This document is a set of three sample Delivery Order Proposals (DOPs) for three separate federal contract opportunities related to outfitting live-fire training ranges.
The DOPs provide detailed requirements for the installation of automated targetry devices, communication equipment, power infrastructure, and other ancillary hardware at ranges located at Camp Rilea, OR (Rilea ARF Range 14), Joint Base Lewis-McChord, WA (JBLM ARF Range 12), and Yakima Training Center, WA (Yakima MPTR Range 86). The requirements cover specifications for stationary and moving infantry and armor targets, cabling, power, data communication, and environmental considerations. Key deliverables include installation, training, spare parts, and acceptance testing. The proposals include pricing, delivery timelines, and quality assurance requirements. These DOPs appear to be related to a broader Live Training, Ranges, and Combat Training Centers (LTRaC) Multiple Award Contract (MAC) acquisition by the Department of the Army Materiel Command Contracting Command Orlando (ACC-ORL).
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Rilea ARF Range 14
* SAMPLE *
Delivery Order Proposal
| Army Contracting Command - Orlando | Contractor: | Control #: |
| Address: | Date: | |
| POC: | ||
| POC PHONE: |
| STATEMENT OF WORK: | |
| 1. | Installation: Camp Rilea, OR |
| 2. | Range Type: 16 Lane Modified Record Fire (MRF) Range, Range 14 |
| 3. | Range Description: Contractor shall supply all targetry devices, hardware, installation, training, and travel for an operational Automated Record Fire (ARF) Range at Camp Rilea, OR IAW the Performance Specification (PS) and Section C requirements, and the requirements of this Delivery Order Proposal (DO). |
| 4. | Range Design Specifications. The emplacements are Hardwired (HW) for both power and data. Camp Rilea will remove existing target mechanisms (TMs) but will leave cables and brackets in place. The contractor shall remove any existing cables and hardware attached to the emplacement that the contractor does not plan to use per Section 3.2.7.1 of the PS. Contractor provided brackets shall meet SIT mechanism adjustability requirements per Section 3.1.3 of the PS. See attached pictures. |
SIT Emplacements: All SIT emplacements are concrete and are 56" x 48" (W x L). Emplacements at the 50m position have a 20” high front wall, emplacements at the 100m and 150m positions have an 18 ½” high front wall, and emplacements beyond the 150m position have a 16 ½” high front wall. All SIT emplacements have Cable Junction Boxes (CJBs) that contain power and data.
75m and 175m Emplacements: The contractor shall not install SIT TMs in the 75m and 175m emplacements. The contractor shall install all required power and data equipment in the existing 75m and 175m Cable Junction Boxes to ensure connectivity with the rest of the range.
Removed Components: The contractor is responsible for turning over all removed components to the range POC.
5. Power: The range has 220/110 VAC power available; however, only 220VAC is available at the emplacements because of missing neutral wire. As 110VAC power is not available at the emplacements, the thermals shall be powered through the auxiliary power port of the SIT. Each SIT shall not exceed the 700 VA limit while raising a target or lowering a target.
Cable Junction Boxes (CJBs): The contractor shall replace existing Cable Junction Boxes (CJBs) and their mounting rails with new contractor provided CJBs and mounting rails. New CJBs shall be 20" x 16" x 6" and be NEMA 4 rated. The contractor shall provide new L14-20R receptacles on the contractor provided CJBs. The contractor shall install circuit breakers rated for no greater than 20 amps in the circuit serving the L14-20R outlets inside the CJBs. The contractor shall bond the cable shield conductor to ground in all emplacements and in the panel board serving power to all the targets. Emplacements at the 75m and 175m positions shall not receive new CJBs or L14-20Rs.
SDA/TJB: No Signal Distribution Assembly (SDA) exists inside the tower. A Tower Junction Box exists at the base of the tower. The contractor shall install a NEMA 5-15R for the VDSL modems in the TJB as needed. The dimensions of the TJB are 30" x 36" with a depth of 8".
L14-20R and plugs: Weatherproof, in-use wet location covers shall be provided with Ethylene propylene rubber gaskets around the face of the receptacles. The receptacles shall accept a male plug with a diameter of 1.8" - 1.95". The contractor shall provide male L14-20 Plugs (P) with diameter of 1.8"-1.95" for all TMs, which shall prevent the entrance of moisture and dirt when connected to the associated receptacles.
6. Data Communication: The range is HW for data with twisted pair wires. The contractor shall interface with the existing 19 AWG twisted pair data wiring terminated in Cable Junction Boxes (CJB) for all emplacements. The contractor shall install a cable interface per Section 3.2.11.3.2 of the PS on the side of each CJB facing the TM. All targetry devices shall be Internet Protocol (IP) addressable via Ethernet, and shall communicate directly to TRACR II software. The contractor shall provide all new data components in the TJB.
