Revised_12-18-2009-Drawings.pdf
PDF 8 MB Posted
- Solicitation number
- AB1330-10-RP-0005
About this file
Revised Plans dated 12/18/09
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXIT
M A
X
M
IN
6" 1' - 0"
M A
X
EQ EQ
FIRE ALARM (COMBINATION SPEAKER AND STROBE)
FIREMAN'S PHONE JACK
WALL MOUNTED EXIT LIGHT
LIGHT SWITCH AND DIMMER
THERMOSTAT OR OTHER
CONTROL DEVICE
ELECTRIC, TELEPHONE,
OR DATA RECEPTACLE
FINISHED FLOOR
M
IN
M
IN
M A
X
6"8"
1' - 7" TO 1'-9"
MIN. MAX.
BOTTOM OF MIRROR
FINISHED FLOOR
M A
X
M A
X
2' - 0"
11" MIN.
M
IN
M
IN
8" MIN.
M A
X
T O
IL
E
T
A C
C E
S S
IB
L E
T O
IL
E
T
S T
A N
D A
R D
U R
IN
A
L
A C
C E
S S
IB
L E
U R
IN
A
L
S T
A N
D A
R D
B A
B Y
C H
A N
G
IN
G S
T A
T
IO
N
L A
V A
T O
R Y
P A
P E
R
T
O W
E L
D
IS
P E
N S
E R
T
R A
S H
R E
C E
P T
A C
L E
S A
N
IT
A R
Y N
A P
K
IN
V E
N D
IN
G
M A
X
S E
A T
C O
V E
R D
IS
P
E N
S E
R
S A
N
IT
A R
Y N
A P
K
IN
D
IS
P O
S A
L
M A
X
M A
X
P A
Y T
E L E
P H
O N
E (A
C C
E S
S
IB
L E
P A
Y T
E L E
P H
O N
E (S
T A
N D
A R
D
M A
X
30" TO TOP OF BED WHEN OPEN
F
IR
E E
X T
IN
G
U
IS
H E
R C
A B
IN
E
T
F .E
D R
IN
K
IN
G
F O
U N
T A
IN
(A
C C
E S
S
IB
L E
P A
P E
R
T
O W
E L
D
IS
P E
N S
E R
T
R A
S H
R E
C E
P T
A C
L E
T O
IL
E
T T
IS
S
U E
D
IS
P E
N S
E R
M A
X
M A
X
S P
O U
T H
E
IG
H T
M A
X
3' - 0" MIN.
1' - 6"
S O
A P
D
IS
P E
N S
E R
M A
X
F
IR
E H
O S
E R
E A
L C
A B
IN
E
T
3' - 6" MIN.
5' - 0" MIN.
3' - 0" MAX.
1' - 0" MAX. 6"
M
IR
R O
R
/1
M A
X
TOILET PARTITION
2' - 0" 2' - 0"
36" UTILITY SHELF
(10801)
FRP WALL
PROTECTION (06640)
MOP SINK
PLUMBING FIXTURE
RE: MEP
CONT. SEALANT3
1' - 0"2"2" 4' - 0"
COORDINATE WITH
MANUFACTURER
HALL LANTERN
CALL BUTTONS
TACTILE LEVEL INDICATOR
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790 Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No
Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
GDS Engineering 9201 E. 63rd Street, Suite 100 Raytown, MO 64133 Tel. 816-358-1790 Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816-931-6655 F: 816 931 9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P. 619.299.6690 F. 619.299.5513
Specifications/Labs/Security:
HDR, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
U.S. Department of Commerce, NOAA
Southwest Fisheries Science Center La Jolla, California
/1
/2
:5 :0
P
M
A020
PROJECT STANDARDS
0207-3075
October 9, 2009
NOAA La Jolla Laboratory Replacement Project
Final Construction Documents
3/8" = 1'-0"
E1 MISC HEIGHTS
3/8" = 1'-0"
E4 ACCESSIBLE HEIGHTS
A1 1/2" = 1'-0"
FIXTURE HEIGHT GUIDELINES
1/2" = 1'-0"
TYPICAL JANITORS' CLOSETE15
3/8" = 1'-0"
E5 TYPICAL ELEVATOR DOOR
3" = 1'-0"
1 RESTROOM DOOR SIGNS
3" = 1'-0"
2 TYPICAL ROOM WALL SIGNS
3" = 1'-0"
3 RESTROOM WALL SIGNS
3" = 1'-0"
4 EXIT/EXIT ROUTE SIGNS
3/8" = 1'-0"
5 SIGNAGE MOUNTING HEIGHTS &
LOCATION
Number Revision Description Date
1 Revised 12/18/2009
9'-6"
(OBSTACLE ON BOTH SIDES)
8'-0" WIDE
NOTE :
PAINT, DIRECTIONAL ARROWS AT DRIVEWAY ENTRY AND
PARKING AS REQUIRED BY THE CITY OF SAN DIEGO
NOTE :
SEE SITE PLAN FOR SPECIFIC PARKING DIMENSIONS.
9'-0"
(OBSTACLE ON 1 SIDE)
STALL ADJACENT TO WALL, COLUMN,
OR OTHER IMMOVABLE OBJECT.
TYPICAL STALL
4" WIDE
PAINTED
STRIPES
TYP.
(02741)
MIN 6' LONG WHEEL
STOP WHERE
INDICATED ON PLAN
SEE DETAIL 5/A021
8'-3" FOR RETAIL SALES AND
DINING AND DRINKING
ESTABLISHMENTS.
FACE OF CURB OR WALL
FACE OF OBSTACLE
8'-0"9'-0"9'-0"9'-0" 5'-0"
NO
PARKING
NO
PARKING
DISABLED PARKING SPACE MUST PERMIT USE OF EITHER CAR DOORS.
A PARKING BUMPER IS REQUIRED WHEN NO CURB OR BARRIER IS PROVIDED WHICH WILL
PREVENT ENCROACHMENT OF CARS OVER THE ADJOINING ACCESSIBLE ROUTE.
WHEELCHAIR USERS MUST NOT TO BE FORCED TO GO BEHIND PARKED CARS OTHER THAN THEIR
OWN TO ACCESS AN ADJOINING ACCESSIBLE ROUTE.
THE MAXIMUM SURFACE SLOPE WITHIN THE DISABLED PARKING SPACE AND ADJACENT ACCESS
AISLE MAY NOT EXCEED 2% IN ANY DIRECTION.
CURB RAMPS MAY NOT ENCROACH INTO THE REQUIRED DIMENSIONS OF DISABLED PARKING
SPACES OR ADJACENT ACCESS AISLES.
ACCESS AISLE (LOADING/UNLOADING AREA) MUST CONNECT TO AN ACCESSIBLE PATH OF TRAVEL
TO THE FACILITY.
1.- 2.-
3.-
4.-
5.-
6.-
STANDARD ACCESSIBLE STALL VAN
ACCESSIBLE
STALL
36" SQ
INTERNATIONAL
SYMBOL OF
ACCESSIBILITY
STALL EMBLEM
(TYP) PER
DETAIL 3/A021
(02741)
ACCESSIBILITY
SIGN @ EACH
SPACE PER
DETAIL 4/A021
12" MIN.
HIGH
LETTERS AT
EVERY
ACCESSIBLE
AISLE (02741)
ACCESSIBILITY NOTES:
STRIPES AT
36" OC (02741)
WHEEL STOP
PER DETAIL
5/A021
2" TYP.
3'-0" ON PAVEMENT
O
N P
A V
E M
E N
T
PAINT SYMBOL AND
BORDER WHITE (02741)
BLUE FIELD COLOR SHALL BE
EQUAL TO COLOR NO. 15090 IN
FEDERAL STANDARD 595B. (02741)
EMBLEM MUST BE LOCATED IN STALL SO THAT IS VISIBLE
BY A TRAFFIC ENFORCEMENT OFFICER WHEN A VEHICLE IS
PROPERLY PARKED IN THE SPACE (CENTERED AT
ENTRANCE TO STALL RECOMENDED)
SHALL BE IN ACCORDANCE WITH
CBC SEC. 1129B.4
8"
(N
.T .S
L E
T T
E R
S
2"
M A
X
1/4"x8"x8" GALVANIZED STEEL PLATE
W/(4)1/2" � x 4" EXPANSION BOLTS (05500)
FINISH CONCRETE (03300)
3/16"
2"x2" GALVANIZED STEEL TUBE
PAINT SYMBOL AND LETTERS WHITE
PLACARD TO READ:
AT STD. ACCESSIBLE STALL: 'ACCESSIBLE'
AT VAN ACCESSIBLE STALL:
'VAN ACCESSIBLE'
BLUE FIELD COLOR SHALL BE
EQUAL TO COLOR NO. 15090 IN
FEDERAL STANDARD 595A
INTERNATIONAL SYMBOL OF ACCESSIBILITY
ALTERNATE AT PLANTER
CONDITION - IMBED TUBE 18" INTO
12" DIA X 24" DEEP CONCRETE
FOOTING - TAPER TOP TO DRAIN
AWAY FROM POST SHOWN DASHED
FINISH GRADE AT ALTERNATE
PLANTER CONDITION
VAN
ACCESSIBLE
E Q
E
Q
/4
/4
7 1/2"
2"3" 1/4"
2" 1/4"
6'-0"
6"
N.T.S.
6"
T O
F R
O N
T O
F P
A R
K
IN
G S
P A
C E
CROSS SECTION
PLAN VIEW
#5 REBAR 18" LONG
#3 REBAR CONTINUOUS
PRECAST CONCRETE WHEEL
STOP (02751)
1" DIAM. HOLE
M
IN
17" MIN.
