This document is a solicitation for a firm-fixed-price contract to construct a new inpatient pharmacy at the Department of Veterans Affairs (VA) West Haven Medical Center in West Haven, CT. The project involves constructing a two-story, 10,500 square foot addition to Building 1 that will house the new inpatient pharmacy on the first floor and mechanical space on the second floor. The work includes general construction, alterations, demolition, and removal of asbestos-containing materials and lead-based paint. The solicitation will be issued as an Invitation for Bid (IFB) under a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside, with an expected contract value between $20-50 million. The period of performance is approximately 730 calendar days from the Notice to Proceed. All questions must be submitted in writing to the VA Technology Acquisition Center Austin.
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
ARCHITECTURAL SYMBOLS
SHEET NUMBER
A-100 Sheet Number
Discipline Code
A-1 1/8" = 1'-0"
View Name
VIEW TITLE
Drawing Scale
Drawing Number
1/8" = 1'-0"
View NameA-1 A101R101
VIEW TITLE WITH REFERENCES
Drawing Scale
Sheet Number
Drawing Number
Reference Sheet Number
EXTERIOR ELEVATIONS
INTERIOR ELEVATIONS
A-200
A1 Position on Sheet
Sheet Number
Position on Sheet
Sheet Number
A1
A2B2
B1
A-350
MATCH LINES
MATCHLINE
SEE: A1/A-101B
Sheet Number
Position on Sheet
AREA REFERENCE
A
SEE: (X/X-XXX)
Reference to Area
View Reference for Additional Information
BUILDING SECTION
Position on Sheet
Sheet Number
SIM
X
X-XXX
SIM
X
X-XXX
WALL SECTION
Position on Sheet
Sheet Number
X
X-XXX
SIM
DETAIL - SECTION
SIM
X
X-XXX
Position on Sheet
Sheet Number
DETAIL - PLAN/RCP
SIM
X
X-XXX
Position on Sheet
Sheet Number
DRAWING REVISIONS
Revision Number
NORTH ARROW
True North
PLAN
NORTH
NORTH
TRUE
Plan North
0 4'-0" 8'-0" 16'-0"
IF THIS IS NOT A 42"x30" SHEET IT IS A
REDUCED SIZE PLOT, USE GRAPHIC
SCALE ACCORDINGLY.
GRAPHIC SCALE
COLUMN GRID LINES
Column Grid Line (New)
Column Grid Line (Existing)
1 2
A
B
LEVEL DATUM
LEVEL XX
0' - 0"
Level Name
Level Elevation
SPOT ELEVATION
0'-0"
Spot Elevation
ROOM TAG
ROOM
NAME
ABC123
150 SF
Room Name
Room Number
CEILING TAG
Type Mark
1' - 0" AFF
Ceiling Type
Ceiling Height
DOOR NUMBER TAG
New Door Door Number Tag
1A
Existing Door Door Number Tag
1A101
WINDOW TAG
Interior Window Tag
XX
XX
Exterior Window Tag
CURTAIN WALL TAG
XX
Interior Curtain Wall Tag
Exterior Curtain Wall Tag
XX
AD100
Room Code Room Area Or Volume
1T
CURTAIN PANEL TAG
Interior Curtain Wall Tag
WALL TYPE TAG
≠ A# B
C
V V ITEM -
VA Supplied & Installed
V C ITEM -
VA Supplied & Contractor Installed
C C ITEM -
Contractor Supplied & Installed
FFE Tag (By JSN)A1000
FEC FFE Tag Furnished By VA Equipment Vendor
? KEYNOTE
1"
R 1/2"
90°
DIMENSION TO FACE OF
FINISH, FACE OF CONCRETE,
COLUMN CENTERLINE, OR AS
NOTED.
DIMENSIONS
1"
Symbol Indicates No Sound
Attenuation
Partition Type
CMU/Stud Width
Partition Modifier Partition Modifier II
KEYNOTE TAG
SEE A-720 STANDARD PARTITION TYPES
Contract Limit line Style
Not In Contract Area
CONTRACT LIMIT GRAPHIC
LINE STYLES
Centerline
Demolished
Temporary
Hidden
Overhead
Matchline
FURNITURE, FIXTURE, & EQUIPMENT
8'-6"1
Name
Room Name Room Number
Existing Finish Key
Ceiling Height
FEC Toilet Accessory Tag. See A-730
Deduct alt
MATERIALS LEGEND
CONCRETE (SECTION)
GRANULAR FILL
CONCRETE MASONRY UNITS
BRICK
RIGID INSULATION (SECTION)
ACOUSTIC/THERMAL INSULATION (SECTION)
STEEL (SECTION)
ALUMINUM (SECTION)
WOOD FINISH (SECTION)
LUMBER FINISH (SECTION)
EARTHWORK (SECTION)
STUD WALL (PLAN & SECTION)
EXISTING WALL TO REMAIN (PLAN & SECTION)
DEMOLISHED WALL (PLAN &
SECTION)
EXISTING TO REMAIN
EXISTING TO BE REMOVED
EXISTING TO REMAIN
NEW CONSTRUCTION
DOOR NUMBER
SYMBOL AND MINIMUM
CLEARANCES
18" MIN.
12" MIN.
6" MIN.
1A
WALL LEGEND
REFLECTED CEILING SYMBOLS
SMOKE DETECTOR
SPEAKER
HVAC RETURN DIFFUSER
EXIT LIGHT
HEAT DETECTOR
HVAC EXHAUST DIFFUSER
LINEAR LUMINAIRE
RECESSED ROUND DOWNLIGHT
LUMINAIRE - INSTALL CENTERED IN
ACOUSTICAL CEILING TILE UNO
RECESSED LUMINAIRE (24x48)
ACOUSTICAL TILE CEILING (24x24)
ACOUSTICAL TILE CEILING (24x48)
GYPSUM BOARD CEILING
ACCESS PANEL
HVAC SUPPLY DIFFUSER
SPRINKLER
SURFACED MOUNTED LUMINAIRE
(12x48)
WALL PACK
SD
INDOOR AC UNIT
SECURITY
CAMERA
FIRE ALARM
STROBE
S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - THE A&E GROUP
100 Pearl Street, 14th Floor
Hartford, CT, 06103
860-270-0753
Mat Perkins
B
IM
/6
-1
-4
C o n s tr u c t N e w
I n p a ti e n t P h a rm a c y /6
-1
-4
.0 .A
R C
H .A
B l o c a ti o n .r v t
/9
/2
:1
:3
P M
A-001
ARCHITECTURAL SYMBOLS, & GENERAL NOTES 689-411
B1
07/18/2024 M. PERKINS S.POLLARD
ISSUED FOR BIDDING CONSTRUCT NEW
INPATIENT PHARMACY
950 CAMPBELL AVENUE WEST HAVEN, CT 06516
ABBREVIATIONS
° DEGREE
± PLUS/MINUS
⌀ DIAMETER
≈ ALMOST EQUAL
∠ ANGLE
℄ CENTER LINE
Δ DELTA, DEFLECTION
ϕ ELECTRICAL PHASE
≠ NOT EQUAL
Ω OHM, OMEGA
BOUNDARY LINE
FLOW LINE
≡ IDENTITY
INITIAL LENGTH
MOMENT LINE
PROPERTY LINE, PLATE
½ ONE HALF FRACTION
¼ ONE QUARTER FRACTION
¾ THREE QUARTERS FRACTION
> GREATER THAN
≥ GREATER THAN OR EQUAL TO
< LESS THAN
≤ LESS THAN OR EQUAL TO
ABCDEFGHIJKMNOPQRSTUVWXYZ 1234567890
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AAMA AMERICAN ARCHITECTURAL
MANUFACTURERS ASSOCIATION
AB ANCHOR BOLT, AUGER BORING
ABA ARCHITECTURAL BARRIERS ACT
ABC AGGREGATE BASE COURSE
ABS AIR BREAK SWITCH
AC ASBESTOS CEMENT OR ASPHALTIC
CONCRETE, ACCESS CONTROL DEVICE
ACB AIR CIRCUIT BREAKER
ACI AMERICAN CONCRETE INSTITUTE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACSR ALUMINUM CONDUCTOR STEEL
REINFORCED
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
ADO AUTOMATIC DOOR OPERATOR
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGA AMERICAN GAS ASSOCIATION
AGC ASSOCIATED GENERAL CONTRACTORS
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
AL ALUMINUM
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AM ACOUSTIC MATERIAL
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
ANT ANTENNA
AP ACCESS PANEL, APPROX.,
APPROXIMATE
APA AMERICAN PLYWOOD ASSOCIATION
APPD APPROVED
APPROX APPROXIMATE
APT APARTMENT
AR AS REQUIRED
ARR ARRESTOR
ARCH ARCHITECT, ARCHITECTURAL
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL
INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALS
ATCH ATTACHMENT
ATM AUTOMATIC TELLER MACHINE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING
INSTITUTE
AWPA AMERICAN WOOD PRESERVERS'
ASSOCIATION
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
B BASELINE, BOTTOM
B LABEL CLASS B DOOR
B PL BASE PLATE
BALC BALCONY
BAT BATTEN
BB BULLETIN BOARD
BD BOARD
BD FT BOARD FEET (FOOT)
BEJ BRICK EXPANSION JOINT
BEV BEVEL
BHMA BUILDER'S HARDWARE
MANUFACTURER'S ASSOCIATION
BI FLD DR BIFOLDING DOORS
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
BLDG BUILDING
BLKT BLANKET
BLVD BOULEVARD
BM BEAM OR BENCHMARK
BO BOARD
BOT BOTTOM
BR BEDROOM, BOTTOM REGISTER
BRCG BRACING
BRDG BRIDGING
BRDG JST BRIDGING JOIST
BRG BEARING
BRG PL BEARING PLATE
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BU BUSHEL
BUR BUILT-UP ROOFING
C CELSIUS, CHANNEL
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
C TO C CENTER TO CENTER
CAB CABINET
CAC CEILING ATTENUATION CLASS
CB CATCH BASIN, CORNER BEAD, CIRCUIT
BREAKER
CBB CEMENTITIOUS (BACKER) BOARD
CC CUBIC CENTIMETER, CONTRACTOR
SUPPLIED & INSTALLED
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTERCLOCKWISE
CD CONSTRUCTION DOCUMENTS,
CONTRACT DOCUMENTS, CEILING
DIFFUSER
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED /
CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER
INSTALLED
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CENTER OF GRAVITY, CORNER GUARD
C&G CURB AND GUTTER
