Attachment 10-Tab F - Tech Lib 20230725.pdf
PDF 48 MB Posted
- Attached to
- Base Operational Services - Grissom ARB IN Federal contract opportunity
- Solicitation number
- FA4654-23-R0006
About this file
This document appears to be an attachment to a solicitation for base operational services at Grissom Air Reserve Base in Indiana. The solicitation was issued by the Department of the Air Force Reserve Command under number FA4654-23-R0006. It seeks proposals from contractors to provide various operational support services at the base, including facility maintenance and repair, transportation, equipment operation, and supply services. Proposals are due by July 25, 2023, and the contract award is expected in late 2023. Small businesses, including HUBZone, 8(a), woman-owned, and veteran-owned small businesses, are encouraged to compete. The period of performance will be a one year base period with four one-year options to extend. Pricing should be fixed for the base period but may be adjusted annually for the option periods.
View the file
Other files for this federal contract opportunity
Show all 40
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
Table of Contents
F-TE-2 Workload Estimates
F-TE-2a Corrective Maintenance and Modernization/Revitalization
F-TE-2b RSMeans Estimates
F-TE-2c AF Form 103 Work Clearance Form
F-TE-2d NexGen IT Work Load Estimates
F-TE-2e Builder Facility Condition Assessments
F-TE-2f Reserve Training
F-TE-2g Facilities Requiring Pest Management Inspections
F-TE-2h Ice Buckets and Utility Hydrant Stakes
F-TE-2i Facilities to be Maintained by the Contractor
F-TE-2j Grounds Maintenance
F-TE-2k Pavement Clearance Consumable Estimates (Sweeper & Snow Removal)
F-TE-2l High Mast Lighting
F-TE-2m Key Cutting
F-TE-2a
TOC
F-TE-2 Work Load Estimates
F-TE-2a. Corrective Maintenance (CM) and Modernization/Revitalization (M/R).
FY19-21 Totals Work Priority Data
Priority 1 3A 3B 3C 4A Total WT
Craft HRS # WT HRS # WT HRS # WT HRS # WT HRS # WT HRS # WT
CARPENTER 0 0 74.5 10 359 14 2158 78 0 0 2591.5 102
ELECTRICIAN 0.5 1 28 13 41 16 235.3 72 0 0 304.8 102
ENTOMOLOGY 0 0 26 18 204.5 39 3276.3 463 0 0 3506.8 520
EQUIP OPERATOR 5 2 220.5 24 647.3 53 12505.7 529 0 0 13378.5 608
EXT ELECT 44.5 8 1128.3 507 78.5 17 1311 309 0 0 2562.3 841
FIRE ALARM MECH 39 8 737.5 280 44 12 559.5 216 0 0 1380 516
GARDENER 0 0 0 0 0 0 18.5 4 0 0 18.5 4
GEN MAINT WKR 19 3 648.4 222 558.9 117 5991.3 1400 4.5 2 7222.1 1744
GROUNDS MAINT WKR 0 0 6 1 89 13 1851 88 0 0 1946 102
HEAVY EQUIP OP 0 0 0 0 71 3 1466.5 72 0 0 1537.5 75
HVAC MECH 22.5 9 1233 307 434 97 2930.1 722 0 0 4619.6 1135
INT ELECT 19.5 11 592 70 230 37 3231.8 722 42.5 8 4115.8 848
LABORER 5 4 807 61 1145 83 11490.2 709 6 3 13453.2 860
LIQUID FUELS 5 3 56 10 18.5 2 801.5 120 0 0 881 135
LOCKSMITH 7 4 56.5 34 62 32 1282.5 716 0 0 1408 786
PAINTER 0 0 5 1 60 6 1139.5 146 5 3 1209.5 156
PAVEMENT MAINT WKR 0 0 15.5 1 0 0 58 12 0 0 73.5 13
PIPEFITTER 0 0 305 10 168 3 1090.5 39 0 0 1563.5 52
PLUMBER 43 11 375.5 125 116 27 1916.5 573 4 1 2455 737
ROOFER 0 0 59.5 1 11 1 81.5 3 0 0 152 5
SHEETMETAL 0 0 4 1 54.5 9 121 5 0 0 179.5 15
SIGN MAKER 0 0 11 2 54 12 263.5 43 0 0 328.5 57
SPRINKLER FITTER 0 0 3 1 0 0 79.5 3 0 0 82.5 4
TRACTOR OPERATOR 0 0 0 0 26 5 464.5 49 0 0 490.5 54
TRUCK DRIVER 0 0 0 0 0 0 1130.8 50 0 0 1130.8 50
WELDER 0 0 0 0 0 0 10.5 3 0 0 10.5 3
Grand Total 210 64 6392.2 1699 4472.2 598 55465 7146 62 17 66601.4 9524
FY21 Work Priority Data
Priority 1 3A 3B 3C FY21 Totals
Craft HRS # WT HRS # WT HRS # WT HRS # WT HRS # WT
CARPENTER 7 3 166 6 672.5 26 845.5 35
ELECTRICIAN 27 12 2 1 149.5 44 178.5 57
ENTOMOLOGY 7.5 4 62.5 8 975 144 1045 156
EQUIP OPERATOR 85.5 10 179.5 16 5313 191 5578 217
EXT ELECT 36 5 408.5 168 45.5 8 383 75 873 256
FIRE ALARM MECH 9.5 4 304 118 21.5 3 125.5 43 460.5 168
GARDENER 2 1 2 1
GEN MAINT WKR 269.4 81 212.2 40 1799.4 419 2281 540
GROUNDS MAINT WKR 0 2 1119 55 1119 57
HEAVY EQUIP OP 62.5 2 15 3 77.5 5
HVAC MECH 17 8 637.5 154 153 31 735.5 163 1543 356
INT ELECT 9.5 5 120.5 31 62 16 773.5 193 965.5 245
LABORER 157.5 18 222 25 2486.5 198 2866 241
LIQUID FUELS 1 1 21 5 18.5 2 315 39 355.5 47
LOCKSMITH 26.5 14 11.5 6 475 210 513 230
PAINTER 20 3 174 28 194 31
PAVEMENT MAINT WKR 19 3 19 3
PIPEFITTER 159.5 3 136 2 116.5 5 412 10
PLUMBER 6 2 174.5 52 69.5 17 610 160 860 231
ROOFER 4 1 4 1
SHEETMETAL 4 1 4 6 121 5 129 12
SIGN MAKER 3 1 14 2 130 16 147 19
SPRINKLER FITTER 3 1 71.5 1 74.5 2
TRACTOR OPERATOR 15.5 3 395 34 410.5 37
TRUCK DRIVER 111.5 15 111.5 15
WELDER 10.5 3 10.5 3
Grand Total 79 25 2415.9 676 1477.7 199 17102.4 2075 21075 2975
FY20 Work Priority Data
Priority 1 3A 3B 3C FY20 Totals
Craft HRS # WT HRS # WT HRS # WT HRS # WT HRS # WT
CARPENTER 37 6 183 6 881 28 1101 40
ELECTRICIAN 0.5 1 36.5 11 59.5 14 96.5 26
ENTOMOLOGY 18.5 14 112.5 23 1361 165 1492 202
