Attachment 10a.10 – R016 thru R025 Media Converter Module-FMECA.xlsx
XLSX spreadsheet 42 KB Posted
- Attached to
- DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
- Solicitation number
- W31P4Q-20-R-0015
About this file
This document contains a Federal Acquisition Regulation (FAR) Part 15 draft request for proposal (RFP) for an Integrated Battle Command System (IBCS) hardware low rate initial production/full rate production effort. The Army Materiel Command Contracting Command at Redstone Arsenal is seeking to produce IBCS hardware end items such as media converter modules in accordance with supplied technical data packages and critical item development specifications. The effort requires maintaining approved software and firmware updates, cybersecurity, and authority to operate on existing hardware components, as well as engineering changes for obsolescence, new capabilities, and export considerations. The RFP notes this is a draft for comment only and is not currently seeking proposals.
View the file
Other files for this federal contract opportunity
Show all 50
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pivot Table
| R016 thru R025 Media Converter Module | ||
| Row Labels | Sum of Cm | Count of Failure Mode Description |
| Media Converter fails to process data | 2.69E-04 | 10 |
| Grand Total | 2.69E-04 | 10 |
Prelim Analsis
| PRELIMINARY ANALYSIS: | Parent LRU: | R016 thru R025 Media Converter Module (Indivdual) | |||
| Component: | Media Converter Module | ||||
| Mission Phase-Operational Mode: | All Phases | ||||
| Cr = ∑Cm = | 2.69E-04 | ||||
| Failure Modes | Count of | ||||
| Failure Modes | Severity | ||||
| Classifications | Count of |
Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes
| Media Converter fails to process data | 10 | 100% | Category II | 10 | Media Converter fails to process data | 2.69E-04 | 10 |
| Grand Total | 10 | Media Converter fails to process data | 10 | Grand Total | 2.69E-04 | 10 | |
| Grand Total | 10 |
Cat I and Cat II
| Parent LRU: | R016 thru R025 Media Converter Module (Indivdual) | ||||||||||||||||
| Component: | Media Converter Module | ||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | ||||||||||||||||
| FPMH: | 1.540 | ||||||||||||||||
| t: | 72 | hr | |||||||||||||||
| Cr = ∑Cm = | 5.54E-04 | ||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R | |||||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | |||||||||||||||
| ID# | Parent LRU | Component | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||
| Consideration | Safety | ||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | ||||||||||||||
| Capabilities | Severity | ||||||||||||||||
| Classification | Alternate Design | ||||||||||||||||
| Modifications | Modified Severity | ||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | |||||||||||
| 1176 | R016-Media Converter Module #1 | Media Converter Module in Slot #1 | Relay Media Converter in Slot-1 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data" signal from User Platform #1 | Relay cannot connect to "Data" interface for User Platform #1 | Loss of communication/control for User Platform #1 | N/A | N/A | OB-640-10 | VI-640-10 (Loss of IFCN Relay Communications with Platform-1 Data) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 1.5398E-06 | 5.54E-05 | 5.54E-06 |
| 1177 | R017-Media Converter Module #2 | Media Converter Module in Slot #2 | Relay Media Converter in Slot-2 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Voice" signal from User Platform #1 | Relay cannot connect to "Voice" interface for User Platform #1 | Loss of communication/control for User Platform #1 | N/A | N/A | OB-640-10 | VI-640-11 (Loss of IFCN Relay Communications with Platform-1 Voice) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 1.5398E-06 | 5.54E-05 | 5.54E-06 |
| 1178 | R018-Media Converter Module #3 | Media Converter Module in Slot #3 | Relay Media Converter in Slot-3 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-1" signal from User Platform #2 | Relay cannot connect to "Data-1" interface for User Platform #2 | Loss of communication/control for User Platform #2 | N/A | N/A | OB-640-10 | VI-640-12 (Loss of IFCN Relay Communications with Platform-2 Data-1) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 1.5398E-06 | 5.54E-05 | 5.54E-06 |
| 1179 | R019-Media Converter Module #4 | Media Converter Module in Slot #4 | Relay Media Converter in Slot-4 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-2" signal from User Platform #2 | Relay cannot connect to "Data-2" interface for User Platform #2 | Loss of communication/control for User Platform #2 | N/A | N/A | OB-640-10 | VI-640-13 (Loss of IFCN Relay Communications with Platform-2 Data-2) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 1.5398E-06 | 5.54E-05 | 5.54E-06 |
