Informational_Only_2_-_Supervisor's_Office_Asb_Insp_Rpt.Final.pdf

PDF 2 MB Posted

Attached to
Bridger-Teton NF Supervisors/Jackson Ranger District Office Construction Project Federal contract opportunity
Solicitation number
AG-02NV-S-15-0024
Issued by
Department of Agriculture Forest Service R4-Intermountain Region

About this file

Info Only 2 - SO Asbestos Inspec Report

View the file

Other files for this federal contract opportunity

Other files attached to Bridger-Teton NF Supervisors/Jackson Ranger District Office Construction Project, newest first.
File Type Posted
Amend_0003-_AG-02NV-S-15-0024.pdf PDF
ATT_1_-_Amendment_3_-_Revised_ATT_9___B-T_Cost_Estimate_Breakdown.xlsx XLSX spreadsheet
ATT_2_-_Revised_Schedule_of_Items.pdf PDF
Amend_0002_-_AG-02NV-S-15-0024.pdf PDF
ATT_4_-_Revised_HVAC_Controls_and_Equipment_Drawings.pdf PDF
ATT_3_-_Revised_Drawings.pdf PDF
ATT_1_-_Correction_to_Amend_0001_-_AG-02NV-S-15-0024.pdf PDF
ATT_2_-PFC_Pre-Functional_Test_Log_B-T_Supervisr's_office_Jackson_Ranger_Dist-U....pdf PDF
ATT_3_-_5-7-15_Prebid_Conference_Attendees_List.pdf PDF
ATT_1_-_JacksonSOSheet5FoundationPlan.pdf PDF
Amend_001_-_AG-02NV-S-15-0024.pdf PDF
Informational_Only_5_-_Green.Globes.StrategyBridger-Teton_Supervisor_ _Jackson_Ranger_District_Office_4.10.15.pdf PDF
Informational_Only_3_-_Engineer's_Garage_Asb_Insp_Rpt.Final.pdf PDF
ATT_9_-__B-T_Supervisor-District_Ranger_Office_Building_Construction_Cost_Estimate_Breakdown.xlsx XLSX spreadsheet
ATT_5_-_Geotechnical_Report_-_Final_BTSO_Geotech_Report.pdf PDF
Informational_Only_1_-_Climate.Data.31.2014.pdf PDF
ATT_7_-_WD_-_WY17__-01-02-15.pdf PDF
ATT_8_-_Past_Performance_Questionnaire.pdf PDF
ATT_4_-_Functional_Comissioning_Reports_-_Combined_Files_PDF_Pre_Function_03-30-15.pdf PDF
ATT_1_-_Bridger-Teton.SO_SpecsFinal.pdf PDF
ATT_2_-_JACKSON.DRAWINGS.FINAL.4.5.2015.signed.pdf PDF
AG-02NV-S-15-0024_Jackson_SO_Office_Construction_Solicitation.pdf PDF
ATT_6_-_Geothermal_Boring_Soils_Report_-_232113.33_Attachment_Jackson_FS_Full_TC_Report_-spec.pdf PDF
Informational_Only_4_-_VIC_Asb_Insp_Rpt.Final.pdf PDF
ATT_3_-_Commissioning_Plan_-__Cx_Plan-final_20150330.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

640 EAST WILMINGTON AVE SALT LAKE CITY UT 84106 TELEPHONE: 801-466-2223 FAX: 801-466-9616 E-MAIL: IHI@IHI-ENV.COM

SALT LAKE CITY SAN FRANCISCO PHOENIX DENVER SEATTLE

PRE-DEMOLITION INSPECTION FOR ASBESTOS AND

UNIVERSAL, HAZARDOUS, AND TOXIC WASTES

USDA Forest Service

Bridger-Teton National Forest Compound Jackson, Wyoming

Building TN80101 Supervisor’s Office

September 5, 2014

Prepared for:

Mr. Kevin Lewis, Project Manager Case, Lowe & Hart, Inc.

2484 Washington Boulevard Ogden, Utah 84401

Prepared by: Reviewed by:

John C. Larson, Utah State Certification No. ASB-0894

AHERA Certification No. 130712

Jon H. Self Asbestos Program Manager

State of Utah Company Certification No. 22

IHI Project No. AL147459E

USDA FS/Supervisor’s Office Table of Contents IHI Environmental Asbestos Inspection Project No. AL147459E

TABLE OF CONTENTS

EXECUTIVE SUMMARY

1.0 INTRODUCTION

1.1 Facility Description

1.2 Scope of Work

2.0 METHODOLOGY

2.1 Bulk Sample Collection

2.2 Bulk Sample Analysis

2.3 Bulk Sample Results

3.0 CONCLUSIONS AND DISCUSSION

3.1 Regulatory Guidance

3.2 Inaccessible Areas/Materials

4.0 PROJECT LIMITATIONS

TABLES

Table 1: Material Inspection Summary Table 2: Asbestos Material Disposition Summary