VDSL Modems: The contractor shall provide very high bit digital subscriber line (VDSL) modems that support auto-speed configuration for line ports. The modem shall provide bandwidth of up to 100Mbps symmetric over line ports. The modem shall be configurable for local and remote modes. The modem shall support packet sizes up to 1,536 bytes. The modem shall provide wide-range dual power input (DC12V ~ 48V). The modem shall provide reverse polarity protection. The modem shall be Ingress Protection (IP) 30 compliant. The contractor shall install the tower VDSL modems within the TJB. VDSL modems shall not be daisy chained together in the tower, but each shall be routed to one Ethernet switching/multiplexing device and from the Ethernet device to the computer. The modems shall be installed so that each is not subjected to heat affects from another modem and other equipment installed in the same box. In order to minimize overheating of modems, the modems shall be installed so that maximum air space within the box and maximum separation between units is accomplished. The power supplies for the VDSL modems shall be set at 24V or greater.
| 7. | Site Specific Environmental Requirements: N/A |
| 8. | DSL Surge Protection: The contractor shall use the SP that is internal to the DSL modem and ground IAW manufacturer specifications. |
Power Surge Protection: The contractor shall install power line surge protection into the CJBs per Section 3.2.11.3.5 of the PS.
| 9. | Targetry Device and Ancillary Equipment Variations: See below. | |
| 1. | Thermal Interfaces (AC): All requirements of Section 3.3.2 of the PS for thermal requirements apply for each emplacement. | |
| 2. | Infantry Silhouettes: Contractor shall provide and install 3-D silhouettes per drawing 11829332 on all infantry lifters except only one half size 3-D target shall be installed in the right 50m (if facing downrange) emplacement. Silhouettes shall be priced with each Infantry TM in the associated CLIN. | |
| 10. | Install Start Date: DDMMYYY. The contractor shall contact the FASIT Range Systems APM Jill McVay, email: jill.l.mcvay.civ@army.mil, prior to shipping targetry. | |
| 11. | Install Completion Date: DDMMYYY. The contractor shall contact the FASIT Range Systems APM Jill McVay NLT than this date notifying the Government they are ready for Acceptance Testing. | |
| 12. | New Equipment Training Date: DDMMYYY. | |
| 13. | Acceptance Test Date: DDMMYYY | |
| 14. | Delivery Order Completion Date: DDMMYYY | |
| 15. | Contract Data Requirements List Submissions: TBD | |
| 16. | Quality Assurance: First Article Testing (FAT) is required for equipment not previously tested successfully; otherwise, range acceptance testing is required. The contractor shall complete all FAT requirements ahead of time to ensure this delivery schedule is met. The contractor shall build the FAT in their Integrated Master Schedule (IMS) and present this during Integrated Product Team (IPT) meetings with the Government counterparts. |
Test Readiness Review (TRR): The contractor shall hold a teleconference NLT 7 days prior to the Acceptance Test Date to ensure readiness. This meeting shall include at a minimum the TACOM FASIT Range Systems APM, DEVCOM, TPO Ranges, and Range Representatives for this project.