CGSFU CERAMIC GLAZED STRUCTURAL
FACING UNITS
CH CHILLER
CH BD CHALKBOARD
CHEM CHEMICAL
CHFR CHAMFER
CHK CHECK
CI CAST IRON
CIP CAST-IN-PLACE
CIR CIRCLE
CIRC CIRCULAR
CJ CONSTRUCTION JOINT OR CONTROL
JOINT
CL CENTER LINE
CLDG CLADDING
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CM² SQUARE CENTIMETER
CM³ CUBIC CENTIMETER
CM CONSTRUCTION MANAGEMENT
CMP CORRUGATED METAL PIPE
CMPA CORRUGATED METAL PIPE ARCH
CMU CONCRETE MASONRY UNIT
CND CONDUIT
CNDS CONDENSATE
CNR CORNER
CNTR COUNTER
CO CARBON MONOXIDE, CERTIFICATE OF
OCCUPANCY, CLEANOUT, OR COMPANY
CO2 CARBON DIOXIDE
CODP CLEANOUT W/ DECK PLUG
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
CONC FLR CONCRETE FLOOR
COND CONDENSER OR CONDITION
CONF CONFERENCE
CONN CONNECT, CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR, CONTRACTION
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CORR CORRIDOR
CP NON-REINFORCED CONCRETE PIPE
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CPT CARPET
CR CHAIR, CRASH RAIL
CRS COLD ROLLED STEEL
CRSI CONCRETE REINFORCING STEEL
INSTITUTE
CS CONCRETE SEALER/SURFACE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSI CONSTRUCTION SPECIFICATIONS
INSTITUTE
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE, CURRENT
TRANSFORMER, COOLING TOWER
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER, CONTOUR, COOLING TOWER
RETURN
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER C
CUH CABINET UNIT HEATER
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CURT CURTAIN
CW COLD WATER
CWB CAPILLARY WATER BARRIER
CWR COLD WATER RETURN
CYL CYLINDER
CYL L CYLINDER LOCK
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL, DRY BUILT, DIRECT BURIAL
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DD DIVERSION DIKE
DEG, ° DEGREE
DEL DELETE
DEMO DEMOLITION
DEML DELAYED EGRESS MAGNETIC LOCK
DEPH DELAYED EGRESS PANIC EXIT DEVICE
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DI DUCTILE IRON
DIA, DIAMETER
DIAG DIAGONAL DIAGRAM
DIAG DIAGRAM DIAGONAL
DIFF DIFFERENCE OR DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DMPR DAMPER
DN DOWN
DP DISTRIBUTION
DPS DOOR POSITION SWITCH
DOC DOCUMENT
DOUG FIR DOUGLAS FIR
DOZ DOZEN
DR DOOR, DRAIN, DRESSING ROOM, OR
DRIVE
DR CL DOOR CLOSER
DR FR DOOR FRAME
DR OPNG DOOR OPENING
DS DOWNSPOUT, STORM DRAINAGE
STRUCTURE
DSGN DESIGN
DW DISHWASHER, DOMESTIC WATER
DWD DRINKING WATER DISPENSER
DWG DRAWING
DWTR DUMBWAITER
E EAST
E LABEL CLASS E DOOR
EA EACH
EAM EXCEPT AS NOTED
EAT ENTERING AIR TEMPERATURE
EF EACH FACE, EXHAUST FAN
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EG EXHAUST GRILLE
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
EL ELEVATION, ELECTRIC LOCK OR
ELECTRIC LEVER EXIT DEVICE
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEC DR OP ELECTRIC DOOR OPENER
ELEV ELEVATOR
ELR ELECTRIC LATCH RETRACTION EXIT
DEVICE
EMCH ELECTRO-MECHANICAL CLOSER-HOLDER
EMER EMERGENCY
EMER SHR EMERGENCY SHOWER
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
E/P EDGE OF PAVEMEMNT
EPA ENVIRONMENTAL PROTECTION
AGENCY
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ER EXHAUST REGISTER
ERD EXISTING ROOF DRAIN
ES ELECTRIC STRIKE
ESC ESCAPE OR ESCUTCHEON
ESCAL ESCALATOR
ESMT EASEMENT
ESP ESPECIALLY
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
EVAP EVAPORATIVE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXP BT EXPANSION BOLT
EXP JT EXPANSION JOINT
EXST GR EXISTING GRADE
EXT EXTERIOR, EXTERNAL, OR
EXTINGUISHER
EXT GR EXTERIOR GRADE
F FAHRENHEIT, FEMALE, FIRE, FUSE,
FILTER
FA FIRE ALARM
FAB FABRIC
FABX FIRE ALARM BOX
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN, FIRE DAMPER
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF&E, FFE FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD, FLAT HEAD SCREWS, FIRE
HYDRANT
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIG FIGURE
FIL FILLET
FIN FINISH
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIN WD FINISH WOOD
FIXT FIXTURE
FJ FELT JOINT
FL FLOORLINE, FLOOR, FLASHING, FLOW
LINE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR FLOOR
FLR FIN FLOOR FINISH
FLR SK FLOOR SINK
FLUOR FLUORESCENT
FLUOR FIX FLUORESCENT FIXTURE
FM FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
4 WAY FOUR WAY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPH FROST PROOF HYDRANT
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR
FRAME
FR SNK FLUSHING RIM SINK
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR
FIBERGLASS REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION, FULL SIZE,
FAIL SAFE
FSE FAIL SECURE
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH OR FURNITURE
FUT FUTURE
FW FIRE WATER
FWC FABRIC WALLCOVERING
G GROUND, GAS LINE, GRAM
GA GAGE OR GYPSUM ASSOCIATION
GAL GALLON, GALVANIZED
GALV GALVANIC OR GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR, GLAZED
COATING
GD GUARD
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GFI GROUND FAULT INTERRUPT
GFMU GROUND FACE MASONRY UNIT
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTIC
GI GALVANIZED IRON
GL GLASS
GLZ-C GLAZED BLOCK-CMU
GLZ-T GLAZED BLOCK-CLAY TILE
GL BLK GLASS BLOCK
GLU LAM GLUED LAMINATED WOOD
GR GRADE
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GW GROUND WATER
GWB GYPUSM WALL BOARD
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H HIGH, HEIGHT, HUMIDIFIER
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAC HOUSEKEEPING AIDS CLOSET
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE, HANDICAPPED
HCWD HOLLOW CORE WOOD DOOR
HD HARD DRAWN
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR
(FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HGSW HORN GAP SWITCH
HID HIGH INTENSITY DISCHARGE
HM HECTOMETER
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH PRESSURE, HIGH POINT,
HORSEPOWER
HPS HIGH PRESSURE SODIUM
HQ HEADQUARTERS
HR HOUR
HS HEAT-STRENGTHENED (GLASS) OR
HIGH STRENGTH
HSE HOUSE
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR
CONDITIONING
HVY HEAVY
HW HOT WATER, HEAD WALL
HYD HYDRANT
HYDR HYDRAULIC
HZ HERTZ
I INTERSTATE (HIGHWAY) OR MOMENT
OF INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER, OR
INTERIOR DESIGN
ID NO IDENTIFICATION NUMBER
IE INVERT ELEVATION
ILLUM ILLUMINATION
IMC INTERMEDIATE METAL CONDUIT
INCL INCLUDED
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
INV INVERT
IP INLET PROTECTION
IRBF INDUSTRIAL RESIN BASE FLOORING
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
J-BOX, JB JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JT JOINT
JST JOIST
K KILO
KCP KEENE'S CEMENT PLASTER
KD KILN DRIED OR KNOCKED DOWN
KG KILOGRAM
KN KILONEWTON
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
KV KILOVOLT
KVA KILOVOLT-AMPERE
KW KILOWATT
L ANGLE, LOUVER, LENGTH, LENGTH OF
CURVE
LA LIGHTING ARRESTOR
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LC LEAD COVERED
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE
LHR LEFT HAND REVERSE, LATENT HEAT
RATIO
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED, LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
L/S LITERS PER SECOND
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVC LENGTH OF VERTICAL CURVE
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
M METER, MEGA
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MAS MASONRY
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD METAL DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL, MEDIUM
MEK METHYL ETHYL KETONE
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MHO MAGNETIC HOLD OPEN
MIC MICROPHONE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE
MIN MINUTE MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLO MAIN LUG ONLY
MLWK MILLWORK
mm MILLIMETER
MMP MEMBRANE WATERPROOFING