EQUIP OPERATOR 4 1 98 6 353.5 19 3510.6 147 3966.1 173
EXT ELECT 2.5 1 345 145 21 4 403 106 771.5 256
FIRE ALARM MECH 361 130 8 4 131 51 500 185
GARDENER 10.5 2 10.5 2
GEN MAINT WKR 4 1 166.5 54 241.7 41 2146 424 2558.2 520
GROUNDS MAINT WKR 6 1 47.5 6 539 27 592.5 34
HEAVY EQUIP OP 410 12 410 12
HVAC MECH 5.5 1 516.5 128 149 36 961.3 242 1632.3 407
INT ELECT 10 4 395.5 27 156.5 16 1218.5 236 1780.5 283
LABORER 506.5 33 646.5 35 4264.1 226 5417.1 294
LIQUID FUELS 7 2 220.5 38 227.5 40
LOCKSMITH 2.5 2 23.5 11 34 11 337.5 227 397.5 251
PAINTER 5 1 40 3 521.5 58 566.5 62
PAVEMENT MAINT WKR 15.5 1 20 5 35.5 6
PIPEFITTER 145.5 7 580 18 725.5 25
PLUMBER 5.5 4 148.5 48 41 9 677 193 872 254
ROOFER 45.5 1 45.5 1
SHEETMETAL 50.5 3 50.5 3
SIGN MAKER 8 1 71 10 79 11
SPRINKLER FITTER 8 2 8 2
TRACTOR OPERATOR 2.5 1 54.5 12 57 13
TRUCK DRIVER 424.3 11 424.3 11
WELDER
Grand Total 34.5 15 2803.5 615 2123.7 228 18855.3 2255 23817 3113
FY19 Work Priority Data
Priority 1 3A 3B 3C 4A FY19 Totals
Craft HRS # WT HRS # WT HRS # WT HRS # WT HRS # WT HRS # WT
CARPENTER 30.5 1 10 2 604.5 24 645 27
ELECTRICIAN 1 1 2.5 4 26.3 14 29.8 19
ENTOMOLOGY 29.5 8 940.3 154 969.8 162
EQUIP OPERATOR 1 1 37 8 114.3 18 3682.1 191 3834.4 218
EXT ELECT 6 2 374.8 194 12 5 525 128 917.8 329
FIRE ALARM MECH 29.5 4 72.5 32 14.5 5 303 122 419.5 163
GARDENER 6 1 6 1
GEN MAINT WKR 15 2 212.5 87 105 36 2045.9 557 4.5 2 2382.9 684
GROUNDS MAINT WKR 41.5 5 193 6 234.5 11
HEAVY EQUIP OP 8.5 1 1041.5 57 1050 58
HVAC MECH 79 25 132 30 1233.3 317 1444.3 372
INT ELECT 0 2 76 12 11.5 5 1239.8 293 42.5 8 1369.8 320
LABORER 5 4 143 10 276.5 23 4739.6 285 6 3 5170.1 325
LIQUID FUELS 4 2 28 3 266 43 298 48
LOCKSMITH 4.5 2 6.5 9 16.5 15 470 279 497.5 305
PAINTER 444 60 5 3 449 63
PAVEMENT MAINT WKR 19 4 19 4
PIPEFITTER 32 1 394 16 426 17
PLUMBER 31.5 5 52.5 25 5.5 1 629.5 220 4 1 723 252
ROOFER 59.5 1 11 1 32 1 102.5 3
SHEETMETAL
SIGN MAKER 40 10 62.5 17 102.5 27
SPRINKLER FITTER
TRACTOR OPERATOR 8 1 15 3 23 4
TRUCK DRIVER 595 24 595 24
WELDER
Grand Total 96.5 24 1172.8 408 870.8 171 19507.3 2816 62 17 21709.4 3436
F-TE-2b
TOC
F-TE-2b. RSMEANS Estimates.
CM CALLS M/R WORK
Average 12 Month Average 12 Month
Per Month Total Per Month Total
F-TE-2c
TOC
F-TE-2c.
AF 103, Work Clearance Form, Estimates: 60 annually
F-TE-2d
F-TE-2d. NexGen IT Work Load Estimates. TOC
NexGen IT PM Build
The Niagara Modified PM1 Report and the Niagara Building Equipment Report are available upon request. The Niagara Modified PM1 Report is from BUILDER. Assets names may have changed based on current naming conventions, and the report is a snap shot in time. The data may have changed after the report was pulled as the system is continuously updated. The Youngstown Modified PM1 Report is for reference only.
The Equipment Report is pulled from NGIT and reflects the equipment that migrated from BUILDER.
Create PM Program In NexGen IT Count
BEAR* migrated from BUILDER into NGIT** 2188
* Building Equipment Asset Record (BEAR): Associates a piece of equipment with a facility. Migrated information saves 3-5 minutes of typing versus creating a BEAR.
** Includes equipment not listed in F-TE-2 and F-TE-6, thus not part of this contract
70% - Avg of 3 frequencies roughly 200 hours* 20% - 1 frequencies- roughly 25 hours* 10% - 6 frequencies- roughly 75 hours* Note: *This is just an estimate, there are several variables in which these times can change
It is estimated to take 90 hours to create 100 additional Job Plans**
** For new eqiupment or equipment that didn't migrate from BUILDER
F-TE-2e
F-TE-2e Facility Condition Assessments: TOC
Annual Facility Condition Assessments (FCA) (F5.2.3) – Estimated 100,000 sq ft per day, based on a crew of five technicians familiar/proficient with their craft/discipline (carpenter, electrician, HAVC, plumber and fire alarms) and BUILDER. Square footage is listed in the F-TE-2i, Facilities To Be Maintained.
A Homestead Modified PM1 Report available upon request. The report is from BUILDER. Assets names may have changed based on current naming conventions, and the report is a snap shot in time. The data may have changed after the report was pulled as the system is continuously updated. The Homestead Modified PM1 Report is for reference only.
Section Categories to be Assessed and Inventoried
System - Description Section Category Definition
B20 EXTERIOR ENCLOSURE EXTERIOR WALLS All materials associated with the following construction: exterior load-bearing walls, insulation and vapor barrier, parapets, exterior louvers and screens, sun control devices (exterior), balcony walls and handrails, exterior soffits, screen walls, and exterior coatings.
B20 EXTERIOR ENCLOSURE B201006 BALCONY WALLS & HANDRAILS Fixed ladders
B20 EXTERIOR ENCLOSURE EXTERIOR DOORS All doors located in exterior walls or exterior skin.
