Attachment 0003 - Contract C Requirements - M865A1.pdf
PDF 140 KB Posted
- Attached to
- 120mm Tank Training Ammunition - FY22-FY26
- Solicitation number
- W52P1J-21-R-0035
About this file
This document outlines engineering exceptions and product requirements for a federal contract to produce 120mm tank training ammunition. Key details include required drawings and documents to be added, deleted, or revised. Products referenced include primers, propellants, and containers. Notes provide updates to part numbers, sources of supply, and specifications. The related federal contract opportunity is solicitation number W52P1J-21-R-0035 for 120mm tank training ammunition from fiscal year 2022 through 2026. The closing date for proposals is August 6, 2021. The soliciting agency is the Department of the Army Materiel Command Joint Munitions Command.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT C REQUIREMENTS
ENGINEERING EXCEPTION TEXT (CONTINUED):
PACKAGING:
Drawing 13074476 page 2 Zone C3 missing the “PA171” + Container Lot Number marking. This is just below the rim circumferentially. This marking is required per drawing 12990754.
Dwg13074476 - Note P3 - 12996739-1 should be 12990739-1
AC200000423 (CARC PAINT Drawing) In Note 4.2 SSPC PAINT 25 "…SPECIFICATION PRIMERS SUCH AS TT-P-1757 OR SSPC PAINT 25…" SSPC PAINT 25 is an alternate for TT-P-1757. Use TT-P-1757
AC200000804
Note 6: Change “Suggested” to “Approved”
Remove 13016463, 9386824, 9390375, and 1948-4127 from TDPL
PRODUCT:
DOCUMENT ÿ ADD DELETE FED-STD-191ÿ X -- A-A-50199ÿ X -- Dwg9345265ÿ -- Xÿ
LOCTITE-DRI-2045 -- X
QAP13053630 -- X
All old versions of ASME Y14.5 are still relevant to the drawings that reference them and okay to use for this item.
Document Notes:
DWG8595465ÿDistribution statement Note: Line 4, Office symbol “SFAE-AMO-MAS-
LC”
should say “SFAE-AA-MAS”
DWG12525047ÿApproved sources of supply: Flowserve U.S. INC. contact number should be (903) 885-3151
DWG12525171ÿApproved sources of supply: Remove BASF, Versamine EH-30 no longer available.
DWG12527140ÿASTM D4615 is still acceptable for this material
DWG12527514ÿSource of Supply Phone Number is (302)773-1000
DWG12912409ÿSource of Supply: Hunstman phone number should be (888)564-9318
DWG13053632 and 13053635 QAP13053630 not needed for M865A1
DWG12525184ÿNote 2.H – Change from "MINIMUM CONTRAST RATIO SHALL BE IN
Contract C Requirements Page 2 of 3 Pages
CONTRACT C REQUIREMENTS
ENGINEERING EXCEPTION TEXT (CONTINUED):
ACCORDANCE WITH A-A-208 FOR DRYING OPACITY (HIDING POWER) FOR RESPECTIVE COLOR"
to "MINIMUM CONTRAST RATIO SHALL BE 0.35"
DWG12526669ÿApproved Source(s) of Supply table: Phone number should be (440)899-2950
DWG12953394ÿApproved Source(s) of Supply table: Versamid 115X70 is discontinued DWG13074468ÿNote 7: ">" should be "."
DWG13074466ÿNote 8: Remove "MARKING SHALL NOT BE ON SABOT SEGMENT LINES"
DWG13074470ÿDisregard erroneous geometry depicted at Primer tip and "as per" remark.
ÿ DWG13074472ÿTable B, Perforation Diameter (d):
ÿChange from “0.051 cm (MINIMUM)” ÿChange to “0.058 cm (MINIMUM)” ÿTable B, Average Web:
ÿChange from “0.114 cm (NOMINAL)” ÿChange to “0.112 cm (NOMINAL)”
DWG13033582ÿDrawing is missing Electrode cavity depth dimension of 0.191 + 0.000 ÿTABLE F, Note M: Remove "CONTAINERS CONFORMING TO DRAWING 9345265
ARE QUALIFIED FOR LEVEL A, B, AND C SHIPMENT OF RPD-596 BULK PROPELLANT"
/-0.005
DWGs13033599 and 13033600 - Table 1 'Applicable QAP' & 'Next Assembly' should include 13033580
DWGs13074974 and 13074975 Phone number for Henkel should say “850-571-5100”
DWG13096390ÿNote 3 LOCTITE-DRI-2045 is commercially available
DWGs12525039, 12525044, 12525136 - Expand the next assembly 12525043
QUALITY NOTE:
Qap12527139 - ASTM D2905 is for Reference only.
Contract C Requirements Page 3 of 3 Pages
File details come from the government source that posted it. Updated .