MO MASONRY OPENING OR MOTOR
OPERATED
MOD MODEL, MODIFY OR MODULE
MOD BIT MODIFIED BITUMEN
MON MONITOR
MOPR MOP RACK
MP MEDIUM PRESSURE
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
M/S METERS PER SECOND
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
N NORTH
NA NOT APPLICABLE
NAAMM NATIONAL ASSOCIATION OF
ARCHITECTURAL METAL
MANUFACTURERS
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA, NON-CORROSIVE
NCOMBL NONCOMBUSTIBLE
NDC NOSE DOWN CURB
NE NORTHEAST
NEC NATIONAL ELECTRICAL CODE
NEG NEGATIVE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NEUT NEUTRAL
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPS NOMINAL PIPE SIZE
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRCA NATIONAL ROOFING CONTRACTORS
ASSOCIATION
NRP NON-REMOVABLE
NS NARROW STILE
NTS NOT TO SCALE
NUM NUMERAL
NW NORTHWEST
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCB OIL CIRCUIT BREAKER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER OUTSIDE
DIMENSION
OD OUTSIDE DIMENSION OUTSIDE
DIAMETER
OF/CI OWNER FURNISHED/CONTRACTOR
INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OVERHANG, OVERHEAD
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
OPT OPTIONAL
OR OPERATING ROOM, OUTSIDE RADIUS
ORD ORDNANCE OR OVERFLOW ROOF
DRAIN
ORG ORGANIC
ORIG ORIGINAL
ORN ORNAMENTAL
OSD OPEN SITE DRAIN
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
OVHD OVERHEAD
OUT OUTLET
OZ OUNCE
P PIPE, POLE
Pa PASCALES
PA PUBLIC ADDRESS
PAR PARALLEL OR PARAPET
PARA PARAGRAPH
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON, PUSHBUTTON
COMBINATION LOCK (STAND-ALONE)
PULL BOX
PBD PARTICLEBOARD
PC PIECE, POLYCARBONATE, PORTLAND
CEMENT, PRECAST
PCA PORTLAND CEMENT ASSOCIATION
PCC PRECAST CONCRETE
PCCP CONCRETE PAVEMENT
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PORTLAND CEMENT PLASTER
PED PEDESTAL
PEN PENETRATE
PEND PENDANT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PGBD PEGBOARD
PHAR PHARMACY
PHOTO PHOTOGRAPH
PHS PHILLIPS HEAD SCREW
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE
PJF PREFORMED JOINT FILLER
PKG PACKAGE
PL PROPERTY LINE, PLATE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PLAS CMU PLASTER COVERED CMU
PLBG PLUMBING
PLYWD PLYWOOD
PMTL PAINTED METAL
PNEU PNEUMATIC
PNL PANEL
PNT PAINT
PO POST OFFICE, PURCHASE ORDER
PO PURCHASE ORDER POST OFFICE
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRIM PRIMARY
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PRV PRESSURE RELIEF VALVE
PS PULL SWITCH
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, PRESSURE
TREATED, POINT OF TANGENT
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC), POINT
OF VERTICAL CURVE
PVG PAVING
PVI POINT OF VERTICAL INTERSECTION
PVT POINT OF VERTICAL TANGENT
PVMT PAVEMENT
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS, RISER, RUBBER, RETURN
RA RETURN AIR
RAD RADIATOR, RADIUS
RB RESILIENT BASE OR RUBBER BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REMOTE CONTROL
RCP REFLECTED CEILING PLAN,
REINFORCED CONCRETE PIPE
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
RED REDUCING
REF REFERENCE OR REFRIGERATOR
REFR REFRACTORY, REFRIGERATION
REG REGISTER, REGULATOR
REINF REINFORCE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
RESIL T RESILIENT TILE
RET RETURN
REV REVISION
REX REQUEST-TO-EXIT SWITCH
RF RADIO FREQUENCY, ROOF, RETURN
FAN
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RGS RIGID GALVANIZED STEEL
RH RIGHT HAND
RHC REHEAT COIL
RHMS ROUND HEAD MACHINE SCREW
RHR RIGHT HAND REVERSE
RHWS ROUND HEAD WOOD SCREW
RI RUBBER INSULATED
RL ROOF LEADER
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RR REMOTE RELEASE BUTTON
RS ROUGH SAWN
RT RIGHT
RV ROOF VENT
RVS REVERSE
RVT RESILIENT VINYL TILE
RWD REDWOOD
RWL RAIN WATER LEADER
S SECOND, SOUTH, SANITARY, SEWER,
STRUCTURE
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY SEWER
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL, SCHEDULE
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR,
OR SOAP DISPENSER;
SDG SIDING
SE SOUTHEAST
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SG SUPPLY GRILLE
SGD SLIDING GLASS DOOR
1PH SINGLE PHASE
SGL SINGLE
SH SHEET
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FL SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SJI STEEL JOIST INSTITUTE
SK SKETCH
SKCP SUSPENDED KEENE'S CEMENT
PLASTER
SKLT SKYLIGHT
SL SLOPE
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMH SANITARY MODULE
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
SNDU SANITARY NAPKIN DISPOSAL UNIT
SP STATIC PRESSURE, SINGLE POLE
SPC SUSPENDED PLASTER CEILING
SPDT SINGLE POLE DOUBLE THROW
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPST SINGLE POLE SINGLE THROW
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SR SUPPLY REGISTER
SS SANITARY SEWER OR SERVICE SINK
SST STAINLESS STEEL
ST STAIRS, STREET, SINGLE THROW
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL STEEL
STL JST STEEL JOIST
STL LNTL STEEL LINTEL
STL PL STEEL PLATE
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STL TR STEEL TRUSS
STNLS STAINLESS
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
STRUCT STL STRUCTURAL STEEL
SUB SUBSTITUTE
SURF SURFACE
SUP SUPPORT
SUSP SUSPEND
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
SV B SHEET VINYL BASE
SW SWITCH, SIDE WALK
SWBD SWITCHBOARD
SWDR SWING DOOR
SWGR SWITCH GEAR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
T TREAD, TILE, TOP, TANGENT
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR
TC TOP OF CURB
TCA TILE COUNCIL OF AMERICA
TCP TELEPHONE CONTROL PANEL
TEMPERATURE CONTROL PANEL;
TRAFFIC CONTROL PLAN
TD TOWEL DISPENSER
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE OR TEMPORARY
TER TERRAZZO
TERM TERMINAL
TH TOTAL HEAD (PUMPS)
THD THREAD
THERM THERMAL
THK THICKNESS
THRES THRESHOLD
THRSLD THRESHOLD
THRU THROUGH
THRUOUT THROUGHOUT
TK BD TACKBOARD
TMPD TEMPERED
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWEL RACK, TOP REGISTER
TRANS TRANSOM, TRANSITION
TRANS WD FIN TRANSPARENT WOOD FINISH
TRTD TREATED
TS TENSILE STRENGTH, TUBE STEEL, TOP
OF STEEL, TOP OF STONE, TOP OF
SLAB
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UCD UNDERCUT DOOR
UCF UNDER COUNTER FREEZER
UCR UNDER COUNTER REFRIGERATOR
UGE UNDERGROUND ELECTRIC
UGND UNDERGROUND
UGT UNDERGROUND TELEPHONE
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UNO UNLESS NOTED OTHER WISE
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT, VENT, VALVE
VA VOLT AMPRE
VAC VACUUM
VAR VARIES
VB VINYL BASE
VC VARNISH CAMBRIC, VITRIFIED CLAY, VA
SUPPLIED & CONTRACTOR INSTALLED
VCT VINYL COMPOSITION TILE, VITRIFIED
CLAY TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VPI VERTICAL POINT OF INTERSECTION
VPOC VERTICAL POINT OF CURVE
VPOT VERTICAL POINT OF TANGENT
VR VAPOR RETARDER
VS VENT STACK
VTR VENT THROUGH ROOF
VV VA SUPPLIED & INSTALLED
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W WIDE, WEST, WIDTH, WASTE, WATER,
WATT, WIRE
W/ WITH
W/O WITHOUT
WA WATT
WARR WARRANTY
WB WET BULB
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD WATER COOLER, WALL HUNG
WD WOOD, WINDOW DIMENSION
WDW WINDOW
WF WIDE FLANGE
WFAB WALL FABRIC
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WL WATER LEVEL
WLD WELDED
WM WIRE MESH
WOM WALK OFF MATT
WP WATERPROOFING, WEATHERPROOF
WPD WATER PRESSURE DROP
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP, WASTE STACK, WATER
SURFACE, WATERSTOP
WSCT WAINSCOT
WT WEIGHT
WTB WALL TILE BASE
WTL WALL TILE
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XFMR TRANSFORMER
XPS EXTRUDED POLYSTYRENE BOARD
(INSULATION)
X-STR EXISTING STRUCTURE
YD YARD
YR YEAR
1. ACCESS TO EXISTING FIRE EXITS SHALL REMAIN
OPERATIONAL DURING ALL PHASES OF CONSTRUCTION.
