This is a Commercial Solution Opportunity solicitation issued by the Defense Commissary Agency (DeCA) for total maintenance services at military commissaries in the Kaiserslautern Military Community (KMC) area in Germany.
DeCA seeks innovative commercial maintenance solutions from firms operating in the European Union for three commissary locations: Baumholder, Vogelweh, and Ramstein. The scope of work encompasses preventative maintenance (PM), emergency maintenance (EM), and unscheduled maintenance (UM) for HVAC systems, facilities, and equipment. Specific requirements include: implementing scheduled PM activities guided by manufacturer and Department of War (DoW) requirements with PM intervals documented in Attachment 1; providing 24/7/365 emergency response with a guaranteed 3-hour on-site arrival time; delivering reactive maintenance with prompt firm-fixed-price estimates and rapid work completion; submitting regular performance reports concurrent with invoices; and ensuring full compliance with DoW, German, and EU laws and regulations. All solutions must include parts and labor warranties meeting EU and host nation standards. The contract period is for up to five years. Interested vendors must submit a written solutions brief (Phase 1) in accordance with section 3.2. The closing date is 26 August 2026 at 3:00 PM Central European Time (CET). Questions should be directed to Nicholas Ruppert, Contract Specialist (Nicholas.Ruppert@deca.mil), or Daniel Ellis, Contracting Officer (Daniel.Ellis@deca.mil).
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Commercial Solution Opportunity – Defense Commissary Agency
In accordance with the Commercial Opportunity Solution – Defense Commissary Agency (DeCA), dated
04/10/2026, paragraph 5.0, the following specific requirement in support of 5.5 Modernize Business is attached.
The Defense Commissary Agency (DeCA) is seeking innovative, commercial approaches from firms operating in European Union, fully in compliance with EU and host nation specific regulations and standards. Scope of work is for total maintenance services which include maintenance for HVAC systems, facilities, and equipment for the commissaries within the Kaiserslautern Military Community (KMC) area which include the commissaries at Baumholder, Vogelweh, and Ramstein. The goal is to leverage industry best practices, modern technologies, and creative service models to improve reliability, accountability and overall service quality for total maintenance services within the KMC area. DeCA seeks solutions that will provide this support for up to five total years. Attachment 1 and other supporting document contains technical data that will provide assistance in understanding current conditions that the commercial solution proposal will need to meet.
Interested vendors with proven expertise in providing maintenance services in a commercial grocery setting should submit their written solutions brief (Phase 1) in accordance with section 3.2 Solutions Brief.
Seeking solutions to include:
Implement preventative maintenance (PM) a scheduled, proactive maintenance performed on operational equipment and facilities—guided by manufacturer, local, and DOW requirements—to minimize failure risks, extend asset lifespans, and guarantee safety and compliance. Provide PM Intervals in column L on updated Attachment 1 Current Inventory.
Provide emergency maintenance (EM), 24/7/365 emergency response with a guaranteed 3-hour on-site arrival time or industry standard to prevent threats to life, safety, HVAC systems, and grocery inventory.
Provide unscheduled maintenance (UM), reactive, unplanned maintenance activities triggered by unexpected equipment failure, performance drops or, on demand; requiring action to restore normal operations and compliance.
Provide procedures and timelines for UM, including prompt submission of firm-fixed-price estimates and rapid work completion upon approval.
Provide reports and supporting documentation to ensure accurate representation of work performed.
Regular reporting concurrent to invoice submittal on contract performance. .
Ensure operations comply with DoW, German, and EU laws, while providing parts and labor warranties that meet EU/host nation regulations and industry standards.
The closing date for this opportunity is 26 August 2026 at 3:00 PM Central European Time (CET).
All communications to include questions pertaining to this opportunity shall be sent via email to the following Points of Contact:
Nicholas Ruppert – Contract Specialist (Nicholas.Ruppert@deca.mil)
Daniel Ellis – Contracting Officer (Daniel.Ellis@deca.mil) mailto:Nicholas.Ruppert@deca.mil mailto:Daniel.Ellis@deca.mil
Store Name Inventory Number Equipment Name
Statement of Objective
Baumholder 529 Handicap Cart DONT RUN
Baumholder 529 Handicap Cart Check and add/update inventroy INVENTORY AND CHECK
Baumholder 522 Split Unit Air Conditioning
Air Conditioning Unit in Cash Office is not operational. Office has no windows or other ventilation.
Baumholder 520 Display, Self Contained (Stand Alone Display) TOO wARM
Baumholder 519 Display, Self Contained (Stand Alone Display) Makes a loud noise
Baumholder 518 Baler REPAIR STRING HOLDER
Baumholder 515 Display, Self Contained (Stand Alone Display) COMPRESSOR 1 BROKEN
Baumholder 513 Condensing Unit NEEDS COOLING FLUID
Baumholder 513 Condensing Unit LEAK IN PIPE
Baumholder 513 Condensing Unit Leak Search
Baumholder 512 Condensing Unit LEAK IN PIPE
Baumholder 512 Condensing Unit Leak Search
Baumholder 512 Condensing Unit COMPRESSOR DON 'T RUN
Baumholder 511 Distribution Panels, Electrical DISPLAY BROKEN
Baumholder 510 Display, Self Contained (Stand Alone Display) Leak in cooling system
Baumholder 504 Water Treatment System (building water supply) water Leak
Baumholder 503 Water Heater, Electric NO HOT wATER
Baumholder 461 Ice Maker Is not cold enough
Baumholder 459 Bakery Cabinet, Self Service Bread box broken
Baumholder 458 Display, Self Contained (Stand Alone Display) ELECTRIC PROBLEM, DONT wORK
Baumholder 458 Display, Self Contained (Stand Alone Display) LOUD NOISES, TOO wARM
Baumholder 458 Display, Self Contained (Stand Alone Display) REPAIR COVER
Baumholder 457
Industrial Kitchen Equipment (Mixers etc., not fixed installation)
KITCHEN UNIT MIXER BROKEN
Baumholder 457
BROKEN
Baumholder 456 Scale and Scale Labeler
Includes the invoice from the Boss Scale Center for the maintenance of the scales as discussed over the phone with Mr. Groh. This work order was opened by Nikolaos Kastrinos from wISAG.
Baumholder 455 Baler DONT RUN
Baumholder 454 Oven, Baking and Roasting HEATER BROKEN
Baumholder 454 Oven, Baking and Roasting baking Oven and Proofer inoperational
Baumholder 454 Oven, Baking and Roasting DONT RUN
Baumholder 454 Oven, Baking and Roasting LOCK BROKEN AND DOOR HANDLE
Baumholder 454 Oven, Baking and Roasting DONT RUN
Baumholder 454 Oven, Baking and Roasting Does not run
Baumholder 454 Oven, Baking and Roasting wATER LEAK
Baumholder 449 Display, Self Contained (Stand Alone Display) Too warm
Baumholder 449 Display, Self Contained (Stand Alone Display) NOT CHARGING
Baumholder 440 Display, Self Contained (Stand Alone Display) NOT wORKING, LIGHTNING STRIKE
Baumholder 439 Display, Self Contained (Stand Alone Display) NOT wORKING
Baumholder 439 Display, Self Contained (Stand Alone Display) too warm
Baumholder 439 Display, Self Contained (Stand Alone Display) TOO wARM
Baumholder 438 Pallet Jack, Electric Drawer bar broken off
Baumholder 434 Scale and Scale Labeler Does not run
Baumholder 429 Slicer (Bread, Deli, Bistro) Repair broken parts.