APPENDICES

Appendix A: Laboratory Analytical Reports Appendix B: Photographic Log of Materials Sampled Appendix C: Asbestos Sampling Locations (Drawing) Appendix D: Universal, Hazardous, and Toxic Wastes Inspection Appendix E: Inspector Certifications

USDA FS/Supervisor’s Office Executive Summary IHI Environmental

EXECUTIVE SUMMARY

On August 7 and 8, 2014, IHI Environmental conducted a pre-demolition inspection of the

Supervisor’s Office building located at the USDA Forest Service, Bridger Teton National

Forest Compound, Jackson, Wyoming. Mr. Kevin Lewis, Project Manager for Case, Lowe and Hart, Inc., requested this inspection to identify asbestos-containing material (ACM) and

Universal, Hazardous, and Toxic Wastes materials that need to be addressed before the building is demolished or renovated. The following ACMs and Universal, Hazardous, and

Toxic Wastes materials were identified during this inspection and assessment.

ACM

Gypsum board wall system (~18,635 square feet)

Floor tile and mastic (~8,170 square feet)

Duct tape (~6 linear feet)

Light fixture wire insulation (6 units)

Roofing tar sealant (~6 linear feet)

Pipe fitting insulation (~60 units)

Universal, Hazardous, and Toxic Wastes

Mercury-vapor fluorescent light tubes (870 – 4-foot)

Ballasts containing PCBs (435)

Mercury-vapor fluorescent light bulbs (2)

CFC-containing refrigeration units (22)

Containers of liquid waste (TBD)

Table 1 in this Asbestos Inspection and Assessment Report contains detailed information about the ACM, and Section 2 (Findings) in the Universal, Hazardous, and Toxic Waste

Inspection Report contains detailed information about the Universal, Hazardous, and Toxic

Wastes.

USDA FS/Supervisor’s Office Executive Summary IHI Environmental

CONCLUSIONS

ACM – IHI recommends that a Wyoming-certified asbestos abatement contractor remove and properly dispose of all the ACM in this building prior to demolition or renovation.

Universal, Hazardous, and Toxic Wastes – Protocols for identification and disposal of hazardous materials have been developed by the Salt Lake County Health Department

(SLCHD). These protocols require building owners to identify and remove all Universal, Hazardous, and/or Toxic Wastes from buildings before they are demolished in the County of

Salt Lake. Disposition of these materials must follow EPA Guidance outlined in 40 CFR 273

(Standards for Universal Waste Management) and 40 CFR 261 and 262 (Resource

Conservation and Recovery Act), and Department of Transportation regulations outlined at

49 CFR 173 (Shippers - General Requirements for Shipments and Packaging). Using the same guidelines as the SLCHD sets forth in Utah, IHI recommends that the materials identified during this inspection be removed and disposed of by properly trained and licensed contractors.

COST ESTIMATES

IHI’s cost estimates to remove the ACM and remaining hazardous materials outlined above are:

ACM: $71,045

Hazardous Materials: $8,575

These estimates do not include the costs for asbestos abatement design and management consulting services.

The report that follows this Executive Summary should be read in its entirety because it includes important information, such as material descriptions and locations, regulatory requirements and building specific recommended response actions.

USDA FS/Supervisor’s Office 1 IHI Environmental

1.0 INTRODUCTION

On August 7 and 8, 2014, IHI Environmental conducted a pre-demolition inspection of the

Supervisor’s Office building located at the USDA Forest Service, Bridger Teton National

Forest Compound, Jackson, Wyoming. Bulk samples of suspect asbestos-containing material were collected by Mr. John Larson (State of Utah, Asbestos Inspector Certification Number

ASB-0894) (AHERA Certification Number 130712). The State of Wyoming has a reciprocal agreement with the State of Utah and honors the same requirements for certification.

1.1 Facility Description

The building is a two-level structure on a concrete slab. Building size is approximately

10,080 square feet. Construction date is 1964. The construction is wood frame and structural steel, with wood siding. Interior finishes are gypsum board walls and ceilings, with partial wood paneling. Ceilings are suspended 2’ x 2’ panels. Floors are finished with

9” floor tile under glued-down carpet. The ground level has a concrete substrate, and the second level has a wood substrate. The restrooms have ceramic tile. The west center roof area has wood shingles on a pitched wood substrate with a felt underlayment. The flat roof area has asphalt roof sheeting on a wood substrate. The building’s heating system is a hot water boiler, piped to wall-mounted radiators. The cooling system consists of window and/or wall-mounted refrigeration units.

1.2 Scope of Work

The objective of this inspection was to locate, identify, quantify, and document the accessible suspect ACM, universal, hazardous and toxic wastes, and to provide a cost estimate for proper removal. The inspection was limited to accessible surfaces, structures, and mechanical systems with minor destructive sampling of wall cavities.

ACM is any material containing more than one percent asbestos, as determined by polarized light microscopy (PLM).