| 17. | Property Accountability: Vendors shall submit inventory data IAW Scope of Work (SOW) Sections 3.5.1 and 3.5.4. |
| 18. | FOB: Destination |
| 19. | Shipping POC: TBD |
| 20. | DODAAC: TBD |
| 21. | Ship to Address: TBD |
| CLIN | Description | Qty | Notes | Unit Price | Price | |
| 001AA | Camp Rilea Range 14 Fielding | Stationary Infantry Target (SIT) | 114 | 2 not to be installed (spare mechanisms) | $ - 0 | $ - 0 |
| Communication Interfaces | 112 | Emplacements requiring Communication Interfaces | $ - 0 | $ - 0 | ||
| Site Visit | 1 | $ - 0 | $ - 0 | |||
| Shipping Costs | $ - 0 | |||||
| Installation Costs | 1 | Tower communication interfaces / VDSL Tower Upgrade | $ - 0 | $ - 0 | ||
| Installation | $ - 0 | |||||
| Total Installation Cost | $ - 0 | |||||
| Manuals | # Digital/# Hard Copy | $ - 0 | $ - 0 | |||
| New Equipment Training | $ - 0 | |||||
| 002AA | Travel | Travel for Install | $ - 0 | |||
| 003AA | Spares Package | Spare Parts Package | Spare parts for all TMs. See "Spare Parts Packages" Tab | $ - 0 | ||
| TOTAL OFFERED RANGE PRICE | $0.00 | |||||
| (Prices valid for 60 days) |
| CONTRACTOR SIGNATURE: | *SAMPLE |
| (Person authorized to bind your company contractually) |
JBLM ARF Range 12
* SAMPLE *
Delivery Order Proposal
| Army Contracting Command - Orlando | Contractor: | Control #: |
| Address: | Date: | |
| POC: | ||
| POC PHONE: |
| STATEMENT OF WORK: | |
| 1. | Installation: Joint Base Lewis-McChord, WA |
| 2. | Range Type: 16 Lane Modified Record Fire (MRF) Range, Range 12 |
| 3. | Range Description: Contractor shall supply all targetry devices, hardware, installation, training, and travel for an operational Automated Record Fire (ARF) Range at Joint Base Lewis-McChord (JBLM), WA, IAW the Performance Specification (PS) and Section C requirements, and the requirements of this Delivery Order Proposal (DO). |
| 4. | Range Design Specifications. The emplacements are Hardwired (HW) for both power and data. JBLM will remove existing target mechanisms (TMs) but will leave cables and brackets in place. The contractor shall remove any existing cables and hardware attached to the emplacement that the contractor does not plan to use per Section 3.2.7.1 of the PS. Contractor provided brackets shall meet SIT mechanism adjustability requirements per Section 3.1.3 of the PS. See attached pictures. |
SIT Emplacements: All SIT emplacements are concrete and are 54" x 48" x 18" (W x L x H). All SIT emplacements have a power and a data box that are 8" x 10" x 4" each. The Unistrut that the power and data boxes are mounted on is 24" in length. The contractor shall remove the existing data box and add a new contractor provided Target Data Panel (TDP) on the emplacement wall, see drawing provided in pictures package. To make room for the new TDP, the contractor shall cut down the existing Unistrut so that it only supports the existing power box and slide over and re-attach the support bracket. The contractor shall use new Unistrut to attach the contractor provided TDP to the emplacement wall. The dimensions of the TDP in the provided drawing are 16" x 12" x 8".
75m and 175m Emplacements: The contractor shall not install SIT TMs in the 75m and 175m emplacements. The contractor shall install all required power and data equipment in the existing 75m and 175m power and data boxes to ensure connectivity with the rest of the range. The contractor shall not remove the existing data box or add a TDP to the 75m and 175m emplacements. The contractor shall not add a new juction box or circuit braekers to the 75m and 175m emplacements.
Removed Components: The contractor is responsible for turning over all removed components to the range POC.
5. Power: The range is HW at 240/120 VAC, 60 Hz. The contractor shall provide a new junction box, new L5-20R, and new L14-20R on the wall of the emplacement and use a liquid-tight flexible metallic conduit to connect power from the existing power box to the new junction box, see provided drawing. The contractor shall install circuit breakers rated for no greater than 20 amps in the circuit serving the NEMA L5-20R and L14-20R inside the new junction box. The contractor shall bond the cable shield conductor to ground in all emplacements and in the panel board serving power to all the targets. Each TM shall be powered by 240 VAC only. Each SIT shall not exceed the 700 VA limit while raising a target or lowering a target.
SDA/TJB: A Tower Junction Box (TJB) exists at the base of the control tower. Currently, no outlets exist in the TJB. The contractor shall install a NEMA 5-15R for the VDSL modems in the TJB as needed. The dimensions of the TJB are 30" x 36" with a depth of 8". There is no Signal Distribution Assembly (SDA) inside the tower.
L14-20R and L5-20Rs and plugs: Weatherproof, in-use wet location covers shall be provided with Ethylene propylene rubber gaskets around the face of the receptacles. The receptacles shall accept a male plug with a diameter of 1.8" - 1.95". The contractor shall provide male L14-20 Plugs (P) with diameter of 1.8"-1.95" for all TMs, which shall prevent the entrance of moisture and dirt when connected to the associated receptacles.
6. Data Communication: The range is currently hardwired for data with twisted pair wires. The contractor shall interface with the existing 19 AWG twisted pair data wiring which shall be terminated in the contractor provided TDPs for all emplacements. The contractor shall use a liquid-tight flexible metallic conduit to connect power from the power box to the new TDP. All targetry devices shall be Internet Protocol (IP) addressable via Ethernet, and shall communicate directly to TRACR software. The contractor shall provide all new data components in the TJB.