B20 EXTERIOR ENCLOSURE B203004 OVERHEAD AND ROLL- UP DOORS Overhead and roll-up doors installed in exterior walls or exterior skin. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door. (Electrical or manual)
| B20 EXTERIOR ENCLOSURE | B203005 | HANGAR | |
| DOORS | Large aircraft doors used on medium and |
high bay hangars. Assemblies would include frames, hardware, hoisting devices, and finish and other associated work.
B20 EXTERIOR ENCLOSURE B203006 BLAST RESISTANT DOORS Special exterior doors used for blast resistance. Assemblies would include frames, hardware, hoisting devices, and finish and other associated work. Igloo/Blast, Hinged/Sliding
B30 ROOFING ROOF COVERINGS This system includes all waterproof roof coverings and insulation, expansion joints, together with skylights, hatches, ventilators, and all required trim. In addition to roof coverings, the system includes all waterproof membranes and traffic toppings over below grade enclosed areas, balconies and the like.
B30 ROOFING B301001 STEEP SLOPE ROOF SYSTEM Assemblies include roof coverings such as shingle, wood shake, structural standing seam, metal roofing, tile etc.
B30 ROOFING B301002 LOW SLOPE ROOF SYSTEMS Assemblies include roof coverings such as built-up, elastomeric, modified bitumen, polyurethane foam, single ply membranes, etc. Also, walkways and work areas will be included here.
B30 ROOFING B301005 GUTTERS & DOWNSPOUTS Assemblies include all gutters, downspouts, and associated works including splash blocks
B30 ROOFING B301006 ROOF OPENINGS AND SUPPORTS All roof penetrations including roof hatches, sky lights, area glazing, gravity roof ventilators, smoke vents, etc.for Munitions Storage facilities only.
B30 ROOFING B301090 OTHER ROOFING Roof ing not described by the assembly categories listed above including berms over flat roofed and barrel roof munitions storage facilities.
C10 INT CONSTRUCTION INTERIOR DOORS All interior doors.
C10 INT CONSTRUCTION C102003 FIRE DOORS Assemblies include all interior fire doors, including all necessary frames, and sensing devices integral with the door. Interior door hardware is located in C102007 INTERIOR DOOR HARDWARE.
C10 INT CONSTRUCTION C102005 INTERIOR OVERHEAD DOORS Overhead doors installed in the interior of a facility. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door.
C10 INT CONSTRUCTION C102090 OTHER INTERIOR SPECIALTY Any special type door installed in the interior of a facility. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit measure at the assembly level is each gate.
C10 INT CONSTRUCTION C103090 OTHER INTERIOR SPECIALTY Fixed Ladders
D10 CONVEYING ELEVATORS AND LIFTS This system includes personnel and equipment moving equipment such as elevators, and lifts, both hydraulic and electric
D10 CONVEYING D101002 PASSENGER ELEVATORS Assemblies include car, hoistway, machine room.
D10 CONVEYING D101003 FREIGHT ELEVATORS Assemblies include car, hoistway, machine room.
D10 CONVEYING D101004 WHEELCHAIR LIFTS Assemblies includes all associated equipment
D10 CONVEYING WEIGHT HANDLING EQUIPMENT This system includes built-in material lifting devices such as overhead cranes and monorails.
D10 CONVEYING D102001 OVERHEAD CRANES Assemblies includes all associated equipment
D10 CONVEYING D102003 MONORAILS Assemblies includes all associated equipment
D10 CONVEYING ESCALATORS AND MOVING WALKWAYS This system includes escalators used to move personnel vertically and moving walkways used to move horizontally.
D10 CONVEYING D103001 ESCALATORS Assemblies includes all associated equipment
D20 PLUMBING DOMESTIC WATER DISTRIBUTION This system provides for human health and comfort. The water supply needed is determined by the number of fixtures attached. Hot water heaters and special equipment are not counted as a fixture.
D20 PLUMBING D202002 BACKFLOW PREVENTERS This equipment prevents possibly contaminated / stagnant fire or mechanical system water from flowing back into potable water systems.
D20 PLUMBING D202003 DOMESTIC WATER EQUIPMENT This assembly includes equipment associated with the domestic water supply, including fittings, and specialties required for hook-up. Assemblies include hot water heaters and water treatment components; pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly level is each.
| D30 HVAC | HEAT GENERATING | |
| SYSTEMS | This subsystem includes steam, hot water, furnace, and unit heater systems. Fuels include coal, oil, gas and electric unless otherwise noted. |
D30 HVAC D302001 BOILERS Assemblies include steam or hot water boilers, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc. This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system.
D30 HVAC D302002 FURNACES This is a system that heats air. Assemblies would include furnace and necessary fittings and specialties required for hook-up, including flue and stack. The unit of measure at the assembly level is each.
D30 HVAC D302003 FUEL-FIRED UNIT HEATERS Assemblies would include unit heaters and the energy supply system hook-up (other than electrical), including all necessary pipe, fittings, and specialties required for hook-up. Flue and stack, if required, are included in this assembly. The unit of measure at the assembly level is each.
D30 HVAC D302004 AUXILIARY EQUIPMENT (Auxiliary equipment is Optional.( Assemblies would include any other equipment associated with heat generating systems. The unit of measure at the assembly level is each. (Boiler Feedwater Tank, Chemical Feedwater, Feedwater Tank)
| D30 HVAC | COOLING GENERATING | |
| SYSTEMS | Cooling generating equipment of the absorption, centrifugal, reciprocating, and direct expansion types. |
D30 HVAC D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook-up. The unit of measure at the assembly level is each.
D30 HVAC D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, evaporators, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.
D30 HVAC D303090 OTHER COOLING GENERATING SYSTEMS General, Other, Unknown need to be avoided.
D30 HVAC DISTRIBUTION SYSTEMS This includes systems that distribute heated and cooled air, ventilating and exhaust air, hot and chilled water, steam, and glycol heating.
D30 HVAC D304001 AIR DISTRIBUTION, HEATING & COOLING Assemblies include air separators, dehumidifiers, humidifiers, VAV terminals, fire dampers, and smoke vents. The unit of measure at the assembly level is each.
D30 HVAC D304002 STEAM DISTRIBUTION SYSTEMS Assemblies include pipe and fittings, supports, wall and floor sleeves, and pipe insulation. The unit of measure at the assembly level is MBH. SMS does not currently have steam equipment adequately identified. Only inventory and assess equipment for which a PMTL is accomplished. Under “General” each section should provide enough information for future assessment and correction of data (date installed, size, location, condition, quantity).
D30 HVAC D304003 HOT WATER DISTRIBUTION SYSTEMS Assemblies pumps and heat exchangers Unit of measure at the assembly level is each.
D30 HVAC D304005 GLYCOL DISTRIBUTION SYSTEMS Inventory pumps and equipment under D304006.
| D30 HVAC | D304006 | CHILLED WATER DISTRIBUTION | |
| SYSTEMS | Assemblies include pumps, sensors and control valves Unit of measure at the assembly level is each. |
D30 HVAC D304007 EXHAUST SYSTEMS Assemblies include vents, dust collectors, and fans. Unit of measure at the assembly level is each.