2.0 METHODOLOGY

Suspected ACM was identified and characterized in terms of homogeneous areas. A homogeneous area is defined as a single material, uniform in texture and appearance, USDA FS/Supervisor’s Office 2 IHI Environmental installed at one time, and unlikely to consist of more than one type or formulation of material.

All suspect ACM was touched to determine its friability. Friable ACM, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

The inspector photographed each homogeneous area sampled. Photographs are included in

Appendix B of this report.

2.1 Bulk Sample Collection

Bulk samples were collected from accessible homogeneous areas of suspected ACM for subsequent laboratory analysis to determine actual asbestos content. Sampling was generally conducted in a manner that minimized damage and unsightly marks in the building and did not create a health hazard for building occupants or inspectors.

The number of samples collected from each homogeneous area generally followed the

Environmental Protection Agency (EPA) Asbestos Hazard Emergency Response Act

(AHERA) regulations (see 40 CFR part 763, subpart E), and the Wyoming Department of

Environmental Quality regulations, which generally follow the AHERA guidelines.

Although AHERA regulations do not apply to this property, the AHERA regulations provide the most comprehensive and acceptable guidance for conducting field inspections for ACM.

The AHERA regulations require the inspector to collect between three and seven samples of surfacing materials, depending on the size of the homogeneous area. Likewise, inspectors collect enough samples of thermal system insulation and miscellaneous materials to confidently characterize the material’s composition.

2.2 Bulk Sample Analysis

All bulk samples were analyzed by EMLab P&K, in Phoenix, AZ, using PLM in accordance with the EPA Method for the Determination of Asbestos in Bulk Building Materials (EPA-

600/R-93-116). EMLab P&K is accredited by the National Institute of Standards and

Technology (NIST) under the National Voluntary Laboratory Accreditation Program

(NVLAP).

USDA FS/Supervisor’s Office 3 IHI Environmental

2.3 Bulk Sample Results

Table 1 identifies all material sample numbers and locations, the homogeneous area number and description, and the quantity of the material. Appendix A includes the analytical reports provided by the laboratory. Appendix B contains photographs of each homogeneous area of suspect ACM identified during this inspection.

3.0 CONCLUSIONS AND DISCUSSION

The materials identified in Table 2 contain asbestos. As such, disturbance of these materials in Wyoming is regulated by EPA, Wyoming Department of Environmental Quality, and/or

OSHA and must be removed by a Wyoming-certified asbestos abatement contractor prior to the start of any renovation or demolition activities that will disturb them. Table 2 includes the recommended response action.

3.1 Regulatory Guidance

The Environmental Protection Agency, Occupational Safety and Health Administration, and the Wyoming Department of Environmental Quality regulations define ACM as a material containing more than one percent of asbestos, as determined by PLM. All three agencies regulate ACM in Wyoming, but only if the material contains more than 1 percent asbestos. If a material contains less than 1 percent, the EPA does not regulate removal or disposal.

However, activities involving materials containing less than 1 percent asbestos are regulated by OSHA.

The OSHA construction regulation pertaining to asbestos (29 CFR 1926.1101) indicates that any asbestos work – including work with materials containing between zero and 1 percent asbestos – that has the potential of producing airborne concentrations of asbestos that exceed the permissible exposure limit (PEL) must be performed applying specific precautions outlined in the regulation.

3.2 Inaccessible Areas/Materials

Heating system pipe fitting insulation, homogeneous area T001. The pipe runs for this material are located in the ceiling space on Level 1 and in wall cavities. There may be additional insulated fittings within the wall cavities and the ceiling space that were not accessible for inspection.

USDA FS/Supervisor’s Office 4 IHI Environmental

Other suspect materials that were hidden or inaccessible may not have been characterized by this inspection. Therefore, any material not identified in this report as having been tested should be treated as suspect ACM until it has been sampled by a Wyoming-certified inspector and analyzed by an accredited laboratory applying EPA methods.

4.0 PROJECT LIMITATIONS

This project was performed using, as a minimum, practices consistent with standards acceptable within the industry at this time, and a level of diligence typically exercised by industrial hygiene consultants performing similar services.

The procedures used in this investigation attempt to establish a balance between the competing goals of limiting investigative and reporting costs and time, and reducing the uncertainty about unknown conditions. Therefore, because the findings of this report were derived from the scope, costs, time, and other limitations, the conclusions should not be construed as a guarantee that all hazardous materials have been identified and fully evaluated. IHI’s professional opinions are based in part on the interpretation of data from discrete sampling locations that may not represent conditions at non-sampled locations. IHI assumes no responsibility for omissions or errors resulting from inaccurate information, or data, provided by sources outside of IHI or from omissions or errors in public records.

Furthermore, it is emphasized that the final decision on how much risk to accept always remains with the client since IHI is not in a position to fully understand all of the client’s needs. Clients with a greater aversion to risk may want to take additional actions while others, with less aversion to risk, may want to take no further action.