VDSL Modems: The contractor shall provide very high bit digital subscriber line (VDSL) modems that support auto-speed configuration for line ports. The modem shall provide bandwidth of up to 100Mbps symmetric over line ports. The modem shall be configurable for local and remote modes. The modem shall support packet sizes up to 1,536 bytes. The modem shall provide wide-range dual power input (DC12V ~ 48V). The modem shall provide reverse polarity protection. The modem shall be Ingress Protection (IP) 30 compliant. The contractor shall install the tower VDSL modems in the TJB. VDSL modems shall not be daisy chained together in the tower, but each shall be routed to one Ethernet switching/multiplexing device and from the Ethernet device to the computer. The modems shall be installed so that each is not subjected to heat affects from another modem and other equipment installed in the same box. In order to minimize overheating of modems, the modems shall be installed so that maximum air space within the box and maximum separation between units is accomplished. The power supplies for the VDSL modems shall be set at 24V or greater.
| 7. | Site Specific Environmental Requirements: N/A |
| 8. | DSL Surge Protection: The contractor shall use the SP that is internal to the DSL modem and ground IAW manufacturer specifications. |
Power Surge Protection: The contractor shall install power line surge protection into the junction boxes per Section 3.2.11.3.5 of the PS.
| 9. | Targetry Device and Ancillary Equipment Variations: See below. | |
| 1. | Thermal Interfaces (AC): All requirements of Section 3.3.2 of the PS for thermal requirements apply for each emplacement. | |
| 2. | Infantry Silhouettes: Contractor shall provide and install 3-D silhouettes per drawing 11829332 on all infantry lifters except only one half size 3-D target shall be installed in the right 50m (if facing downrange) emplacement. Silhouettes shall be priced with each Infantry TM in the associated CLIN. | |
| 10. | Install Start Date: DDMMYYY. The contractor shall contact the FASIT Range Systems APM Jill McVay, email: jill.l.mcvay.civ@army.mil, prior to shipping targetry. | |
| 11. | Install Completion Date: DDMMYYY. The contractor shall contact the FASIT Range Systems APM Jill McVay NLT than this date notifying the Government they are ready for Acceptance Testing. | |
| 12. | New Equipment Training Date: DDMMYYY. | |
| 13. | Acceptance Test Date: DDMMYYY | |
| 14. | Delivery Order Completion Date: DDMMYYY | |
| 15. | Contract Data Requirements List Submissions: TBD | |
| 16. | Quality Assurance: First Article Testing (FAT) is required for equipment not previously tested successfully; otherwise, range acceptance testing is required. The contractor shall complete all FAT requirements ahead of time to ensure this delivery schedule is met. The contractor shall build the FAT in their Integrated Master Schedule (IMS) and present this during Integrated Product Team (IPT) meetings with the Government counterparts. |
Test Readiness Review (TRR): The contractor shall hold a teleconference NLT 7 days prior to the Acceptance Test Date to ensure readiness. This meeting shall include at a minimum the TACOM FASIT Range Systems APM, DEVCOM, TPO Ranges, and Range Representatives for this project.
| 17. | Property Accountability: Vendors shall submit inventory data IAW Scope of Work (SOW) Sections 3.5.1 and 3.5.4. |
| 18. | FOB: Destination |
| 19. | Shipping POC: TBD |
| 20. | DODAAC: TBD |
| 21. | Ship to Address: TBD |
| CLIN | Description | Qty | Notes | Unit Price | Price | ||
| 004AA | JBLM ARF Range 12 Fielding | Stationary Infantry Target (SIT) | 114 | 2 not to be installed (spare mechanisms) | $ - 0 | $ - 0 | |
| Communication Interfaces | 112 | Emplacements requiring Communication Interfaces | $ - 0 | $ - 0 | |||
| Site Visit | 1 | $ - 0 | $ - 0 | ||||
| Shipping Costs | $ - 0 | ||||||
| Installation Costs | 1 | Tower communication interfaces / VDSL Tower Upgrade | $ - 0 | $ - 0 | |||
| Installation | $ - 0 | ||||||
| Total Installation Cost | $ - 0 | ||||||
| Manuals | # Digital/# Hard Copy | $ - 0 | $ - 0 | ||||
| New Equipment Training | $ - 0 | ||||||
| 005AA | Travel for Install | Travel for Install | $ - 0 | ||||
| 006AA | Spare Parts Package | Spare Parts Package | Spare parts for all TMs. See "Spare Parts Packages" Tab | $ - 0 | |||
| TOTAL OFFERED RANGE PRICE | $0.00 | ||||||
| (Prices valid for 60 days) | |||||||
| CONTRACTOR SIGNATURE: | *SAMPLE | ||||||
| (Person authorized to bind your company contractually) |
Yakima MPTR Range 86
* SAMPLE *
Delivery Order Proposal
| Army Contracting Command - Orlando | Contractor: | Control #: |
| Address: | Date: | |
| POC: | ||
| POC PHONE: |
| STATEMENT OF WORK: | |
| 1. | Installation: Yakima Training Center, WA |
| 2. | Range Type: Multi-Purpose Training Range (MPTR), Rg 86 |
| 3. | Range Description: Contractor shall supply all targetry devices, hardware, installation, training, and travel for an operational MPTR at Yakima Training Center, WA, IAW the Performance Specification (PS) and Section C requirements, and the requirements of this Delivery Order Proposal (DO). |
| 4. | Range Design Specifications. The MPTR is Hardwired (HW) for both power and data located approximately 4 hours from Joint Base Lewis-McChord (JBLM), WA. The installation will remove existing target mechanisms (TMs) but will leave brackets in place. The contractor shall remove any existing cables and hardware attached to the emplacement that the contractor does not plan to use per Section 3.2.7.1 of the PS. Contractor provided brackets shall meet SIT mechanism adjustability requirements per Section 3.1.3 of the PS. See attached pictures and drawings. |
SIT Emplacements: There are 60 SIT emplacements, grouped in clusters (8 groups of 7, and 1 group of 4). SIT emplacements are concrete with dimensions of 54" wide by 48" deep and with a 30" high front wall.