ENSURE ADEQUATE EGRESS CLEARANCES ARE
MAINTAINED AND NOT IMPEDED DURING CONSTRUCTION.
2. GENERAL NOTES APPLY TO ALL DRAWING SETS.
3. SUBCONTRACTORS FOR EACH TRADE ARE ADVISED THAT
INFORMATION PERTINENT TO THEIR WORK MAY OCCUR IN
OTHER PORTIONS OF THE CONTRACT DOCUMENTS. ALL
NOTES ARE TO BE REVIEWED AND APPLIED TO RELATED
BUILDING DOCUMENTS.
4. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.
IF INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS
ARE DISCOVERED FOLLOW PROCEDURES LISTED IN
SECTION 01 26 13 REQUESTS FOR INFORMATION (RFI)
BEFORE AND/OR DURING CONSTRUCTION.
5. CROSS REFERENCES SHOWN ON DRAWINGS DO NOT
NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT
LIMIT APPLICATION OF ANY DRAWING OR DETAIL. WHERE
SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT
CANNOT BE DETERMINED, FOLLOW PROCEDURES LISTED
IN SECTION 01 26 13 REQUESTS FOR INFORMATION (RFI)
PRIOR TO PROCEEDING WITH WORK.
6. REVIEW SPECIFICATIONS FOR INSTRUCTIONS NOT SHOWN
ON DRAWINGS. INFORMATION COMMON TO SEVERAL
DRAWINGS MAY BE NOTED ON ONLY ONE. CONTRACTORS
ARE RESPONSIBLE FOR CONFORMANCE TO ENTIRE SET OF
DOCUMENTS.
7. PATCH ALL HOLES IN EXISTING SURFACES WHERE
EQUIPMENT HAS BEEN REMOVED OR DEMOLITION HAS
OCCURRED AND PREPARE WALL SURFACES (PATCH, SKIM
COAT, PAINT AND FINISH TO MATCH ADJACENT SURFACES)
AS REQUIRED IN PREPARATION FOR NEW FINISHES
SCHEDULED. PATCH TO MATCH ADJACENT SURFACES IF
NOT SCHEDULED.
8. DIMENSIONS ARE TO STRUCTURAL GRIDLINE OR FACE OF
FINISHED WALL UNLESS NOTED OTHERWISE.
9. PROVIDE METAL BACKING AND/OR METAL BLOCKING IN
WALLS AT ALL WALL-MOUNTED ITEMS. VERIFY HEIGHT AND
LENGTH WITH ACTUAL EQUIPMENT. REFER TO METAL
BACKING AND BLOCKING DETAILS ON SHEET A-722. AT
EXISTING WALLS, REMOVE WALL MATERIAL TO INSTALL
METAL BACKING/BLOCKING FOR NEW WALL-MOUNTED
ITEMS.
10. ALL EXISTING FLOOR AND WALL OPENINGS AND
DEPRESSIONS NOT USED IN THE NEW WORK SHALL BE
FILLED OR CLOSED WITH MATERIALS TO MEET REQUIRED
FIRE RATING AND MATCH ADJACENT FINISHES.
11. DRAWINGS ARE NOT TO BE SCALED. CONTRACTOR TO
VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO
COMMENCING THE WORK.
12. COORDINATE WITH INTERIORS SHEETS FOR CORNER
GUARD AND WALL PROTECTION LOCATIONS AND DETAILS.
13. RADIUS EXPOSED COUNTERTOP CORNERS 2" RADIUS,
TYPICALLY. (2" WHERE 3MM EDGE BANDING, 1" RADIUS AT
PLAM EDGES.) SEE CASEWORK DETAILS.
14. CAULK ALL COUNTERTOPS, BACKSPLASHES AND CABINETS
AT LOCATIONS WHERE THEY MEET WALLS. SEAL ALL CUT-
OUTS IN COUNTERTOPS.
15. ALL CUTTING AND PATCHING REQUIRED FOR NEW
MECHANICAL AND ELECTRICAL WORK IN ALL EXISTING
SPACES SHALL BE BY THE RESPECTIVE CONTRACTORS.
16. MATCH ALL FINISHED WALL THICKNESS WHERE NEW
WALLS OCCUR IN-LINE WITH EXISTING WALLS.
17. CONTRACTOR TO PROVIDE FIRE, SMOKE, DIRT, DUST &
NOISE CONTAINMENT BARRIERS BETWEEN THE WORK
AREA & THE ADJACENT OCCUPIED SPACES. COORDINATE
THIS CONTAINMENT WITH ICRA AND ASBESTOS
ABATEMENT PROVISIONS.
18. ALL PIPING, CONDUITS, AND RELATED MECHANICAL AND
ELECTRICAL ITEMS SHALL BE CONCEALED WITHIN
DRYWALL AND/OR PLASTER FURRING AS REQUIRED IN
FINISHED AREAS WHETHER SHOWN ON DRAWINGS OR NOT
UNLESS OTHERWISE NOTED.
19. SEAL AROUND ALL MECHANICAL AND ELECTRICAL
EQUIPMENT PENETRATIONS AT RATED WALLS, ABOVE AND
BELOW CEILINGS, WITH A UL APPROVED FIRE-STOPPING
MATERIAL.
20. ALL INTERIOR WALLS WILL BE TYPE 'S' CONSTRUCTION
UNLESS OTHERWISE INDICATED. ALL FRAMING AROUND
COLUMNS WILL BE TYPE 'L2' CONSTRUCTION UNLESS
OTHERWISE INDICATED.
21. REFER TO PLAN SHEETS GI101 AND GI102 FOR INTENDED
WALL RATINGS.
22. WHEN WALL PARTITIONS OF DIFFERENT FIRE RATING
INTERSECT, THE HIGHEST RATED PARTITION TAKES
PRIORITY.
23. ALL EXISTING TO REMAIN CEILING AND WALL GRILLES,
DIFFUSERS AND LIGHTS, SPRINKLER HEADS, OCCUPANCY
AND FIRE ALARM DETECTORS TO BE CLEANED IN AREAS
OF CONSTRUCTION.
24. VERIFY THAT THE EXISTING WALLS REQUIRING FIRE
RATING ARE MAINTAINED, REPAIRED AND EXTENDED TO
STRUCTURE.
