Addendum 1 22029.pdf
PDF 4 MB Posted
- Solicitation number
- RFQ 171 220000000521 4
- Issued by
- Wexford County, Burt CDP, Michigan
About this file
This Addendum #1, issued September 2, 2022, by the Michigan Department of Technology, Management & Budget (DTMB) in coordination with the Department of Natural Resources, pertains to the Mitchell State Park South Toilet Shower Building Replacement project in Cadillac, Michigan (Project No. 22.102, DTMB File No. 751/22029.JAN). The project involves demolition of the existing toilet and shower facility and construction of a replacement building featuring masonry cavity exterior wall construction with split face veneer, interior masonry walls to 8 feet with epoxy paint, exposed timber columns and trusses, standing seam metal roof with asphalt shingle alternate, aluminum frame windows and doors, and wood tongue-and-groove finishes. A mandatory pre-bid conference was held on August 31, 2022, with a bid submission deadline of September 14, 2022 at 2:00 PM through the SIGMA website. Post-bid interviews were scheduled for September 16, 2022. The contract term is 206 calendar days from the Notice-to-Proceed or by May 12, 2023, with liquidated damages of $2,000 per day. The addendum addresses three substitution requests: rejection of Navien Tankless Hot Water heaters in favor of tank-type units, approval of DMI Inter-Lock Standing Seam Metal Roofing as an equal substitute, and approval of an alternative lighting package with noted conditions.
The project includes a $50,000 Owner's Provisional Allowance in the base bid, two alternates (delete labor and materials for sealed polished concrete floors and delete labor and materials for asphalt shingle roofing), and prevailing wage rate requirements. Bidders must provide a 5% bid security, signed Bid Summary Form, Bid Schedule, Qualified Disabled Veteran (QDV) Business Representation if applicable, and Michigan-based business certification for projects over $100,000. Payment and Performance Bonds are required upon Notice of Award. Best value evaluation will compare the three lowest responsive and responsible bidders based on price and qualitative components. The project is subject to hazardous materials reports for PCB, asbestos, and paint; materials testing by owner; geotechnical requirements including peat removal and dewatering provisions; and permitting reviews by LARA, EGLE, District Health Department 10, and DTMB SESC. Winter access conditions apply, with the contractor responsible for site plowing and restoration, and the campground scheduled to close for construction with potential north loop reopening at end of April 2023.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
440 Bridge Street 122 S. Union Street, Suite 200 Grand Rapids, MI 49504 Traverse City, MI 49684 P 616 774 0100 P 231 947 2177 www.cornerstone‐arch.com
Mitchell State Park‐ South Toilet Shower Building Replacement Cadillac, MI
Project No.: 22.102 DTMB File No. 751/22029.JAN
Addendum #1 Issued Date: September 2, 2022
To: Potential Bidders
Cc: Jan Miller, DTMB Project Director
The following changes are made a part of the Drawings and Specifications for the subject project dated August 18, 2022.
All contractors, subcontractors, material suppliers and other involved parties shall be responsible for reading the entire Addendum. Failure to list an item(s) in all affected sections of this Addendum does not relieve any party affected from performing per instructions, provided the information is set forth one time anywhere in the Addendum.
This document shall become attached to and part of the Bidding Documents for the aforementioned project. All requirements contained in the Bidding Documents shall apply to this Request. All incidental work necessary to complete the Work shall be included in the Contractor’s quotation even though not particularly mentioned.
Description:
See attached ADD #1 write‐up and the documents associated.
Sent by:
Anna Kindt
122 S Union Street, Suite 200 Traverse City, MI 49684 440 Bridge Street NW Grand Rapids, MI 49504 P 231 947 2177 F 231 933 4310 P 616 774 0100 F 616 774 2956
Mitchell State Park‐ South Toilet Shower Building Replacement Cadillac, MI
Project No.: 22.102 DTMB File No. 751/22029.JAN
ADDENDUM #0001
9/2/22 Cadillac, Michigan 22.102
This addendum is notification to all bidders on the above-mentioned project that the following revisions to the Construction Documents are to be incorporated into any bid proposals submitted.
Drawings issued with this Addendum:
SK Detail Sheets issued with this Addendum:
1) none.
Clarification and Additional Information from Pre-bid Walk Thru:
1) See attached DTMB agenda.
2) See attached Cornerstone Architects project scope summary.
3) See attached Cornerstone Architects meeting notes.
4) Pre-bid sign in sheet posted as separate addenda.
Specification Revisions:
1) None.
Specifications issued with this Addendum:
1) None
Revisions to Bid Specifications issued with this Addendum:
Substitution Request:
1) Proposed Substitution Mitchell SP 001: Request to substitute Navien Tankless Hot
Water instead of tank-type specified.
Rejected. See attached request.
2) Proposed Substitution Mitchell SP 002: Request to substitute DMI Inter-Lock Standing
Seam Metal Roofing as equal to that specified.
Approved. See attached request.
3) Proposed Substitution Mitchell SP 003: Request to substitute lighting package fixtures.
Approved as Noted. See attached request.
Bid Requests for Information:
Drawing Revisions:
Site: none Architectural: none Structural: none
122 S Union Street, Suite 200 Traverse City, MI 49684 440 Bridge Street NW Grand Rapids, MI 49504 P 231 947 2177 F 231 933 4310 P 616 774 0100 F 616 774 2956
Mechanical: none Electrical: none Plumbing: none
End of ADDENDUM #Mitchell SP 0001
GRETCHEN WHITMER
GOVERNOR
STATE OF MICHIGAN
DEPARTMENT OF TECHNOLOGY, MANAGEMENT & BUDGET
LANSING
BROM STIBITZ
ACTING DIRECTOR
DESIGN & CONSTRUCTION DIVISION
3111 W. ST. JOSEPH STREET ● LANSING, MICHIGAN 48917
www.michigan.gov/dtmb ● 517-284-7910
State Facilities Administration - Design & Construction Division Mandatory Pre-Bid Conference Agenda
Date: Wednesday, August 31, 2022 @ 11:00 AM
Department of Natural Resources, Parks & Recreation Division Mitchell State Park Campground – South Toilet Shower Building Replacement
File No. 751/22029.JAN – Index No. 5126
1. Introductions / Sign-in Sheet
2. Bid Submission - bids must be submitted electronically through the SIGMA website at https://sigma.michigan.gov/webapp/PRDVSS2X1/AltSelfService no later than Wednesday, Sept. 14, 2022 @ 2:00 pm local time. Hard copy bids will not be accepted.
3. Bid to include, refer to Section 00100 – Instructions to Bidders Signed and completed Bid Summary Form Bid Schedule Qualified Disabled Veteran (QDV) Business Representation, if applicable Signed Certification of a Michigan Based Business (projects over $100,000.00) Bid Security in the amount of 5% of Base Bid Price Signature Authorization or copy of the partnership agreement if signed by all partners Post-Bid Submittals will be requested by the professional (projects over
$250,000.00) from the apparent low bidder, within one business day after receipt of the request. Interview(s) will be scheduled for September 16, 2022.
4. Modification of bid – the entire bid must be resubmitted on the SIGMA website.
5. Payment and Performance Bonds will be required upon issuing Notice of Award.
6. Qualified Disabled Veteran Preference is in effect, make sure to check the box on the
Bid Summary Form.
7. Best Value Bidder – bids will be evaluated for best value based on price and qualitative components by comparing the three lowest responsive and responsible bidders.
