This document contains engineering exception text for a federal contract opportunity for 120mm Tank Training Ammunition from fiscal year 2022 through 2026. Key requirements include ammunition, drawings, and documents with various engineering exceptions and notes. Products listed include federally standardized documents, drawings, and qualified products. The solicitation number is W52P1J-21-R-0035 for 120mm Tank Training Ammunition, with 15 attachments and 1 exhibit, and a closing date of August 6, 2021 at 12:00pm Central Time. The contracting agency is the Department of the Army Materiel Command Joint Munitions Command.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT C REQUIREMENTS
ENGINEERING EXCEPTION TEXT (CONTINUED):
PACKAGING:
AC200000804
Note 6: Change “Suggested” to “Approved”
Remove 9386824, and 1948-4127 from TDPL
PRODUCT:
DOCUMENT ADD DELETE
FED-STD-191ÿ X -- A-A-50199ÿ X -- DWG12956311ÿ X -- DWG12956312ÿ X -- DWG12956313ÿ X -- DWG12956314ÿ X --ÿ DWG9345265ÿ -- Xÿ
LOCTITE-DRI-2045 -- X
QS13053630 -- X
All old versions of ASME Y14.5 are still relevant to the drawings that reference them and okay to use for this item.
Document Notes:
DWG8595465 - Distribution statement Note: Line 4, Office symbol “SFAE-AMO-MAS-LC” should say “SFAE-AA-MAS”
DWG12525047ÿApproved sources of supply: Flowserve U.S. INC. contact number should be (903) 885-3151
DWG12525171ÿApproved sources of supply: Remove BASF, Versamine EH-30 no longer available.
DWG12525184ÿNote 2.H – Change from "MINIMUM CONTRAST RATIO SHALL BE IN
ACCORDANCE WITH A-A-208 FOR DRYING OPACITY (HIDING POWER) FOR RESPECTIVE COLOR"
to "MINIMUM CONTRAST RATIO SHALL BE 0.35"
DWG12527140ÿASTM D4615 is acceptable for this material
DWG12527514ÿSource of Supply Phone Number is (302)773-1000
DWG12912409ÿSource of Supply: Hunstman phone number should be (888)564-9318
DWG12953394ÿApproved Source(s) of Supply table: Versamid 115X70 is discontinued
Dwg13006740 Parts Table, Find #9, Remarks Column - SAE-AS3528 should be SAE-AS3582
DWG13006747ÿ"ASME Y14.-1994" Should be "ASME Y14.5-1994"
DWG13033582ÿDrawing is missing Electrode cavity depth dimension of 0.191 +0.000/-0.005
DWG13033596ÿTABLE F, Note N: Remove "CONTAINERS CONFORMING TO DRAWING 9345265
Contract C Requirements Page 2 of 3 Pages
CONTRACT C REQUIREMENTS
ENGINEERING EXCEPTION TEXT (CONTINUED):
ARE QUALIFIED FOR LEVEL A, B, AND C SHIPMENT OF RPD-596 BULK PROPELLANT"
DWG13033599 and DWG13033600ÿTable 1 'Applicable QAP' & 'Next Assembly' should include 13033580
DWG13053632ÿNote 5 LOCTITE-DRI-2045 is commercially available
DWG13053635ÿNote 6 “103096390” should say “13096390”
DWG13074974 and DWG13074975 - Phone number for Henkel should say “850-571-5100”
DWG13096390ÿNote 3 LOCTITE-DRI-2045 is commercially available
QS12527139: Use ASTM D2905 as reference only.
Contract C Requirements Page 3 of 3 Pages