Table 1

Material Inspection Summary

Material Sample #

Homogeneous Area Number, Material Description, & Location Lab Result Quantity Sample Location (See Appendix C)

47459E-1

M001: Wall system – gypsum board, tape and joint compound – throughout the building, except the east room

<1% Chrysotile (joint compound)

<0.025% Chrysotile

(composite by point count)

~18,635 square feet

Level 1, boiler room, northwest corner

47459E-2 <1% Chrysotile

(joint compound)

Level 1 utility closet, northeast corner

47459E-3

East stairwell landing, southwest corner

47459E-4

Level 2, copy alcove in hallway, southwest corner

47459E-5 M002: Suspended ceiling panel – 2’ x 2’, fissure and pinhole pattern, flush-mounted – throughout the building except restrooms

None detected

~9,475 square feet

Level 1, data equipment room, above the south doorway

47459E-6 None detected Level 1, room 103, south side

47459E-7 None detected Level 2, hallway by the west stairwell

47459E-8 None detected Level 2, room 208, center

47459E-9 M003: Carpet adhesive – tan and yellow – throughout the building except restrooms, utility closet and the foyer

None detected ~9,190 square feet

Level 1, main lobby, southwest corner

47459E-10 None detected Level 2, west stairwell landing, west side

47459E-11 M004: Vinyl floor sheeting – light tan wood grain pattern – data equipment room None detected ~414 square feet Level 1, data equipment room, south doorway

Material Sample #

Homogeneous Area Number, Material Description, & Location Lab Result Quantity Sample Location (See Appendix C)

47459E-12

M005: Floor tile and mastic – 9” tan with black mastic – throughout the building except restrooms and the data equipment room

<1% Chrysotile (tile)

5% Chrysotile (mastic)

~8,170 square feet

(~20 square feet damaged)

Hallway outside the data equipment room, south doorway, under carpet

47459E-23

<1% Chrysotile (tile)

5% Chrysotile (mastic)

Level 1, utility closet, center

47459E-24 7% Chrysotile (mastic only) Level 1, utility closet, center

47459E-25

<1% Chrysotile (tile)

5% Chrysotile (mastic)

Level 2, hallway fax machine alcove, northwest corner

47459E-13

M006: Roofing – tan asphalt roof sheeting – throughout the roof area, except the center pitched roof section

None detected

~4,690 square feet

Roof east wing, east edge, 5’ north of south corner

47459E-14 None detected Roof south wing, on cricket to the pitched room

47459E-15 None detected Roof south wing, east center

47459E-16 None detected Roof north wing, east center, 10’ west of east edge

47459E-17 M007: Roofing felt – black – under wood shingles on the pitched roof None detected ~700 square feet Center pitched roof, east edge

47459E-18

T001: Pipe fitting insulation – hard white plaster – boiler room and random locations throughout the ceiling space (and possibly wall cavities)

2% Chrysotile <1% Amosite ~51 units Boiler room, 5” fitting above the north end of the boiler

47459E-19 M008: Boiler gasket – white, woven material, 18” diameter – boiler room None detected 1 unit Boiler north end, bottom gasket

47459E-20 M009: Duct tape – tan paper – south end of boiler, around the flue attachment 60% Chrysotile

4 linear feet (2 linear feet of debris) Boiler south end, at the flue attachment

Material Sample #

Homogeneous Area Number, Material Description, & Location Lab Result Quantity Sample Location (See Appendix C)

47459E-21 M010: Ceramic tile thin-set – gray – all restroom floors None detected ~460 square feet Level 1, men’s restroom, east wall, at broken tiles

47459E-22 M011: Ceramic tile adhesive – tan – all restroom walls None detected ~1,345 square feet Level 1, men’s restroom, east wall, at broken tiles

47459E-26 T002: Pipe fitting insulation – hard white plaster – roof drain system

2% Chrysotile <1% Amosite 8 units

Level 2, room 208, southeast corner, above ceiling panels

47459E-27 2% Chrysotile <1% Amosite

Level 2, northwest room, northwest corner, above ceiling panels

None M012: Light fixture wire insulation – 12” round light fixture w/thumb screw – level 2, men’s restroom

Assumed 2 units Not sampled for safety reasons

47459E-28 M013: Exterior caulking – black – around all window units and framing

None detected

~4,250 linear feet

West main entry, northeast corner

47459E-29 None detected South wing, south side, west window unit

47459E-30 None detected North wing, north side, east window unit

47459E-31 M014: Roofing – tar and felt build-up – west main entry canopy

10% Chrysotile (tar sealant)

None detected (tar and felt)

~265 square feet West entry canopy, north side, center

47459E-32 M015: Roofing tar sealant – black, weathered gray – west main entry canopy 10% Chrysotile ~6 linear feet West entry canopy, north side, center

None M016: Light fixture wire insulation – 6” square, recessed, light fixture – west main entry canopy

