Appendix H1 - BLDG 4 Bid Documents.pdf
PDF 14 MB Posted
- Solicitation number
- IFB1-NHAA-2025000029
- Issued by
- Larimer County, Lakewood City, Colorado
About this file
This document is a detailed architectural bid set for the Fort Lyon Life Safety Corrections project for Building 4, prepared by T.A. Duke & Associates for the Colorado Department of Local Affairs. The project involves comprehensive life safety upgrades and code improvements for Building 4, located in Bent County, Colorado. Specific scope includes modifications to hardware, restrooms, doors, lighting, fire protection systems, and accessibility features across the building's basement, first, and second floors. The total building area is 52,117 gross square feet, and the work will address multiple code deficiencies using the 2021 International Building Code and related standards. The project involves replacing flooring, wall finishes, ceilings, plumbing fixtures, electrical systems, and implementing ADA-compliant design elements.
The project is part of a broader initiative to upgrade buildings at the Fort Lyon Campus, a historic site originally established in 1867 and previously used as a Navy Hospital and Colorado Department of Corrections facility. The current goal is to provide supportive housing and services for homeless veterans. Funding appears to be from state appropriations, with the specific budget not detailed in the document. The architectural plans reveal extensive remediation work, including asbestos removal, fire sprinkler system updates, installation of new doors and hardware, bathroom renovations, and accessibility improvements. The bid documents include comprehensive drawings, specifications, and technical details across architectural, mechanical, electrical, and plumbing disciplines, indicating a thorough and complex renovation project designed to bring the facility into compliance with current building and safety codes.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MARK DATE DESCRIPTION
SHEET TITLE
CONSULTANTS
PROJECT NO: #Project Code
MODEL FILE:
Fort Lyon Bldg 4-life safety.pln
DRAWN BY: TAD
DATE: 20 MARCH 2023
G-001
A
B
C
D
E
/U se rs /ta du ke
/D oc um en ts /A rc hi ca d
Fi le s/ Fo rt Ly on B ld g
4-lif e sa fe ty
.p ln
COVER SHEET
Fort Lyon Life Safety Corrections -
Building 4
Building 4 Fort Lyon, 81054
T.A. DUKE & ASSOCIATES, Inc.
4220 Brigadoon Lane
Colorado Springs, CO 80906 719 648 7722 taduke@earthlink.net
Structural Engineering:
HCDA Engineering, Inc.
9 South Weber Colorado Springs, CO 80903
719 633 7784
MEP Engineering:
McShea Consulting LLC
4445 Northpark Dr., Suite 200 Colorado Springs, CO 80907
719 358 8208
PROJECT NUMBER: 2021-035M21/HB 1408
3/31/23 ISSUED FOR CODE REVIEW
4/13/23 ISSUED FOR STATE REVIEW
4/21/23 CODE COMMENT REVISIONS
6/13/23 ISSUED FOR STATE REVIEW
9/21/2023
7/19/23
ISSUED FOR CODE
CONSULTANT REVIEW
8/23/23
ISSUED FOR CODE
CONSULTANT REVIEW
9/21/23
ISSUED FOR BIDS
Fort Lyon Life Safety Corrections - Building 4
CONSULTANTS
PROJECT NO: #Project Code
MODEL FILE:
Fort Lyon Bldg 4-life safety.pln
DRAWN BY: TAD
DATE: 20 MARCH 2023
G-002
A
B
C
D
E
/U se rs /ta du ke
/D oc um en ts /A rc hi ca d
Fi le s/ Fo rt Ly on B ld g
4-lif e sa fe ty
.p ln
NOTES & ACM REPORT
Fort Lyon Life Safety Corrections -
Building 4
Building 4 Fort Lyon, 81054
T.A. DUKE & ASSOCIATES, Inc.
4220 Brigadoon Lane
Colorado Springs, CO 80906 719 648 7722 taduke@earthlink.net
Structural Engineering:
HCDA Engineering, Inc.
9 South Weber Colorado Springs, CO 80903
719 633 7784
MEP Engineering:
McShea Consulting LLC
4445 Northpark Dr., Suite 200 Colorado Springs, CO 80907
719 358 8208
PROJECT NUMBER: 2021-035M21/HB 1408
3/31/23 ISSUED FOR CODE REVIEW
4/13/23 ISSUED FOR STATE REVIEW
4/21/23 CODE COMMENT REVISIONS
6/13/23 ISSUED FOR STATE REVIEW
9/21/2023
7/19/23
ISSUED FOR CODE
CONSULTANT REVIEW
8/23/23
ISSUED FOR CODE
CONSULTANT REVIEW
9/21/23
ISSUED FOR BIDS
Asbestos Inspection Report Page 9
NOTES:_________________________________________________________________
Building 4
Approximately 11,752 sq. ft. of various colored/patterned ACM sheet vinyl floor coverings exist throughout various locations of the building, (see drawings for locations) (1-15% Chrysotile). This material was in good condition at the time of this inspection exhibiting only minor marks and wearing.
Approximately 20,708 sq. ft. of various colored/patterned, 9” x 9” and 12”x 12” ACM floor tiles and associated adhesives exist throughout various locations of the building, (see drawings for locations), (1-15% Chrysotile). This material was in good condition at the time of this inspection exhibiting only minor breakage and wearing.
Floor tiles and sheet vinyl are normally considered non-friable if the material is in good condition and repair could be performed during routine operations and maintenance activities assuring that the material is not cut, abraded, or in any other way damaged causing release of asbestos fibers or the material must be properly abated prior to renovation/demolition activities.
Approximately 5,200 l.f. of ACM baseboard adhesives exist throughout the building, (see drawings for locations), (2% Chrysotile). This material was in good condition at the time of this inspection. This material should be managed following the facilities Operation & Maintenance Program. The material should be properly abated by a State of Colorado licensed General Abatement Contractor prior to renovation or if the material becomes damaged.
Approximately 3,200 l.f. of ACM Thermal Systems Pipe Insulation (TSI) exists throughout the building and basement/crawlspace, (see drawings for locations), (8-70% Chrysotile). This material was in good to poor condition at the time of this inspection.
GHP inspected/assessed only those materials that were accessible. Access panels were not available for performing a thorough survey of pipe insulation inside wall cavities and/or pipe chases. Pipe insulation inside walls/pipe chases should be assumed to be asbestos containing until determined otherwise. GHP determined that fiberglass insulation is obscuring remnant TSI on pipes. All fiberglass insulation should be assumed to be covering ACM material. Personal protective equipment should be worn by those entering wall cavities/pipe chases. Isolate the areas surrounding pipe chases when performing routine maintenance in these areas. The material in the crawlspace
Asbestos Inspection Report Page 10 exhibited significant damage including dislodged material. The crawlspace soils are considered contaminated. Damaged material should be repaired immediately.
Sample Number Material and Location Asbestos Content B-06505.01-69 Vibration damper – Sample acquired from Building 4 on the southeast corner of attic.
None Detected
B-06505.01-70 12X12 white & tan floor tile – Sample acquired from Building 4 adjacent to the south side elevator directly taken from the corner of the main hallway.
None Detected
B-06505.01-71 Gypsum board with joint compound – Sample acquired from Building 4 in the south hallway where it intersects with main hallway at the south west corner.
None Detected
B-06505.01-72 Felt backing with mastic – Sample acquired from Building 4, room 128 on floor.
None Detected
B-06505.01-73 Spray on fire proofing – Sample acquired from Building 4, room 100 4A taken from the middle of the pipe closet, room located between rooms #104 & #106.
None Detected
B-06505.01-74 Tar paper w/fibrous insulation – Sample acquired from Building 4 in boiler room 3A in basement, taken from the north east portion of the ceiling.
None Detected
B-06505.01-75 Ceiling masonite board – Sample acquired from Building 4 in room 2A in basement, taken directly in the center of the ceiling of room.
None Detected
B-06505.01-76 2’X4’ ceiling tile w/white pinhole pattern – Sample acquired from Building 4 in room 18A.
None Detected
B-06505.01-77 Gypsum board with joint compound with plastic covering – Sample acquired from room 17A in basement, taken at the south west corner of room 4ft up from floor.
None Detected
B-06505.01-78 Ceiling texture – Sample acquired from Building 4, located in basement, taken in pool area at the southeast portion of the ceiling of room.
None Detected
B-06505.01-79 Tan sheet vinyl w/square pattern – Sample acquired from Building 4, room 21A.
25% Chrysotile
B-06505.01-80 Wall plaster with texture – Sample acquired in Building 4 basement, located in rest room 15A, taken at the southwest wall, 4ft up from floor.
None Detected
B-06505.01-81 Black floor adhesive – Sample acquired from Building 4 from threshold of library 8A.
5% Chrysotile
See GHP report 06505.06-Building 4 Partial Abatement.
Abatement Project included Building 4 Mechanical Room (Room #3A). Abatement Contractor (AC) erected a “gross removal” enclosure that encompassed/abated the two tanks present, (approximately 620 sq. ft. ACM TSI), erected several negative pressure secondary containments, and used “glove bag” removal procedures to abate all remaining ACM TSI from all pipes and pipe fittings, (approximately 260 l.f. of 4”-12” OD TSI).
AC also removed/disposed of loose LCP where this condition existed within their immediate work areas and were impacted by asbestos abatement activities.
NOTES:_________________________________________________________________
GOBBELL HAYES ACM REPORT GOBBELL HAYES ACM REPORT
GENERAL NOTES
PROJECT: BUILDING 4 LIFE SAFETY CORRECTIONS
FORT LYON, CO
APPLICABLE CODES:
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL PLUMBING CODE
2020 NATIONAL ELECTRIC CODE
2021 INTERNATIONAL FIRE CODE
NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS
ZONING: NOT APPLICABLE
SEISMIC ZONE: B
SCOPE OF WORK:
MODIFICATIONS TO HARDWARE AND RESTROOMS
TOTAL BUILDING AREA: 52,117 GSF
SEPARATION OF EXITS: 1/3 THE DIAGONAL (BUILDING IS SPRINKLERED)
DIAGONAL @ BASEMENT = 254'
DISTANCE BETWEEN EXITS = 142'
DIAGONAL @ 1ST FLOOR = 254'
DISTANCE BETWEEN EXITS = 142'
DIAGONAL @ 2ND FLOOR = 254'
DISTANCE BETWEEN EXITS = 142'
CODE NOTES
12. DURING AND AT THE COMPLETION OF THE CONTRACTORS
DAILY WORK, CONTRACTORS ARE RESPONSIBLE FOR THE
CLEANING UP AND REMOVAL OF ALL RUBBISH AND DEBRIS
BEFORE LEAVING THE JOBSITE.
