This document contains a Maintenance Engineering Order (MEO) and a related federal contract solicitation. The MEO provides interim guidance to clarify that heating and cooling instructions for parts installations should specify the use of an arbor press to avoid applying excessive force. The related solicitation seeks the overhaul of rotor, turbine aircraft. The contractor shall furnish all labor, facilities, parts, materials, equipment, tools and data necessary to overhaul a minimum of 5 to a maximum of 414 rotor, turbine aircraft assets per year over 5 years. The rotor, turbine aircraft is a critical safety item requiring overhaul by an approved source in accordance with DFARS 209.270-3. Currently the only known approved source is GE Engine Services, LLC doing business as GE. Proposals are due by the estimated closing date of August 15, 2020 and award will be withheld pending receipt of sufficient funds.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAINTENANCE ENGINEERING ORDER
(AMCOM Reg. 750-2)
MEO NO.
DATE PAGE 1 of
TITLE Tolerances Unless otherwise noted, dimensions are in inches and tolerances are:
Fractional ………………… ± 1/32 Decimal ………………... ± 0.010 Angular ………………… ± ½°
APPLICABILITY CSI Critical Characteristic Affected?
Impact Statement Attached?
REFERENCES FOR RDECOM USE ONLY
DOCUMENT(S) AFFECTED
PURPOSE OR PROBLEM
PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE
MED FORM 5-DEC-09 1401-R-E
AR 70-62 •11 May 2016 B 3182
Apr 27, 2018 1
Heating and Cooling General Practices for Parts Installations (T700, T401, T401C, T701C, T701D)
Technical
INTERIM USE OF THIS MEO IS AUTHORIZED
UNTIL AFFECTED DOCUMENT IS UPDATED.
MEO CHANGE TYPE
4) Normal - Can be implemented with normal priorityPRIORITY IMPLEMENTATION CATEGORY
T700 DAX
DMWR 1-2840-248-1 Dated 30 Sept 2014 TTS 184158, MEC-B336926
DOCUMENT CHANGE IS REQUIRED Verification: Hands-On Table-Top None
Clarify general heating and cooling guidance. Heating and cooling instructions are mandatory when there is specified the use of an arbor press. There is a concern that unmeasured force applied by arbor press could be excessive and cause damage to parts.
BONHAM.ROBI
N.L.1229254100
Digitally signed by
BONHAM.ROBIN.L.12292541
Date: 2018.04.10 11:30:44 -05'00'
MCCORD.MATT
HEW.KIRKLAND.
1275198800
Digitally signed by
MCCORD.MATTHEW.KIRKLA
ND.1275198800
Date: 2018.04.10 11:57:40 -05'00'
Matthew McCord
HORN.REINHOL
D.J.1087783495
Digitally signed by
HORN.REINHOLD.J.1087783
Date: 2018.04.11 14:05:22 -05'00'
Robin L Bonham Reinhold Horn PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT
CHANGE OR REVISION TO THE PUBLICATION IDENTIFIED ABOVE.
WP NO. PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGES MUST BE GIVEN)
3-411
3-21.ad.
(2)
REVISE step as follows:
"(2) Repair part is able to be installed easily (without excessive force or the use of an arbor press)."
Distribution Statement D:- Distribution authorized to Department of Defense and U.S. DoD contractors only to protect critical technology effective as of 26 June 2014. Other requests for this document must be referred to U.S. Army Aviation and Missile Research, Development and Engineering Center, ATTN: RDMR -AEM , Corpus Christi, TX 78419-5211