| 1180 | R020-Media Converter Module #5 | Media Converter Module in Slot #5 | Relay Media Converter in Slot-5 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-1" signal from User Platform #3 | Relay cannot connect to "Data-1" interface for User Platform #3 | Loss of communication/control for User Platform #3 | N/A | N/A | OB-640-10 | VI-640-14 (Loss of IFCN Relay Communications with Platform-3 Data-1) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 1.5398E-06 | 5.54E-05 | 5.54E-06 |
| 1181 | R021-Media Converter Module #6 | Media Converter Module in Slot #6 | Relay Media Converter in Slot-6 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-2" signal from User Platform #3 | Relay cannot connect to "Data-2" interface for User Platform #3 | Loss of communication/control for User Platform #3 | N/A | N/A | OB-640-10 | VI-640-15 (Loss of IFCN Relay Communications with Platform-3 Data-2) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 1.5398E-06 | 5.54E-05 | 5.54E-06 |
| 1182 | R022-Media Converter Module #7 | Media Converter Module in Slot #7 | Relay Media Converter in Slot-7 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-1" signal from User Platform #4 | Relay cannot connect to "Data-1" interface for User Platform #4 | Loss of communication/control for User Platform #4 | N/A | N/A | OB-640-10 | VI-640-16 (Loss of IFCN Relay Communications with Platform-4 Data-1) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 1.5398E-06 | 5.54E-05 | 5.54E-06 |
| 1183 | R023-Media Converter Module #8 | Media Converter Module in Slot #8 | Relay Media Converter in Slot-8 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-2" signal from User Platform #4 | Relay cannot connect to "Data-2" interface for User Platform #4 | Loss of communication/control for User Platform #4 | N/A | N/A | OB-640-10 | VI-640-17 (Loss of IFCN Relay Communications with Platform-4 Data-2) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 1.5398E-06 | 5.54E-05 | 5.54E-06 |
| 1184 | R024-Media Converter Module #9 | Media Converter Module in Slot #9 | Relay Media Converter in Slot-9 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-1" signal from User Platform #5 | Relay cannot connect to "Data-1" interface for User Platform #5 | Loss of communication/control for User Platform #5 | N/A | N/A | OB-640-10 | VI-640-18 (Loss of IFCN Relay Communications with Platform-5 Data-1) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 1.5398E-06 | 5.54E-05 | 5.54E-06 |
| 1185 | R025-Media Converter Module #10 | Media Converter Module in Slot #10 | Relay Media Converter in Slot-10 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-1" signal from User Platform #6 | Relay cannot connect to "Data-1" interface for User Platform #6 | Loss of communication/control for User Platform #6 | N/A | N/A | OB-640-10 | VI-640-19 (Loss of IFCN Relay Communications with Platform-6 Data-1) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 1.5398E-06 | 5.54E-05 | 5.54E-06 |
R016 - R025 Data
| Parent LRU: | R016 thru R025 Media Converter Module (Indivdual) | ||||||||||||||||
| Component: | Media Converter Module | ||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | ||||||||||||||||
| FPMH: | 0.746 | ||||||||||||||||
| t: | 72 | hr | |||||||||||||||
| Cr = ∑Cm = | 2.69E-04 | ||||||||||||||||
| Modified Cr = | 2.69E-05 | ||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R | |||||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | |||||||||||||||
| ID# | Parent LRU | Component | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||
| Consideration | Safety | ||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | ||||||||||||||
| Capabilities | Severity | ||||||||||||||||
| Classification | Alternate Design | ||||||||||||||||
| Modifications | Modified Severity | ||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | |||||||||||
| 1176 | R016-Media Converter Module #1 | Media Converter Module in Slot #1 | Relay Media Converter in Slot-1 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data" signal from User Platform #1 | Relay cannot connect to "Data" interface for User Platform #1 | Loss of communication/control for User Platform #1 | N/A | N/A | OB-640-10 | VI-640-10 (Loss of IFCN Relay Communications with Platform-1 Data) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 7.4630E-07 | 2.69E-05 | 2.69E-06 |
