Attachment 10 - FMECA.docx
DOCX document 14 KB Posted
- Attached to
- DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
- Solicitation number
- W31P4Q-20-R-0015
About this file
This document contains the Failure Modes and Effects Criticality Analysis (FMECA) for the Integrated Battle Command System (IBCS) hardware components. The analyses evaluate numerous system components including relay and connected line replaceable units, shelter equipment, and workstation accessories. Potential failure modes are identified and assessed for each item. The FMECA reports will inform engineering changes that may be required under the anticipated IBCS Hardware Low Rate Initial Production/Full Rate Production contract. The draft solicitation seeks proposals for the production of IBCS end items in accordance with supplied technical data packages and specifications. Engineering support will also be needed to address obsolescence issues, implement new capabilities, and ensure export compliance. The Department of the Army is the contracting agency.
View the file
Other files for this federal contract opportunity
Show all 50
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 10 - FMECA Attachment 10 contains the following documents:
Attachment 10a – Appendix A IFCN Relay and Connected LRUs – for FMECA Attachment 10a.1 – R001 HRFU-FMECA Attachment 10a.2 – R002 BPU-FMECA Attachment 10a.3 – R003 KG-250X-FMECA Attachment 10a.4 – R004 IGRM-FMECA Attachment 10a.5 – R005 SCIM-FMECA Attachment 10a.6 – R006 TIMING UNIT-FMECA Attachment 10a.7 – R007 Relay Network Switch-Parvus Switch-FMECA Attachment 10a.8 – R008 Media Converter Chassis-FMECA Attachment 10a.9 – R015 PDU Assembly-FMECA Attachment 10a.10 – R016 thru R025 Media Converter Module-FMECA Attachment 10a.11 – R029 PFPU SSHD-1—FMECA Attachment 10a.12 – R030 PFPU SSHD-1—FMECA Attachment 10a.13 – R031 Black Router--FMECA Attachment 10a.14 – R032 Media Converter Module 11-FMECA Attachment 10a.15 – R033 Media Converter Module 12-FMECA Attachment 10a.16 – R034 Media Converter Power Supply-FMECA
Attachment 10b – Appendix B1aEOC – Shelter less ICE-for FMECA
| Attachment 10b.1 – E001 28VDC Pwr Supply Shelter Power-FMECA |
| Attachment 10b.2 – E002 Power Inverter Shelter Power-FMECA |
| Attachment 10b.3 – E005 Blower Assembly-FMECA |
| Attachment 10b.4 – E013 ADSI Shelter – Misc Equip-FMECA |
| Attachment 10b.5 – E029 KVM Switch 1 Shelter Stack-FMECA |
| Attachment 10b.6 – E030 KVM Console-FMECA |
| Attachment 10b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA |
| Attachment 10b.8 – E032 R112 Shelter – Server Stack – 02-FMECA |
Attachment 10b.9 – E033 R112 Shelter – Server Stack – 03-FMECA Attachment 10b.10 – E034 R112 Shelter – Server Stack – 04-FMECA
Attachment 10c – Appendix B1bEOC – Shelter less ICE-for FMECA Attachment 10c.1 – E043 Firewall Red-FMECA Attachment 10c.2 – E044 Firewall Black-FMECA Attachment 10c.3 – E048 HRFU-FMECA Attachment 10c.4 – E049 BPU-FMECA Attachment 10c.5 – E050 KG-250X-FMECA Attachment 10c.6 – E051 IGRM-FMECA Attachment 10c.7 – E052 SCIM-FMECA Attachment 10c.8 – E053 Shelter Time Server-FMECA Attachment 10c.9 – E059 Shelter Switch – 01-FMECA Attachment 10c.10 – E060 Shelter Switch – 02-FMECA Attachment 10c.11 – E061 Isolation Router Red-FMECA Attachment 10c.12 – E062 Shelter Router-Red-FMECA Attachment 10c.13 – E063 Isolation Router Black-FMECA Attachment 10c.14 – E064 Shelter Router Black – FMECA Attachment 10c.15 – E068 Media Converter 02 – FMECA Attachment 10c.16 – E069 Media Converter 03 - FMECA
Attachment 10d– Appendix B1cEOC – Shelter less ICE-for FMECA Attachment 10d.1 – E123 TMSS – ECU-FMECA Attachment 10d.2 – E144 RWS Bkup Batteries-FMECA Attachment 10d.3 – E150 S-280 PEV-FMECA Attachment 10d.4 – E151 – Media Converter 04-FMECA Attachment 10d.5 – E152 – Media Converter 05-FMECA Attachment 10d.6 – E153 RS112 Server -05 Shelter with PT-FMECA Attachment 10d.7 – E153 RS112 Server -06 Shelter with PT-FMECA Attachment 10d.8 – E153 RS112 Server -07 Shelter with PT-FMECA Attachment 10d.9 – E156 UPS-FMECA Attachment 10d.10 – E157 KVM Switch 2 Shelter-FMECA
Attachment 10e– Appendix B2 EOC –ICE-for FMECA Attachment 10e.1 – E067 – EtherNet Switch-FMECA Attachment 10e.2 – E082 thru E091 Wkstn Laptop-FMECA Attachment 10e.3 – E092 thru E101 Wkstn Display-FMECA Attachment 10e.4 – E102d thru E111 Vid Extender-FMECA Attachment 10e.5 – E122 – EMI Tent PDU-FMECA Attachment 10e.6 – E143 – ICE UPS-FMECA Attachment 10e.7 – E145 – Table 1 Assembly-FMECA Attachment 10e.8 – E146 – Table 2 Assembly-FMECA Attachment 10e.9 – E147 – Table 3 Assembly-FMECA Attachment 10e.10 – E148 – Table 4 Assembly-FMECA Attachment 10e.11 – E149 – Table 5 Assembly-FMECA
Attachment 10f – IBCS – 243-003 HW FMECA Results Attachment 10g - IBCS – 243-003 HW FMECA Results Attachment 10h – SWFMEA RESULTS
File details come from the government source that posted it. Updated .