GENERAL NOTE
STEEL STUD ALLOWABLE HEIGHTS ARE BASED ON 5 PSF AND L/240 DEFLECTION DATA PUBLISHED
BY THE STEEL STUD MANUFACTURERS ASSOCIATION (SSMA), THE METAL STUD MANUFACTURERS
ASSOCIATION (MSMA), NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS
(NAAMM). HEIGHTS SHOWN CAN BE INCREASED BY CHANGING STUD GAUGE AND SPACING AS
NOTED IN THESE STANDARD DATA SOURCES.
ALL EXTERIOR WALLS SHALL HAVE INSULATION WITH A R- (FILL IN #) VALUE. FOR MORE DETAILED
INFORMATION, SEE WALL TYPES AND SPECIFICATIONS.
ALL ROOF AREAS SHALL HAVE A COMBINED TOTAL R- (FILL IN #) VALUE. FOR MORE DETAILED
INFORMATION SEE REFLECTED CEILING PLANS, ROOF PLANS, AND SPECIFICATIONS.
SEE SHEETS A041, A042 FOR FULL HEIGHT WALL TYPICAL DETAILS.
SEE SHEETS A041, A042 FOR TYPICAL DETAILS.
SEE SHEETS A041, A042 FOR TYPICAL CONTROL JOINT DETAILS.
/2 M
IN
PROVIDE 1/2"
UNDERCUT @
MTL STUDS
ANCHOR GYP BD
TO STUDS NO
CLOSER THAN
6" TO TRACK
TOP EDGE OF
GYP BD
DEEP LEG TRACK
ATTACH TO UNDERSIDE
OF DECK/STRUCTURE
DO NOT ANCHOR STUDS
TO TRACK
CONT. BRIDGING
/2 M
IN
MTL STUDS
GYP BD EA SIDE
PROVIDE 1/2"
UNDERCUT @
MTL STUDS
ANCHOR GYP BD
TO STUDS NO
CLOSER THAN
6" TO TRACK
TOP EDGE OF
GYP BD
DEEP LEG TRACK
ATTACH TO UNDERSIDE
OF DECK/STRUCTURE
DO NOT ANCHOR STUDS
TO TRACK
CONT. BRIDGING
/2 M
IN
MTL STUDS
GYP BD EA SIDE
PACK DECK FLUTES
TIGHT W/ FIRE SAFING
FIRE SEALANT
WALL
FIRE STOPPING @
TOP OF FURRED SPACE
FURRED SPACE SEE
PLAN FOR SIZE
SEAL ALL PENETRATIONS @ FIRE
STOPPING W/ FIRE SAFING (TYP.)
CEILING
NOTE: FOR COMBUSTIBLE FURRING
LOCATIONS PROVIDE FIRE
STOPPING AT CEILING LINE
M
IN
.0
.0
°MTL STUD BRACES TO
STRUCT. ABOVE @ 48" O.C.,
ALTERNATE DIRECTION
CEILING
SEAL ALL PENETRATIONS
IN TOP OF TRACK W/ FIRE
SEALANT.
.0
.0
°MTL STUD BRACES TO
STRUCT. ABOVE @ 48" O.C.,
ALTERNATE DIRECTION
CEILING
SEAL ALL PENETRATIONS
IN TOP OF TRACK W/ FIRE
SEALANT.
CEILING OF VARYING HEIGHT
((NON-COMBUSTIBLE WALL))
PACK STUD CAVITY W/ FIRE
SAFING @ LOWER CEILING
LINE. ALT: RUN GYP BD TO TOP
TRACK IN LIEU OF FIRE SAFING
M
IN
M
IN
BASIC PARTITION THICKNESS
NOTES:
1) REFER TO STRUCTURAL FOR ADDITIONAL INFORMATION
ON SHEET S400
M
M1
7 5/8"
CMU"
7 5/8"
YES
FIRE RATING (HRS)
FIRE TEST NUMBER
ACOUSTICAL RATING (STC)
ACOUSTICAL TEST NUMBER
ACOUSTICAL JOINTS
FIRE RESISTIVE JOINTS
MASONRY SIZE (VERTICAL)
MASONRY MATERIAL
PARTITION SYSTEM:
MASONRY PARTITION
TO STRUCTURE ABOVE
TO 6" ABOVE CEILING
PARTITION IDENTIFICATION PLAN
SYMBOL
REMARKS
SEISMIC ANGLES PER STRUCTURAL
FIRE SAFING AND SEALANT
BOND BEAM STARTER COURSE
DOWELED TO SLAB
RE: STRUCTURAL
PARTITION IDENTIFICATION PLAN
SYMBOL
REMARKS
BASIC PARTITION THICKNESS
G
FIRE RATING (HRS)
FIRE TEST NUMBER
ACOUSTICAL RATING (STC)
ACOUSTICAL TEST NUMBER
INSULATION THICKNESS
GWB THICKNESS
ACOUSTICAL JOINTS
FIRE RESISTIVE JOINTS
STUD SIZE
STUD SPACING (O.C.)*
PARTITION SYSTEM:
GYPSUM WALL BOARD PARTITION
BASIC PARTITION THICKNESS
NOTES:
1) CONFIRM STUD SPACING WITH STRUCT.