8. Prevailing Wage Rates
9. Contract Time – 206 calendar days from the Notice-to-Proceed or by May 12, 2023.
10. Liquidated Damages - $2,000.00 per day
11. Alternate 1 – Delete labor & materials to change polished concrete floors to sealed.
Alternate 2 – Delete labor & materials to change sheet metal roofing to asphalt shingle.
12. Allowances - $50,000 Owner’s Provisional Allowance, to be included in base bid
13. Hazardous Materials Report – PCB, asbestos, and paint
14. Materials Testing – By owner
15. Schedule
Questions to akindt@cornerstone-arch.com no later than 5:00 pm, Sept. 7, 2022.
Addenda issued no later than 5:00 pm, Sept. 9, 2022 Bids due Sept. 14, 2022 @ 2:00 pm local time
16. Project Description – Cornerstone Architects
17. Site Tour
P 616 774 0100 P 231 947 2177 www.cornerstone‐arch.com
Mitchell State Park‐ South Toilet Shower Building Replacement Cadillac, MI
Project No.: 22.102 DTMB File No. 751/22029.JAN
Date: August 31, 2022 @ 11am
Meeting Info: Meet at Park Headquarters.
Project Scope:
1. General:
a. Job trailer allowed on site. Contractor to provide their own toilet facilities.
Locations to be worked out with DNR.
b. For winter access, the Park will plow the main road coming into the park. The contractor will be responsible for plowing the loops up to the building and any areas surrounding that are needed for a job trailer, equipment, staging and etc… The contractor will be responsible for restoration of any areas damages by plowing.
c. Campground will be completely closed starting this fall for construction. They are tentatively planning to open the north loops only at the end of April 2023 depending on construction progress (north loops would use the other north TS building).
d. Permitting:
i. Submitted to LARA for construction codes review.
ii. Submitted to EGLE for campground review.
iii. Submitted to District Health Department 10 for review.
iv. DTMB doing SESC review and permitting in‐house (application provided in specs).
e. Please use Substitution Request Form included in specs if you want to request a substitution.
2. Demolition:
a. Hazardous material remediation to be completed By Contractor prior to start of demo. Work to be included in your bid. Reports are in the specifications.
b. The building is on municipal electric, gas and water/sewer. Existing connections will be reworked or replaced per plans. Protect anything to remain during demo.
Coordinate any shutoffs and connections with the utility companies.
c. Salvage and provide to Owner: Birding signage, ’10‐Minute’ parking signs and posts.
Pre‐Bid Meeting:
3. Site Work:
a. Geotech report included in specs. Layer of peat about 5.5‐7’ down that needs to be removed below the building footprint per the report‐ will lead to over‐excavation.
The report has recommendations for a suitable fill to provide bearing.
b. Dewatering will be needed as water level is 3.5’ down. See Geotech report and civil spec for dewatering method options. Peat material may need to drain prior to hauling. The contractor will be able to work with the Park to find a location on site for draining prior to hauling. The contractor would then be responsible for restoration of the preapproved location along with any other areas damaged by dewatering activities.
c. New concrete sidewalks, parking, grading, and utility connections per plans.
d. Building footing drain to be connected to existing site storm water system.
e. Bike racks themselves are By Owner, though contractor to provide concrete pad as shown on plans.
f. New parking paving can be either concrete or asphalt, at the contractors option
(whatever provides the best pricing).
4. Proposed:
a. Based on prototype but with park specific modifications to the floor plan.
i. Masonry cavity exterior wall construction, split face veneer with two bands of smooth face accent and columns.
ii. Interior walls masonry (to 8’ ht) with epoxy paint and wood frame with wood siding above.
iii. Exposed timber columns and trusses at gable porches.
iv. Rafter and truss framed wood roof structure.
v. Standing seam metal roof with alternate for asphalt shingle. See drawing description for what materials to change for alternate, and see specs for materials for each system.
vi. Aluminum frame windows, project‐in vents where shown.
vii. Aluminum doors and frames.
viii. Wood tongue‐and‐groove used on exterior and interior at soffits, ceilings, siding, wall paneling.
ix. Foundations can be either block as shown or poured concrete, at the contractors option (whatever provides the best pricing).
1. Footings to bear on new fill, per Geotech, with footing drain system to deal with high water table.
b. Structural
i. All floor slabs to slope to floor drains.
ii. Note overframing at eastern half of building to achieve gables.
iii. Exposed timber trusses at gables has high and low beams that bear back to masonry and wood framing at building.
c. Plumbing
i. Using rear‐access shower controls so can be maintained from mechanical room.
ii. Note shut off valves at each fixture.
iii. Tank type hot water heaters.
iv. Water runs, furnace ducting and electrical panel locations get tight for overhead clearance. We’ve worked to provide proper locations, but will need to be kept track of and coordinated by the contractor.
d. Mechanical
i. Ducted gas furnace with energy recovery ventilator.
ii. Ducting in mechanical area to be run along sloped ceiling to maintain head height.
iii. Outdoor air and exhaust air louver in architectural spec and detail provided for how to install custom shape louver in gable ends.
e. Electrical
i. Building has generator receptacle and transfer switch, but generator not included in project.
ii. Existing Loon Cabin feeder run through panel at this building. Feeder to be replaced as part of this project.
f. Substitution Requests:
i. A substitution request for tankless has been rejected (info to be included in addenda).
ii. Standing seam metal roofing approved substitution info will be in addenda.
Project Schedule:
5. Bid questions due to Anna by Wednesday, September 7 by 5pm.
6. Jan reviewed bid dates (Wednesday, September 14 at 2pm due on SIGMA).
7. Once bids are received, post‐bid submittals will be requested by Anna, to be received within one day (would like to receive Thursday).
8. Post‐bid interviews will be scheduled the morning of Friday, September 16.
REVIEW ON SITE:
1. Site walk.
P 616 774 0100 P 231 947 2177 www.cornerstone‐arch.com
Mitchell State Park‐ South Toilet Shower Building Replacement Cadillac, MI
Project No.: 22.102 DTMB File No. 751/22029.JAN
Pre‐Bid Meeting Notes Date: Wednesday, August 31, 2022, 1pm Location: Park HQ and existing T/S site In Attendance: Jan Miller, DTMB Project Director Annamarie Bauer, DNR PDR Regional Planner Ben Dietrich, DNR Park Supervisor Kasey Mahoney, DNR Cadillac District Supervisor Anna Kindt, Cornerstone Potential Bidders (see sign in sheet)
Meeting Notes:
1. Jan Miller reviews DTMB agenda (see attached).
2. Anna Kindt reviews project scope summary (see attached).
3. Contractor Q&A:
a. Winter conditions are required.
b. A full time site supervisor is required.
c. Question regarding applicability of ADA laws to project and what review standards the project is required to meet.
i. The project is required to meet ADA and was designed to State applicable standards.
ii. LARA will be reviewing ADA standards under their jurisdiction.
iii. The DTMB does not override applicable ADA guidelines.
a. Plumbing review is at the State level. If there is turnover in that position, we will still need to work with the State as they are the authority having jurisdiction over the project.
b. Question if dewatering can be discharged into the stormwater system.
i. Architect working with Civil engineer to determine requirements. Further information will be issued in a future addenda.
c. Question regarding how frost laws, hauling requirements and existing road condition will impact project and any responsibility the contractor has for the road condition after the project.
i. DNR and DTMB currently reviewing expectations. Further information will be issued in a future addenda. Existing asphalt on road surface believed to be approximately 1” thick.
End of Notes.