D30 HVAC D304008 AIR HANDLING UNITS Assemblies include all fan sections, controls, sensors, and valves. Unit of measure at the assembly level is each.
D30 HVAC TERMINAL & PACKAGE UNITS This category includes self-contained heating and cooling units.
D30 HVAC D305001 UNIT VENTILATORS Assemblies include centrifugal, utility, or make-up air units. Unit of measure at assembly level is each.
D30 HVAC D305002 UNIT HEATERS Assemblies include hydronic or infrared units. Unit of measure at assembly level is each.
D30 HVAC D305003 FAN COIL UNITS Assemblies include cab/duct mount (2 or 4 pipe) and DX units. Unit of measure at assembly level is each.
D30 HVAC D305004 FIN TUBE RADIATION Assemblies include baseboard units. Unit of measure at assembly level is each.
D30 HVAC D305005 ELECTRIC HEATING Assemblies include electrical heating units. Unit of measure at assembly level is each.
D30 HVAC D305006 PACKAGE UNITS Assemblies can be cooling only or cooling with heating (air or liquid cooled, DX split or thru-wall, evaporative, heat pump, or rooftop) units. Unit of measure at assembly level is each.
D30 HVAC CONTROLS & INSTRUMENTATION Includes devices such as thermostats, timers, sensors, control valves, etc., necessary to operate the system as designed.
D30 HVAC D306001 HVAC CONTROLS General, Other, Unknown need to be avoided.
D30 HVAC D306002 ELECTRONIC CONTROLS Direct Digital Control (DDC) system. Includes devices such as supervisory, standalone, input/output controllers, network communications. The unit of measure at the network level is each system.
D30 HVAC D306003 PNEUMATIC CONTROLS Assemblies includes ball and butterfly valves, actuators, high pressure chokes, valve positioners, sensors, regulators, etc.
D30 HVAC D306004 INSTRUMENT AIR COMPRESSORS Assemblies include air compressors, dryers, and distribution tubing, (only used with pneumatic control systems). The unit of measure at the assembly level is each.
D40 FIRE PROTECTION FIRE ALARM AND DETECTION SYSTEMS This subsystem includes fire alarm and mass notification control panels and distribution, fire detection devices, notification appliances, electromechanical releases, and all electrical connections and other associated items.
D40 FIRE PROTECTION D401001 FIRE ALARM DISTRIBUTION Assemblies include general (wiring, conduit, conduit support or fastening systems, switches and connections); conventional fire alarm control panel (single, multi-zone); addressable fire alarm systems, mass notification systems, and combination systems.
D40 FIRE PROTECTION D401002 FIRE ALARM DEVICES Assemblies include notification appliances and detection devices: alarm bell, annunciator, strobe, strobe/annunciator combo, battery backup, fixed temperature heat detector, smoke detector, rate of rise heat detector, manual pull station, rate compensate heat detector, combination heat/smoke detectors, duct detectors, and explosion proof devices such as, detectors, pull stations, and notification appliances.
D40 FIRE PROTECTION FIRE SUPPRESSION WATER SUPPLY AND EQUIPMENT This subsystem includes items located upstream of the suppression systems such as, backflow preventers, piping, fire pumps etc. supplying a single facility. Equipment supporting multiple facilities is covered as a water utility.
D40 FIRE PROTECTION D402001 FIRE PROTECTION WATER PIPING AND EQUIPMENT Assemblies include air compressor, air dryer, reduced pressure backflow preventers, and double check valve backflow preventers.
D40 FIRE PROTECTION D402002 FIRE PUMP Assemblies include fire pumps (including controller), jockey pump including (controller and disconnects); fire pump test header, flow meters, and recirculation system; and hydraulic transience controls (surge arrestors).
D40 FIRE PROTECTION STANDPIPE SYSTEMS This subsystem includes the standpipe risers, racks, cabinets, hoses, hose connections, and all other piping, fittings, and supports associated.
D40 FIRE PROTECTION D403001 STANDPIPE EQUIPMENT & PIPING Assemblies include wet or dry, class I, II, or III, hose connections for ground floors, and each additional floor.
D40 FIRE PROTECTION SPRINKLERS This subsystem includes the water supply equipment and related piping, control valves, alarm valves, and connections, from the base of the riser to the sprinkler head.
D40 FIRE PROTECTION D404001 SPRINKLERS AND RELEASING DEVICES (SYSTEMS) Assemblies include wet-pipe, dry pipe, pre-action, deluge, and multi- cycel systems spanning mulitple hazard categories.
D40 FIRE PROTECTION D404002 SPRINKLER WATER SUPPLY EQUIPMENT AND PIPING Assemblies include alarm valves, flow control valves, pipe and fittings from equipment to sprinkler heads, including all supports and wall or floor sleeves. All equipment including tanks, pumps, and other associated equipment, fittings and specialties required for hook-up are in this assembly. The unit of measure at the assembly level is each sprinkler head.
| D40 FIRE PROTECTION | OTHER FIRE PROTECTION | |
| SYSTEMS | This subsystem includes special fire detection and extinguishing systems. |
D40 FIRE PROTECTION D409001 CARBON DIOXIDE SYSTEMS Assemblies include carbon dioxide systems.
D40 FIRE PROTECTION D409002 FOAM GENERATING EQUIPMENT Assemblies include all high expansion foam, AFFF, and foam-water deluge systems.
D40 FIRE PROTECTION D409003 CLEAN AGENT SYSTEMS Assemblies include all halon, clean agent, and inert gas systems.
D40 FIRE PROTECTION D409090 OTHER FIRE PROTECTION SYSTEMS Assemblies include ultasensative smoke detection systems, UV/IR3 detectors.
D50 ELECTICAL ELECTRICAL SERVICE & DISTRIBUTION This system provides for all electroical devices that are required to deliver the main source of power to the facility and to distribute this power to distribution subpanelboards.
D50 ELECTICAL D501001 MAIN TRANSFORMERS Transfpormers used for pimary electrical service and located near or within the facility. Assemblies include transformers, raised pad, trenching, and backfill. Inventory distribution transformers in SMS UTILITY
D50 ELECTICAL D501002 SERVICE ENTRANCE EQUIPMENT This includes the protection equipment and metering devices for main distribution. Assemblies include underground conduits and service entrance conductors from the secondary taps of the distribution transformer to the Main Distribution Panel, protected service disconnects (circut breakers or fuses), and meters. Main distribution panels should be inventoried under D501004 Panelboards.
D50 ELECTICAL D501003 INTERIOR DISTRIBUTION TRANSFORMERS Transformers fed downstream of the Main Distribution Panel. Assemblies include transformers, conduit, conduit support, and wire from the Main Distribution Panel to the Transformer.
