This document outlines engineering exceptions and product requirements for a federal contract to produce 120mm tank training ammunition. Key details include required drawings and documents to be added, deleted, or revised. Products referenced include primers, propellants, and containers. Notes provide updates to part numbers, sources of supply, and specifications. The related federal contract opportunity is solicitation number W52P1J-21-R-0035 for 120mm tank training ammunition from fiscal year 2022 through 2026. The closing date for proposals is August 6, 2021. The soliciting agency is the Department of the Army Materiel Command Joint Munitions Command.

View the file

Other files

File Type Posted
Attachment 0018 - W52P1J-21-R-0035 Offeror Questions and USG Responses through 11-Aug-2021.pdf PDF
W52P1J21R0035-0004 FINAL.pdf PDF
Attachment 0021 - Appendix 7B - Unitization Procedures for Complete Rounds Packed in Cylindrical Metal Containers on 4-Way....pdf PDF
Attachment 0022 - Basic Procedures - Unitization Procedures for Complete Rounds Packed in Cylindrical Metal or Plastic Containers.pdf PDF
W52P1J21R0035-0003 FINAL.pdf PDF
Attachment 0018 - W52P1J-21-R-0035 Offeror Questions and USG Responses through 05-Aug-2021.pdf PDF
Attachment 0018 - W52P1J-21-R-0035 Offeror Questions and USG Responses through 22-Jul-2021.pdf PDF
W52P1J21R0035-0002 FINAL.pdf PDF
Attachment 0001 - 120mm Tank Training Price Matrix 21July2021.xlsx XLSX spreadsheet
Attachment 0016 - PA171 Drawings 13006756 and 13006757.pdf PDF
W52P1J21R0035-0001 FINAL.pdf PDF
Attachment 0009 - OPSEC Requirements SOW.pdf PDF
Attachment 0005 - Guidance on Documentation of CDRLs.pdf PDF
Attachment 0002 - Contract C Requirements - M1002.pdf PDF
Attachment 0012 - Case Base Inspection Statement of Work (SOW) 29-Nov-2006.pdf PDF
Attachment 0004 - Contract C Requirements - M865A1 Additional.pdf PDF
Attachment 0011 - Hazardous Material Warning.pdf PDF
Exhibit A - Contract Data Requirements List (CDRLs) M1002 and M865A1 24-May-2021.pdf PDF
Attachment 0007 - Configuration Change Management SOW.pdf PDF
W52P1J-21-R-0035 FY22-26 120mm Tank Training Ammunition.pdf PDF
Attachment 0014 - Physical Security SOW.pdf PDF
Attachment 0010 - OPSEC Operations Security Plan - Sample.pdf PDF
Attachment 0013 - Small Business Participation Plan.pdf PDF
Attachment 0006 - GFM Accountability Instructions.pdf PDF
Attachment 0008 - Light and Medium Phosphate Coating Requirements SOW.pdf PDF
Attachment 0001 - 120mm Tank Training Price Matrix 12-May-2021.xlsx XLSX spreadsheet
Attachment 0015 - Past Performance Questionnaire.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTRACT C REQUIREMENTS

ENGINEERING EXCEPTION TEXT (CONTINUED):

PACKAGING:

Drawing 13074476 page 2 Zone C3 missing the “PA171” + Container Lot Number marking. This is just below the rim circumferentially. This marking is required per drawing 12990754.

Dwg13074476 - Note P3 - 12996739-1 should be 12990739-1

AC200000423 (CARC PAINT Drawing) In Note 4.2 SSPC PAINT 25 "…SPECIFICATION PRIMERS SUCH AS TT-P-1757 OR SSPC PAINT 25…" SSPC PAINT 25 is an alternate for TT-P-1757. Use TT-P-1757

AC200000804

Note 6: Change “Suggested” to “Approved”

Remove 13016463, 9386824, 9390375, and 1948-4127 from TDPL

PRODUCT:

DOCUMENT ÿ ADD DELETE FED-STD-191ÿ X -- A-A-50199ÿ X -- Dwg9345265ÿ -- Xÿ

LOCTITE-DRI-2045 -- X

QAP13053630 -- X

All old versions of ASME Y14.5 are still relevant to the drawings that reference them and okay to use for this item.

Document Notes:

DWG8595465ÿDistribution statement Note: Line 4, Office symbol “SFAE-AMO-MAS-

LC”

should say “SFAE-AA-MAS”

DWG12525047ÿApproved sources of supply: Flowserve U.S. INC. contact number should be (903) 885-3151

DWG12525171ÿApproved sources of supply: Remove BASF, Versamine EH-30 no longer available.

DWG12527140ÿASTM D4615 is still acceptable for this material

DWG12527514ÿSource of Supply Phone Number is (302)773-1000

DWG12912409ÿSource of Supply: Hunstman phone number should be (888)564-9318

DWG13053632 and 13053635 QAP13053630 not needed for M865A1

DWG12525184ÿNote 2.H – Change from "MINIMUM CONTRAST RATIO SHALL BE IN

Contract C Requirements Page 2 of 3 Pages

CONTRACT C REQUIREMENTS

ENGINEERING EXCEPTION TEXT (CONTINUED):

ACCORDANCE WITH A-A-208 FOR DRYING OPACITY (HIDING POWER) FOR RESPECTIVE COLOR"

to "MINIMUM CONTRAST RATIO SHALL BE 0.35"

DWG12526669ÿApproved Source(s) of Supply table: Phone number should be (440)899-2950

DWG12953394ÿApproved Source(s) of Supply table: Versamid 115X70 is discontinued DWG13074468ÿNote 7: ">" should be "."

DWG13074466ÿNote 8: Remove "MARKING SHALL NOT BE ON SABOT SEGMENT LINES"

DWG13074470ÿDisregard erroneous geometry depicted at Primer tip and "as per" remark.

ÿ DWG13074472ÿTable B, Perforation Diameter (d):

ÿChange from “0.051 cm (MINIMUM)” ÿChange to “0.058 cm (MINIMUM)” ÿTable B, Average Web:

ÿChange from “0.114 cm (NOMINAL)” ÿChange to “0.112 cm (NOMINAL)”

DWG13033582ÿDrawing is missing Electrode cavity depth dimension of 0.191 + 0.000 ÿTABLE F, Note M: Remove "CONTAINERS CONFORMING TO DRAWING 9345265

ARE QUALIFIED FOR LEVEL A, B, AND C SHIPMENT OF RPD-596 BULK PROPELLANT"

/-0.005

DWGs13033599 and 13033600 - Table 1 'Applicable QAP' & 'Next Assembly' should include 13033580

DWGs13074974 and 13074975 Phone number for Henkel should say “850-571-5100”

DWG13096390ÿNote 3 LOCTITE-DRI-2045 is commercially available

DWGs12525039, 12525044, 12525136 - Expand the next assembly 12525043

QUALITY NOTE:

Qap12527139 - ASTM D2905 is for Reference only.