SIGN SHALL MEET THE
REQUIREMENTS FOR CBC
SECTION 1129B.5
UNAUTHORIZED
VEHICHLES PARKED IN
DESIGNATED ACCESSIBLE
SPACES NOT DISPLAYING
DISTINGUISHING PLACES
CARDS OR LICENSE
PLATES ISSUED FOR
PERSONS WITH
DISABILITIES MAY BE
TOWED AWAY AT
OWNERS EXPENSE.
TOWED VEHICLES MAY BE
RECLAIMED AT
_________OR BY
TELEPHONING
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790 Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No
Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
GDS Engineering 9201 E. 63rd Street, Suite 100 Raytown, MO 64133 Tel. 816-358-1790 Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816-931-6655 F: 816 931 9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P. 619.299.6690 F. 619.299.5513
Specifications/Labs/Security:
HDR, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
U.S. Department of Commerce, NOAA
Southwest Fisheries Science Center La Jolla, California
/1
/2
:5 :5
P
M
A021
PARKING & MISC.
DETAILS
0207-3075
October 9, 2009
NOAA La Jolla Laboratory Replacement Project
Final Construction Documents
3/4" = 1'-0"
1 TYPICAL STRIPING PLAN
1/8" = 1'-0"
2 ACCESSIBLE PARKING SPACE
DESIGN
1" = 1'-0"
3 INTERNATIONAL ACCESSIBILITY
SYMBOL
3" = 1'-0"
4 ACCESSIBLE PARKING SIGN
1 1/2" = 1'-0"1 A111
5 CONCRETE WHEEL STOP
1 1/2" = 1'-0"
6 UNAUTHORIZED PARKING SIGNAGE
Number Revision Description Date
1 Revised 12/18/2009
%%UNOTES:
LATERAL FORCE BRACING MEMBERS SHALL BE A MIN. OF 6" FROM ALL HORIZ. PIPING OR DUCT
WORK NOT PROVIDED W/BRACING RESTRAINTS FOR HORIZ. FORCES.
BRACING WIRES SHALL SUPPORT A DESIGN LOAD THE GREATER OF 200 POUNDS OR THE ACTUAL LOAD, WITH A SAFETY FACTOR OF TWO (2x).
FASTEN SEISMIC RESTRAINT CLIPS TO FIXTURE WITH HEX WASHER HEAD, SHEET METAL SCREWS, MINIMUM EA. TWO PER FIXTURE. TYPICAL.
#12 GA. SAFETY WIRE TIED TO SEISMIC CLIPS OR SAFETY WIRE SUPPORT HOLES AND FASTEN TO
BLDG. STRUCTURE MINIMUM (2) EA. SAFETY WIRES PER FIXTURE
EXPOSED HEAVY DUTY T-BAR CEILING SYSTEM. TYPICAL.
CONNECT (2 MIN.) VERTICAL 12 GA. WIRES ATTACHED TO OPPOSING CORNERS ALONG THE
FIXTURE'S DIAGONAL. THESE WIRES MAY BE SLACK.
PROVIDE PERIMETER VERTICAL SUPPORT WIRES @ 8" MAX. AWAY FROM FACE OF WALL.
LIGHT FIXTURE OR
MECHANICAL
FIXTURE
LIGHTING FIXTURES WEIGHING 56 POUNDS OR MORE SHALL BE SUPPORTED FROM STRUCTURE
DIRECTLY ABOVE WITH 8 GA. WIRE OR APPROVED ALTERNATE SUPPORT.
INSTALL PER MFG'R RECOMMENDATIONS.7
COMPRESSION STUD PER
DETAIL 4/A022 (09511)
12 GA HANGER WIRE PER
DETAILS 3 & 4/A022 (09511)
LINE OF STRUCTURE
ABOVE
MIN. 12 GAUGE x 1-1/2" x 1-1/2" x 1-1/2" W METAL
ANGLE ATTACHED WITH .170" POWDER
ACTUATED FASTENER, TYPICAL. (09511)
(2) .170" P.A.F. AT
COMPRESSION
STRUT WEB,
TYPICAL (09511)
%%UPOWDER ACTUATED FASTENERS: (PAF)
RAMSET FASTENERS INSTALLED WITH POWDER ACTUATED TOOL, ICBO #1639 OR EQUAL.
FASTENERS SHALL BE RAMSET 3310 LOW-VELOCITY FASTENERS AND HAVE .170" SHANK DIAMETER WITH STEEL DISK OR WASHERS AT THE HEAD. MINIMUM PENETRATION IN CONCRETE = 1-1/4". ICBO ALLOWABLE LOADS FOR NORMAL WEIGHT CONCRETE WITH f'c = 2000 PSI (TABLE 1, PAGE 2, ICBO
#1639, APRIL 1990): TENSION = 165 LBS, SHEAR = 225 LBS.
%%uTYP. HANGER WIRE & COMPRESS. STUD
%%uATTACHMENTS FOR CLG SUPPORTS
HEAVY DUTY CROSS RUNNER (09511)
NOTE: LOCATE SEISMIC BRACING
WIRES & STUDS AS NOT TO
EXCEED 12'-0" IN EACH DIRECTION,
WITH THE FIRST POINT WITHIN 6'-0"
FROM EACH WALL.
12 GA. VERTICAL HANGER WIRE @
4'-0" O.C. EACH WAY WITH MIN. 4
TIGHT TURNS WITHIN THE FIRST
1-1/2" AT BOTH ENDS OF WIRE,
TYPICAL. ANCHOR TO STRUCTURE
PER 2/A022 (09511)
(2) SPLAYED 12 GA. SEISMIC
BRACING WIRES, PER 4/A022
(09511)
SEE FINISH SCHEDULE & SPECS
FOR TYPE OF CEILING TILE,
TYPICAL (09511)
(2) 3-5_
" 20 GA. METAL STUD @
45° ANGLE SEISMIC BRACING IN
OPPOSITE DIRECTION OF
SEISMIC WIRES (ONE IN EACH
DIRECTION); 1-5_
" FLANGE & 1_
LIP MIN. PER DETAIL 4/A022 (09111)
HEAVY DUTY MAIN RUNNER (09511)
2" MAX
M A
X
HEAVY DUTY MAIN RUNNER
HEAVY DUTY CROSS TEE
(2) SPLAYED 12 GA. SEISMIC
BRACING WIRES @ 45 DEGREE
ANGLES, EACH WITH MIN. 4 TIGHT
TURNS WITHIN THE FIRST 1-1/2" AT
BOTH ENDS OF WIRE, TYPICAL.
ANCHOR TO STRUCTURE PER
2/A022 (09511)
25 GA. METAL STUD COMPRESSION
STRUT WITH 1-5/8" FLANGE & 1/2"
LIP, MIN. @ 12'-0" O.C. EACH WAY.
ANCHOR TO STRUCTURE PER
DETAIL 2/A022 (09111)
(2) 3-5_
" 20 GA. METAL STUD @
45° ANGLE SEISMIC BRACING IN
OPPOSITE DIRECTION OF
SEISMIC WIRES (ONE IN EACH
DIRECTION); 1-5_
" FLANGE & 1_
LIP MIN. (09111)
A022
A022
8"
-1
/ 2
HANGER WIRE (TYP.) (09511)
MAIN OR CROSS RUNNER (09511)
MIN. 4 TIGHT TURNS
LAY-IN CLG. PANEL TYP. (09511)
CLOSURE ANGLE.
REFER TO NOTE 1.
NOTE 1. ONE END OF CEILING GRID SHALL BE POP RIVETED TO THE CLOSURE
ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL BE
ATTACHED BY SLOTTED CLIP, ESR-1308. AS SHOWN ABOVE DETAIL AND SEE
LOCATION DIAGRAM
7/8"
CEILING GRID PLAN
@ EDGE TRACK
CONNECTION TO
WALL
SLOTTED CLIP POP RIVETS
PLAN VIEW
2" BEAM END RETAINING CLIP JOINS
(BERC2), PER ESR-1308 (09511)
SLOTTED CLIP
U O
N
F L U
S H
W
IT
H C
E
IL
IN
G
A T
L A
B
5"
5/8" TYPE 'X' GPBD (09250)
LAY-IN CEILING
PANELS (09511)
EXISTING
CEILING HGT.
5/8" TYPE 'X' GPBD (09250)
PER PLAN
MTL STUDS BRACE TO STR.
ABOVE (09111)
20 GA. 3 5/8" METAL STUDS,
UNITED METALS ICBO #4943
(09111)
REFER TO DETAIL 5/A022 SIM.
P E
R P
L A
N
PER PLAN
P E
R P
L A
N
EQ. EQ.
20 GA. 3 5/8" MTL STUDS (09111)
CEILING HT.
PER PLAN
5/8" TYPE 'X' GPDW, TYP. V (09250)
LIGHTING WHERE OCCURS (16511)
DIAGONAL BRACE (09111)
LC
GALV. BRACING WIRES
GALV. HANGER WIRES,
EA. MAIN RUNNER
FURRING CHANNEL
MAIN RUNNER
ITEM
#8 GA. ON GRID
8'-0" X 8'-0"
#8 GA.
@ 4'-0" O.C.
7/8" HAT CHANNEL- 25 GA.
@ 16" O.C.
1 1/2" CRC - 16 GA.
@ 48" O.C. MAX.
SEISMIC BRACING STUDS & WIRES
(ONE IN EACH DIRECTION) @ 45°
ATTACHED TO MAIN RUNNER W/
ANCHOR TO STRUCTURE. SEE
SIMILAR DETAIL 4/A022 (09511)
HANGER WIRES ATTACHED TO MAIN
RUNNER W/ ANCHOR TO STRUCT.
