This appendix outlines commercial door and window replacement specifications for the Victor Cullen Center (VCC), a secure treatment facility for Department of Juvenile Services youth located in Sabillasville, Maryland. The project encompasses replacements across eight buildings at the facility: Digges Cottage (2 doors and 2 frames), Mitchell Cottage (4 doors and 4 frames), Prettyman Cottage (4 doors and 4 frames), Raine Cottage (4 doors and 4 frames), Rutledge Cottage (4 doors and 4 frames), Auxiliary Rec (2 doors, 2 frames, and 8 windows), CTE Building (3 doors, 3 frames, and 10 windows), and Gymnasium (7 frames with multiple single and double doors). Door specifications vary by location, with dimensions ranging from 2'6" to 3'0" in width and 80" to 85" in height, featuring configurations such as interior and exterior sally ports, dayrooms, mop sinks, and office spaces. Window quantities total approximately 26 units across multiple buildings with varying dimensions.

All doors shall be constructed of 12-gauge steel with stiffened seamless edges, and frames must be 12-gauge steel welded with hidden anchors. Hardware specifications include LCN closers with track arms, security recessed pulls, Corbin Russwin ML2012 mortise locks, and Corbin 6-pin unpinned L4 keyway cylinders. Windows shall be 12-gauge welded hollow metal single rabbet construction with 20-minute impact-resistant security glazing, which shall also be applied to door lights. Fire rating requirements specify 90-minute ratings for the CTE Interior Bathroom Door and CTE Office Door, with no fire rating required for exterior doors. The gymnasium's new main entrance features a specialized frame configuration of 12 feet wide by 10 feet high with integrated metal plates and lights measuring 32" x 47".

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX 3

COMMERICIAL DOOR AND WINDOW REPLACMENT

VICTOR CULLEN CENTER

Digges Cottage 2 Door & 2 Frames

(1) Interior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” LH Out Swing

(2) Exterior Sally Port

3’0 x 80 Door 6” x 40” x 82” Frame Light 20” x 20” RH Out Swing

Mitchell Cottage 4 Doors & 4 Frames

3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing

(2) Exterior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing

(3) Exterior Dayroom 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing

(4) Mop Sink 2’6” x 80 Door 6” x 34” x 82” Frame Light NONE RH Out Swing

Prettyman Cottage 4 Doors & 4 Frames

(1) Interior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20 LH Out Swing

(2) Exterior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing

(3) Exterior Dayroom 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” LH Out Swing

(4) Mop Sink 2’6”x 80 Door 8” x 34” x 82” Frame Light NONE RH Out Swing

Raine Cottage 4 Doors & 4 Frames

3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” LH Out Swing

(2) Exterior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” LH Out Swing

(3) Exterior Dayroom 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” LH Out Swing

2’6” x 80 Door 8” x 34” x 82” Frame Light NONE RH Out Swing

VICTOR CULLEN CENTER

Rutledge Cottage 4 Doors & 4 Frames

(1) Interior Sally Port (2) 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing

(2) Exterior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing

(3) Exterior Dayroom 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing

2’6” x 80 Door 8” x 34” x 82” Frame Light NONE LH Out Swing

Auxiliary Rec 2 Doors, 2 Frames & 8 Windows Doors/Frames

(1) Main Door 3’0 x 80 Door 6” x 40” x 82” Frame Light NONE RH Out Swing

(2) Rear Door 2’8” x 80 Door 6” x 36” x 82” Frame Light NONE LH Out Swing

Windows

(1) 8 at Approximately 36 ½” x 46 ½”

CTE Building 3 Doors, 3 Frames & 10 Windows Doors/Frames

(1) Front Door 3’0 x 80 Door 7” x 40” x 82” Frame Light NONE RH Out Swing

(2) Interior Bathroom 2’6” x 80 Door 5” x 34” x 82” Frame Light NONE LH Out Swing

(3) Office 3’0 x 80 Door 5” x 40” x 82” Frame Light 20” x 20” RH Out Swing

Windows

(1) 1 at 33 ½’ x 48 ¾”

(2) 4 at 33 ½’ x 40 ½”

(3) 5 at 35” x 47”

Gymnasium 4 Single & 3 Double Doors & 7 Frames

(1) Main Entrance 3’0 x 85 Door 6” x 10’ x 12’ Frame Light 20” x 20” RH Out Swing 3’0 x 85 Door N/A Light 20” x 20” LH Out Swing

(2) Mechanical Room – New Doors Unequal Pair to Achieve 36” Opening

2’6” x 85 Door 6” x 64” x 88” Frame Light NONE RH Out Swing 2’6” x 85 Door N/A Light NONE LH Out Swing

(3) Equipment Room – New Doors Unequal Pair to Achieve 36” Opening 2’6” x 85 Door 6” x 64” x 88” Frame Light NONE RH Out Swing 2’6” x 85 Door N/A Light NONE LH Out Swing

(4) Gym Floor 1 3’0 x 85 Door 6” x 40” x 88” Frame Light 20” x 20” LH Out Swing

(5) Gym Floor 2 3’0 x 85 Door 6” x 40” x 88” Frame Light 20” x 20” RH Out Swing

(6) Gym Floor 3 3’0 x 85 Door 6” x 40” x 88” Frame Light 20” x 20” RH Out Swing

(7) Exterior Office 3’0 x 85 Door 6” x 40” x 88” Frame Light NONE RH Out Swing

Door Materials or Equivalent Doors – 12-Gauge Steel Stiffened Seamless Edges Frames – 12-Gauge Steel Welded & Hidden Anchors Closer – LCN with Track Arm to Match Existing Pulls – Security Recessed Lights – Match Existing Sizes

* Mortise – Corbin Russwin ML2012 (Must Be Used) *Cylinder – Corbin 6-Pin Unpinned L4 Keyway (Must Be Used) Cylindrical Locks – Corbin Russwin Grade 1 Hinges – Heavy Duty Security/Prison Grade

Window Materials or Equivalent Windows – 12 Gauge Welded Hollow Metal Single Rabbet Security Glazing with ¾” 20-minute impact resistant/attack rating security glazing (Also to be used in door lights)

Fire Rating CTE Interior Bathroom Door & CTE Office Door – 90 Minute Exterior Door – N/A

APPENDIX I

COMMERICAILA DOOR AND WINDOE REPLACMENT

Gym New Main Entrance

Metal Plate

Light 32” x 47”

Door 3’0 x 85”

20” x 20”

Door 3’0” x 85”

20” x 20”

32” x 47”

Frame 12’W x 10’H PAGE 4 OF 4