A3 Revision 1 A600 - BUILDING SECTIONS - R1_SS.pdf
PDF 555 KB Posted
- Solicitation number
- W50S8K26QA002
About this file
This is an architectural drawing document containing building sections for a covered parking structure. The project is located at Jefferson Barracks, 4141 May Road, St. Louis, Missouri 63125, and is identified as Building 4141 Covered Parking. The drawing was prepared by BranchPattern, Inc., a civil engineering, surveying, utilities, and construction services firm based in Overland Park, Kansas, and was designed by Douglas B Loveland, a licensed architect in Missouri.
The drawing depicts a canopy section with specific structural and dimensional requirements, including a clearance height of 463'-6", grade elevations ranging from 448'-4" to 451'-6", and roof dimensions of approximately 24'-0" in length. The document includes four alternates for bid consideration: Alternate 1 (base scope with PV panel system and AESS3 primed and painted exposed steel with safety yellow concrete footings), Alternate 2 (addition of waterproof duplex receptacles at specific columns), Alternate 3 (deletion of PV panel system and addition of standing seam metal roof with installation shop drawings), and Alternate 4 (addition of gutter and downspout systems with 6" Style "A" gutters and 4" downspouts). The drawing is marked as preliminary for review purposes only and is not for construction or implementation. The document revision date is August 27, 2024, with the initial submittal dated July 2, 2024, at 100% Construction Documents level.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S. GRADE - LOW
449'-1"
S. GRADE - HIGH
451'-6"
CLEARANCE
HEIGHT
463'-6"
A
T.O. FOOTING
453'-3"
N. GRADE HIGH
451'-0 101/256"
N. GRADE LOW
448'-4 37/256"
T.O. COLUMN
465'-9"
B.O. FOOTING
443'-3"
(S E
E S
T R
U C
T U
R A
L
(S O
U T
H C
A N
O P
Y M
IN
IM
U M
C L
E A
R A
N C
E
(N O
R T
H C
A N
O P
Y M
IN
IM
U M
C L E
A R
A N
C E
/2
2 1/8"
12"
A600
24'-0"
23'-7 1/2" +/-
NOTE: VERIFY OVERALL
ROOF DIMENSIONS WITH
FINAL SOLAR PANEL
INSTALL DIMENSIONS
ALTERNATE 4: ADD GUTTER AND
DOWNSPOUTS; 6" STYLE "A"
GUTTER, 4" DOWNSPOUT AT
EACH COLUMN, PROVIDE AND
INSTALL BRACKETS AS
REQUIRED, PREFINISHED TO
MATCH STEEL PAINT
ALTERNATE 3: DELETE PV
PANEL SYSTEM AND ADD
STANDING SEAM METAL ROOF;
PROVIDE INSTALLATION SHOP
DRAWINGS
EXPOSED STEEL TO BE AESS3,
PRIMED AND PAINTED, TYP.
ALTERNATE 2: PROVIDE
WATERPROOF DUPLEX
RECEPTACLE AT SECOND AND
FIFTH COLUMNS, TYP.; SEE
ELECTRICAL
PAINT EXPOSED CONCRETE
FOOTINGS SAFETY YELLOW,
TYP.
CLEARANCE
HEIGHT
463'-6"
ALTERNATE 4: ADD GUTTER AND
DOWNSPOUTS; 6" STYLE "A"
GUTTER, 4" DOWNSPOUT AT
EACH COLUMN, PROVIDE AND
INSTALL BRACKETS AS
REQUIRED, PREFINISHED TO
MATCH STEEL PAINT
ALTERNATE 3: DELETE PV
PANEL SYSTEM AND ADD
STANDING SEAM METAL ROOF;
PROVIDE INSTALLATION SHOP
DRAWINGS
SEE STRUCTURAL
PRELIMINARY
DRAWINGS FOR
REVIEW
PURPOSES ONLY,
NOT FOR
CONSTRUCTION
OR
IMPLEMENTATION
www.branchpattern.com
BETTER BUILT ENVIRONMENTS
Phone: 800-200-9160
These drawing and the designs here Illustrated are the sole property of BranchPattern, Inc. and may not be reproduced in whole or in part without express written permission.
Designed By:
Drawn By:
Reviewed By:
Project No:
Date:
Submittal Level:
Sheet Title:
Sheet No.:
1218003
Seal:
Civil Engineering | Surveying | Utilities | Construction Services 7101 College Blvd., Ste. 400 Overland Park, KS 66210 o: (913) 663-1900
P R
O J E
C T
N A
M E
TM
TM
07/02/2024
A600
BUILDING SECTIONS
100% CD
KM
J E
F F
E R
S O
N B
A R
R A
C K
S C
O V
E R
E D
P A
R K
IN
G
B
U
IL
D
IN
G
M
A Y
R O
A D
S T
L
O U
IS
M O
1/2" = 1'-0"1 CANOPY SECTION
1" = 1'-0"3 LOWER ROOF EDGE DETAIL
Description Date
REVISION 1 8/27/24
Seal:
D ou gl as
B L ov el an d
A rc hi te ct M
O A
-2
77/
2/
| Sheets |
| A600 - BUILDING SECTIONS |
File details come from the government source that posted it. Updated .