SAT Emplacements: There are 24 SAT emplacements. SAT emplacements are concrete and are 14' wide by 12' deep and have a wall height of 53". All SAT emplacements have concrete floors for the SATs.
MAT Emplacements: There are 4 MAT emplacements. All MAT emplacements have bunkers and have tracks that are straight. All MATs have tracks that measure 350m in length, including the distance into the bunkers. All MATs have gravel track beds and 60” high concrete walls. The installation will remove the existing MAT tracks but leave timbers and gravel bed in place. CJBs containing power and data for the MATs are located inside the bunkers. The installation plans to continue to use the bunkers with the new MATs.
Non-Hardwired Emplacements: There are 14 non-hardwired SIT emplacements on this range. These emplacements shall not recieve new TMs.
Removed Components: The contractor is responsible for turning over all removed components to the range POC.
5. Power: The range is Hardwired (HW) for power at 120/240VAC. Each SIT shall not exceed the 700 VA limit while raising a target or lowering a target.
Cable Junction Boxes (CJBs): The existing Cable Junction Boxs (CJBs) are 20" x 16" x 6". If the contractor cannot use existing CJB holes in each emplacement, the contractor shall plug all holes in the CJBs on the range with National Electrical Manufacturers Association (NEMA) 4 rated enclosure plugs. The plugs shall maintain the overall NEMA rating of the enclosure when installed. The plugs shall be removable without the use of special tools or solvents. All CJBs shall maintain an NEMA 4 rating after installation. All CJBs have latch type lids that are removable (no hinges). The contractor shall install a three-pole power splicer terminal block and isolate the neutral in the target emplacement. Each TM shall be powered by 240 VAC only.
SIT and SAT Power: The contractor shall provide new L5-20R and L14-20R receptacles on the existing CJBs. The contractor shall install circuit breakers rated for no greater than 20 amps in the circuit serving the NEMA L5-20R and L14-20R outlets inside the CJBs. SATs shall recieve two L5-20Rs. The existing maintanence receptacle shall remain in use but the contractor shall replace the covers.
MAT Power: The CJBs for the MAT are located inside the MAT bunkers. The contractor shall run conduit from the CJB to a new contractor provided power statuion which shall be located on the second 60" wall panel from the bunkers enterence.
SDA/TJB: Currently, no outlets exist in the Tower Junction Box (TJB) or Signal Distribution Assembly (SDA). The contractor shall install a NEMA 5-15R for the VDSL modems in the SDA as needed. The dimensions of the SDA are 30" x 42" with a depth of 11".
L14-20R and L5-20Rs and plugs: Weatherproof, in-use wet location covers shall be provided with Ethylene propylene rubber gaskets around the face of the receptacles. The receptacles shall accept a male plug with a diameter of 1.8" - 1.95". The contractor shall provide male L14-20 Plugs (P) with diameter of 1.8"-1.95" for all TMs, which shall prevent the entrance of moisture and dirt when connected to the associated receptacles.
6. Data Communication: The range is currently hardwired for data. The contractor shall interface with the existing 19 AWG twisted pair data wiring terminated in Cable Junction Boxes (CJB) for all emplacements. The contractor shall install a cable interface per Section 3.2.11.3.2 of the PS on the side of each CJB facing the TM. All targetry devices shall be Internet Protocol (IP) addressable via Ethernet, and shall communicate directly to TRACR II software. The contractor shall provide all new data components in the SDA/TJB.