Assumed 4 units Not sampled for safety reasons

Table 2

Asbestos Material Disposition Summary

Homogeneous Area Number Quantity & Substrate

Assessment Category

& Damage

Disturbance Potential

& Accessibility Recommended

Response Actions Abatement

Cost M001 ~18,635 Sq. Ft. - Framework X Low / Continuous 3 ~$32,600

M005 ~8,170 Sq. Ft. – Concrete and/or Wood X Low / Rarely 2 ~$36,765

M005 ~20 Sq. Ft. – Concrete 5 High / Continuous 1 ~$200

M009 ~4 Lin. Ft. – Metal 5 Moderate / Periodic 1 ~$100

M012 2 Units - Metal X Low / Rarely 2 ~$50

M015 ~6 Lin. Ft. – Roofing X Low / Rarely 2 ~$50

M016 4 Units - Metal X Low / Rarely 2 ~$100

T001 ~51 Units – Metal 5 Low / Rarely 2 ~$1,020

T002 ~8 Units – Metal 5 Low / Rarely 2 ~$160

Damage Assessment Categories 1-Damaged or significantly damaged thermal system insulation ACM 2-Damaged friable surfacing ACM 3-Significantly damaged friable surfacing ACM 4-Damaged or significantly damaged friable miscellaneous ACM 5-ACM with potential for damage 6-ACM with potential for significant damage 7-Any remaining friable ACM or friable suspect ACM X-Not applicable (non-friable surfacing or miscellaneous material)

Recommended Response Actions 1-Regulated ACM (EPA, Wyoming Department of Environmental Quality, and OSHA) – Repair or remove immediately 2-Regulated ACM (EPA, Wyoming Department of Environmental Quality, and OSHA) – Remove prior to disturbance 3-Regulated asbestos material (OSHA only) – Remove prior to disturbance

Appendix A

Laboratory Analytical Reports

Approved by:

Approved Signatory Renee Luna

Report for:

Mr. John Larson IHI Environmental, Salt Lake City 640 E. Wilmington Avenue Salt Lake City, UT 84106

Regarding: Project: AL147459; Supervisor's Office

EML ID: 1246150

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos-EPA Method 600/R-93/116: 08-15-2014

Service SOPs: Asbestos-EPA Method 600/R-93/116 (EPA-600/M4-82-020 (SOP 01267))

EMLab ID: 1246150, Page 1 of 11Aerotech Laboratories, Inc

EMLab P&K 1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-15-2014

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Total Samples Submitted: 32 Total Samples Analysed: 32

Total Samples with Layer Asbestos Content > 1%: 14

Location: 1, 47459E-1 Wall System Lab ID-Version‡: 5670863-1

Sample Layers Asbestos Content White Drywall with Brown Paper ND

White Joint Compound 2% Chrysotile Cream Tape ND

White Texture with Purple Paint 2% Chrysotile Composite Asbestos Fibrous Content: < 1% Asbestos

Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Comments: Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.

Location: 2, 47459E-2 Wall System Lab ID-Version‡: 5670864-1

Sample Layers Asbestos Content White Drywall with Brown Paper ND

White Joint Compound 2% Chrysotile Cream Tape ND

White Texture with Multilayered Paint 2% Chrysotile Composite Asbestos Fibrous Content: < 1% Asbestos

Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Comments: Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.

Location: 3, 47459E-3 Wall System Lab ID-Version‡: 5670865-1

Sample Layers Asbestos Content White Drywall with Brown Paper ND

White Joint Compound 2% Chrysotile Cream Tape ND

White Texture with Multilayered Paint < 1% Chrysotile Composite Asbestos Fibrous Content: < 1% Asbestos

Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Comments: Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.

EMLab ID: 1246150, Page 2 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-15-2014

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: 4, 47459E-4 Wall System Lab ID-Version‡: 5670866-1

Sample Layers Asbestos Content White Drywall with Brown Paper ND

White Joint Compound 2% Chrysotile Cream Tape ND

White Texture with Multilayered Paint 2% Chrysotile Composite Asbestos Fibrous Content: < 1% Asbestos

Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor

Comments: Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.

EMLab ID: 1246150, Page 3 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-15-2014

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: 5, 47459E-5 Ceiling Tile Lab ID-Version‡: 5670867-1

Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 45% Glass Fibers 40% Cellulose

Sample Composite Homogeneity: Good

Location: 6, 47459E-6 Ceiling Tile Lab ID-Version‡: 5670868-1

Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 45% Glass Fibers 40% Cellulose

Sample Composite Homogeneity: Good

Location: 7, 47459E-7 Ceiling Tile Lab ID-Version‡: 5670869-1

Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 45% Glass Fibers 40% Cellulose

Sample Composite Homogeneity: Good

Location: 8, 47459E-8 Ceiling Tile Lab ID-Version‡: 5670870-1

Sample Layers Asbestos Content Gray Ceiling Tile with White Surface ND

Composite Non-Asbestos Content: 45% Glass Fibers 40% Cellulose

Sample Composite Homogeneity: Good

EMLab ID: 1246150, Page 4 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-15-2014