Dick Vredevoogd, Specification and Project Manager 8/23/22 Balfrey-Johnston Inc
13050 Northend Ave Oak Park MI 48237 248-384-8781 313864-7219
Plumbing Equipment and Materials Product Equipment
22 00 10 2 I. Plumbing Equipment
Navien NPE-240S2 Condensing Tankless Water Heaters Navien
Navien NPE-240S2 www.navieninc.com
Dick Vredevoogd, Specification and Project Manager
A. Kindt 8/30/22 x x x
T H E L E A D E R I N C O N D E N S I N G T E C H N O L O G Y
QuickFacts eriesNPE-2 Se ater HeatersTankless Wa
Navien Certification Summary Note: all NPE-2 models are field convertible from NG to LP gas
Model
Product Approvals Efficiency Ratings* Annual Energy Consumption*
(Residential)
CSA
NSF
(Standard 5) Low Lead (<0.25%)
SCAQMD 1146.2
(NOx, <20ppm)
AHRI
Number
Energy Star
Uniform Energy Factor
(UEF)
Max GPM (L/m) (67°F Rise)
Natural Gas (Therms/Year)
Propane (Gallons/
Year)
Estimated Operating
Cost**
NPE-180A2-NG Yes Yes Yes Yes 206368357 Yes 0.95 4.3 (16) 179 $195
NPE-180A2-LP Yes Yes Yes Yes 206368357 Yes 0.95 4.3 (16) 196 $472
NPE-210A2-NG Yes Yes Yes Yes 206368358 Yes 0.95 5.1 (19) 179 $195
NPE-210A2-LP Yes Yes Yes Yes 206368358 Yes 0.95 5.1 (19) 196 $472
NPE-240A2-NG Yes Yes Yes Yes 206368359 Yes 0.95 5.6 (21) 179 $195
NPE-240A2-LP Yes Yes Yes Yes 206368359 Yes 0.95 5.6 (21) 196 $472
NPE-150S2-NG Yes Yes Yes Yes 206423843 Yes 0.93 3.4 (13) 120 $131
NPE-150S2-LP Yes Yes Yes Yes 206423843 Yes 0.93 3.4 (13) 131 $316
NPE-180S2-NG Yes Yes Yes Yes 206368360 Yes 0.96 4.4 (17) 177 $193
NPE-180S2-LP Yes Yes Yes Yes 206368360 Yes 0.96 4.4 (17) 194 $468
NPE-210S2-NG Yes Yes Yes Yes 206368361 Yes 0.96 5.3 (20) 177 $193
NPE-210S2-LP Yes Yes Yes Yes 206368361 Yes 0.96 5.3 (20) 194 $468
NPE-240S2-NG Yes Yes Yes Yes 206368362 Yes 0.96 5.8 (22) 177 $193
NPE-240S2-LP Yes Yes Yes Yes 206368362 Yes 0.96 5.8 (22) 194 $468
*Based on U.S. Department of Energy (DOE) test procedures.
**Based on a national average natural gas cost of $1.09/therm, propane cost of $2.41/gallon.
Temperature Rise (maximum output)
Temp Rise (°F)
150S2 GPM (L/m)
180A2/S2 GPM (L/m)
210A2/S2 GPM (L/m)
240A2/S2 GPM (L/m)
35 6.8 (26) 8.4 (32) 10.1 (38) 11.2 (42)
40 5.9 (22) 7.4 (28) 8.8 (33) 9.8 (37)
45 5.3 (20) 6.5 (25) 7.8 (30) 8.7 (33)
50 4.8 (18) 5.9 (22) 7.1 (27) 7.8 (30)
55 4.3 (16) 5.3 (20) 6.4 (24) 7.1 (27)
60 4.0 (15) 4.9 (19) 5.9 (22) 6.5 (25)
65 3.7 (14) 4.5 (17) 5.4 (20) 6.0 (23)
70 3.4 (13) 4.2 (16) 5.0 (19) 5.6 (21)
75 3.2 (12) 3.9 (15) 4.7 (18) 5.2 (20)
80 3.0 (11) 3.7 (14) 4.4 (17) 4.9 (19)
85 2.8 (11) 3.5 (13) 4.2 (16) 4.6 (17)
90 2.6 (10) 3.3 (12) 3.9 (15) 4.4 (17)
100 2.4 (9) 2.9 (11) 3.5 (13) 3.9 (15)
110 2.2 (8) 2.7 (10) 3.2 (12) 3.6 (14)
120 2.0 (8) 2.5 (9) 2.9 (11) 3.3 (12)
130 1.8 (7) 2.3 (9) 2.7 (10) 3.0 (11)
140 1.7 (6) 2.1 (8) 2.5 (9) 2.8 (11)
DHW Capacity
Models Natural Gas (BTU/H) Propane Gas (BTU/H)
NPE-150S2 18,000–120,000 18,000–120,000
NPE-180A2/S2 10,000–150,000 10,000–150,000
NPE-210A2/S2 12,000–180,000 12,000–180,000
NPE-240A2/S2 13,300–199,900 13,300–199,900
Operating Cost
Navien tankless 179 therms $195*
Other tankless 209 therms $228*
Standard tank 269 therms $293*
* Based on Energy Guide cost estimates using $1.09 per therm of natural gas. Cost is in US dollars.
Warranty
Application Labor Parts Heat
Exchanger
Residential
Standard or controlled recirculation2 1 year 5 years 15 years
Uncontrolled recirculation3 1 year 3 years 5 years
Commercial or Combi1
Standard or controlled recirculation2 1 year 5 years 8 years
Uncontrolled recirculation3 1 year 3 years 3 years
1 Combi refers to a combination potable water and space heating application. Water heaters cannot be used in space heating only applications.
2 Controlled-Recirculation: Recirculation through the water heater is controlled by either the water heater or an external aquastat.
3 Uncontrolled-Recirculation: External pumps configured to circulate continuously through the water heater are subject to the uncontrolled recirculation warranty terms. An aquastat is the minimum pump control requirement for DHW or storage tank recirculation in order to maintain the full controlled recirculation warranty.
For complete details please refer to the full warranty at Navieninc.com.
U.S. Green Building Council LEED Points*
Water Heater Location Recirculation
1.5 Points 2 Points 3 Points
Lower HERS Home Index Score*
* Please consult your Energy/LEED consultant.
Product Features
0.9
UP TO
U E F6
NPE-A2 COMFORT FLOW
BUILT-IN BUFFER TANK
& RECIRCULATION PUMP
TDR
GAS
UP TO
24 FEET
VENT
UP TO
75 FEET
22 &
DUAL
HEAT EXCHANGERS
STAINLESS
STEEL
CASCADE 32
UP TO
UNITS
EZNAV INTUITIVE
CONTROL
SYSTEM
Navien Inc., 20 Goodyear, Irvine, CA 92618 800-519-8794 Navieninc.com
T H E L E A D E R I N C O N D E N S I N G T E C H N O L O G Y
NPE2-QF001-2203 ©2022 Navien Inc.
Dimensions
NPE-A2 NPE-S2
Specifications
Item NPE-150S2 NPE-180A2 NPE-180S2 NPE-210A2 NPE-210S2 NPE-240A2 NPE-240S2
Heat capacity (input)
Natural gas 18,000– 120,000
BTU/H
10,000–150,000 BTU/H 12,000–180,000 BTU/H 13,300–199,900 BTU/H
Energy factor UEF (for NG & LP) 0.93 0.95 0.96 0.95 0.96 0.95 0.96
Flow rate
(DHW)
35°F (19°C) temp rise
6.8 GPM
(26 L/m)
8.4 GPM (32 L/m) 10.1 GPM (38 L/m) 11.2 GPM (42 L/m)
45°F (25°C) temp rise
5.3 GPM
(20 L/m)
6.5 GPM (25 L/m) 7.8 GPM (30 L/m) 8.7 GPM (33 L/m)
67°F (36°C) temp rise
3.4 GPM
(13 L/m)
4.3 GPM
(16 L/m)
4.4 GPM
(17 L/m)
5.1 GPM
(19 L/m)
5.3 GPM
(20 L/m)
5.6 GPM
(21 L/m)
5.8 GPM
(22 L/m)
Dimensions 17.3" (W) x 27.4" (H) x 13.2" (D)
Weight 62 lbs (28 kg)
73 lbs (33 kg)
68 lbs (31 kg)
77 lbs (35 kg)
73 lbs (33 kg)
77 lbs (35 kg)
73 lbs (33 kg)
Installation type Indoor or outdoor wall-hung
Venting type Forced draft direct-vent
Ignition Electronic ignition
Water pressure 15–150 PSI
Natural gas supply pressure (from source)
3.5" WC–10.5" WC
Propane gas supply pressure (from source)
8" WC–13" WC
Natural gas manifold pressure (min-max)
-0.04" WC–
-0.40" WC
-0.03" WC–
-0.55" WC
-0.03" WC–
-0.76" WC
-0.03" WC–
-0.96" WC
Propane gas manifold pressure (min-max)
-0.03" WC–
-0.40" WC
-0.02" WC–
-0.55" WC
-0.02" WC–
-0.76" WC
-0.02" WC–
-0.96" WC
Minimum flow rate 0.5 GPM (1.9 L/m), < 0.01 GPM (0.04 L/m) option for "A2" models*
Connection sizes
Cold water inlet 3/4" NPT
How water outlet 3/4" NPT
Gas inlet 3/4" NPT
Power supply
Main supply 120V AC, 60 Hz
Maximum power consumption
200 W (max 2 A), 350 W (max 4 A) with external pump connected
Materials
Casing Cold rolled carbon steel
Heat exchangers Primary heat exchanger: stainless steel Secondary heat exchanger: stainless steel
Venting
Exhaust 2" or 3" PVC, CPVC, approved polypropylene and stainless steel 2" or 3" special gas vent type BH (Class II, A/B/C)
Intake 2" or 3" PVC, CPVC, approved polypropylene and stainless steel 2" or 3" special gas vent type BH (Class II, A/B/C)
Vent clearances 0" to combustibles
High elevations 10,100 feet for both NG or LP gas. Please refer to Installation Manual for additional details and instructions.
Safety devices Flame rod, APS, ignition operation detector, water temperature high limit switch, exhaust temperature high limit sensor, power surge fuse, burner high limit fuse, vent installation detector (VID)
* Available for NPE-A2 models configured in an optional ComfortFlow® recirculation mode. Energy consumption will increase when the system is configured for recirculation.
Navien reserves the right to change specifications at any time without prior notice.
Please refer to www.Navieninc.com to verify you have the most current information.
Accessories
NaviLink® Wi-Fi Control
PBCM-AS-001
H2Air® Kit AHU Optimizer
PNBD-000001
Remote Controller 30022717B
Plumb Easy Valve 3/4" with Relief Valve 30009323A
Plumb Easy 3 Valve Set for NPE-A2 30022163A
Plumb Easy Valve 3/4" with Relief Valve (designed to work with pipe cover) 30012581A
NaviCirc™ Recirculation Valve for NPE-A2
NaviCirc™
PFFW-SXX-001
NaviCirc™ Kit 30022965A
HotButton® Components
Wall Plate
GXXX001427
Push Button
GXXX001426
Residential Neutralizer 1 unit
GXXX001322
Residential Replacement Media
GXXX001323
Light Commercial Neutralizer
GXXX001324
Light Commercial Replacement Media
GXXX001328
Commercial Neutralizer
GXXX001325
Commercial Replacement Media
GXXX001329
2" and 3" Wall Flange and Vent Terminator Kit
2" Kit 30010747A
3" Kit 30003873B
PeakFlow S Scale Prevention System
GPWC1101AC001
PeakFlow S Replacement Filter
GWFC110GD001
Common Vent Collar Kit 30014367B
Includes Cascade Cable
GXXX000546
Cascade Cable
GXXX000546
External Pump Wire
GXXX001319
Vent Cap NPE-2 Series 30025801A
Pipe Cover NPE-2 Series 30025812A
Use with Isolation Valves 30012581A
Ready-Link® Rack
Base (V3)
GFFMKDIZUS-005
Add-on (V3)
GFFMKDIZUS-006
A B C D E F G
Air Intake Φ 2"
Exhaust Gas Vent Φ 2"
Hot Water Outlet Φ 3/4"
Gas Inlet Φ 3/4"
Recirculation Inlet Φ 3/4"
Condensate Outlet Φ 1/2"
Cold Water Inlet Φ 3/4"
Connection Size
Overhead View
Supply Connections
Front View
.4 in (6 m m
.8 in (7 m m in
(7 m m
6.7 in (170 mm)4.5 in (115 mm)
0.4 in
(1 m m
1.5 in (38 mm) 14.3 in (364 mm)
2.6 in
(6 m m
A B
.2 in (3 m m
2.3 in (60 mm)
3.0 in (77 mm)
8.3 in (212 mm)
17.3 in (440 mm)
2.4 in
(6 m m
2.4 in
(6 m m
C D E F G
6.
in (1 m m
A B C D E F
Air Intake Φ 2"
Exhaust Gas Vent Φ 2"
Hot Water Outlet Φ 3/4"
Gas Inlet Φ 3/4"
Condensate Outlet Φ 1/2"
Cold Water Inlet Φ 3/4"
Connection Size
Overhead View
Supply Connections
Front View
.4 in
(6 m m
.8 in (7 m m
.2 in (3 m m
2.
in (6 m m
C E FD
2.3 in (60 mm)
11.3 in (289 mm)
17.3 in (440 mm)
2.4 in
(6 m m
6.
in (1 m m in
(7 m m
6.7 in (170 mm)4.5 in (115 mm)
0.4 in
(1 m m
1.5 in (38 mm) 14.3 in (364 mm)
2.6 in
(6 m m
A B balfrey & johnston, inc.
Serving the Construction Industry Since 1959 13050 Northend Ave. Oak Park MI 48237 Phone: 313.864.2800 Fax: 313.864.7219 Branch Offices in Grand Rapids, Mt. Pleasant, Kalamazoo www.Balfrey-Johnston.com
Water Heater Comparison – Significant differences highlighted
Equipment Specified Model Total Requested Model Total Quantity Model Number BTU Input GPH Recovery Gallons Storage Efficiency - UEF
Warranty Information Heat Exchanger Warranty-Parts Warranty-Labor Warranty-Tank
Dimensions Height Width/Diameter Depth Cold Water Inlet Hot Water Outlet Gas Inlet Power Supply
Venting and Mounting Venting Mounting Rack & Manifold
Bock OT199N Navien NPE-240S2
60,000 - 199,000 13,300 - 199,900
229 GPH @ 100F Temp Rise 234 @ 100F Temp Rise
99 119 (selected by others)
96% Thermal Efficiency 0.96
3:1 Turndown Ratio 15:1 Turndown Ratio
5 Years 8 Years Dual Stainless Steel
5 Years 5 Years
1 Year 1 Year
5 Year (by selected tank mfg)
78.5" 28.8"
28" 17.3"
13.2"
1-1/2"" 3/4"
1-1/2" 3/4"
1/2" 3/4"
PVC, CPVC, PP PVC, CPVC, PP, SS
Wall Hung Wall Hung or Rack Mounted
Available
Why Navien Tankless Water Heaters?
Navien NPE-2 Series industry innovations:
Dual stainless steel heat exchangers resist corrosion better than copper
Energy efficiency ratings of up to 0.96 UEF
EZNav Multi-line control with built-in intuitive software
Capability to cascade up to 32 NPE-2 units
Common vent capability
Energy Star certification meeting strict EPA efficiency specifications
Navien tankless water heaters help solve application installation issues for:
Restaurants
Schools
Hotels
Medical
Industrial
Leisure
Multi-Family
Public Works Facilities
Navien tankless water heaters provide:
Reliability
Durability
Operating Efficiency
Energy and water conservation
Installation challenges solutions
Navien tankless features and benefits:
Industry leading warranty: 1 year labor, 3 year parts, 8 year heat exchanger
Life expectancy
Mounting options, wall or ReadyLInk rack and manifold system
Turndown ratios up to 15:1
Ease of change out as compared to tank type water heater
Connectivity via NavLink WiFi control
Navien Installations in Michigan
University of Michigan Student Housing
University of Michigan Football Stadium
Central Michigan University Medical School
Montross Schools
Carson City Correctional
Medilodge Assisted Living
Greenhaven Youth Home
Waltonwood Assisted Living
Rivers Edge Brewing
Western Golf & Country Club
On The Border Restaurant
Texas Roadhouse
Utica Minor League Baseball
X
A. Kindt 8/30/22
BIDDER’S SUBSTITUTION REQUEST FORM
Dimensional Metals, Inc. – 58 Klema Drive North – Reynoldsburg, OH 43068 – 800-828-1510
Cornerstone Architects
ARCHITECT
440 Bridge St. NW
STREET ADDRESS
Grand Rapids MI 49503
CITY STATE ZIP
(616)-774-0100
PHONE FAX
Mitchell State Park Campground, South Toilet Shower Bldg 1006177281
PROJECT NAME PROJECT NUMBER
We submit for your Consideration the following Product in addition to the specified Product for the above Project:
As per Section No. 074113
Paragraph No.
2.1
Specified Product - Standing Seam Metal
Roof Panel
We submit our IL2016 Panel System.
(Attached you will find technical data and any laboratory tests, if applicable.)
The following changes will take place to the Drawings and Specifications for the proposed substitution’s proper installation:
A. Dimension changes in drawings - None B. DMI will or will not pay for changes to the design, including engineering and detailing costs caused by the substituted product – Not applicable
C. Effects on other installers - None D. Differences between our panel and panel specified – none E. Warranty differences - None
The undersigned states that the function, appearance, and quality are equivalent or superior to the specified Product.
Submitted By:
Jeff Earley 8/30/2022
SIGNATURE DATE
Dimensional Metals, Inc
COMPANY NAME
58 Klema Drive North
STREET ADDRESS
Reynoldsburg OH 43068
CITY STATE ZIP
419.889.8427 866.863.4334
PHONE FAX
FOR ARCHITECT’S USE ONLY
- ACCEPTED - ACCEPTED AS NOTED - NOT ACCEPTED - TOO LATE
BY DATE
ADDITIONAL REMARKS
PUBLISHED IN ADDENDUM NUMBER -
DYNACLAD® BOX GUTTERINTER-LOCK IL20
ARCHITECTURAL PANEL
Please consult DMI for applicability of test reports for your project.
800.828.1510 • www.dmimetals.com • sales@dmimetals.com
Expansion Clip
INTER-LOCK IL20 is an architectural panel which is snapped together during installation.The panel is an integral interlocking system by design which installs in one direction from a given starting point. A double male starter panel is available (for a minimal setup fee) and may be installed in the middle of a roof area to achieve a symmetrical layout. Inter-Lock is a very flexi-ble panel which works well with a wide range of building designs.
Uses & Applications Product uses include roofs wtih slopes as low as 3:12, vertical fascia, equipment screens, mansards, and wall panels. This system may also be installed on tapered roof areas.
Advantages ·Factory Applied Non-Curing Sealant - for superior watertightness ·Engineered Snap-Together design - for easy installation ·Symmetrical Visual Aesthetics - providing non-directional appearance ·Expansion Clips - allows for thermal expansion and contraction ·Continuous Interlocking Seam - no seam disengagement ·Anti-Siphoning Seam Desgin - prevents water infiltration ·Continuous Roll Formed Lengths - eliminates need for panel lap joints (4’ min. panel length) ·Total System Warranties available - for total confidence
Performance Tested ·UL-580 Wind Uplift ·ASTM E1592 Uniform Static Air Pressure ·ASTM E331 Water Penetration ·ASTM E283 Air Leakage
Seam Cross Section
SEALANT
IN SEAM
PANEL CLIP
FASTENER
STRIATED PANEL PROFILE
(STANDARD)
12", 16" or 17.75”
1.75"
12302020
Since 1988 Dimensional Metals, Inc. (DMI) has specialized in the manufacturing of architectural metal roof and wall panel systems as well as fabricated architectural sheet metal for the construction industry. We are backed by decades of proven metal envelope design, dependable Technical Field Services, and an Engineering Department delivering sustainable solutions. You are sure to find the product that will best enhance your design.
Project Name:
Architect:
Installing Contractor:
General Contractor:
Specification Section:
Custom Colors Available
Colors shown are samples and may vary slightly from actual material. Please consult DMI Color Chart for stocking color availability.
†Metallic colors are directionally sensitive and therefore entire roof areas should be ordered at once time to ensure uniformity.
Double Male Panel is not available in Metallic Colors.
*Brite Red has a clear coat. **Premium colors carry an upcharge.
WHITE
SRI = 85
COBALT BLUE
SRI = 20
PUTTY
SRI = 77
SANDSTONE
SRI = 77
DOVE GREY
SRI = 61
PATINA COPPER
SRI = 58
BRITE RED*
SRI = 44
BEIGE
SRI = 53
STONE
SRI = 49
BROWN
SRI = 25
SLATE GREY
SRI = 47
CHAMPAGNE
SRI = 51
TERRA COTTA
SRI = 43
MUSKET GREY
SRI = 35
SEAPORT
SRI = 35
COLONIAL RED
SRI = 34
METALLIC COPPER
SRI = 49
BURGUNDY
SRI = 34
HEMLOCK GREEN
SRI = 31
EVERGREEN
SRI = 28
SPARTAN BRONZE
SRI = 30
METALLIC SILVER
SRI = 53
CHARCOAL GREY
SRI = 31
SLATE BLUE
SRI = 34
HARTFORD GREEN
SRI = 26
DARK BRONZE
SRI = 27
AGED COPPER
SRI = 43
MATTE BLACK
SRI = 29
ROYAL BLUE
SRI = 27
LEAF GREEN
SRI = 31
CLASSIC BRONZE
SRI = 29
WEATHERED ZINC
SRI = 37
DynaClad®
PVDF Color Chart
P re m iu m C ol or s
M et al lic C ol or s
INTER-LOCK IL20
800.828.1510 • www.dmimetals.com • sales@dmimetals.com
Standard Finishes (N/A on Mill Finishes) DynaClad® PVDF:
Acrylic Coated Galvalume (Acrylume®) Clear Anodized Aluminum
Premium Finishes*
*Premium Colors subject to minimum quantities, extended lead times and upcharges.
Consult DMI for details.