13. THE FOLLOWING ARE STRICTLY PROHIBITED WORK AND
PRACTICES:
A. ANY COMBUSTIBLE MATERIALS ABOVE FINISHED
CEILING
B. IMPOSING ANY STRUCTURAL LOAD, TEMPORARY OR
PERMANANT, ON ANY PART OF THE BUILDING
STRUCTURE WITHOUT PRIOR WRITTEN APPROVAL
C. CUTTING ANY HOLES IN FLOOR SLABS, WALLS OR ROOF
WITHOUT PROPER APPROVAL.
14. CONTRACTORS SHALL CARRY ADEQUATE LIABILITY INSURANCE
AS SET FORTH BY OWNER'S REQUIREMENTS.
15. A CERTIFICATE OF OCCUPANCY MUST BE OBTAINED UPON
COMPLETION OF ALL WORK AND FINAL INSPECTIONS. THE ORIGINAL
C.O. TO BE SUBMITTED TO OWNER
16. IN EVENT OF CONFLICT, DISCREPENCY, OBLIGATION, ETC.
CONTRACTOR TO CONTACT ARCHITECT AND OWNER
FOR CLARIFICATION PRIOR TO PROCEEDING.
17. PROVIDE ALL INSURANCE, LICENSES, BONDING AND RELEASE
OF LIENS REQUIRED BY OWNER. PROVIDE COPIES
OF ALL DOCUMENTATION UPON REQUEST.
18. PROVIDE COMPLETE OPERATING MAINTENANCE AND
SPECIFICATION MANUALS TO STAGE FOR ALL EQUIPMENT WITHIN
(15) DAYS OF FINAL COMPLETION OF JOB.
19. PROVIDE A WRITTEN LIST OF SERVICE SUB-CONTRACTORS TO
OWNER INCLUDING NAMES, ADDRESSES, PHONE NUMBERS AND
CONTACT PERSONS FOR FUTURE SERVICE NEEDS WITHIN (15) DAYS
OF COMPLETION OF JOB.
20. CONTRACTORS SHALL NOT BE ALLOWED TO USE, STORE OR
DISPOSE OF ANY HAZARDOUS, FLAMMABLE, EXPLOSIVE,
RADIOACTIVE TOXIC, CONTAMINATING, POLLUTING MATERIALS
OR SUBSTANCES RELATED TO INJUROUS OR CHEMICALLY
REGULATED MATERIALS ON THE JOB SITE.
21. ALL INTERIOR WALLS SHALL HAVE A MINIMUM OF ONE COAT OF
WHITE PRIMER INSTALLED AND TWO FINISH COATS.
22. GENERAL CONTRACTOR IS TO CONSTRUCT INTERIOR WALLS
FROM STEEL STUDS. GENERAL CONTRACTOR MUST USE FIRE
RETARDANT TREATED WOOD BLOCKING AT CRITICAL LOCATIONS
FOR THE MOUNTING OF MILLWORK, OR ACCESSORIES
23. ARCHITECTURAL SIGNAGE FOR TOILETS, EXITS, OTHER CODE
RELATED SIGNS NECESSARY SHALL BE FURNISHED AND INSTALLED
BY THE CONTRACTOR.
24. GENERAL CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION
OF ANY TENANT SUPPLIED MATERIALS, FIXTURES, ETC. ON JOB SITE.
25.GENERAL CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS.
ANY DIMENSIONS SHOWN WHICH INDICATE AN EXISTING CONDITION
ARE APPROXIMATE AND SHOULD BE VERIFIED ON SITE.
26. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE
THE EXISTING CONDITIONS WHICH MAY AFFECT THE COMPLETION OF
THE PROJECT IN ACCORDANCE WITH THE CONSTRUCTION
DOCUMENTS. NOTIFY THE ARCHITECT IF EXISTING CONDITIONS VARY
SUCH THAT IMPLEMENTATION OF THE DOCUMENTS WILL ADVERSLY
AFFECT THE PROJECT COST OR PROJECT SCHEDULE.
27. NOT USED
32. PROVIDE OWNER WITH A MINIMUM OF ONE (1) SET OF "AS-BUILT"
DRAWINGS INDICATING ALL VARIANCES BETWEEN ORIGINAL
APPROVED CONSTRUCTION DOCUMENTS AND ACTUAL COMPLETED
CONSTRUCTION.
33. IN THE EVENT THAT CERTAIN FEATURES OF THE CONSTRUCTION
ARE NOT FULLY SHOWN ON THE DRAWINGS OR CALLED FOR IN
GENERAL NOTES, THEN THERE CONSTRUCTION SHALL BE OF THE
SAME CHARACTER AS FOR SIMILAR CONDITIONS.
34. ARCHITECT AND OWNER SHALL INSPECT THE PROJECT TO
VERIFY STATUS OF COMPLETION WITH REASONABLE PROMPTNESS
AFTER NOTIFICATION BY CONTRACTOR.
35. CONTRACTOR TO PROVIDE ALL CIVIL, ELECTRICAL, AND
MECHANICAL ASSOCIATED WITH THE DESIGN INTENT SHOWN
ON THE ARCHITECTURAL AND ENGINEERING DRAWINGS
30. CONTRACTOR SHALL MAINTAIN REQUIRED DOCUMENTS AND UP
TO DATE CONSTRUCTION PLANS ON THE JOB SITE.
31. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL
CLEANING PRIOR TO TURNING THE SPACE OVER TO THE OWNER.
CLEANING SHALL INCLUDE, BUT NOT BE LIMITED TO: REMOVAL OF
GREASE MASTIC ADHESIVES, DUST, DIRT, STAINS, FINGERPRINTS,
LABELS AND OTHER FOREIGN MATERIALS FROM EXPOSED
INTERIOR AND EXTERIOR SURFACES. PRESSURE WASH EXTERIOR
PAVED SURFACES.
28. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY
DAMAGE TO THE FACILITY DURING CONSTRUCTION.
29. CONTRACTOR SHALL PROPERLY DISPOSE OF ALL DEMOLISHED
MATERIALS IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS.
36. SHOULD CONTRACTOR, IN PREPARING HIS BID OR AT ANY TIME
THEREAFTER, FIND ANY DISCREPANCY, INCONSISTENCY, CONFLICT
OR OMISSION IN, OR BE IN DOUBT AS TO THE EXACT MEANING
OF THE DRAWINGS OR SPECIFICATIONS HE SHALL IMMEDIATELY
AND BEFORE PROCEEDING FURTHER NOTIFY OWNER IN WRITING.
OWNER WILL IMMEDIATELY RESOLVE SUCH DISCREPANCY AND
FURNISH CONTRACTOR WITH WRITTEN INSTRUCTIONS WITH
RESPECT THERETO. IT WILL NOT BE A DISCREPANCY IF THESE SPECS
DO NOT MENTION PORTIONS OF THE WORK WHICH THE DRAWINGS
COMPETENTLY EXPLAIN.
1. ALL NEW CONSTRUCTION SHALL BE IN STRICT COMPLIANCE
WITH NATIONAL, STATE, COUNTY AND CITY BUILDING CODES AND
THE AMERICANS WITH DISABILIITIES ACT (A.D.A) REGULATIONS.
2. ALL WORK SHALL BE DONE IN COMPLIANCE WITH THE
OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)
3. DIMENSIONS GIVEN IN FIGURES ON THE PLANS SHALL TAKE
PRECEDENCE OVER SCALED DIMENSIONS. ALL DIMENSIONS
SHALL BE VERIFIED IN FIELD. DIMENSIONS ARE NOT
ADJUSTABLE UNLESS NOTED OTHERWISE.
4. ALL DIMENSIONS ARE GIVEN FROM FACE OF DRYWALL
TO FACE OF DRYWALL UNLESS NOTED OTHERWISE.
5. "EQUAL" WHEN USED SHALL MEAN AN EQUIVALENT PRODUCT
OR MATERIAL AS APPROVED BY THE TENANT.
6. ALL HEIGHTS ARE DIMENSIONED FROM FINISHED FLOOR
UNLESS NOTED OTHERWISE.
7. THE CONTRACTOR SHALL VERIFY THAT NO CONFLICTS
EXIST IN LOCATIONS OF ANY AND ALL MECHANICAL,
TELEPHONE/DATA, ELECTRICAL, LIGHTING, PLUMBING AND
SPRINKLER EQUIPMENT (TO INCLUDE ALL PIPING, DUCTWORK
AND CONDUIT) AND THAT ALL REQUIRED CLEARANCES FOR
INSTALLATION OR MAINTENANCE OF THE ABOVE EQUIPMENT
IS PROVIDED.
8. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED, BEDDED
AND SANDED SMOOTH WITH NO VISIBLE JOINTS. ALL CORNERS
SHALL RECEIVE METAL CORNER BEAD UNLESS OTHERWISE
NOTED
9. ALL RATED WALLS SHALL HAVE THEIR RATING MAINTAINED
AND ALL NEW PENETRATIONS SEALED TO MEET CURRENT
CODE REQUIREMENTS.
10. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE FREE
FROM DEFECTS. ALL MATERIALS AND WORKMANSHIP SHALL
BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE
OF ACCEPTANCE. DURING THIS PERIOD, PROBLEMS DUE TO
DEFECTIVE MATERIALS OR FAULTY WORKMANSHIP SHALL BE
CORRECTED AT NO COST TO THE TENANT. ANY PROBLEMS
THAT OCCUR DURING CONSTRUCTION SHALL BE CORRECTED
IMMEDIATELY TO THE SATISFACTION OF THE TENANT.
11. GENERAL CONTRACTOR SHALL PROVIDE ADEQUATE BRACIING
AS REQUIRED TO SECURE WORK TO STRUCTURE ABOVE CEILING
WHERE REQUIRED AND SHALL BE TOTALLY RESPONSIBLE FOR
HIS WORK.
DRAWING LISTING
ARCHITECTURAL DRAWINGS:
SHEET # NAME
G-001 COVER SHEET
G-002 NOTES
G-003 BASEMENT CODE STUDY PLAN
G-004 1ST FLOOR CODE STUDY PLAN
G-005 2ND FLOOR CODE STUDY PLAN
AS-001 VICINITY MAP
AS-002 BUILDING LOCATION PLAN
AS-003 SURVEY/PLAT MAP
A-101 BASEMENT DEMO PLAN
A-102 1ST FLOOR DEMO PLAN
A-103 2ND FLOOR DEMO PLAN
A-104 BASEMENT FLOOR PLAN
A-105 1ST FLOOR PLAN
A-106 2ND FLOOR PLAN
A-107 BASEMENT REFLECTED CEILING PLAN
A-108 1ST FLOOR REFLECTED CEILING PLAN
A-109 2ND FLOOR REFLECTED CEILING PLAN
A-201 INTERIOR ELEVATIONS
A-202 INTERIOR ELEVATIONS
A-401 ENLARGED PLANS
A-501 ACCESSORY SPEC SHEETS AND SIGNAGE DETAILS
A-502 DETAILS AND SPEC SHEETS
A-503 SMOKE DETECTOR AND FIRE ANNUNCIATOR SPECS
A-504 FIRE SPRINKLER SYSTEM DEFICIENCIES ABD EDF SPEC
A-505 FIRE STOP DETAILS
A-601 DOOR SCHEDULE
A-602 DOOR SCHEDULE
A-603 DOOR SCHEDULE
A-604 DOOR SCHEDULE
A-605 DOOR SCHEDULE
A-606 DOOR SCHEDULE
A-607 DOOR SCHEDULE
A-608 DOOR SCHEDULE
A-701 BASEMENT FINISH PLAN
A-702 1ST FLOOR FINISH PLAN
A-703 2ND FLOOR FINISH PLAN
A-704 FINISH SPECS AND LEGEND
A-705 FINISH SPECS
MEP DRAWINGS:
M0.1 MECHANICAL NOTES AND SCHEDULES
M1.1 LOWER LEVEL MECHANICAL PLAN
M2.1 1ST FLOOR MECHANICAL PLAN
M3.1 2ND FLOOR MECHANICAL PLAN
P0.1 PLUMBING NOTES, SCHEDULES AND DETAILS
P1.1 LOWER LEVEL PLUMBING PLAN
P2.1 1ST FLOOR PLUMBING PLAN
P3.1 2ND FLOOR PLUMBING PLAN
E0.1 ELECTRICAL NOTES AND SCHEDULES
E1.1 LOWER LEVEL ELECTRICAL PLAN
E2.1 1ST FLOOR ELECTRICAL PLAN
E3.1 2ND FLOOR ELECTRICAL PLAN
STRUCTURAL DRAWINGS:
S101 GENERAL NOTES AND DETAILS
C. ALL PLUMBING FIXTURES, CONT'D
3. ALL NEW RESTROOM FIXTURES, CONT'D
C. STANDARD LAVATORY
D. ADA LAVATORY
E. TOILET PARTITIONS/URINAL SCREEN
F. STANDARD URINAL
G. ADA URINAL
H. SHOWER UNIT
D. ALL RESTROOM SIGNAGE
E. EXHAUST FAN
F. ALL DOORS AND HARDWARE INCLUDING:
1. ALL NEW DOORS INCLUDING
A. HOLLOW METAL DOORS
B. SOLID CORE WOOD DOORS
2. LEVER LOCKSET
3. LEVER PRIVACY SET
4. LEVER PASSAGE SET
5. PANIC HARDWARE
6. AUTOMATIC CLOSER
7. HINGES
8. DOOR FRAME
G. PORTABLE FIRE EXTINGUISHER
THE FOLLOWING MATERIALS REQUIRE SUBMITTALS PRIOR TO
PROCUREMENT OR INSTALLATION:
A. ALL FINISH MATERIALS INCLUDING:
1. WALL FINISHES INCLUDING:
A. PRIMER PAINT
B. FINISH PAINT
C. CERAMIC WALL TILE
D. VINYL WALL COVERING
2. FLOOR COVERINGS INCLUDING
A. CERAMIC FLOOR TILE
B. CARPET
C. SHEET VINYL
D. VINYL TILE
3. ALL CEILING TILE INCLUDING
A. 2 X 4 TILE
B. 2 X 2 TILE
B. ALL ELECTRCAL ITEMS INCLUDING:
1. 2 X 4 LIGHT FIXTURES
2. 1 X 4 LIGHT FIXTURES
3. EMERGENCY EXIT/LIGHT COMBO UNIT
4. CEILING MOUNTED FIRE ANNUNCIATOR
5. WALL MOUNTED FIRE ANNUNCIATOR
6. ILLUMINATED EXIT SIGNAGE
SUBMITTAL REQUIREMENTS
GENERAL NOTES GENERAL NOTES GENERAL NOTES PARTITION TYPES
Partition Type 13: 4" metal stud (Clark Dietrich ProStud 20) @ 24" O.C. from floor to underside of structure; (1) layer of 5/8" Sheetrock Brand Mold Tough Firecode X Panel at Restroom/wet side and 5/8" type X gyp board at opposite side. Total wall thickness = 5 1/4";
install 3 1/2" batt insulation from floor to top of wall
Partition Type 14: 3 5/8" metal stud (Clark Dietrich ProStud 20) @ 24" O.C. from floor to underside of structure; provide 5/8" type X gyp board at both sides.
Total wall thickness = 4 7/8"; install 3 1/2" batt insulation from floor to top of wall. (1) hour rated - UL Des U419
Partition Type 15: 4" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to underside of structure; provide 5/8" type X USG Durock Brand Glass-Mat Tile Backerboard at both sides. Install 3 1/2" batt insulation from floor to top of wall. Total wall thickness = 5 1/4"
Partition Type 16: 2 1/2" metal stud (Clark Dietrich ProStud 20) @ 24" O.C. from floor to height of adjacent wall or opening; provide 5/8" type X gyp board at exposed side. 2 1/2" batt Insulation; Total wall thickness = 3 1/8"
Partition Type 12: 4" metal stud (Clark Dietrich ProStud 20) @ 24" O.C. from floor to underside of structure; provide 5/8" type X gyp board at one side and
(1) layer of 5/8" type X USG Durock Brand Glass-Mat Tile Backerboard at Restroom side. Total wall thickness = 5 1/4"; install 3 1/2" batt insulation from floor to top of wall. (1) hour rated - UL Des U419
Partition Type 17: 3 5/8" metal stud (Clark Dietrich ProStud 20) @ 24" O.C. from floor to underside of structure; provide 5/8" type X gyp board at one side and
(1) layer of 5/8" type X USG Durock Brand Glass-Mat Tile Backerboard at Restroom side. Total wall thickness = 4 7/8"; install 3 1/2" batt insulation from floor to top of wall
Partition Type 18: 2 1/2" metal stud (Clark Dietrich ProStud 20) @ 24" O.C. from floor to height of adjacent wall; (1) layer of 5/8" type X USG Durock Brand Glass-Mat Tile Backerboard at Restroom side. 2 1/2" batt Insulation;
Total wall thickness = 3 1/8"
Partition Type 19: 4" metal stud (Clark Dietrich ProStud 20) @ 24" O.C. from floor to underside of structure; provide (1) layer of 5/8" Sheetrock Brand Mold Tough Firecode X Panel at exposed side. Total wall thickness = 4 5/8"; install 3 1/2" batt insulation from floor to top of wall
Partition Type 1: 3 5/8" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to underside of structure; provide 5/8" type X gyp board at both sides. Total wall thickness = 4 7/8"; (1) hour rated - UL Des U419
Partition Type 2: 4" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to underside of structure;
provide 5/8" type X gyp board at both sides. Total wall thickness = 5 1/4"; install 3 1/2" batt insulation from floor to top of wall; (1) hour rated - UL Des U419
Partition Type 3: 4" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to top of opening or adjacent wall; provide 5/8" type X gyp board at both sides. Total wall thickness = 5 1/4"; install 3 1/2" batt insulation from floor to top of wall
Partition Type 5: 4" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to underside of structure;
provide 5/8" type X gyp board at both sides. Total wall thickness = 5 1/4" (1) hour rated - UL Des U419
Partition Type 6: 4" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to top of opening or underside of structure; provide 5/8" type X gyp board at one side and 5/8" type X USG Durock Brand Glass-Mat Tile Backerboard at Restroom side. Total wall thickness = 5 1/4"; install 3 1/2" batt insulation from floor to top of wall.
(1) hour rated - UL Des 419
Partition Type 4: 4" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to height of opening or adjacent wall; provide 5/8" type X gyp board at exposed side. Total wall thickness = 4 5/8"
7 Partition Type 7: 4" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to height of adjacent wall;
provide 5/8" type X USG Durock Brand Glass-Mat Tile Backerboard at exposed side. 3 1/2" batt Insulation; Total wall thickness = 4 5/8"
Partition Type 8: 4" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to height of adjacent wall or opening; provide (1) layer 5/8" type X gyp board at each side; Total wall thickness = 5 1/4"
Partition Type 9: 4" CT metal stud (Clark Dietrich 400CT-33) @ 24" O.C. from floor to structure above;
provide (2) layers 1/2" type X gyp board at exposed side and (1) layer of 1" shaftliner panels at shaft side. 3 1/2" batt Insulation; Total wall thickness = 6". (2) Hour rated - UL Des U438
Partition Type 10: 4" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to underside of structure;
provide (2) layers 5/8" type X gyp board at each side. 3 1/2" batt Insulation; Total wall thickness = 6 1/2"
(2) hour rated - UL Des U438
PARTITION TYPES
Partition Type 11: 4" metal stud (Clark Dietrich ProStud 20) @ 24" O.C. from floor to underside of structure; provide 5/8" Sheetrock Brand Mold Tough Firecode X Panel at each side Total wall thickness = 5 1/4"
37. ALL PIPING PENETRATIONS THROUGH FLOORS SHALL BE
SEALED WATER TIGHT BY GROUTING PERIMETER GAP BETWEEN
PIPE AND FLOOR STRUCTURE OR BY USING APPROVED UL SLEEVE
AND SEALER SYSTEM. PENETRATIONS OF RATED WALLS SHALL
USE SLEEVE WITH UL APPROVED FIRE SEALANT PER SECTION
714.4.1.1 OF THE 2021 IBC. PENETRATIONS THROUGH FLOORS
SHALL COMPLY WITH SECTION 714.5.1.1 OR 714.5.1.2” .