(09511)
HEAVY DUTY MAIN RUNNER (09511)
1/2" OR 5/8" GPDW
FURRING CHANNELS (09511)
1 1/2" CRC - 16 GA.
@ 48" O.C. MAX
3/4" CRC - 16 GA.
@ 12" O.C.
PLASTER CEILING CEILING
#8 GA.
@ 4'-0" O.C.
#8 GA. ON GRID
8'-0" X 8'-0"
CONCEALED HINGE (09250)
KEY LOCK (09250)
A A
TYPE 'X GYP. BD. (09250)
METAL STUD (09111)
ADHESIVE MASTIC
METAL DOOR AND FRAME (09250)
BEADED FRAME TO RECEIVE
DRYWALL CEMENT (09250)
ELEVATION
SECTION
0.6096M
[2'-0"] (V.I.F.)
.6
M
[2
V .I .F
WIDTH
11/4"
.3
M
IN
STUDS
RIGID DIAGONAL BRACING
METAL STUD CHART
FOOTNOTES:
(1)
(2)
(1)
(1)(2)
TYP. 35/8" STUD (09111)
#8 S.M.S. @ 12" O.C.
7'-0" 5 8 0.42
7'-8" 5 8 0.46
22'-9" 5 8 1.36
(NESTED)
3 " x 20GA.
" x 25GA
" x 20GA. 2 - 3
L MAX Ry
12'-0" 4'-0"
C E
N T
E R
L
IN
E O
F P
R O
J E
C T
O R
P E
R P
L A
N C
E N
T E
R O
N D
E S
K L
A Y
O U
T T
Y P
E Q
E
Q
PROVIDE MOUNTING SUPPORT FOR FUTURE
PROJECTOR (O.F.O.I.) WITHIN INDICATED
2'-0" X 4'-0" ZONE, VERIFY WITH OWNER.
SPRINKLER/FIRE PROTECTION CONTRACTOR TO
COORDINATE RELOCATION OF EXISTING SPRINKLER HEADS
SO AS NOT TO INTERFERE WITH PROJECTOR LOCATIONS.
1.
2.
DUPLEX
RECEPTACLE
PER
ELECTRICAL
BRACKET- ANCHOR PER MANUF.
RECOMMENDATION. (11132)
SCREEN CASE (11132)
PROJ. SCREEN (11132)
VIEWING SURFACE (11132)
CEILING PER PLAN
PROVIDE BACKING PER MANUF. SPEC.
WALL TYPE-SEE FLR. PLAN & WALL
TYPE LEGEND (TYP.)
10"
10' - 0" AFF
3 5/8" MTL. STUD, PER
PARTITION TYPES (09111)
5/8" GYP. BD. (09250)
RECESSED FLUORESCENT,
LINEAR W/ ACRYLIC LENS, SEE
ELECTRICAL DWG'S (16511)
6" MTL. STUD, PER PARTITION TYPES
(09111)
CMU WALL (04810)
FLOOR ABOVE, SEE
STRUCTURAL
6" MTL. RUNNER (09111)
/4
10"
3 5/8" MTL. STUD, PER
PARTITION TYPES (09111)
SURFACE MOUNTED
FLUORESCENT W/ ACRYLIC LENS
(16511)
5/8" GYP. BD. (09250)
3 5/8" MTL. RUNNER, PER
PARTITION TYPES (09111)
9' - 0" AFF
9' - 0"
3 5/8" MTL. STUD, PER
PARTITION TYPES (09111)
5/8" GYP. BD. (09250)
7/8" HAT CHANNEL (09111)
3 5/8" MTL. RUNNER
(09111)
COVE LIGHT FIXTURE
(16511)
HARD LID CEILING @ 9'-0"
AFF. (09250)
A022
TYP.
HARD LID COVE CEILING
@ 10'-0" AFF. (09250)
.1 m
10"
0.254 m
ACOUSTICAL CEILING
PANEL W/ KNIFE
EDGE TRIM (09511)
CL-1
CUSTOM TRANSITION
TRIM, COLOR TO
MATCH KNIFE EDGE
(09511)
PER RCP
PER RCP
SUSPENSION WIRE (09511)
ACOUSTICAL CEILING PANEL
W/ KNIFE EDGE TRIM (09511)
PER RCP
PER RCP
5/8" GYP. BD. (09250)
3 5/8" MTL. STUD PER
PARTITION TYPES (09111)
CL-1
SUSPENSION WIRE (09511)
A022
MTL. STUD BRACE TO STR. ABOVE
LAY-IN CLG. PANEL AND SUPPORTS
(09511)
INTERIOR STOREFRONT SYSTEM PER
SPEC. (08411)
REFER TO DETAIL 5/A022
CONC. SLAB ABOVE PER STRUCTURAL
(03300)
5/8" GYP. BD. TO STRUCTURE ABOVE.
(09250)
INSULATION WHERE AS INDICATED BY
WALL TYPE (07210)
MTL. STUD BRACE TO
STRUCTURE ABOVE (09111)
5/8" GYP. BD. TO 6" ABOVE CLG.
TYP. (09250)
LAY-IN CLG. PANEL AND
SUPPORTS (09511)
INTERIOR STOREFRONT SYSTEM
PER SPEC. (08411)
REFER TO DETAIL 5/A022
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790 Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No
Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
GDS Engineering 9201 E. 63rd Street, Suite 100 Raytown, MO 64133 Tel. 816-358-1790 Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816-931-6655 F: 816 931 9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P. 619.299.6690 F. 619.299.5513
Specifications/Labs/Security:
HDR, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
U.S. Department of Commerce, NOAA
Southwest Fisheries Science Center La Jolla, California
/1
/2
:5 :5
P
M
A022
CEILING DETAILS
0207-3075
October 9, 2009
NOAA La Jolla Laboratory Replacement Project
Final Construction Documents
12" = 1'-0"5 A023
2 FIXTURE SUPPORT DETAIL
12" = 1'-0"
3 TYP SUSPENDED ACT CEILING GRID
12" = 1'-0"
4 RIGID SUSPENDED CEILING GRID
COMPRESSION & SEISMIC BRACING
12" = 1'-0"14 A023
5 CEILING DETAIL (PROPRIETARY)
3" = 1'-0"1 A125
6 GPDW. FILLER STRIP
1 1/2" = 1'-0"
7 HEADERS AT HALLWAYS
12" = 1'-0"
8 RIGID GYPSUM SUSPENDED
CEILING SYSTEM
1 1/2" = 1'-0"1 A125
16 TYP. RECESSED DRYWALL ACCESS
PANEL
1" = 1'-0"1 A105
10 RECESSED LIGHT FIXTURE IN SOFFIT
1" = 1'-0"13 A022
11 COVE LIGHT FIXTURE
1" = 1'-0"1 A105
12 SOFFIT CONDITION @ STAIR
1" = 1'-0"1 A105
13 ENLARGED COVE LIGHT RCP - LEVEL
P
3" = 1'-0"1 A125
14 CEILING SECTION A
3" = 1'-0"1 A126
15 CEILING SECTION B
12" = 1'-0"
9 METAL STUD CHART
12" = 1'-0"1 A135
20 PROJECTOR LOCATION
12" = 1'-0"1 A125
19 PROJECTION SCREEN INSTALLATION
1 1/2" = 1'-0"1 A125
18 CIELING AT STOREFRONT HEADER &
FULL HT. WALL.WINDOW
3" = 1'-0"18 A022
17 CEILING AT STOREFRONT HEADER /
PART. HT. WALL
Number Revision Description Date
1 Revised 12/18/2009
1'-6" 1'-6" 1'-6"
LUMINAIRE
PER ELEC.
DWGS. (16511)
3 5/8" MTL.
STUD PER
PARTITION
TYPES (09111)
/4
.0 m
0.457 m 0.458 m 0.457 m
11' - 0" A.F.F.
BLACK ACOUS.
FELT ADHERED
TO TOP OF SLAT
CLG. MEMBERS.
WOOD CROSS PIECE
GRILLE CLG. SYSTEM
PER SPEC (09547)
5/8" GYP. BD. (09250)
12' - 8" A.F.F.
CEILING SLAB PER STRUCTURAL
(03300)
P-1.2 TYP.
1'-1" 5"
0.330 m 0.127 m0.127 m
5" 1'-1"
0.127 m 0.330 m
/4
.0 m
FRAMED GYP. BD. SOFFIT ON
METAL STUDS, HEIGHTS PER
RCP (09111; 09250)
CONCRETE BEAM PER
STRUCTURAL DWGS. (03300)
CONT. MTL. CHANNEL ATTACHED
TO STRUCTURE PER DETAILS.
(09111)
BLACK ACOUSTICAL FELT
ADHERED TO TOP OF SLAT CLG.
MEMBERS, EXTEND UNDER
FRAMED SOFFIT. (09547).
CL-3 WOOD CROSS PIECE GRILLE
SUSPENDED CEILING SYSTEM
(09547)
P-1.2 TYP.
11' - 0" A.F.F.
T-BAR MAIN SUPPORTS AND
SUSPENSION WIRES ATTACHED
TO CROSS PIECES AT 24" O.C.
TYP. (09547)
O.C. TYP.
1'-0"
MAX. CANT.
6" 3/4"
BLACK CROSS PIECE BACKER @
12" O.C. PER MANUF.(09547).
0.305 m 0.152 m 0.019 m
MAIN SUPPORTS @ 24" O.C.
PERPENDICULAR TO WOOD GRILLE.
ATTACH PANELS TO MAIN SUPPORTS
PER MANUF. DTLS. (09547)
CL-3 WOOD CROSS PIECE GRILLE
CLG. 2.25" x 5/8" WOOD SLATS @ 1
23/32" O.C. (PER MANUF.) W/ BLACK
ACOUSTICAL FABRIC ABOVE
(09547).