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: 9, 47459E-9 Carpet Adhesive Lab ID-Version‡: 5670871-1

Sample Layers Asbestos Content Yellow Adhesive ND

Composite Non-Asbestos Content: < 1% Synthetic Fibers Sample Composite Homogeneity: Good

Location: 10, 47459E-10 Carpet Adhesive Lab ID-Version‡: 5670872-1

Sample Layers Asbestos Content Yellow Adhesive ND

Composite Non-Asbestos Content: < 1% Synthetic Fibers Sample Composite Homogeneity: Good

Location: 11, 47459E-11 Sheet Vinyl Lab ID-Version‡: 5670873-1

Sample Layers Asbestos Content Beige Sheet Flooring ND

Yellow Mastic ND Sample Composite Homogeneity: Moderate

Location: 12, 47459E-12 Floor Tile And Mastic Lab ID-Version‡: 5670874-1

Sample Layers Asbestos Content Yellow Mastic ND Tan Floor Tile < 1% Chrysotile Black Mastic 5% Chrysotile

Sample Composite Homogeneity: Poor

EMLab ID: 1246150, Page 5 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-15-2014

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: 13, 47459E-13 Roof Core Lab ID-Version‡: 5670875-1

Sample Layers Asbestos Content Black Roofing Material with Brown Pebbles ND

Black Roofing Tar and Felt ND Brown Roofing Material ND

Composite Non-Asbestos Content: 40% Cellulose 10% Glass Fibers 5% Synthetic Fibers

Sample Composite Homogeneity: Poor

Location: 14, 47459E-14 Roof Core Lab ID-Version‡: 5670876-1

Sample Layers Asbestos Content Black Roofing Material with Brown Pebbles ND

Black Roofing Tar and Felt ND Brown Roofing Material with Tan Wood ND

Composite Non-Asbestos Content: 40% Cellulose 10% Glass Fibers 5% Synthetic Fibers

Sample Composite Homogeneity: Poor

Location: 15, 47459E-15 Roof Core Lab ID-Version‡: 5670877-1

Sample Layers Asbestos Content Black Roofing Material with Brown Pebbles ND

Black Roofing Tar and Felt ND Black Roofing Tar and Felt ND

Brown Roofing Material with Tan Wood ND Composite Non-Asbestos Content: 40% Cellulose

10% Glass Fibers 5% Synthetic Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1246150, Page 6 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-15-2014

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: 16, 47459E-16 Roof Core Lab ID-Version‡: 5670878-1

Sample Layers Asbestos Content Black Roofing Material with Brown Pebbles ND

Black Roofing Tar and Felt ND Brown Roofing Material with Tan Wood ND

Composite Non-Asbestos Content: 40% Cellulose 10% Glass Fibers 5% Synthetic Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1246150, Page 7 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-15-2014

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: 17, 47459E-17 Roof Felt Lab ID-Version‡: 5670879-1

Sample Layers Asbestos Content Brown/Black Roofing Felt ND

Composite Non-Asbestos Content: 70% Cellulose Sample Composite Homogeneity: Good

Location: 18, 47459E-18 Pipe Insulation Lab ID-Version‡: 5670880-1

Sample Layers Asbestos Content Off-White Insulation 2% Chrysotile

< 1% Amosite Cream Wrap with Purple Paint ND

Composite Non-Asbestos Content: 25% Glass Fibers 10% Cotton

Sample Composite Homogeneity: Moderate

Location: 19, 47459E-19 Gasket Lab ID-Version‡: 5670881-1

Sample Layers Asbestos Content Off-White Gasket ND

Composite Non-Asbestos Content: 99% Glass Fibers Sample Composite Homogeneity: Good

Location: 20, 47459E-20 Duct Tape Lab ID-Version‡: 5670882-1

Sample Layers Asbestos Content Brown/Black Tape 60% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1246150, Page 8 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-15-2014

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: 21, 47459E-21 Thin Set Lab ID-Version‡: 5670883-1

Sample Layers Asbestos Content Gray Thinset ND

Composite Non-Asbestos Content: < 1% Cellulose Sample Composite Homogeneity: Good

Location: 22, 47459E-22 Adhesive Lab ID-Version‡: 5670884-1

Sample Layers Asbestos Content Tan Adhesive ND

Sample Composite Homogeneity: Good

Location: 23, 47459E-23 Floor Tile And Mastic Lab ID-Version‡: 5670885-1

Sample Layers Asbestos Content Tan Floor Tile < 1% Chrysotile Black Mastic 5% Chrysotile

Composite Non-Asbestos Content: < 1% Cellulose Sample Composite Homogeneity: Moderate

Location: 24, 47459E-24 Mastic Lab ID-Version‡: 5670886-1

Sample Layers Asbestos Content Black Mastic 7% Chrysotile

Composite Non-Asbestos Content: < 1% Cellulose < 1% Hair/Wool < 1% Synthetic Fibers