38. FLOOR PENETRATIONS CONTAINED AND LOCATED WITHIN THE
CAVITY OF A WALL ABOVE OR BELOW THE FLOOR DO NOT REQUIRE
A T RATING PER SECTION 714.5.1.2 EXCEPTION 1. FLOOR
PENETRATIONS BY FLOOR DRAINS, TUB DRAINS OR SHOWER
DRAINS CONTAINED AND LOCATED WITHIN THE CONCEALED SPACE
OF A HORIZONTAL ASSSEMBLY DO NOT REQUIRE A T RATING PER
SECTION 714.5.1.2 EXCEPTION 2
Partition Type 20: 4" metal stud (Clark Dietrich ProStud
20) @ 24" O.C. from floor to underside of ceiling; provide 5/8" type X USG Durock Brand Glass-Mat Tile Backerboard at both sides. Install 3 1/2" batt insulation from floor to top of wall. Total wall thickness = 5 1/4"
CONSTRUCTION TYPE: NON CONFORMING TYPE IIB (SPRINKLERED)
NOTE: ALL NEW INTERIOR CONSTRUCTION WILL
MEET OR EXCEED FIRE RESISTIVE MATERIALS
REQUIRED BY TYPE IIB CONSTRUCTION
INTERIOR FINISH FIRE RATING:
OCCUPANCY EXIT ENCLOSURES CORRIDORS INTERIOR ROOMS
A-3 B B C B B B C I-1 B C C S C C C
CLASS A: FLAME SPREAD INDEX 0-25; SMOKE DEVELOPED INDEX 0-450
CLASS B: FLAME SPREAD INDEX 26-75; SMOKE DEVELOPED INDEX 0-450
CLASS C: FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED INDEX 0-450
FIRE RESISTANCE RATING (HOURS):
PRIMARY STRUCTURAL FRAME: 0
EXTERIOR BEARING WALLS: 0
INTERIOR BEARING WALLS: 0
INTERIOR NON BEARING WALLS: 0
FLOOR CONSTRUCTION AND
SECONDARY MEMBERS: 0
ROOF CONSTRUCTION AND
SECONDARY MEMBERS: 0
CODE NOTES
B. ALL ELECTRCAL ITEMS INCLUDING, CONT'D:
7. ALL CEILING TILE INCLUDING
A. 2 X 4 TILE
B. 2 X 2 TILE
8. SMOKE DETECTOR
9. CEILING MOUNTED EXIT DIRECTIONAL SIGN
10. WALL MOUNTED EXIT DIRECTIONAL SIGN
11. WALL MOUNTED EMERGENCY LIGHT
C. ALL PLUMBING FIXTURES INCLUDING:
1. RESTROOM ACCESSORIES INCLUDING
A. MIRROR
B. GRAB BARS
C. TOILET TISSUE DISPENSER
D. TOILET SEAT COVER DISPENSER
E. BABY CHANGING STATION
F. SOAP DISPENSER
G. WASTE RECEPTACLE/PAPER TOWEL
DISPENSER
2. DRINKING FOUNTAINS
3. ALL NEW RESTROOM FIXTURES INCLUDING:
A. STANDARD TOILET
B. ADA TOILET
SUBMITTAL REQUIREMENTS SUBMITTAL REQUIREMENTS
ACM NOTES
1. IT IS NOT WITHIN THE SCOPE OF WORK OF THE ARCHITECT TO
DISCOVER, LOCATE, HANDLE, REMOVE OR DISPOSE OF ANY
HAZARDOUS MATERIALS INCLUDING, BUT NOT LIMITED TO: ASBESTOS,
ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB),
HYDROCARBONS OR ANY OTHER TOXIC SUBSTANCES. SHOULD THE
G.C. OR ANY OTHER ENTITY WORKING ON BEHALF OF THE G.C. OR
THE OWNER DISCOVER OR ENCOUNTER ANY HAZARDOUS
MATERIALS, THE G.C. SHALL NOTIFY THE APPROPRIATE AUTHORITIES
IMMEDIATELY AND PROCEED IN ACCORDANCE WITH ALL APPLICABLE
LAWS AND REGULATIONS.
2. ALL MATERIALS BEING REMOVED FROM THE SITE SHALL BE
TESTED FOR ACM PRIOR TO ANY DEMOLITION WORK. IF MATERIAL
TESTS POSITIVE FOR ACM (ASBESTOS CONTAINING MATERIALS),
AREA MUST BE CLEARED OF ALL ACM CONTAINING MATERIALS
AFFECTED BY CONSTRUCTION PRIOR TO DEMOLITION
OR CONSTRUCTION
3. ANY ABATEMENT OF ACM SHALL BE ACCOMPLISHED BY A
CONTRACTOR LICENSED BY THE STATE OF COLORADO
FOR ACM REMOVAL AND COMPLY WITH ALL STATE AND LOCAL
REQUIREMENTS.
4. ALL ACM SHALL BE PROPERLY DISPOSED OF ACCORDING
TO REGULATIONS DEFINED BY THE STATE OF COLORADO
5. ALL MATERIAL BEING INSTALLED IN THE PROJECT,
INCLUDING GYP BOARD, JOINT COMPOUND, VINYL TILE,
SHEET VINYL, CEILING TILE, PLASTER, CARPET, BASE
ADHESIVE OR ANY OTHER MATERIAL BEING PROPOSED
SHALL BE TESTED FOR ACM. A REPORT SHALL BE GIVEN
TO THE OWNER INDICATING RESULTS OF ACM TESTING
CONSULTANTS
PROJECT NO: #Project Code
MODEL FILE:
Fort Lyon Bldg 4-life safety.pln
DRAWN BY: TAD
DATE: 20 MARCH 2023
G-003
A
B
C
D
E
/U se rs /ta du ke
/D oc um en ts /A rc hi ca d
Fi le s/ Fo rt Ly on B ld g
4-lif e sa fe ty
.p ln
OCCUPANCY/PLUMBING
CALCULATIONS
Fort Lyon Life Safety Corrections -
Building 4
Building 4 Fort Lyon, 81054
T.A. DUKE & ASSOCIATES, Inc.
4220 Brigadoon Lane
Colorado Springs, CO 80906 719 648 7722 taduke@earthlink.net
Structural Engineering:
HCDA Engineering, Inc.
9 South Weber Colorado Springs, CO 80903
719 633 7784
MEP Engineering:
McShea Consulting LLC
4445 Northpark Dr., Suite 200 Colorado Springs, CO 80907
719 358 8208
PROJECT NUMBER: 2021-035M21/HB 1408
3/31/23 ISSUED FOR CODE REVIEW
4/13/23 ISSUED FOR STATE REVIEW
4/21/23 CODE COMMENT REVISIONS
6/13/23 ISSUED FOR STATE REVIEW
9/21/2023
7/19/23
ISSUED FOR CODE
CONSULTANT REVIEW
8/23/23
ISSUED FOR CODE
CONSULTANT REVIEW
9/21/23
ISSUED FOR BIDS
TOTAL NUMBER OF SLEEPING UNITS WITH RESTROOMS: 22
TOTAL NUMBER OF RESTROOM FIXTURES NOT ACCESSIBLE
THRU OFFICES OR RESIDENT ROOMS:
TOTAL FLOOR AREA = 17,351 GSF
PLUMBING FIXTURES REQUIRED:
OCCUPANT LOAD CALCULATION:
1ST FLOOR:
A-3 OCCUPANCY: 1,513 NSF/15 NSF = 100.87 OCCUPANTS
100.87 OCCUPANTS / 2 = 50.435 OCCUPANT LOAD PER SEX
PER IBC TABLE 2902.1: ASSEMBLY OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
MALE WC FEMALE WC LAVS
1/125 1/65 1/200
A-3 (READING ROOMS) MINIMUM REQUIRED FIXTURES:
50.435 OCCUPANT LOAD/125 OCCUPANTS PER WC = .403 MALE
50.435 OCCUPANT LOAD/65 OCCUPANTS PER WC = .776 FEMALE
50.435 OCCUPANT LOAD/200 OCCUPANTS PER LAV =.252 MALE
50.435 OCCUPANT LOAD/200 OCCUPANTS PER LAV =.252 FEMALE
B OCCUPANCY: 711 GSF/150 GSF = 4.74 OCCUPANTS
4.74 OCCUPANTS / 2 = 2.37 OCCUPANT LOAD PER SEX
PER IBC TABLE 2902.1: BUSINESS OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
MALE WC FEMALE WC LAVS
1/25 FOR 1ST 50 1/25 FOR 1ST 50 1/40 FOR 1ST 80
AND 1 PER 50 FOR AND 1 PER 50 FOR AND 1 PER 80 FOR
THE REMAINDER THE REMAINDER THE REMAINDER
EXCEEDING 50 EXCEEDING 50 EXCEEDING 80
B MINIMUM REQUIRED FIXTURES:
2.37 OCCUPANT LOAD/25 OCCUPANTS PER WC = .095 MALE
2.37 OCCUPANT LOAD/25 OCCUPANTS PER WC = .095 FEMALE
2.37 OCCUPANT LOAD/40 OCCUPANTS PER LAV = .059 MALE
2.37 OCCUPANT LOAD/40 OCCUPANTS PER LAV = .059 FEMALE
I-1 OCCUPANCY: 10,228 GSF/120 GSF = 85.23 OCCUPANTS
BUILDING 4 HAS WOMEN ONLY IN RESIDENT AREAS
PER IBC TABLE 2902.1: INSTITUTIONAL OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
FEMALE WC LAVS
1/10 1/10
I-1 MINIMUM REQUIRED FIXTURES:
85.23 OCCUPANT LOAD/10 OCCUPANTS PER WC = 8.523 FEMALE
85.23 OCCUPANT LOAD/10 OCCUPANTS PER LAV = 8.523 FEMALE
U OCCUPANCY: 260 GSF/300 GSF = .867 OCCUPANTS
.867 OCCUPANTS / 2 = .434 OCCUPANT LOAD PER SEX
PER IBC TABLE 2902.1: STORAGE OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
MALE WC FEMALE WC LAVS
1/100 1/100 1/100
U MINIMUM REQUIRED FIXTURES:
.434 OCCUPANT LOAD/100 OCCUPANTS PER WC = .004 MALE
.434 OCCUPANT LOAD/100 OCCUPANTS PER WC = .004 FEMALE
.434 OCCUPANT LOAD/100 OCCUPANTS PER LAV = .004 MALE
.434 OCCUPANT LOAD/100 OCCUPANTS PER LAV = .004 FEMALE
NOTE:
PER 2902.1.1: TO DETERMINE OCCUPANT LOAD OF EACH SEX, THE TOTAL
OCCUPANT LOAD SHALL BE DIVIDED IN HALF. …. FOR CALCULATIONS
INVOLVING MULTIPLE OCCUPANCIES, SUCH FRACTIONAL NUMBERS FOR
EACH OCCUPANCY SHALL BE FIRST SUMMED AND THEN ROUNDED UP TO
THE NEXT WHOLE NUMBER
BUILDING 4 HAS WOMEN ONLY IN RESIDENT AREAS
THE MAXIMUM POPULATION OF RESIDENTS IS CURRENTLY
CONTRACTUALLY LIMITED TO LESS THAN 245 FOR THE ENTIRE FACILITY.
THE ACTUAL I-1 OCCUPANCY IS LIMITED BY THE NUMBER OF
RESIDENT ROOMS TO APPROXIMATELY 48 RESIDENTS
ON THIS FLOOR
TOTAL NUMBER OF MALE WC REQUIRED:
A-3 .403 B .095 I-1 0 U .004
TOTAL: .502 = 1 WC
TOTAL NUMBER OF FEMALE WC REQUIRED:
A-3 .776 B .095 I-1 8.523 U .004
TOTAL: 9.398 = 10 WC
TOTAL NUMBER OF MALE LAVS REQUIRED:
A-3 .252 B .059 I-1 0 U .004
TOTAL: .315 = 1 LAV
TOTAL NUMBER OF FEMALE LAVS REQUIRED:
A-3 .252 B .059 I-1 8.523 U .004
TOTAL: 8.838 = 9 LAVS
WC'S PROVIDED (PUBLIC)
WOMEN: 3
MEN: 1 (+ 1 URINAL)
UNISEX: 1
WC'S PROVIDED (NON-PUBLIC))
WOMEN: 14
MEN: 0
UNISEX: 1
LAV'S PROVIDED (PUBLIC):
WOMEN: 3
MEN: 1
UNISEX: 1
LAV'S PROVIDED (NON-PUBLIC):
WOMEN: 14
MEN: 0
UNISEX: 1
SHOWER/TUB REQUIREMENTS I-1 OCCUPANCY:
TOTAL NUMBER OF POTENTIAL RESIDENTS =
I-1 OCCUPANTS 82.9
REQUIRED SHOWER UNITS = 1 SHOWER PER 8 RESIDENTS
83/8 = 11 SHOWERS REQUIRED
TOTAL NUMBER OF SHOWER UNITS PROVIDED = 18
PLUMBING CALCULATIONS PLUMBING CALCULATIONS PLUMBING CALCULATIONS
TOTAL NUMBER OF SLEEPING UNITS WITH RESTROOMS: 22
TOTAL NUMBER OF RESTROOM FIXTURES NOT ACCESSIBLE
THRU OFFICES OR RESIDENT ROOMS:
TOTAL FLOOR AREA = 17,351 GSF
PLUMBING FIXTURES REQUIRED:
OCCUPANT LOAD CALCULATION:
2ND FLOOR:
A-3 OCCUPANCY: 1,481 NSF/15 NSF = 98.73 OCCUPANTS
98.73 OCCUPANTS / 2 = 49.365 OCCUPANT LOAD PER SEX
PER IBC TABLE 2902.1: ASSEMBLY OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
MALE WC FEMALE WC LAVS
1/125 1/65 1/200
A-3 (READING ROOMS) MINIMUM REQUIRED FIXTURES:
49.365 OCCUPANT LOAD/125 OCCUPANTS PER WC = .395 MALE
49.365 OCCUPANT LOAD/65 OCCUPANTS PER WC = .759 FEMALE
49.365 OCCUPANT LOAD/200 OCCUPANTS PER LAV =.247 MALE
49.365 OCCUPANT LOAD/200 OCCUPANTS PER LAV =.247 FEMALE
B OCCUPANCY: 650 GSF/150 GSF = 4.33 OCCUPANTS
4.33 OCCUPANTS / 2 = 2.165 OCCUPANT LOAD PER SEX
PER IBC TABLE 2902.1: BUSINESS OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
MALE WC FEMALE WC LAVS
1/25 FOR 1ST 50 1/25 FOR 1ST 50 1/40 FOR 1ST 80
AND 1 PER 50 FOR AND 1 PER 50 FOR AND 1 PER 80 FOR
THE REMAINDER THE REMAINDER THE REMAINDER
EXCEEDING 50 EXCEEDING 50 EXCEEDING 80
B MINIMUM REQUIRED FIXTURES:
2.165 OCCUPANT LOAD/25 OCCUPANTS PER WC = .087 MALE
2.165 OCCUPANT LOAD/25 OCCUPANTS PER WC = .087 FEMALE
2.165 OCCUPANT LOAD/40 OCCUPANTS PER LAV = .054 MALE
2.165 OCCUPANT LOAD/40 OCCUPANTS PER LAV = .054 FEMALE
I-1 OCCUPANCY: 10.081GSF/120 GSF = 84.008 OCCUPANTS
PER IBC TABLE 2902.1: INSTITUTIONAL OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
FEMALE WC LAVS
1/10 1/10
I-1 MINIMUM REQUIRED FIXTURES:
84.008 OCCUPANT LOAD/10 OCCUPANTS PER WC = 8.4 FEMALE
84.008 OCCUPANT LOAD/10 OCCUPANTS PER LAV = 8.4 FEMALE
U OCCUPANCY: 152 GSF/300 GSF = .507 OCCUPANTS
.867 OCCUPANTS / 2 = .507 OCCUPANT LOAD PER SEX
PER IBC TABLE 2902.1: STORAGE OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
MALE WC FEMALE WC LAVS
1/100 1/100 1/100
U MINIMUM REQUIRED FIXTURES:
.254 OCCUPANT LOAD/100 OCCUPANTS PER WC = .003 MALE
.254 OCCUPANT LOAD/100 OCCUPANTS PER WC = .003 FEMALE
.254 OCCUPANT LOAD/100 OCCUPANTS PER LAV = .003 MALE
.254 OCCUPANT LOAD/100 OCCUPANTS PER LAV = .003 FEMALE
NOTE:
PER 2902.1.1: TO DETERMINE OCCUPANT LOAD OF EACH SEX, THE TOTAL
OCCUPANT LOAD SHALL BE DIVIDED IN HALF. …. FOR CALCULATIONS
INVOLVING MULTIPLE OCCUPANCIES, SUCH FRACTIONAL NUMBERS FOR
EACH OCCUPANCY SHALL BE FIRST SUMMED AND THEN ROUNDED UP TO
THE NEXT WHOLE NUMBER
BUILDING 4 HAS WOMEN ONLY IN RESIDENT AREAS
THE MAXIMUM POPULATION OF RESIDENTS IS CURRENTLY
CONTRACTUALLY LIMITED TO LESS THAN 245 FOR THE ENTIRE FACILITY.
THE ACTUAL I-1 OCCUPANCY IS LIMITED BY THE NUMBER OF
RESIDENT ROOMS TO APPROXIMATELY 48 RESIDENTS
ON THIS FLOOR
TOTAL NUMBER OF MALE WC REQUIRED:
A-3 .395 B .087 I-1 0 U .003
TOTAL: .485 = 1 WC
TOTAL NUMBER OF FEMALE WC REQUIRED:
A-3 .759 B .087 I-1 8.400 U .003
TOTAL: 9.246 = 10 WC
TOTAL NUMBER OF MALE LAVS REQUIRED:
A-3 .247 B .054 I-1 0 U .003
TOTAL: .304 = 1 LAV
TOTAL NUMBER OF FEMALE LAVS REQUIRED:
A-3 .247 B .054 I-1 8.400 U .003
TOTAL: 8.704 = 9 LAVS
WC'S PROVIDED (PUBLIC)
WOMEN: 1
MEN: 1 + 1 URINAL
UNISEX: 1
WC'S PROVIDED (NON-PUBLIC))
WOMEN: 16
MEN: 0
UNISEX: 1
LAV'S PROVIDED (PUBLIC):
WOMEN: 1
MEN: 1
UNISEX: 1
LAV'S PROVIDED (NON-PUBLIC):
WOMEN: 16
MEN: 0
UNISEX: 1
SHOWER/TUB REQUIREMENTS I-1 OCCUPANCY:
TOTAL NUMBER OF POTENTIAL RESIDENTS =
I-1 OCCUPANTS 84.008
REQUIRED SHOWER UNITS = 1 SHOWER PER 8 RESIDENTS
85/8 = 10.625 = 11 SHOWERS REQUIRED
TOTAL NUMBER OF SHOWER UNITS PROVIDED = 14
PLUMBING FIXTURES REQUIRED:
OCCUPANT LOAD CALCULATION:
BASEMENT:
A-3 LIBRARY (READING ROOMS) OCCUPANCY:
810 NSF/50 GSF = 16.2 OCCUPANTS
16.2 OCCUPANTS / 2 = 8.1 OCCUPANT LOAD PER SEX
PER IBC TABLE 2902.1: ASSEMBLY OCCUPANCY (ASSUME KITCHENS,
RESTAURANT, BANQUET HALLS AND FOOD COURTS):
MINIMUM REQUIRED PLUMBING FIXTURES:
MALE WC FEMALE WC LAVS
1/125 1/65 1/200
A-3 (READING ROOMS) MINIMUM REQUIRED FIXTURES:
8.1 OCCUPANT LOAD/125 OCCUPANTS PER WC = .065 MALE
8.1 OCCUPANT LOAD/65 OCCUPANTS PER WC = .125 FEMALE
8.1 OCCUPANT LOAD/200 OCCUPANTS PER LAV =.040 MALE
8.1 OCCUPANT LOAD/200 OCCUPANTS PER LAV =.040 FEMALE
A-3 LIBRARY (STACK AREA) OCCUPANCY:
1,530 GSF/100 NSF = 15.3 OCCUPANTS
15.3 OCCUPANTS / 2 = 7.65 OCCUPANT LOAD PER SEX
A-3 LIBRARY(STACK AREA) MINIMUM REQUIRED FIXTURES:
7.65 OCCUPANT LOAD/125 OCCUPANTS PER WC = .061 MALE
7.65 OCCUPANT LOAD/65 OCCUPANTS PER WC = .118 FEMALE
7.65 OCCUPANT LOAD/200 OCCUPANTS PER LAV = .038 MALE
7.65 OCCUPANT LOAD/200 OCCUPANTS PER LAV = .038 FEMALE
B OCCUPANCY: 819 GSF/150 GSF = 5.46 OCCUPANTS
5.46 OCCUPANTS / 2 = 2.73 OCCUPANT LOAD PER SEX
PER IBC TABLE 2902.1: BUSINESS OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
MALE WC FEMALE WC LAVS
1/25 FOR 1ST 50 1/25 FOR 1ST 50 1/40 FOR 1ST 80
AND 1 PER 50 FOR AND 1 PER 50 FOR AND 1 PER 80 FOR
THE REMAINDER THE REMAINDER THE REMAINDER
EXCEEDING 50 EXCEEDING 50 EXCEEDING 80
B MINIMUM REQUIRED FIXTURES:
2.73 OCCUPANT LOAD/25 OCCUPANTS PER WC = .109 MALE
2.73 OCCUPANT LOAD/25 OCCUPANTS PER WC = .109 FEMALE
2.73 OCCUPANT LOAD/40 OCCUPANTS PER LAV = .068 MALE
2.73 OCCUPANT LOAD/40 OCCUPANTS PER LAV = .068 FEMALE
B OCCUPANCY SHOP/VOCATIONAL AREAS):
3,379 GSF/50 GSF = 67.58 OCCUPANTS
67.58 OCCUPANTS / 2 = 33.79 OCCUPANT LOAD PER SEX
PER IBC TABLE 2902.1: BUSINESS OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
MALE WC FEMALE WC LAVS
1/25 FOR 1ST 50 1/25 FOR 1ST 50 1/40 FOR 1ST 80
AND 1 PER 50 FOR AND 1 PER 50 FOR AND 1 PER 80 FOR
THE REMAINDER THE REMAINDER THE REMAINDER
EXCEEDING 50 EXCEEDING 50 EXCEEDING 80
B MINIMUM REQUIRED FIXTURES:
33.79 OCCUPANT LOAD/25 OCCUPANTS PER WC = 1.352 MALE
33.79 OCCUPANT LOAD/25 OCCUPANTS PER WC = 1.352 FEMALE
33.79 OCCUPANT LOAD/40 OCCUPANTS PER LAV = .845 MALE
33.79 OCCUPANT LOAD/40 OCCUPANTS PER LAV = .845 FEMALE
S-1 OCCUPANCY: 1,641 GSF/300 GSF = 5.47 OCCUPANTS
U OCCUPANCY: 1,650 GSF/300 GSF = 5.50 OCCUPANTS
(5.47 OCCUPANTS + 5.50 OCCUPANTS) / 2 = 5.485 OCCUPANT LOAD PER SEX
PER IBC TABLE 2902.1: STORAGE OCCUPANCY:
MINIMUM REQUIRED PLUMBING FIXTURES:
MALE WC FEMALE WC LAVS
1/100 1/100 1/100
S-2/U MINIMUM REQUIRED FIXTURES:
5.485 OCCUPANT LOAD/100 OCCUPANTS PER WC = .055 MALE
5.485 OCCUPANT LOAD/100 OCCUPANTS PER WC = .055 FEMALE
5.485 OCCUPANT LOAD/100 OCCUPANTS PER LAV = .055 MALE
5.485 OCCUPANT LOAD/100 OCCUPANTS PER LAV = .055 FEMALE
NOTE:
PER 2902.1.1: TO DETERMINE OCCUPANT LOAD OF EACH SEX, THE TOTAL
OCCUPANT LOAD SHALL BE DIVIDED IN HALF. …. FOR CALCULATIONS
INVOLVING MULTIPLE OCCUPANCIES, SUCH FRACTIONAL NUMBERS FOR
EACH OCCUPANCY SHALL BE FIRST SUMMED AND THEN ROUNDED UP TO
THE NEXT WHOLE NUMBER
TOTAL NUMBER OF MALE WC REQUIRED:
A-3 (LIBRARY READING RMS) .065
A-3 (LIBRARY STACK AREA) .061
B .109
B (SHOP/VOCATIONAL) 1.352
S-1/U .055
TOTAL: 1.642 = 2 WC
TOTAL NUMBER OF FEMALE WC REQUIRED:
A-3 (LIBRARY READING RMS) .125
A-3 (LIBRARY STACK AREA) .118
B .109
B (SHOP/VOCATIONAL) 1.352
S-1/U .055
TOTAL: 1.759 = 2 WC
TOTAL NUMBER OF MALE LAVS REQUIRED:
A-3 (LIBRARY READING RMS) .040
A-3 (LIBRARY STACK AREA) .038
B .068
B (SHOP/VOCATIONAL) .845
S-1/U .055
TOTAL: 1.046 = 2 LAV
TOTAL NUMBER OF FEMALE LAVS REQUIRED:
A-3 (LIBRARY READING RMS) .040
A-3 (LIBRARY STACK AREA) .038
B .068
B (SHOP/VOCATIONAL) .845
S-1/U .055
TOTAL: 1.046 = 2 LAV
WC'S PROVIDED
WOMEN: 3
MEN: 1 + 1 URINAL
UNISEX: 2
LAV'S PROVIDED
WOMEN: 1
MEN: 1
UNISEX" 2
THE MAXIMUM POPULATION OF RESIDENTS IS CURRENTLY
CONTRACTUALLY LIMITED TO LESS THAN 245 FOR THE ENTIRE FACILITY
TOTAL FLOOR AREA = 17,351 GSF
CONSULTANTS
PROJECT NO: #Project Code
MODEL FILE:
Fort Lyon Bldg 4-life safety.pln
DRAWN BY: TAD
DATE: 20 MARCH 2023
G-004
A
B
C
D
E
/U se rs /ta du ke
/D oc um en ts /A rc hi ca d
Fi le s/ Fo rt Ly on B ld g
4-lif e sa fe ty
.p ln
BASEMENT CODE STUDY
PLAN
Fort Lyon Life Safety Corrections -
Building 4
Building 4 Fort Lyon, 81054
T.A. DUKE & ASSOCIATES, Inc.
4220 Brigadoon Lane
Colorado Springs, CO 80906 719 648 7722 taduke@earthlink.net
Structural Engineering:
HCDA Engineering, Inc.
9 South Weber Colorado Springs, CO 80903
719 633 7784
MEP Engineering:
McShea Consulting LLC
4445 Northpark Dr., Suite 200 Colorado Springs, CO 80907
719 358 8208
PROJECT NUMBER: 2021-035M21/HB 1408
3/31/23 ISSUED FOR CODE REVIEW
4/13/23 ISSUED FOR STATE REVIEW
4/21/23 CODE COMMENT REVISIONS
6/13/23 ISSUED FOR STATE REVIEW
9/21/2023
7/19/23
ISSUED FOR CODE
CONSULTANT REVIEW
8/23/23
ISSUED FOR CODE
CONSULTANT REVIEW
9/21/23
ISSUED FOR BIDS
ELEVATORELEVATOR
D-008C
D-008A D-008B
D-007 D-006
D-005
D-002D-003
D-004
D-001
D-020D-021
D-019B
D-019
D-019C
D-019E
D-019D
D-020A
D-008E
D-000-SS D-013
D-016A
D-016 D-000-NS
D-018E
D-017 D-018
D-019G
D-021AD-022
D-001A
D-023
D-008F
D-008
D-CH-001 D-CH-002
D-019F
D-018D
D-018A
D-000SH
D-000CH
D-018B
D-010
D-009
D-012
D-013A
D-014 D-015A D-015
D-019A
D-008D
E G
R E
S S
E G
R E
S S
EGRESSEGRESSEGRESS
D
IS
TA
N
C E
O F
C O
M M
O N
P
AT
H
4"
D
IS
TA
N
C E
O F
C O
M M
O N
P
AT
H
'-1
1/
2"
D
IS
TA
NC
E
OF
CO
M
M
ON
PA
TH
27'-8" = DISTANCE OF
COMMON PATH
33'-5" = DISTANCE OF
COMMON PATH
RESTRM
018A
A: 58 sq ft
STOR
018B
A: 41 sq ft
ARTS AND CRAFTS
A: 1,352 sq ft
STOR
018D
A: 126 sq ft
CHASE
018E
A: 23 sq ft
STOR
A: 204 sq ft
STORAGE
A: 170 sq ft
ARTS AND CRAFTS
019A
A: 1,402 sq ft
UTILITY
019B
A: 94 sq ft
STORAGE
019E
A: 70 sq ft
MECHANICAL
019G
A: 568 sq ft
ARTS AND CRAFTS
A: 438 sq ft
ARTS AND CRAFTS
A: 266 sq ft
STORAGE
A: 169 sq ft
UTILITY
A: 155 sq ft
STORAGE
016A
A: 91 sq ft
RESTRM
015A
A: 149 sq ft
ARTS AND CRAFTS
A: 218 sq ft
RESTRM
A: 150 sq ft
MACHINE RM
A: 143 sq ft
STORAGE
A: 277 sq ft
BOILER RM
A: 710 sq ft
STORAGE
A: 70 sq ft
LOBBY
A: 335 sq ft
MACHINE RM
A: 141 sq ft
RESTRM
A: 75 sq ft
UTILITY
A: 88 sq ft
LIBRARY
A: 1,533 sq ft
WORKRM
008A
A: 688 sq ft
STORAGE
008B
A: 132 sq ft
LIBRARY
008D
A: 203 sq ft
COMPUTER LAB
008C
A: 154 sq ft
PEER STATIONS
008E
A: 721 sq ft
OFFICE
A: 131 sq ft
ARTS AND CRAFTS
A: 611 sq ft
STAIR
000-NS
A: 207 sq ft
STAIR
000-SS
A: 208 sq ft
CENTER HALL
000-CH
A: 2,091 sq ft
SOUTH HALL
000-SH
A: 776 sq ft
CHASE
019D
A: 14 sq ft
STOR
013A
A: 74 sq ft
STORAGE
A: 158 sq ft
STORAGE
A: 316 sq ft
N
SCALE: 1/8" = 1'-0"A1 BASEMENT CODE STUDY PLAN
0 4' 8' 16'
GROUP S-2 OCCUPANCY - LOW
HAZARD STORAGE
GROUP B OCCUPANCY - BUSINESS
GROUP I-1 OCCUPANCY - INSTITUTIONAL;
CONDITION 1
GROUP A-3 OCCUPANCY - ASSEMBLY
UNASSIGNED OCCUPANCY - MECHANICAL/
ELECTRICAL/UTILITY
SHOWN AS (1) HR RATED CONSTRUCTION
ON PREVIOUS CONSTRUCTION
DOCUMENTS) - PENETRATIONS HAVE NOT
BEEN VERIFIED FOR (1) HOUR COMPLIANCE
6" CLAY TILE CONSTRUCTION WITH FINSH
ON ONE SIDE (UP TO 1 HOUR FIRE RATING) -
PENETRATIONS HAVE NOT BEEN VERIFIED
FOR (1) HOUR COMPLIANCE
6" CLAY TILE CONSTRUCTION WITH FINSH
BOTH SIDES (UP TO 2 HOUR FIRE RATING) -
PENETRATIONS HAVE NOT BEEN VERIFIED
FOR (2) HOUR COMPLIANCE
8" DOUBLE WYTHE BRICK CONSTRUCTION
WITH FINSH ON ONE SIDE (UP TO 6 HOUR
FIRE RATING) - PENETRATIONS HAVE NOT
BEEN VERIFIED FOR (1) HOUR COMPLIANCE
12 1/2" CLAY TILE CONSTRUCTION WITH
BRICK AT EXTERIOR AND PLASTER AT
INTERIOR (UP TO 6 HOUR FIRE RATING) -
PENETRATIONS HAVE NOT BEEN VERIFIED
FOR (1) HOUR COMPLIANCE
GROUP A-1 OCCUPANCY - ASSEMBLY
(1) HOUR WALL CONSTRUCTION (NEW WALL
CONSTRUCTION)
2 x 4 WOOD STUD AT 16" OC WITH 5/8"
PLASTER ON METAL LATHE EACH SIDE- (1)
HOUR FIRE RATING - PENETRATIONS HAVE
NOT BEEN VERIFIED FOR (1) HOUR
COMPLIANCE
4" CLAY TILE CONSTRUCTION WITH FINSH
BOTH SIDES (UP TO 1 HOUR 34 MINUTES
FIRE RATING) - PENETRATIONS HAVE NOT
BEEN VERIFIED FOR (1) HOUR COMPLIANCE
GROUP S-1 OCCUPANCY - MODERATE
STORAGE
NUMBER OF SLEEPING UNITS: 0
NUMBER OF ADA SLEEPING UNITS: 0
PROJECT NAME: FORT LYON LIFE SAFETY IMPROVEMENTS -
BUILDING 4
STATE PROJECT
NUMBER: 2021-035M21/HB 1408
LOCATION: FORT LYON, COLORADO
FLOOR AREA: BASEMENT - 17,415 GSF
CONSTRUCTION TYPE: NON CONFORMING TYPE IIB (SPRINKLERED)
NOTE: ALL NEW INTERIOR CONSTRUCTION WILL
MEET OR EXCEED FIRE RESISTIVE MATERIALS
REQUIRED BY TYPE IIB CONSTRUCTION
ALLOWABLE HEIGHT: A-3 OCCUPANCY: 75'
B OCCUPANCY: 75'
S-2 OCCUPANCY: 75'
ACTUAL HEIGHT: 49'-9" (AT EAST ELEVATION - TO TOP OF ROOF)
ALLOWABLE STORIES: A-3 OCCUPANCY: 3
(ABOVE GRADE) B OCCUPANCY: 4
S-2 OCCUPANCY: 4
ACTUAL STORIES: 2 STORIES ABOVE GRADE ( PLUS ATTIC);
1 STORY BELOW GRADE
ALLOWABLE FLOOR AREA
PER TABLE 506.2: A-3 OCCUPANCY: 28,500 SF
B OCCUPANCY: 69,000 SF
S-2 OCCUPANCY: 78,000 SF
FRONTAGE INCREASE FACTOR: 50-75% OF BUILDING PERIMETER AND
30' OR GREATER OPEN SPACE = .50
ALLOWABLE AREA THIS STORY:
A-3 OCCUPANCY: Aa = 28,500 SF + (9,500 SF X .5) = 33,250 SF B OCCUPANCY: Aa = 69,000 SF + (23,000 SF X .5) = 80,500 SF S-2 OCCUPANCY: Aa = 78,000 SF + (26,000 SF x .5) = 91,000 SF
MIXED OCCUPANCY FACTOR: 6,894 SF/33,250 SF = .21
131 SF/80,500 SF = .00
1,641 SF/91,000 SF = .02
TOTAL = .23 = LESS THAN 1
ACTUAL BUILDING AREA: 52,117 GSF
OCCUPANCY CALCS: BASEMENT:
A-3 LIBRARY
READING RMS: 810 SF/50 = 16.2
A-3 LIBRARY
STACK AREA: 1,533 SF/100 = 15.33
B OCCUPANCY: 819 SF/150 = 5.46
B OCCUPANCY
SHOP/VOCATIONAL AREA: 3,379 SF/50 = 67.58
S-1 OCCUPANCY: 1,641 SF/300 = 5.47
MECH/ELECT RM.
OCCUPANCY: 1,650 SF/300 = 5.50
TOTAL FLOOR OCCUPANCY: 115.54 =
EXITS :
(EXITING WIDTH) 116 * .15 = 17.40"
REQUIRED EGRESS CORRIDOR WIDTH: 44"
ACTUAL EGRESS CORRIDOR WIDTH: 9'-0"
(STAIR WIDTH) 116 * .20 = 23.2"
(2) STAIRS PROVIDED : (2) @ 53" WIDTH EACH
GROUP B OCCUPANCY - ADULT VOCATIONAL
AND SHOP AREAS
LEGEND
OCCUPANCY CALCULATIONS
LEVEL 2 ALTERATIONS: Level 2 alterations include the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment, and shall apply where the work area is equal to or less than 50 percent of the building area.
801.3 System Installations
Requirements related to work area are not applicable where the Level 2 alterations are limited solely to one or more of the following:
1 Mechanical systems, electrical systems, fire protection systems and abatement of hazardous materials.
| 2 | Windows, hardware, operating controls, electrical outlets and signs. |
| 3 | Alterations undertaken for the primary purpose of increasing the |
accessibility of a facility.
1203.6 Stairway Enclosure
In buildings of three stories or less, exit enclosure construction shall limit the spread of smoke by the use of tight-fitting doors and solid elements. Such elements are not required to have a fire-resistance rating.
1203.7 One-Hour Fire-Resistant Assemblies
Where 1-hour fire-resistance-rated construction is required by these provisions, it need not be provided, regardless of construction or occupancy, where the existing wall and ceiling finish is wood or metal lath and plaster.
IEBC COMMENTS
SHOWN AS (2) HR RATED CONSTRUCTION
ON PREVIOUS CONSTRUCTION
DOCUMENTS) - PENETRATIONS HAVE NOT
BEEN VERIFIED FOR (2) HOUR COMPLIANCE
1. ROOM 018 DOES NOT HAVE THE REQUIRED ADA CLEARANCES
AT THE ENTRY DOOR. THESE ROOMS WILL BE MODIFIED EXTENSIVELY,
AND ADA REQUIREMENTS WILL BE INCORPORATED DURING THE
TRAUMA INFORMED DESIGN PHASE. FOR THIS REASON, THE ENTRY
DOOR HAS NOT BEEN REVISED AT THESE LOCATIONS.
NOTES
CONSULTANTS
PROJECT NO: #Project Code
MODEL FILE:
Fort Lyon Bldg 4-life safety.pln
DRAWN BY: TAD
DATE: 20 MARCH 2023
G-005
A
B
C
D
E
/U se rs /ta du ke
/D oc um en ts /A rc hi ca d
Fi le s/ Fo rt Ly on B ld g
4-lif e sa fe ty
.p ln
1ST FLOOR CODE STUDY
PLAN
Fort Lyon Life Safety Corrections -
Building 4
Building 4 Fort Lyon, 81054
T.A. DUKE & ASSOCIATES, Inc.
4220 Brigadoon Lane
Colorado Springs, CO 80906 719 648 7722 taduke@earthlink.net
Structural Engineering:
HCDA Engineering, Inc.
9 South Weber Colorado Springs, CO 80903
719 633 7784
MEP Engineering:
McShea Consulting LLC
4445 Northpark Dr., Suite 200 Colorado Springs, CO 80907
719 358 8208
PROJECT NUMBER: 2021-035M21/HB 1408
3/31/23 ISSUED FOR CODE REVIEW
4/13/23 ISSUED FOR STATE REVIEW
4/21/23 CODE COMMENT REVISIONS
6/13/23 ISSUED FOR STATE REVIEW
9/21/2023
7/19/23
ISSUED FOR CODE
CONSULTANT REVIEW
8/23/23
ISSUED FOR CODE
CONSULTANT REVIEW
9/21/23
ISSUED FOR BIDS
DOWN
DOWN
DOWN
DOWN
X
X
XXX
DOWN
D-124 D-125
D-125A
D-124C
D-124A
D-121
D-SH-002
D-118
D-120
D-116
D-115
D-113
D-114
D-108 D-107
D-109D-110
D-109A
D-110A
D-112
D-119
D-119B
D-119A
D-121A D-121C
D-125C
D-100-SS
D-103A
D-106A
D-103B
D-101A
D-128A
D-128 D-128A
D-129 D-130 D-131
D-100-CH1
D-133
D-138
D-140A
D-139
D-140 D-100-NS
D-157
D-159A
D-159AD-159
D-161A
D-160D-161 D-158
D-152
D-147
D-148
D-149
D-150
D-120
D-146
D-145B
D-152A
D-153
D-NH-002
D-143A
D-143B
D-143B
D-141A
D-142B
D-142 D-143
D-100-CC
D-155
D-100-CC-A
D-117
D-100-CW1
D-100A-NSD-100A-SS
D-151
D-SH-001
D-127 D-130A
D-137
D-145A
D-145B
D-145C
D-122A
D-122
D-122B
D-122C
D-121B
D-111
D-106
D-105
D-103C D-103
D-156
D-154
D-145
D-142A
D-136
D-132
D-132A
D-NH-001
D-126D-123
D-123A D-126A
D-101
D-102
D-104
D-144D-141
NOTE: THE DISTANCE FROM THE EXIT TO THE END
OF THE HALL EXCEEDS 50' . THIS CONDITION DOES
NOT MEET CURRENT CODE REQUIREMENTS. IT IS
ANTICIPATED THAT THIS WILL BE ADDRESSED
DURING THE TRAUMA INFORMED DESIGN PROJECT;
DURING PAST RENOVATIONS, THE DEAD END
CORRIDOR HAS BEEN ADDRESSED WITH A RATED
CROSS DOOR/WALL, LIMITING THE DISTANCE TO UNDER 50'.
NOTE: THE DISTANCE FROM THE EXIT TO THE END
OF THE HALL EXCEEDS 50' . THIS CONDITION DOES
NOT MEET CURRENT CODE REQUIREMENTS. IT IS
ANTICIPATED THAT THIS WILL BE ADDRESSED
DURING THE TRAUMA INFORMED DESIGN PROJECT;
DURING PAST RENOVATIONS, THE DEAD END
CORRIDOR HAS BEEN ADDRESSED WITH A RATED
CROSS DOOR/WALL, LIMITING THE DISTANCE TO UNDER 50'.
NOTE: THE DISTANCE FROM THE EXIT TO THE END
OF THE HALL EXCEEDS 50' . THIS CONDITION DOES
NOT MEET CURRENT CODE REQUIREMENTS. IT IS
ANTICIPATED THAT THIS WILL BE ADDRESSED
DURING THE TRAUMA INFORMED DESIGN PROJECT;
DURING PAST RENOVATIONS, THE DEAD END
CORRIDOR HAS BEEN ADDRESSED WITH A RATED
CROSS DOOR/WALL, LIMITING THE DISTANCE TO UNDER 50'.
NOTE: THE DISTANCE FROM THE EXIT TO THE END
OF THE HALL EXCEEDS 50' . THIS CONDITION DOES
NOT MEET CURRENT CODE REQUIREMENTS. IT IS
ANTICIPATED THAT THIS WILL BE ADDRESSED
DURING THE TRAUMA INFORMED DESIGN PROJECT;
DURING PAST RENOVATIONS, THE DEAD END
CORRIDOR HAS BEEN ADDRESSED WITH A RATED
CROSS DOOR/WALL, LIMITING THE DISTANCE TO UNDER 50'.
E G
R E
S S
EGRESSEGRESS
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
27'-6" =
DISTANCE OF
COMMON PATH
'-2
D
IS
TA
N C
E O
F C
O M
M O
N P
AT
H
'-1
0"
D
IS
TA
N
C E
O F
C O
M M
O N
P
AT
H
STOR
A: 117 sq ft
ADA BEDRM
A: 216 sq ft
UTILITY
A: 47 sq ft
STOR
A: 60 sq ft
STOR
A: 39 sq ft
DAY RM
A: 513 sq ft
BEDRM
A: 230 sq ft
RESTRM
A: 71 sq ft
BEDRM
A: 236 sq ft
HALL
100-CW
A: 99 sq ft
DAY RM
A: 515 sq ft
RESTRM
A: 287 sq ft
ADA BEDRM
123A
A: 165 sq ft
RESTRM
124A
A: 75 sq ft
BEDRM
A: 261 sq ft BEDRM
A: 261 sq ft
RESTRM
125A
A: 75 sq ft
ADA BEDRM
126A
A: 171 sq ft OFFICE
A: 235 sq ft
ADA RESTRM
A: 74 sq ft
ADA RESTRM
A: 79 sq ft
STAIR
100-SS
A: 191 sq ft
STAIR
100-NS
A: 181 sq ft
UTILITY
A: 96 sq ft
RESTRM
A: 71 sq ft
RESTRM
A: 115 sq ft
RESTRM
A: 86 sq ft
RESTRM
A: 110 sq ft
RESTRM
143A
A: 83 sq ft
ADA RESTRM
145A
A: 86 sq ft
RESTRM
A: 84 sq ft
RESTRM
152A
A: 65 sq ft
RESTRM
A: 72 sq ft
RESTRM
A: 78 sq ft
RESTRM
A: 39 sq ft
RESTRM
140A
A: 68 sq ft
RESTRM
142A
A: 73 sq ft
BEDRM
A: 117 sq ft
STOR
A: 27 sq ft
CHASE
103B
A: 25 sq ft
STORAGE
103A
A: 37 sq ft
DAY ROOM
A: 827 sq ft
CHASE
A: 31 sq ft
STOR
106A
A: 11 sq ftBEDRM
A: 207 sq ft
BEDRM
A: 266 sq ft
BEDRM
A: 268 sq ft
BEDRM
A: 227 sq ft
ADA BEDRM
A: 223 sq ft
CHASE
145B
A: 56 sq ft
STOR
A: 13 sq ft
STOR
151A
A: 23 sq ft
BEDRM
A: 211 sq ft
CHASE
A: 8 sq ft
BEDRM
A: 183 sq ft
UTILITY
A: 68 sq ft
STOR
156A
A: 16 sq ft
CHASE
A: 17 sq ft
HALL
100-NH
A: 964 sq ft
CHASE
159A
A: 7 sq ft
HALL
100-CC
A: 1,491 sq ft
OFFICE
A: 96 sq ft
LAUNDRY
A: 86 sq ft
HALL
100-CE
A: 261 sq ft
BEDRM
A: 235 sq ft
CHASE
109A
A: 15 sq ft
BEDRM
110A
A: 154 sq ft
CHASE
A: 17 sq ft
STOR
A: 17 sq ft
UTILITY
A: 49 sq ft
STOR
A: 65 sq ft
STOR
A: 52 sq ft
STOR
A: 69 sq ft
STOR
117A
A: 20 sq ft
BEDRM
A: 201 sq ft
CHASE
119A
A: 15 sq ft
BEDRM
A: 172 sq ft
RESTRM
121A
A: 66 sq ft
CHASE
121B
A: 14 sq ft
BEDRM
A: 207 sq ft
CHASE
122B
A: 22 sq ft
HALL
100-SH
A: 974 sq ft
CHASE
122A
A: 40 sq ft
BEDRM
A: 184 sq ft
CHASE
128A
A: 28 sq ft
BEDRM
A: 152 sq ft
BREAK RM
A: 53 sq ft
OFFICE
A: 171 sq ft
CHASE
A: 29 sq ft
BEDRM
A: 190 sq ft
BEDRM
A: 242 sq ft
CHASE
143B
A: 9 sq ft
VESTIBULE
A: 68 sq ft
CHASE
122C
A: 15 sq ft
CHASE
141A
A: 8 sq ft
VESTIBULE
127A
A: 53 sq ft
STOR
A: 8 sq ft
CHASE
161A
A: 17 sq ft
CHASE
103C
A: 14 sq ft
STOR
130A
A: 13 sq ft
N
SCALE: 1/8" = 1'-0"A1 1st FLOOR CODE STUDY PLAN 0 4' 8' 16'
PROJECT NAME: FORT LYON LIFE SAFETY IMPROVEMENTS -
BUILDING 4
STATE PROJECT
NUMBER: 2021-035M21/HB 1408
LOCATION: FORT LYON, COLORADO
FLOOR AREA: 1ST FLOOR - 17,351 GSF
CONSTRUCTION TYPE: NON CONFORMING TYPE IIB (SPRINKLERED)
NOTE: ALL NEW INTERIOR CONSTRUCTION WILL
MEET OR EXCEED FIRE RESISTIVE MATERIALS
REQUIRED BY TYPE IIB CONSTRUCTION
ALLOWABLE HEIGHT: A-3 OCCUPANCY: 75'
B OCCUPANCY: 75'
I-1 OCCUPANCY: 75'
S-2 OCCUPANCY: 75'
ACTUAL HEIGHT: 46' (AT WEST ELEVATION - TO TOP OF ROOF)
ALLOWABLE STORIES: A-3 OCCUPANCY: 3
B OCCUPANCY: 4
I-1 OCCUPANCY: 3
S-2 OCCUPANCY: 4
ACTUAL STORIES: 4 STORIES ABOVE GRADE ( PLUS ATTIC);
1 STORY BELOW GRADE
ALLOWABLE FLOOR AREA
PER TABLE 506.2: A-3 OCCUPANCY: 28,500 SF
B OCCUPANCY: 69,000 SF
I-1 OCCUPANCY: 30,000 SF
S-2 OCCUPANCY: 78,000 SF
FRONTAGE INCREASE FACTOR: 50-75% OF BUILDING PERIMETER AND
30' OR GREATER OPEN SPACE = .50
ALLOWABLE AREA THIS STORY:
A-3 OCCUPANCY: Aa = 28,500 SF + (9,500 SF X .5) = 33,250 SF B OCCUPANCY: Aa = 69,000…
This is the start of the file's text. The full file is on GovTribe.