Data Breakout Boxes (DBBs): The MPTR has 7 Data Breakout Boxes (DBBs) throughout the range, including one at each MAT emplacement. The contractor shall use DDBs as part of their communications network. Data from one DDB to the next shall be daisy chained, so that there are no direct runs from the tower to any DDB after DDB 1. DBBs are 30” by 36” and 8” deep. The contractor shall install a NEMA 5-15R for the VDSL modems in the DDB as needed. See diagram in pictures package.
VDSL Modems: The contractor shall provide very high bit digital subscriber line (VDSL) modems that support auto-speed configuration for line ports. The modem shall provide bandwidth of up to 100Mbps symmetric over line ports. The modem shall be configurable for local and remote modes. The modem shall support packet sizes up to 1,536 bytes. The modem shall provide wide-range dual power input (DC12V ~ 48V). The modem shall provide reverse polarity protection. The modem shall be Ingress Protection (IP) 30 compliant. The contractor shall install the tower VDSL modems within the climate controlled tower in the SDA. VDSL modems shall not be daisy chained together in the tower, but each shall be routed to one Ethernet switching/multiplexing device and from the Ethernet device to the computer. The modems shall be installed so that each is not subjected to heat affects from another modem and other equipment installed in the same box. In order to minimize overheating of modems, the modems shall be installed so that maximum air space within the box and maximum separation between units is accomplished. The power supplies for the VDSL modems shall be set at 24V or greater.
| 7. | Site Specific Environmental Requirements: N/A |
| 8. | DSL Surge Protection (SP): The contractor shall use the SP that is internal to the DSL modem and ground IAW manufacturer specifications. |
Power Surge Protection: The contractor shall install power line surge protection into the CJBs per Section 3.2.11.3.5 of the PS.
| 9. | Targetry Device and Ancillary Equipment Variations: See below. | |
| 1. | Thermal Interfaces (AC): All requirements of Section 3.3.2 of the PS for thermal requirements apply for each emplacement. | |
| 2. | Infantry Silhouettes: Contractor shall provide and install 3-D silhouettes per drawing 11829332 on all infantry lifters. Silhouettes shall be priced with each Infantry TM in the associated CLIN. | |
| 3. | MAT Track: Existing MAT tracks shall be removed by the installation. The contractor shall provide MAT track per Section 3.2.6 of the PS and its subsections. MATs require 350m of track each. Stated track lengths include the distance into the bunkers. | |
| 10. | Install Start Date: DDMMYYY. The contractor shall contact the FASIT Range Systems APM Jill McVay, email: jill.l.mcvay.civ@army.mil, prior to shipping targetry. | |
| 11. | Install Completion Date: DDMMYYY. The contractor shall contact the FASIT Range Systems APM Jill McVay NLT than this date notifying the Government they are ready for Acceptance Testing. | |
| 12. | New Equipment Training Date: DDMMYYY. | |
| 13. | Acceptance Test Date: DDMMYYY | |
| 14. | Delivery Order Completion Date: DDMMYYY | |
| 15. | Contract Data Requirements List Submissions: TBD | |
| 16. | Quality Assurance: First Article Testing (FAT) is required for equipment not previously tested successfully; otherwise, range acceptance testing is required. The contractor shall complete all FAT requirements ahead of time to ensure this delivery schedule is met. The contractor shall build the FAT in their Integrated Master Schedule (IMS) and present this during Integrated Product Team (IPT) meetings with the Government counterparts. |
Test Readiness Review (TRR): The contractor shall hold a teleconference NLT 7 days prior to the Acceptance Test Date to ensure readiness. This meeting shall include at a minimum the TACOM FASIT Range Systems APM, DEVCOM, TPO Ranges, and Range Representatives for this project.