25. ALL THERMOSTAT LOCATIONS TO BE COORDINATED WITH
COR PRIOR TO INSTALLATION.
GENERAL SHEET NOTES:
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
Revisions: Date:
PIV
PIV
S S
UP
E ST
D
WH
ARCHITECTURAL SYMBOL LEGEND - DEMO
DEMOLISHED WALL, FIXTURE OR FURNISHING
EXISTING WALL, FIXTURE OR FURNISHING TO REMAIN
GENERAL DEMOLITION NOTES
A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE RATED
WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA. PROVIDE ALL
PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT WALLS SHALL BE
CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED
FIRE PROOF CAULKING MATERIAL. SEE MECHANICAL AND PLUMBING DRAWINGS
FOR ADDITIONAL INFORMATION.
B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND CONDUIT PIPING
WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL
PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
C. EXISTING DEVICES SHOWN DO NOT REPRESENT ALL DEVICES OR EXACT
LOCATIONS. CONTRACTOR TO VERIFY ALL ITEMS ONSITE PRIOR TO BIDDING.
D. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION
WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM THOSE INDICATED.
CONTRACTOR TO FIELD VERIFY IN ADVANCE THE LOCATION AND CONDITION OF
THOSE EXISTING SYSTEMS SHOWN TO BE MODIFIED OR REMOVED.
CONTRACTOR TO NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER
SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.
E. CONTRACTOR TO COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL
TRADES PRIOR TO INSTALLATION.
F. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED AT
CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
G. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS REQUIRED TO
COMPLETE THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND
RETURN TO MATCH EXISTING CONDITIONS AND FINISHES.CONTRACTOR TO
PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED EXTERIOR PIPE PENETRATIONS
AND SEAL COMPLETELY.
H. CONTRACTOR TO PROVIDE TEMPORARY FLOORING WHILE MODIFYING
SUBFLOORING.
I. ANY LANDSCAPE, HARDSCAPE, FIXTURE, SIGNAGE AND SYSTEMS OR
PEDESTRIAN CONTROL DEVICES WITHIN THE TEMPORARY ACCESSIBLE
PATHWAY SHALL BE PROTECTED IN PLACE OR TEMPORARILY RELOCATED AS
NECESSARY FOR CONTINUED UNINTERRUPTED OPERATION, ACCESS,
MAINTENANCE AND / OR VISIBILITY.
J. CONTRACTOR TO DEMO ALL ELECTRICAL, DATA, THERMOSTATS EQUIPMENT.
CAP SYSTEMS APPROPRIATELY FOR FUTURE CONNECTIONS, COORDINATE WITH
MEP.
K. SPRINKLER PROTECTION WITHIN THE CONSTRUCTION AREA THAT IS INTENDED
TO REMAIN AFTER DEMOLITION IS TO BE MAINTAINED. IN AREA OF FULL
DEMOLITION, SPRINKLER PROTECTION SHALL BE MAINTAINED UNTIL TEMPORARY
CONSTRUCTION BARRIER IS COMPLETED.
L. CONTRACTOR TO PROVIDE TEMPORARY EGRESS AND DETOUR SIGNAGE AT ALL
CONSTRUCTION BARRIERS THAT IMPACT NORMAL USE OR EGRESS PATHWAYS
IN THE EXISTING BUILDING OR COURTYARD.
KEYNOTES
NO WORK
EXISTING GRID
DOOR: EXISTING TO REMAIN / TO BE DEMOLISHED
CONSTRUCTION FENCING
CONCRETE PAVING OR SLAB TO BE REMOVED. SEE CIVIL
1X 5X 6X
M-X
P-X
Q-X
R-X
S
T
U
Y
Y'
Z
Z'
BB
CC'
EE
EE'
FF
GG
HH
P'-X
V
AA
CC
DD
2X 3X 4X
W'
X
W
11A
16 17
5' -1
6'
-9
/8
6' -9
/8
11A
F1
A-510
310 SF
SURGICAL
ANATOMIC
PATHOLOGY
153 SF
SUPERVISOR
189 SF
MECH
297 SF
MICROSCOPY
N
B1 KEY PLAN
EXISTING
PHARM
B1
B2
AREA
A
AREA
B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - THE A&E GROUP
100 Pearl Street, 14th Floor
Hartford, CT, 06103
860-270-0753
Mat Perkins
B
IM
/6
-1
-4
C o n s tr u c t N e w
I n p a ti e n t P h a rm a c y /6
-1
-4
.0 .A
R C
H .A
B l o c a ti o n .r v t
/9
/2
:2
:1
P M
AD101
ARCHITECTURAL FIRST FLOOR DEMOLITION
PLAN
689-411
B1
07/18/2024 M. PERKINS S. POLLARD
ISSUED FOR BIDDING CONSTRUCT NEW
INPATIENT PHARMACY
950 CAMPBELL AVENUE WEST HAVEN, CT 06516
1/8" = 1'-0" F1
ARCHITECTURAL FIRST FLOOR DEMOLITION PLAN
1 CONTRACTOR TO DEMOLISH BUILDING 6A - REMOVING ALL UTILITIES AND ENTRY
STAIRS PRIOR TO CONSTRUCTION. COORDINATE WITH COR PRIOR TO START TO
ENSURE BUILDING OCCUPANTS HAVE BEEN RELOCATED
2 DEMOLISH PORTION OF EXTERIOR WALL AT EXISTING DOORWAY REQUIRED FOR
NEW DOOR INTO NEW HALLWAY
3 DEMOLISH EXISTING WINDOW.
4 DEMOLISH EXISTING SIDEWALK - REFER TO CIVIL
5 EXISTING TREES TO REMAIN; PROTECT IN PLACE; REFER TO CIVIL
6 EXISTING CORRIDOR TO REMAIN IN SERVICE
7 EXISTING RAILING, DUCTWORK AND AREAWAYS TO REMAIN, PROTECT IN PLACE
8 REFER TO CIVIL FOR DEMOLITION AND RELOCATION OF UTILITIES
9 EXISTING EXTERIOR LIGHT FIXTURE TO REMAIN ; REFER TO CIVIL
10 PICNIC TABLE WITH CANOPY - SALVAGE TO OWNER
11 EXISTING EXTERIOR LIGHT FIXTURE TO BE REMOVED ; REFER TO CIVIL
11A EXISTING EXTERIOR LIGHT FIXTURE TO REMAIN; REFER TO CIVIL
12 EXISTING TREES TO BE REMOVED; REFER TO CIVIL
13 EXISTING FIRE HYDRANT TO BE RELOCATED; REFER TO CIVIL
14 EXISTING PIV TO BE REMOVED ; REFER TO CIVIL
15 DEMOLISH EXISTING ELECTRICAL J-BOXES AND CONNECTIONS. REFER TO
ELECTRICAL.
16 EXISTING PORTABLE AC UNIT TO BE RELOCATED; REFER TO CIVIL
17 EXISTING AC UNIT TO BE RELOCATED; REFER TO CIVIL. CONCRETE PAD TO BE
DEMOLISHED.
18 DEMOLISH EXISTING TRANSFORMER - REFER TO ELECTRICAL
19 CONSTRUCT CONSTRUCTION FENCING; REFER TO CIVIL.
20 EXISTING HEDGES TO BE REMOVED.
21 REMOVE STEAM VAULT TO FULLEST EXTENT POSSIBLE. STEAM LINES TO BE SAFETY
DISCONNECTED AND CUT OFF FROM INTERIOR OF SUB-BASEMENT PRIOR TO
REMOVAL OF CONCRETE VAULT. IF REMOVAL OF WALLS ABUTTING EXISTING
FOUNDATION WALLS CANNOT BE ACCOMPLISHED WITHOUT DAMAGE TO EXISTING
FOUNDATION WALLS, RETAINING THAT PORTION OF THE STEAM VAULT SHALL BE
ACCEPTABLE AT THE FINAL DETERMINATION OF THE COR.
22 TEMPORARY CONSTRUCTION BARRIER BUILT PRIOR TO DEMOLITION AND TO BE
REMOVED ONCE ADEQUATE FIRE SEPARATION IS PROVIDED BY NEW
CONSTRUCTION.
23 TEMPORARY CONSTRUCTION EGRESS AND DETOUR SIGNS AT EACH POINT OF
COURTYARD ACCESS IMPACTED BY CONSTRUCTION BARRIERS. CONTRACTOR
SHALL PHASE FENCING AND PROTECTED WORK SUCH THAT AT NO POINT WILL A
DEAD END CONDITION BE PERMITTED.
UP
9X 10X
B
B
E
E
G
G
H
H
K
K
M
M
C
C
J
J
F
F
D
D
F1
A-301
B1
A-302
B5
A-302 A
A
L
L
F1
A-510
F6
A-100
8' -8
/4
'-0
/2
/4
9' -8
/4
2' -3
'-7
/4
1/
2"
'-1
/4
1'-11 7/8" 11'-10 1/4" 1'-3 3/4" 19'-0" 3'-0" 13'-9" 8'-3" 20'-5" 23'-7" 22'-6" 9'-4" 2" 15'-2" 8'-0"
EXPN JT
4" F.O. WALL ABV
'-9
1'
-0
/4
1'-11 7/8"
30'-3 1/2" 1'-10 1/2" 92'-1 1/4" 32'-0 3/4"
1'-0"
5' -0
C
LR
F3
A-100
A-420
F8
UTILITY
TUNNEL
1655 SF
TUNNEL
STAIR
191 SF
6'-0" CLR
0100A
A
B
UTILITY
TUNNEL
01000100
1/ 8"
1'
-0
1/8" / 1'-0"
1/ 8"
1'
-0
1/8" / 1'-0"
FDTN JT 1'-0" ±
A-201
D1
1/16" / 1'-0"1/16" / 1'-0" 3"
0" -1"
0"
-1" 0" -1/2"
-1/2"
3'-0"
5' -4
/4
ELECTRICAL
MANHOLE
E0000E0000
ARCHITECTURAL SYMBOL LEGEND
GENERAL SHEET NOTES
KEYNOTES
KEY PLAN
A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE RATED
WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA. PROVIDE ALL
PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT WALLS SHALL BE
CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED
FIRE PROOF CAULKING MATERIAL. SEE MECHANICAL AND PLUMBING DRAWINGS
FOR ADDITIONAL INFORMATION.
B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND CONDUIT PIPING
WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL
PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
C. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION
WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM THOSE INDICATED.
CONTRACTOR TO FIELD VERIFY IN ADVANCE THE LOCATION AND CONDITION OF
THOSE EXISTING SYSTEMS SHOWN TO BE MODIFIED OR REMOVED.
CONTRACTOR TO NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER
SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.
D. CONTRACTOR TO COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL
TRADES PRIOR TO INSTALLATION.
E. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED AT
CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
F. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS REQUIRED TO
COMPLETE THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND
RETURN TO MATCH EXISTING CONDITIONS AND FINISHES.
G. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED EXTERIOR
PIPE PENETRATIONS AND SEAL COMPLETELY.
H. CONTRACTOR TO PROVIDE TEMPORARY FLOORING WHILE MODIFYING
SUBFLOORING.
I. ANY LANDSCAPE, HARDSCAPE, FIXTURE, SIGNAGE AND SYSTEMS OR
PEDESTRIAN CONTROL DEVICES WITHIN THE TEMPORARY ACCESSIBLE
PATHWAY SHALL BE PROTECTED IN PLACE OR TEMPORARILY RELOCATED AS
NECESSARY FOR CONTINUED UNINTERRUPTED OPERATION, ACCESS,
MAINTENANCE AND / OR VISIBILITY.
J. NEW PHARMACY FIRST FLOOR STRUCTURAL SLAB IS SET TO BE 12'-0" IN
ARCHITECTURAL DRAWINGS, THIS IS INTENDED TO BE EQUAL TO CIVIL FF=110.88'
MEASUREMENT. REFER TO CIVIL SHEET CG101 FOR ADDITIONAL ELEVATION
INFORMATION. THESE MEASUREMENTS ARE INTENDED TO ALIGN TO EXISTING
1ST FLOOR WALKWAY SLAB, VIF FINAL CONNECTION ALIGNMENT.
INTERIOR STUD FRAMED WALL. SEE WALL TYPES
AREA NOT IN CONTRACT, FACILITY TO REMAIN
OPERATIONAL
PROPOSED EXTERIOR WALL. SEE WALL SECTIONS
1 HR FIRE AND SMOKE BARRIER
2 HR FIRE AND SMOKE BARRIER
SMOKE RATED PARTITION / SMOKE BARRIER /
COMPARTMENT
1 HR FIRE RATED PARTITION
2 HR FIRE RATED PARTITION
FURNITURE, FIXTURE, & EQUIPMENT INDICATORA1000
EXISTING GRID / NEW GRID
EXISTING DOOR TO REMAIN /
NEW DOOR AND DOOR TAG
MATCHLINE
#-X #-N
XX
WALL TAG - SEE SHEET A-720 FOR ADDITIONAL INFO
XX WINDOW TAG
NEW BUILDING EXPANSION JOINT
DEDUCTIVE ALTERNATE
F1
A-301
UTILITY TUNNEL
3' - 0"
PRECAST CONCRETE HOLLOW
CORE SLAB
2" CONCRETE TOPPING
RIGID MINERAL FIBERBOARD
INSULATION
WATERPROOFING
DRAINAGE MAT
2" 8"
8' -2
10" 8'-8 5/8"
10"
1 - 2" WASHED ROCK DRAINAGE
FILTER FABRIC
4" PERFORATED PVC PIPE
FOUNDATION DRAIN
UTILITIES - SEE MEP AND CIVIL
PLANS FOR ADDITIONAL
INFORMATION
CAST-IN-PLACE CONCRETE
WALLS - SEE STRUCTURAL
CAST-IN-PLACE CONCRETE
SLAB - SEE STRUCTURAL
CONCRETE FOOTING - SEE STRUCTURAL
FLOOR 1
12' - 0"
UTILITY TUNNEL
3' - 0"
PRECAST CONCRETE HOLLOW
CORE SLAB
2" TOPPER
CAST-IN-PLACE CONCRETE WALL
3'-0" X 5'-0" HOLLOW METAL
FRAME AND LOUVERED DOOR
6' -8
DOOR SWING FOR REFERENCE
STEEL ACCESS LADDER ON
WALL BEHIND, RUNGS @ 12"
O.C. VERTICALLY, SEE DETAIL F1
AND E1 ON SHEET A-422
STEEL PLATE GRATING WELL COVER -
WELDED TO STEEL ANGLES
STEEL ANGLE LEDGES
36" X 36" STEEL PLATE GRATE ACCESS
HATCH W/ PADLOCK CONNECTION
FACE OF BUILDING BEYOND
SLOPED TOPPING POUR
PROVIDING DRAINAGE IN
WELL AND TUNNEL, TYP,
SEE PLAN.
2' -0
8" 6'
-0
RIGID MINERAL FIBERBOARD
INSULATION
DRAINAGE MAT
1 - 2" WASHED ROCK DRAINAGE
4" PERFORATED PVC PIPE
FOUNDATION DRAIN
1/8" / 1'-0" 1/8" / 1'-0"
7' -2
N
B1 KEY PLAN
EXISTING
PHARM
B1
B2
AREA
A
AREA
B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - THE A&E GROUP
100 Pearl Street, 14th Floor
Hartford, CT, 06103
860-270-0753
Mat Perkins
B
IM
/6
-1
-4
C o n s tr u c t N e w
I n p a ti e n t P h a rm a c y /6
-1
-4
.0 .A
R C
H .A
B l o c a ti o n .r v t
/9
/2
:1
:3
P M
A-100
ARCHITECTURAL UTILITY TUNNEL PLAN &
DETAILS
689-411
B1
07/18/2024 MRP CJL
ISSUED FOR BIDDING CONSTRUCT NEW
INPATIENT PHARMACY
950 CAMPBELL AVENUE WEST HAVEN, CT 06516
1/8" = 1'-0" D3
00-UTILITY TUNNEL
3/4" = 1'-0" F6
UTILITY TUNNEL SECTION
3/4" = 1'-0"
F3
UTILITY TUNNEL ACCESS WELL SECTION
1 CEILING MOUNTED STEAM PIPING - SEE MECHANICAL AND PLUMBING DRAWINGS
FOR ADDITIONAL INFORMATION.
2 ACCESS WELL - SLOPE FLOOR TO DRAIN
3 FLOOR DRAIN, SEE PLUMBING
4 FOUNDATION DRAINAGE, CONNECTS TO STORM, SEE CIVIL
5 FOUNDATION JOINT, FILL GAP BETWEEN EXISTING AND NEW WITH GRANULAR FILL
6 PNUEMATIC TUBE SYSTEM ROUTED THROUGH EXISTING EXTERIOR WALL
7 WELL IN UTILITY TUNNEL TO PERMIT MAINTENANCE ACCESS TO VERTICAL
TRANSITION OF STEAM LINES FROM SUB-BASEMENT. PROVIDE LADDER AND
FALL-PROTECTION VIA REMOVABLE STEEL GRATE. COORDINATE FINAL SIZE WITH
REQUIRED ACCESS CLEARANCE
8 EXISTING AREAWAY TO BE RETAINED
9 ELECTRICAL MANHOLE BELOW GRADE, SHOWN FOR REFERENCE ONLY, SEE CIVIL,
SEE ELECTRICAL SHEET E502.