| 1177 | R017-Media Converter Module #2 | Media Converter Module in Slot #2 | Relay Media Converter in Slot-2 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Voice" signal from User Platform #1 | Relay cannot connect to "Voice" interface for User Platform #1 | Loss of communication/control for User Platform #1 | N/A | N/A | OB-640-10 | VI-640-11 (Loss of IFCN Relay Communications with Platform-1 Voice) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 7.4630E-07 | 2.69E-05 | 2.69E-06 |
| 1178 | R018-Media Converter Module #3 | Media Converter Module in Slot #3 | Relay Media Converter in Slot-3 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-1" signal from User Platform #2 | Relay cannot connect to "Data-1" interface for User Platform #2 | Loss of communication/control for User Platform #2 | N/A | N/A | OB-640-10 | VI-640-12 (Loss of IFCN Relay Communications with Platform-2 Data-1) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 7.4630E-07 | 2.69E-05 | 2.69E-06 |
| 1179 | R019-Media Converter Module #4 | Media Converter Module in Slot #4 | Relay Media Converter in Slot-4 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-2" signal from User Platform #2 | Relay cannot connect to "Data-2" interface for User Platform #2 | Loss of communication/control for User Platform #2 | N/A | N/A | OB-640-10 | VI-640-13 (Loss of IFCN Relay Communications with Platform-2 Data-2) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 7.4630E-07 | 2.69E-05 | 2.69E-06 |
| 1180 | R020-Media Converter Module #5 | Media Converter Module in Slot #5 | Relay Media Converter in Slot-5 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-1" signal from User Platform #3 | Relay cannot connect to "Data-1" interface for User Platform #3 | Loss of communication/control for User Platform #3 | N/A | N/A | OB-640-10 | VI-640-14 (Loss of IFCN Relay Communications with Platform-3 Data-1) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 7.4630E-07 | 2.69E-05 | 2.69E-06 |
| 1181 | R021-Media Converter Module #6 | Media Converter Module in Slot #6 | Relay Media Converter in Slot-6 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-2" signal from User Platform #3 | Relay cannot connect to "Data-2" interface for User Platform #3 | Loss of communication/control for User Platform #3 | N/A | N/A | OB-640-10 | VI-640-15 (Loss of IFCN Relay Communications with Platform-3 Data-2) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 7.4630E-07 | 2.69E-05 | 2.69E-06 |
| 1182 | R022-Media Converter Module #7 | Media Converter Module in Slot #7 | Relay Media Converter in Slot-7 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-1" signal from User Platform #4 | Relay cannot connect to "Data-1" interface for User Platform #4 | Loss of communication/control for User Platform #4 | N/A | N/A | OB-640-10 | VI-640-16 (Loss of IFCN Relay Communications with Platform-4 Data-1) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 7.4630E-07 | 2.69E-05 | 2.69E-06 |
| 1183 | R023-Media Converter Module #8 | Media Converter Module in Slot #8 | Relay Media Converter in Slot-8 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-2" signal from User Platform #4 | Relay cannot connect to "Data-2" interface for User Platform #4 | Loss of communication/control for User Platform #4 | N/A | N/A | OB-640-10 | VI-640-17 (Loss of IFCN Relay Communications with Platform-4 Data-2) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 7.4630E-07 | 2.69E-05 | 2.69E-06 |
| 1184 | R024-Media Converter Module #9 | Media Converter Module in Slot #9 | Relay Media Converter in Slot-9 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-1" signal from User Platform #5 | Relay cannot connect to "Data-1" interface for User Platform #5 | Loss of communication/control for User Platform #5 | N/A | N/A | OB-640-10 | VI-640-18 (Loss of IFCN Relay Communications with Platform-5 Data-1) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 7.4630E-07 | 2.69E-05 | 2.69E-06 |
| 1185 | R025-Media Converter Module #10 | Media Converter Module in Slot #10 | Relay Media Converter in Slot-10 | Media Converter fails to process data | Hardware | ||||||||||||
| Failure | Media Converter fails to process "Data-1" signal from User Platform #6 | Relay cannot connect to "Data-1" interface for User Platform #6 | Loss of communication/control for User Platform #6 | N/A | N/A | OB-640-10 | VI-640-19 (Loss of IFCN Relay Communications with Platform-6 Data-1) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 1.00 | 7.4630E-07 | 2.69E-05 | 2.69E-06 |