| 17. | Property Accountability: Vendors shall submit inventory data IAW Scope of Work (SOW) Sections 3.5.1 and 3.5.4. |
| 18. | FOB: Destination |
| 19. | Shipping POC: TBD |
| 20. | DODAAC: TBD |
| 21. | Ship to Address: TBD |
| CLIN | Description | Qty | Notes | Unit Price | Price | |
| 007AA | Yakima MPTR Range 86 Fielding | Stationary Infantry Target (SIT) | 62 | 2 not to be installed (spare mechanisms) | $ - 0 | $ - 0 |
| Stationary Armor Target (SAT) | 26 | 2 not to be installed (spare mechanisms) | $ - 0 | $ - 0 | ||
| Moving Armor Target (MAT) | 4 | $ - 0 | $ - 0 | |||
| MAT Track | 4 | Each MAT shall include 350 meters of track | $ - 0 | $ - 0 | ||
| Communication Interfaces | 95 | Emplacements requiring interfaces, including DBBs | $ - 0 | $ - 0 | ||
| Site Visit | 1 | $ - 0 | $ - 0 | |||
| Shipping Costs | $ - 0 | |||||
| Installation Costs | 1 | Tower communication interfaces / VDSL Tower Upgrade | $ - 0 | $ - 0 | ||
| Installation | $ - 0 | |||||
| Total Installation Cost | $ - 0 | |||||
| Manuals | # Digital/# Hard Copy | $ - 0 | $ - 0 | |||
| New Equipment Training | $ - 0 | |||||
| 008AA | Travel | Travel for Install | $ - 0 | |||
| 009AA | Spares Package | Spare Parts Package | Spare parts for all TMs. See "Spare Parts Packages" Tab | $ - 0 | ||
| TOTAL OFFERED RANGE PRICE | $0.00 | |||||
| (Prices valid for 60 days) |
| CONTRACTOR SIGNATURE: | *SAMPLE |
| (Person authorized to bind your company contractually) |
Spare Parts Packages
| Rilea ARF Range 14 CLIN 003AA | JBLM Range 12 CLIN 006AA | Yakima MPTR Range 86 CLIN 009AA | ||||||||||||
| Device | Part Number | National Stock Number (NSN) | Nomenclature | Unit Price | Quantity | Total Price | Quantity | Total Price | Quantity | Total Price | ||||
| SIT | 277200-001 | ENCLOSURE ASSEMBLY, SIT | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | |||||
| SIT | 277202-001 | ENCLOSURE LID, SIT | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | |||||
| 1 | SIT | 277203-001 | LID GASKET, SIT | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277234-001 | TOGGLE SWITCH, 3 POSITION | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277235-001 | TOGGLE SWITCH, 2 POSITION | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277492-001 | CABLE ASSEMBLY, HIT SENSOR, PLUG | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277236-001 | KNOCK SENSOR | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277487-001 | CABLE PLUG, M12 SPEEDCON, 5 POS | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277493-001 | CABLE ASSEMBLY, POWER INPUT, PLUG | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277495-001 | CABLE ASSEMBLY, MFS LED, PLUG | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277485-001 | AMPHENOL PLUG CONNECTOR, 2 POSITION, DC POWER INPUT | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277489-001 | FLEXIBLE PORTABLE CORD, TYPE SJOOW, 2 CONDUCTORS, 12 AWG, INSULATED | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 3 | SIT | 277483-001 | 5935-01-406-2393 | CONNECTOR,PLUG,ELECTRICAL | $ - 0 | 112 | 17 | $ - 0 | 112 | 17 | $ - 0 | 60 | 9 | $ - 0 |
| 1 | SIT | 277484-001 | BACKSHELL STRAIN RELIEF, AMPHENOL PLUG, 2 POSITION, DC SIGNAL | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277238-001 | HIGH INTENSITY LED SPOTLIGHT | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277490-001 | FLEXIBLE PORTABLE CORD, TYPE SJOOW, 2 CONDUCTORS, 16 AWG, INSULATED | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277501-001 | DATA BULKHEAD CONNECTOR, COUPLING BOARD, ASSEMBLY | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 2 | SIT | 277219-001 | PUSH/PULL TOGGLE CLAMP | $ - 0 | 112 | 11 | $ - 0 | 112 | 11 | $ - 0 | 60 | 6 | $ - 0 | |
| 1 | SIT | 277247-001 | BRACKET, SILHOUETTE HOLDER, SIT | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 2 | SIT | 277248-001 | U CLAMP, SILHOUETTE HOLDER, SIT | $ - 0 | 112 | 11 | $ - 0 | 112 | 11 | $ - 0 | 60 | 6 | $ - 0 | |
| 1 | SIT | 277227-001 | COLE HERSEE REVERSING RELAY, 12V | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277256-001 | COMMAND AND CONTROL MODULE | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277257-001 | XPORT MODULE | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277258-001 | POWER DISTRIBUTION BOARD | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277259-001 | ADDRESSING MODULE | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 1 | SIT | 277210-001 | AUTOTEX G138 | $ - 0 | 112 | 6 | $ - 0 | 112 | 6 | $ - 0 | 60 | 3 | $ - 0 | |