F
F2
4 1/4"
24"
3 5/8" MS
5/8" X
-INSULATION THICKNESS
GWB THICKNESS
STUD SIZE
STUD SPACING (O.C.)
PARTITION SYSTEM:
GYPSUM FURRING PARTITION
PARTITION IDENTIFICATION PLAN
SYMBOL
REMARKS
NOTES:
1) CONFIRM STUD SPACING WITH STRUCT.
2) PROVIDE MOISTURE RESISTANT GWB IN WET AREAS.
3) EXTEND ALL FIRE RATED WALLS STRUCTURE TO STRUCTURE.
4) USE TYPE "X" GWB FOR ALL FIRE RATED PARTITIONS
5) ALL WALLS SHALL BE FULL HEIGHT U.N.O. (STUDS TO BOTT. OF
STRCT.)
G1
4 7/8"
24"
3 5/8" MS
5/8" X
NO
G1a
4 7/8"
24"
3 5/8" MS
5/8" X
2 1/2"
NGC 2386
NO
BEARING WALL NO NO
RESILIENT CHANNELS
- YES
BASIC PARTITION THICKNESS
NOTES:
1) PROVIDE MOLD RESISTANT GWB IN WET AREAS.
2) EXTEND ALL FIRE RATED WALLS STRUCTURE TO STRUCTURE.
3) USE TYPE "X" GWB FOR ALL FIRE RATED PARTITIONS
S
S1
5 1/4"
24"
4" CH
(2) 5/8"X
UL-U438
YES
FIRE RATING (HRS)
FIRE TEST NUMBER
INSULATION THICKNESS
GWB THICKNESS
FIRE RESISTIVE JOINTS
STUD SIZE
STUD SPACING (O.C.)*
PARTITION SYSTEM:
GYPSUM SEPARATION PARTITION
PARTITION IDENTIFICATION PLAN
SYMBOL
REMARKS
1" XSHAFT WALL LINER THICKNESS
N/A
F3
6 5/8"
24"
6" MS
5/8" X
G3
7 1/4"
24"
6" MS
5/8" X
U419
YES
NO
G4
6 1/8"
24"
3 5/8" MS
(2) 5/8" X
EA. SIDE
NO
NO
G5
8 1/2"
24"
6" MS
U419
YES
NO
M2
7 5/8"
CMU"
7 5/8"
2 HR
UL-U905
YES
YES
G2
4 7/8"
24"
3 5/8" MS
5/8" X
U419
YES
NO
F1
2 1/4"
24"
1 5/8" MS
5/8" X
YES
GWB TO STRUCTURE
STUDS TO STRUCTURE ABOVE
YES
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
STUDS TO 6" ABOVE CEILING NO NO NO NO NONONO
NO
NO
GWB TO STRUCTURE
STUDS TO STRUCTURE ABOVE
NO
STUDS TO 6" ABOVE CEILING NOYES
5/8" GYPSUM WALLBOARD
(09250)
METAL RUNNER (09111)
JOINT SEALANT (07920)
METAL RUNNER (09111)
JOINT SEALANT (07920)
5/8" GYPSUM WALLBOARD
(09250)
METAL EXPANSION RUNNER
(09111)
JOINT SEALANT (07920)
METAL RUNNER (09111)
JOINT SEALANT (07920)
GYPSUM SHAFT LINER (09265)
5/8" GYPSUM WALLBOARD
(09250)
METAL EXPANSION RUNNER
(09111)
JOINT SEALANT (07920)
METAL RUNNER (09111)
JOINT SEALANT (07920)
G6
7 1/4"
24"
6" MS
5/8" X
NO
NO
YES
YES
NO
BATT INSULATION WHERE
INDICATED PER WALLTYPE
(07120)
G7
7 1/4"
24"
6" MS
U419
YES
NO
YES
YES
NO
M3
7 5/8"
CMU"
2 HR
UL-U905
YES
YES
M4
7 5/8"
CMU"
2 HR
UL-U905
YES
YES
7 5/8" 7 5/8"
G1b
4 7/8"
24"
3 5/8" MS
5/8" X
NO
NO
YES
NO
G1c
24"
5/8" X
NO
NO
YES
NO
7 1/4"
6" MS
NO NO
NO NO
G5a
6 1/8"
24"
3 5/8" MS
U419
YES
NO
YES
YES
NO
F1a
2 7/8"
24"
1 5/8" MS
(2) 5/8" X
1 SIDE
NO
NO
NO
YES
F2a
2 7/8"
24"
(2) 5/8" X
1 SIDE
NO
NO
NO
YES
3 5/8" MS
(2) 5/8" X
EA. SIDE
(2) 5/8" X
EA. SIDE
(2) 5/8" X
EA. SIDE
G4a
6 1/8"
24"
3 5/8" MS
(2) 5/8" X
1 SIDE
NO
NO
YES
YES
NO
M
7 5/8"
CMU"
7 5/8"
NA
YES
1 HR
UL-U905
YES
50ACOUSTICAL RATING (STC)
RATED WALL ASSEMBLY
(1 HR SHOWN)
NON RATED WALL
ASSEMBLY
CONTINUE GYP. BD BEHIND
STUD - PROVIDE PROPER
PENETRATION PROTECTION
AT PENETRATIONS OF WIRE,
CONDUIT, ETC. AT THIS AREA.
NON RATED WALL
ASSEMBLY
RATED WALL ASSEMBLY
(2 HR SHOWN)
CONTINUE GYP. BD BEHIND
STUD - PROVIDE PROPER
PENETRATION PROTECTION
AT PENETRATIONS OF WIRE,
CONDUIT, ETC. AT THIS AREA.
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790
Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No
Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
GDS Engineering 9201 E. 63rd Street, Suite 100 Raytown, MO 64133 Tel. 816-358-1790 Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816-931-6655 F: 816 931 9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P. 619.299.6690 F. 619.299.5513
Specifications/Labs/Security:
HDR, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
U.S. Department of Commerce, NOAA
Southwest Fisheries Science Center La Jolla, California
/1 /2 :0 :3 P M
A040
INTERIOR WALL TYPES
0207-3075
October 9, 2009
NOAA La Jolla Laboratory Replacement Project
Final Construction Documents 1 1/2" = 1'-0"
A1 NON RATED PARTITION TO UNDERSIDE OF DECK
1 1/2" = 1'-0"
D1 RATED PARTITION TO UNDERSIDE OF DECK
1 1/2" = 1'-0"
G1 TOP OF FURRING WALL
1 1/2" = 1'-0"
L1 NON-RATED PARTITION 6" ABOVE CEILING
1 1/2" = 1'-0"
A7 PARTITION TYPES
1 1/2" = 1'-0"
G4 WALL INTERSECTIONS
Number Revision Description Date
1 Amendment 2 12/09/2009
E
LEVEL 1
221' - 0"
LEVEL 2
236' - 0"
DOCK ENTRANCE
218' - 0"
ANTEROOM
THAWING
2.18
NECROPSY
2.16
NECROPSY
FREEZER
2.16A
AUV/ROV
2.33
2000 LB CAPACITY STAINLESS STEEL RAIL
SYSTEM INTO THROUGH-PUT FREEZER (ROOM
121). PIVOTING LINK BEAM TO PROVIDE
CONTINUOUS CONNECTION BETWEEN
EXTERIOR AND INTERIOR MONORAILS AT
DOOR OPENING
MIN
2' - 6"
1'
N1
QA301
" T
YP
H1
QA301
4"
2000 LB CAPACITY STAINLESS STEEL RAIL
SYSTEM INTO NECROPSY (ROOM 117).
PIVOTING LINK BEAM TO PROVIDE
CONTINUOUS CONNECTION BETWEEN
EXTERIOR AND INTERIOR MONORAILS AT
DOOR OPENING
15,000 LB CAPACITY STAINLESS
STEEL RAIL SYSTEM INTO NECROPSY
FREEZER (ROOM 119). PIVOTING LINK
BEAM TO PROVIDE CONTINUOUS
CONNECTION BETWEEN EXTERIOR
AND INTERIOR MONORAILS AT DOOR
OPENING
2000 LB CAPACITY STAINLESS STEEL RAIL SYSTEM
INTO AUV/ROV AND AST ELECTRONICS LAB.
PIVOTING LINK BEAM TO PROVIDE CONTINUOUS
CONNECTION BETWEEN EXTERIOR AND INTERIOR
MONORAILS AT DOOR OPENING
1'
6" 2"
2"
1'
1"
0"
LEVEL 1
221' - 0"
LEVEL 2
236' - 0"
DOCK ENTRANCE
218' - 0"
ENTRY
216' - 6"
Level 1 - EL=221' 221' - 0"
Level 2 - EL=236' 236' - 0"
N9
QA301
NECROPSY
FREEZER
2.16A
PIVOTING RAIL SEGMENT
CONNECTING INTERIOR AND
EXTERIOR RAILS, TYP
1" 1'
8"
1"
STAINLESS STEEL
MOBILE/MANUAL
CHAIN HOIST
STAINLESS STEEL RAIL, TYP
STAINLESS STEEL HOOK
CARRIER, TYP INSIDE
FREEZER
8"
9'
0" 10
0"
"1
0"
ESTIMATED S
BEAM SIZE FOR
2K CAPACITY
ESTIMATED S BEAM
SIZE FOR 15K
CAPACITY
8'
2"9'
4"
FIXED SS
ELECTRIC WIRE
HOIST
LEVEL 1
221' - 0"
LEVEL 2
236' - 0"
DOCK ENTRANCE
218' - 0"
ENTRY
216' - 6"
Level 1 - EL=221' 221' - 0"
Level 2 - EL=236' 236' - 0"
LEVEL DOCK
218' - 0"
N9
QA301
AUV/ROV
2.33
AST
ELECTRONICS
LAB
4.80
PIVOTING RAIL SEGMENT
CONNECTING INTERIOR AND
EXTERIOR RAILS, TYP
STAINLESS STEEL RAIL, TYP
STAINLESS STEEL HOOK CARRIER, TYP
STAINLESS
STEEL
MOBILE/MANUAL
CHAIN HOIST
LEVEL 1
221' - 0"
LEVEL 2
236' - 0"
E F
LEVEL ENTRANCE
218' - 0"
N1
QA301
H1
QA301
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790 Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
GDS Engineering 9201 E. 63rd Street, Suite 100 Raytown, MO 64133 Tel. 816-358-1790 Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816-931-6655 F: 816 931 9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P. 619.299.6690 F. 619.299.5513
Specifications/Labs/Security:
HDR, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
U.S. Department of Commerce, NOAA
10/09/2009
8901 La Jolla Shores Drive La Jolla, California 92037
/1
1/
:4 5:
A
M
QA301
PARTIAL SECTIONS AND
ELEVATIONS - LAB
EQUIPMENT
436784-73621 October 9, 2009
NOAA La Jolla Laboratory Replacement Project
Final Construction Documents
1/4" = 1'-0"H1 QA301
N9 PARTIAL SECTION - HOISTS AT LEVEL 1 DOCK
1/4" = 1'-0"H9 QA301
N1 CROSS SECTION AT NECROPSY FREEZER DOCK ENTRANCE
1/4" = 1'-0"H9 QA301
H1 CROSS SECTION AT AUV/ROV DOCK ENTRANCE
1/4" = 1'-0"A1 QA402
H9 PARTIAL ELEVATION AT LOADING DOCK
Number Revision Description Date 1 Amendment 2 12/09/2009
DN
C D E
F F.5
X6
B.9
QA201N1
QA201 N8
4°C ±0.5°C
-20°C ± 0.5°C
-20°C ±0.5°C
S +36"
E +30"
S +36"
W G
A W
G
A
B L3
6A
BL
C
BL
C
BL
KO
BL36A BLKO30
B3 6A
B3 6A
SK36A B24C B24C
KO
1' - 4"
4°C - 20°C ±0.5°C
S +36"
(2) 6'-0"W x 3'-0"D
'METRO WIRE'
STORAGE RACKS
AUV/ROV
EQUIPMENT
AUV/ROV
EQUIPMENTAUV/ROV
EQUIPMENT
FLOOR TO CEILING
84" x 60"
WORK TABLE
W/ CASTERS
72" x 60"
WORK TABLE
W/ CASTERS
HYPERBARIC
TANK 6' X 6'
* VERY NOISY TEST TANK
6' X 6'
TEST
TANK
2' X 3'
HYPERBARIC
PERIPHERAL
EQUIPMENT
E +36"
E +36"
E +36"
TRENCH DRAIN
SNORKEL
EXHAUST
255 CMH
150 CFM
(TYP. 4)
*PHENOLIC
RESIN
CASEWORK
B3 6B
B3 0A
B1 8B
B1 8B
B2 4B
B3 6B
KO
E +36"
2000 LB
CAPACITY
HOIST
MAXIMUM
T3622A T3622A
OP
EN
B
EL
OW
U G
W
E +36"
B3 0A
B2 4B
POSITIVE PRESSURE
E +36"
B24B B1 8C
B2 4A
UCR
(3) 24"D, 84" TALL
(5) SHELF, METAL
SHELVING UNITS
-20°C ±0.5°C
1-1/4 HP
GARBAGE
DISPOSAL
EQ.
NECROPSY
DOWNDRAFT
TABLE WITH
HYDRAULIC
LIFT (TYP. 3)
OP
EN
B
EL
OW
RAMP
S +36"
S +36"
S +36"
S +36"
MT
A
MT
A
W
A2
W
A2
CF
H9
6V a
U C
R
NECROPSY
STORAGE
117A
SLOT HOOD BY
DIV 15
2' - 6" MIN
S +36"
W
A2
W
A2
12" TRENCH DRAIN, TYP.
OVERHEAD SERVICE
CARRIER, TYP.
DARKENING
CURTAINS, TYP (OFOI)
3' x 8'
TANK, TYP.
TRENCH
DRAIN
TRENCH
DRAIN MICROSCOPE
STAINLESS
STEEL
12" DEEP SS
FLR TO CLNG
OPEN SHELVING BELOW
48" x 18" x 84" SS
SHELVING UNITS
GROWTH LIGHTS IN
VERTICAL PATTERN
OVERHEAD TRACK SYSTEM, TYP
OVERHEAD
SERVICE CARRIER
RACEWAY TANKS,
TYP (OFOI)
TANKS, TYP
(OFOI)
B1 8A
KO
STRAHMAN PRESSURE
WASH STATION W/ LONG
HOSE - CONNECTION TO
SANITIZER SYSTEM
ALL TALL STORAGE CABINETS IN THIS
ROOM TO HAVE LOCKS
QA201 G1
TF4318B
T3
2A
SK30A B24A B24C
BSL-2 LAB
E +36"
E +36"
B24A B18C
T3
2A
KO
B1 8B
F3 0A
S K3
0A
KO
B1
8B
T4822A T3622A B3 6A
SK
A
SK
A
B3 6C
B2 4C
B1 8A
T3
2A T3
2A
KO
REF
OFOI
CDA-5
TF4318B
MB24B
AUV/ROV
EQUIPMENT
AUV
(INCLUDING
CART)
MB
B
MB
B
SNORKEL
EXHAUST
255 CMH
150 CFM
E +36"
MB
B
E +36"
SNORKEL EXHAUST
255 CMH 150 CFM
SPECIMEN
PREP/PROCEDURE
2.17
ABALONE BROOD
STOCK HOLDING
ROOM*
105C
2.30
ABALONE BROOD
STOCK HOLDING
ROOM*
105D
2.28
ABALONE WET
LAB*
105B 2.27
ABALONE DRY
LAB*
105A 2.29
CORRIDOR
AQUARIUM
CUTTING ROOM
104A 2.26
AQUARIUM
FREEZER
104B 2.31
COLD/CONST.
TEMP. ROOM
104D 2.22
AQ OFC
104C
AQUARIA
2.25
THROUGH-PUT
FREEZER
2.18
ANTEROOM
THAWING
2.18
NECROPSY
2.16
NECROPSY
FREEZER
2.16A
AUV/ROV
2.33
AST
ELECTRONICS
LAB
4.80
AST ACOUSTIC
WET LAB
4.81
X-RAY
107D
2.15
TRENCH
DRAIN
OVERHEAD
SERVICE
CARRIER
3/4 HP DISPOSAL
MT
A
MT
A
MT
A
MT
A
MB
B
MB
D
MB24BMB24B
MT84A MT84A
TF
B
CF
H9
6V a
HCW-h
HCW-h
SK-10
SK-10
SK-10
SK-10
HCW-h
HCW-h
E +36"
MT
A
E +36"
S K3
6A S
K3 6A
4"
1' - 0"
4"
2' - 0"
CURB WITH
TRENCH DRAIN
CURB WITH
TRENCH DRAIN
3'
8"3' - 8"
(1) 48"W
UNIT
(3) 36"W
UNITS
(10) 24"W
UNITS
CDA-5
C D
A-
C D
A-
H C
W -P
R -2
C W
-3
C W
-3
EW
ES
-1
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
CDA-4
HCW-2
HCW-2
EWES-1
EWES-1
CDA-5
CDA-5
C D
A-
C D
A-
C D
A-
CDA-5
C D
A-
C D
A-
CDA-5
C
D A-
2" x 2" x 36"
BAR BEAM
SUPPORT
E-3
E-1
C W
-3
E-6
CDA-1
CDA-1
CART
SPACE
U
LF
BSC60
E-9
3,004 mm 9' - 10 1/4"
5'
7/
8"
1, m m 5, m m
3,297 mm 3, m m
1, m m
4'
/1
6" 7'
0"
FD
N9
QA301
N1
QA301
EW-1
H1
QA301
EW-1
3a 18" FLOOR
TO CEILING
M B1
5C
SHOWER - REFER TO
PLUMBING PLANS
A-SEA
(2) HOSE REELS - 1 FOR
SEAWATER/1 FOR
FRESHWATER
TYP
R 2' - 6"
R 2' - 6"
R 2' - 6"
EQ EQ
EQ EQ
2' - 4"
1' - 1"
E-4
E-4
E-4
SK-12
HCW-3
TRENCH
DRAIN
BL24A
T3622A
3,297 mm 10' - 9 13/16"
5'
0" 3, m m
1, m m
E-2 1, m m1,118 mm
TANKS, TYP
(OFOI)
TANKS, TYP
(OFOI)
2, m m
3' x 8'
TANK, TYP.
TANK,
OFOI
MT48A
(5) TIER SS WIRE
SHELVING UNITS,
48" x 24" x 84"
(5) TIER SS WIRE SHELVING
UNITS, 48" x 24" x 84" (TYP OF 4)
QA301
H9
ZONE
DESIGNATES AN
AGGREGATE
RAIL CAPACITY
OF 15,000 LBS
2,000 LB
CAPACITY
MANUAL
HOIST, THIS
RAIL
TY
PR 2'
- 6
7'
4"
FIXED SS
ELECTRIC
HOIST
2,000 LB
CAPACITY
MANUAL
HOIST, THIS
RAIL
2000 LB RAIL
CAPACITY, TYP
2000 LB RAIL
CAPACITY
15000 LB RAIL
CAPACITY INSIDE
FREEZER
LABORATORY CHAIRS/STOOLS ARE SHOWN FOR CLARIFICATION
AND ARE NOT PART OF THIS CONTRACT.
SEE QA001 FOR LAB EQUIPMENT SCHEDULES.
SEE QA002 FOR LAB ABBREVIATIONS AND SYMBOLS, CASEWORK,
SERVICE AND FUMEHOOD TYPES.
SEE QA501 FOR FIXED CASEWORK DETAILS.
SEE QA502 FOR MOBILE CASEWORK AND TABLE DETAILS.
SEE QA503 FOR ACCESSORY AND CONTROLLED ENVIRONMENT
DETAILS.
SEE QA504 FOR UMBILICAL AND SHELVING DETAILS.
SEE QA505 FOR MOBILE BENCH DETAILS.
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
SHEET NOTES
ACCESSORY LEGEND
DRYING RACK - SEE QA002 AND G6/QA503.
UMBILICAL - SEE QA002 AND QA504.
ADJUSTABLE SHELVES - NORMAL DUTY (3 TIER WOOD,
UON) - SEE QA002, QA503 AND QA504.
ADJUSTABLE SHELVES - HEAVY DUTY (3 TIER WOOD,
UON) - SEE QA002, QA503 AND QA504.
CYLINDER RESTRAINTS - SEE QA002 AND A17/QA503.
WATER POLISHER SUPPORT - SEE QA002 AND
ELECTRICAL/PLUMBING DRAWINGS.
3a
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790 Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No Date:
Sheet:
UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE
IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT
INTENDED FOR CONSTRUCTION, RECORDING PURPOSES OR
IMPLEMENTATION
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Q
R
S
18 19 20
21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2118 19 20
Prime Consultant - MEP FP Engineer:
GDS Engineering 9201 E. 63rd Street, Suite 100 Raytown, MO 64133 Tel. 816-358-1790 Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC 4041 Mill Street Kansas City, Missouri 64111 P: 816-931-6655 F: 816 931 9640
Associate Architect:
Architects | Delawie Wilkes Rodrigues Barker 2265 India Street San Diego, CA 92101 P. 619.299.6690 F. 619.299.5513
Specifications/Labs/Security:
HDR, Inc.
8690 Balboa Avenue, Suite 200 San Diego, CA 92123 P: 858.712.8347 F: 858.712.8333
Structural Engineer:
TranSystems 2400 Pershing Road, Suite 400 Kansas City, MO 64108 P: 816.329.8600 F: 816.329.8602
Civil Engineer:
RBF Consulting Engineers 9755 Clairemont Mesa Blvd. #100 San Diego, CA 92124 P: 858.614.5000 F: 858.614.5001
Landscape Architect:
Wimmer Yamada & Caughey 3067 5th Avenue San Diego, CA 92103 P: 619.232.4004 F: 619.232.0640
Green Roof Consultant:
Jeffrey L. Bruce & Co 1907 Swift St.,Suite 204 N. Kansas City, MO 64116 P: 816.842.8999 F: 816.842.8885
U.S. Department of Commerce, NOAA
10/09/2009
8901 La Jolla Shores Drive La Jolla, California 92037
/1
1/
:4 5:
A
M
QA402
LEVEL 1 - PARTIAL LAB
EQUIPMENT FLOOR PLAN
436784-73621 October 9, 2009
NOAA La Jolla Laboratory Replacement Project
Final Construction Documents
1/4" = 1'-0"1 QA101
A1 Level 1 - Enlarged Plan 3
A GENERAL
1. LAB CASEWORK ON THIS SHEET SHALL BE CONVENTIONAL
PHENOLIC UNLESS OTHERWISE NOTED ON PLANS.
2. ALL TANKS ARE OFOI (NIC).
B ABALONE SUITE
1. HOT/COLD/AMBIENT SEAWATER ADJUSTIBILITY REQUIRED.
2. DEGASSING SYSTEM TO PROVIDE CLEAN STERILIZED
SEAWATER.
3. CLEAN DRY AIR REQUIRED.
4. OXYGEN (O2) CYLINDER SUPPLY.
5. YSI MONITORING SYSTEM WITH LAN ACCESS REQUIRED.
6. TEMPERATURE RANGE: 40°F - 85°F
7. HOURS OF OPERATION: 24/7
8. CEILING HEIGHT: 12'-0"
9. CONVENTIONAL STAINLESS STEEL CASEWORK IN THIS SUITE.
C AQUARIA
1. SEAWATER SYSTEM WITH SAND FILTRATION, CHARCOAL
FILTRATION, UV STERILIZER; OZONE STERILIZER, DE-GASSER
COLUMN, HEATER AND CHILLER.
2. YSI MONITORING SYSTEM WITH LAN ACCESS REQUIRED.
3. CLEAN DRY AIR REQUIRED.
4. OXYGEN (02) CYLINDER SUPPLY.
5. TEMPERATURE RANGE: 40°F - 85°F
D NECROPSY
1. ALL HCW SERVICE FIXTURES SHALL BE FOOT-CONTROLLED.
2. THIS ROOM SHALL HAVE CONVENTIONAL STAINLESS STEEL
CASEWORK.
0' 2' 4' 8' 16'
Number Revision Description Date
1 Amendment 2 12/09/2009
| A030-Amendment 2 |
| A040-Amendment 2 |
| M131-Amendment 2 |
| M141-Amendment 2 |
| M303-Amendment 2 |
| E131-Amendment 2 |
| E141-Amendment 2 |
| E222-Amendment 2 |
| E231-Amendment 2 |
| E232-Amendment 2 |
| E241-Amendment 2 |
| E404-Amendment 2 |
| QA301-Amendment 2 |
| QA402-Amendment 2 |
File details come from the government source that posted it. Updated .