+/- 1 3/4"+/- 4 1/2"+/- 7 1/2"
0.306 m
PANEL WIDTH (7 MEMBERS PER LINEAR FT)
1'-0"
0.044 m0.115 m0.191 m
MAINS PARALLEL TO GRILL AT
EITHER SIDE OF LUMINAIRE, TYP.
(09547)
LUMINAIRE PER ELEC (16511).
ALIGN W/ TOP FACE OF CLG.
GRILLE.
CROSSPIECE BACKERS (BEYOND)
@ 12" O.C., BLACK TYP (09547).
4"
/4
0.016 m
5/8"
0.102 m
.0 m
CL-3 WOOD CROSS PIECE GRILLE
CLG. BEYOND, FINISH ALL EXPOSED
SIDES TYP. (09547).
CROSSPIECE BACKERS UNDER
CLG. MAINS EA. SIDE OF LIGHT
FIXTURE PER CLG. MANUF. DETAILS
(09547).
STOREFRONT WINDOW
SYSTEM (08411).
REFER TO DETAIL E9/A314.
MECHO SHADE SYSTEM. GC.
TO COORDINATE SIZE OF
OPENING WITH PRODUCT
MANUF.
BRACKET-ANCHOR PER
MANUF. RECOMMENDATION.
(12494)
CEILING HEIGHT, PER PLAN
CL-3 @ CEILING & WALL.
SECURE ACOUSTICAL FABRIC
TO CLG APPLICATION ONLY
(09547).
CONCRETE BEAM PER
STRUCTURAL DWGS. (03300)
11' - 0" A.F.F.
MTL ANGLE FASTENED TO WALL
APPLICATION (09511).
FRAMED WALL PER PLAN DTL.
THIS SHEET.
MAIN SUPPORTS @ 24" O.C.
PERPENDICULAR TO WOOD
GRILLE. ATTACH PANELS TO
MAIN SUPPORTS PER MANUF.
DTLS (09547).
SUSPENSION WIRE (09511,
09547).
1'-0"
SECURE LAST PANEL TO FRAMED
SOFFIT AS REQ'D (09547)
CL-3 WOOD CROSS PIECE GRILLE CLG.
(PER MANUF.) W/ BLACK ACOUSTICAL
FABRIC ABOVE (09547) SUSPENDED FROM
STRUCTURE ABOVE PER DTLS.
V E
R
IF
Y R
E Q
U
IR
E D
C L E
A R
A N
C E
CONC. SLAB ABOVE PER STRUCTURAL
(03300)
T-BAR MAIN AT 24" O.C. ALIGNED WITH
CEILING CROSS PIECES. CROSS PIECES
TO BE ATTACHED TO T-BAR PER MANUF.
DTLS. (09547)
DIAGONAL SUPPORTS TO STRUCTURE
ABOVE AS REQ'D. (09511).
CONT. MTL. CHANNEL ATTACHED TO
STRUCTURE ABOVE PER DETAILS (09111)
P-1.2 TYP.
A022
SIM
A022
SIM
STEEL BEAM BEYOND PER STRUCTURAL
(05120)
1'-0"
8"
0.202 m
3/4"
0.020 m
/4
/2
.0 m
.0 m
FRAMED GYP. BD. SOFFIT ON
METAL STUDS (09111; 09250)
CONT. MTL. CHANNEL ATTACHED
TO STRUCTURE PER DETAILS.
(09111)
LUMINAIRE PER ELEC. DWGS.
(16511)
BLACK ACOUSTICAL FELT
ADHERED TO TOP OF SLAT CLG.
MEMBERS, EXTEND UNDER
FRAMED SOFFIT. (09547).
1x WOOD SURROUND TO MASK
LUMINAIRE ATTACHED TO FRAMED
SOFFIT. WOOD SPECIES & FINISH
TO MATCH CL-3, PAINT INTERIOR
SIDE WHITE.
CL-3 WOOD CROSS PIECE GRILLE
SUSPENDED CEILING SYSTEM
(09547)
1'-6"
0.457 m
P-1.2 TYP.
5" CROSS PIECE @ EXT. EDGE OF
CEILING SYSTEM, TYP (09547),
SPECIES / FINISH TO MATCH CLG.
CL-3. ATTACH TO SOFFIT
FRAMING W/ SLIP CONNECTION.
0.330 m
1'-1"
ELEV. PER RCP
ELEV. PER RCP
3/4"
MTL. STUDS TO STRUCTURE
ABOVE (09111)
5/8" GYP. BD. FULL HT.
COORDINATE REQ'D OPENING
WITH MEP (09250)
FRAMED SOFFIT PER PLANS
(09511) REFER TO RCP FOR
ELEVATION.
CL-3 WOOD CROSS PIECE
GRILLE CEILING SYSTEM PER
SPECS. (09547)
0.019 m
/4
.0 m
MAX. CANTILEVER
6 1/4"
0.158 m
BLACK ACOUSTICAL FELT PER
SPECS. (09547)
P-1.2 TYP.
V1V2
/4
PROVIDE A MECHO
SHADE SYSTEM @
EACH EXTERIOR
WINDOW, UNLESS
NOTED BY OTHERS.
SEE SPECIFICATIONS
AND DETAILS (12494).
W SECTION RE:
STRUCTURAL (05500)
DIFFUSER & DUCTING
PER MECH (15855;
15815)
GLAZED ALUMINUM
CURTAIN WALLS (08911)
FRAMED GYP. BD.
SOFFIT ON METAL
STUDS (09111; 09250).
CL-3 SUSPENDED
WOOD CROSS PIECE
GRILLE SYSTEM
(09547)
A023
LOW PROFILE LIGHT
EA. SIDE OF COLUMN
PER ELEC. (16511)
0.457 m 0.508 m
STRUCTURAL STEEL
BEYOND(05500)
STRUCTURAL COLUMN
BEYOND.
.0 m
.2 m
A313 C1
SIM
1'-6" 1'-8"
Y5
0.203 m 0.330 m
CONT. MTL CHANNEL
(09111)
12' - 0 3/4" A.F.F.
12' - 8" A.F.F.
FRAMED SOFFIT PER PLAN
(09111)
SUSPENDED CL-3 WOOD
CROSS PIECE GRILLE
BEYOND(09547)
LUMINAIRE PER ELEC.
(16511) BEHIND WOODEN
LIGHT BOX SEE 3/A023
8" 1'-1"
4 7/8" 1'-9"
0.124 m 0.533 m
11' - 0" A.F.F.
5" 3"
/4
.3 m
SLAB ABOVE PER STRUCTURAL (03300)
CONT. MTL. CHANNEL ATTACHED TO
STRUCTURE ABOVE (09111)
LUMINAIRE PER ELEC. WHERE
OCCURS (16511)
SOFFIT FRAMING (09111)
ELEV. PER RCP
ELEV. PER RCP
BRACING AS REQ'D. (09111)
5/8" GYP. BD. TYP. (09250)
MTL. STUD DIAGONAL CROSS BRACE TO
STRUCTURE ABOVE (09111)
6"
3/4"
4 7/8"
3/4"
6"
0.152 m
0.019 m
0.124 m
0.019 m
0.152 m
.1 m
WALL TO EXTEND 6" ABOVE CLG. (09111)
HANGER WIRES (09511,09547)
T-BAR MAIN 6" FROM END MAX. (09511,
09547)
CL-3 WOOD CROSS PIECE GRILLE CLG.
PER SPEC (09547)
WALL PER PLAN (09111)
A023
TYP.
WOOD ACOUSTIC
PANEL "Z" CLIP
INSTALL.
CL-3 @ CEILING & WALL.
SECURE ACOUSTICAL
FABRIC TO CLG
APPLICATION ONLY (09547).
/8
E Q
/8
2"
E Q
DOOR TO HAVE CLADDING
TO MATCH & ALIGN W/ WALL
1 5/8"
.0 m
E Q
.0 m
0.051 m
E Q
0.041 m
METAL STUD WALL PER WALL
TYPES
5/8"3/4"
0.019 m 0.016 m
PANEL WIDTH
1'-0"
0.305 m
MTL. STUD DIAGONAL CROSS BRACE
TO STRUCTURE ABOVE (09111)
WALL PER PLAN (09111)
WALL TO EXTEND 6" ABOVE CLG. (09111)
HANGER WIRES (09511)
T-BAR MAIN 6" FROM END MAX. (09511,
09547)
CL-3 WOOD CROSS PIECE GRILLE CLG.
PER SPEC (09547). LOCATION OF PANEL
RELATIVE TO WALL WILL VARY. VERIFY
WITH RCP, SPACING EA. SIDE OF WALL TO
BE BETWEEN 1/2" AND 3/4", TYP.
.1 m
LINE OF CLG BEYOND. (09547)
1 1/2"2
/4
0.038 m
.0 m
CL-3 @ CEILING & WALL.
SECURE ACOUSTICAL FABRIC TO
CLG APPLICATION ONLY (09547).
STOREFRONT DOOR HEAD (08411)
MT-1 CLADDING FACE TO ALIGN
w/ AP-2 PANEL SYSTEM
.1 m
MULTIPURPOSE
ROOM
W2 W1W2
A314
E9
SIM
A022
TYP.
.1 m
8' - 10" A.F.F.
9' - 0" A.F.F.
11' - 0" A.F.F.
ACOUSTICAL PANEL CEILINGS (09511)
FRAMED GYP. BD. SOFFIT ON
METAL STUDS (09111; 09250).
EXTERIOR PLASTER SOFFIT
(09220)
ALUMINUM WINDOW SYSTEM
(08411)
BATT INSULATION (07210).
10' - 2" A.F.F.
11' - 1" A.F.F.
9' - 0" A.F.F.
A022
TYP.
DUCT WORK PER MECH.
(15815)
LINEAR DIFFUSER PER
MECH. (15855)1'-0" 5"
0.305 m 0.127 m
EQ. EQ.
MECH SHADE (12494)
EXTERIOR PLASTER SOFFIT
(09220)
ALUMINUM WINDOW
SYSTEM (08411)
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790 Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No
Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
GDS Engineering 9201 E. 63rd Street, Suite 100 Raytown, MO 64133 Tel. 816-358-1790 Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816-931-6655 F: 816 931 9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P. 619.299.6690 F. 619.299.5513
Specifications/Labs/Security:
HDR, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
U.S. Department of Commerce, NOAA
Southwest Fisheries Science Center La Jolla, California
/1
/2
:5 :5
P
M
A023
CEILING DETAILS
0207-3075
October 9, 2009
NOAA La Jolla Laboratory Replacement Project
Final Construction Documents
1 1/2" = 1'-0"1 A115
1 CL-3 @ CENTER LIGHT COVE SLOT
1 1/2" = 1'-0"1 A115
2 CL-3 @ DROPPED SOFFIT
3" = 1'-0"1 A115
6 CL-3 LINEAR LUMINAIRE
ATTACHMENT
3" = 1'-0"1 A125
17 TYP. MECHO SHADE DETAIL @
OFFICES
3" = 1'-0"12 A023
4 CL-3 @ WALL / CLG. TRANSITION
1 1/2" = 1'-0"1 A125
5 CL-3 AT STEP IN CEILING HEIGHT
1 1/2" = 1'-0"8 A023
3 CL-3 @ PERIMETER LIGHT COVE
3" = 1'-0"1 A125
7 CL-3 FLUSH W/ SOFFIT
1" = 1'-0"1 A115
8 CL-3 @ EXT. WND
1 1/2" = 1'-0"1 A115
9 CL-3 SOFFIT AT ENTRANCE
1 1/2" = 1'-0"1 A115
18 SOFFIT TRANSITION
1 1/2" = 1'-0"1 A125
10 CL-3 AT PERPENDICULAR
INTERSECTING WALL
3" = 1'-0"1 A135
12 SECTION @ MULTIPURPOSE RM.
3" = 1'-0"1 A125
11 CL-3 AT PARALLEL INTERSECTING
WALL
3" = 1'-0"10 A165
13 SECTION @ MULTIPURPOSE RM.
1" = 1'-0"1 A135
14 SOFFIT AT EXTERIOR WINDOW
1 1/2" = 1'-0"1 A145
15 SOFFIT AT EXTERIOR WINDOW
Number Revision Description Date
1 Revised 12/18/2009
SCALE:
8'-6"
U.O.N. RCP
0'-0"
FINISHED FLOOR
2'-10"
MAX. COUNTER HT.
3'-4"
MAX. MIRROR HT.
8"
MIN.
KNEE CLR.
17" MIN.
DEPTH
M
IN
T
O E
C L
R . 2
M
IN
M
IN
22"
COUNTER
/4
A023
A023
A023
A0233/4" = 1'-0"
WALL SECTION @
LAVATORY RESTROOM COUNTER
TILE BASE PER FINISH DWGS. (09310)
MIRROR MOUNTED STAINLESS
STEEL L TRIM @ PERIMETER - 1_
FRONT EDGE (08830)
GYP. BD. CEILING (09511) ON
SUSPENDED FRAME STRUCTURE
(09111)
DASHED LINE INDICATES AREA
OF REQUIRED ADA CLEARANCE
WALL CONSTUCTION PER FLOOR PLANS
SEE DETAIL
FOR NOTES ON COUNTER SUPPORTS
PROVIDE ONE PIECE INSULATION
@ EXPOSED PIPES, COLOR TO
MATCH ADJACENT WALL, OR PER
ARCHITECT (10801)
BLOCKING BEHIND
COUNTER EDGE
AS REQUIRED
(06402)
2'-1"
LIGHT FIXTURE, PER ELECTRICAL
DWG'S (16511)
ADA CODE REQ.:INSTALL DIM.:
ES-2
F
U L
L T
IL
E
S
TILE AS SHOWN PER ELEV.T-4
PER ELEV. PROVIDE LAMINATE
CABINET W/ TRASH COUNTAINER
TO FIT , CONCEALED HINGE
STAIN. ST. LOCK, RAISED OF
FLOOR 6", TILE UNDERNEATH
LP-4
EXPANSION JOINT SEALANT (07920)
GROUT (09310)
TILE BACKING PANEL (09250)
CERAMIC TILE (09310)
THIN SET MORTAR (09310)
INTEGRAL COVE BASE TILE (09310)
GROUT (09310)
CERAMIC TILE (09310)
THIN SET MORTAR (09310)
WATERPROOF MEMBRANE (09310)
L A
P W
P
1" RADIUS
WALL LINE
WRAP SHEET VINYL
FLOORING UP WALL (09652)
SOLID BACKING TO
SUPPORT COVE (09652)
FLOOR LINE
METAL TRIM (09652),
COLOR TBD BY
ARCHITECT.
B A
NOTE: REFER TO ELEVATIONS TO
DETERMINE WHICH DETAIL
APPLIES
GROUT (09310)
CERAMIC TILE (09310)
THIN SET MORTAR (09310)
SOLID SURFACE
COUNTER W/CONT.
BACKPLASH (06615)
EXPANSION JOINT
SEALANT (07920)
COUNTER PER
FINISH PLANS (06402)
MIRROR (08830)
MIRROR
MOUNTED PER
MANUFACTURER'S
REQUIREMENTS
(08830)
EXPANSION JOINT
SEALANT (07920)
.1
M
[4
.0
M
[2
COUNTER HT.
SEE COUNTER DETAILS
3" x 3/8" x 2'-3" STL. � BOLTED
BETWEEN BACK TO BACK STEEL
STUDS (WELDED TO NOTCHED
STEEL ANGLE) (05500)
2" x 11_ " x 1_
" LLV STEEL ANGLE;
LENGTH OF ANGLE AS REQUIRED
TO SUPPORT COUNTERTOP (05500).
** SPACING SHALL BE ONE COUNTER
SUPPORT ASSEMBLY FOR EVERY 40"
OF UNSUPPORTED COUNTER -
ASSEMBLY TO BE CENTERED
BETWEEN LAVS AND TO BE PLACED
AT UNSUPPORTED ENDS.
C O
U N
TER
A
S
SPEC
IF
IE
D
IN
FIN
IS
H D
W G
S
16 GA. STUDS (09111)
D R
YW
ALL
WELD
2"
SUBSTRATE (09250)
CERAMIC TILE (09310)
CORNER TILE PIECE TO BE USED
AT ALL OUTSIDE CORNERS (09310)
M
A X
A T
C O
M P
R E
S S
E D
C A
R P
E T
/S H
E E
T V
IN
Y
L B
E L O
W T
H R
E S
H O
L D
F
L O
A T
S L A
B A
S N
E C
E S
S A
R Y
I N
A L L A
R E
A S
R E
C E
IV
IN
G S
H E
E T
V
IN
Y L
/4
VERIFY
/2
M
A X
/4
CONCRETE (03300)
THINSET CERAMIC TILE (09310)
CARPET (09680; 09681) / SHEET VINYL FLOORING (09652)
MAX 1/2" HIGH MARBLE
THRESHOLD SET IN THINSET
MORTAR
DOOR PER SCHEDULE (08111;
08130; 08211)
DOOR FRAME BEYOND (08111;
08130; 08211)
GYP. BD. PARTITION BEYOND
CERAMIC TILE (09310)
CERAMIC TILE PER
INTERIOR
ELEVATIONS (09310)
THICK SET MORTAR BED (09310)
BEVELED CERAMIC TILE CURB
(ADAAG SECTION 4.21.7)
(09310)
MAX SLOPE 1:50
SHOWER
1 / 2
M A
X D
R O
P
THICKSET TILE
WTI-1 (PER SPEC) (09310)
THINSET TILE
FTI-1 (PER SPEC) (09310)
EXPANSION JOINT SEALANT (07920)
BOND BREAKER TAPE (07920)
THICK SET MORTAR BED (09310)
WATERPROOF MEMBRANE (09310)
D E
P R
E S
S
IO
N I N
S L A
B W
H E
R E
O C
C U
R S
P E
R S
T R
U C
T D
W G
S
LIQUID APPLIED WATERPROOFING
ANTI-FRACTURE MEMBRANE. APPLY
FLOOR TO CEILING (09310).
METAL LATH. (09220)
ALTERNATE ULTRA-LATH HEAVY DUTY
PLASTIC BY PLASTIC COMPONENT INC.
SCRATCH/BROWN PLASTER (09220)
VAPOR BARRIER (07210; 09310)
METAL STUD (09111)
EPOXY GROUT (TYP.) (09310)
TOPPING SLAB (03330)
SLOPE 1/8" / FT.
CAULK AT CORNERS (07920)
THINSET MORTAR (TYP.) (09310)
CAULK (07920)
LATH & PLASTER (09220)
STRUCTURAL SLAB PER STRUCT.
DWG'S (03330)
CERAMIC TILE (09310)
EPOXY PAINT (09912)
5/8" GLASS MAT SHEATHING BOARD
(09250) COMPLY WITH TILE COUNCIL
OF AMERICA (TCA) SYSTEM B414.
TILE CONSTRUCTION - SEE WTI-2
PER SPECS (09310) (REFER TO
DTLS THIS SHT FOR NOTES NOT
SHOWN HERE)
WALL CONSTRUCTION PER PLANS
EXPANSION JOINT SEALANT WHERE
TILE MEETS PLASTER (07920)
EPOXY PAINT PER FINISH PLAN (09912
3 COAT PORTLAND CEMENT
PLASTER APPLICATION (INCLUDING
FINISH COAT) ON CEILING - SEE
SPEC (09220)
BOND BREAKER TAPE (07920)
GLASS MAT SHEATHING BOARD (09250)
VAPOR BARRIER (07210; 09310)
CERAMIC TILE (09310)
WATERPROOF MEMBRANE (09310)
WALL CONSTRUCTION PER PLANS
WTI-2 (PER SPECS)
LAYERING IN ORDER:
PORTLAND CEMENT MORTAR
THICKSET INSTALLATION (09220)
EXPANDED METAL LATH (09220)
GLASS MAT SHEATHING BOARD (09250)
GROUT (09310)
LATEX PORTLAND CEMENT
MORTAR THINSET (09310)
0.0508M
[2"]
VERIFY DEPTH W/ MFG.
SUBFLOOR
CARPET @ FLOOR & BASE
(09680; 09681)
4" "Z" TYPE BASE (09111)
LOCKERS (10505)
D E
P R
E S
S E
D C
O N
C R
E T
E
CERAMIC TILE PER SPECS
(09310) (REFER TO DETAILS THIS
SHEET FOR NOTES NOT SHOWN
HERE)
SLOPE 1/8" / FT.
WATERPROOFING MEMBRANE -
TIE INTO DUAL INLET DRAIN AS
REQ. (09310)
EXPANSION JOINT SEALANT (07920)
GROUT (09310)
THICK SET MORTAR BED (09310)
BOND BREAKER TAPE (07920)
SUPPORT DETAIL
1'-2"1'-2"1'-2"
5 1/2" DIA. HOLE SMOOTH
POLISHED FINISH IN
COUNTERTOP
UNDER COUNTER
MOUNTED LAVATORY
SINK REFER TO PLUMBING
DRAWINGS (15410)
UNDERCOUNTER
MILLWORK, SEE
ELEVATIONS (06402).
7" SOLID SURFACE
BACKSPLASH, REFER TO
ELEVATIONS AND FINISH
SCHED. (06615)
PLAN VIEW
0.356 m 0.356 m 0.354 m
.5 m
6'-0"
1.829 m
A-5
"SLOAN" FAUCET,
REFER PLUMBING
DRAWINGS. (15410)
FAUCET AND SINK DRAIN
TO ALIGN, TYP.
ELEVATION VIEW
.7 m
.1 m
.1 m
T-4
ES-2
A-5
LP-4
A024
A024
A024
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790 Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No
Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
GDS Engineering 9201 E. 63rd Street, Suite 100 Raytown, MO 64133 Tel. 816-358-1790 Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816-931-6655 F: 816 931 9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P. 619.299.6690 F. 619.299.5513
Specifications/Labs/Security:
HDR, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
U.S. Department of Commerce, NOAA
Southwest Fisheries Science Center La Jolla, California
/1
/2
:5 :3
P
M
A024
RESTROOM DETAILS
0207-3075
October 9, 2009
NOAA La Jolla Laboratory Replacement Project
Final Construction Documents
3/4" = 1'-0"1 A160
2 SECTION @ LAVATORY R.R. COUNTER
6" = 1'-0"1 A160
3 TILE COVE BASE @ R.R. WALL, TYP.
6" = 1'-0"
4 SHEET VINYL COVED BASE
3" = 1'-0"
7 BACKSPLASH DETAIL
3" = 1'-0"
6 COUNTER SUPPORT ASSEMBLY
12" = 1'-0"
8 CERAMIC TILE AT CORNER
6" = 1'-0"1 A160
9 MARBLE THRESHOLD @ RESTROOMS
3/4" = 1'-0"1 A160
10 COUNTER TOP PLAN DETAIL
3" = 1'-0"1 A160
11 SECTION AT THRESHOLD
6" = 1'-0"
12 FLOOR TRANSITION DETAIL
1 1/2" = 1'-0"1 A160
13 SHOWER RECEPTOR DETAIL
12" = 1'-0"13 A024
14 TILE / CEILING TRANSITION @
SHOWER
12" = 1'-0"13 A024
15 TILE CONSTRUCTION @ SHOWER
1 1/2" = 1'-0"9 A160
17 CURB @ LOCKERS
12" = 1'-0"13 A024
16 TRANSITION TO FLOOR @ SHOWER
Number Revision Description Date
1 Revised 12/18/2009
1'-11"
/2
1"
3"
C L
PLAM TOE KICK (06402)
WALL TYPE PER PLAN
WATERFALL EDGE (06402)
2"DIA. HOLE FOR CORD ACCESS
DRAWER WHERE OCCURS.
PROVIDE WALL BACKING PLATE (09111)
PLAM COUNTER TOP & SPLASH (06402)
BASE CABINET (06402)
ADJUSTABLE SHELVING
(ENITRE INTERIOR SHALL BE
WHITE MELAMINE) (06402)
CEILING PER REFLECTED CEILING
PLAN (09511)
/2
1'-11"
1"
3"
WALL TYPE PER PLAN
BASE CABINET (06402)
PLAM TOE KICK (06402)
WATERFALL EDGE (06402)
CEILING PER REFLECTED CEILING
PLAN (09511)
WHERE OCCURS, ACOUSTICAL
WALL PANEL (09841)
PLAM COUNTER TOP & SPLASH (06402)
DRAWER WHERE OCCURS
PROVIDE WALL BACKING PLATE (09111)
ADJUSTABLE SHELVING
(ENITRE INTERIOR SHALL BE
WHITE MELAMINE) (06402)
1'-11" 3"
1 _ 2
WALL TYPE PER PLAN
PROVIDE SILICON BUMPERS @
DRAWERS AND CABINETS. TYP.
(06402)
CEILING PER REFLECTED CEILING
PLAN (09511)
ADJ. SHELF (TYP.) SHELF AND
INTERIOR P-LAM (06402)
P-LAM COUNTER TOP WITH
WATERFALL EDGE (06402)
PLAM TOE KICK (06402)
DRAWER WHERE OCCURS.
BASE CABINET (06402)
ADJUSTABLE SHELVING
(ENITRE INTERIOR SHALL BE
WHITE MELAMINE) (06402)
P-LAM MICROWAVE CABINETRY (06402)
12"2
/2
1'-11" 3"
1"
/2
EQ. EQ.
UPPER CABINET WHERE OCCURS (06402)
WALL TYPE PER PLAN
PROVIDE WALL BACKING PLATE (09111)
INTERIOR OF CABINET AND ADJ.
SHELVING TO BE WHITE
MELAMINE (06402)
NO DRIP EDGE (06402)
2" DIA. HOLE FOR CORD ACCESS
P-LAM COUNTER TOP & SPLASH (06402)
SINK - PER PLUMBING (15410)
P-LAM. TOE KICK (06402)
INTERIOR OF CABINET AND ADJ.
SHELVING TO BE WHITE MELAMINE
(06402)
BASE CABINET (06402)
CEILING PER REFLECTED CEILING
PLAN (09511)
E Q
S
L O
T S
1'-2" CLR.
3/4" THICK P-LAM (06402)
MAIL SLOTS 12"W X 4 1/2"H X 14"D
(CLR.) ADD IN COLUMNS, PER
ELEVATION (06402)
/4
/4
N .T
.S
N .T
.S
2'-0" 1 1/4"
1'-2"
3/4" MDO WITH P-LAM AT ALL
EXPOSED SURFACES - TYP.
COLOR TO BE SELECTED (06402)
2 LAYERS 1/2" MDO WITH P-LAM
FINISH. COLOR TO BE SELECTED
(06402)
BRUSHED ALUM. WIRE PULLS, 6"
LENGTH, TYP. (06402)
BASE PER FINISH SCHEDULE
FINISH FLOOR
EXPANSION ANCHOR AND WD.
CLEAT (06100)
WALL PER PLAN
MTL. STUD BACKER - TYP (09111)
4" HIGH CONT. BACKSPLASH W/
P-LAM FINISH. COLOR TO BE
SELECTED (06402)
3/4" MDO WITH P-LAM AT ALL
EXPOSED SURFACES - TYP.
COLOR TO BE SELECTED (06402)
DRAWER PER ELEVATION
BRUSHED ALUM. WIRE PULL-TYP.
EACH CABINET MODULE TO BE
ANCHORED TOP AND BOTTOM TO
BACKING PLATE (06402).
/4
/4
1 1/4"
VARIES -
1'-6" OR 1'-0"
SEE PLAN
1'-0"
3/4" MDO WITH P-LAM AT ALL
EXPOSED SURFACES - TYP.
COLOR TO BE SELECTED (06402)
2 LAYERS 1/2" MDO WITH P-LAM
FINISH. COLOR TO BE SELECTED
(06402)
BRUSHED ALUM. WIRE PULLS, 6"
LENGTH, TYP. (06402)
BASE PER FINISH SCHEDULE (06402)
FINISH FLOOR
EXPANSION ANCHOR AND WD.
CLEAT (06100)
WALL PER PLAN
MTL. STUD BACKER - TYP. (06402)
EACH CABINET MODULE TO BE
ANCHORED TOP AND BOTTOM TO
METAL STUD BACKER (09111)
1"
ES-1
B-2
LP-6
WALL SYSTEM PANELING
PER SPEC (06402)
BASE / CARPET
TO RUN UNDER
CABINET TO
WALL (09680;
09681)
3/4"
PROVIDE BACKING @ WALL,
TYP. (09111)
LP-6
.8 m
.3 m
/4
.0 m
0.017 m
0.025 m
.0 m
BRUSHED STAINLESS STEEL
LEDGE 1" x 2" TUBING
(05500) SECURED TO
STRUCTURE, PROVIDE
BACKING (05730)
WALL TYPE PER PLAN
TYP. ACOUSTICAL PANEL
(09841)
AP-1
/4
1"3"
LAMINATE CLAD BASE, MARINE
GRADE BACKING (06402)
FABRIC WRAPPED ACOUSTICAL
PANEL (09841)
B-3
WALL PER PLAN (09111)
(09841)AP-1
/8
/8
3/4"
1"
FABRIC WRAPPED
ACOUSTICAL PANEL
LAMINATE OVER 3/4"
BACKING (06640)
PETER PEPPER 310.639.0390 RECESSED
CONFERENCE CENTER MODEL CCR, 60"W x 48"H
4" DEEP. WHITE MARKER BOARD TACK BD.
FABRIC @ INTERIOR SIDE OF DOORS TYP. WC-2
DOOR TO BE CLAD IN WOOD VENEER TO MATCH
W-3, PLAIN SLICED CLEAR MAPLE.
BRUSHED STAINLESS STEEL
LEDGE, 1" x 2" TUBE, SECURE TO
STRUCTURE (05500).
A.F.F.
CL-1
9' - 0"
WALL PER PLAN
A025
TYP.
/2
A L
IG
N
A025
TYP.
EXTEND WALL PANEL IF
THERE IS NO STEEL
LEDGE DETAIL
/2
B-3
AP-1
/2
/2
/2
WALL TYPE PER PLAN
AP-1
ACOUSTICAL PANEL W/ 3/16"
BEVEL @ PERIMETER "Z" CLIP
TO WALL (09841)
T-3
0.559 m
1'-10"
T-3
.1 m
1'-8 1/2"
0.521 m
.5 m
/2
/2
.1 m
.0 m
MT-1
6" 1/4"
CONCRETE TOPPING
(03300)
1/4" ZINC SCREED
(03300)
CARPET TO ALIGN,
FLOAT FLOOR AS
REQUIRED (09680).
CONCRETE SLAB (03300)
CT-2
6"
0.149 m
0.006 m
/2
/2
/8
.0 m
.1 m
.0 m
1/2"
0.013 m
1/2"
0.013 m
AP-2
W-1
BASE FINISH
EXP. ENDS
1/4" CAULK JOINT
MT-1 BASE
AP-1
ACOUSTICAL FABRIC
WRAPPED w/ "Z" CLIP INSTALL
CT-2
CONCRETE
TOPPING (03300)
.1 m
/2
WALL TYPE PER PLAN
CONCRETE SLAB (03300)
1"
0.026 m
LAMINATE (06402)
LP-6
WS-1
WALL SYSTEM
MOUNTING BOTTOM
EDGE TRIM (TYP. @
TOP / SIDES).
B-3
WALL PER PLAN
INSULATION WHERE
OCCURS (07210)
AP-2
STOREFRONT DOOR HEAD (08411)
WOOD ACOUSTICAL PANEL MITER
@ DOOR FRAME & RETURN TO
WALL
WOOD BANDS FINISHED / EASED
EDGE @ END. W-1
.0 m
.0 m
/2
/4
AP-1 LP-6WS-1
FABRIC WRAPPED
ACOUSTICAL PANEL
EDGE TRIM, TYP ALL
SIDES OF WALL SYSTEM
LAMINATE WALL SYSTEM
MTL STUD (09111)
BATT INSULATION
WHERE OCCURS
(07210)
5/8" GYP. BD (09250)
ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS (08411)
AP-2
W-1
DOOR HINGE
ALIGN
MITER @ ENDS
FINISH ALL EXPOSE
EDGES
WALL PER PLAN
ADJUST DIM. AS
REQUIRED TO ALLOW
DOOR TO OPEN TO
OPEN FULLY.
ADHERED
TO DOOR
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790 Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No
Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
GDS Engineering 9201 E. 63rd Street, Suite 100 Raytown, MO 64133 Tel. 816-358-1790 Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816-931-6655 F: 816 931 9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P. 619.299.6690 F. 619.299.5513
Specifications/Labs/Security:
HDR, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
U.S. Department of Commerce, NOAA
Southwest Fisheries Science Center La Jolla, California
/1
/2
:5 :4
P
M
A025
MILLWORK DETAILS
0207-3075
October 9, 2009
NOAA La Jolla Laboratory Replacement Project
Final Construction Documents
1/2" = 1'-0"
1 TYP. BASE CABINET
1/2" = 1'-0"
2 BASE CABINET @ CONF. & COPY
1/2" = 1'-0"11 A167
3 TYP. BREAKROOM CABINET IN
ACOUSTICAL WALL
1/2" = 1'-0"2 A163
4 TYPICAL COUNTER AT SINK
1/2" = 1'-0"8 A163
5 MAILSLOT CABINETRY
1" = 1'-0"2 A163
6 TYP. UPPER & BASE CABINET
1" = 1'-0"
8 MAILROOM CABINET
1 1/2" = 1'-0"19 A166
14 CREDENZA CABINET SECTION
6" = 1'-0"18 A025
15 ACOUSTICAL PANEL / LEDGE DETAIL
6" = 1'-0"18 A025
17 LAMINATE BASE DETAIL
1 1/2" = 1'-0"2 A166
18 PRESENTATION WALL DETAIL
12" = 1'-0"9 A163
19 ACOUSTIC PANEL DETAIL
1 1/2" = 1'-0"1 A162
16 BASE CABINET @ RESTROOM
6" = 1'-0"10 A165
12 BASE / WOOD ACOUSTICAL WALL
6" = 1'-0"11 A165
11 MT-1 BASE / ACOUSTICAL PANEL
6" = 1'-0"
13 BASE / WALL PANEL
6" = 1'-0"10 A165
20 STOREFRONT DOOR / ACOUSTICAL
WOOD PANEL W
6" = 1'-0"9 A166
9 ACOUSTICAL PANEL / WALL PANEL
TRANSITION
6" = 1'-0"10 A165
7 BLIND DOOR JAMB DETAIL
Number Revision Description Date
1 Revised 12/18/2009
/8
/8
DRAWER PER ELEVATION
MTL. STUD BACKER - TYP. (09111)
BRUSHED ALUM. WIRE PULL,
6" LENGTH, TYP. (06402)
3/4" MDO WITH P-LAM AT ALL
EXPOSED SURFACES - TYP.
COLOR TO BE SELECTED
(06402)
EA. CABINET MODULE TO BE
ANCHORED TOP & BTM. TO
BACKING PLATE
WALL PER PLAN
2 LAYERS 1/2" MDO WITH P-
LAM FINISH COLOR TO BE
SELECTED (06402)
FINISH FLOOR
BASE PER FINISH SCHEDULE (06402)
3/4" MDO WITH P-LAM AT ALL
EXPOSED SURFACES - TYP.
COLOR TO BE SELECTED
(06402)
BRUSHED ALUM. WIRE PULL,
6" LENGTH, TYP. (06402)
1'-0 1/2"
/4
E
Q S
P A
C E
S
3"1'-8 1/4"
2'-3"
2'-0"
MAIL BIN
NOTE: INSTALL HARDSURFACE
FLOORING WALL TO WALL (UNDER CAB)
PRIOR TO INSTALLING CABINETRY
CEILING PER RCP
WALL TYPE PER PLAN
P-LAM INCOMING MAIL SLOTS, 1/4" TH
BLK. MELAMINE ADJUSTABLE DIVIDERS W/
3/4" TH MAIN SUPPORTS/ BOX (06402)
BRUSHED ALUM. WIRE PULL, 6" LENGTH,
TYP. (06402)
/2
/4
/4
PLASTIC LAMINATE PANEL
(06402)
LP-6
ENGINEERED STONE
COUNTERTOP (06615)
ES-1
REVEAL
PLASTIC LAMINATE FLOOR
BASE
LP-5
3 5/8" MTL. STUD PER
PARTITION TYPE (09111)
3 5/8" MTL. RUNNER (09111)
UNDER COUNTER
SUPPORT (06402;
05500)
1'-0"
.8 m
.2 m
.2 m
.4 m
.0 m
.2 m
.0 m
.0 m
/2
.0 m
0.304 m
1 1/2"
0.038 m
0.609 m
0.077 m
/8
PLASTIC LAMINATE BASE CABINET (06402)
WATERFALL EDGE
E Q
/8
E
Q
/8
E
Q
.0 m
E Q
.0 m
/8
.0 m
CL-3 @ CEILING & WALL.
SECURE ACOUSTICAL
FABRIC TO CLG
APPLICATION ONLY (09511).
AP-2
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790 Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No
Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
GDS Engineering 9201 E. 63rd Street, Suite 100 Raytown, MO 64133 Tel. 816-358-1790 Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816-931-6655 F: 816 931 9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P. 619.299.6690 F. 619.299.5513
Specifications/Labs/Security:
HDR, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
U.S. Department of Commerce, NOAA
Southwest Fisheries Science Center La Jolla, California
/1
/2
:0 :1
P
M
A026
MILLWORK DETAILS
0207-3075
October 9, 2009
NOAA La Jolla Laboratory Replacement Project
Final Construction Documents
1" = 1'-0"2 A163
2 CABINET DETAIL WITH DRAWERS
3/4" = 1'-0"1 A164
3 MAIL CABINET
1 1/2" = 1'-0"1 A164
4 WORKSTATION SECTION
1" = 1'-0"
5 BASE CABINET DETAIL
1 1/2" = 1'-0"10 A165
6 ACOUSTICAL PANEL SYSTEM
PARTIAL ELEVATION DETAIL
1 1/2" = 1'-0"
8 LOBBY DISPLAY CAB. SECTION
3" = 1'-0"
10 LOBBY PANELING BASE
6" = 1'-0"
11 GARAGE ENTRY WALL / BASE
1 1/2" = 1'-0"
9 LOBBY DISPLAY CAB. SECTION
6" = 1'-0"
12 GARAGE ENTRY MT-1 WALL / BASE
6" = 1'-0"
13 LOBBY PANELING / BLIND DOOR
Number Revision Description Date
1 Revised 12/18/2009
FD FD
208-230V
208-230V
208V-15A20 8-
0V
UP
UP
DN
UP
UP
UPDN
UP
UP
1. CONTRACTOR TO FIELD VERIFY ALL
MEASUREMENTS AND CONDITIONS NEW AND
EXISTING. NOTIFY THE ARCHITECT/OWNER'S
REPRESENTATIVE OF ANY DISCREPANCIES.
2. ENLARGED PLANS MAY BE ROTATED OR
MIRRORED COORDINATE WITH MAIN FLOOR PLAN.
3. ALL DIMENSIONS ARE TO THE FACE OF STUD
OR COLUMN CENTERLINES, UNLESS OTHERWISE
NOTED.
4. CONTRACTOR TO PROVIDE 4'-0" HIGH
PLYWOOD BACKER BOARD IN ALL MECHANICAL AND
ELECTRICAL ROOMS MOUNTED 3'-6" A.F.F. FOR
PERIMETER OF ROOM
5. PROVIDE MOLD RESISTANT GYPSUM BOARD AT
ALL EXTERIOR WALLS.
6. PROVIDE METAL TRIM OR CASING AT ALL
EDGES OF PLASTER AND DRYWALL SURFACES
WHERE IT TERMINATES OR MEETS ANY OTHER
MATERIAL, UNLESS NOTED OTHERWISE
7. PROVIDE METAL CORNER BEADS AT ALL
OUTSIDE CORNERS OF PLASTER AND DRYWALL
SURFACES, UNLESS NOTED OTHERWISE.
8. CONTRACTOR TO PROVIDE WOOD BLOCKING
BEHIND ALL TOILET ROOM ACCESSORIES, GRAB BARS,
HANDRAILS, WOOD TRIM, AND WALL MOUNTED
FIXTURES.
GENERAL NOTES:
A201
A201
A200
G1
G1
A7
9.1
A B C D E G H
Y6
Y4
Y3
Y2
Y1
W2 W5
J
DIVISION DIR.
308 ADMIN. ASST.
RESEARCH BIOLOGIST
SCIENTIST CONTRACTOR
OCEANOGRAPHY
ECOLOGIST
I.T. SPECIALIST
RESEARCH FISH BIO.
RESEARCH FISH BIO. GEN.
RESEARCH FISH BIO. GEN.
SHARED OFFICE
SHARED OFFICE
RESEARCH FISH BIO.
SHARED OFFICE COMP.
SPEC.
ECOLOGIST TURTLES
OPER. RESEARCH
ANALYST ETP
OPER. RESEARCH
ANALYST
SHARED OFFICE
RESEARCH FISH BIO/EEZ
337SCIENTIST II ANTARTIC
RESEARCH FISH BIO.
335OPER. RESEARCH
ANALYST
RESEARCH NUC. GEN./
ANALYSIS
DIVISION DIRECTOR
BIOLOGIST
RESEARCH NUC.
GEN./ANALYSIS
MEN'S RR.
301B
WOMEN'S RR.
301A
I.D.C.
301D
ELEC.
301C
SUPVR. ZOOLOGIST
TURTLES
SUPVR. RESEARCH FISH
BIO/GEN
SUPVR. OPER. RESEARCH
/ EEZ
SUPVR. ECOL.
SUPVR. RES. FISH BIO.
TEAM CONF. ROOM
TEAM CONF. ROOM
MULTIPURPOSE ROOM
SUPVR. ECONOMIST
OPTICAL COMPARITOR
SUPVR. MOLECULAR GEN.
SUPVR. I.T. SPECIALIST
SHARED OFFICE
SHARED OFFICE
ECONOMIST
RESEARCH FISH
BIOLOGIST
SENIOR BIOLOGIST
SENIOR BIOLOGIST
RESEARCH FISH
BIOLOGIST
RESEARCH FISH
BIOLOGIST
ANALYST
RESEARCH WILDLIFE BIO.
ASSISTANT
ASSISTANT SCIENTIST
ELEC.
355C
INTERPRET. LAB OFFICE
RESEARCH OCEANOGR.
RESEARCH FISH BIO.
SUPVR. OCEAN ACOUSTIC
ENG.
SUPVR. RESEARCH FISH
BIO.
SUPVR. RESEARCH FISH
BIO.
TEAM CONFERENCE
DIVISION DIRECTOR
BIOLOGIST
COMPUTER COAST
WATCH
SCIENTIST II CONTRACT
I.T. SPEC.
JANITOR
355E
WORKROOM
I.D.C.
355D
SUPVR. I.T. SPEC.
MEN'S RR.
355B
WOMEN'S RR.
355A
STORAGE
300A
JAN.
301E
STORAGE
300B
SHARED OFFICE
SCIENTIST
SHARED OFFICE
SCIENTIST
CORRIDOR
383A
ROV VIDEO/OTOLITH LAB
EEZ MAMMALS LAB
TAXONOMY LAB
POST PCR LAB
PRE PCR LAB
GENERAL LAB
MARINE MAMMAL
STRANDING LAB
POST PCR
INSTRUMENTATION LAB
OCEANOGRAPHIC &
ACOUSTIC LAB
AERD STAGING DRY LAB
ANCIENT DNA
PHOTOGRAMMETRY SUITE
PRD ACOUSTICS LAB
I.D.C.
388A
ELEC
388B
ECOSYSTEM/
OCEANOGRAPHIC LAB
CHEMISTRY LAB
CLEANROOM CLASS
100,000
399B
CLEANROOM CLASS
10,000
399C
AERD DRY LAB & CCAMLR
ARCHIVE
FILM ARCHIVE
CLEANROOM CLASS 100
399D
FREEZER STORAGE
SHARED OFFICE BIOTECH
III
SHARED OFFICE
SHARED OFFICE
SHARED OFFICE
SHARED OFFICE
SHARED OFFICE
SHARED OFFICE
SHARED OFFICE
SHARED OFFICE
SHARED OFFICE
SHARED OFFICE
319SHARED OFFICE
BIOTECH II
OPEN OFFICE
OPEN OFFICE
OPEN OFFICE
383B
OPEN OFFICE
383C
A202 D11
T1
A202 H1
V2 V4
Y4.5
A200 A1
A201
G10
A201
A1
A202 M1
A201
M10
A202
M8
A201 M16
A201
M5
A201
M1 A201
A201
Q1
Q7 A201
Q15
A202
A13
A202
Q1
A202D1
A202
Q6
A202Q11
Q16
A200 N1
A9
A313
W8
A1
A317
A13
A316
A10
A315
A13
A314 A13
A319
A9
A319
A13
A318
A9
A318
A13
A321
A9
A321
A10
A322
A9
A323
A13
A331 A13
A337
A13
A329
A9
A328
A13
A335
A7
A330
A5
A334
A13
A333
Q11
A13
A332
A10
A336
A13
A327
A10
A325
A9
A312
V1
N18
A352
J18
A352
E10
A352
A13
A352
E18
A352
E14
A352 J9
A352
N14
A352
A18
A352
N6
A352
FE.1 F.5
X1
Y5
A412 J16
A401 K16
X6
100°
10' - 0" 4' - 0"
4'
0"
8'
0"
J1
A300
A1
A300
A1
A301 J1
A301
A1
A302
J1
A302
A1
A303
J1
A303
A414 L4
A414
L10
A414
L16
A542
K19
A541
F4
A202 H1
A202
M8
A14
A352
N13
A352
A326 L6
A400 J17
A210L15
15' - 0" 30' - 0" 36' - 0" 36' - 0" 9' - 6" 26' - 6" 15' - 0" 15' - 0" 30' - 0" 67' - 0 1/2"
31' - 3 1/16"
1' - 6" 19' - 7"
0.458 m
5.969 m
9.527 m
1.
m
3.
m
2.
m
3.
m
9.
m
6.
m
3.
m
4.
m
9.
m
9.
m
9.
m
9.
m
9.
m
9.
m
9.
m
4.572 m 9.144 m 10.973 m 10.973 m 2.896 m 8.077 m 4.572 m 4.572 m 9.143 m 20.434 m
4.
m
4.
m
4.
m
8.
m
8.
m
8.
m
/4
/8
1/
/8
/8
/8
1.219 m 3.048 m
A1
A328
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790 Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
Gibbens Drake Scott, Inc.
9201 E. 63rd Street, Suite 100 Raytown, MO 64133 P: 816.358.1790 F: 816.358.2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816.931.6655 F: 816.931.9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P: 619.299.6690 F: 619.299.5513
Specifications/Labs/Security:
HDR Architecture, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems Corporation 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
Life Support System Consultant:
MWH Americas, Inc.
9444 Farnham Street, Suite 300 San Diego, CA 92123 P: 858.751.1200 F: 858.751.1201
U.S. Department of Commerce, NOAA
10/9/2009
8901 La Jolla Shores Drive La Jolla, California 92037
/1
8/
:5 6:
P
M
A130
LEVEL 3 - OVERALL
FLOOR PLAN…