Appendix G - Government Test Checklist.xlsx
XLSX spreadsheet 50 KB Posted
- Attached to
- Live Training, Ranges, and Combat Training Centers (LTRaC) Multiple Award Contract (MAC) 1
- Solicitation number
- W900KK-25-R-0001
About this file
This document is a Government Test Checklist for the Basic Army Target Lifter (BATL) and associated items. It outlines the testing requirements for the First Article Test (FAT) and Acceptance Testing (AT) of various target mechanisms, including Stationary Infantry Targets (SITs), Stationary Armor Targets (SATs), Moving Infantry Targets (MITs), and Moving Armor Targets (MATs). The checklist covers specific requirements such as mechanism adjustability, lifting arm specifications, track and stabilization, and general performance parameters. It also addresses requirements for portable mechanisms, muzzle flash simulators, and non-automated devices like lifter shields. The checklist specifies the verification methods, which include inspection, demonstration, and analysis. Additionally, it outlines general testing requirements related to range startup/shutdown, Battle Effects Simulators, technical manuals, and new equipment training.
This checklist is referenced in the pre-solicitation notice for the Live Training, Ranges, and Combat Training Centers (LTRaC) Multiple Award Contract (MAC) 1, which is a U.S. Army Contracting Command-Orlando (ACC-ORL) requirement to provide and install live-fire training systems using the BATL Technical Data Package (TDP). The LTRaC MAC 1 contract will support military ranges worldwide, with equipment used for both day and night training under all weather conditions.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contractor Guide
| BASIC ARMY TARGET LIFTER (BATL) & ASSOCIATED ITEMS TESTING CHECKLIST (V.1) |
| NOTES: |
1. All requirements for FAT must pass prior to the first delivery of establishment or re-establishment of a production line.
2. All FAT items are subject to reverification at AT
3. All requirements for AT must be pass prior to acceptance of the fielded equipment under the DO
4. *- Data sheets/Spec sheets can be used as validation material that will provide enough data to address the requirement.
5. The contractor is responsible for meeting all applicable local, state, and federal laws and regulations.
6. Mechanisms, spare parts and all applicable documents required per the delivery order (DO) will be inventoried and inspected at AT
| Government Testing Types | ||
| SOW 3.4.1 | First Article Test (FAT) | The FAT units are to be produced from the production line utilizing the contractor’s established production line instructions and QA check points, and not individually fabricated samples. The contractor is to produce five SITs, two SATs, one MIT, and one MAT in support of the FAT requirements. |
| SOW 3.4.1 | First Article Test | FAT is for the first production of each target type. All FAT events nust pass prior to the resumption of full-rate production. |
| SOW 3.4.2 | Physical Configuration Audit (PCA) | Performed at FAT. The PCA inspects the system hardware and technical documentation for completeness and accuracy. The PCA verifies that the physical configuration of the system(s) and components correspond to the build-to BATL product baseline documentation, and includes inspection of inventory/equipment lists, documentation, spares, and manuals. |
| SOW 3.4.5 | Acceptance Testing (AT) | The AT validates that the complete system works properly and can support live fire training missions at the range. |
| Government Verification Methods | |
| Inspection | Examination of product(s) or system(s) using one or more of the five senses. May include simple physical manipulation and measurement. |
| Demonstration | Manipulation of the product(s) or system(s) as it is intended to be used |
| Analysis | Verification of product(s) or system(s) based on confirmed test restults |
| 3.6 | Control System | |
| All BATL mechanisms function utilizing TRACR II |
| PS 3.3.6.1 | Cross-Ties | Cross-ties are constructed from new material as specified in part 3 of the in the American Railway Engineering and Maintenance-of-Way Association (AREMA) |
| PS 3.3.6.1 | Cross-Ties | The cross-ties are a minimum size of Grade 6 (dimensions of 6” height by 8” width). The cross-tie standard Grade dimension remains consistent along the entire length of the cross-tie holding a tolerance of plus 1” and minus ¼”. |
| PS 3.3.6.1 | Cross-Ties | Contractor provided cross-ties are a length no less than 8’ |
| a | Cross-Ties | If ballast is required to meet the stabilty requirement, the grading size is a two inch diamter or less |
TM Testing Requirements
| Ref # | Requirement Description | Acceptance Event(s) | Verification Method | |
| Stationary Target Mechanisms | ||||
| Stationarty Infanty Target (SIT) | ||||
| PS 3.1.3 | SIT Mechanism Adjustability | |||
| SITs that are required to be bolted into emplacements include a system that allows for relocation of the mechanism 8”-12” backwards from its bolted location | FAT/AT | Demonstration | ||
| PS 3.1.3 | SIT Mechanism Adjustability | |||
| The system accomplishes the relocation without unbolting the mechanism from the emplacement floor in less than 10 seconds by no more than one (1) range person. | FAT | Demonstration | ||
| Stationary Armor Target (SAT) | ||||
| PS 3.1.4 | SAT Lifting Arms | SAT arms include a minimum of 2 U-bot assemblies for short arms or 4 U-bolt assemblies for long arms | FAT/AT | Inspection |
| PS 3.1.4 | SAT Lifting Arms | Short arms measure at 80" with 72" exposed and/or long arms measure at 44" with 36" exposed | FAT | Inspection |
| PS 3.1.4 | SAT Lifting Arms | The U-bolt assemblies can be relocated throughout the length of the arms by the user | FAT/AT | Demonstration |
| Moving Target Mechanisms | ||||
| PS 3.1.5 | Moving Target Mechanisms Track | MIT/MAT track are per the Gov't TDP | FAT | Inspection |
| PS 3.1.5 | Moving Target Mechanisms Track | All Moving TM tracks are connected to the provided ground rod in the emplacement | AT | Inspection |
| PS 3.2.6 | Track Bed | Track stanchions line up with existing or replaced railroad cross-ties | AT | Inspection |
| General Requirement | Stacking | Track is stable with no visual deficiencies | AT | Inspection |
| General Requirement | Stakes | Track stakes do not raise from the ground, concrete, or cross-ties during consistent run of mechanism | AT | Inspection |
| Moving Infantry Target (MIT) | ||||
| General Requirement | MIT Silhouette Orientation | The MIT turntable functions as required | FAT/AT | Demonstration |
| Moving Armor Target (MAT) | ||||
| General Requirement | MAT Stop Safety | MAT safety stop/power cutoff is in working condition | FAT/AT | Demonstration |
| General Requirement | MAT Warning Indicator | Move warning indicator (audible) signal is evident during impending movement of the Moving TM. | FAT/AT | Demonstration |
| Special Target Mechanism Considerations | ||||
| Portable Mechanisms | ||||
| PS 3.1.6 | Portable SIT and SAT | Portable stationary TMs and all their components are mounted within the 3-D area of the self-contained unit (SCU). The target arm (when target is in the up position only), the target itself, the SAT target arms, and the radio antenna are the only components that have portions of each that extend beyond the 3-D area | FAT | Inspection |
| PS 3.1.6 | Portable SIT and SAT | Each portable TM and component required for operation have a designated mounting location within the SCU | FAT | Inspection |
| PS 3.1.6 | Portable SIT and SAT | The SCU has a mounting location to hold the SAT arms after they have been removed. | FAT | Inspection |
| PS 3.1.6 | Portable SIT and SAT | Each radio fits the designated mounting location for a radio within the SCU. | FAT | Inspection |
| PS 3.1.6 | Portable SIT and SAT | For the TM and the components, the mounting provisions allow each to be removed from the SCU in less than five minutes. | FAT | Demonstration |
| PS 3.1.6 | Portable SIT and SAT | The design of the SCU includes at least two handles or grasp areas for SIT and four for the SAT | FAT | Inspection |
| PS 3.1.6 | Portable SIT and SAT | The SCU is made out of stainless steel or aluminum | FAT* | Analysis |
| PS 3.1.6 | Portable SIT and SAT | Portable device weights meet Table 1 requirements | FAT | Demonstration |
| PS 3.1.6 | Portable SIT and SAT | The SCU stabilizes the TM and its associated components to allow them to meet their operational requirements when placed on unimproved (3% or less slope) ground and in winds up to 35 mph. | FAT | Demonstration |
| Muzzle Flash Simulator (MFS) | ||||
| General Requirement | The MFS operates in both a single shot and a multiple shot mode | FAT/AT | Demonstration |
| Non Automated Targetry Devices | ||||
| Lifter shields (LS) | ||||
| PS 3.3.3 | Lifter Shields | The LS is designed to be free standing. | FAT | Demonstration |
| PS 3.3.3 | Lifter Shields | The LS is made from ballistic grade materials sufficient to withstand all rounds up to 7.62mm EPR shot at distances ranging from 25 meters and beyond | FAT* | Analysis |
| PS 3.3.3 | Lifter Shields | The LS is made from ballistic grade materials sufficient to withstand .50 cal ball ammunition (M2 Heavy Barrel Machine Gun) shot at a minimum distance of 0.25 miles | FAT* | Analysis |
| PS 3.3.3 | Lifter Shields | The LS is constructed such that front face or plate facing the shooter is angled. The front face plate angle shall dissipate energy and prevent ricochets, rounds, and splatter from bouncing back in the direction of the shooter | FAT | Inspection |
| PS 3.3.3 | Lifter Shields | No special tools are required for assembly of the LS. The LS has lift eyes and/or handles. The handles/ lift eyes are protected from damage due to normal firing | FAT | Inspection |
| PS 3.3.3 | Lifter Shields | The LS protects the TM and associated equipment from rounds shot from 20 degrees or less to either side | FAT* | Analysis |
| PS 3.3.3 | Lifter Shields | The LS protects the TM from rounds shot from a minimum of 15 degrees above | FAT* | Analysis |
| PS 3.3.3 | Lifter Shields | LS material withstands 500 rounds of 7.62mm and 1000 rounds of 5.56mm shot into a 3” square area with no evidence of penetration such that a subsequent round would result in failure of shield function. | FAT* | Analysis |
General Testing Requirements
| Ref # | Requirement Description | Acceptance Event(s) | Verification Method | |
| General Requirement | Range Start Up/Shutdown | It takes no more than 30 minutes to start up the range at the beginning of the training session and 30 min to shut down the range at the end of the training session | AT | Demonstration |
| General Requirement | Battle Effects Simulator (BES) | BES fires as required, when applicable | FAT/AT | Demonstration |
| SOW 3.5.6 | Technical Manuals | All BATL and supplemental manuals are provided per SOW/DO | AT | Inspection |
| SOW 3.5.7 | New Equipment Training | New Equipment Training has been completed | AT | Inspection |
| BATL Target Mechanisms | |||||
| PS 3.1.1 | BATL Performance | Time to raise/lower the mechanisms meet the Table 1 requirements | FAT/AT | Demonstration | |
| PS 3.1.1 | BATL Performance | Time to raise/lower the mechanisms in <=35 MPH wind meet the Table 1 requirements | FAT | Demonstration | |
| PS 3.1.1 | BATL Performance | Mechanisms are <= max weight listed in Table 1 | FAT | Demonstration | |
| PS 3.1.1 | BATL Performance | Mechanisms meet the minimum target visibility requirement listed in Table 1 | AT | Inspection | |
| PS 3.1.1 | BATL Performance | Each mechanisms cycle test meets the cycles per hour requirement listed in Table 1 | AT | Demonstration | |
| PS 3.1.1 | BATL Performance | Each mechanisms cycle test meets half the cycles per 24 hour requirement listed in Table 1 | FAT | Demonstration | |
| PS 3.1.1 | BATL Performance | Moving mechanisms meet the speed and distance requirements listed in Table 1 | FAT | Demonstration | |
| General Requirement | Mechanism Ports | Mechanisms contain no loose connections/ports | FAT/AT | Inspection | |
| PS 3.1.2 | Stability | ||||
| Equipment necessary to maintain the position of the stationary TMs and the rail of the moving TMs in the emplacement are provided | AT | Inspection | |||
| PS 3.1.2 | Stability | The stability method used allows for removal of the TM without damage to the TM | FAT | Inspection | |
| PS 3.1.2 | Stability | The TMs hold their respective targets upright and remain stable in winds up to 35 mph | FAT | Demonstration | |
| PS 3.1.2 | Stability | The TMs perform all required functions without the system recording false hits, tipping over, or other malfunctions. | FAT/AT | Inspection | |
| PS 3.1.7 | |||||
| SOW 3.2.3.2 | Silhouette | All silhouettes installed are per DO requirement and as defined in Appendix A | AT | Inspection | |
| PS 3.1.7 | Silhouettes | All silhouettes are securely installed | AT | Inspection | |
| PS 3.2.8 | Protection | Downrange targetry devices and other support devices (except for the Solar panels, ILS, ALS, IMS, antennae, and IMKZT) are sized to fit inside the emplacement and are not subject to damage from rounds fired from the designated firing position | AT | Inspection | |
| SOW 3.3.3 | Range Data | TMs provide initial status and operational status feedback on/within TRACR | FAT/AT | Inspection | |
| General Requirement | Hit Detection (All TM's) | Mechanisms interface with Targetry Range Automated Control and Recording (TRACR) software hit sensitivity adjustment levels. | FAT | Demonstration | |
| General Requirement | Hit Detection (All TM's) | RCS detects and scores a hit when the TM begins to raise the target and through each TMs full exposure time | FAT | Demonstration | |
| General Requirement | Hit Detection (All TM's) | Mechanisms stop reporting hits to the RCS when the TM starts to lower the target | FAT | Demonstration | |
| SOW 3.3.4 | Lightening Protection | The equipment includes protection against lightning that passes over the range or strikes near the range | FAT* | Analysis | |
| SOW 3.3.4.2 | Grounding | All installed hardware is connected to a ground rod in each emplacement | AT | Inspection | |
| SOW 3.4.5.2 | Scenario Testing | Scenarios ran as required without any false hits on the target mechanisms and/or did not report out of communication/target failures. | AT | Demonstration | |
| SOW 3.5.4 | Item Unique Identification (IUID) | IUID labels are present on all required mechanisms/devices | FAT/AT | Inspection |
| Range Work | |||||
| PS 3.2 | Range Work | All emplacement/range work required is per the delivery order and environmental requirements | AT | Inspection | |
| PS 3.2 | |||||
| SOW 3.3 | Range Work | All mechanisms are integrated with the range computer station using the power and data supplied, or as specified in the delivery order | AT | Inspection | |
| PS 3.2.7 | Target position | Zinc coated hardware is used to anchor contractor provided equipment | FAT* | Analysis | |
| PS 3.2.7.1 | Existing Target Position Equipment | Bolts are level with the floor and/or anchor bolts are removed w/o damaging the emplacement further than the holes already made by the bolt. Holes are capped | AT | Inspection | |
| SOW 3.3.4 | Lightening Protection | All lightning protection systems are developed in accordance with NFPA 780, 2023 Edition (Except Chapters 9-11). | FAT* | Analysis | |
| SOW 3.3.4 | Lightening Protection | Transient and surge protection devices are provided for all power lines | FAT* | Analysis | |
| SOW 3.3.4 | Lightening Protection | The lightning protection system for the power lines include an indicator status light, be modular, and support ease of maintenance and replacement. | FAT | Inspection | |
| SOW 3.3.4.2 | Grounding | Replaced ground cables are 6 AWG copper conductors and are mechanically bonded to the existing ground rod | AT | Inspection |
| Power | ||||
| General Requirement | Central Power Switch | All downrange targetry devices are not negatively affected by turning on/shutting down the range by way of the central power switch. | AT | Demonstration |
| PS 3.2.10.1.1 | Power Source | Target mechanisms are powered by DC only | FAT | Inspection |
| PS 3.2.10.1.1 | Power Source | Commercially available outlet adapters and power converters accommodating range outlet(s) is provided | AT* | Analysis |
| PS 3.2.10.1.1 | Power Source | Power converters use 240V AC only for input power (unless otherwise specified in the DO) | FAT/GAT | Inspection |
| PS 3.2.10.1.2 | Power Interfaces | All electrical circuitry are installed and grounded IAW applicable local, state, and federal electrical codes and regulations (i.e., NFPA 70) | AT* | Analysis |
| PS 3.2.10.1.2 | Power Interfaces | All hardware installed in emplacements are electrically grounded to the grounding rods. | AT | Inspection |
| PS 3.2.10.1.4 | OCONUS Power | The hardware installed on the ranges are altered as necessary to operate with the local voltage and frequency requirements | AT* | Analysis |
| PS 3.2.10.1.4 | OCONUS Power | The hardware is equipped with the electrical connectors required to receive the local voltage and frequency. | AT* | Analysis |
| PS 3.2.10.1.5 | Loss of Power | All devices, including battery chargers and power supplies, are protected from damage in the event of loss of AC power. | FAT* | Analysis |
| PS 3.2.10.2.1 | Generators | Diesel fuel powered generators and/or gasoline powered generators are used | FAT | Inspection |
| PS 3.2.10.2.1 | Generators | Fuel tanks are labeled with the type of fuel used. | FAT | Inspection |
| PS 3.2.10.2.1 | Generators | Generators have fuel tank capacity sized to support 20 hrs of training at the required cycle rates between refueling | FAT* | Analysis |
| PS 3.2.10.2.1 | Generators | Generators meet local, state, and federal laws and regulations (this includes fuel containers) | FAT* | Analysis |
| PS 3.2.10.2.1 | Generators | Generators are equipped with a Ground Fault Circuit Interrupt (GFCI) outlet | FAT | Inspection |
| PS 3.2.10.2.1 | Generators | Generators include a protective frame (Excluding MIT/MATs on board generators) | FAT | Inspection |
| PS 3.2.10.2.1 | Generators | Generators are equipped with a fuel gauge | FAT | Inspection |
| PS 3.2.10.2.1 | Generators | Generators include a wheel kit (Excluding MIT/MATs on board generators) | FAT | Inspection |
| PS 3.2.10.2.1 | Generators | Generators include a fuel spill containment pan (Excluding MIT/MATs on board generators) | FAT | Inspection |
| PS 3.2.10.2.1 | Generators | Generators provide a L14-30 receptacle ® | FAT | Inspection |
| PS 3.2.10.2.1 | Regeneration Devices | The regeneration devices provide power to operate the range for 24/7 on a continuous basis without loss of training to regenerate the power. | FAT* | Analysis |
| PS 3.2.10.2.1 | Regeneration Devices | Regeneration units have features that protect against overcharging and overheating the battery | ||
| FAT* | Analysis | |||
| PS 3.2.10.2.2 | Battery Powered Devices | Batteries are sealed Lithium Iron or Absorbent Glass Mat (AGM) | FAT | Inspection |
| PS 3.2.10.2.2 | Battery Powered Devices | Each battery is equipped with carrying handles. All batteries are commercially available from multiple sources. | FAT | Inspection |
| PS 3.2.10.2.2 | Battery Powered Devices | On board batteries meet the specifications defined in the BATL TDP | FAT | Inspection |
| PS 3.2.10.2.3 | Battery Sizing | Batteries supplying power within an emplacement are sized to support the operational capability (see Table 1) of all devices in that emplacement. | AT* | Analysis |
| PS 3.2.10.2.3 | Battery Sizing | Batteries on a moving TM are sized to support the operational capacity of all installed lifters, and all other devices the moving TM is required to carry and power. | AT* | Analysis |
| PS 3.2.10.2.4 | Battery Charging | Battery chargers are approved for use with the chemical composition of the batteries provided under the DO | FAT* | Analysis |
| PS 3.2.10.2.4 | Battery Charging | The battery charger limits float charge to between 2.25 and 2.3 volts per cell at 68 degrees Fahrenheit (F). | FAT* | Analysis |
| PS 3.2.10.2.4 | Battery Charging | The battery charger is spark proof such that leads must be connected before an output voltage is developed by the battery charger | FAT* | Analysis |
| PS 3.2.10.2.4 | Battery Charging | The battery charger is short circuit protected such that the charger can sustain an indefinite short circuit connection directly across the output terminals without risk of electric shock or excessive heat. | FAT* | Analysis |
| PS 3.2.10.2.4 | Battery Charging | The battery charger is reverse polarity protected such that leads being connected to the opposite polarity post will not cause damage to either the battery or the charger | FAT* | Analysis |
| PS 3.2.10.2.4 | Battery Charging | The battery charger is UL tested and approved | FAT* | Analysis |
| PS 3.2.10.2.5 | Battery Charging Station (BCS) | Battery Charging Stations charges all battery types used on downrange devices | FAT* | Analysis |
| PS 3.2.10.2.6 | Solar Panels | Solar panels are UL1703 rated | AT | Inspection |
| PS 3.2.10.2.6 | Solar Panels | A charge controller is provided with each solar panel assembly connected to a battery | FAT | Inspection |
| PS 3.2.10.2.6 | Solar Panels | The charge controller regulates the voltage | FAT* | Analysis |
| PS 3.2.10.2.6 | Solar Panels | The charge controller prevents overcharging of the battery | FAT* | Analysis |
| PS 3.2.10.2.6 | Solar Panels | The battery controller provides protection for reverse polarity | FAT* | Analysis |
| PS 3.2.10.2.6 | Solar Panels | The battery controller provides protection for transient voltage | FAT* | Analysis |
| PS 3.2.10.2.6 | Solar Panels | The battery controller provides protection for over current | FAT* | Analysis |
| PS 3.2.10.2.6 | Solar Panels | The battery controller provides protection for over temperature | FAT* | Analysis |
| Communication | |||||
| PS 3.2.11.2 | |||||
| PS 3.2.11.3 | HW/RF Communication | All required communication interfaces are in the NEMA enclosures | AT | Inspection | |
| PS 3.2.11.2 | |||||
| PS 3.2.11.3 | HW/RF Communication | All NEMA rated enclosures maintain the NEMA rating at the conclusion of installation | AT | Inspection | |
| PS 3.2.11.2 | |||||
| PS 3.2.11.3 | HW Communication | All holes not used in the NEMA enclosures are plugged with NEMA 4 rated enclosure plugs to maintain the NEMA rating | AT | Inspection | |
| PS 3.2.11.2.3 | Network Devices | Network equipment not installed in a climate control environment operates at temp between -20 and 120 degrees | FAT* | Analysis | |
| PS 3.2.11.2.4 | VDSL Modems | Meet all requirments of 3.2.11.2.4 in the Performance Specifications | FAT* | Anaylsis | |
| PS 3.2.11.3.1 | RF Communication | Radio used meets BATL specifications and frequency specifications in the DO | FAT/AT* | Analysis | |
| PS 3.2.11.3.1 | Frequency Band | Transmitters and receivers operate using either the 138 to 160 Megahertz (MHz) Very High Frequency (VHF), 380-400 MHz Ultra High Frequency (UHF), the 406 to 420 MHz (UHF), the 900 MHz (802.11ah), the 2.4 Gigahertz (GHz) (802.11b/g/n/ax/be), or 5 GHz (802.11a/h/j/n/ac/ax/be) bands | FAT* | Anaylsis | |
| PS 3.2.11.3.1 | Frequency Band | The HHC, RCC, and all RF down range receivers/transmitters are tunable through each band by range support personnel without changing internal components | FAT | Demonstration | |
| PS 3.2.11.3.1 | Frequency Band | RF transmitters/receivers meet all Federal Communications Commission (FCC) requirements. | FAT* | Analysis | |
| PS 3.2.11.3.1 | Frequency Band (Portable) | Portable targetry devices include the VHF, UHF and/or WiFi bands | FAT | Inspection | |
| PS 3.2.11.3.2 | Radio Approval | The radio(s) have a JF/12 number or is in the process of being approved | FAT/AT* | Analysis | |
| PS 3.2.11.3.2 | Radio Approval | Radios are in a NEMA 4 rated enclosure (unless otherwise specified in the DO) | AT | Inspection | |
| PS 3.2.11.3.3 | Transceiver Bandwidth | All UHF and VHF radio transmitters and receivers utilize narrow bandwidth technology (12.5 kilohertz (kHz) or less) IAW the National Telecommunications and Information Administration (NTIA). | FAT* | Analysis | |
| PS 3.2.11.3.4 | Tuning Devices | All equipment required to tune the transmitters/receivers are provided with the installation of the range. | AT | Inspection | |
| PS 3.2.11.3.6 | Transmitter Power Adjustment | Power output of the transmitters are adjustable in at least 5 steps | FAT* | Analysis | |
| PS 3.2.11.3.6 | Transmitter Power Adjustment | The adjustment in power communicates with targetry devices at distances up to 5 miles (up to 3 miles for ranges where the HHC is the only RCS controller) | FAT* | Analysis | |
| PS 3.2.11.3.7 | Radio Antennas | Antennas are within emplacements and protected from rounds fired from firing line and/or placed outside the emplacement (off to the side) if proper LOS cannot be established | AT | Inspection | |
| PS 3.2.11.3.8 | Antenna Safety | Antenna tips or other sharp rods have tip caps or other suitable design fixture to prevent puncture hazards where personnel are likely to be exposed to such hazards. | FAT | Inspection | |
| PS 3.2.11.3.8 | Antenna Safety | Where design considerations permit, antennas are coated with a dielectric material to insulate against at least 10,000 volts Root Mean Squared (RMS). | FAT* | Analysis | |
| PS 3.2.11.3.8 | Antenna Safety | Antenna masts incorporate a ground stud with the necessary hardware to permit secure attachment of a ground strap/rod. | AT | Inspection | |
| PS 3.2.11.3.8 | Antenna Safety | Lead-in wires have discharge units (lightning arrestors) on each conductor or enclosure in a continuous metallic shield that is effectively grounded; coaxial cable lead-in may be used as is if the outer shields are grounded at both ends | AT | Inspection | |
| PS 3.2.11.3.8 | Antenna Safety | Antennas and other devices that carry sufficient RF voltage to burn or injure personnel are protected from accidental contact in the same manner as for AC voltages. | AT | Inspection | |
| PS 3.2.11.3.8 | Antenna Safety | Microwave or RF radiation signs are permanently affixed to warn personnel of danger zones. | AT | Inspection |
| Thermals | |||||
| PS 3.3.2.1 | AC Thermals | All AC powered stationary mechanisms have a thermal interface cable/set up with an interface box that mates with the mechanism auxillary thermal receptacle and provides a Locking (L) 5-20 Receptacle on the thermal side | FAT/AT | Inspection | |
| PS 3.3.2.1 | AC Thermals | All AC powered mechanisms Interface box is rated Ingress Protection (IP) 67 | FAT* | Analysis | |
| PS 3.3.2.1 | AC Thermals | The AC powered MATs have a thermal interface cable/set up with an interface box that mates with the mechanism auxillary thermal receptacle and provides a Locking (L) 5-20 Receptacle on the thermal side | pending decision in PS | ||
| PS 3.3.2.1 | AC Thermals | A 36" long cable with a L5-20 plug on one side and a two pin SAE connector on the other is provided for all AC thermal interfaces | FAT/AT | Inspection | |
| PS 3.3.2.1 | |||||
| PS 3.3.2.2 | AC/DC Thermals | All thermals turn on/off from RCS | FAT/AT | Demonstration | |
| PS 3.3.2.2 | DC Thermals | All stationary mechanisms that are not HW for power have a thermal interface cable/setup with an interface box mating to the target auxillary thermal receptacle on one side and provides a two pin SAE connector on the target side | FAT/AT | Inspection | |
| PS 3.3.2.2 | DC Thermals | All MATs not in HW emplacements have a thermal interface cable/setup with an interface box that mates with the target mechanism auxilary thermal receptacle on one side and a two pin SAE connector on the target side | FAT/AT | Inspection | |
| PS 3.3.2.2 | |||||
| PS 3.3.2.3 | DC/MIT Thermals | The cable with the two pin SAE connector is a minimum of 36" long | FAT/AT | Inspection | |
| PS 3.3.2.3 | MIT Thermals | All MITs have a thermal interface cable/setup that mates with the mechanisms auxillary thermal receptacle on one side and provides a two pin SAE connector on the target side | FAT/AT | Inspection | |
| PS 3.3.2.3 | MIT Thermals | DC power draws directly from the target mechanism auxillary thermal receptacle | FAT/AT | Demonstration |
| Cables, Wires & Surge Protection | ||||
| PS 3.1.9.1 | Interface Cabling | Cables are mechanically and electrically insulated. Holes are large enough to allow the cable to be freely drawn through the opening. Cables are protected with conduit or PVC sleeving. | AT* | Analysis |
| PS 3.2.11.2.2 | Cable Interfaces | All downrange devices include enclosure mounted twist lock or threaded connectors for all external connections | AT | Inspection |
| PS 3.2.11.2.2 | Cable Interfaces | All external connections, including TDP/MTDPs and Ferrous Deep (FD) boxes, include a mating twist lock or threaded cap, tethered to the device. | AT | Inspection |
| PS 3.2.11.2.2 | Cable Interfaces | All MTDP/TDPs, CJBs and/or FD Boxes have the M12 Speedcon connector installed | AT | Inspection |
| PS 3.2.11.2.2 | Cable Interfaces | If an FD box is present on the range, the blank face plate is removed and a face plate that includes one (1) M12 Speedcon connector is installed onto the FD box | AT | Inspection |
| PS 3.2.11.2.2 | Cable Interfaces | The face plate shall maintain a NEMA 3R rating for the FD Box | AT | Inspection |
| PS 3.2.11.2.2 | Cable Interfaces | If an FD box is not present on the range these connectors are mounted to the side wall of the TDP/MTDP enclosure facing the emplacement power receptacles | AT | Inspection |
| PS 3.2.11.2.5 | Surge Protection | The surge protectors are grounded IAW manufacturer specifications | AT | Inspection |
| PS 3.2.11.2.5 | Surge Protection | Surge protectors are lightning rated | AT* | Analysis |
| PS 3.2.11.2.5 | Surge Protection | Surge protector response time is 1 - 5 Nanoseconds | AT* | Analysis |
| PS 3.2.11.2.5 | Surge Protection | The surge protectors are Underwriter’s Laboratory (UL) listed | AT* | Analysis |
| PS 3.2.11.2.5 | Surge Protection | Surge protection devices in the TDP/MTDP fit in a 5 inch (”) wide by 6” long by 6” deep space. | FAT | Inspection |
| PS 3.2.11.2.5.1 | Surge protection for Ethernet. | Surge protectors meet or exceed TIA-568-C.2 Standards for CAT5e performance. | AT* | Analysis |
| PS 3.2.11.2.5.1 | Surge protection for Ethernet. | Surge protectors shall utilize RJ-45 connectors for input/output | AT* | Analysis |
| PS 3.2.11.2.5.1 | Surge protection for Ethernet. | Surge protection devices in target emplacements can be auto-resettable | AT | Demonstration |
| PS 3.2.11.2.5.1 | Surge protection for Ethernet. | The surge protection device have a clipping voltage between 12-20 Volts (V) | AT* | Analysis |
| PS 3.2.11.2.5.1 | Surge protection for Ethernet. | Surge protectors protect the equipment on the targetry side from lightning and other surges | AT* | Analysis |
| PS 3.2.11.2.5.2 | Surge protection for VDSL | The surge protection device have a peak clamping voltage Between 48 and 300 Volts (V) | AT* | Analysis |
| PS 3.2.11.2.5.2 | Surge protection for VDSL | The surge protection device have a maximum shunt capacitance of 95 picofarads. | AT* | Analysis |
| PS 3.2.11.2.6 | Cables and Patch Cords | The vendor provided and installed patch cords and adapters between the surge protectors, the modem, and the existing range data cables | AT | Inspection |
| PS 3.2.11.2.6 | Cables and Patch Cords | Vendors did not terminate RJ-45 connectors into RJ-11 ports and vice versa. | AT | Inspection |
| PS 3.2.9 | Power and data wires/cables | All cables necessary to interface with the range infrastructure and to operate the targetry devices are provided | AT | Inspection |
| PS 3.2.9 | Power and data wires/cables | Cables are IAW applicable local and national electrical codes. Cable are not lengthened by splicing if discovered to be too short within an emplacement | AT | Inspection |
| PS 3.2.9 | Power and data wires/cables | Short cables are replaced with cables of the proper length. CAT 5E, 6, or 7 data cabling are color coded IAW TIA-568-C2. | AT | Inspection |
| PS 3.2.9 | Power and data wires/cables | Exterior wires and cables are armored and sealed to prevent damage by non-human living organisms found on ranges | FAT* | Analysis |
| PS 3.2.9 | Power and data wires/cables | Interior wires and cables are positioned or protected to avoid pinching, contact with rough or irregular surfaces and sharp edges to avoid damage to conductors | FAT/AT | Inspection |
| SOW 3.3.4 | Lightening Protection | Data/communication cables are shielded. The individual data lines are electrically isolated from the electronic control circuitry in the equipment and have appropriate transient and surge protection | FAT* | Analysis |
| Production | ||||
| SOW 3.2.4 | QA/QC | QA/QC plan and processes for vendor supplies per SOW 3.2.4 | FAT | Inspection |
| SOW 3.2.5 | Workmanship | All surfaces, including threads, are free of burrs and sharp edges and in compliance to the BATL TDP assembly instructions | FAT/AT | Inspection |
| TDP/Drawings/TM | Workmanship | BATL mechanisms are made according to the BATL TDP/drawing packages | FAT | Inspection |
| General Requirement | Workmanship | All interior parts and surfaces of the devices are thoroughly cleaned and dried, and are free of dust, burrs, chips, grinding compound, mold release agents, or other debris | AT | Inspection |
| TDP/Drawings/TM | Material Safety Considerations | Liquids are IAW BATL TDP/Drawing/TM requirements | FAT | Inspection |
| TDP/Drawings/TM | Adhesives | Applied Adhesives meet the requirements of the TDP/Drawing/TM | FAT | Inspection |
| SOW 3.2.6 | Materials/Commercial Components | All materials are of uniform quality and condition, and free from seams, cracks, and other defects that may adversely affect the strength, endurance, wear, and corrosion resistance of the part | FAT/AT | Inspection |
| SOW 3.2.7 | Corrosion Resistance | All exposed surfaces are constructed of or treated with a corrosion resistant material | FAT* | Analysis |
| Materials/Commercial Components | Material defects are not concealed | AT | Inspection | |
| SOW 3.4.1 | Water Submersion | Mechanisms (not including carriers) can be totally submerged in water for 4 hrs. | FAT | Demonstration |
| PS 3.3.1.1 | Materials/Commercial Components | Materials are not subject to damage by non-human living organisms on exposed portions of downrange equipment | FAT/AT | Inspection |
| PS 3.3.1.1 | Materials/Commercial Components | Materials of construction use commercial or military standard components, parts, and assemblies of reliable construction | FAT* | Analysis |
| Labeling | ||||
| PS 3.3.1.2 | Safety | Warning labels for equipment and moving parts that describe potential hazards are provided | FAT/AT | Inspection |
| SOW 3.5.9 | Identification Plates/Contractor Plate | A plate is located in the tower near the computer. | AT | Inspection |
| SOW 3.5.9 | Identification Plates/Contractor Plate | If there isn’t a tower on the range, then the contract data plate is attached to the HHC in a location that does not interfere with battery replacement | AT | Inspection |
| SOW 3.5.9 | Identification Plates/Contractor Plate | Contract data plates installed on the HHC withstand the installation location's environmental conditions | AT* | Analysis |
| SOW 3.5.9 | Identification Plates/Contractor Plate | The contract data plates identify the requirements in this section | AT | Inspection |
| SOW 3.5.10.1 | Mechanism Labels | Targetry device ports and cables are labeled | FAT/AT | Inspection |
| SOW 3.5.10.2 | Cable Labels | All cables installed are labeled at each cable termination and are legible | AT | Inspection |
| SOW 3.5.10.3 | Server Room Labels | All lines in the range tower, server room or other area associated with the equipment installation are clearly labeled and legible | AT | Inspection |
| Additional Range Equipment and Requirements | ||||
| PS 3.3.1.3 | Transportation of Hardware | Equipment to be carried or lifted by personnel have handles and/or grasp areas that meet MIL-STD-1472G paragraph 5.8.6.5.3 | FAT* | Analysis/Inspection |
| PS 3.3.1.4 | Service Life | Vendor provided equipment is constructed to achieve a minimum service life of 20 years, except for batteries. | FAT* | Analysis |
| PS 3.3.1.5 | Environmental Requirements | All contractor provided equipment and materials not installed in a climate controlled enclosure or structure on the range operate under the specified environmental conditions without damage or loss of performance (Unless otherwise noted in the applicable RFDOP) | FAT* | Analysis |
KD_IM_Testing Requirements
| Ref # | Requirement Description | Acceptance Event(s) | Verification Method | |
| Iron Maiden Targets | ||||
| PS 3.3.5 | Iron Maiden Targets | Iron Maidens consist of three pieces: the IMKZT, the base, and the IMS | FAT | Inspection |
| PS 3.3.5 | Iron Maiden Targets | The material(s) used for the IMS and IMKZT do not present ricochet hazards to the shooters when fired upon at distances between 100m and 1,000m (.50 Cal will be fired upon at a minimum of 400m). | FAT* | Analysis |
| PS 3.3.5.1 | Target Base | The Iron Maiden base holds the IMS and the IMKZT at their established positions described in paragraphs 3.3.5.2 & 3.3.5.3. | FAT | Demonstration |
| PS 3.3.5.1 | Target Base | All stabilization components are provided with the base | FAT/AT | Inspection |
| PS 3.3.5.1 | Target Base | Stabilization methods of anchoring into the ground are not used. | FAT/AT | Inspection |
| PS 3.3.5.1 | Target Base | All components of the target base fit behind and are fully protected by the IMS | FAT/AT | Inspection |
| PS 3.3.5.1 | Target Base | The target base includes carrying handles for portability purposes. | FAT | Inspection |
| PS 3.3.5.1 | Target Base | The target base is considered part of the IMKZT. | FAT | Inspection |
| PS 3.3.5.2 | Iron Maiden Silhouettes (IMS) | IMSs have an E-type target shape and are within the parameters of Appendix B | FAT | Inspection |
| PS 3.3.5.2 | Iron Maiden Silhouettes (IMS) | The IMS are made out of through hardened 3/8”, AR500 steel. | FAT* | Analysis |
| PS 3.3.5.2 | Iron Maiden Silhouettes (IMS) | The Kill Zone area are cut out of the target to the dimensions of APPENDIX B | FAT* | Analysis |
| PS 3.3.5.2 | Iron Maiden Silhouettes (IMS) | The Kill Zone area provides an open space for rounds to pass through to the IMKZT | FAT | Inspection |
| PS 3.3.5.2 | Iron Maiden Silhouettes (IMS) | IMSs withstand 500 rounds of 7.62mm and 1000 rounds of 5.56mm shot into a 3” square area with no evidence of penetration such that a subsequent round would result in failure of shield function | FAT* | Analysis |
| PS 3.3.5.2 | Iron Maiden Silhouettes (IMS) | The IMS are angled forward 80 degrees to 85 degrees from horizontal. | FAT* | Analysis |
| PS 3.3.5.2 | Iron Maiden Silhouettes (IMS) | When angled, the IMS and the Kill Zone cut-out area dimensions are sized to present to the shooter a target with the dimensions shown in APPENDIX B | FAT* | Analysis |
| PS 3.3.5.2 | Iron Maiden Silhouettes (IMS) | Four (4) carrying handles are attached to the silhouette | FAT | Inspection |
| PS 3.3.5.2 | Iron Maiden Silhouettes (IMS) | Two handles are at the base and two shall be at the shoulder, on each side of the IMS | FAT | Inspection |
| PS 3.3.5.2 | Iron Maiden Silhouettes (IMS) | The method of attaching the handles to the IMS do not alter the ballistic properties of the IMS. | FAT | Demonstration |
| PS 3.3.5.3 | Iron Maiden Kill Zone Target (IMKZT) | IMKZTs is made out of through hardened, 3/8”, AR500 steel | FAT* | Analysis |
| PS 3.3.5.3 | Iron Maiden Kill Zone Target (IMKZT) | IMKZTs is positioned behind the kill zone area of the silhouette | FAT | Inspection |
| PS 3.3.5.3 | Iron Maiden Kill Zone Target (IMKZT) | IMKZTs dimensions are at least 2” larger than the kill zone area dimensions of the IMS. | FAT | Inspection |
| PS 3.3.5.3 | Iron Maiden Kill Zone Target (IMKZT) | IMKZTs provide a visual queue to the shooter and spotter when it receives a hit | FAT | Demonstration |
| PS 3.3.5.3 | Iron Maiden Kill Zone Target (IMKZT) | The visual feedback is more than a round impact disrupting a painted surface | FAT | Inspection |
| PS 3.3.5.3 | Iron Maiden Kill Zone Target (IMKZT) | If the determined visual queue requires the IMKZTs to be moved by the round to show it has been hit, then the IMKZTs include an auto reset mechanism (without user intervention) to bring the target back to its original position | FAT | Demonstration |
| PS 3.3.5.3 | Iron Maiden Kill Zone Target (IMKZT) | The visual feedback method is moveable by a minimum of a fired 7.62mm round throughout the 100-1000m range | FAT* | Analysis |
| Known Distance Lifters | ||||
| PS 3.3.4 | Known Distance (KD) Lifters | KD lifters raise and lower 72” by 72” framed targets IAW training requirements stated in FM 3-22.9 | FAT | Inspection |
| PS 3.3.4 | Known Distance (KD) Lifters | KD lifters are anchored to the emplacement. | AT | Inspection |
| PS 3.3.4 | Known Distance (KD) Lifters | The anchoring method withstands constant winds up to and including 35 mph. | FAT | Demonstration |
| PS 3.3.4.1 | KD Lifting Capabilities | All target lifting features are fully protected by the emplacement. | AT | Inspection |
| PS 3.3.4.1 | KD Lifting Capabilities | The KD lifter fully exposes and fully conceas a 72” by 72” target above and behind, respectively the emplacement wall | AT | Inspection |
| PS 3.3.4.1 | KD Lifting Capabilities | If a roller chain and sprocket solution is utilized, bearings are lifetime lubricated or greaseless, and roller chains and sprockets require lubrication no less than every 1,000 lifts | FAT* | Analysis |
| PS 3.3.4.1 | KD Lifting Capabilities | Chains meet ANSI B 29.1M requirements | FAT* | Analysis |
| PS 3.3.4.1 | KD Lifting Capabilities | Chains can be repaired by replacing individual links | FAT | Demonstration |
| PS 3.3.4.1 | KD Lifting Capabilities | The total lift weight of the KD lifter components and target to be raised is no more than 40 lbs to the operator. | FAT | Demonstration |
| PS 3.3.4.1 | KD Lifting Capabilities | The target locks into position at the target mounting position, the fully exposed position, and the fully concealed. | AT | Demonstration |
| PS 3.3.4.1 | KD Lifting Capabilities | The lifter requires the operator to manually release the locking method to move to the desired position | AT | Demonstration |
| PS 3.3.4.1 | KD Lifting Capabilities | The locking setup is releasable by one hand in less than 1 second. | FAT | Demonstration |
| PS 3.3.4.2 | KD Platform | KD platforms are free standing and moveable. Platforms shall be a minimum of 20" by 20" (L” x W”). | FAT | Inspection |
| PS 3.3.4.2 | KD Platform | The design working load of the movable platform is calculated on the basis of one or more 200 lb persons with 50 lbs of equipment each. | FAT* | Analysis |
| PS 3.3.4.2 | KD Platform | The moveable platform is constructed to carry a working load of 75 lbs per square foot. | FAT* | Analysis |
| PS 3.3.4.2 | KD Platform | The platformis slip resistant | FAT | Inspection |