10 WALL MOUNTED PREMANUFACTURED LADDER
DN
1X 5X 6X
M-X
P-X
Q-X
R-X
S
T
U
Y
Y'
Z
Z'
BB
CC'
EE
EE'
FF
GG
HH
P'-X
V
AA
CC
DD
2X 3X 4X
W'
X
W
A-201
D2
B
B
E
E
G
G
H
H
K
K
M
M
C
C
3' -8
'-0
8' -0
'-6
'-9
3'
-9
'-5
'-7
/2
J
J
TECHNOLOGY
12511251
CORRIDOR
12891289
RECEIVING &
INVENTORY
1255A1255A
HAC
12811281
STORAGE,
ACTIVE
12761276
CORRIDOR
12901290
HAZARD
STORAGE
1255B1255B
UNI
RESTROOM
12851285
UNI
RESTROOM
12861286
STAT
COUNTER
12751275
WORKSTATION
1256B1256B
HAZARD
DRUG
STORAGE
12661266
STERILE
HAZARD
DRUG
BUFFER
12651265
ANTE/
DECONTAMINATION
12631263
STERILE
NON-HAZARD
DRUG
BUFFER
12621262
HAC
CABINETS
1263A1263A
NON-STERILE
COMPOUNDING
1261A1261A
WORKSTATION
1256A1256A
REVERSE
DISTRBUTION/
SEGREGATED
DRUG STRG.
12721272
HALL
12871287
LIQUID/COMPLEX
REPACKAGING
12611261
REFRIG
12791279
FILLING,
ASSEMBLY &
SIMPLE
REPACKAGING
12741274
TECH
PROCESSING
12701270
RESTOCK
AND CRASH
CARTS
12671267
TECH
PROCESSING
12691269
STAFF
LOCKERS
1287A1287A
PNEUMATIC
TUBE
STATION
12711271
CORRIDOR
12561256
SECURED
DISPENSING
1276A1276A
CONTROLLED
SUBSTANCES
VAULT
1276B1276B
IV
ADMIXTURE
REFRIGERATION
12681268
STERILE
FLUIDS &
STORAGE
12551255
SUPERVISOR
OFFICES
12601260
EAST STAIR
12951295
TECH
OFFICES
12581258
PURCHASING
OFFICE
12571257
STERILE
COMPOUNDING
SUPPLIES
12641264
LOGISTICS/
ADD. STERILE
STRG
12521252
REFRIGERATION
12781278
DRUG
INFORMATION/
DISCHARGE
12731273
WORKSTATION,
PHARMACIST
12771277
CLINICAL
DIRECTOR
OFFICE
12591259
ELECTRICAL
12541254
CONFERENCE
ROOM
12841284
FUTURE
WEST STAIR
12961296
1255A
1276A
A
CORRIDOR
12891289
F
F
D
D
19'-0" 3'-0" 13'-9" 8'-3" 16'-5" 4'-0" 23'-7" 22'-6" 9'-4"
13'-4" 47'-7 7/8" 75'-3 3/4" 9'-0 3/4" ±
13'-4" TO F.O. MASONRY
1'-4 5/8" TO GRID
22'-0" 22'-0"
1'-4 3/4" TO F.O. MASONRY
42'-7 1/4" 22'-6" 9'-4"
1'-3 3/4"
3'-6" FROM F.O. MASONRY
7'-4" M.O. 6'-0" 7'-4" M.O. 6'-0" 7'-4" M.O. 6'-0" 7'-4" M.O. 16'-7 1/4" 8'-3 3/4"
9'-4 1/4"
'-0
'-6
/2
'-1
0"
2'-4" 7'-4" 3'-8"
13'-2" 19'-0" 3'-0" 13'-9" 8'-3" 20'-5" 23'-7" 22'-6" 9'-4" 15'-4" 8'-0"
2'-4" 7'-4" M.O. 3'-8 5/8" 11'-4" 7'-4" 9'-4" 7'-4" 11'-3" 6'-4" 7'-4" 13'-7" 7'-4" 15'-8" 7'-4" 8'-10" 7'-4"
10" TO F.O. MASONRY
8' -1
1/
2" S
T A
IR
'-4
/2
O V
E R
A
LL
134'-6 3/4" OVERALL 23'-9 1/4" STAIR OVERALL
47'-1" 74'-1" 23'-4"
4" EXP JT
5 1/4" 2'-2" M.O.
3'-10"
17'-4"
4" EXP JT
A-201
B2
A-201
F1
A-201
F5
F1
A-301
B1
A-302 B5
A-302
F1
A-302
5 6
TYP.
TYP.
TYP.
F
IE
LD
V
A R
IF
Y
3' -2
/4
F
IE
LD
V E
R
IF
Y
- 3 1'
-9
F1
A-351
F4
A-352
E6
A-351
E7
A-351F8
A-352
F6
A-352
A
A
1' -0
/8
5/
8"
8' -0
1'-0" 1'-0"
1' -4
O
F S
LA
B
1' -4
T
O E
D G
E
4' -1
0"
'-1 1"
8' -3
4"
'-0
F1
A-352
8'-1"
8'-1"
8'-1"
F6
A-352
SIM
F6
A-352
SIM
F6
A-352
SIM
M A
T C
H
LI
N E
E : F
4/ A
-1
B
M A
T C
H
LI
E : F
1/ A
-1
A
22'-4"
EXISTING
CORRIDOR
VESTIBULE
12881288
13'-2"
OF SLAB
1'-3" TO EDGE
F.8 L
L
2 2 2 2
1 111
A-501
F7
58 SF
STAT
COUNTER
PATIENT SIDE
'-4
/4
FEC
FEC
FEC
FEC
E6
A-351
SIM
E6
A-351
SIM
O F
S
LA
B 1'
-8
T O
E D
G E
OF SLAB
1'-4" TO EDGE
OF SLAB
1'-4 5/8" TO EDGE
OF SLAB
1'-4 3/4" TO EDGE
OF SLAB
1'-10 3/4" TO EDGE
OF SLAB
1'-6 5/8" TO EDGE
1'-6 5/8"
1' -0
A-421
F1
1288A
F1
A-510
E6
A-351
SIME6
A-351
SIM
DEDUCT ALT.#2
DEDUCT ALT.#3
DEDUCT ALT.#4
A
A
B
1295B
STAFF
LOUNGE
12831283
A
1295C
4' -4
'-8
M .O
'-2
/4
'-8
M
.O
2' -8
/4
2'-0" 2'
-4
12'-0 1/4"12'-0"
11'-2 7/8"
10'-0"
UP
10'-0"
A-201
D1
'-0
O F
S
LA
B 1'
-4
T O
E D
G E
'-1
1/
4"
VIF
15'-4" 8'-0" 4"
O F
S
LA
B 1'
-8
T O
E D
G E
O F
S
LA
B
5/ 8"
T O
E D
G E
O F
S
LA
B 1'
-9
T O
E D
G E
SUPERVISOR
11821182
SURGICAL
ANATOMIC
PATHOLOGY
11801180
CORRIDOR
1C8-011C8-01
L56 concrete on grade 5"
ARCHITECTURAL SYMBOL LEGEND
GENERAL SHEET NOTES
KEYNOTES
KEY PLAN
A. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE RATED
WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA. PROVIDE ALL
PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT WALLS SHALL BE
CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED
FIRE PROOF CAULKING MATERIAL. SEE MECHANICAL AND PLUMBING DRAWINGS
FOR ADDITIONAL INFORMATION.
B. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND CONDUIT PIPING
WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL
PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
C. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION
WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM THOSE INDICATED.
CONTRACTOR TO FIELD VERIFY IN ADVANCE THE LOCATION AND CONDITION OF
THOSE EXISTING SYSTEMS SHOWN TO BE MODIFIED OR REMOVED.
CONTRACTOR TO NOTIFY ARCHITECT SHOULD CONDITIONS BE FOUND TO DIFFER
SIGNIFICANTLY FROM CONSTRUCTION DOCUMENTS.
D. CONTRACTOR TO COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL
TRADES PRIOR TO INSTALLATION.
E. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED AT
CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
F. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS REQUIRED TO
COMPLETE THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT AND
RETURN TO MATCH EXISTING CONDITIONS AND FINISHES.
G. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED EXTERIOR
PIPE PENETRATIONS AND SEAL COMPLETELY.
H. CONTRACTOR TO PROVIDE TEMPORARY FLOORING WHILE MODIFYING
SUBFLOORING.
I. ANY LANDSCAPE, HARDSCAPE, FIXTURE, SIGNAGE AND SYSTEMS OR
PEDESTRIAN CONTROL DEVICES WITHIN THE TEMPORARY ACCESSIBLE
PATHWAY SHALL BE PROTECTED IN PLACE OR TEMPORARILY RELOCATED AS
NECESSARY FOR CONTINUED UNINTERRUPTED OPERATION, ACCESS,
MAINTENANCE AND / OR VISIBILITY.
J. NEW PHARMACY FIRST FLOOR STRUCTURAL SLAB IS SET TO BE 12'-0" IN
ARCHITECTURAL DRAWINGS, THIS IS INTENDED TO BE EQUAL TO CIVIL FF=110.88'
MEASUREMENT. REFER TO CIVIL SHEET CG101 FOR ADDITIONAL ELEVATION
INFORMATION. THESE MEASUREMENTS ARE INTENDED TO ALIGN TO EXISTING
1ST FLOOR WALKWAY SLAB, VIF FINAL CONNECTION ALIGNMENT.
INTERIOR STUD FRAMED WALL. SEE WALL TYPES
AREA NOT IN CONTRACT, FACILITY TO REMAIN
OPERATIONAL
PROPOSED EXTERIOR WALL. SEE WALL SECTIONS
1 HR FIRE AND SMOKE BARRIER
2 HR FIRE AND SMOKE BARRIER
SMOKE RATED PARTITION / SMOKE BARRIER /
COMPARTMENT
1 HR FIRE RATED PARTITION
2 HR FIRE RATED PARTITION
FURNITURE, FIXTURE, & EQUIPMENT INDICATORA1000
EXISTING GRID / NEW GRID
EXISTING DOOR TO REMAIN /
NEW DOOR AND DOOR TAG
MATCHLINE
#-X #-N
XX
WALL TAG - SEE SHEET A-720 FOR ADDITIONAL INFO
XX WINDOW TAG
NEW BUILDING EXPANSION JOINT
DEDUCTIVE ALTERNATE
N
B1 KEY PLAN
EXISTING
PHARM
B1
B2
AREA
A
AREA
B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - THE A&E GROUP
100 Pearl Street, 14th Floor
Hartford, CT, 06103
860-270-0753
Mat Perkins
B
IM
/6
-1
-4
C o n s tr u c t N e w
I n p a ti e n t P h a rm a c y /6
-1
-4
.0 .A
R C
H .A
B l o c a ti o n .r v t
/9
/2
:1
:4
P M
A-101
ARCHITECTURAL FLOOR PLAN - FIRST FLOOR -
OVERALL
689-411
B1
07/18/2024 M. PERKINS K. BICKEL
ISSUED FOR BIDDING CONSTRUCT NEW
INPATIENT PHARMACY
950 CAMPBELL AVENUE WEST HAVEN, CT 06516
1/8" = 1'-0" F1
ARCHITECTURAL FLOOR PLAN - FIRST FLOOR - OVERALL
1 EAST WEST POINT OF ORIGIN FOR DIMENSIONS AT WEST FACE OF EXISTING
BUILDING. NORTH SOUTH POINT OF ORIGIN AT CORNER OF BRICK WALL.
2 4" EXPANSION JOINT BETWEEN NEW AND EXISTING CONSTRUCTION, TYP.
3 SLOPE FLOOR TO DRAIN
4 WINDOWS WITH # 304 STAINLESS STEEL WOVEN SECURITY MESH SECURELY
ANCHORED TO INTERIOR WINDOW FRAME AND INTRUSION DETECTION ALARM THAT
ANNUNCIATES IN THE SECURITY CONTROL CENTER
5 DOOR AND LOCK STATUS SENSORS AND MOTION SENSORS IN PHARMACY
6 PHARMACY ENTRIES AND NARCOTIC VAULTS MUST BE CONTROLLED VIA CARD
READERS
7 CCTV MUST BE USED AT ENTRY POINTS, EXIT POINTS SERVICE INTERACTION AREA
AND WINDOWS AND WAITING AREAS
8 WALK-IN REFRIGERATION / FREEZER ASSEMBLY WITH DOOR. FRAME WALL AROUND
UNIT TO ENCLOSE.
9 SECURITY AND BULLET RESISTANT WALL & WINDOW SYSTEM AND PASS THRU AT
STAT COUNTER (UL 752 LEVEL 3 BALLISTIC CONSTRUCTION AND 15 MINUTE FORCED
ENTRY RESISTANT)
10 ALL VENTS, DUCTS, AND SIMILAR OPENINGS IN EXCESS OF 96 SQUARE INCHES THAT
PASS THROUGH A PERIMETER PARTITION SHALL BE PROTECTED WITH BARS OR
GRILLS OF 1/2" DIAM STEEL WELDED VERTICALLY AND HORIZONTALLY 6" ON CENTER
OR GRILLS OF 9 GAUGE EXPANDED STEEL
11 SITE PAVING, SEE CIVIL FOR MORE INFORMATION
12 NEW MECHANICAL EQUIPMENT, REFER TO MECHANICAL PLANS.
13 EXISTING RAILING, DUCTWORK AND AREAWAYS TO REMAIN, PROTECT IN PLACE
14 UTILITY TUNNEL ACCESS WELL - SEE A-100.
15 FLOOR SINK.
16 DRINKING FOUNTAIN
17 NEW ACCESS GATE TO CONNECT TO AREAWAY EXISTING GUARDRAIL.
18 WALK-OFF GRATE IN SLAB DEPRESSION, PROVIDE DRAINAGE AWAY FROM DOOR
19 COLUMN SURROUND TO MEET UL BXUV.X528 SYSTEM(DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE
ORDER PRESENTED)
DEDUCT ALTERNATE #1: REMOVE EXTERIOR THIN CONCRETE AND METAL
PANEL SYSTEM; CHANGE TO EIFS SYSTEM ON EXTERIOR ENVELOPE SYSTEM.
DEDUCT ALTERNATE #2: ELIMINATE 280 S.F. OF STORAGE SPACE
DEDUCT ALTERNATE #3: ELIMINATE THE CONFERENCE ROOM, STAFF LOCKER
ROOM AND STAFF LOUNGE, 600 S.F
DEDUCT ALTERNATE #4: ELIMINATE 425 S.F. OF OFFICE SPACE
DEDUCTIVE ALTERNATES: SHOWN ON THIS SHEET #2, #3,#4
EQUAL TO CIVIL
FF=110.88'
EQUAL TO CIVIL
FF=110.88'
EQUAL TO CIVIL
108.51'
DN
B E G
C
TECHNOLOGY
ACTUAL: 116 SF
PROG: 30 SF
CORRIDOR
ACTUAL: 1231 SF
PROG: 0 SF
HAC
ACTUAL: 46 SF
PROG: 60 SF
UNI
RESTROOM
ACTUAL: 59 SF
PROG: 60 SF
UNI
RESTROOM
ACTUAL: 60 SF
PROG: 60 SF
STAT
COUNTER
ACTUAL: 44 SF
PROG: 65 SF
WORKSTATION
1256B
ACTUAL: 49 SF
PROG: 60 SF
HAZARD
DRUG
STORAGE
ACTUAL: 151 SF
PROG: 150 SF
55 5 5
STERILE
HAZARD
DRUG
BUFFER
ACTUAL: 249 SF
PROG: 250 SF
ANTE/
DECONTAMINATION
ACTUAL: 171 SF
PROG: 120 SF
STERILE
NON-HAZARD
DRUG
BUFFER
ACTUAL: 251 SF
PROG: 250 SF
HAC
CABINETS
1263A
ACTUAL: 28 SF
PROG: 15 SF
NON-STERILE
COMPOUNDING
1261A
ACTUAL: 43 SF
PROG: 40 SF
WORKSTATION
1256A
ACTUAL: 44 SF
PROG: 60 SF
REVERSE
DISTRBUTION/
SEGREGATED
DRUG
STRG.
ACTUAL: 63 SF
PROG: 0 SF
HALL
ACTUAL: 218 SF
PROG: 0 SF
LIQUID/COMPLEX
REPACKAGING
ACTUAL: 220 SF
PROG: 250 SF
FILLING,
ASSEMBLY
& SIMPLE
REPACKAGING
ACTUAL…