Baumholder 423 Warehouse shelve REPAIR BROKEN SHELVES
Baumholder 420 Exit Lights (per store x) repair broken ones and replace those in LED that do not work correctly (checkout area)
Baumholder 420 Exit Lights (per store x) Change accu 's
Baumholder 420 Exit Lights (per store x) CHANGE BROKEN LIGHT
Baumholder 413 Grounds Maintenance (sole DeCA use) INSTALL FIRE EXTINGUISHER
Baumholder 411 Water Treatment System (building water supply) FILTER BROKEN
Baumholder 409 Oven, Proofer Repair hose
Baumholder 409 Oven, Proofer Repair broken handle
Baumholder 408 Oven, Baking and Roasting Repair hose
Baumholder 408 Oven, Baking and Roasting DONT RUN
Baumholder 408 Oven, Baking and Roasting NOT HEATING UP
Baumholder 408 Oven, Baking and Roasting OVEN DONT RUN
Baumholder 390 Distribution Panels, Electrical REP BROKEN COVER
Baumholder 377 Forklift DOOR BROKEN
Baumholder 345 Grill, Rotary Electric (Rotisserie) MISSING SCREwS, REPLACE
Baumholder 341 Condensing Unit FAN BROKEN
Baumholder 328 Display, Self Contained (Stand Alone Display) wATER LEAK INSIDE
Baumholder 328 Display, Self Contained (Stand Alone Display) LOUD NOISES
Baumholder 328 Display, Self Contained (Stand Alone Display) BAU 000329-000330 ICED UP
Baumholder 315 Condensing Unit DONT RUN
Baumholder 314 Condensing Unit BAU000314 - BAU000317 EXTRA CLEANING
Baumholder 283 Pallet Jack, Electric Does not run.
Baumholder 283 Pallet Jack, Electric BACK wHEELS NOT wORKING PROPERLY
Baumholder 282 Pallet Jack, Electric Repair broken cover.
Baumholder 282 Pallet Jack, Electric COVER BROKEN
Baumholder 282 Pallet Jack, Electric BACK wHEELS NOT wORKING PROPERLY
Baumholder 282 Pallet Jack, Electric Key and switch broken
Baumholder 281 Pallet Jack, Electric Check battery.
Baumholder 281 Pallet Jack, Electric BACK wHEELS NOT wORKING PROPERLY
Baumholder 280 Pallet Jack, Electric DON 'T CHARGE BATTERY
Baumholder 280 Pallet Jack, Electric BACK wHEELS NOT wORKING PROPERLY
Baumholder 280 Pallet Jack, Electric Inoperable
Baumholder 280 Pallet Jack, Electric BAU000381 PALLET JACK CHANGE BROKEN wHEEL add to inventroy
Baumholder 279 Pallet Jack, Electric Repair broken handle
Baumholder 279 Pallet Jack, Electric BACK wHEELS NOT wORKING PROPERLY
Baumholder 279 Pallet Jack, Electric DON 'T RUN
Baumholder 278 Pallet Jack, Electric Repair broken cover
Baumholder 278 Pallet Jack, Electric BACK wHEELS NOT wORKING PROPERLY
Baumholder 278 Pallet Jack, Electric Key and lock are broken
Attachment 2: Sample Work Orders: Past 2 Years
Baumholder 271 Display, Self Contained (Stand Alone Display) Freezer is not freezing.
Baumholder 271 Display, Self Contained (Stand Alone Display) ERROR MESSAGE E2
Baumholder 271 Display, Self Contained (Stand Alone Display) DOESN 'T HOLD TEMP
Baumholder 271 Display, Self Contained (Stand Alone Display) REFRIDGE IN BAKERY TO wARM
Baumholder 271 Display, Self Contained (Stand Alone Display) NOT COOLING
Baumholder 218 Sales Area Shelving Repair damaged shelves
Baumholder 217 Kitchen Unit (including Appliances) REPAIR BROKEN BAKERY PANEL
Baumholder 211 Lighting, Sales Area Change broken and blind lights.
Baumholder 211 Lighting, Sales Area NO LIGHT CASH CAGE ROOM
Baumholder 211 Lighting, Sales Area
FE Blackburn: Replace defective fixtures with 62x62 cm LED panels, color tone 3500-4500k (Neutral white) and ensure lumem level per contract/DeCA criteria is met. Fixtures used should be direct 230V type without
LED voltage converter/driver if possible. Provide specification sheet with estimate
Baumholder 211 Lighting, Sales Area CHANGE BROKEN LIGHT
Baumholder 211 Lighting, Sales Area Fault in system (panel)
Baumholder 211 Lighting, Sales Area Change blind bulbs
Baumholder 211 Lighting, Sales Area Sensor is broken
Baumholder 211 Lighting, Sales Area REP LIGHT IN SCANNING OFFICE
Baumholder 210 Lighting, Outside REPAIR BROKEN LIGHT
Baumholder 210 Lighting, Outside
The Commissary sign on the outside of the building only has a small portion that is lit up. Most of the signage lighting is not working.
Baumholder 209 Electrical System Fix and install new cable.
Baumholder 209 Electrical System CHANGE BROKEN OUTLETS IN DELI
Baumholder 209 Electrical System INSTALL NEw PLUG INS ON wALL
Baumholder 209 Electrical System INSTALL PLUGS ON wALL
Baumholder 209 Electrical System No power in commissary
Baumholder 209 Electrical System INSTALL CUSTOMER BELL STORAGE AREA
Baumholder 209 Electrical System FAN TOILETT BROKEN
Baumholder 209 Electrical System
LIGHT RAMP AND COMPLETE FREEZER FE Blackburn - em type updated. Lights failed on ramp and walkin, safety issue
Baumholder 209 Electrical System INSTALL OUTLETS FOR NEw COOLERS
Baumholder 209 Electrical System Install electrical outlet by the lobby for additional refrigeration equipment to be put in
Baumholder 209 Electrical System NO LIGHT ON SALES FLOOR
Baumholder 209 Electrical System INSTALL PLUG FOR FOODwARMER
Baumholder 209 Electrical System REPAIR PLUG CABLE ROLL
Baumholder 209 Electrical System INSTALL PLUG FOR SALAD BAR
Baumholder 208 Doors and Windows LOCK BROKEN OUTSIDE STORAGE
Baumholder 208 Doors and Windows COPY KEYS
Baumholder 208 Doors and Windows CLOSE HOLE IN wINDOw SALVAGE ROOM
Baumholder 208 Doors and Windows REPAIR BROKEN ENTRANCE DOOR
Baumholder 208 Doors and Windows LOCK BROKEN BASEMENT
Baumholder 208 Doors and Windows Key broken-alarm cash cage
Baumholder 208 Doors and Windows CHANGE PLASTIC STRIPES / CURTAINS
Baumholder 208 Doors and Windows CHANGE PLASTIC STRIPES ON CURTAINS
Baumholder 207 Walls COVER wALL wITH METAL PLATES
Baumholder 207 Walls INSTALL TILES ON wALL , SPLASH GUARD
Baumholder 207 Walls CLOSE HOLES ON wALL AND PAINT
Baumholder 207 Walls REPAIR BROKEN BUMBER
Baumholder 207 Walls CHANGE SIGN ON ENTRANCE
Baumholder 207 Walls CLOSE HOLES IN FLOOR (NEw REGISTERS)
Baumholder 207 Walls
Remove plexi glass from cash registers, set aside, install on new check outs. Remove just before removal of old machines, replace on new machines soonest after installation.
Coordinate with store for timing
Baumholder 207 Walls FIX METAL PLATE OUTSIDE
Baumholder 205 Roofing wATER LEAKING INSIDE, CLOSE HOLE IN ROOF
Baumholder 205 Roofing RAINING THRU
Baumholder 205 Roofing Roof on aisle 11 was leaking heavily on Thursday due to heavy rain. Need to patch the hole
Baumholder 205 Roofing ROOF LEAKING
Baumholder 205 Roofing Leak in roof
Baumholder 205 Roofing CLOSE LEAK IN ROOF ENTRANCE AREA
Baumholder 205 Roofing REPAIR PIPE FROM ROOF
Baumholder 205 Roofing LEAK FROM ROOF ON ISLE 3
Baumholder 204 Plumbing and Fixtures Drain in customer bathroom is broken.
Baumholder 204 Plumbing and Fixtures SINK IN BATHROOM CLOGGED
Baumholder 204 Plumbing and Fixtures REPAIR BROKEN MIRROw
Baumholder 204 Plumbing and Fixtures SINK CLOGGED wOMAN BATHROOM
Baumholder 204 Plumbing and Fixtures DRAIN BAKERY BROKEN
Baumholder 204 Plumbing and Fixtures NO wARM wATER IN DELI
Baumholder 204 Plumbing and Fixtures FLUSHER BROKEN MEN TOILETT
Baumholder 204 Plumbing and Fixtures SINK DELI BROKEN, DRAIN
Baumholder 204 Plumbing and Fixtures DRAIN CLOGGED wOMAN BATHROOM ENTRANCE AREA
Baumholder 204 Plumbing and Fixtures wATER OUTLET wOMAN TOILETT BROKEN
Baumholder 204 Plumbing and Fixtures Drain sink is clogged
Baumholder 204 Plumbing and Fixtures Drain pump in Produce is broken
Baumholder 204 Plumbing and Fixtures water coming from pipe behind toilet in women 's front of store restroom
Baumholder 204 Plumbing and Fixtures Remove water-produce
Baumholder 204 Plumbing and Fixtures NO wATER PRESSURE IN DELI
Baumholder 204 Plumbing and Fixtures INSTALL OUTLET FOR ROOF
Baumholder 204 Plumbing and Fixtures DRAIN wOMEN EMPLOYEE CLOGGED
Baumholder 204 Plumbing and Fixtures VALVE BROKEN wARM wATER PIPE
Baumholder 203 Gutters and Downspouts REP BROKEN GUTTER DRAIN
Baumholder 202 Gates and Fences REPAIR BROKEN STRIPES
Baumholder 202 Gates and Fences REPAIR RAILING RAMP
Baumholder 201 Flooring PAINT YELLOw LINES
Baumholder 201 Flooring Remove metal plate on bottom
Attachment 2: Sample Work Orders: Past 2 YearsAttachment 2: Sample Work Orders: Past 2 Years
Baumholder 201 Flooring
Replace 3 metal plates by Front End with regular tile. Used to be power outlets for the old registers, no longer in use, it dips down causing safety hazards. (day work only)
Baumholder 200 Ceilings CHANGE BROKEN CEILING TILES
Baumholder 200 Ceilings Change dirty tiles
Baumholder 200 Ceilings CHANGE BROKEN TILES IN DIRECTORS OFFICE
Baumholder 200 Ceilings CHANGE BROKEN TILES ENTRANCE
Baumholder 200 Ceilings PAINT CLEAN VENTILATION GRILL
Baumholder 188 Warm Air Blower MOTOR BROKEN
Baumholder 187 Warm Air Blower TO wARM
Baumholder 168 Heating System SwITCH TO wINTER TIME
Baumholder 168 Heating System SwITCH TO SUMMER OPERATION
Baumholder 168 Heating System HEATER RESTROOM wOMAN BROKEN
Baumholder 168 Heating System Change system for wintertime
Baumholder 168 Heating System CHANGE PROGRAM SUMMER TIME
Baumholder 168 Heating System HEATER IN CLEANING ROOM BROKEN
Baumholder 168 Heating System CHANGE BROKEN THERMOSTAT
Baumholder 163 Slicer (Bread, Deli, Bistro) PART BROKE OFF
Baumholder 163 Slicer (Bread, Deli, Bistro) NOT wORKING, BROKEN PIECE
Baumholder 163 Slicer (Bread, Deli, Bistro) MOTOR LOUD NOISE
Baumholder 124 Hydraulic Elevating Platform (Dock Leveler/Loading Ramp) PAINT YELLOw LINES
Baumholder 123 Hydraulic Elevating Platform (Dock Leveler/Loading Ramp)
DONT RUN
REAPAIR DAMAGED ELETCTRIC BOX
DONT LIFT UP, NON OPERABLE
DONT RUN
Baumholder 115
Ventilation System (without heating or cooling coil), Exhaust Fans
MOTOR BROKEN
Baumholder 112 Ventilation System
DON 'T RUN FE: If this is the sales area this is known and shut off intentionally. Please coordinate with the
FE 's before turning on.
Baumholder 108 Fire Protection Door
Administration door leading to warehouse needs to be a fire break door with an automatic closure system in case of fire.
Baumholder 106 Alarm System, Fire w/Tableau DISTURBANCE
Baumholder 19 Generator, Diesel DONT TURN OFF
Baumholder 19 Generator, Diesel Fuel- antifreeze fluid
Baumholder 18 Doors, Automatic Entrance and Exit Fix the loose parts.
Baumholder 13 Doors, Automatic Entrance and Exit BAU000013 - BAU000018 UVV TEST AUTOMATED DOORS (6)
Baumholder 13 Doors, Automatic Entrance and Exit Doesn 't run
Baumholder 13 Doors, Automatic Entrance and Exit DONT CLOSE
Baumholder 6 Alarm System, Intrusion (IDS) work Order includes the invoice for the Schranner company for monthly maintenance on the sprinkler system. work Order was opened by Nikolaos Kastrinos from wISAG.
Baumholder 6 Alarm System, Intrusion (IDS) CHANGE ACCUS
Baumholder 6 Alarm System, Intrusion (IDS) ACCU NEEDS TO BE CHANGED
Baumholder 6 Alarm System, Intrusion (IDS) ALARM SwITCH NOT CONNECTED
Ramstein AB 747 Fire Protection Door Door Inoperative
Ramstein AB 903 Plumbing and Fixtures Both warehouse men 's bathroom urinals clogged
Ramstein AB 802 Oven, Baking and Roasting Heating is inconsistent in the unit
Ramstein AB 1039 Forklift Right hand upper reverse light broken
Ramstein AB 990 Pallet Jack, Electric Brakes will not disengage.
Ramstein AB 903 Plumbing and Fixtures Customer side female handicap door stuck.
Ramstein AB 602 Doors, Automatic Entrance and Exit Doors Inoperable, but can be manually opened (Compromising security)
Ramstein AB 907 Doors and Windows CMPP-2 Door off its railing, can not get into the walk-in area.
Ramstein AB 903 Plumbing and Fixtures Men Customer Restroom Urinal is inoperable, requires maintenance.
Ramstein AB 910 Lighting, Sales Area Two lights above the sinks in Male Customer bathroom are out and requires replacement.
Ramstein AB 864 Emergency Light, Central w/Battery Control NOT Exit lights
Emergency lighting system - system relay is in operable - several areas of the store in darkness - requires immediate maintenance - High Safety concern
Ramstein AB 907 Doors and Windows
Heating Utility room door (next to bottom floor fire suppression room) actuator broken, requires maintenance.
Ramstein AB 920
Disposal, Hazardous Waste and Accountable Equipment
(requires DeCAF 40-108)
Coffin freezer (RAM001097) beyond repair, requires disposal due to hazardous material.
Ramstein AB 602 Doors, Automatic Entrance and Exit Sliding Door does not open or close automatically - requires immediate maintenance
Ramstein AB 908 Electrical System wiring cables have disconnected in warehouse at the ceiling level - hinders placement of pallets in top level
Ramstein AB 482 Cabinet, Food Warming Food warmer heating element burned out and requires a new heating element
Ramstein AB 904 Roofing Roof leak in Hallway outside of the Accounting office.
Ramstein AB 903 Plumbing and Fixtures
Produce Department - sink draining right on to the floor - requires immediate maintenance - Poses safety hazard
Ramstein AB 486 Scale and Scale Labeler
Includes the invoice from the Boss Scale Center for the maintenance of the scales as discussed over the
Ramstein AB 1019 Pallet Jack, Electric
Includes the invoice from Still for the maintenance of the Pallet Jacks as discussed over the phone with Mr.
Groh. This work order was opened by Nikolaos Kastrinos from wISAG.
Ramstein AB 1085 Forklift
Includes the invoice from Still for the maintenance of the forklifts as discussed over the phone with Mr.
Ramstein AB 1084 Pallet Jack, Electric
Includes the invoice from Still for the maintenance of the Pallet Jacks as discussed over the phone with Mr.
Industrial Electrical cable needed for back up freezer - currently not operational with out - requires replacement cable immediately
Boiler circulation pump and heating system separator valve are broken and require immediate maintenance
Ramstein AB 705 Display, Self Contained (Stand Alone Display)
Display broken - no airflow and temperature rising - does not go into defrost mode - requires immediate
Ramstein AB 747 Fire Protection Door Door not opening - malfunctioning and requires servicing
Ramstein AB 606 Doors, Automatic Entrance and Exit
Sliding door glass is broken - customer ran into door and door glass is shattered now - poses safety hazard
Ramstein AB 1083 Pallet Jack, Electric Pallet jack broken - there is a bump in the drive wheel - requires servicing
Attachment 2: Sample Work Orders: Past 2 YearsAttachment 2: Sample Work Orders: Past 2 Years
Ramstein AB 803 Oven, Baking and Roasting
Oven is not able to be programed - time and temperature is not able to be adjusted - requires immediate service
Ramstein AB 1044 Pallet Jack, High Lift Electric Pallet jack wheel broken - requires replacement
Ramstein AB 1042 Pallet Jack, High Lift Electric Pallet jack does not hold charge
Ramstein AB 1084 Pallet Jack, Electric Pallet jack does not lift
Ramstein AB 987 Pallet Jack, Electric Pallet jack does not hold a charge
Ramstein AB 988 Pallet Jack, Electric Pallet jack does not hold charge
Ramstein AB 991 Pallet Jack, Electric Pallet Jack does not engage into drive
Ramstein AB 903 Plumbing and Fixtures women 's customer restroom - toilet continues to run and will not shut off
Ramstein AB 757 Fire Protection Door ''Cool-It'' sensor requires to be serviced and inspected - having issues with door not closing.
Ramstein AB 748 Fire Protection Door ''Cool-It'' sensor requires to be serviced and inspected - having issues with door not closing.
Ramstein AB 766 Fire Protection Door ''Cool-It'' sensor requires to be serviced and inspected - having issues with door not closing.
Ramstein AB 761 Fire Protection Door ''Cool-It'' sensor requires to be serviced and inspected - having issues with door not closing.
Ramstein AB 747 Fire Protection Door ''Cool-It'' sensor requires to be serviced and inspected - having issues with door not closing.
Ramstein AB 911 Lighting, Warehouse H/B room has two light bulbs out and requires to be replaced.
Ramstein AB 931 Pallet Jack, High Lift Electric Pallet jack handle is broke off at the base - requires service and repair
Ramstein AB 1078 Slicer (Bread, Deli, Bistro) Slicer - feeder chain and separator not functioning properly - requires service
Ramstein AB 1029 Scale and Scale Labeler
Scale - touch screen will not calibrate and features of the scale are not accessible. - must be serviced.
Ramstein AB 601 Auto Door Armored (Grafenwoehr, Ansbach, Ramstein)
Front Exterior Door - doors continuously keep jumping off the track and does not close or open - every day it jumps off the track and everyday the door requires it to be put back on track - requires immediate
Men 's customer Restroom - urinal is continuously backing up/ not flushing - needs immediate maintenance
Ramstein AB 1025 Scale and Scale Labeler Scale does not turn on or operate at all - requires full service
Ramstein AB 907 Doors and Windows Replacement master key card is needed tn order to make copies of all keys in the facility
Ramstein AB 602 Doors, Automatic Entrance and Exit Sliding doors are inoperable and not opening or closing
Sliding doors are inoperable and not opening or closing
Ramstein AB 1031 Baler Baler is not operable
Ramstein AB 952 Fire Protection and Flue Flap (per store x # of flaps) Flue Flap motor burned out and not operable
Ramstein AB 903 Plumbing and Fixtures Men 's customer restroom - urinal overflows
Ramstein AB 1008 Heating System (Grafenwoehr, Ansbach, Ramstein) Heating system - Loss of hot water - not holding temperature - immediate attention is needed
Ramstein AB 851 Ventilation System (stores after 2007) Ventilation system humidity control is not operable.
Ramstein AB 850 Ventilation System (stores after 2007) Ventilation system humidity control is not operable.
Ramstein AB 802 Oven, Baking and Roasting Deli/Bakery Oven leaking water
Admin Office 15 D door is in the locked position and the handle is broken - required immediate maintenance;.
Ramstein AB 92521 PM Bulk Upload (T&M) DEC 22 Experiencing issues with steering the store 's Scissor Lift. Request inspection to resolve issue.
Ramstein AB 902 Gutters and Downspouts Downspout clogged with debris. Downspout clogged located on right side of store entrance.
Ramstein AB 6 Ceilings
Roof leak in administrative area on second floor near MSC office. water leaking from celling/lighting fixture and poses safety hazard.
Ramstein AB 797
Doors, Motor Driven & Manual (Warehouse, Sectional, Rollup or Sliding)
Door is unable to be secured - requires lock to be replaced - poses security issue
Ramstein AB 796
Door is unable to be secured - requires lock to be replaced - poses security issue
Ramstein AB 903 Plumbing and Fixtures washing machine requires to be hooked up to water line
Ramstein AB 907 Doors and Windows Admin door - closure cylinder broken - requires replacement.
Ramstein AB 910 Lighting, Sales Area Spot lights in the rear of the store required to be replaced.
Ramstein AB 910 Lighting, Sales Area Deli/ Bakery - 5 Fly lights burned out - requires replacement bulbs
Cash cage door locks are not operating appropriately. Poses risk to key to break off inside lock mechanism.
Ramstein AB 1039 Forklift
Forklift ignition broken - lock cylinder broken and is operational without key - poses safety and security risk
Ramstein AB 606 Doors, Automatic Entrance and Exit Sliding door not operable - tried to reset and does not function at all - requires maintenance
Ramstein AB 747 Fire Protection Door Chill fire door roller broken does not open or close correctly - requires maintenance
Ramstein AB 917 Kitchen Unit (including Appliances)
Deli/ Bakery - multiple cabinet doors are damaged and do not shut securely - poses a safety issue
Ramstein AB 897 Personnel Safety Alarm, Restroom LDS is down -Enkelmann is not able to read the system or alarms - requires service
Ramstein AB 873
Ventilation System (without heating or cooling coil), Exhaust Fans
Extremely Humid inside store - Condensation on all displays - requires service
Lower humidity
Ramstein AB 761 Fire Protection Door
Produce chill door missing sections of seals on door - requires seals to be replaced and door readjusted
Ramstein AB 726 Alarm System, Fire w/Tableau Fire alarm system panel - error notification
Ramstein AB 906 Walls External wall at entrance requires approx. 12 hooks to be installed for hanging of flag
Front sliding door - Locking mechanism is broken and requires repair.
Dry Goods loading dock roll up door was damaged by forklift - requires immediate maintenance.
Ramstein AB 911 Lighting, Warehouse Produce chill room has 26 light bulbs burned out - requires replacement
Ramstein AB 911 Lighting, Warehouse Deli/ Bakery has 6 light bulbs burned out - requires replacement
Ramstein AB 911 Lighting, Warehouse Meat room has 2 light bulbs burned out -requires replacement
Ramstein AB 911 Lighting, Warehouse Chill room has 8 light bulbs burned out - requires replacement.
Ramstein AB 911 Lighting, Warehouse Back hallway have 24 light bulbs burned out - requires replacement.
Ramstein AB 912 Lighting, Interior (offices, bathrooms & technical rooms)
Office light bulbs require replacement:
Room 17 has 2 bulbs burned out
Room 23 has 2 bulbs burned out
Room 35 has 2 bulbs burned out
Room 84 has 2 bulbs burned out
Ramstein AB 910 Lighting, Sales Area Sales floor area has- 80 light bulbs burned our - requires replacement
Ramstein AB 1177 Display, Self Contained (Stand Alone Display) D/B display freezer is not holding temperature
Ramstein AB 1021 Scale and Scale Labeler Deli/ Bakery scale is not turning on for operation.
Produce Table - wood is broken and screws ripped out table - requires maintenance to replace wood section to hold a weight of produce.
Ramstein AB 757 Fire Protection Door Fire door track wheel is broken - requires immediate repair - further damage may occur
Ramstein AB 1040 Forklift Forklift requires all tires replaced - has no tread and posses a safety hazard.
Drainage - strong odors are coming from drainage and is noticed through out the store and warehouse - a complete flushing of the drainage is requested
Ramstein AB 705 Display, Self Contained (Stand Alone Display) Display G&G - currently not operable and runs at high temperatures
Mass display area - windows require one way mirror film tint where you can look out but cannot look in.
Swinging door in the rear of the store by the discount section has a broken hinge - requires maintenance
Ramstein AB 990 Pallet Jack, Electric Pallet Jack - Not holding charge - does not operate
Ramstein AB 907 Doors and Windows handle and lock need repaired in women 's patron handicap restroom
Ramstein AB 766 Fire Protection Door Fan is leaking in meat cooler - RAM 000766
Two electric pallet jack require disposal - contains hazardous materials (Batter cells, hydrolic fluid, oil and grease)
Ramstein AB 930 Warm Air Blower Requires filters for maintenance
Ramstein AB 929 Warm Air Blower Requires filters for maintenance
Ramstein AB 927 Warm Air Blower Requires filters for maintenance
Ramstein AB 928 Warm Air Blower Requires filters for maintenance
Ramstein AB 951 Warm Air Blower Requires filters for maintenance
Ramstein AB 926 Warm Air Blower Requires filters for maintenance
Ramstein AB 950 Warm Air Blower Requires filters for maintenance
Ramstein AB 948 Warm Air Blower Requires filters for maintenance
Ramstein AB 949 Warm Air Blower Requires filters for maintenance
Ramstein AB 877 Ventilation System (stores after 2007) Requires filters for maintenance
Ramstein AB 878 Ventilation System (stores after 2007) Requires filters for maintenance
Ramstein AB 852 Ventilation System (stores after 2007) Requires filters for maintenance
Ramstein AB 850 Ventilation System (stores after 2007) Requires filters for maintenance
Ramstein AB 851 Ventilation System (stores after 2007) Requires filters for maintenance
Ramstein AB 862 Water Treatment System (building water supply) water treatment system requires Filters for maintenance.
Ramstein AB 605 Auto Door Armored (Grafenwoehr, Ansbach, Ramstein)
External Door - not operational - will not open or close on it 's own.
Men 's customer restroom - Toilet and urinal are leaking or overflowing on to the floor again - requires a more thorough maintenance - issues with the drainage continue to be a problem
Ramstein AB 842 Water Treatment System (building water supply) water system requires filter change and cleaning
Ramstein AB 805 Oven, Proofer Bakery Proofer (DE0115825) is leaking water causing safety hazard.
Ramstein AB 900 Flooring warehouse bathroom area - Tiles are broken and require to be repaired - Tripping hazard
Produce department table - end came off and requires repair - Hold produce from falling on to the floor
Men 's customer Restroom - Urinal not draining and is leaking on the floor - Continuous issue may require the drainage to be flushed from toilets, sinks and urinals
Produce dept. swinging doors need to be swapped out for the internal swinging doors to allow free flow of traffic with product - poses a safety concern
Front exterior sliding glass doors require to be serviced - Doors do not open or close and pose a security/ safety hazard
Ramstein AB 818 Slicer (Bread, Deli, Bistro)
Deli/Bakery slicer requires blade to be replaced and serviced - Blade in condition that may pose safety hazard
Ramstein AB 903 Plumbing and Fixtures Drain in warehouse backing up and strong odorous gasses are being released
Ramstein AB 482 Cabinet, Food Warming Food warming Cabinet - inoperable- does not heat and the wheels are broken
Ramstein AB 902 Gutters and Downspouts Downspouts are not draining properly around the whole building - requires to be flushed out
Ramstein AB 1039 Forklift Forklift requires battery to be serviced
External Sliding door - requires immediate maintenance - motor burned out
Ramstein AB 1020 Pallet Jack, Electric Pallet jack requires maintenance - does not engage to drive
Ramstein AB 922 Loading Area Surfaces (sole DeCA use locations only)
Loading area requires signage post to be repaired.
Front Sliding doors are not operational - poses a security issue
Ramstein AB 917 Kitchen Unit (including Appliances) Kitchen unit - brackets broken and require replacement
Ramstein AB 903 Plumbing and Fixtures Men 's customer restroom - urinal is backed up and not draining
Ramstein AB 903 Plumbing and Fixtures Men 's customer restroom - Sink not draining
Ramstein AB 705 Display, Self Contained (Stand Alone Display) Display does not cycle air and is not cooling
Ramstein AB 917 Kitchen Unit (including Appliances) Freezer unit is noisy and the temperature fluctuates in a short period of time
Ramstein AB 906 Walls
Men 's customer restroom utility access panel broken and requires secured and a lock put in place
Loading ramp broken and in the down position - requires repair
Ramstein AB 713 Baler Compactor/ Baler is broken - Door is missing a part and does not stay secure - Safety hazard
Ramstein AB 901 Gates and Fences
Back lot gate broken- is not secured and is held close with pallets- Gate and lock need to be repaired
Ramstein AB 903 Plumbing and Fixtures Men 's customer bathroom - Toilet clogged and overflowing
Ramstein AB 1008 Heating System (Grafenwoehr, Ansbach, Ramstein) Heating System - Lost hot water throughout the building
Ramstein AB 909 Lighting, Outside
Illuminated Sign in front of store requires to be changed to indicate no more Early Bird shopping - Must read:
0730 - 2100 Monday
0730 - 2100 Tuesday
0730 - 2100 wednesday
0730 - 2100 Thursday
0730 - 2100 Friday
0730 - 2100 Saturday
0730 - 2000 Sunday
Ramstein AB 904 Roofing
Emergency work order called in for a leaking roof. water dripping from the roof and puddling on the sales floor in front of the fresh meat department.
Admin to warehouse Hallway - Second set of fire doors do not close in the event of a fire - bottom of door rubs the floor, preventing the closure of the door. Found during yearly fire inspection
Ramstein AB 607 Auto Door Armored (Grafenwoehr, Ansbach, Ramstein)
Exit door in # 2 vestibule requires maintenance - does not open or close - Security and Safety concern.
Ramstein AB 903 Plumbing and Fixtures Deli/ Bakery - 3 basin sink is leaking on the floor and requires maintenance.
Ramstein AB 812 Bakery Cabinet, Self Service Bakery Cabinet requires light to be replaced
Ramstein AB 811 Bakery Cabinet, Self Service Bakery Cabinet requires light to be replaced
Ramstein AB 809 Bakery Cabinet, Self Service Bakery Cabinet requires light to be replaced
Ramstein AB 815 Bakery Cabinet, Self Service Bakery Cabinet requires light to be replaced
Ramstein AB 814 Bakery Cabinet, Self Service Bakery Cabinet requires light to be replaced
Ramstein AB 906 Walls Deli/ Bakery requires two magnetic white boards to be installed
Deli/ bakery requires 14 light bulbs to be replaced
Ramstein AB 757 Fire Protection Door Door requires lock for security
Ramstein AB 761 Fire Protection Door Door requires lock for security
Ramstein AB 908 Electrical System warehouse - Electrical switch is missing switch plate - requires replacement.
Ramstein AB 911 Lighting, Warehouse Meat Department Chill - 3 Bulbs burnt out and requires replacement
Bagger break room - window blinds anchors have fell off of the wall at it 's attachment points. - requires re install
Ramstein AB 1047 Eyewash Station Eye wash station - requires replacement of head and stem
Ramstein AB 1044 Pallet Jack, High Lift Electric Pallet Jack - battery refill nozzle broken - requires replacement
Ramstein AB 903 Plumbing and Fixtures Plumbing leak from water pipe in warehouse
Secured Storage room requires window to be replaced with something that will allow ventilation but also be secured.
Ramstein AB 911 Lighting, Warehouse Deli/ Bakery Chill exit sign requires light to be replaced
Ramstein AB 911 Lighting, Warehouse Chill- 6 each lights are burnt our and require replacement
Ramstein AB 903 Plumbing and Fixtures Deli/ Baker - automatic sink is inoperable and requires maintenance
Ramstein AB 1015 Exhaust Hood w/extingushers (Ansul & similar) Deli/ Bakery Exhaust hoods require filter change and deep cleaning
Ramstein AB 850 Ventilation System (stores after 2007) Sales Floor - Air ducts require filter change and cleaning
Ramstein AB 851 Ventilation System (stores after 2007) Sales Floor - Air ducts require filter change and cleaning
Ramstein AB 1018 Pallet Jack, Electric Pallet Jack - Key lock broken - Can be used unsecured without key
Ramstein AB 1078 Slicer (Bread, Deli, Bistro) Deli/ Bakery meat slicer requires full service- Blade is dull and bent- Possible safety hazard
Ramstein AB 817 Slicer (Bread, Deli, Bistro)
Deli/ Bakery Slicer requires servicing- Blade bent/damaged- transport arm does not transport the product-
May pose safety hazard
Solid/ Permanent conduit drop required for work center set up for operational function in Administrative
Area 15D
Ramstein AB 934 High Pressure Cleaner
High Pressure cleaner requires servicing- Does not operate- Various hoses require replacement- possible battery change
Ramstein AB 1057 High Pressure Cleaner High pressure cleaner requires servicing. Runs for 5 - 10 minutes and then shuts off
Ramstein AB 914 Lighting, Centrally Controlled (DALI, etc.)
update lighting to allow for diming of sales floor lights. work is to be completed with wO 244UM2210541 ( to save sub 's travel cost). This wO will replace previous wOs that have been cancelled.