DynaClad® Metallic PVDF:
DynaClad® Brite Red PVDF DynaClad® Cobalt Blue PVDF DynaClad® Standard Color PVDF w/ Clearcoat:
DynaClad® Premium Color PVDF w/ Clearcoat:
Custom Color:
Warranty Finish DynaClad® Paint Finish Galvalume® 20 Year - 6 Month (Substrate) Aluminum Sheet 2 Year (Substrate) Watertight DynaClad® Metal Roofing System:
DynaClad® Metal Roofing System NDL:
Panel Width 12” 16” 18” (17.75”)
Clip Expansion
Stiffener Profile
Substrate 24 ga. Galvalume®
22 ga. Galvalume®
.032 Aluminum
.040 Aluminum
Embossed:
Consult DMI for minimum quantities, upcharges, set up fees and extended lead times
16 oz. Copper 20 oz. Copper
Dimensional Metals, Inc. offers a wide range of innovative roofing and water-proofing products for the building industry. With more than 25 years of field experience, DMI products are engineered for superior performance and ease of installation.
DESCRIPTION
DynaClad® Ultra HT Wind & Water Seal™ is a self-adhering waterproof-ing underlayment composed of a non-slip, cross-laminated polymer film, laminated to a high temperature, aggressive rubberized asphalt adhesive.
A protective split release liner is removed during installation. Ultra HT is engineered for use under metal roofing systems. Ultra HT adheres aggress-ively to most clean, dry substrates including Rigid Insulation, Plywood and Metal Deck. Prime masonry, weathered OSB, exterior grade gypsum roofing products and aged metal surfaces as necessary to achieve good adhesion. Product self-seals around punctures such as screws and nails.
This advanced system limits damage caused by water penetration or leaks.
Ultra HT is ideal for secondary water resistance and prevents damage from ice dams and wind-driven rain.
USES
Whole-roof underlayment for metal roofing. Use at eaves, valleys, rakes and around roof penetrations for protection against ice dams and wind-driven rain. For roof slopes less than 3:12 DMI Requires a full layer of Ultra HT on the entire field of the roof.
FEATURES
Ultra HT offers the contractor and property owner these extra features:
• Uniform thickness for dependable protection
• Self-seals around fasteners including screws and nails
• High elongation, flexible, accommodates expansion and contraction of the substrate
• Compatible with most construction sealants and primers
• Eliminates leaks - multiple layers of protection seals out water
• Rubberized asphalt won’t crack or dry - protects against ice, wind and rain
• Aggressively adheres - sticks to plywood, metal and most other building materials for ease of application.
• Non-slip surface and overlap guide lines for easy installation
• White, heat reflective surfaces allows for adhesion directly to Extruded and Poly-Isosyanurate Insulation
INSTALLATION
• Surface must be clean, dry and free from oil
• Apply in clear, dry weather at 50°F or above
• Clean, dry wood and metal surfaces do not require priming
• Prime masonry, weathered OSB, exterior grade gypsum roofing products and aged metal surfaces as necessary
- masonry must be fully cured
• Minimum 3” side laps and 6” end laps
• Apply uniform pressure with a 2 - 3” hand roller to the seams and overlaps
• Do not expose to direct sunlight for more than 90 days
• Do not install over solvent-based sealants unless fully cured
- active solvents may liquify bottom adhesive surface
• Installer is responsible for compatibility with caulks and sealants
• Material folded over a roof edge cannot be left exposed, fasten every 6” and cover
DynaClad® Metal Roofing System Limited Warranty Ultra HT Wind & Water Seal™ qualifies and is covered under DMI’s DynaClad® Metal Roofing System Limited Warranty.
For the most current Installation Instructions, Warranties, Technical Specifications and Approvals, visit www.dmimetals.com.
58 Klema Drive North - Reynoldsburg, OH 43068 tel: 800.828.1510 - fax: 740.927.3319 web: www.dmimetals.com -
TECHNICAL SPECIFICATIONS
Property Test Method Result
Material Thickness ASTM D 5147 45 Mils Nom.
Flexibility @ -20°F ASTM D 1970 Pass
Vapor Permeance ASTM E 96 <0.02
Nail Sealability ASTM D 1970 Pass
Adhesion to Plywood @ 75°F ASTM D 903/1970 >12 lbs/ft
Adhesion to Plywood @ 40°F ASTM D 903/1970 >2 lbs/ft
PRODUCT DATA
Installation Temperature Range >50°F
Material Color White
Roll Width 36”
Roll Length 67 ft
Carton Weight 52 lbs
Rolls per Carton 1
Area per Carton 200 sqft
Cartons per Pallet 30
Max Temp. 250°F
Results based on modi�ed ASTM standards
DYNACLAD®
DIMENSIONAL METALS, INC.
Proven ∙ Dependable ∙ Sustainable Metal Envelope Systems Since 1988
WHITE
SRI = 85
COBALT BLUE
SRI = 20
PUTTY
SRI = 77
SANDSTONE
SRI = 77
DOVE GREY
SRI = 61
PATINA COPPER
SRI = 58
BRITE RED*
SRI = 44
BEIGE
SRI = 53
STONE
SRI = 49
BROWN
SRI = 25
SLATE GREY
SRI = 47
CHAMPAGNE
SRI = 51
TERRA COTTA
SRI = 43
MUSKET GREY
SRI = 35
SEAPORT
SRI = 35
COLONIAL RED
SRI = 34
METALLIC COPPER
SRI = 49
BURGUNDY
SRI = 34
HEMLOCK GREEN
SRI = 31
EVERGREEN
SRI = 28
SPARTAN BRONZE
SRI = 30
METALLIC SILVER
SRI = 53
CHARCOAL GREY
SRI = 31
SLATE BLUE
SRI = 34
HARTFORD GREEN
SRI = 26
DARK BRONZE
SRI = 27
AGED COPPER
SRI = 43
MATTE BLACK
SRI = 29
ROYAL BLUE
SRI = 27
LEAF GREEN
SRI = 31
CLASSIC BRONZE
SRI = 29
WEATHERED ZINC
SRI = 37
D I M E N S I O N A L M E TA LS , I N C .
† Metallic colors are directionally sensitive and therefore entire roof areas should be ordered at one time to ensure color uniformity.
*Brite Red has a clear coat. ** Premium colors carry an upcharge. SRI = Solar Reflectance Index.
Colors shown are samples and may vary slightly from actual material. CUSTOM COLORS ARE AVAILABLE
DynaClad®
PVDF Color Chart
P re m iu m C ol or s
M et al lic
C ol or s
Till 3457 35 Chips @ 1.25”w X 1”h Dorn Color, Inc.
2020-01
N A T I O N A L R O O F I N G C O N T R A C T O R S A S S O C I A T I O N
D I M E N S I O N A L M E TA LS , I N C .
X LA, LB, LC, LD, and LE approved subs. OA not approved.
A. Kindt 9/2/22
Beginning of Run Housing Style B48 Nominal 48" housing
Middle Fixture(s) Housing Style (replace "x" with qty) (x)/M48 Nominal 48" housing(s)
Ending of Run Housing Style E48 Nominal 48" housing
SPECIFICATIONS
HOUSING: Marine grade aluminum. Extruded body with die-cast end caps. Housing, with end caps, post assembly TGIC polyester powder coat finished – 5-step pre-treatment. Each linear run of luminaires consists of one Beginning of Run Luminaire (B), one or multiple Middle Luminaire(s) (M), and one End of Run Luminaire (E). Specify and/or order systems per linear run (i.e. (1)B48, (5)M48, (1)E48). NOTE: Contact factory for custom lengths.
REFLECTOR: Full reflector/wire cover – 97% reflectivity.
LENS: UV-stabilized, high impact extruded pearlescent polycarbonate. Smooth exterior, linear prismatic interior. Nominal thickness .156". Lens securely positioned in body channels and end caps.
Lens locked in place with tamper-resistant stainless steel Torx® with center pin fasteners and sealed with closed cell gaskets.
END CAPS: Marine grade die-cast aluminum. Three styles available: Flat, Rounded and Reveal. Conduit and ”Wiremold™ ready” knockouts visible only from interior of end cap (Flat and Rounded styles only).
HARDWARE: Four stainless steel, tamper-resistant Torx® fasteners secure lens in housing body's lens channel. Electrical Quick Connector supplied (Specify Circuit Qty, see below).
ELECTRICAL: Available 3500K, 4000K and 5000K color temperatures, 82 CRI. 120-277VAC and 347VAC, 50/60Hz electrical input with serviceable high power factor electronic, constant-current driver (<20% THD, >0.95 PF). Standard 0-10V dimming with 1-100% range and dim-to-dark capabilities; maximum driver source of 330μA. Consult factory for flourescent option.
SENSOR & CONTROLS: Optional sensor available with compatible third party controls. To see the full list of compatible controls, click here.
INSTALLATION: Standard six-point mounting per fixture required for Peace of Mind Guarantee®.
PHOTOMETRICS: Photometry tested to the IESNA LM-79-08 standard by an ILAC/ISO17025 accredited laboratory. For additional photometric data, please go to www.kenall.com.
WARRANTY: limited ten (10) year LED warranty. Peace of Mind Guarantee against breakage.
LISTINGS: Luminaire is certified to UL standards by Intertek Testing Laboratories for non-IC and Wet Location installations. IP64 rating per IEC60598 – ceiling mount. Corner, horizontal wall and pendant mount installation – Damp Location only. ADA compliant. Suitable for use as a raceway. Suitable for use in continuous row.
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. ©2022 Kenall Mfg.Co.
Continuous Row Joiner Band
MILLENIUM STRETCH™
MLHA8 SERIES – STRAIGHT CONTINUOUS RUN
PRODUCT FEATURES:
» Surface mount – ceiling or wall; 8"×48"
» Continuous row mount luminaires
» Peace of Mind Guarantee® against breakage
» ADA compliant
Rounded End Cap
Flat End Cap
Reveal End Cap
End Caps R Rounded F Flat RV Reveal
Finish MW Matte White MB Matte Black LG Light Gray CC Custom Color (Consult Factory)
Lens PP Pearlescent Polycarbonate
Lamp Type 45L35K 45 Watt 3500K LED 45L40K 45 Watt 4000K LED 45L50K 45 Watt 5000K LED 67L35K 67 Watt 3500K LED 67L40K 67 Watt 4000K LED 67L50K 67 Watt 5000K LED 90L35K 90 Watt 3500K LED 90L40K 90 Watt 4000K LED 90L50K 90 Watt 5000K LED
Driver Type DCC Dimming Constant Current Driver
Voltage DV 120-277 Volts 347 347 Volts
Options LEL Integral 8.4W Emergency Battery Backup (45L max, 0oC minimum operating temperature, n/a with 347V) 1RW First Isolated Raceway CDF Captive Diffuser Fasteners DL Damp Location (Interior use NO gasketing) FS Single Fuse & Holder NAT Natatorium Environment Option PH Phillips Head Fasteners PM§ Pendant Mount (Max. 3/8NPT stems by others;
damp only) XC Auxiliary Circuit NLW 2700K White LED Night Light (n/a with 347V) NLA Amber LED Night Light (n/a with 347V)
Accessories CMB§ Corner Mount Bracket (Must be ordered with DL Option) 9500 Torx® Screwdriver D-0552 Torx Driver Bit (Required for CMB Option)
§ PM and CMB not available in conjunction
PROJECT INFORMATION
Job Name
Fixture Type
Catalog Number
Approved by
ORDERING INFORMATION (Ex: MLHA8S-B48-2/M48-E48-R-MW-PP-45L40K-DCC-DV-FS)
Model Finish Lens Lamp Type DriverBegin. Hsg. End Cap Voltage
MLHA8S
Options
B48 Mid. Hsg.
/M48 End. Hsg
E48 DCC
Accessories
MLHA8S-012522
IP64LED ADA
MLHA8S
24" sections available
FF Flat
MWW Matte Wh
PPP Pearlescent Polycarbonate p y 45L35KK K 45 Watt 3500K LED
DCCC Dimming Constant Current Driver
4758lms 49W
MLHA8S B24 4/M48 E48 F MW PP 45L35K DCC DV
DVV 120-277 Volts
TYPE LA
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. ©2022 Kenall Mfg.Co.
MILLENIUM STRETCH™
MLHA8 SERIES – STRAIGHT CONTINUOUS RUN
For additional photometry, go to www.kenall.com
Nominal Four Foot Fixture Legend End Cap A B C D E F R 49.93 49.34 49.93 46.31 22.50 45.00 F 49.32 49.34 49.32 46.31 22.50 45.00
RV 49.02 49.34 49.02 46.31 22.50 45.00
JOINER BAND –
REQUIRED FOR
ROW MOUNTING
(SUPPLIED)
CORNER MOUNT
8.00"
4.00"
Optional Isolated Raceway
6.89"
6.89"
5.60"
5.60"
DIMENSIONAL DATA
PERFORMANCE
Model: MLHA8-48-F-MW-PP-45L40K-DCC-DV
Maximum Candela = 1568 Located At Horizontal Angle = 15, Vertical Angle = 5
1 - Vertical Plane Through Horizontal Angles (15-195) (Through Max. Cd.)
2 - Horizontal Cone Through Vertical Angle (5) (Through Max. Cd.)
Initial Delivered Lumens
Lamp Type @ 25°C Efficacy (lm/W)
Input Power (W)
Drive Current (mA)
Estd. L70 LED Life (Hrs)
45L35K 4,758 97 49 100 150,000
45L40K 5,072 104 49 100 150,000
45L50K 5,072 104 49 100 150,000
67L35K 7,284 100 73 75 150,000
67L40K 7,765 106 73 75 150,000
67L50K 7,765 106 73 75 150,000
90L35K 9,252 94 98 100 150,000
90L40K 9,864 101 98 100 150,000
90L50K 9,864 101 98 100 150,000
Information above is valid for the recommended Type PP lens type and is subject to change without notice.
Visit www.kenall.com for IES files and additional information.
MLHA8S-012522
45L35K 4,758 97 49 10
Rounded End Cap
Flat End Cap
Reveal End Cap
PRODUCT FEATURES:
» Surface mount – wall or ceiling; nominal 8"×24", 8"×36" 8"×48", 8"×72", 8"×96"
» Extruded aluminum housing with decorative end caps
» Peace of Mind Guarantee® against breakage
» ADA compliant
Length 24 2' 36 3' 48 4' 72 Two 3' (factory connected) 96 Two 4' (factory connected)
End Caps F Flat R Rounded RV Reveal
Finish LG Light Gray MB Matte Black MW Matte White CC Custom Color (Consult Factory)
Lens CP• Clear Polycarbonate PP Pearlescent Polycarbonate
Lamp Quantity (Cross Section)• 1 One 2 Two 3 Three (T8 or T5 only) www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. ©2022 Kenall Mfg.Co.
Lamp Type 2' Lengths 25L35K 25 Watt 3500K LED 25L40K 25 Watt 4000K LED 25L50K 25 Watt 5000K LED 14 F14T5 (rapid start only) 17 F17T8 24I F24T5HO (rapid start only)
3' Lengths 21 F21T5 (rapid start only) 25 F25T8 39 F39T5HO (rapid start only)
4' Lengths 45L35K 45 Watt 3500K LED 45L40K 45 Watt 4000K LED 45L50K 45 Watt 5000K LED 67L35K 67 Watt 3500K LED 67L40K 67 Watt 4000K LED 67L50K 67 Watt 5000K LED 90L35K 90 Watt 3500K LED 90L40K 90 Watt 4000K LED 90L50K 90 Watt 5000K LED 28 F28T5 (rapid start only) 32 F32T8 54 F54T5HO (rapid start only) 54A F54T5HO amalgam (rapid start only)
Ballast/Driver Type IS Instant Start Electronic <10% THD (T8) RS Rapid Start Electronic <10% THD (T8,T5,T5HO) SB Specified Ballast DCC Dimming Constant Current (LED)
Circuit Quantity (n/a with LED) 1 One 2† Two (2 Ballast minimum)
Voltage 120 120 Volts 277 277 Volts 347 347 Volts DV 120-277 Volts
Options ELI P•§ 500 Minimum Lumen Battery Pack (90 Minutes; 32°F Starting Temp) PELI W•§1100 Minimum Lumen Battery Pack (90 Minutes; 32°F Starting Temp) LEL Integral 8.4W Emergency Battery Backup (4' length only, 45L max, 0oC minimum operating temperature, n/a with 347V) CDF Captive Diffuser Fasteners DL Damp Location (Interior use NO gasketing) FS Single Fuse & Holder (one per circuit) NAT§ Natatorium Environment Option PH Phillips Head Fasteners PM§‡ Pendant Mount (Max. 3/8NPT stems by others;
damp only) UC§ • Uplight Component (Pendant Mount only;
stems by others; damp only) MS Motion Sensor (2' and 4' LED only) (n/a with 347 Voltage Option) NLW∞ 2700K White LED Night Light NLA∞ Amber LED Night Light
Accessories CMB‡ Corner Mount Bracket
(Must be ordered with DL Option) 9500 Torx® Screwdriver D-0552 Torx Driver Bit (Required for CMB Option)
TekLink TL50* TL50 Control System (n/a with 347V) (Click here for specifications) TL100 TL100 Control System (Click here for specifications)
Please consult Kenall Applications when ordering controls. Mounting heights above 14' may require alternate sensing technology.
Controls Kit < > Factory Assigned Internal Code
† n/a on 2' T5/T5HO or 3' T5HO fixtures with EL, PEL or TN options
I n/a with 347V P 2' Fixtures have minimum 350-450 lumen battery pack W n/a on 2' fixtures § n/a with 3 lamps
• n/a with LED Lamp Type ‡ PM and CMB not available in conjunction
* LED only. N/A with with MS or CMB options.
N/A with 72" or 96" length.
∞ LED only. n/a with 347V
MILLENIUM STRETCH™
MLHA8 SERIES
SPECIFICATIONS
HOUSING: Marine grade aluminum. Extruded body with die-cast end caps. Housing, with end caps, post assembly TGIC polyester powder coat finished – 5-step pre-treatment. See Ordering Information for standard, optional, architectural and custom finishes.
REFLECTOR: Full reflector/wire cover – 92% reflectivity.
LENS: UV-stabilized, high impact extruded clear or pearlescent polycarbonate. Smooth exterior, linear prismatic interior. Nominal thickness .156". Lens securely positioned in body channels and end caps. Lens locked in place with tamper-resistant stainless steel Torx® with center pin fasteners and sealed with closed cell gaskets.
END CAPS: Marine grade die-cast aluminum. Three styles available: Flat, Rounded and Reveal. Conduit and ”Wiremold™ ready” knockouts visible only from interior of end cap (Flat and Rounded styles only).
SOCKETS: Shock-resistant sockets with internal locking collar to ensure positive lamp retention.
HARDWARE: Stainless steel, tamper-resistant Torx fasteners secure lens in housing body’s lens channel (four on 24", 36", and 48" housings; eight on 72" and 96" housings).
ELECTRICAL: LED: Available 3500K, 4000K and 5000K color temperatures, 82 CRI. 120-277VAC and 347VAC, 50/60Hz electrical input with serviceable high power factor electronic, constant-current driver (<20% THD, >0.95 PF). Standard 0-10V dimming with 1-100% range and dim-to-dark capabilities, maximum driver source of 330μA. Optional embedded microwave motion sensor (MS) has factory default settings of 20 minute time out, dims down to 30%. LF: Class P ballasts. Fluorescent electronic 120/277/347 and dual voltage ballasts high power factor.
INSTALLATION: Standard four-point (24" housing), six-point (36" and 48" housing) and twelve-point (72" and 96" housing) mounting required for Peace of Mind Guarantee®. LED product ambient temperature is -30°C to 40°C, unless otherwise noted.
SENSOR & CONTROLS: Optional sensor available with compatible third party controls. To see the full list of compatible controls, click here.
TEKLINK™ TL50: An independent lighting control system embedded in the luminaire, featuring its own occupancy sensor, daylight harvesting and adjustable time-out/dimming settings.
TEKLINK™ TL100: Centralized, wired zonal occupancy and closed-loop daylight harvesting control system. TL100 controllers are standalone devices and ordered separately for luminaire.
Click here for specifications.
PHOTOMETRICS: Photometry tested to the IESNA LM-79-08 standard by an ILAC/ISO17025 accredited laboratory. For additional photometric information, go to www.kenall.com.
WARRANTY: Limited ten (10) year warranty for LED Lamps. Peace of Mind Guarantee against breakage.
LISTINGS: Luminaire is certified to UL standards by Intertek Testing Laboratories for non-IC and Wet Location installations. IP64 rating per IEC60598 – ceiling mount. Corner, horizontal wall and pendant mount installation – damp location only. ADA compliant.
IP64LED ADA
ORDERING INFORMATION (Ex: MLHA8-48-F-MB-PP-45L40K-DCC-DV-FS-9500)
PROJECT INFORMATION
Job Name
Fixture Type
Catalog Number
Approved by
Model
MLHA8
Finish Lens Lamp Type Ballast/DriverLength End Cap Voltage Controls KitOptions TekLinkAccessoriesLamp Qty Circuit Qty
MLHA8-072722
TYPE LB
488 4'
FF Flat
MWW Matte White
PPP Pearlescent Polycarbonate g 45L35KKK 45 Watt 3500K LED
DVV 120-277 Volts
11 One
11 One
DCCC Dimming Constant Current (LED)
4758LMS
49W
MLHA8 SERIES
MILLENIUM STRETCH™
For additional photometry, go to www.kenall.com
CORNER MOUNT BRACKETCROSS SECTION/DETAILS MOUNTING HOLES
DIMENSIONAL DATA
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. ©2022 Kenall Mfg.Co.
Nominal Three Foot Fixture Legend LMP End Cap A B C D T8 R 38.524 34.312 16.500 33.000 T8 F 34.312 34.312 16.500 33.000
T8 RV 40.632 34.312 16.500 33.000
T5 R 36.751 32.540 16.344 32.688 T5 F 35.535 32.540 16.344 32.688
T5 RV 38.859 32.540 16.344 32.688
Nominal Two Foot Fixture Legend LMP End Cap A B C D T8 R 26.524 22.312 N/A 21.000 T8 F 25.308 22.312 N/A 21.000
T8 RV 28.632 22.312 N/A 21.000
T5 R 24.940 20.728 N/A 20.875 T5 F 23.724 20.728 N/A 20.875
T5 RV 27.048 20.728 N/A 20.875
Nominal Four Foot Fixture Legend LMP End Cap A B C D
T8/LED R 50.524 46.312 22.500 45.000
T8/LED F 49.308…
This is the start of the file's text. The full file is on GovTribe.