Sample Composite Homogeneity: Good

EMLab ID: 1246150, Page 9 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-15-2014

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: 25, 47459E-25 Lab ID-Version‡: 5670887-1

Sample Layers Asbestos Content Yellow Mastic ND Tan Floor Tile < 1% Chrysotile

Black Mastic with Fibrous Material 5% Chrysotile Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Poor

Location: 26, 47459E-26 Lab ID-Version‡: 5670888-1

Sample Layers Asbestos Content Off-White Insulation 2% Chrysotile

< 1% Amosite Cream Wrap ND

Composite Non-Asbestos Content: 25% Glass Fibers 10% Cotton

Sample Composite Homogeneity: Moderate

Location: 27, 47459E-27 Lab ID-Version‡: 5670889-1

Sample Layers Asbestos Content Off-White Insulation 2% Chrysotile

< 1% Amosite Cream Wrap with Yellow Surface ND

Composite Non-Asbestos Content: 25% Glass Fibers 10% Cotton

Sample Composite Homogeneity: Moderate

Location: 28, 47459E-28 Lab ID-Version‡: 5670890-1

Sample Layers Asbestos Content Semi-Transparent Mastic with Multilayered Paint ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 1246150, Page 10 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-15-2014

ASBESTOS PLM REPORT: EPA-600/M4-82-020 & EPA METHOD 600/R-93-116

Location: 29, 47459E-29 Lab ID-Version‡: 5670891-1

Sample Layers Asbestos Content Semi-Transparent Mastic with Multilayered Paint ND

Composite Non-Asbestos Content: 5% Cellulose Sample Composite Homogeneity: Moderate

Location: 30, 47459E-30 Lab ID-Version‡: 5670892-1

Sample Layers Asbestos Content Semi-Transparent Mastic with Multilayered Paint ND

Tan Wood ND Composite Non-Asbestos Content: 35% Cellulose Sample Composite Homogeneity: Moderate

Location: 31, 47459E-31 Lab ID-Version‡: 5670893-1

Sample Layers Asbestos Content Black Roofing Mastic 10% Chrysotile

Dark Brown Roofing Felt ND Black Roofing Tar ND

Brown Roofing Material ND Composite Non-Asbestos Content: 40% Cellulose Sample Composite Homogeneity: Poor

Location: 32, 47459E-32 Lab ID-Version‡: 5670894-1

Sample Layers Asbestos Content Black Roofing Mastic with Gray Surface 10% Chrysotile

Gray Cementitious Material ND Composite Non-Asbestos Content: 40% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 1246150, Page 11 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

Approved by:

Approved Signatory Renee Luna

Report for:

Mr. John Larson IHI Environmental, Salt Lake City 640 E. Wilmington Avenue Salt Lake City, UT 84106

Regarding: Project: AL147459; Supervisor's Office

EML ID: 1246150

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. Due to the nature of the analyses performed, field blank correction of results is not applied. The results relate only to the items tested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos-EPA 400 point count: 08-25-2014

Service SOPs: Asbestos-EPA 400 point count (EPA Method 600/R-93/116 (EPA-600/M4-82-020 (SOP 01262))

EMLab ID: 1246150, Page 1 of 2Aerotech Laboratories, Inc

(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: IHI Environmental, Salt Lake City C/O: Mr. John Larson Re: AL147459; Supervisor's Office

Date of Receipt: 08-12-2014 Date of Report: 08-25-2014

ASBESTOS POINT COUNT REPORT: EPA METHOD 600/R-93-116

Location: 4 47459E-4 Wall System

Total Points Counted: 400

Lab ID-Version‡: 5685532-1

Sample Layers Asbestos Type Asbestos Points Counted

Asbestos Concentration (%)

White Drywall /Joint Compound Chrysotile 0 < 0.25 Layer Totals: 0 NA

Comments:Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines.

EMLab ID: 1246150, Page 2 of 2Aerotech Laboratories, Inc

The results relate only to the items tested. Interpretation is left to the company and/or persons who conducted the field work. The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

All samples were received in acceptable condition unless otherwise noted. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

Appendix B

Photographic Log of Materials Sampled

Photograph 1 OSHA-regulated wall system, homogeneous area M001.

Photograph 2 Non-ACM suspended ceiling panels, homogeneous area M002.

Photograph 3 Non-ACM carpet adhesive, homogeneous area M003.

Photograph 4 Non-ACM vinyl floor sheeting, homogeneous area M004.

Photograph 5 ACM floor tile and mastic, homogeneous area M005.

Photograph 6 Non-ACM roof sheeting, homogeneous area M006.

Photograph 7 Non-ACM roofing felt under wood shingles, homogeneous area M007.

Photograph 8 ACM pipe-fitting insulation on heating system, homogeneous area T001.

Photograph 9 Non-ACM boiler gasket, homogeneous area M008.