Ramstein AB 844 Pallet Jack, Manual (PM only) Pallet jack is leaking grease/ oil- Does not lift
Ramstein AB 777
Plastic weather strips must be replaced. Hazed, broken and torn
Unable to operate (open/close) main loading dock door.
Ramstein AB 910 Lighting, Sales Area Lights in entrances/ exits are off at night during open hours and may be on a timer.
Ramstein AB 1082 Pallet Jack, Electric Pallet Jack inoperable- safety switch fell off the equipment
Ramstein AB 1041 Display, Self Contained (Stand Alone Display) Display temperature running high- fans not circulating air
Ramstein AB 996 Handicap Cart Handicap Cart- will not hold a charge- possible battery replacement
Ramstein AB 903 Plumbing and Fixtures Men 's customer restroom- Overflowing and not draining
Ramstein AB 910 Lighting, Sales Area Produce- The entire lighting above the produce sales area is broken and requires repair
Deli/ Bakery-Critical for sanitation- Sensors on sinks has lost power to the fixture for operation- Requires immediate maintenance. Essential for Deli/ Bakery operations
Ramstein AB 705 Display, Self Contained (Stand Alone Display) Display is inoperable- No fan or circulating any air at all.
Ramstein AB 1029 Scale and Scale Labeler Labeler is malfunctioning- Consistently jams and requires to be reset.
Ramstein AB 903 Plumbing and Fixtures Produce- Sink in prep room is leaking from the drainage fixture-Poses slipping hazard
Doors stuck in the open position-Compromises security of the facility.
Ramstein AB 605 Auto Door Armored (Grafenwoehr, Ansbach, Ramstein)
Doors stuck in the open position-Compromises security of the facility.
Ramstein AB 989 Pallet Jack, Electric
Request for cost proposal to fully repair by cannibalizing parts from other inoperable pallet jacks and installing new battery.
Ramstein AB 704 Display, Self Contained (Stand Alone Display) Display is not operable and is circulating room temperature air
Ramstein AB 901 Gates and Fences Railing in front of Deli/Bakery display is broke and requires maintenance.
**EMERGENCY**-power outlet in which Refer Trailer tripped circuit and has no power-Product currently in trailer-Immediate maintenance required
Ramstein AB 981
Generator, Diesel (more than 50kW) (KCS, CMPP & CDG)
Annual
Batteries required to be replaced
(Service is done thru PM)
Ramstein AB 903 Plumbing and Fixtures Mechanical Room Heating system- regulator/splitter is broken and leaking.
In the process of installing a new stand up freezer for the Deli/Bakery, wisag technician has determined that the designated space for the freezer is slightly too small and is requesting for modification of the area in order to allow additional space to complete the install.
Men 's customer restroom urinal is not flushing and has overflowed- Requires immediate attention!
Ramstein AB 481 Cabinet, Food Warming warmer not operational- Does not get hot and maintain hot temperature.
Ramstein AB 989 Pallet Jack, Electric Pallet Jack wheel broken requires repair
Ramstein AB 990 Pallet Jack, Electric Still Pallet Jack handle broken- Awaiting maintenance
Ramstein AB 907 Doors and Windows women 's Customer Restroom Stall door handle fell off and requires maintenance
Ramstein AB 903 Plumbing and Fixtures Emergency- Drainage sink in walk in freezer (RAM000784) is clogged.
Tripping Hazards- Permanent/Solid conduit drops with 4 outlets in 6 different places in the rear of the store.
Ramstein AB 932 Personnel Safety Alarm, Cold rooms (per room)
Personal Safety Alarm malfunction- wires disconnected due to operator unawareness of function of alarm.
Requires wires to be connected again
Freezer Trailer inoperable due to 400v power outlet failure on receiving ramp #5- Requires maintenance immediately
Safety Hazard- Request to install a sliding guard rail system on 5 areas of back receiving docks (mechanical ramp lifts)- Only chains are in place for protecting a fall presently.
These chains, ropes, or straps do not meet OSHA standards and the Ramstein Commissary is not in compliance. OSHA references are attached
Safety hazard- Support bar on cart corrals has separated from the frame in several areas with pose a point in which it may cause impalement or serious injury
Ramstein AB 907 Doors and Windows Security issue- External Sliding Glass doors stuck in the open position.
Ramstein AB 954 Display, Self Contained (Stand Alone Display) Display missing feet at the bottom and the glass door broken
Ramstein AB 1097 Display, Self Contained (Stand Alone Display) Display not maintaining temperature- Fan Broken- Missing Foot on the bottom of display
Security Issue- Door to the outside from the Administrative office does not latch and stays open.
Replaces wO244EM2214829 which is in Error...
Ramstein AB 1039 Forklift
Forklift- Build up of corrosion found all over the top of the battery. Inspection indicates that battery must be replaced- can lead to a fire hazard
Ramstein AB 744 Slicer (Bread, Deli, Bistro) Cheese slicer blade bent and dull- requires servicing and or replacement of blade.
Ramstein AB 991 Pallet Jack, Electric Power Jack requires servicing- does not stay charged or not charging at all
Ramstein AB 1084 Pallet Jack, Electric Power Jack requires servicing- wheel is broken and needs to be replaced
Ramstein AB 1085 Forklift Power Jack key lock broken and must be service for normal operation
Ramstein AB 931 Pallet Jack, High Lift Electric Power Jack is inoperable- must be serviced
Ramstein AB 1081 Scrubbing Machine
Scrubbing Machine squeegee does not properly lower and brush does not spin- Requires servicing
Ramstein AB 1080 Scrubbing Machine
Scrubbing Machine not working properly- has no suction and the brush on one side does not spin
Ramstein AB 1085 Forklift Still fork lift does not charge and/or stay charged- Requires service
Ramstein AB 818 Slicer (Bread, Deli, Bistro) Meat slicer blade bent and dull- requires servicing and or replacement of blade
Ramstein AB 906 Walls wall tile by cash cage entry is separating from off the wall- being held up by clear packing tape
Ramstein AB 1096 Grill, Rotary Electric (Rotisserie) Rotisserie Grill requires new heating lights that are needed in order to properly cook
Ramstein AB 1095 Grill, Rotary Electric (Rotisserie) Rotisserie Grill requires new heating lights that are needed in order to properly cook
Ramstein AB 710 Mobile Work Platform (Scissors lift & similar) Skyjack not operable: maintenance is required: Inspection and service is needed
Ramstein AB 903 Plumbing and Fixtures Men 's customer Restroom- urinal not draining and overflowing
Ramstein AB 1031 Baler
Safety Hazard- Baler is stuck half way-cannot close for safety precautions- Maintenance required
Security Issue- Door stays in the open position and does not close
Request for disposal and hazardous materials on RAM000764
Ramstein AB 906 Walls TV mount requires installation in Administrative Area 15D
Ramstein AB 835 Dispensers, Various Emergency- Customer water fountain does not drain and overflows
Loading dock ramp inoperable-Does not adjust correctly and leave open area for rodents to enter the facility
Ramstein AB 908 Electrical System Electrical outlet on isle #7 is broken and requires maintennce
Ramstein AB 904 Roofing Roof leaking over sales area-requires immediate maintenance
Ramstein AB 748 Fire Protection Door walk in Freezer Door is seeping condensation on external parts of door- Door requires seals to be replaced
Security issue- Doors in the locked position and cannot be reset.
Ramstein AB 1079 Fire Extinguishers (portable & wheeled, DeCA owned only)
Fire extinguishers reached shelf life and requires to be replaced throughout the store.
Ramstein AB 705 Display, Self Contained (Stand Alone Display) Display lost power and is warm
Men 's customer restroom- requires 3 lights replaced and 2 lights over the sinks to be replaced
Ramstein AB 708 Display, Self Contained (Stand Alone Display) Display leaking refrigerant
Ramstein AB 1059 Baler
Cardboard compacter/ bailor- malfunctions and makes banging noise- Control panel has fell off and taped back on. Cannot utilize control panel.
Ramstein AB 911 Lighting, Warehouse Loading dock- 7 extended spot lights needs bulbs replaced
Ramstein AB 907 Doors and Windows Bakery/ Deli swinging Door- Broken- door broke off its hinges
Ramstein AB 900 Flooring
Safety Hazard- Floor tiles broken and missing pieces- Deep!
NO NIGHT wORK AUTHOIZED
Ramstein AB 747 Fire Protection Door Chill sliding door gasket torn- Needs repaired
Ramstein AB 991 Pallet Jack, Electric Pallet Jack inoperable- charger is not charging the battery
Ramstein AB 903 Plumbing and Fixtures Men 's warehouse restroom stall door handle broken- needs repaired
Ramstein AB 903 Plumbing and Fixtures Produce Department faucet is loose/ broken- leaks and sprays out when turned on
Ramstein AB 741 Fire Protection Door Fire and Smoke detection Inspection findings- Requires servicing- See attached
Produce Department Fruit cooler - Outside perimeter of room has deep crack in the floor at the base of the wall. water seeps into crack from cleaning. fill crack with epoxy or simular
Deli/ Bakery office area requires 3 Lights replaced
Administrative office requires 2 lights replaced
Admin/ Scanning room requires 1 light bulb replaced
Admin hallway requires 4 light bulbs replaced
Training room requires 1 bulb replaced.
Admin to warehouse hallway requires 1 light bulb replaced
Receiving Office requires 1 light bulb replaced warehouse bathroom entrance requires 4 light bulbs replaced
Grocery Manager Office requires 7 light bulbs replaced.
Vendors Room requires 3 light bulbs replaced
Salvage Room requires 6 light bulbs replaced women 's warehouse restroom requires 6 light bulbs replaced.
Produce Department coolers requires 5 light bulbs replaced
Men 's warehouse Restroom requires 9 light bulbs replaced
Ramstein AB 910 Lighting, Sales Area Produce department requires 5 spot light bulbs replaced
Ramstein AB 910 Lighting, Sales Area Bakery requires 1 spot light bulb replaced
Main entrance requires 2 light bulbs replaced
Middle Customer Exit requires 5 light bulbs replaced
Far Customer exit requires 8 light bulbs replaced.
women 's Customer Restroom requires 2 light bulbs above the sinks replaced
Back Hallway walk-in freezer requires 6 bulbs replaced
Back Hallway requires 6 Bulbs replaced
Meat Department Cooler requires 1 bulb replaced
Managers Office requires 2 light bulbs replaced
Grocery Manager Office requires 2 light bulbs replaced
Customer Service Manager Office requires 1 light bulb to be replaced.
Cash Cage requires 5 light bulbs replaced
Customer women 's Bathroom has 2 sinks inoperable. The center and the right sink not draining properly.
Ramstein AB 1097 Display, Self Contained (Stand Alone Display) Chest freezer has LED light broken
Ramstein AB 1094 Display, Self Contained (Stand Alone Display) LED light broken in side chest freezer
Ramstein AB 796
Loading dock door #2 and outer skirt damaged by truck. Must be repaired.
install sweepers or add additional material to door bottoms to prevent rodents from getting into the building
NOT AN EMERGENCY, process as UM only, work only authorized on exterior doors. No work authorized on interior doors
No work authorized on roll up doors: stores must submit UM wO under the individual inventory numbers
Ramstein AB 1013 Grease/Oil and Gas Separators and Sludge Traps
Grease trap alarm must be serviced. grease trap is located outside in the back of the produce department.
Ramstein AB 910 Lighting, Sales Area 48 light fixtures on store sales floor need bulbs replaced.
Ramstein AB 903 Plumbing and Fixtures Center sink in Men 's warehouse restroom does not drain.
Ramstein AB 903 Plumbing and Fixtures Free standing urinal in men 's warehouse restroom is over flowing.
Ramstein AB 903 Plumbing and Fixtures Men 's warehouse restroom toilet seat in 1st stall on the right hand side- toilet seat is loose.
Ramstein AB 903 Plumbing and Fixtures urinal in men 's warehouse restroom (handicap stall) is overflowing.
Ramstein AB 907 Doors and Windows External HVAC Room Door 31P drags on floor when opening.
Ramstein AB 1040 Forklift Driver door does not latch closed.
Ramstein AB 903 Plumbing and Fixtures Repair water hoses located by produce receiving door and meat department.
Ramstein AB 792
Receiving Roll-up door cable defective. Door inoperable.
Ramstein AB 1084 Pallet Jack, Electric Rubber wheel on fork worn off
Ramstein AB 907 Doors and Windows Doorbell located at receiving bay 4 (chill roll-up door) non-operational.
Ramstein AB 706 Display, Self Contained (Stand Alone Display) Dispose of inoperable/unpreparable display cooler.
Ramstein AB 736 Display, Self Contained (Stand Alone Display) Dispose of inoperable/unpreparable display freezer.
Ramstein AB 906 Walls Mount 3 each whiteboards (3 meter long) on Grocer Department Office walls.
Ramstein AB 746 Fire Protection Door walk-in Cooler door electrical cable replacement required.
Ramstein AB 1059 Baler Baler hydraulic fluid low.
Ramstein AB 909 Lighting, Outside
Safety Issue - Lighting located outside of warehouse receiving doors by the ramp is not functioning.
Ramstein AB 1098 Ice Maker
Ice Machine leaking around drainage plug causing pooling water in prep-room. wisag quick fixed it last year, but plug needs replacing.
Ramstein AB 851 Ventilation System (stores after 2007) Humidity control not working. High store temp.
Ramstein AB 914 Lighting, Centrally Controlled…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .