A8-689-19-411_06_Arch_02240718.pdf

PDF 14 MB Posted

Attached to
Y1DZ--Construct Inpatient Pharmacy West Haven Minor Construction 689-411 Federal contract opportunity
Solicitation number
36C77624B0030
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document is a solicitation for a firm-fixed-price contract to construct a new inpatient pharmacy at the Department of Veterans Affairs (VA) West Haven Medical Center in West Haven, CT. The project involves constructing a two-story, 10,500 square foot addition to Building 1 that will house the new inpatient pharmacy on the first floor and mechanical space on the second floor. The work includes general construction, alterations, demolition, and removal of asbestos-containing materials and lead-based paint. The solicitation will be issued as an Invitation for Bid (IFB) under a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside, with an expected contract value between $20-50 million. The period of performance is approximately 730 calendar days from the Notice to Proceed. All questions must be submitted in writing to the VA Technology Acquisition Center Austin.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DZ--Construct Inpatient Pharmacy West Haven Minor Construction 689-411, newest first.
File Type Posted
A23-Price Schedule BLANK.docx DOCX document
Amendment 0003.pdf PDF
A22-Price Schedule EXAMPLE.pdf PDF
A21-Wage Rates SEP24.pdf PDF
A17- RFI responses.pdf PDF
Amendment 0002.pdf PDF
A20-VACHS West Haven Campus Map.pdf PDF
A19-11 24 26 Safety Tie Backs.pdf PDF
A18-Bid Opening Information.pdf PDF
A16- Site Visit Sign in sheet 9-5-24.pdf PDF
Amendment 0001.pdf PDF
A3-689-19-411_01_Spec_20240718.pdf PDF
A5-689-19-411_03_General_02240718.pdf PDF
A13-Limitations on Subcontracting-Construction.docx DOCX document
A1-WestHavenCampusMap.pdf PDF
A10-689-19-411_08_MEP_02240718.pdf PDF
A14-Construction Estimate Breakdown-BLANK.xlsx XLSX spreadsheet
36C77624B0030.pdf PDF
A2-SOW.pdf PDF
A4-689-19-411_02_Spec_20240718.pdf PDF
A6-689-19-411_04_Civil_02240718.pdf PDF
A9-689-19-411_07_Interior_02240718.pdf PDF
A11-Connecticut Tax language.docx DOCX document
A15-Wage Rates AUG24.pdf PDF
A7-689-19-411_05_Struct_02240718.pdf PDF
A12-SPECIAL NOTE -BID TAXES.docx DOCX document
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

ARCHITECTURAL SYMBOLS

SHEET NUMBER

A-100 Sheet Number

Discipline Code

A-1 1/8" = 1'-0"

View Name

VIEW TITLE

Drawing Scale

Drawing Number

1/8" = 1'-0"

View NameA-1 A101R101

VIEW TITLE WITH REFERENCES

Drawing Scale

Sheet Number

Drawing Number

Reference Sheet Number

EXTERIOR ELEVATIONS

INTERIOR ELEVATIONS

A-200

A1 Position on Sheet

Sheet Number

Position on Sheet

Sheet Number

A1

A2B2

B1

A-350

MATCH LINES

MATCHLINE

SEE: A1/A-101B

Sheet Number

Position on Sheet

AREA REFERENCE

A

SEE: (X/X-XXX)

Reference to Area

View Reference for Additional Information

BUILDING SECTION

Position on Sheet

Sheet Number

SIM

X

X-XXX

SIM

X

X-XXX

WALL SECTION

Position on Sheet

Sheet Number

X

X-XXX

SIM

DETAIL - SECTION

SIM

X

X-XXX

Position on Sheet

Sheet Number

DETAIL - PLAN/RCP

SIM

X

X-XXX

Position on Sheet

Sheet Number

DRAWING REVISIONS

Revision Number

NORTH ARROW

True North

PLAN

NORTH

NORTH

TRUE

Plan North

0 4'-0" 8'-0" 16'-0"

IF THIS IS NOT A 42"x30" SHEET IT IS A

REDUCED SIZE PLOT, USE GRAPHIC

SCALE ACCORDINGLY.

GRAPHIC SCALE

COLUMN GRID LINES

Column Grid Line (New)

Column Grid Line (Existing)

1 2

A

B

LEVEL DATUM

LEVEL XX

0' - 0"

Level Name

Level Elevation

SPOT ELEVATION

0'-0"

Spot Elevation

ROOM TAG

ROOM

NAME

ABC123

150 SF

Room Name

Room Number

CEILING TAG

Type Mark

1' - 0" AFF

Ceiling Type

Ceiling Height

DOOR NUMBER TAG

New Door Door Number Tag

1A

Existing Door Door Number Tag

1A101

WINDOW TAG

Interior Window Tag

XX

XX

Exterior Window Tag

CURTAIN WALL TAG

XX

Interior Curtain Wall Tag

Exterior Curtain Wall Tag

XX

AD100

Room Code Room Area Or Volume

1T

CURTAIN PANEL TAG

Interior Curtain Wall Tag

WALL TYPE TAG

≠ A# B

C

V V ITEM -

VA Supplied & Installed

V C ITEM -

VA Supplied & Contractor Installed

C C ITEM -

Contractor Supplied & Installed

FFE Tag (By JSN)A1000

FEC FFE Tag Furnished By VA Equipment Vendor

? KEYNOTE

1"

R 1/2"

90°

DIMENSION TO FACE OF

FINISH, FACE OF CONCRETE,

COLUMN CENTERLINE, OR AS

NOTED.

DIMENSIONS

1"

Symbol Indicates No Sound

Attenuation

Partition Type

CMU/Stud Width

Partition Modifier Partition Modifier II

KEYNOTE TAG

SEE A-720 STANDARD PARTITION TYPES

Contract Limit line Style

Not In Contract Area

CONTRACT LIMIT GRAPHIC

LINE STYLES

Centerline

Demolished

Temporary

Hidden

Overhead

Matchline

FURNITURE, FIXTURE, & EQUIPMENT

8'-6"1

Name

Room Name Room Number

Existing Finish Key

Ceiling Height

FEC Toilet Accessory Tag. See A-730

Deduct alt

MATERIALS LEGEND

CONCRETE (SECTION)

GRANULAR FILL

CONCRETE MASONRY UNITS

BRICK

RIGID INSULATION (SECTION)

ACOUSTIC/THERMAL INSULATION (SECTION)

STEEL (SECTION)

ALUMINUM (SECTION)

WOOD FINISH (SECTION)

LUMBER FINISH (SECTION)

EARTHWORK (SECTION)

STUD WALL (PLAN & SECTION)

EXISTING WALL TO REMAIN (PLAN & SECTION)

DEMOLISHED WALL (PLAN &

SECTION)

EXISTING TO REMAIN

EXISTING TO BE REMOVED

EXISTING TO REMAIN

NEW CONSTRUCTION

DOOR NUMBER

SYMBOL AND MINIMUM

CLEARANCES

18" MIN.

12" MIN.

6" MIN.

1A

WALL LEGEND

REFLECTED CEILING SYMBOLS

SMOKE DETECTOR

SPEAKER

HVAC RETURN DIFFUSER

EXIT LIGHT

HEAT DETECTOR

HVAC EXHAUST DIFFUSER

LINEAR LUMINAIRE

RECESSED ROUND DOWNLIGHT

LUMINAIRE - INSTALL CENTERED IN

ACOUSTICAL CEILING TILE UNO

RECESSED LUMINAIRE (24x48)

ACOUSTICAL TILE CEILING (24x24)

ACOUSTICAL TILE CEILING (24x48)

GYPSUM BOARD CEILING

ACCESS PANEL

HVAC SUPPLY DIFFUSER

SPRINKLER

SURFACED MOUNTED LUMINAIRE

(12x48)

WALL PACK

SD

INDOOR AC UNIT

SECURITY

CAMERA

FIRE ALARM

STROBE

S

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - THE A&E GROUP

100 Pearl Street, 14th Floor

Hartford, CT, 06103

860-270-0753

Mat Perkins

B

IM

/6

-1

-4

C o n s tr u c t N e w

I n p a ti e n t P h a rm a c y /6

-1

-4

.0 .A

R C

H .A

B l o c a ti o n .r v t

/9

/2

:1

:3

P M

A-001

ARCHITECTURAL SYMBOLS, & GENERAL NOTES 689-411

B1

07/18/2024 M. PERKINS S.POLLARD

ISSUED FOR BIDDING CONSTRUCT NEW

INPATIENT PHARMACY

950 CAMPBELL AVENUE WEST HAVEN, CT 06516

ABBREVIATIONS

° DEGREE

± PLUS/MINUS

⌀ DIAMETER

≈ ALMOST EQUAL

∠ ANGLE

℄ CENTER LINE

Δ DELTA, DEFLECTION

ϕ ELECTRICAL PHASE

≠ NOT EQUAL

Ω OHM, OMEGA

BOUNDARY LINE

FLOW LINE

≡ IDENTITY

INITIAL LENGTH

MOMENT LINE

PROPERTY LINE, PLATE

½ ONE HALF FRACTION

¼ ONE QUARTER FRACTION

¾ THREE QUARTERS FRACTION

> GREATER THAN

≥ GREATER THAN OR EQUAL TO

< LESS THAN

≤ LESS THAN OR EQUAL TO

ABCDEFGHIJKMNOPQRSTUVWXYZ 1234567890

A LABEL CLASS A DOOR

A/C AIR CONDITION

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAMA AMERICAN ARCHITECTURAL

MANUFACTURERS ASSOCIATION

AB ANCHOR BOLT, AUGER BORING

ABA ARCHITECTURAL BARRIERS ACT

ABC AGGREGATE BASE COURSE

ABS AIR BREAK SWITCH

AC ASBESTOS CEMENT OR ASPHALTIC

CONCRETE, ACCESS CONTROL DEVICE

ACB AIR CIRCUIT BREAKER

ACI AMERICAN CONCRETE INSTITUTE

ACS DR ACCESS DOOR

ACS FLR ACCESS FLOOR

ACS PNL ACCESS PANEL

ACSR ALUMINUM CONDUCTOR STEEL

REINFORCED

ACST ACOUSTIC

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

ADC AUTOMATIC DOOR CLOSER

ADDL ADDITIONAL

ADDN ADDITION

ADH ADHESIVE

ADJ ADJACENT, ADJOINING, OR

ADJUSTABLE

ADMIN ADMINISTRATION

ADB AUTOMATIC DOOR BOTTOM

ADO AUTOMATIC DOOR OPERATOR

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGA AMERICAN GAS ASSOCIATION

AGC ASSOCIATED GENERAL CONTRACTORS

AGGR AGGREGATE

AHJ AUTHORITY HAVING JURISDICTION

AHR ANCHOR

AHU AIR HANDLING UNIT

AIA AMERICAN INSTITUTE OF ARCHITECTS

AISC AMERICAN INSTITUTE OF STEEL

CONSTRUCTION

AL ALUMINUM

ALT ALTERNATE

ALT NO ALTERNATE NUMBER

ALUM ALUMINUM

AM ACOUSTIC MATERIAL

AMP AMPERE

AMT AMOUNT

ANOD ANODIZE

ANSI AMERICAN NATIONAL STANDARDS

INSTITUTE

ANT ANTENNA

AP ACCESS PANEL, APPROX.,

APPROXIMATE

APA AMERICAN PLYWOOD ASSOCIATION

APPD APPROVED

APPROX APPROXIMATE

APT APARTMENT

AR AS REQUIRED

ARR ARRESTOR

ARCH ARCHITECT, ARCHITECTURAL

ASB ASBESTOS

ASI ARCHITECT'S SUPPLEMENTAL

INSTRUCTION

ASKLR AUTOMATIC SPRINKLER

ASPH ASPHALT

ASSN ASSOCIATION

ASTM AMERICAN SOCIETY FOR TESTING AND

MATERIALS

ATCH ATTACHMENT

ATM AUTOMATIC TELLER MACHINE

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AVE AVENUE

AVG AVERAGE

AW ACID WASTE

AWI ARCHITECTURAL WOODWORKING

INSTITUTE

AWPA AMERICAN WOOD PRESERVERS'

ASSOCIATION

AWS AMERICAN WELDING SOCIETY

AWT ACOUSTICAL WALL TREATMENT

B BASELINE, BOTTOM

B LABEL CLASS B DOOR

B PL BASE PLATE

BALC BALCONY

BAT BATTEN

BB BULLETIN BOARD

BD BOARD

BD FT BOARD FEET (FOOT)

BEJ BRICK EXPANSION JOINT

BEV BEVEL

BHMA BUILDER'S HARDWARE

MANUFACTURER'S ASSOCIATION

BI FLD DR BIFOLDING DOORS

BITUM BITUMINOUS

BKG BACKING

BLD BUILD

BLDG BUILDING

BLKT BLANKET

BLVD BOULEVARD

BM BEAM OR BENCHMARK

BO BOARD

BOT BOTTOM

BR BEDROOM, BOTTOM REGISTER

BRCG BRACING

BRDG BRIDGING

BRDG JST BRIDGING JOIST

BRG BEARING

BRG PL BEARING PLATE

BRKT BRACKET

BRZ BRONZE

BSMT BASEMENT

BTWN BETWEEN

BU BUSHEL

BUR BUILT-UP ROOFING

C CELSIUS, CHANNEL

C CONC CAST CONCRETE

C LABEL CLASS C DOOR

C TO C CENTER TO CENTER

CAB CABINET

CAC CEILING ATTENUATION CLASS

CB CATCH BASIN, CORNER BEAD, CIRCUIT

BREAKER

CBB CEMENTITIOUS (BACKER) BOARD

CC CUBIC CENTIMETER, CONTRACTOR

SUPPLIED & INSTALLED

CCTV CLOSED CIRCUIT TELEVISION

CCW COUNTERCLOCKWISE

CD CONSTRUCTION DOCUMENTS,

CONTRACT DOCUMENTS, CEILING

DIFFUSER

CEM CEMENT

CEM PLAS CEMENT PLASTER

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED /

CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER

INSTALLED

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CENTER OF GRAVITY, CORNER GUARD

C&G CURB AND GUTTER

CGSFU CERAMIC GLAZED STRUCTURAL

FACING UNITS

CH CHILLER

CH BD CHALKBOARD

CHEM CHEMICAL

CHFR CHAMFER

CHK CHECK

CI CAST IRON

CIP CAST-IN-PLACE

CIR CIRCLE

CIRC CIRCULAR

CJ CONSTRUCTION JOINT OR CONTROL

JOINT

CL CENTER LINE

CLDG CLADDING

CLG CEILING

CLG HT CEILING HEIGHT

CLR CLEAR

CM² SQUARE CENTIMETER

CM³ CUBIC CENTIMETER

CM CONSTRUCTION MANAGEMENT

CMP CORRUGATED METAL PIPE

CMPA CORRUGATED METAL PIPE ARCH

CMU CONCRETE MASONRY UNIT

CND CONDUIT

CNDS CONDENSATE

CNR CORNER

CNTR COUNTER

CO CARBON MONOXIDE, CERTIFICATE OF

OCCUPANCY, CLEANOUT, OR COMPANY

CO2 CARBON DIOXIDE

CODP CLEANOUT W/ DECK PLUG

COL COLUMN

COM COMMON

COMB COMBINATION, COMBINED

COMM COMMUNICATION

COMP COMPONENT

CONC CONCRETE

CONC FLR CONCRETE FLOOR

COND CONDENSER OR CONDITION

CONF CONFERENCE

CONN CONNECT, CONNECTION

CONSTR CONSTRUCTION

CONT CONTINUE

CONTR CONTRACTOR, CONTRACTION

COORD COORDINATE

COR CONTRACTING OFFICER'S

REPRESENTATIVE

CORR CORRIDOR

CP NON-REINFORCED CONCRETE PIPE

CPM CRITICAL PATH METHOD

CPRS COMPRESSIBLE

CPT CARPET

CR CHAIR, CRASH RAIL

CRS COLD ROLLED STEEL

CRSI CONCRETE REINFORCING STEEL

INSTITUTE

CS CONCRETE SEALER/SURFACE

CSB CONCRETE SPLASH BLOCK

CSG CASING

CSI CONSTRUCTION SPECIFICATIONS

INSTITUTE

CSK COUNTER SUNK

CSMT CASEMENT

CSWK CASEWORK

CT CERAMIC TILE, CURRENT

TRANSFORMER, COOLING TOWER

CTB CERAMIC TILE BASE

CTF CERAMIC TILE FLOOR

CTG COATING

CTR CENTER, CONTOUR, COOLING TOWER

RETURN

CTRL CONTROL

CTV CABLE TELEVISION

CU COPPER C

CUH CABINET UNIT HEATER

CU FT CUBIC FEET

CU IN CUBIC INCH

CU YD CUBIC YARD

CURT CURTAIN

CW COLD WATER

CWB CAPILLARY WATER BARRIER

CWR COLD WATER RETURN

CYL CYLINDER

CYL L CYLINDER LOCK

D DEPTH OR PENNY (NAIL)

D LABEL CLASS D DOOR

DAT DATUM

DB DECIBEL, DRY BUILT, DIRECT BURIAL

DBL DOUBLE

DBL GLZ DOUBLE GLAZE

DC DIRECT CURRENT

DD DIVERSION DIKE

DEG, ° DEGREE

DEL DELETE

DEMO DEMOLITION

DEML DELAYED EGRESS MAGNETIC LOCK

DEPH DELAYED EGRESS PANIC EXIT DEVICE

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DI DUCTILE IRON

DIA, DIAMETER

DIAG DIAGONAL DIAGRAM

DIAG DIAGRAM DIAGONAL

DIFF DIFFERENCE OR DIFFUSER

DIM DIMENSION

DIR DIRECTION

DISP DISPENSER

DIST DISTANCE

DIV DIVIDE OR DIVISION

DL DEAD LOAD

DMPR DAMPER

DN DOWN

DP DISTRIBUTION

DPS DOOR POSITION SWITCH

DOC DOCUMENT

DOUG FIR DOUGLAS FIR

DOZ DOZEN

DR DOOR, DRAIN, DRESSING ROOM, OR

DRIVE

DR CL DOOR CLOSER

DR FR DOOR FRAME

DR OPNG DOOR OPENING

DS DOWNSPOUT, STORM DRAINAGE

STRUCTURE

DSGN DESIGN

DW DISHWASHER, DOMESTIC WATER

DWD DRINKING WATER DISPENSER

DWG DRAWING

DWTR DUMBWAITER

E EAST

E LABEL CLASS E DOOR

EA EACH

EAM EXCEPT AS NOTED

EAT ENTERING AIR TEMPERATURE

EF EACH FACE, EXHAUST FAN

EFF EFFICIENCY

EFS EXTERIOR FINISH SYSTEM

EG EXHAUST GRILLE

EIFS EXTERIOR INSULATION AND FINISH

SYSTEM

EJ EXPANSION JOINT

EL ELEVATION, ELECTRIC LOCK OR

ELECTRIC LEVER EXIT DEVICE

ELAST ELASTOMERIC

ELEC ELECTRIC

ELEC DR OP ELECTRIC DOOR OPENER

ELEV ELEVATOR

ELR ELECTRIC LATCH RETRACTION EXIT

DEVICE

EMCH ELECTRO-MECHANICAL CLOSER-HOLDER

EMER EMERGENCY

EMER SHR EMERGENCY SHOWER

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

ENGR ENGINEER

ENVIR ENVIRONMENT

E/P EDGE OF PAVEMEMNT

EPA ENVIRONMENTAL PROTECTION

AGENCY

EPDM ETHYLENE PROPYLENE DIENE

MONOMER

EPO EMERGENCY POWER OFF

EPS EXPANDED POLYSTYRENE BOARD

(INSULATION)

EQ EQUAL

EQL SP EQUALLY SPACED

EQUIP EQUIPMENT

EQUIV EQUIVALENT

ER EXHAUST REGISTER

ERD EXISTING ROOF DRAIN

ES ELECTRIC STRIKE

ESC ESCAPE OR ESCUTCHEON

ESCAL ESCALATOR

ESMT EASEMENT

ESP ESPECIALLY

EST ESTIMATE

ETC AND SO FORTH OR ET CETERA

EVAP EVAPORATIVE

EW EACH WAY

EWC ELECTRIC WATER COOLER

EWS EYE WASH STATION

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION OR EXPOSED

EXP BT EXPANSION BOLT

EXP JT EXPANSION JOINT

EXST GR EXISTING GRADE

EXT EXTERIOR, EXTERNAL, OR

EXTINGUISHER

EXT GR EXTERIOR GRADE

F FAHRENHEIT, FEMALE, FIRE, FUSE,

FILTER

FA FIRE ALARM

FAB FABRIC

FABX FIRE ALARM BOX

FAC FACTOR

FACIL FACILITY

FAS FASCIA

FAS BD FASCIA BOARD

FCO FLOOR CLEANOUT

FCTY FACTORY

FD FLOOR DRAIN, FIRE DAMPER

FDC FIRE DEPARTMENT CONNECTION

FDN FOUNDATION

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FF&E, FFE FURNITURE, FIXTURE, AND EQUIPMENT