| 2 | SIT | 277223-001 | OPTICAL LIMITS SWITCH | $ - 0 | 112 | 11 | $ - 0 | 112 | 11 | $ - 0 | 60 | 6 | $ - 0 | |
| 3 | SAT | 277230-001 | CBL FEMALE TO WIRE FLUSH TYPE SOCKET, M12 SPEEDCON, 5 POS | $ - 0 | 24 | 4 | $ - 0 | |||||||
| 1 | SAT | 277234-001 | TOGGLE SWITCH, 3 POSITION | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 1 | SAT | 277235-001 | TOGGLE SWITCH, 2 POSITION | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 1 | SAT | 277262-001 | ENCLOSURE ASSEMBLY, SAT | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 1 | SAT | 277264-001 | ENCLOSURE LID, SAT | $ - 0 | 24 | 2 | $ - 0 | |||||||
| 1 | SAT | 277265-001 | LID GASKET, SAT | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 4 | SAT | 277463-001 | ARMOR TARGET HIT SENSOR ASSEMBLY | $ - 0 | 24 | 5 | $ - 0 | |||||||
| 1 | SAT | 277475-001 | SNAP ACTION SWITCH, 15 A MAX | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 1 | SAT | 277477-001 | ENCLOSURE, WATER-TIGHT, MODIFIED, ARMOR HIT SENSOR | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 2 | SAT | 277294-001 | SQUARE U-BOLT, 5/8"-18 THREAD, 4-1/4" INSIDE WIDTH, 8-1/2" LENGTH | $ - 0 | 24 | 2 | $ - 0 | |||||||
| 1 | SAT | 277311-001 | FLANK SILHOUETTE POST HOLDER | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 1 | SAT | 277312-001 | POST HOLDER BASE | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 1 | SAT | 277501-001 | DATA BULKHEAD CONNECTOR, COUPLING BOARD, ASSEMBLY | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 2 | SAT | 277223-001 | OPTICAL LIMITS SWITCH | $ - 0 | 24 | 2 | $ - 0 | |||||||
| 1 | SAT | 277256-001 | COMMAND AND CONTROL MODULE | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 1 | SAT | 277257-001 | XPORT MODULE | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 1 | SAT | 277258-001 | POWER DISTRIBUTION BOARD | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 1 | SAT | 277259-001 | ADDRESSING MODULE | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 1 | SAT | 277280-001 | HYDRAULIC POWER UNIT, 12V 3000 PSI MAX, 2.5 GPM MAX | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 2 | SAT | 277518-001 | HYDRAULIC HOSE ASSEMBLY, 24" LENGTH | $ - 0 | 24 | 2 | $ - 0 | |||||||
| 4 | SAT | 277658-001 | CABLE FOR SAT HIT SENSOR | $ - 0 | 24 | 5 | $ - 0 | |||||||
| 1 | SAT | 277660-001 | CABLE ASSEMBLY, POWER INPUT, PLUG | $ - 0 | 24 | 1 | $ - 0 | |||||||
| 2 | MAT | 277234-001 | TOGGLE SWITCH, 3 POSITION | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 2 | MAT | 277235-001 | TOGGLE SWITCH, 2 POSITION | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 2 | MAT | 277256-001 | COMMAND AND CONTROL MODULE | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 2 | MAT | 277257-001 | XPORT MODULE | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 2 | MAT | 277258-001 | POWER DISTRIBUTION BOARD | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 2 | MAT | 277280-001 | HYDRAULIC POWER UNIT, 12V 3000 PSI MAX, 2.5 GPM MAX | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 3 | MAT | 277358-001 | PROXIMITY SENSOR | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 1 | MAT | 277425-001 | IEC100-B14 WORM SPEED REDUCER, 7.5 - 1 MOTION RATIO | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 1 | MAT | 277431-001 | HOWLAND MOTOR AME200-0374 | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 9 | MAT | 277439-001 | 12V 55AH SLA BATTERY | $ - 0 | 4 | 2 | $ - 0 | |||||||
| 1 | MAT | 277441-001 | MAT CONTROL UNIT | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 1 | MAT | 277443-001 | CURTIS MOTOR CONTROLLER, MODEL 1236SE | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 2 | MAT | 277256-005 | COMMAND AND CONTROL WITH TWO EXPORT MODULES | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 2 | MAT | 277258-001 | POWER DISTRIBUTION BOARD | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 1 | MAT | 277584-001 | BATTERY MANAGEMENT BOARD (BMB) | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 1 | MAT | 277379-001 | MOTOR CONTROL BOARD | $ - 0 | 4 | 1 | $ - 0 | |||||||
| 1 | MAT | 277573-001 | HALL EFFECT SENSOR, 12V DC | $ - 0 | 4 | 1 | $ - 0 | |||||||
| TOTALS: | $ - 0 | $ - 0 | $ - 0 |