This document contains a federal contract opportunity solicitation for the overhaul of rotor turbine aircraft. The contractor shall overhaul a minimum of 5 and maximum of 414 rotor turbine aircraft per year over 5 years, including 69 for foreign military sales. The overhaul includes all necessary labor, facilities, parts, materials, equipment and data to refurbish the input nsn 2840-01-515-3538 to the output nsn. The proposed contract is a firm fixed price IDIQ for the maintenance and overhaul. Technical data includes a DMWR and applicable MEOs. The rotor turbine aircraft is a critical safety item, so overhaul can only be performed by approved sources in accordance with DFARS 209.270-3. Currently the only approved source is GE Engine Services. Firms are encouraged to identify themselves and seek approval to compete on future solicitations. Proposals are due by the estimated closing date and must be submitted electronically to the provided email addresses. Award is contingent on sufficient funding.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAINTENANCE ENGINEERING ORDER
(AMCOM Reg. 750-2)
MEO NO.
DATE PAGE 1 of
TITLE Tolerances Unless otherwise noted, dimensions are in inches and tolerances are:
Fractional ………………… ± 1/32 Decimal ………………... ± 0.010 Angular ………………… ± ½°
APPLICABILITY CSI Critical Characteristic Affected?
Impact Statement Attached?
REFERENCES FOR RDECOM USE ONLY
DOCUMENT(S) AFFECTED
PURPOSE OR PROBLEM
PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE
MED FORM 5-DEC-09 1401-R-E
AR 70-62 •11 May 2016 B 3301
Jun 26, 2018 4
Stage 1 and 2 Shroud Support, Jacking Hole (T700, T401, T401C, T701C, T701D)
Technical
INTERIM USE OF THIS MEO IS AUTHORIZED
UNTIL AFFECTED DOCUMENT IS UPDATED.
MEO CHANGE TYPE
4) Normal - Can be implemented with normal priorityPRIORITY IMPLEMENTATION CATEGORY
T700 DAX
DMWR 1-2840-248-2 Dated 30 Sept 2014 TTS 187191, BP 6039T61
VEP 18-0156
DOCUMENT CHANGE IS REQUIRED Verification: Hands-On Table-Top None
To provide procedures for the repair of jacking holes in Stage 1 and 2 shroud supports.
BONHAM.ROBI
N.L.1229254100
Digitally signed by
BONHAM.ROBIN.L.12292541
Date: 2018.06.18 10:06:47 -05'00'
MCCORD.MATT
HEW.KIRKLAND.
1275198800
Digitally signed by
MCCORD.MATTHEW.KIRKLA
ND.1275198800
Date: 2018.06.18 10:12:24 -05'00'
Matthew Mccord
PELTIER.JARED.
RYAN.152335277
Digitally signed by
PELTIER.JARED.RYAN.1523
352772 Date: 2018.06.18 15:17:39 -05'00'
Robin L Bonham for Reinhold Horn PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT
CHANGE OR REVISION TO THE PUBLICATION IDENTIFIED ABOVE.
WP NO. PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGES MUST BE GIVEN)
3-1020
3-1021
3-321.n
Fig.
3-288
ADD new step as follows:
. Inspect Usable Limits Max Rep. Limits Corrective Action .
n. Jacking One full thread One full thread Remove loose material.
holes (9) for cumulative cumulative Chase threads to usable missing or damage or damaged or limits (0.192-32 UNF-3B) damaged missing, without missing, with Clean (Table 3-8) and threads high metal. high metal. remove any remaining chips.
Revise figure as shown on page 3 of 4 of this MEO.
Distribution Statement D:- Distribution authorized to Department of Defense and U.S. DoD contractors only to protect critical technology effective as of 26 June 2014. Other requests for this document must be referred to U.S. Army Aviation and Missile Research, Development and Engineering Center, ATTN: RDMR -AEM , Corpus Christi, TX 78419-5211
MED FORM 13 JAN 2017
Continuation Sheet
MEO NO.
PAGE of
WP NO. PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGES MUST BE GIVEN)
MED FORM 15-DEC-09 1401-R-E
3-1027
3-1028
3-323.p
Fig.
3-290
ADD new step as follows:
. Inspect Usable Limits Max Rep. Limits Corrective Action .
p. Jacking One full thread One full thread Remove loose material.
holes (16) for cumulative cumulative Chase threads to usable missing or damage or damaged or limits (0.192-32 UNF-3B) damaged missing, without missing, with Clean (Table 3-8) and threads high metal. high metal. remove any remaining chips.
Revise figure as shown on page 4 of 4 of this MEO.
MED FORM 13 JAN 2017
AR 70-62 •11 May 2016
B 3301
Continuation Sheet
MEO NO.
PAGE of
MED FORM 15-DEC-09 1401-R-E
AR 70-62 •11 May 2016
Figure 3-288. (T700, T401) Stage 1 Turbine Shroud Support; Inspection
MED FORM 13 JAN 2017
Continuation Sheet
MEO NO.
PAGE of
MED FORM 15-DEC-09 1401-R-E
AR 70-62 •11 May 2016
Figure 3-290. (T401C, T701C, T701D) Stages 1 and 2 Turbine Shroud Support; Inspection
MED FORM 13 JAN 2017
File details come from the government source that posted it. Updated .