Converter Module
Row LabelsSum of CmCount of Failure Mode Description
Media Converter fails to process data2.69E-0410
Grand Total2.69E-0410

Prelim Analsis

PRELIMINARY ANALYSIS:Parent LRU:R016 thru R025 Media Converter Module (Indivdual)
Component:Media Converter Module
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =2.69E-04
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Media Converter fails to process data10100%Category II10Media Converter fails to process data2.69E-0410
Grand Total10Media Converter fails to process data10Grand Total2.69E-0410
Grand Total10

Cat I and Cat II

Parent LRU:R016 thru R025 Media Converter Module (Indivdual)
Component:Media Converter Module
Mission Phase-Operational Mode:All Phases
FPMH:1.540
t:72hr
Cr = ∑Cm =5.54E-04
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompemsating Provisions
ID#Parent LRUComponentFunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
1176R016-Media Converter Module #1Media Converter Module in Slot #1Relay Media Converter in Slot-1Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data" signal from User Platform #1Relay cannot connect to "Data" interface for User Platform #1Loss of communication/control for User Platform #1N/AN/AOB-640-10VI-640-10 (Loss of IFCN Relay Communications with Platform-1 Data)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1177R017-Media Converter Module #2Media Converter Module in Slot #2Relay Media Converter in Slot-2Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Voice" signal from User Platform #1Relay cannot connect to "Voice" interface for User Platform #1Loss of communication/control for User Platform #1N/AN/AOB-640-10VI-640-11 (Loss of IFCN Relay Communications with Platform-1 Voice)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1178R018-Media Converter Module #3Media Converter Module in Slot #3Relay Media Converter in Slot-3Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #2Relay cannot connect to "Data-1" interface for User Platform #2Loss of communication/control for User Platform #2N/AN/AOB-640-10VI-640-12 (Loss of IFCN Relay Communications with Platform-2 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1179R019-Media Converter Module #4Media Converter Module in Slot #4Relay Media Converter in Slot-4Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #2Relay cannot connect to "Data-2" interface for User Platform #2Loss of communication/control for User Platform #2N/AN/AOB-640-10VI-640-13 (Loss of IFCN Relay Communications with Platform-2 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1180R020-Media Converter Module #5Media Converter Module in Slot #5Relay Media Converter in Slot-5Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #3Relay cannot connect to "Data-1" interface for User Platform #3Loss of communication/control for User Platform #3N/AN/AOB-640-10VI-640-14 (Loss of IFCN Relay Communications with Platform-3 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1181R021-Media Converter Module #6Media Converter Module in Slot #6Relay Media Converter in Slot-6Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #3Relay cannot connect to "Data-2" interface for User Platform #3Loss of communication/control for User Platform #3N/AN/AOB-640-10VI-640-15 (Loss of IFCN Relay Communications with Platform-3 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1182R022-Media Converter Module #7Media Converter Module in Slot #7Relay Media Converter in Slot-7Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #4Relay cannot connect to "Data-1" interface for User Platform #4Loss of communication/control for User Platform #4N/AN/AOB-640-10VI-640-16 (Loss of IFCN Relay Communications with Platform-4 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1183R023-Media Converter Module #8Media Converter Module in Slot #8Relay Media Converter in Slot-8Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #4Relay cannot connect to "Data-2" interface for User Platform #4Loss of communication/control for User Platform #4N/AN/AOB-640-10VI-640-17 (Loss of IFCN Relay Communications with Platform-4 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1184R024-Media Converter Module #9Media Converter Module in Slot #9Relay Media Converter in Slot-9Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #5Relay cannot connect to "Data-1" interface for User Platform #5Loss of communication/control for User Platform #5N/AN/AOB-640-10VI-640-18 (Loss of IFCN Relay Communications with Platform-5 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1185R025-Media Converter Module #10Media Converter Module in Slot #10Relay Media Converter in Slot-10Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #6Relay cannot connect to "Data-1" interface for User Platform #6Loss of communication/control for User Platform #6N/AN/AOB-640-10VI-640-19 (Loss of IFCN Relay Communications with Platform-6 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06

R016 - R025 Data

Parent LRU:R016 thru R025 Media Converter Module (Indivdual)
Component:Media Converter Module
Mission Phase-Operational Mode:All Phases
FPMH:0.746
t:72hr
Cr = ∑Cm =2.69E-04
Modified Cr =2.69E-05
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompemsating Provisions
ID#Parent LRUComponentFunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
1176R016-Media Converter Module #1Media Converter Module in Slot #1Relay Media Converter in Slot-1Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data" signal from User Platform #1Relay cannot connect to "Data" interface for User Platform #1Loss of communication/control for User Platform #1N/AN/AOB-640-10VI-640-10 (Loss of IFCN Relay Communications with Platform-1 Data)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1177R017-Media Converter Module #2Media Converter Module in Slot #2Relay Media Converter in Slot-2Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Voice" signal from User Platform #1Relay cannot connect to "Voice" interface for User Platform #1Loss of communication/control for User Platform #1N/AN/AOB-640-10VI-640-11 (Loss of IFCN Relay Communications with Platform-1 Voice)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1178R018-Media Converter Module #3Media Converter Module in Slot #3Relay Media Converter in Slot-3Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #2Relay cannot connect to "Data-1" interface for User Platform #2Loss of communication/control for User Platform #2N/AN/AOB-640-10VI-640-12 (Loss of IFCN Relay Communications with Platform-2 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1179R019-Media Converter Module #4Media Converter Module in Slot #4Relay Media Converter in Slot-4Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #2Relay cannot connect to "Data-2" interface for User Platform #2Loss of communication/control for User Platform #2N/AN/AOB-640-10VI-640-13 (Loss of IFCN Relay Communications with Platform-2 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1180R020-Media Converter Module #5Media Converter Module in Slot #5Relay Media Converter in Slot-5Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #3Relay cannot connect to "Data-1" interface for User Platform #3Loss of communication/control for User Platform #3N/AN/AOB-640-10VI-640-14 (Loss of IFCN Relay Communications with Platform-3 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1181R021-Media Converter Module #6Media Converter Module in Slot #6Relay Media Converter in Slot-6Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #3Relay cannot connect to "Data-2" interface for User Platform #3Loss of communication/control for User Platform #3N/AN/AOB-640-10VI-640-15 (Loss of IFCN Relay Communications with Platform-3 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1182R022-Media Converter Module #7Media Converter Module in Slot #7Relay Media Converter in Slot-7Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #4Relay cannot connect to "Data-1" interface for User Platform #4Loss of communication/control for User Platform #4N/AN/AOB-640-10VI-640-16 (Loss of IFCN Relay Communications with Platform-4 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1183R023-Media Converter Module #8Media Converter Module in Slot #8Relay Media Converter in Slot-8Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #4Relay cannot connect to "Data-2" interface for User Platform #4Loss of communication/control for User Platform #4N/AN/AOB-640-10VI-640-17 (Loss of IFCN Relay Communications with Platform-4 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1184R024-Media Converter Module #9Media Converter Module in Slot #9Relay Media Converter in Slot-9Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #5Relay cannot connect to "Data-1" interface for User Platform #5Loss of communication/control for User Platform #5N/AN/AOB-640-10VI-640-18 (Loss of IFCN Relay Communications with Platform-5 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1185R025-Media Converter Module #10Media Converter Module in Slot #10Relay Media Converter in Slot-10Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #6Relay cannot connect to "Data-1" interface for User Platform #6Loss of communication/control for User Platform #6N/AN/AOB-640-10VI-640-19 (Loss of IFCN Relay Communications with Platform-6 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06

Sheet1

File details come from the government source that posted it. Updated .