Attachment 0002 - Contract C Requirements - M1002.pdf

PDF 139 KB Posted

Attached to
120mm Tank Training Ammunition - FY22-FY26
Solicitation number
W52P1J-21-R-0035
Issued by

About this file

This document contains engineering exception text for a federal contract opportunity for 120mm Tank Training Ammunition from fiscal year 2022 through 2026. Key requirements include ammunition, drawings, and documents with various engineering exceptions and notes. Products listed include federally standardized documents, drawings, and qualified products. The solicitation number is W52P1J-21-R-0035 for 120mm Tank Training Ammunition, with 15 attachments and 1 exhibit, and a closing date of August 6, 2021 at 12:00pm Central Time. The contracting agency is the Department of the Army Materiel Command Joint Munitions Command.

View the file

Other files

File Type Posted
Attachment 0018 - W52P1J-21-R-0035 Offeror Questions and USG Responses through 11-Aug-2021.pdf PDF
W52P1J21R0035-0004 FINAL.pdf PDF
Attachment 0021 - Appendix 7B - Unitization Procedures for Complete Rounds Packed in Cylindrical Metal Containers on 4-Way....pdf PDF
Attachment 0022 - Basic Procedures - Unitization Procedures for Complete Rounds Packed in Cylindrical Metal or Plastic Containers.pdf PDF
W52P1J21R0035-0003 FINAL.pdf PDF
Attachment 0018 - W52P1J-21-R-0035 Offeror Questions and USG Responses through 05-Aug-2021.pdf PDF
Attachment 0018 - W52P1J-21-R-0035 Offeror Questions and USG Responses through 22-Jul-2021.pdf PDF
W52P1J21R0035-0002 FINAL.pdf PDF
Attachment 0001 - 120mm Tank Training Price Matrix 21July2021.xlsx XLSX spreadsheet
Attachment 0016 - PA171 Drawings 13006756 and 13006757.pdf PDF
W52P1J21R0035-0001 FINAL.pdf PDF
Attachment 0009 - OPSEC Requirements SOW.pdf PDF
Attachment 0005 - Guidance on Documentation of CDRLs.pdf PDF
Attachment 0012 - Case Base Inspection Statement of Work (SOW) 29-Nov-2006.pdf PDF
Attachment 0004 - Contract C Requirements - M865A1 Additional.pdf PDF
Attachment 0011 - Hazardous Material Warning.pdf PDF
Exhibit A - Contract Data Requirements List (CDRLs) M1002 and M865A1 24-May-2021.pdf PDF
Attachment 0007 - Configuration Change Management SOW.pdf PDF
W52P1J-21-R-0035 FY22-26 120mm Tank Training Ammunition.pdf PDF
Attachment 0003 - Contract C Requirements - M865A1.pdf PDF
Attachment 0014 - Physical Security SOW.pdf PDF
Attachment 0010 - OPSEC Operations Security Plan - Sample.pdf PDF
Attachment 0013 - Small Business Participation Plan.pdf PDF
Attachment 0006 - GFM Accountability Instructions.pdf PDF
Attachment 0008 - Light and Medium Phosphate Coating Requirements SOW.pdf PDF
Attachment 0001 - 120mm Tank Training Price Matrix 12-May-2021.xlsx XLSX spreadsheet
Attachment 0015 - Past Performance Questionnaire.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTRACT C REQUIREMENTS

ENGINEERING EXCEPTION TEXT (CONTINUED):

PACKAGING:

AC200000804

Note 6: Change “Suggested” to “Approved”

Remove 9386824, and 1948-4127 from TDPL

PRODUCT:

DOCUMENT ADD DELETE

FED-STD-191ÿ X -- A-A-50199ÿ X -- DWG12956311ÿ X -- DWG12956312ÿ X -- DWG12956313ÿ X -- DWG12956314ÿ X --ÿ DWG9345265ÿ -- Xÿ

LOCTITE-DRI-2045 -- X

QS13053630 -- X

All old versions of ASME Y14.5 are still relevant to the drawings that reference them and okay to use for this item.

Document Notes:

DWG8595465 - Distribution statement Note: Line 4, Office symbol “SFAE-AMO-MAS-LC” should say “SFAE-AA-MAS”

DWG12525047ÿApproved sources of supply: Flowserve U.S. INC. contact number should be (903) 885-3151

DWG12525171ÿApproved sources of supply: Remove BASF, Versamine EH-30 no longer available.

DWG12525184ÿNote 2.H – Change from "MINIMUM CONTRAST RATIO SHALL BE IN

ACCORDANCE WITH A-A-208 FOR DRYING OPACITY (HIDING POWER) FOR RESPECTIVE COLOR"

to "MINIMUM CONTRAST RATIO SHALL BE 0.35"

DWG12527140ÿASTM D4615 is acceptable for this material

DWG12527514ÿSource of Supply Phone Number is (302)773-1000

DWG12912409ÿSource of Supply: Hunstman phone number should be (888)564-9318

DWG12953394ÿApproved Source(s) of Supply table: Versamid 115X70 is discontinued

Dwg13006740 Parts Table, Find #9, Remarks Column - SAE-AS3528 should be SAE-AS3582

DWG13006747ÿ"ASME Y14.-1994" Should be "ASME Y14.5-1994"

DWG13033582ÿDrawing is missing Electrode cavity depth dimension of 0.191 +0.000/-0.005

DWG13033596ÿTABLE F, Note N: Remove "CONTAINERS CONFORMING TO DRAWING 9345265

Contract C Requirements Page 2 of 3 Pages

CONTRACT C REQUIREMENTS

ENGINEERING EXCEPTION TEXT (CONTINUED):

ARE QUALIFIED FOR LEVEL A, B, AND C SHIPMENT OF RPD-596 BULK PROPELLANT"

DWG13033599 and DWG13033600ÿTable 1 'Applicable QAP' & 'Next Assembly' should include 13033580

DWG13053632ÿNote 5 LOCTITE-DRI-2045 is commercially available

DWG13053635ÿNote 6 “103096390” should say “13096390”

DWG13074974 and DWG13074975 - Phone number for Henkel should say “850-571-5100”

DWG13096390ÿNote 3 LOCTITE-DRI-2045 is commercially available

QS12527139: Use ASTM D2905 as reference only.

Contract C Requirements Page 3 of 3 Pages