D50 ELECTICAL D501004 PANELBOARDS Branch circuit distribution panelboards. Assemblies include panelboards, breakers, and conduit and wire provideing power to the panelboards. Main Distribution Panelboards and distribution subpanels are included in this equipment category. Also includes Automatic Transfer Systems (ATS) that normally selects the primary or normal source of power from an emergency source when the primary or normal source of power is interrupted.
D50 ELECTICAL D501005 ENCLOSED BREAKERS Over-current protection device enclosed in its own housing for protecting a single circuit. Asseblies include enclosed circuit breaker, conduit and wiring providing power to the enclosed circuit breaker.
D50 ELECTICAL D501006 MOTOR CONTROL CENTERS This is a cabinet in which motor starters and operational devices are contained. Assemblies include the motor control center cabinet, motor starters, contacts, switches, conduit and wire providing power to the motor control center and all associated items.
D50 ELECTICAL LIGHTING AND BROANCH WIRING Lighting systems include light fixtures and devices, i.e., switches, recepticles, and equipment connections.
D50 ELECTICAL D502001 BRANCH WIRING This assembly includes conduit and wire from a branch circuit ditributio panelboard to recepticles, lighting switches, and equipment connections. Recepticles are also included.
D50 ELECTICAL D502002 LIGHTING EQUIPMENT This assembly includes conduit and wire from switching devices to fixtures, fixture mountings, lamps (type and wattage), and switching devices. Includes interior and exterior (attached to facility). Exit lights to identify code required ingress/egress paths are also included.
D50 ELECTICAL OTHER ELECTRICAL Systems not included in System D5030
D50 ELECTICAL D509002 EMERGENCY LIGHTING AND POWER Assemblies include fixtures, motors used for power generation, connection and teating, conduit, wire, battery chargers, batteries, and solar panels.
D50 ELECTICAL Emergency Lighting Lighting providing illumination for a pathway to emergency exit in a facility in the event of failed electrical power
D50 ELECTICAL Emergency Power (Generator) An emergency generator providing electrical power to a facility or system in the event the primary or normal source of power is interrupted.
F-TE-2f
TOC
F-TE-2f Reserve Training
AFSC Annual Hours
3E0X1 - Electrical/Power Production 116
3E1X1 - HVAC 116
3E2X1 - Pavements/Equipment 116
3E3X1 - Structures 116
3E4X1 - WFMS (Plumbing/Fuels) 116
3E6X1 - Ops Mgt 116
F-TE-2g
TOC
F-TE-2g. Facilities requiring Pest Management Inspections
Facility Isp Frequency Square Footage
470 Monthly 12,798
440 Monthly 1,654
474 Monthly 27,979
F-TE-2h
TOC
F-TE-2h. Sand Barrel/Ice Melt Buckets/PVC Snow Marker Stakes and Hydrant Flags:
Location Est Qty
Sand Barrel/Ice Melt Buckets/Snow Shovels Basewide 60
Snow Marker Stakes 800
F-TE-2i
F-TE-2i. Facilities to Be Maintained By KTR. The KTR shall inspect and clean mechanical/utility rooms monthly. TOC
Facility Nomenclature QTY Bld Story Roof Type Gutter Inspections Qty in SF Utility Mechanical Room Building Gutters and Downspouts to be maintained:
15 Billboard 1 ea Location Quantity
98 Storage 864 1 Asphalt Shingle Basewide Gutters 27,443 LF
99 Rec facility 1ea Asphalt Shingle Basewide Downspout/Leaders 14,930 LF
100 Old Fire Station 16,007 1 Tar
102 Switch Station 1 ea
151 Comm 3,084 1 Fiberglass Shingle
153 Antenna Support 1 ea
201 Sewage Pump Sta 250 1 Metal
207 Storage 2,064 1 Metal
209 Supply 94,007 1 Metal
20907 Warehouse Sup & Equip 120 1 Precast Concrete
20908 Warehouse Sup & Equip 120 1 Precast Concrete
20909 Warehouse Sup & Equip 120 1 Precast Concrete
20910 Warehouse Sup & Equip 120 1 Precast Concrete
20911 Warehouse Sup & Equip 120 1 Precast Concrete
20912 Warehouse Sup & Equip 120 1 Precast Concrete
20913 Warehouse Sup & Equip 120 1 Precast Concrete
20914 Warehouse Sup & Equip 120 1 Precast Concrete
20915 Warehouse Sup & Equip 120 1 Precast Concrete
20916 Warehouse Sup & Equip 120 1 Precast Concrete
20917 Warehouse Sup & Equip 120 1 Precast Concrete
20918 Warehouse Sup & Equip 120 1 Precast Concrete
20919 Warehouse Sup & Equip 120 1 Precast Concrete
20920 Warehouse Sup & Equip 144 1 Precast Concrete
20921 Warehouse Sup & Equip 144 1 Precast Concrete
20922 Warehouse Sup & Equip 144 1 Precast Concrete
20923 Warehouse Sup & Equip 144 Precast Concrete
20924 Warehouse Sup & Equip Precast Concrete
211 Load Platform 1 ea
213 Supply Shed 6,336 1 Metal
214 Supply Shed 6,336 1 Metal
233 Haz Storage Fac 5,775 1 Metal
23901 Retaining Wall Coal yard 763 LF
241 Scales 1 ea 891 1
380 Mogas storage 10,000 ga 1
381 Solvent Storage 25,000 ga 1
382 Solvent Storage 25,000 ga 1
383 Hydrant Fueling Building Metal
384 Veh Fill Station - Overhead Protection Metal
385 Veh Fill Station - Overhead Protection Metal
391 Light, Beacon 1 EA 1
393 Truck Inspection 1,928 1 Metal
394 Visitor’s Center 1,600 1 Metal
395 Fuels Pmp Sta 274 Metal Gable
396 Petrol Ops Bldg 2,438 1 Asphalt Shingle
397 Fuels Unload 10L 1
399 Trk Fill Stand 10L 1
400 Fuel Storage Tank 630,000 ga
402 Fuel Storage Tank 630,000 ga
403 Fuel Storage Tank 630,000 ga
404 Hydr FL Bldg 1,342 1
405 POL Storage Shed 1,008 Metal
412 Veh Parking 25,101 SY 3
413 Trk Fill Stand 20L 1
414 Trk Fill Stand 20L 1
416 Fuels Unload 40L
419 Veh Fill Station 30L Metal
420 Veh Maint 29,123 Metal
421 Refuel Veh 2,113 1 Metal
422 Antenna Support 1 ea 1
423 Rec Facility 1 ea 1
426 Aircraft Shop 19,444 1 Metal
427 Res Forces Tng 29,041 2 Metal/Built-up
428 EOD Vehicle Ops Parking Garage 3,100 2 Metal
430 SP Ops 8,518 1 Metal
431 Res Forces Tng 8,460 Metal
433 Rec Pavilion (Reserve Forces Gen Training) Asphalt Shingle
434 Nose Dock 36,267 2 Metal
435 Nose Dock 28,679 2 Metal
436 Nose Dock 28,679 Metal
437 Nose Dock 31,142 2 Metal
438 Nose Dock 29,471 2 Metal
439 Nose Dock 31,738 2 Metal
440 Community Activity Center 1,654 1 Metal
441 Community Center Pavilion 1,200 1 Metal