FH FLAT HEAD, FLAT HEAD SCREWS, FIRE

HYDRANT

FHC FIRE HOSE CABINET

FHMS FLAT HEAD MACHINE SCREW

FHP FULL HEIGHT PARTITION

FHWS FLAT HEAD WOOD SCREW

FIG FIGURE

FIL FILLET

FIN FINISH

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIN WD FINISH WOOD

FIXT FIXTURE

FJ FELT JOINT

FL FLOORLINE, FLOOR, FLASHING, FLOW

LINE

FLASH FLASHING

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLR FLOOR

FLR FIN FLOOR FINISH

FLR SK FLOOR SINK

FLUOR FLUORESCENT

FLUOR FIX FLUORESCENT FIXTURE

FM FACTORY MUTUAL

FM-G FACTORY MUTUAL GLOBAL

FO FINISHED OPENING

FOC FACE OF CONCRETE OR FACE OF CURB

FOF FACE OF FINISH

FOM FACE OF MASONRY

4 WAY FOUR WAY

FOS FACE OF SLAB OR FACE OF STUD

FOUNT FOUNTAIN

FOW FACE OF WALL

FP FIRE PROTECTION OR FIREPROOF

FPH FROST PROOF HYDRANT

FPM FEET PER MINUTE

FPS FEET PER SECOND

FR FIRE RATING, FIRE RESISTANT, OR

FRAME

FR SNK FLUSHING RIM SINK

FREQ FREQUENCY

FRMG FRAMING

FRP FIBER REINFORCED POLYESTER OR

FIBERGLASS REINFORCED PLASTIC

FRZ FREEZER

FS FEDERAL SPECIFICATION, FULL SIZE,

FAIL SAFE

FSE FAIL SECURE

FSTNR FASTENER

FT FEET OR FOOT

FTG FOOTING

FURG FURRING

FURN FURNISH OR FURNITURE

FUT FUTURE

FW FIRE WATER

FWC FABRIC WALLCOVERING

G GROUND, GAS LINE, GRAM

GA GAGE OR GYPSUM ASSOCIATION

GAL GALLON, GALVANIZED

GALV GALVANIC OR GALVANIZED

GALV STL GALVANIZED STEEL

GB GRAB BAR

GC GENERAL CONTRACTOR, GLAZED

COATING

GD GUARD

GDR GUARD RAIL

GEN GENERAL OR GENERATOR

GFI GROUND FAULT INTERRUPT

GFMU GROUND FACE MASONRY UNIT

GFRC GLASS-FIBER-REINFORCED CONCRETE

GFRG GLASS-FIBER-REINFORCED GYPSUM

GFRP GLASS-FIBER-REINFORCED PLASTIC

GI GALVANIZED IRON

GL GLASS

GLZ-C GLAZED BLOCK-CMU

GLZ-T GLAZED BLOCK-CLAY TILE

GL BLK GLASS BLOCK

GLU LAM GLUED LAMINATED WOOD

GR GRADE

GR FL GROUND FLOOR

GRAN GRANITE

GRTG GRATING

GSB GYPSUM SHEATHING BOARD

GSM GALVANIZED SHEET METAL

GSU GLAZED STRUCTURAL UNIT

GT GROUT

GUAR GUARANTEE

GUT GUTTER

GW GROUND WATER

GWB GYPUSM WALL BOARD

GYP GYPSUM

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

H HIGH, HEIGHT, HUMIDIFIER

H PLAM HIGH PRESSURE PLASTIC LAMINATE

HAC HOUSEKEEPING AIDS CLOSET

HAZ MAT HAZARDOUS MATERIALS

HB HOSE BIBB

HC HOLLOW CORE, HANDICAPPED

HCWD HOLLOW CORE WOOD DOOR

HD HARD DRAWN

HDBD HARDBOARD

HDNR HARDENER

HDO HIGH DENSITY OVERLAY

HDR HEADER

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR

(FILTER)

HEX HEXAGON

HF HIGH FREQUENCY

HGR HANGER

HGSW HORN GAP SWITCH

HID HIGH INTENSITY DISCHARGE

HM HECTOMETER

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HMDF HOLLOW METAL DOOR AND FRAME

HMF HOLLOW METAL FRAME

HNDRL HANDRAIL

HO HOLD OPEN

HORIZ HORIZONTAL

HOSP HOSPITAL

HP HIGH PRESSURE, HIGH POINT,

HORSEPOWER

HPS HIGH PRESSURE SODIUM

HQ HEADQUARTERS

HR HOUR

HS HEAT-STRENGTHENED (GLASS) OR

HIGH STRENGTH

HSE HOUSE

HSKPG HOUSEKEEPING

HST HOIST

HT HEIGHT

HVAC HEATING, VENTILATING, AND AIR

CONDITIONING

HVY HEAVY

HW HOT WATER, HEAD WALL

HYD HYDRANT

HYDR HYDRAULIC

HZ HERTZ

I INTERSTATE (HIGHWAY) OR MOMENT

OF INERTIA

IAQ INDOOR AIR QUALITY

IBC INTERNATIONAL BUILDING CODE

ID IDENTIFICATION, INSIDE DIAMETER, OR

INTERIOR DESIGN

ID NO IDENTIFICATION NUMBER

IE INVERT ELEVATION

ILLUM ILLUMINATION

IMC INTERMEDIATE METAL CONDUIT

INCL INCLUDED

IND INDEPENDENT OR INDUSTRIAL

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

INTERCOM INTERCOMMUNICATION

INTL INTERNATIONAL

INV INVERT

IP INLET PROTECTION

IRBF INDUSTRIAL RESIN BASE FLOORING

IRMA INVERTED ROOF MEMBRANE ASSEMBLY

IWH INSTANTANEOUS WATER HEATER

JAN JANITOR

J-BOX, JB JUNCTION BOX

JC JANITOR CLOSET

JCT JUNCTION

JT JOINT

JST JOIST

K KILO

KCP KEENE'S CEMENT PLASTER

KD KILN DRIED OR KNOCKED DOWN

KG KILOGRAM

KN KILONEWTON

KIT KITCHEN

KO KNOCKOUT

KPL KICKPLATE

KV KILOVOLT

KVA KILOVOLT-AMPERE

KW KILOWATT

L ANGLE, LOUVER, LENGTH, LENGTH OF

CURVE

LA LIGHTING ARRESTOR

LAB LABORATORY

LAD LADDER

LAM LAMINATE

LAM GL LAMINATED GLASS

LAU LAUNDRY

LAV LAVATORY

LBR LUMBER

LBS POUND

LC LEAD COVERED

LD BRG LOAD-BEARING

LDR LEADER

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LH LEFT HAND

LHR LEFT HAND REVERSE

LHR LEFT HAND REVERSE, LATENT HEAT

RATIO

LIB LIBRARY

LIN LINEAR

LINO LINOLEUM

LIQ LIQUID

LKR LOCKER

LKR RM LOCKER ROOM

LKWASH LOCKWASHER

LL LEAD LINED, LIVE LOAD

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LMST LIMESTONE

LNDSCP LANDSCAPE

LR LIVING ROOM

LRG LARGE

LRV LOUVERED ROOF VENT

LS LUMP SUM

L/S LITERS PER SECOND

LT LIGHT

LT GA LIGHT GAGE

LT WT LIGHTWEIGHT

LTG LIGHTING

LTNG LIGHTNING

LVC LENGTH OF VERTICAL CURVE

LVD LOUVERED

LVR LOUVER

LWC LIGHTWEIGHT CONCRETE

LWIC LIGHTWEIGHT INSULATING CONCRETE

LYR LAYER

M METER, MEGA

MACH MACHINE

MACH RM MACHINE ROOM

MAINT MAINTENANCE

MAN MANUAL

MAS MASONRY

MATL MATERIAL

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MB MACHINE BOLT

MCB METAL CORNER BEAD

MD METAL DECK

ME MECHANICAL ENGINEER

MEAS MEASURE

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MED MEDICAL, MEDIUM

MEK METHYL ETHYL KETONE

MEL MELAMINE

MEMB MEMBRANE

MEMO MEMORANDUM

MEZZ MEZZANINE

MF MILL FINISH

MFD MANUFACTURED

MFG MANUFACTURING

MFR MANUFACTURER

MFR REC MANUFACTURER'S RECOMMENDATION

MGT MANAGEMENT

MH MANHOLE

MHO MAGNETIC HOLD OPEN

MIC MICROPHONE

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM MINUTE

MIN MINUTE MINIMUM

MIRR MIRROR

MISC MISCELLANEOUS

MIT MITER

MKR MARKER

ML METAL LATH

MLDG MOLDING (MOULDING)

MLO MAIN LUG ONLY

MLWK MILLWORK

mm MILLIMETER

MMP MEMBRANE WATERPROOFING

MO MASONRY OPENING OR MOTOR

OPERATED

MOD MODEL, MODIFY OR MODULE

MOD BIT MODIFIED BITUMEN

MON MONITOR

MOPR MOP RACK

MP MEDIUM PRESSURE

MR MOISTURE RESISTANT

MS MACHINE SCREW OR MOP SINK

M/S METERS PER SECOND

MTD MOUNTED

MTG MOUNTING

MTL METAL

MULL MULLION

MW MICROWAVE

MWP MEMBRANE WATERPROOFING

N NORTH

NA NOT APPLICABLE

NAAMM NATIONAL ASSOCIATION OF

ARCHITECTURAL METAL

MANUFACTURERS

NAT NATURAL

NATL NATIONAL

NC NOISE CRITERIA, NON-CORROSIVE

NCOMBL NONCOMBUSTIBLE

NDC NOSE DOWN CURB

NE NORTHEAST

NEC NATIONAL ELECTRICAL CODE

NEG NEGATIVE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION

NEUT NEUTRAL

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NPS NOMINAL PIPE SIZE

NR NOISE REDUCTION

NRC NOISE REDUCTION COEFFICIENT

NRCA NATIONAL ROOFING CONTRACTORS

ASSOCIATION

NRP NON-REMOVABLE

NS NARROW STILE

NTS NOT TO SCALE

NUM NUMERAL

NW NORTHWEST

O/O OUT TO OUT

O OXYGEN

OA OUTSIDE AIR OR OVERALL

OC ON CENTER

OCB OIL CIRCUIT BREAKER

OCC OCCUPY

OCT OCTAGON

OD OUTSIDE DIAMETER OUTSIDE

DIMENSION

OD OUTSIDE DIMENSION OUTSIDE

DIAMETER

OF/CI OWNER FURNISHED/CONTRACTOR

INSTALLED

OFD OVERFLOW DRAIN

OFF OFFICE

OF/OI OWNER FURNISHED/OWNER INSTALLED

OH OVERHANG, OVERHEAD

OH DR OVERHEAD (COILING) DOOR

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

OPT OPTIONAL

OR OPERATING ROOM, OUTSIDE RADIUS

ORD ORDNANCE OR OVERFLOW ROOF

DRAIN

ORG ORGANIC

ORIG ORIGINAL

ORN ORNAMENTAL

OSD OPEN SITE DRAIN

OSHA OCCUPATIONAL SAFETY AND HEALTH

ADMINISTRATION

OVHD OVERHEAD

OUT OUTLET

OZ OUNCE

P PIPE, POLE

Pa PASCALES

PA PUBLIC ADDRESS

PAR PARALLEL OR PARAPET

PARA PARAGRAPH

PART PARTIAL

PAT PATTERN

PB PUSHBUTTON, PUSHBUTTON

COMBINATION LOCK (STAND-ALONE)

PULL BOX

PBD PARTICLEBOARD

PC PIECE, POLYCARBONATE, PORTLAND

CEMENT, PRECAST

PCA PORTLAND CEMENT ASSOCIATION

PCC PRECAST CONCRETE

PCCP CONCRETE PAVEMENT

PCD PAPER CUP DISPENSER

PCF POUNDS PER CUBIC FOOT

PCP PORTLAND CEMENT PLASTER

PED PEDESTAL

PEN PENETRATE

PEND PENDANT

PERF PERFORATED

PERIM PERIMETER

PERP PERPENDICULAR

PGBD PEGBOARD

PHAR PHARMACY

PHOTO PHOTOGRAPH

PHS PHILLIPS HEAD SCREW

PI POINT OF INTERSECTION

PIV POST INDICATOR VALVE

PJF PREFORMED JOINT FILLER

PKG PACKAGE

PL PROPERTY LINE, PLATE

PL GL PLATE GLASS

PLAM PLASTIC LAMINATE

PLAS PLASTER OR PLASTIC

PLAS CMU PLASTER COVERED CMU

PLBG PLUMBING

PLYWD PLYWOOD

PMTL PAINTED METAL

PNEU PNEUMATIC

PNL PANEL

PNT PAINT

PO POST OFFICE, PURCHASE ORDER

PO PURCHASE ORDER POST OFFICE

POLY POLYETHYLENE (PLASTIC)

PR PAIR

PRCST PRECAST

PREFAB PREFABRICATE

PREFIN PREFINISH

PRELIM PRELIMINARY

PREP PREPARATION

PRESS PRESSURE

PREV PREVIOUS

PRIM PRIMARY

PRKG PARKING

PRMLD PREMOLDED

PROJ PROJECT

PROP PROPERTY

PRV PRESSURE RELIEF VALVE

PS PULL SWITCH

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT, PNEUMATIC TUBE, PRESSURE

TREATED, POINT OF TANGENT

PTD PAPER TOWEL DISPENSER

PTN PARTITION

PVC POLYVINYL CHLORIDE (PLASTIC), POINT

OF VERTICAL CURVE

PVG PAVING

PVI POINT OF VERTICAL INTERSECTION

PVT POINT OF VERTICAL TANGENT

PVMT PAVEMENT

PWR POWER

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QRY QUARRY

QT QUARRY TILE

QTB QUARRY TILE BASE

QTF QUARRY TILE FLOOR

QTR QUARTER

QTY QUANTITY

QUAD QUADRANT

QUAL QUALITY

R RADIUS, RISER, RUBBER, RETURN

RA RETURN AIR

RAD RADIATOR, RADIUS

RB RESILIENT BASE OR RUBBER BASE

RB HK ROBE HOOK

RBM REINFORCED BRICK MASONRY

RBR RUBBER

RC REMOTE CONTROL

RCP REFLECTED CEILING PLAN,

REINFORCED CONCRETE PIPE

RCVR RECEIVER

RD ROAD OR ROOF DRAIN

REC RECESSED

RECD RECEIVED

RECPT RECEPTACLE

RECT RECTANGLE

RED REDUCING

REF REFERENCE OR REFRIGERATOR

REFR REFRACTORY, REFRIGERATION

REG REGISTER, REGULATOR

REINF REINFORCE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RESIL RESILIENT

RESIL T RESILIENT TILE

RET RETURN

REV REVISION

REX REQUEST-TO-EXIT SWITCH

RF RADIO FREQUENCY, ROOF, RETURN

FAN

RFG ROOFING

RFI REQUEST FOR INFORMATION

RFP REQUEST FOR PROPOSAL

RGS RIGID GALVANIZED STEEL

RH RIGHT HAND

RHC REHEAT COIL

RHMS ROUND HEAD MACHINE SCREW

RHR RIGHT HAND REVERSE

RHWS ROUND HEAD WOOD SCREW

RI RUBBER INSULATED

RL ROOF LEADER

RLG RAILING

RM ROOM

RND ROUND

RO ROUGH OPENING

ROW RIGHT OF WAY

RPM REVOLUTIONS PER MINUTE

RR REMOTE RELEASE BUTTON

RS ROUGH SAWN

RT RIGHT

RV ROOF VENT

RVS REVERSE

RVT RESILIENT VINYL TILE

RWD REDWOOD

RWL RAIN WATER LEADER

S SECOND, SOUTH, SANITARY, SEWER,

STRUCTURE

SA SUPPLY AIR

SALV SALVAGE

SAMP SAMPLE

SAN SANITARY SEWER

SAT SUSPENDED ACOUSTICAL TILE

SATC SUSPENDED ACOUSTICAL TILE CEILING

SB SPLASH BLOCK

SBS STYRENE BUTADIEN STYRENE

SBSTR SUBSTRATE

SC SHADING COEFFICIENT OR SOLID CORE

SCH SCHOOL, SCHEDULE

SCHED SCHEDULE

SCHEM SCHEMATIC

SCP SCUPPER

SCRN SCREEN

SCT STRUCTURAL CLAY TILE

SCWD SOLID CORE WOOD DOOR

SD SHOP DRAWINGS, SMOKE DETECTOR,

OR SOAP DISPENSER;

SDG SIDING

SE SOUTHEAST

SECT SECTION

SEG SEGMENT

SEL SELECT

SEP SEPARATE

SF SQUARE FOOT (FEET)

SFTWD SOFTWOOD

SG SUPPLY GRILLE

SGD SLIDING GLASS DOOR

1PH SINGLE PHASE

SGL SINGLE

SH SHEET

SHR SHOWER

SHR HD SHOWER HEAD

SHRD SHOWER DRAIN

SHT SHEET

SHT MTL FL SHEET METAL (FLASHING)

SHTHG SHEATHING

SHV SHELVING

SIM SIMILAR

SJ SCORED JOINT

SJI STEEL JOIST INSTITUTE

SK SKETCH

SKCP SUSPENDED KEENE'S CEMENT

PLASTER

SKLT SKYLIGHT

SL SLOPE

SLD WDW HORIZONTAL SLIDING WINDOW

SLDG SLIDING

SLNT SEALANT

SM SHEET METAL

SMH SANITARY MODULE

SMK SMOKE

SND SANITARY NAPKIN DISPENSER

SND INS SOUND INSULATION

SNDU SANITARY NAPKIN DISPOSAL UNIT

SP STATIC PRESSURE, SINGLE POLE

SPC SUSPENDED PLASTER CEILING

SPDT SINGLE POLE DOUBLE THROW

SPEC SPECIFICATION

SPKLR SPRINKLER

SPKR SPEAKER

SPST SINGLE POLE SINGLE THROW

SPLY SUPPLY

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SR SUPPLY REGISTER

SS SANITARY SEWER OR SERVICE SINK

SST STAINLESS STEEL

ST STAIRS, STREET, SINGLE THROW

STA STATION

STC SOUND TRANSMISSION CLASS

STD STANDARD

STIF STIFFENER

STL STEEL

STL JST STEEL JOIST

STL LNTL STEEL LINTEL

STL PL STEEL PLATE

STL RF DK STEEL ROOF DECK

STL TB STEEL TUBE

STL TR STEEL TRUSS

STNLS STAINLESS

STOR STORAGE

STR STRINGERS

STRUCT STRUCTURAL

STRUCT STL STRUCTURAL STEEL

SUB SUBSTITUTE

SURF SURFACE

SUP SUPPORT

SUSP SUSPEND

SUSP CLG SUSPENDED CEILING

SV SHEET VINYL

SV B SHEET VINYL BASE

SW SWITCH, SIDE WALK

SWBD SWITCHBOARD

SWDR SWING DOOR

SWGR SWITCH GEAR

SYM SYMBOL

SYNTH SYNTHETIC

SYS SYSTEM

T TREAD, TILE, TOP, TANGENT

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

T&M TIME AND MATERIALS

TB THROUGH BOLT OR TOWEL BAR

TC TOP OF CURB

TCA TILE COUNCIL OF AMERICA

TCP TELEPHONE CONTROL PANEL

TEMPERATURE CONTROL PANEL;

TRAFFIC CONTROL PLAN

TD TOWEL DISPENSER

TECH TECHNICAL

TEL TELEPHONE

TEMP TEMPERATURE OR TEMPORARY

TER TERRAZZO

TERM TERMINAL

TH TOTAL HEAD (PUMPS)

THD THREAD

THERM THERMAL

THK THICKNESS

THRES THRESHOLD

THRSLD THRESHOLD

THRU THROUGH

THRUOUT THROUGHOUT

TK BD TACKBOARD

TMPD TEMPERED

TMPD GL TEMPERED GLASS

TN TRUE NORTH

TO TOP OF ___

TO FDN TOP OF FOUNDATION

TOB TOP OF BEAM

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOS TOP OF STEEL

TOW TOP OF WALL

TPD TOILET PAPER DISPENSER

TPH TOILET PAPER HOLDER

TR TOWEL RACK, TOP REGISTER

TRANS TRANSOM, TRANSITION

TRANS WD FIN TRANSPARENT WOOD FINISH

TRTD TREATED

TS TENSILE STRENGTH, TUBE STEEL, TOP

OF STEEL, TOP OF STONE, TOP OF

SLAB

TSTAT THERMOSTAT

TV TELEVISION

TYP TYPICAL

U HEAT TRANSFER COEFFICIENT

UC UNDERCUT

UCD UNDERCUT DOOR

UCF UNDER COUNTER FREEZER

UCR UNDER COUNTER REFRIGERATOR

UGE UNDERGROUND ELECTRIC

UGND UNDERGROUND

UGT UNDERGROUND TELEPHONE

UH UNIT HEATER

UL UNDERWRITERS LABORATORIES

ULT ULTIMATE

UNFIN UNFINISH

UNO UNLESS NOTED OTHER WISE

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

UR URINAL

UTIL UTILITY

UV ULTRAVIOLET

V VOLT, VENT, VALVE

VA VOLT AMPRE

VAC VACUUM

VAR VARIES

VB VINYL BASE

VC VARNISH CAMBRIC, VITRIFIED CLAY, VA

SUPPLIED & CONTRACTOR INSTALLED

VCT VINYL COMPOSITION TILE, VITRIFIED

CLAY TILE

VEH VEHICLE

VENT VENTILATION

VERT VERTICAL

VEST VESTIBULE

VFAT VINYL FACED ACOUSTICAL TILE

VIC VICINITY

VID VIDEO

VIF VERIFY IN FIELD

VNR VENEER

VOC VOLATILE ORGANIC COMPOUND

VOL VOLUME

VOLT VOLTAGE

VP VENEER PLASTER

VPI VERTICAL POINT OF INTERSECTION

VPOC VERTICAL POINT OF CURVE

VPOT VERTICAL POINT OF TANGENT

VR VAPOR RETARDER

VS VENT STACK

VTR VENT THROUGH ROOF

VV VA SUPPLIED & INSTALLED

VWC VINYL WALL COVERING

VWF VINYL WALL FABRIC

W WIDE, WEST, WIDTH, WASTE, WATER,

WATT, WIRE

W/ WITH

W/O WITHOUT

WA WATT

WARR WARRANTY

WB WET BULB

WBL WOOD BLOCKING

WC WALL COVERING OR WATER CLOSET

WC WL HNG WATER CLOSET, WALL HUNG

WCHR WATER CHILLER

WCL WL MTD WATER COOLER, WALL HUNG

WD WOOD, WINDOW DIMENSION

WDW WINDOW

WF WIDE FLANGE

WFAB WALL FABRIC

WFR WOOD FRAME

WFS WOOD FURRING STRIPS

WH WATER HEATER

WHSE WAREHOUSE

WL WATER LEVEL

WLD WELDED

WM WIRE MESH

WOM WALK OFF MATT

WP WATERPROOFING, WEATHERPROOF

WPD WATER PRESSURE DROP

WPM WATERPROOF MEMBRANE

WR WEATHER RESISTANT

WS WEATHERSTRIP, WASTE STACK, WATER

SURFACE, WATERSTOP

WSCT WAINSCOT

WT WEIGHT

WTB WALL TILE BASE

WTL WALL TILE

WWF WELDED WIRE FABRIC

X BRACE CROSS BRACE

XFMR TRANSFORMER

XPS EXTRUDED POLYSTYRENE BOARD

(INSULATION)

X-STR EXISTING STRUCTURE

YD YARD

YR YEAR

1. ACCESS TO EXISTING FIRE EXITS SHALL REMAIN

OPERATIONAL DURING ALL PHASES OF CONSTRUCTION.

ENSURE ADEQUATE EGRESS CLEARANCES ARE

MAINTAINED AND NOT IMPEDED DURING CONSTRUCTION.

2. GENERAL NOTES APPLY TO ALL DRAWING SETS.

3. SUBCONTRACTORS FOR EACH TRADE ARE ADVISED THAT

INFORMATION PERTINENT TO THEIR WORK MAY OCCUR IN

OTHER PORTIONS OF THE CONTRACT DOCUMENTS. ALL

NOTES ARE TO BE REVIEWED AND APPLIED TO RELATED

BUILDING DOCUMENTS.

4. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.

IF INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS

ARE DISCOVERED FOLLOW PROCEDURES LISTED IN

SECTION 01 26 13 REQUESTS FOR INFORMATION (RFI)

BEFORE AND/OR DURING CONSTRUCTION.

5. CROSS REFERENCES SHOWN ON DRAWINGS DO NOT

NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT

LIMIT APPLICATION OF ANY DRAWING OR DETAIL. WHERE

SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT

CANNOT BE DETERMINED, FOLLOW PROCEDURES LISTED

IN SECTION 01 26 13 REQUESTS FOR INFORMATION (RFI)

PRIOR TO PROCEEDING WITH WORK.

6. REVIEW SPECIFICATIONS FOR INSTRUCTIONS NOT SHOWN

ON DRAWINGS. INFORMATION COMMON TO SEVERAL

DRAWINGS MAY BE NOTED ON ONLY ONE. CONTRACTORS

ARE RESPONSIBLE FOR CONFORMANCE TO ENTIRE SET OF

DOCUMENTS.

7. PATCH ALL HOLES IN EXISTING SURFACES WHERE

EQUIPMENT HAS BEEN REMOVED OR DEMOLITION HAS

OCCURRED AND PREPARE WALL SURFACES (PATCH, SKIM

COAT, PAINT AND FINISH TO MATCH ADJACENT SURFACES)

AS REQUIRED IN PREPARATION FOR NEW FINISHES

SCHEDULED. PATCH TO MATCH ADJACENT SURFACES IF

NOT SCHEDULED.

8. DIMENSIONS ARE TO STRUCTURAL GRIDLINE OR FACE OF

FINISHED WALL UNLESS NOTED OTHERWISE.

9. PROVIDE METAL BACKING AND/OR METAL BLOCKING IN

WALLS AT ALL WALL-MOUNTED ITEMS. VERIFY HEIGHT AND

LENGTH WITH ACTUAL EQUIPMENT. REFER TO METAL

BACKING AND BLOCKING DETAILS ON SHEET A-722. AT

EXISTING WALLS, REMOVE WALL MATERIAL TO INSTALL

METAL BACKING/BLOCKING FOR NEW WALL-MOUNTED

ITEMS.

10. ALL EXISTING FLOOR AND WALL OPENINGS AND

DEPRESSIONS NOT USED IN THE NEW WORK SHALL BE

FILLED OR CLOSED WITH MATERIALS TO MEET REQUIRED

FIRE RATING AND MATCH ADJACENT FINISHES.

11. DRAWINGS ARE NOT TO BE SCALED. CONTRACTOR TO

VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO

COMMENCING THE WORK.

12. COORDINATE WITH INTERIORS SHEETS FOR CORNER

GUARD AND WALL PROTECTION LOCATIONS AND DETAILS.

13. RADIUS EXPOSED COUNTERTOP CORNERS 2" RADIUS,

TYPICALLY. (2" WHERE 3MM EDGE BANDING, 1" RADIUS AT

PLAM EDGES.) SEE CASEWORK DETAILS.

14. CAULK ALL COUNTERTOPS, BACKSPLASHES AND CABINETS

AT LOCATIONS WHERE THEY MEET WALLS. SEAL ALL CUT-

OUTS IN COUNTERTOPS.

15. ALL CUTTING AND PATCHING REQUIRED FOR NEW

MECHANICAL AND ELECTRICAL WORK IN ALL EXISTING

SPACES SHALL BE BY THE RESPECTIVE CONTRACTORS.

16. MATCH ALL FINISHED WALL THICKNESS WHERE NEW

WALLS OCCUR IN-LINE WITH EXISTING WALLS.

17. CONTRACTOR TO PROVIDE FIRE, SMOKE, DIRT, DUST &

NOISE CONTAINMENT BARRIERS BETWEEN THE WORK

AREA & THE ADJACENT OCCUPIED SPACES. COORDINATE

THIS CONTAINMENT WITH ICRA AND ASBESTOS

ABATEMENT PROVISIONS.

18. ALL PIPING, CONDUITS, AND RELATED MECHANICAL AND

ELECTRICAL ITEMS SHALL BE CONCEALED WITHIN

DRYWALL AND/OR PLASTER FURRING AS REQUIRED IN

FINISHED AREAS WHETHER SHOWN ON DRAWINGS OR NOT

UNLESS OTHERWISE NOTED.

19. SEAL AROUND ALL MECHANICAL AND ELECTRICAL

EQUIPMENT PENETRATIONS AT RATED WALLS, ABOVE AND

BELOW CEILINGS, WITH A UL APPROVED FIRE-STOPPING

MATERIAL.

20. ALL INTERIOR WALLS WILL BE TYPE 'S' CONSTRUCTION

UNLESS OTHERWISE INDICATED. ALL FRAMING AROUND

COLUMNS WILL BE TYPE 'L2' CONSTRUCTION UNLESS

OTHERWISE INDICATED.

21. REFER TO PLAN SHEETS GI101 AND GI102 FOR INTENDED

WALL RATINGS.

22. WHEN WALL PARTITIONS OF DIFFERENT FIRE RATING

INTERSECT, THE HIGHEST RATED PARTITION TAKES

PRIORITY.

23. ALL EXISTING TO REMAIN CEILING AND WALL GRILLES,

DIFFUSERS AND LIGHTS, SPRINKLER HEADS, OCCUPANCY

AND FIRE ALARM DETECTORS TO BE CLEANED IN AREAS

OF CONSTRUCTION.

24. VERIFY THAT THE EXISTING WALLS REQUIRING FIRE

RATING ARE MAINTAINED, REPAIRED AND EXTENDED TO

STRUCTURE.

25. ALL THERMOSTAT LOCATIONS TO BE COORDINATED WITH

COR PRIOR TO INSTALLATION.

GENERAL SHEET NOTES:

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE

RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN

GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

Revisions: Date:

PIV

PIV

S S

UP

E ST

D

WH

ARCHITECTURAL SYMBOL LEGEND - DEMO

DEMOLISHED WALL, FIXTURE OR FURNISHING

EXISTING WALL, FIXTURE OR FURNISHING TO REMAIN

GENERAL DEMOLITION NOTES

A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE RATED

WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA. PROVIDE ALL

PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT WALLS SHALL BE

CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED

FIRE PROOF CAULKING MATERIAL. SEE MECHANICAL AND PLUMBING DRAWINGS

FOR ADDITIONAL INFORMATION.

B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND CONDUIT PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

C. EXISTING DEVICES SHOWN DO NOT REPRESENT ALL DEVICES OR EXACT

LOCATIONS. CONTRACTOR TO VERIFY ALL ITEMS ONSITE PRIOR TO BIDDING.

D. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION

WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM THOSE INDICATED.

CONTRACTOR TO FIELD VERIFY IN ADVANCE THE LOCATION AND CONDITION OF

THOSE EXISTING SYSTEMS SHOWN TO BE MODIFIED OR REMOVED.

CONTRACTOR TO NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER

SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.

E. CONTRACTOR TO COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL

TRADES PRIOR TO INSTALLATION.

F. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED AT

CONNECTIONS BETWEEN ALL DISSIMILAR METALS.

G. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS REQUIRED TO

COMPLETE THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND

RETURN TO MATCH EXISTING CONDITIONS AND FINISHES.CONTRACTOR TO

PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED EXTERIOR PIPE PENETRATIONS

AND SEAL COMPLETELY.

H. CONTRACTOR TO PROVIDE TEMPORARY FLOORING WHILE MODIFYING

SUBFLOORING.

I. ANY LANDSCAPE, HARDSCAPE, FIXTURE, SIGNAGE AND SYSTEMS OR

PEDESTRIAN CONTROL DEVICES WITHIN THE TEMPORARY ACCESSIBLE

PATHWAY SHALL BE PROTECTED IN PLACE OR TEMPORARILY RELOCATED AS

NECESSARY FOR CONTINUED UNINTERRUPTED OPERATION, ACCESS,

MAINTENANCE AND / OR VISIBILITY.

J. CONTRACTOR TO DEMO ALL ELECTRICAL, DATA, THERMOSTATS EQUIPMENT.

CAP SYSTEMS APPROPRIATELY FOR FUTURE CONNECTIONS, COORDINATE WITH

MEP.

K. SPRINKLER PROTECTION WITHIN THE CONSTRUCTION AREA THAT IS INTENDED

TO REMAIN AFTER DEMOLITION IS TO BE MAINTAINED. IN AREA OF FULL

DEMOLITION, SPRINKLER PROTECTION SHALL BE MAINTAINED UNTIL TEMPORARY

CONSTRUCTION BARRIER IS COMPLETED.

L. CONTRACTOR TO PROVIDE TEMPORARY EGRESS AND DETOUR SIGNAGE AT ALL

CONSTRUCTION BARRIERS THAT IMPACT NORMAL USE OR EGRESS PATHWAYS

IN THE EXISTING BUILDING OR COURTYARD.

KEYNOTES

NO WORK

EXISTING GRID

DOOR: EXISTING TO REMAIN / TO BE DEMOLISHED

CONSTRUCTION FENCING

CONCRETE PAVING OR SLAB TO BE REMOVED. SEE CIVIL

1X 5X 6X

M-X

P-X

Q-X

R-X

S

T

U

Y

Y'

Z

Z'

BB

CC'

EE

EE'

FF

GG

HH

P'-X

V

AA

CC

DD

2X 3X 4X

W'

X

W

11A

16 17

5' -1

6'

-9

/8

6' -9

/8

11A

F1

A-510

310 SF

SURGICAL

ANATOMIC

PATHOLOGY

153 SF

SUPERVISOR

189 SF

MECH

297 SF

MICROSCOPY

N

B1 KEY PLAN

EXISTING

PHARM

B1

B2

AREA

A

AREA

B

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - THE A&E GROUP

100 Pearl Street, 14th Floor

Hartford, CT, 06103

860-270-0753

Mat Perkins

B

IM

/6

-1

-4

C o n s tr u c t N e w

I n p a ti e n t P h a rm a c y /6

-1

-4

.0 .A

R C

H .A

B l o c a ti o n .r v t

/9

/2

:2

:1

P M

AD101

ARCHITECTURAL FIRST FLOOR DEMOLITION

PLAN

689-411

B1

07/18/2024 M. PERKINS S. POLLARD

ISSUED FOR BIDDING CONSTRUCT NEW

INPATIENT PHARMACY

950 CAMPBELL AVENUE WEST HAVEN, CT 06516

1/8" = 1'-0" F1

ARCHITECTURAL FIRST FLOOR DEMOLITION PLAN

1 CONTRACTOR TO DEMOLISH BUILDING 6A - REMOVING ALL UTILITIES AND ENTRY

STAIRS PRIOR TO CONSTRUCTION. COORDINATE WITH COR PRIOR TO START TO

ENSURE BUILDING OCCUPANTS HAVE BEEN RELOCATED

2 DEMOLISH PORTION OF EXTERIOR WALL AT EXISTING DOORWAY REQUIRED FOR

NEW DOOR INTO NEW HALLWAY

3 DEMOLISH EXISTING WINDOW.

4 DEMOLISH EXISTING SIDEWALK - REFER TO CIVIL

5 EXISTING TREES TO REMAIN; PROTECT IN PLACE; REFER TO CIVIL

6 EXISTING CORRIDOR TO REMAIN IN SERVICE

7 EXISTING RAILING, DUCTWORK AND AREAWAYS TO REMAIN, PROTECT IN PLACE

8 REFER TO CIVIL FOR DEMOLITION AND RELOCATION OF UTILITIES

9 EXISTING EXTERIOR LIGHT FIXTURE TO REMAIN ; REFER TO CIVIL

10 PICNIC TABLE WITH CANOPY - SALVAGE TO OWNER

11 EXISTING EXTERIOR LIGHT FIXTURE TO BE REMOVED ; REFER TO CIVIL

11A EXISTING EXTERIOR LIGHT FIXTURE TO REMAIN; REFER TO CIVIL

12 EXISTING TREES TO BE REMOVED; REFER TO CIVIL

13 EXISTING FIRE HYDRANT TO BE RELOCATED; REFER TO CIVIL

14 EXISTING PIV TO BE REMOVED ; REFER TO CIVIL

15 DEMOLISH EXISTING ELECTRICAL J-BOXES AND CONNECTIONS. REFER TO

ELECTRICAL.

16 EXISTING PORTABLE AC UNIT TO BE RELOCATED; REFER TO CIVIL

17 EXISTING AC UNIT TO BE RELOCATED; REFER TO CIVIL. CONCRETE PAD TO BE

DEMOLISHED.

18 DEMOLISH EXISTING TRANSFORMER - REFER TO ELECTRICAL

19 CONSTRUCT CONSTRUCTION FENCING; REFER TO CIVIL.

20 EXISTING HEDGES TO BE REMOVED.

21 REMOVE STEAM VAULT TO FULLEST EXTENT POSSIBLE. STEAM LINES TO BE SAFETY

DISCONNECTED AND CUT OFF FROM INTERIOR OF SUB-BASEMENT PRIOR TO

REMOVAL OF CONCRETE VAULT. IF REMOVAL OF WALLS ABUTTING EXISTING

FOUNDATION WALLS CANNOT BE ACCOMPLISHED WITHOUT DAMAGE TO EXISTING

FOUNDATION WALLS, RETAINING THAT PORTION OF THE STEAM VAULT SHALL BE

ACCEPTABLE AT THE FINAL DETERMINATION OF THE COR.

22 TEMPORARY CONSTRUCTION BARRIER BUILT PRIOR TO DEMOLITION AND TO BE

REMOVED ONCE ADEQUATE FIRE SEPARATION IS PROVIDED BY NEW

CONSTRUCTION.

23 TEMPORARY CONSTRUCTION EGRESS AND DETOUR SIGNS AT EACH POINT OF

COURTYARD ACCESS IMPACTED BY CONSTRUCTION BARRIERS. CONTRACTOR

SHALL PHASE FENCING AND PROTECTED WORK SUCH THAT AT NO POINT WILL A

DEAD END CONDITION BE PERMITTED.

UP

9X 10X

B

B

E

E

G

G

H

H

K

K

M

M

C

C

J

J

F

F

D

D

F1

A-301

B1

A-302

B5

A-302 A

A

L

L

F1

A-510

F6

A-100

8' -8

/4

'-0

/2

/4

9' -8

/4

2' -3

'-7

/4

1/

2"

'-1

/4

1'-11 7/8" 11'-10 1/4" 1'-3 3/4" 19'-0" 3'-0" 13'-9" 8'-3" 20'-5" 23'-7" 22'-6" 9'-4" 2" 15'-2" 8'-0"

EXPN JT

4" F.O. WALL ABV

'-9

1'

-0

/4

1'-11 7/8"

30'-3 1/2" 1'-10 1/2" 92'-1 1/4" 32'-0 3/4"

1'-0"

5' -0

C

LR

F3

A-100

A-420

F8

UTILITY

TUNNEL

1655 SF

TUNNEL

STAIR

191 SF

6'-0" CLR

0100A

A

B

UTILITY

TUNNEL

01000100

1/ 8"

1'

-0

1/8" / 1'-0"

1/ 8"

1'

-0

1/8" / 1'-0"

FDTN JT 1'-0" ±

A-201

D1

1/16" / 1'-0"1/16" / 1'-0" 3"

0" -1"

0"

-1" 0" -1/2"

-1/2"

3'-0"

5' -4

/4

ELECTRICAL

MANHOLE

E0000E0000

ARCHITECTURAL SYMBOL LEGEND

GENERAL SHEET NOTES

KEYNOTES

KEY PLAN

A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE RATED

WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA. PROVIDE ALL

PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT WALLS SHALL BE

CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED

FIRE PROOF CAULKING MATERIAL. SEE MECHANICAL AND PLUMBING DRAWINGS

FOR ADDITIONAL INFORMATION.

B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND CONDUIT PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

C. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION

WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM THOSE INDICATED.

CONTRACTOR TO FIELD VERIFY IN ADVANCE THE LOCATION AND CONDITION OF

THOSE EXISTING SYSTEMS SHOWN TO BE MODIFIED OR REMOVED.

CONTRACTOR TO NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER

SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.

D. CONTRACTOR TO COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL

TRADES PRIOR TO INSTALLATION.

E. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED AT

CONNECTIONS BETWEEN ALL DISSIMILAR METALS.

F. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS REQUIRED TO

COMPLETE THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND

RETURN TO MATCH EXISTING CONDITIONS AND FINISHES.

G. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED EXTERIOR

PIPE PENETRATIONS AND SEAL COMPLETELY.

H. CONTRACTOR TO PROVIDE TEMPORARY FLOORING WHILE MODIFYING

SUBFLOORING.

I. ANY LANDSCAPE, HARDSCAPE, FIXTURE, SIGNAGE AND SYSTEMS OR

PEDESTRIAN CONTROL DEVICES WITHIN THE TEMPORARY ACCESSIBLE

PATHWAY SHALL BE PROTECTED IN PLACE OR TEMPORARILY RELOCATED AS

NECESSARY FOR CONTINUED UNINTERRUPTED OPERATION, ACCESS,

MAINTENANCE AND / OR VISIBILITY.

J. NEW PHARMACY FIRST FLOOR STRUCTURAL SLAB IS SET TO BE 12'-0" IN

ARCHITECTURAL DRAWINGS, THIS IS INTENDED TO BE EQUAL TO CIVIL FF=110.88'

MEASUREMENT. REFER TO CIVIL SHEET CG101 FOR ADDITIONAL ELEVATION

INFORMATION. THESE MEASUREMENTS ARE INTENDED TO ALIGN TO EXISTING

1ST FLOOR WALKWAY SLAB, VIF FINAL CONNECTION ALIGNMENT.

INTERIOR STUD FRAMED WALL. SEE WALL TYPES

AREA NOT IN CONTRACT, FACILITY TO REMAIN

OPERATIONAL

PROPOSED EXTERIOR WALL. SEE WALL SECTIONS

1 HR FIRE AND SMOKE BARRIER

2 HR FIRE AND SMOKE BARRIER

SMOKE RATED PARTITION / SMOKE BARRIER /

COMPARTMENT

1 HR FIRE RATED PARTITION

2 HR FIRE RATED PARTITION

FURNITURE, FIXTURE, & EQUIPMENT INDICATORA1000

EXISTING GRID / NEW GRID

EXISTING DOOR TO REMAIN /

NEW DOOR AND DOOR TAG

MATCHLINE

#-X #-N

XX

WALL TAG - SEE SHEET A-720 FOR ADDITIONAL INFO

XX WINDOW TAG

NEW BUILDING EXPANSION JOINT

DEDUCTIVE ALTERNATE

F1

A-301

UTILITY TUNNEL

3' - 0"

PRECAST CONCRETE HOLLOW

CORE SLAB

2" CONCRETE TOPPING

RIGID MINERAL FIBERBOARD

INSULATION

WATERPROOFING

DRAINAGE MAT

2" 8"

8' -2

10" 8'-8 5/8"

10"

1 - 2" WASHED ROCK DRAINAGE

FILTER FABRIC

4" PERFORATED PVC PIPE

FOUNDATION DRAIN

UTILITIES - SEE MEP AND CIVIL

PLANS FOR ADDITIONAL

INFORMATION

CAST-IN-PLACE CONCRETE

WALLS - SEE STRUCTURAL

CAST-IN-PLACE CONCRETE

SLAB - SEE STRUCTURAL

CONCRETE FOOTING - SEE STRUCTURAL

FLOOR 1

12' - 0"

UTILITY TUNNEL

3' - 0"

PRECAST CONCRETE HOLLOW

CORE SLAB

2" TOPPER

CAST-IN-PLACE CONCRETE WALL

3'-0" X 5'-0" HOLLOW METAL

FRAME AND LOUVERED DOOR

6' -8

DOOR SWING FOR REFERENCE

STEEL ACCESS LADDER ON

WALL BEHIND, RUNGS @ 12"

O.C. VERTICALLY, SEE DETAIL F1

AND E1 ON SHEET A-422

STEEL PLATE GRATING WELL COVER -

WELDED TO STEEL ANGLES

STEEL ANGLE LEDGES

36" X 36" STEEL PLATE GRATE ACCESS

HATCH W/ PADLOCK CONNECTION

FACE OF BUILDING BEYOND

SLOPED TOPPING POUR

PROVIDING DRAINAGE IN

WELL AND TUNNEL, TYP,

SEE PLAN.

2' -0

8" 6'

-0

RIGID MINERAL FIBERBOARD

INSULATION

DRAINAGE MAT

1 - 2" WASHED ROCK DRAINAGE

4" PERFORATED PVC PIPE

FOUNDATION DRAIN

1/8" / 1'-0" 1/8" / 1'-0"

7' -2

N

B1 KEY PLAN

EXISTING

PHARM

B1

B2

AREA

A

AREA

B

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - THE A&E GROUP

100 Pearl Street, 14th Floor

Hartford, CT, 06103

860-270-0753

Mat Perkins

B

IM

/6

-1

-4

C o n s tr u c t N e w

I n p a ti e n t P h a rm a c y /6

-1

-4

.0 .A

R C

H .A

B l o c a ti o n .r v t

/9

/2

:1

:3

P M

A-100

ARCHITECTURAL UTILITY TUNNEL PLAN &

DETAILS

689-411

B1

07/18/2024 MRP CJL

ISSUED FOR BIDDING CONSTRUCT NEW

INPATIENT PHARMACY

950 CAMPBELL AVENUE WEST HAVEN, CT 06516

1/8" = 1'-0" D3

00-UTILITY TUNNEL

3/4" = 1'-0" F6

UTILITY TUNNEL SECTION

3/4" = 1'-0"

F3

UTILITY TUNNEL ACCESS WELL SECTION

1 CEILING MOUNTED STEAM PIPING - SEE MECHANICAL AND PLUMBING DRAWINGS

FOR ADDITIONAL INFORMATION.

2 ACCESS WELL - SLOPE FLOOR TO DRAIN

3 FLOOR DRAIN, SEE PLUMBING

4 FOUNDATION DRAINAGE, CONNECTS TO STORM, SEE CIVIL

5 FOUNDATION JOINT, FILL GAP BETWEEN EXISTING AND NEW WITH GRANULAR FILL

6 PNUEMATIC TUBE SYSTEM ROUTED THROUGH EXISTING EXTERIOR WALL

7 WELL IN UTILITY TUNNEL TO PERMIT MAINTENANCE ACCESS TO VERTICAL

TRANSITION OF STEAM LINES FROM SUB-BASEMENT. PROVIDE LADDER AND

FALL-PROTECTION VIA REMOVABLE STEEL GRATE. COORDINATE FINAL SIZE WITH

REQUIRED ACCESS CLEARANCE

8 EXISTING AREAWAY TO BE RETAINED

9 ELECTRICAL MANHOLE BELOW GRADE, SHOWN FOR REFERENCE ONLY, SEE CIVIL,

SEE ELECTRICAL SHEET E502.

10 WALL MOUNTED PREMANUFACTURED LADDER

DN

1X 5X 6X

M-X

P-X

Q-X

R-X

S

T

U

Y

Y'

Z

Z'

BB

CC'

EE

EE'

FF

GG

HH

P'-X

V

AA

CC

DD

2X 3X 4X

W'

X

W

A-201

D2

B

B

E

E

G

G

H

H

K

K

M

M

C

C

3' -8

'-0

8' -0

'-6

'-9

3'

-9

'-5

'-7

/2

J

J

TECHNOLOGY

12511251

CORRIDOR

12891289

RECEIVING &

INVENTORY

1255A1255A

HAC

12811281

STORAGE,

ACTIVE

12761276

CORRIDOR

12901290

HAZARD

STORAGE

1255B1255B

UNI

RESTROOM

12851285

UNI

RESTROOM

12861286

STAT

COUNTER

12751275

WORKSTATION

1256B1256B

HAZARD

DRUG

STORAGE

12661266

STERILE

HAZARD

DRUG

BUFFER

12651265

ANTE/

DECONTAMINATION

12631263

STERILE

NON-HAZARD

DRUG

BUFFER

12621262

HAC

CABINETS

1263A1263A

NON-STERILE

COMPOUNDING

1261A1261A

WORKSTATION

1256A1256A

REVERSE

DISTRBUTION/

SEGREGATED

DRUG STRG.

12721272

HALL

12871287

LIQUID/COMPLEX

REPACKAGING

12611261

REFRIG

12791279

FILLING,

ASSEMBLY &

SIMPLE

REPACKAGING

12741274

TECH

PROCESSING

12701270

RESTOCK

AND CRASH

CARTS

12671267

TECH

PROCESSING

12691269

STAFF

LOCKERS

1287A1287A

PNEUMATIC

TUBE

STATION

12711271

CORRIDOR

12561256

SECURED

DISPENSING

1276A1276A

CONTROLLED

SUBSTANCES

VAULT

1276B1276B

IV

ADMIXTURE

REFRIGERATION

12681268

STERILE

FLUIDS &

STORAGE

12551255

SUPERVISOR

OFFICES

12601260

EAST STAIR

12951295

TECH

OFFICES

12581258

PURCHASING

OFFICE

12571257

STERILE

COMPOUNDING

SUPPLIES

12641264

LOGISTICS/

ADD. STERILE

STRG

12521252

REFRIGERATION

12781278

DRUG

INFORMATION/

DISCHARGE

12731273

WORKSTATION,

PHARMACIST

12771277

CLINICAL

DIRECTOR

OFFICE

12591259

ELECTRICAL

12541254

CONFERENCE

ROOM

12841284

FUTURE

WEST STAIR

12961296

1255A

1276A

A

CORRIDOR

12891289

F

F

D

D

19'-0" 3'-0" 13'-9" 8'-3" 16'-5" 4'-0" 23'-7" 22'-6" 9'-4"

13'-4" 47'-7 7/8" 75'-3 3/4" 9'-0 3/4" ±

13'-4" TO F.O. MASONRY

1'-4 5/8" TO GRID

22'-0" 22'-0"

1'-4 3/4" TO F.O. MASONRY

42'-7 1/4" 22'-6" 9'-4"

1'-3 3/4"

3'-6" FROM F.O. MASONRY

7'-4" M.O. 6'-0" 7'-4" M.O. 6'-0" 7'-4" M.O. 6'-0" 7'-4" M.O. 16'-7 1/4" 8'-3 3/4"

9'-4 1/4"

'-0

'-6

/2

'-1

0"

2'-4" 7'-4" 3'-8"

13'-2" 19'-0" 3'-0" 13'-9" 8'-3" 20'-5" 23'-7" 22'-6" 9'-4" 15'-4" 8'-0"

2'-4" 7'-4" M.O. 3'-8 5/8" 11'-4" 7'-4" 9'-4" 7'-4" 11'-3" 6'-4" 7'-4" 13'-7" 7'-4" 15'-8" 7'-4" 8'-10" 7'-4"

10" TO F.O. MASONRY

8' -1

1/

2" S

T A

IR

'-4

/2

O V

E R

A

LL

134'-6 3/4" OVERALL 23'-9 1/4" STAIR OVERALL

47'-1" 74'-1" 23'-4"

4" EXP JT

5 1/4" 2'-2" M.O.

3'-10"

17'-4"

4" EXP JT

A-201

B2

A-201

F1

A-201

F5

F1

A-301

B1

A-302 B5

A-302

F1

A-302

5 6

TYP.

TYP.

TYP.