Photograph 10 ACM duct tape, homogeneous area M009.

Photograph 11 Non-ACM ceramic tile thin-set and adhesive, homogeneous area M010 and M011.

Photograph 12 ACM pipe-fitting insulation on the roof drain system, homogeneous area T002.

Photograph 13 Assumed ACM light fixture wire insulation, homogeneous area M012.

Photograph 14 Non-ACM exterior caulking, homogeneous area M013.

Photograph 15 Non-ACM roofing tar and felt, with ACM tar sealant, homogeneous areas M014 and M015.

Appendix C

Asbestos Sampling Locations (Drawing)

B o i l e r

18 19

3 2

Asbestos Sample Number & Location

Explanation

Drawn By:

Checked By:

Approved By:

Project Mngr:

File No.

Date:

Scale:

Project No. FIG. No.

640 East Wilmington Avenue Salt Lake City, Utah

FAX. (801) 466-9616PH. (801) 466-2223

A

COMPANY

Supervisor's Office - First Floor - Building # TN80101JHS

Keith

JCL

JRB

AL147459

1" = 20' - 0"

AL147459.dwg

August 2014

United States Forest Service Pre-Demolition Inspection Case Lowe & Hart, Inc.

340 North Cache Street Jackson, Wyoming

N

SCALE IN FEET

1050 20

N P r o j e c t s A

L W o r k i n g

F i l e s D i a g r a m s D r a w i n g s F i g u r e s A

L d w g f i g b l d g e s u p e r o f f f l r

A

M k f a r r e l l

A

N S

I f u l l b l e e d

A x

I n c h e s

Roof

Roof

14Roof

15Roof

13 Roof

Roof

Asbestos Sample Number & Location

Explanation

Note:

Sample Numbers 13, 14, 15, 16, 17, 31, & 32 are Roof Samples

Drawn By:

Checked By:

Approved By:

Project Mngr:

File No.

Date:

Scale:

Project No. FIG. No.

640 East Wilmington Avenue Salt Lake City, Utah

FAX. (801) 466-9616PH. (801) 466-2223

A

COMPANY

Supervisor's Office - Second Floor - Building # TN80101JHS

Keith

JCL

JRB

AL147459

1" = 20' - 0"

AL147459.dwg

August 2014

United States Forest Service Pre-Demolition Inspection Case Lowe & Hart, Inc.

340 North Cache Street Jackson, Wyoming

N

SCALE IN FEET

1050 20

N P r o j e c t s A

L W o r k i n g

F i l e s D i a g r a m s D r a w i n g s F i g u r e s A

L d w g f i g b l d g e s u p e r o f f f l r

A

M k f a r r e l l

A

N S

I f u l l b l e e x

I n c h e i l e r

3 1 2 4

Explanation

Asbestos-Containing Duct Tape

Note:

OSHA regulated wall system throughout on walls and walls and ceilings in restrooms

Asbestos-Containing Pipe Fittings Insulation

Asbestos-Containing Wire Insulation

Asbestos-Containing Floor Tile & Adhesive

Drawn By:

Checked By:

Approved By:

Project Mngr:

File No.

Date:

Scale:

Project No. FIG. No.

640 East Wilmington Avenue Salt Lake City, Utah

FAX. (801) 466-9616PH. (801) 466-2223

A

COMPANY

Supervisor's Office - First Floor - Building # TN80101JHS

Keith

JCL

JRB

AL147459

1" = 20' - 0"

AL147459.dwg

August 2014

United States Forest Service Pre-Demolition Inspection Case Lowe & Hart, Inc.

340 North Cache Street Jackson, Wyoming

N

SCALE IN FEET

1050 20

N P r o j e c t s A

L W o r k i n g

F i l e s D i a g r a m s D r a w i n g s F i g u r e s A

L d w g f i g b l d g e s u p e r o f f f l r

A

M k f a r r e l l

A

N S

I f u l l b l e e x

I n c h e

2 2

Explanation

Note:

OSHA regulated wall system throughout on walls and walls and ceilings in restrooms

Asbestos-Containing Pipe Fittings Insulation

Asbestos-Containing Wire Insulation

Asbestos-Containing Floor Tile & Adhesive

Asbestos-Containing Tar Sealant

Drawn By:

Checked By:

Approved By:

Project Mngr:

File No.

Date:

Scale:

Project No. FIG. No.

640 East Wilmington Avenue Salt Lake City, Utah

FAX. (801) 466-9616PH. (801) 466-2223

A

COMPANY

Supervisor's Office - Second Floor - Building # TN80101JHS

Keith

JCL

JRB

AL147459

1" = 20' - 0"

AL147459.dwg

August 2014

United States Forest Service Pre-Demolition Inspection Case Lowe & Hart, Inc.

340 North Cache Street Jackson, Wyoming

N

SCALE IN FEET

1050 20

N P r o j e c t s A

L W o r k i n g

F i l e s D i a g r a…