443 Main Gate 1,680 1 Metal
444 Overwatch Facility 77 1 Metal
44301 Billboard 1 EA
446 Vehicle Barrier 1 EA
447 Access Control Facility (Annex Guard Shack) 36 SF 1 Pre-Fab Metal
448 Contract/TMO 17079 1 Metal
44801 Retaining Wall 182 LF
450 MWR Facility 5,120 1 Metal
451 Veh Parking Comp 6,967 SY Metal
452 Sanitary Sewer Pump Station 30
453 Aircraft Shop 9,733 1 Metal
45301 Retaining Wall 135 LF
454 Carwash 1,477 1 Metal
455 Aircraft Shop 166 Asphalt Shingle
460 Rec Facility 1 ea 1
467 Recreation Pavilion 1500 Metal
468 Recreation Pavilion 1500 1 Metal
469 Billboard 1 ea 1
470 Dining Hall 12,798 Metal
474 Fire Station 27,979 1 Metal
47410 Vehicle Parking Non Org 1,784 SY
47420 Fire Dept Sidewalks 450 SY
475 Fire Dept Storage 3,496 Metal
476 Deluge Pump Station 1,222 Metal
477 Fire Reserve Station Metal
563 Gym 11,580 1 Metal/Tar
572 Toilet/Shower Building 1,369 1 Metal
573 Athletic Field/Softball 75,966
574 Tennis Court 7,200
575 Basketball Court 7,980
576 Volleyball Court 3,911
578 Horseshoe Court 500
591 Jet Eng Shop 10,501 1 Metal
592 Maint Shop 68,085 1 Metal
59211 Elec Aircraft Outlets 6 ea
593 A/SE Shop 7,195 1
59301 Veh Fuel Sta 380 1
59302 Indust Waste/Treatment 1KG
595 Res Forces Tng 13,616 1
59501 Sewage Pump Sta 28
596 Res Forces Tng 36,985 2 Metal
59601 Ant support structure 2 ea
59602 Sewage Pump Sta 12
597 Res Forces Tng 14,858 2 Metal/Tar
59701 Sewage Pump Sta 20
599 Base Flag Pole 1 ea
600 Base Operations 31,485 1 Metal
60001 Sewage Pump Sta 36
60002 Retaining Wall 45 Sy
601 Rec Facility 1 ea Asphalt Shingle
602 Util Vault 684
604 Shed Sup & Equip BSE
609 Aerial Port Training Facility 1
611 Veh Fill Station - Overhead Protection
624 DASR/Generator 618 1 Precast Concrete
627 Fire Training Plane
628 Fire Simulator 1 ea 4 Metal
629 Firing Range 15 FP/3,596 Metal
633 CE Compressed Gas Building 1 ea 1 Metal
634 Open Grenade Launch 1 ea Metal
636 Storm Detention Pond 1 ea
637 Rec Facility 1 ea Metal
638 Sewage Pump Sta 75 Metal
641 BCE Facility 50,984 1 Metal
64110 Vehicle Parking Non Org 45,442 SY
64120 BCE Sidewalks 600 SY
64130 Open Storage BCE 132110 Sy
64140 Misc Storage Tank 1 ea
642 BCE Storage 2,000 1 Metal
643 Pest Control Shop 2,160 1 Metal
644 Pavilion 1 ea Asphalt Shingle
645 Readiness Storage 3,360 1 Metal
646 Pedestrian Bridge 1 ea
647 Marine Retention Pond 3,200LF
648 Marine Complex 23,544 SF 1 Metal
64810 Vehicle Parking Non Org 3,683 SY
64820 Marines Sidewalks 520 SY
64840 Vehicle Parking Org 3667 SY
649 Marine Vehicle Wash Facility 1,683 SF Metal
661 Rec Facility 1 EA Asphalt Shingle
663 Sqdrn Ops 25,965 1 Steel (P.S.R.)
665 Antenna Support 2 EA
667 Res Forces Tng 9,182 1 Metal
668 Sqdrn Ops/Simulator 13,147 2 Metal
669 Medical Fac 18,660 1 Metal
670 Res Forces Tng 8,398 1 Metal
671 Cmd Post/Offices 14,907 1 Metal
674 Road Bridge 60 LF
676 Antenna Support 4 ea
679 Fuel Spill Collector 36 kg
683 Admin Offices 1709 1 Metal
685 Weigh Scale 1 ea
687 Recycle Shop 4,000 1 Metal
688 Generator Shop 4,000 1 Metal
689 Load Platform 270
691 BCE Storage Shop 1,200 1 Metal
692 Traffic Chk House 132 1 Asphalt Shingle
694 Ammo Bunker 1,500 1 Concrete-Earth
695 Ammo Storage 760 1 Metal
696 Ammo Storage 2,400 1 Metal
702 Airfield Instruments 197
703 Deicing Recovery 956 BL
704 ILS/Generator 1 ea
705 ILS/Generator 1 ea
708 ASR/Generator 1,520
714 Vortac 1 ea
716 Comm/Receiver 1
731 ILS/Generator 1 ea
732 Airfield Instruments 2 ea
739 Fuels Hydraulic System 1,750 gm
740 Pipeline 22,550 LF
760 RAPCON 9,500 1 Metal
761 Rec Pavilion (Rapcon Center) Asphalt Shingle
762 Control Tower 6,992 7 EPDM
767 Airfield Lighting Vault 1 ea 1 Metal
770 Windsock 1 ea
771 Windsock 1 ea
772 Airfield Instruments 1 ea
791 Septic Tank 1 ea 36KG
805 Water well 26 kg
809 Pump House 1
810 Septic Tank 1 ea 1 KG
887 Spill Collector 3kg
895 Spill Collector 25kg
899 Walkway Bridge 157 LF
900 Steam mains(VACANT) 82856 LF
901,905, 957 Roads Includes 905, 957 130,619LF
903 Road Bridge 20 LF
904 Vehicle Parking Non Org 113,873 SY
913 Vehicle Parking Non Org 292 SY
931 Vehicle Parking Non Org 2,323 SY
906 Sidewalk 22,374SY
907 Retaining wall 1,077 SY
908 Driveway Includes 911, 929 68,221 SY
909 Load Platform 23,309
912 Curbs and Gutters 89,612LF
914 Open storage 6,076 SY
915 Open storage 16,009 SY
916 Vehicle Parking Org 5,514 SY
932 Vehicle Parking Org 374SY
917 Open Storage 6,458 SY
919 Gas Mains 28,735 LF
921 Water Dist Mains 43,318LF
922 Storm Drain Disp 108,274 LF
923 Water Supply Main 28,813 LF
925 Fire Protection Water Mains 9,001 LF
926 Sanitary Sewer Main 47,279 LF
927 Fire Hydrants 91EA
935 Equip Pads 1,545 SY
937 Telephone pole Fac 630 LF
938 Exterior lights 313 EA
940 OH Power lines, Primary 2,612 LF
941 UG power lines, Primary 6,522 LF
943 Telephone ducts 8 mi
946 OH Power lines, Second 758 LF
947 UG Power lines, Second 12,913 LF
950 Security fence 14,762LF
951 Interior fence 1139 LF
952 Boundary Fence 64,101 LF
954 Aircraft Storage 3,252 SY
955 Runway 277,777 Sy
956 Navy Runway 38,000 Sy
958 Power Check Pad 7,301 SY
959, 960 Power Check Pad Includes 960 9,331 SY
961 Jet Engine Shop 750 Metal
963 Oil Water Separator 15 kg
964 Oil Water Separator 30 kg
965 Oil Water Separator 25 kg
966 Oil Water Separator 40 kg
967 Traffic Lights 3 ea
971 Approach lights 2,400 LF
973 Open Storage Supply 100 SY
980 Support Structure 88 EA
984 Wash Rack 6100
986 Approach lights 12,000 LF
987 Taxiway Lights 28,977 LF
988 Runway Lights 34,251 LF
989 Airfield Lights 2 ea
991 Apron 301,441 SY
996 Pad Power Check 563 Sy
997 Paved Shoulders 351,738 SY
998 Taxiway 380,807 SY
999 Overruns 44,444 Sy
F-TE-2j
TOC
F-TE-2j. Grounds Maintenance - Wetlands - Herbicide Application Summary
Item Amount Unit Note
Improved Grounds 79.39 Acres
Edging 130,351 Linear Feet
Trim 25,660 Linear Feet Includes 2,430 LF of fencing (2,280 LF for POL)
Police improved grounds 86.78 Acres Additionally this includes 580,833 square yards of paved areas within the improved grounds.
Shrubs 358 Each
Hedge 265 Linear Feet
Mulch 22,000 Square Feet See Grass Cutting Map
Mulch around trees 5,680 Square Feet Set Tree Mulching Map
Fence 67,733 Linear Feet
Semi-improved Grounds 932.23 Acres 295 acres of this is BASH
Vegetation Control security fences 67,733 Linear Feet 26,660 linear feet to be treated with herbicide
Vegetative beds 41,224 Square Feet
Flower beds 700 Square Feet
Stream banks & Drainage ditches 28,716 Linear Feet
Wetlands on NFARS: F-TE-7 Base Wetland Delineation Map
Wetland ID Acres
Wetland A 4.87
Wetland B 5.28
Wetland C 2.71
Wetland D 2.02
Wetland E 1.19
Wetland F 2.38
Wetland G 0.7
Wetland H 0.67
Wetland I 0.86
Wetland J1 0.7
Wetland J2 0.1
Wetland K 1.43
Wetland L 0.28
Wetland LA 0.09
Wetland LA2 0.04
Wetland LA3 0.01
Wetland M 0.12
Wetland N 1.32
Regulated Ditches 24,000 LF
Cayuga Creek 1,000 LF
Herbicide Application Summary
Area of Application Herbicide Combination* Application Times Acres to be Treated Maximum Estimated Application Volume per Treatment (pints) Purpose
Fenceline Pre-emergent: AM-40, Barricade Growing season, IAW manufacturer’s recommendations. Maximum application of twice per year. 0.61 AM-40: 0.61 Retard weed growth and help to eradicate resilient weeds.
Post-emergent: Roundup Pro™ or Kleenup Pro™, Triamine® Barricade: 0.61
Roundup Pro™: 4.90
Kleenup Pro™: 1.22
Triamine®: 2.44
Railroad Tracks, Taxiways, and Runway Overruns Pre-emergent: AM-40 Growing season, IAW manufacturer’s recommendations. Maximum application of twice per year. 1.88 AM-40: 1.88 Eradicate vegetation and help to eradicate resilient weeds.
Post-emergent: Roundup Pro™ or Kleenup Pro™, Triamine® Roundup Pro™: 15.04
Kleenup Pro™: 3.76
Triamine®: 7.52
Improved Areas Pre-emergent: Growing season, IAW manufacturer’s recommendations. Maximum application of twice per year. 87.5 Barricade: 116.10 Broadleaf weed control.
Barricade Triamine®: 464.40
Post-emergent:
Triamine®
Tree Beds and Landscape Beds Pre-emergent: Growing season, IAW manufacturer’s recommendations. Maximum application of four times per year. 1.07 Barricade: 1.07 To control weed growth in tree beds and landscape beds.
Barricade Roundup Pro™: 8.56
Post-emergent: Roundup Pro™, Triamine® Triamine®: 4.28
F-TE-2k
TOC
F-TE-2k Pavements Clearance Maintenance Consumable Estimates (Sweeper & Snow Removal)
F5.3.1.2 Pavement Sweeping. See Airfield and Street Sweeping Plans in F-TE-7
Flightline Sweeping Equipment
Estimate only and is dependent on frequency of use and operator proficiency.
Equipment Type Frequency Qty
Curtain Replacements Annual 4 Sets
Gutter Broom Replacements Annual 4 Sets
Snow Plow Blades, Brooms: Frequency is Annual
Equipment Type Size Qty
Blades 72”x6” 3 Ea.
Blades 100”x8” 1 Ea. every other year
Blades 96”x8”x5/8” 1 Set. Set equals 2
Under Body Grader Blades 72”x6” 10-15 Sets. Set equals 2
Shoes 32 Ea.
Broom Core Replacements 18’ Wide 2-4 Sets
F-TE-2l
TOC
F-TE-2l High Mast Lighting
Area Pole Number Heads Height Wattage
F-TE-2-m
F5.3.1.1.3 Locksmith Program
Quantity keys cut per year 200
Sheet of
SHEET NUMBER
S U
B M
I T
E
D
Y
R
A W
N
G
V
PROJECT NO.
ISSUE DATE:
VER.
C H
F
L
P
O J
Z
K
1OCT 2022
N/A
F-TE-7
BASE OPERATING SUPPORT CONTRACT
CONTRACT NO:
AWARD DATE:
u s c e a b o n t r w i g d
AutoCAD SHX Text
BOOM PLACE
G-731
TAXIWAY 'E'
US. HWY. 31
NE - SW (INSTRUMENT) RUNWAY 200' X 12,500'
PARALLEL TAXIWAY 'F'
TAXIWAY 'D'
OFF BASE
DINING FACILITY
77901
TOWER
WATER
TAXIWAY 'B'
NE - SW (INSTRUMENT) RUNWAY (200' X 12,500')
TAXIWAY 'C'
TAXIWAY 'G'
EAST LOOP ROAD
G-702
20001
G-28
(11)
G-14
20901-20924
10001
TAXIWAY 'A'
MAINTENANCE
VEHICLE
HOOSIER BLVD
59601
59602
60001
59302
59301
59701
67102
G-671
DEAN BALDWIN
59501
WEST GATE
WARTHOG STREET
GRISSOM AVENUE
G-410
FORTRESS ST.
33701
DOC EVENS AVE.
THUNDERBOLT AVE.
STORAGE AREA
RV
G-404
HARRY FOREMAN DR.
TANKER
STREET
CHOCKS LANE
SKYTRAIN
BOOM
PLACE
BOXCAR
BAKALAR LANE
ATTERBURY WAY
SEXTANT LANE
LEATHERNECK
DRIVE
DRAGONFLY LANE
MUNITIONS DRIVE
DOC EVENS AVENUE
DISCOUNT TIRE WAREHOUSE
MARATHON GAS STATION
CAR DEALERSHIP
GRISSOM AEROPLEX AIR PARK AND MUSEUM
DRIVING RANGE
LEANING TREE GOLF COURSE
TAXIWAY 'H'
PAINTING
(200)
MIAMI COUNTY AVIATION
C-STORE
VILLAGE
PANTRY
GAS MAIN
WAREHOUSE
VERSION
APPROVED BY:
DESCRIPTION
DATE
FH
SS
ST
CB
MW
G-731
TAXIWAY 'E'
MATCH LINE
MATCH LINE
ROADS, PARKING & R.R.S
STREETS, ROADS, RAILROADS
AND VEHICLE PARKING AREAS
EDGE OF RUNWAY, TAXIWAYS, PARKING RAMP
OVERRUN
DRAINAGE CHANNEL OR DITCH
NATURAL FEATURES
AIRFIELD PAVEMENT
AIR FORCE PROPERTY LINE
%%uLEGEND
WETLANDS
GRAPHIC SCALE IN FEET
776 ILS LOCALIZER
FAC # DESCRIPTION
727 CONTROL TOWER
715 TRANSMITTER/RECEIVER
708 ASR
151 TELEPHONE EXCHANGE BUILDING
102 ELECTRICAL SWITCHING STATION
18 RAPCON COMMUNICATION BUILDING
THE FOLLOWING ARE USAFR FACILITIES OUTSIDE AIR FORCE OWNED PROPERTY
M. S. L.
MAG VARIATION 4%%D 27' WEST
DATE OF DATA MAY 2010
ANNUAL CHANGE 0.1%%D WEST
AIRFIELD ELEV. 811' ABOVE
ELECTRICAL ROOM RM 224
CANOPY
RM 100
STRUCTURES SUPPORT RM 115
RESOURCES OPERATIONS RM 114
STORAGE RM 113
READINESS OPERATIONS RM 111
READINESS CHIEF RM 112
OPS PROGRAMMING CHIEF RM 109
OPS OFFICER RM 110
PROGRAMMING RM 108
ORDERLY ROOM RM 106A
1ST SGT ART RM 106C
TMG ART RM 1011
SENIOR ART RM 107
ASSOCIATE ART RM 106B
ADMINISTRATION RM 102
COMMANDER'S OFFICE RM 104
BASE CIVIL ENGINEER RM 103
RM 136
RM 135
COPY ROOM RM 105
TRAINING ROOM RM 119
RM 101
MEETING/ CONFERENCE RM 118
OPERATIONS ADMINISTRATION RM 120
OPERATIONS OFFICE RM 121
WOMEN'S ROOM
MEN'S ROOM
ENVIRONMENTAL OPERATIONS RM 124
ENVIRONMENTAL CHIEF RM 125
OFFICE RM 126
CHIEF OF DESIGN RM 128
ENGINEERING CHIEF RM 129
OPERATIONS OFFICE RM 127
PRINT ROOM RM 130
STORAGE RM 117
CONTRACT OFFICE RM 132
CONTRACT MANAGEMENT RM 131
CONFERENCE/ CLASSROOM RM 116
STRUCTURES FOREMAN RM 209
STORAGE RM 219
RM 201
RM 137
RM 138
BREAK ROOM RM 139
JANITOR'S CLOSET RM 228
MEN'S LOCKER ROOM
STRUCTURES OFFICE RM 210
SIGN SUPERVISOR RM 211
ELECTRICAL TESTING RM 212
STRUCTURES SHOP RM 213
ELECTRICIAN RM 215
CARPENTRY RM 214
ELECTRICAL DISTRIBUTION RM 216
SHEET METAL RM 217
LOCKSMITH RM 216
PAVEMENTS AND GROUNDS RM 300
HORIZONTAL FOREMAN RM 220
HORIZONTAL RM 221
MATERIAL CONTROL OFFICE RM 226
SUPPLY RM 225
MOBILITY OFFICE RM 222
MOBILITY RM 223
MATERIAL CONTROL RM 227
OVERHEAD DOOR (TYPICAL)
RM 134
RM 202
RM 200
RM 203
WOMEN'S LOCKER ROOM
WOMEN'S ROOM
MEN'S ROOM
RM 301
RM 232
RM 107
RM 101
RM 106
RM 109
RM 108
RM 110
RM 104
RM 105
RM 102
RM 103
OVERHEAD DOOR
%%UBUILDING 641
SCALE: NONE
%%UBUILDING 642
%%UBUILDING 643
%%UBUILDING 691
CONTRACTOR ADMINISTRATION AREAS
JOINT SHOP USE AREAS
CONTRACTOR STORAGE AREA
WINDCONE
VG 14'
VG 20'
ROADS, PARKING & R.R.S
STREETS, ROADS, RAILROADS
AND VEHICLE PARKING AREAS
EDGE OF RUNWAY, TAXIWAYS, PARKING RAMP
OVERRUN
AIRFIELD PAVEMENT
AIR FORCE PROPERTY LINE
SWITCH
TRANSFORMER, PAD MOUNTED
UTILITY
HANDHOLE
MANHOLE
GENERATOR
PRIMARY OVERHEAD
PRIMARY UNDERGROUND
SECONDARY OVERHEAD
SECONDARY UNDERGROUND
X600
X629A
X629
X628
X696
X639
X687
X683
X648
X692
X593
X591
X596
X597
X592B
X592A
X595
X638A
X638B
X668A
X668B
X669
X667
X663
X641
X473
X472
X470
X440
X421
X420
X394
X404
X201
X396
X563
X427B
X427A
X476
X430
X474
X426A
X426B
X453
X100
X434
X431
X435
X436
X436A
X439B
X233
X448
X439A
X438
X670
X437
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
X13
X736
X767
X523
X735
X714
X715
X708
X727
X704
X702
X760
X393
X645
X475
XFR-00563-01
XFR-00443-01
XFR-00426-01
XFR-00101-01
XFR-00431-01
SCI4-1
NEED ID
SCI-7
SC9-2
SCI2-1
MH211E
MH229E
AutoCAD SHX Tex
This is the start of the file's text. The full file is on GovTribe.