F

IE

LD

V

A R

IF

Y

3' -2

/4

F

IE

LD

V E

R

IF

Y

- 3 1'

-9

F1

A-351

F4

A-352

E6

A-351

E7

A-351F8

A-352

F6

A-352

A

A

1' -0

/8

5/

8"

8' -0

1'-0" 1'-0"

1' -4

O

F S

LA

B

1' -4

T

O E

D G

E

4' -1

0"

'-1 1"

8' -3

4"

'-0

F1

A-352

8'-1"

8'-1"

8'-1"

F6

A-352

SIM

F6

A-352

SIM

F6

A-352

SIM

M A

T C

H

LI

N E

E : F

4/ A

-1

B

M A

T C

H

LI

E : F

1/ A

-1

A

22'-4"

EXISTING

CORRIDOR

VESTIBULE

12881288

13'-2"

OF SLAB

1'-3" TO EDGE

F.8 L

L

2 2 2 2

1 111

A-501

F7

58 SF

STAT

COUNTER

PATIENT SIDE

'-4

/4

FEC

FEC

FEC

FEC

E6

A-351

SIM

E6

A-351

SIM

O F

S

LA

B 1'

-8

T O

E D

G E

OF SLAB

1'-4" TO EDGE

OF SLAB

1'-4 5/8" TO EDGE

OF SLAB

1'-4 3/4" TO EDGE

OF SLAB

1'-10 3/4" TO EDGE

OF SLAB

1'-6 5/8" TO EDGE

1'-6 5/8"

1' -0

A-421

F1

1288A

F1

A-510

E6

A-351

SIME6

A-351

SIM

DEDUCT ALT.#2

DEDUCT ALT.#3

DEDUCT ALT.#4

A

A

B

1295B

STAFF

LOUNGE

12831283

A

1295C

4' -4

'-8

M .O

'-2

/4

'-8

M

.O

2' -8

/4

2'-0" 2'

-4

12'-0 1/4"12'-0"

11'-2 7/8"

10'-0"

UP

10'-0"

A-201

D1

'-0

O F

S

LA

B 1'

-4

T O

E D

G E

'-1

1/

4"

VIF

15'-4" 8'-0" 4"

O F

S

LA

B 1'

-8

T O

E D

G E

O F

S

LA

B

5/ 8"

T O

E D

G E

O F

S

LA

B 1'

-9

T O

E D

G E

SUPERVISOR

11821182

SURGICAL

ANATOMIC

PATHOLOGY

11801180

CORRIDOR

1C8-011C8-01

L56 concrete on grade 5"

ARCHITECTURAL SYMBOL LEGEND

GENERAL SHEET NOTES

KEYNOTES

KEY PLAN

A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE RATED

WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA. PROVIDE ALL

PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT WALLS SHALL BE

CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED

FIRE PROOF CAULKING MATERIAL. SEE MECHANICAL AND PLUMBING DRAWINGS

FOR ADDITIONAL INFORMATION.

B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND CONDUIT PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

C. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION

WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM THOSE INDICATED.

CONTRACTOR TO FIELD VERIFY IN ADVANCE THE LOCATION AND CONDITION OF

THOSE EXISTING SYSTEMS SHOWN TO BE MODIFIED OR REMOVED.

CONTRACTOR TO NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER

SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.

D. CONTRACTOR TO COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL

TRADES PRIOR TO INSTALLATION.

E. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED AT

CONNECTIONS BETWEEN ALL DISSIMILAR METALS.

F. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS REQUIRED TO

COMPLETE THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND

RETURN TO MATCH EXISTING CONDITIONS AND FINISHES.

G. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED EXTERIOR

PIPE PENETRATIONS AND SEAL COMPLETELY.

H. CONTRACTOR TO PROVIDE TEMPORARY FLOORING WHILE MODIFYING

SUBFLOORING.

I. ANY LANDSCAPE, HARDSCAPE, FIXTURE, SIGNAGE AND SYSTEMS OR

PEDESTRIAN CONTROL DEVICES WITHIN THE TEMPORARY ACCESSIBLE

PATHWAY SHALL BE PROTECTED IN PLACE OR TEMPORARILY RELOCATED AS

NECESSARY FOR CONTINUED UNINTERRUPTED OPERATION, ACCESS,

MAINTENANCE AND / OR VISIBILITY.

J. NEW PHARMACY FIRST FLOOR STRUCTURAL SLAB IS SET TO BE 12'-0" IN

ARCHITECTURAL DRAWINGS, THIS IS INTENDED TO BE EQUAL TO CIVIL FF=110.88'

MEASUREMENT. REFER TO CIVIL SHEET CG101 FOR ADDITIONAL ELEVATION

INFORMATION. THESE MEASUREMENTS ARE INTENDED TO ALIGN TO EXISTING

1ST FLOOR WALKWAY SLAB, VIF FINAL CONNECTION ALIGNMENT.

INTERIOR STUD FRAMED WALL. SEE WALL TYPES

AREA NOT IN CONTRACT, FACILITY TO REMAIN

OPERATIONAL

PROPOSED EXTERIOR WALL. SEE WALL SECTIONS

1 HR FIRE AND SMOKE BARRIER

2 HR FIRE AND SMOKE BARRIER

SMOKE RATED PARTITION / SMOKE BARRIER /

COMPARTMENT

1 HR FIRE RATED PARTITION

2 HR FIRE RATED PARTITION

FURNITURE, FIXTURE, & EQUIPMENT INDICATORA1000

EXISTING GRID / NEW GRID

EXISTING DOOR TO REMAIN /

NEW DOOR AND DOOR TAG

MATCHLINE

#-X #-N

XX

WALL TAG - SEE SHEET A-720 FOR ADDITIONAL INFO

XX WINDOW TAG

NEW BUILDING EXPANSION JOINT

DEDUCTIVE ALTERNATE

N

B1 KEY PLAN

EXISTING

PHARM

B1

B2

AREA

A

AREA

B

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - THE A&E GROUP

100 Pearl Street, 14th Floor

Hartford, CT, 06103

860-270-0753

Mat Perkins

B

IM

/6

-1

-4

C o n s tr u c t N e w

I n p a ti e n t P h a rm a c y /6

-1

-4

.0 .A

R C

H .A

B l o c a ti o n .r v t

/9

/2

:1

:4

P M

A-101

ARCHITECTURAL FLOOR PLAN - FIRST FLOOR -

OVERALL

689-411

B1

07/18/2024 M. PERKINS K. BICKEL

ISSUED FOR BIDDING CONSTRUCT NEW

INPATIENT PHARMACY

950 CAMPBELL AVENUE WEST HAVEN, CT 06516

1/8" = 1'-0" F1

ARCHITECTURAL FLOOR PLAN - FIRST FLOOR - OVERALL

1 EAST WEST POINT OF ORIGIN FOR DIMENSIONS AT WEST FACE OF EXISTING

BUILDING. NORTH SOUTH POINT OF ORIGIN AT CORNER OF BRICK WALL.

2 4" EXPANSION JOINT BETWEEN NEW AND EXISTING CONSTRUCTION, TYP.

3 SLOPE FLOOR TO DRAIN

4 WINDOWS WITH # 304 STAINLESS STEEL WOVEN SECURITY MESH SECURELY

ANCHORED TO INTERIOR WINDOW FRAME AND INTRUSION DETECTION ALARM THAT

ANNUNCIATES IN THE SECURITY CONTROL CENTER

5 DOOR AND LOCK STATUS SENSORS AND MOTION SENSORS IN PHARMACY

6 PHARMACY ENTRIES AND NARCOTIC VAULTS MUST BE CONTROLLED VIA CARD

READERS

7 CCTV MUST BE USED AT ENTRY POINTS, EXIT POINTS SERVICE INTERACTION AREA

AND WINDOWS AND WAITING AREAS

8 WALK-IN REFRIGERATION / FREEZER ASSEMBLY WITH DOOR. FRAME WALL AROUND

UNIT TO ENCLOSE.

9 SECURITY AND BULLET RESISTANT WALL & WINDOW SYSTEM AND PASS THRU AT

STAT COUNTER (UL 752 LEVEL 3 BALLISTIC CONSTRUCTION AND 15 MINUTE FORCED

ENTRY RESISTANT)

10 ALL VENTS, DUCTS, AND SIMILAR OPENINGS IN EXCESS OF 96 SQUARE INCHES THAT

PASS THROUGH A PERIMETER PARTITION SHALL BE PROTECTED WITH BARS OR

GRILLS OF 1/2" DIAM STEEL WELDED VERTICALLY AND HORIZONTALLY 6" ON CENTER

OR GRILLS OF 9 GAUGE EXPANDED STEEL

11 SITE PAVING, SEE CIVIL FOR MORE INFORMATION

12 NEW MECHANICAL EQUIPMENT, REFER TO MECHANICAL PLANS.

13 EXISTING RAILING, DUCTWORK AND AREAWAYS TO REMAIN, PROTECT IN PLACE

14 UTILITY TUNNEL ACCESS WELL - SEE A-100.

15 FLOOR SINK.

16 DRINKING FOUNTAIN

17 NEW ACCESS GATE TO CONNECT TO AREAWAY EXISTING GUARDRAIL.

18 WALK-OFF GRATE IN SLAB DEPRESSION, PROVIDE DRAINAGE AWAY FROM DOOR

19 COLUMN SURROUND TO MEET UL BXUV.X528 SYSTEM(DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED)

DEDUCT ALTERNATE #1: REMOVE EXTERIOR THIN CONCRETE AND METAL

PANEL SYSTEM; CHANGE TO EIFS SYSTEM ON EXTERIOR ENVELOPE SYSTEM.

DEDUCT ALTERNATE #2: ELIMINATE 280 S.F. OF STORAGE SPACE

DEDUCT ALTERNATE #3: ELIMINATE THE CONFERENCE ROOM, STAFF LOCKER

ROOM AND STAFF LOUNGE, 600 S.F

DEDUCT ALTERNATE #4: ELIMINATE 425 S.F. OF OFFICE SPACE

DEDUCTIVE ALTERNATES: SHOWN ON THIS SHEET #2, #3,#4

EQUAL TO CIVIL

FF=110.88'

EQUAL TO CIVIL

FF=110.88'

EQUAL TO CIVIL

108.51'

DN

B E G

C

TECHNOLOGY

ACTUAL: 116 SF

PROG: 30 SF

CORRIDOR

ACTUAL: 1231 SF

PROG: 0 SF

HAC

ACTUAL: 46 SF

PROG: 60 SF

UNI

RESTROOM

ACTUAL: 59 SF

PROG: 60 SF

UNI

RESTROOM

ACTUAL: 60 SF

PROG: 60 SF

STAT

COUNTER

ACTUAL: 44 SF

PROG: 65 SF

WORKSTATION

1256B

ACTUAL: 49 SF

PROG: 60 SF

HAZARD

DRUG

STORAGE

ACTUAL: 151 SF

PROG: 150 SF

55 5 5

STERILE

HAZARD

DRUG

BUFFER

ACTUAL: 249 SF

PROG: 250 SF

ANTE/

DECONTAMINATION

ACTUAL: 171 SF

PROG: 120 SF

STERILE

NON-HAZARD

DRUG

BUFFER

ACTUAL: 251 SF

PROG: 250 SF

HAC

CABINETS

1263A

ACTUAL: 28 SF

PROG: 15 SF

NON-STERILE

COMPOUNDING

1261A

ACTUAL: 43 SF

PROG: 40 SF

WORKSTATION

1256A

ACTUAL: 44 SF

PROG: 60 SF

REVERSE

DISTRBUTION/

SEGREGATED

DRUG

STRG.

ACTUAL: 63 SF

PROG: 0 SF

HALL

ACTUAL: 218 SF

PROG: 0 SF

LIQUID/COMPLEX

REPACKAGING

ACTUAL: 220 SF

PROG: 250 SF

FILLING,

ASSEMBLY

& SIMPLE

REPACKAGING

ACTUAL…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .