Construction Documents Summary
These are construction documents for the replacement of HVAC systems at the Liberty Square Visitor Education Center within Fort Sumter and Fort Moultrie National Historical Park in Charleston, South Carolina. The project (PMIS # 316098B, Package 392, Drawing Set 192499) includes comprehensive mechanical, structural, and electrical design specifications prepared by licensed professional engineers for the National Park Service Southeast Region.
The mechanical scope encompasses demolition of existing mini-split units, fan coil units, dehumidification equipment, and associated ductwork across three levels (Pier West, Pier East, First Floor West, First Floor East, and Second Floor), followed by installation of new equipment including two 40-ton chillers, two condensing boilers, six air handling units with heating and cooling coils, make-up air units, chilled and heating water pump systems, exhaust fans, a desiccant dehumidifier, and interconnected piping and ductwork systems. The electrical work involves new disconnects, conduit, wiring, and modifications to existing panels to support the HVAC equipment. Structural modifications include concrete equipment pads sized for the new chiller installation and modifications to support systems. The contract documents establish general requirements including contractor responsibility for job site safety, utility location verification through DIG ALERT, erosion and sediment control, work restrictions (7:30 AM to 4:00 PM Monday-Friday), equipment power-washing prior to park entry, and submission of record drawings upon completion. All work must conform to NPS standards, state and local codes, and SMACNA standards for ductwork installation.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE OF MILES
1 0 1
SCALE OF METERS
SCALE OF FEET
2,000
0 4,000
500 1,000
2,000
SOUTH CAROLINA
STATE
NATIONAL PARK SERVICE
SOUTHEAST REGION REGION COUNTY
DEPARTMENT OF THE INTERIOR
UNITED STATES LOCATION WITHIN PARK
NAME OF PARK
TITLE OF DRAWING
REPLACE HVAC SYSTEMS AT LIBERTY SQUARE VISITOR EDUCATION CENTER
LIBERTY SQUARE
192499
098B
44CHARLESTON S. CAROLINA
CONSTRUCTION DOCUMENTS
PMIS # 316098B
OF
PKG.
NO. SHEET
DRAWING NO.
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
SOUTHEAST
CHARLESTON
392/92,002 6/91; 392/90,027 9/90; REVISED & REDRAWN 6/93. UPDATED 11/98. SGS.
SUMTER
SITE
FORT
MOULTRIE
SITE
PROJECT
SITE
FORT
SHEET LIST TABLE
PAGE NO. SHEET NO. SHEET TITLE
GENERAL
1 G0.0 COVER SHEET
2 G0.1 GENERAL NOTES
3 G0.2 SITE MAP
STRUCTURAL
4 S1.0 PIER WEST STRUCTURAL PLAN
5 S1.1 FIRST FLOOR EAST STRUCTURAL PLAN
6 S1.2 SECOND FLOOR STRUCTURAL PLAN
7 S5.0 DETAILS
MECHANICAL
8 M0.0 MECHANICAL LEGEND & ABBREVIATIONS
9 M1.0 PIER WEST HVAC DEMO PLAN
10 M1.1 PIER EAST HVAC DEMO PLAN
11 M1.2 FIRST FLOOR WEST HVAC DEMO PLAN
12 M1.3 FIRST FLOOR WEST PIPING DEMO PLAN
13 M1.4 FIRST FLOOR EAST HVAC DEMO PLAN
14 M1.5 FIRST FLOOR EAST PIPING DEMO PLAN
15 M1.6 SECOND FLOOR HVAC DEMO PLAN
16 M1.7 SECOND FLOOR PIPING DEMO PLAN
17 M1.8 PIER WEST HVAC NEW PLAN
18 M1.9 PIER EAST HVAC NEW PLAN
19 M1.10 FIRST FLOOR WEST HVAC NEW PLAN
20 M1.11 FIRST FLOOR WEST PIPING NEW PLAN
21 M1.12 FIRST FLOOR EAST HVAC NEW PLAN
22 M1.13 FIRST FLOOR EAST PIPING NEW PLAN
23 M1.14 SECOND FLOOR HVAC NEW PLAN
24 M1.15 SECOND FLOOR PIPING NEW PLAN
25 M3.0 SECTIONS
26 M5.0 DETAILS
27 M5.1 DETAILS
28 M5.2 DETAILS
29 M6.0 SCHEDULES
ELECTRICAL
30 E0.0 ELECTRICAL LEGEND AND ABBREVIATIONS
31 E1.0 ELECTRICAL DEMO PIER WEST PLAN
32 E1.1 ELECTRICAL DEMO PIER EAST PLAN
33 E1.2 ELECTRICAL DEMO FIRST FLOOR WEST PLAN
34 E1.3 ELECTRICAL DEMO FIRST FLOOR EAST PLAN
35 E1.4 ELECTRICAL DEMO SECOND FLOOR PLAN
36 E1.5 ELECTRICAL NEW PIER WEST PLAN
37 E1.6 ELECTRICAL NEW PIER EAST PLAN
38 E1.7 ELECTRICAL NEW FIRST FLOOR WEST PLAN
39 E1.8 ELECTRICAL NEW FIRST FLOOR EAST PLAN
40 E1.9 ELECTRICAL NEW SECOND FLOOR PLAN
41 E6.0 SINGLE LINE DIAGRAM
42 E6.1 EXISTING SCHEDULES A
43 E6.2 NEW SCHEDULES B
44 E6.3 SCHEDULES C
THIS PROJECT
SO
UTH CAROLINA
JOSEPH EIXENBERGER
LIC
EN
SE
D
PROFESSIONAL ENGINEERNo. 39592
SO
UTH CAROLINA
LIC
EN
SE
D
PROFESSIONAL ENGINEERNo. 42216
CHR IST IA N GELLERT
SO
UTH CAROLINA
LIC
EN
SE
D
PROFESSIONAL ENGINEERNo. 40622
P. V INSO N C A RTER
6-17-2024
6-14-20246-4-2024
AutoCAD SHX Text
CONCORD ST.
AutoCAD SHX Text
BROAD ST.
AutoCAD SHX Text
TRADD ST.
AutoCAD SHX Text
CALHOUN ST.
AutoCAD SHX Text
MEETING ST.
AutoCAD SHX Text
DRUM
AutoCAD SHX Text
ISLAND
AutoCAD SHX Text
CHARLESTON
AutoCAD SHX Text
DOCKSIDE II
AutoCAD SHX Text
COOPER RIVER
AutoCAD SHX Text
ASHLEY RIVER
AutoCAD SHX Text
AutoCAD SHX Text
CITY
AutoCAD SHX Text
MARINA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FORT SUMTER
AutoCAD SHX Text
NATIONAL
AutoCAD SHX Text
MONUMENT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ATLANTIC
AutoCAD SHX Text
OCEAN
AutoCAD SHX Text
SULLIVAN'S
AutoCAD SHX Text
ISLAND
AutoCAD SHX Text
MORRIS
AutoCAD SHX Text
ISLAND
AutoCAD SHX Text
JAMES
AutoCAD SHX Text
ISLAND
AutoCAD SHX Text
DANIEL
AutoCAD SHX Text
ISLAND
AutoCAD SHX Text
CHARLESTON
AutoCAD SHX Text
MOUNT
AutoCAD SHX Text
PLEASANT
AutoCAD SHX Text
COOPER RIVER
AutoCAD SHX Text
ASHLEY RIVER
AutoCAD SHX Text
CO.
AutoCAD SHX Text
BERK
AutoCAD SHX Text
LEY
AutoCAD SHX Text
CHAR
AutoCAD SHX Text
ESTON
AutoCAD SHX Text
CO.
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text
AutoCAD SHX Text
LONG POINT ROAD
AutoCAD SHX Text
MATHIS
AutoCAD SHX Text
FERRY
AutoCAD SHX Text
RIFLE RANGE
AutoCAD SHX Text
ROAD
AutoCAD SHX Text 7/16/19 11:00 MTRACY R22 P:\FOSU\FOUNDATION\0.0 PRIMARY DOCUMENT\FOSU 105DB-HVAC RACDS\GEN\01-COVER 105DB HVAC.DWG
AutoCAD SHX Text
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
GENERAL NOTES
1. ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH NPS STANDARDS AND STATE AND
LOCAL STANDARDS.
2. SURVEY/ ELEVATIONS SHOWN ON THE PLANS ARE TO BE USED BY THE CONTRACTOR TO
DETERMINE APPROXIMATE FIELD CONDITIONS. ACTUAL ELEVATIONS SHALL BE FIELD
VERIFIED DURING CONSTRUCTION.
3. IN GENERAL, EXISTING STRUCTURES, EQUIPMENT, AND FACILITIES ARE SHOWN AS A
SCREENED BACKGROUND. NEW STRUCTURES, EQUIPMENT, AND FACILITIES ARE SHOWN IN
HEAVY LINE WEIGHTS. OTHER DISCIPLINES MAY SCREEN NEW STRUCTURES OUTSIDE THEIR
DISCIPLINE TO SHOW THEIR INFORMATION.
4. ALL WORK SHALL BE PERFORMED PER THE APPROVED PLANS, PROJECT SPECIFICATIONS AND
GENERAL CONDITIONS OF THE CONTRACT. ANY CHANGES TO THE DESIGN AS SHOWN IN
THESE CONSTRUCTION DOCUMENTS MUST BE REVIEWED AND APPROVED BY THE
CONTRACTING OFFICER BEFORE CHANGES ARE MADE.
5. BY ACCEPTING AND USING THESE DRAWINGS, CONTRACTOR AGREES THAT HE/SHE SHALL
ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE
COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY; THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS. IN ADDITION, THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND
HOLD THE NPS AND THE OWNER'S REPRESENTATIVE HARMLESS FROM ANY AND ALL LIABILITY,
REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING THE LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE NPS OR THE
OWNER'S REPRESENTATIVE.
6. ANY KNOWN SEWERS, WATER MAINS, TELEPHONE CONDUITS, ELECTRIC CABLES, AND OTHER
UNDERGROUND/OVERHEAD ITEMS ARE SHOWN ON THE DRAWINGS ONLY TO THE EXTENT
SUCH INFORMATION HAS BEEN MADE AVAILABLE OR DISCOVERED BY THE ENGINEER. IT IS
EXPECTED THAT THERE MAY BE DISCREPANCIES AND OMISSIONS IN THE LOCATION AND
QUANTITIES OF EXISTING UTILITIES AND STRUCTURES SHOWN. THIS INFORMATION IS SHOWN
FOR THE CONVENIENCE OF THE CONTRACTOR BUT IS NOT GUARANTEED TO BE EITHER
CORRECT OR COMPLETE AND ALL RESPONSIBILITY FOR THE ACCURACY AND COMPLETENESS
THEREOF IS EXPRESSLY DISCLAIMED. THE CONTRACTOR IS RESPONSIBLE FOR FIELD
LOCATING WATER, SEWER, ELECTRIC, PHONE AND ALL OTHER EXISTING UTILITIES IN THE
PROJECT LIMITS VIA POT HOLING, 3RD PARTY UTILITY LOCATOR, ETC. AS NECESSARY TO
VERIFY LOCATIONS, CORRECTNESS, & COMPLETENESS.
7. THE CONTRACTOR SHALL CONTACT DIG ALERT TO CREATE A CONTRACTOR TICKET FOR THE
LOCATION OF EXISTING UTILITIES AT LEAST FIVE (5) WORKING DAYS PRIOR TO THE BEGINNING
OF WORK. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PRE-MARKING OF THE
LOCATION LIMITS AS REQUIRED BY DIG ALERT. CONTRACTOR MAY NOT BEGIN EXCAVATION
UNTIL ALL UTILITY MEMBERS HAVE RESPONDED TO THEIR TICKET.
8. DIMENSIONS SHOWN ON THE PLANS ARE TO BE USED BY THE CONTRACTOR TO DETERMINE
APPROXIMATE FIELD CONDITIONS. PRIOR TO CONSTRUCTION CONTRACTOR SHALL FIELD
VERIFY EXISTING LOCATIONS, ELEVATIONS, MATERIAL TYPES, I.D. AND O.D. OF PIPES, ETC. OF
ALL UTILITIES AND FEATURES WHERE PROPOSED IMPROVEMENTS CONNECT. NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES IN WRITING IMPACTING NEW WORK
SUFFICIENTLY IN ADVANCE OF NEW WORK SO AS TO NOT CAUSE CONSTRUCTION DELAYS.
INCLUDE INFORMATION ON LOCATION, ELEVATION , UTILITY TYPE AND SIZE.
9. EXISTING FACILITIES, INCLUDING BUT NOT LIMITED TO ROADS, WALLS, FENCES, STRUCTURES
AND UTILITIES, DAMAGED BY CONTRACTOR'S OPERATIONS SHALL BE RESTORED TO MATCH
ORIGINAL PRE-CONSTRUCTION CONDITION AND TO THE SATISFACTION OF THE CONTRACTING
OFFICER WITHOUT ADDITIONAL COST TO THE GOVERNMENT
10. ALL DISTURBED ASPHALT, GRASS, DRAINAGE PATTERNS, ROADSIDE DITCHES, TRAILS AND
GRADE SHALL BE RESTORED TO ITS ORIGINAL CONDITION OR AS CALLED FOR ON THE
CONTRACT DOCUMENTS, WHICHEVER IS MORE STRINGENT.
11. CONTRACTOR SHALL FURNISH AND INSTALL EVERYTHING REQUIRED TO PROVIDE COMPLETE
AND OPERABLE FACILITIES AS SHOWN HEREIN. IF THERE IS AN OMISSION ON THE
CONSTRUCTION DOCUMENTS, SUCH OMISSION SHALL NOT BE CONSTRUED TO MEAN THAT
THE CONTRACTOR IS NOT REQUIRED TO FURNISH OR PROVIDE EVERYTHING THAT IS
NECESSARY TO PROVIDE COMPLETE AND OPERABLE FACILITIES.
12. ALL CONTRACTORS WORKING WITHIN THE PROJECT BOUNDARIES ARE RESPONSIBLE FOR
COMPLIANCE WITH ALL APPLICABLE SAFETY LAWS. CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL EMPLOYEES AND/OR SUBCONTRACTORS WITH PERSONAL PROTECTIVE
EQUIPMENT AND FOLLOWING ALL SAFETY PROTOCOLS, TO INCLUDE WORK IN ATTIC AND
CRAWL SPACES IN THE EVENT RODENT DROPPINGS/NESTS ARE PRESENT.
13. ALL EXISTING VALVES AND EQUIPMENT SHALL BE OPERATED BY THE NPS UTILITIES
OPERATOR, OR IN THE OBSERVANCE OF THE OPERATOR WITH PRIOR APPROVAL.
14. CONTRACTOR TO SUBMIT SERVICE INTERRUPTION PLAN AND NOTIFY NPS CONTRACTING
OFFICER AT LEAST 72 HOURS PRIOR TO ANY UTILITY OR SERVICE INTERRUPTIONS.
15. CONTRACTOR SHALL PROVIDE TRACER WIRE AND LOCATOR TAPE FOR ALL BURIED PIPING
AND CONDUITS.
16. ALL COSTS INCURRED IN CORRECTION OF DEFICIENT WORK SHALL BE THE RESPONSIBILITY OF
THE CONTRACTOR.
17. UPON THE COMPLETION OF WORK, THE CONTRACTOR SHALL SUBMIT A SET OF “RED-LINED”
RECORD DRAWINGS TO THE CONTRACTING OFFICER SHOWING ALL DEVIATIONS, CHANGES,
ADDITIONS, AND DELETIONS MADE DURING CONSTRUCTION. ONE SET SHALL BE MAINTAINED
AT THE SITE AND SHALL BE UPDATED DAILY.
18. STAGING AREAS SHALL BE DEFINED BY CONTRACTING OFFICER UNLESS OTHERWISE
DELINEATED IN THIS PLAN SET.
19. CONSTRUCTION FENCING OR BARRIERS SHALL BE PROVIDED WHERE NECESSARY TO
PREVENT THE PUBLIC OR PARK STAFF FROM ENTERING WORK AREAS.
20. CONTRACTOR SHALL MAINTAIN VEHICULAR AND PEDESTRIAN TRAFFIC ON ALL EXISTING
DRIVEWAYS, ROADS AND PATHS NOT UNDER CONSTRUCTION. ALL DRIVEWAYS AND STREET
APPROACHES SHALL BE OPENED TO ALLOW VEHICLE ACCESS AT THE END OF THE WORK DAY.
CONTRACTOR SHALL COORDINATE WITH NPS AND PREPARE A TRAFFIC AND PEDESTRIAN
CONTROL PLAN FOR ALL AREAS AFFECTED BY CONSTRUCTION.
21. ALL EXISTING TREES TO REMAIN UNLESS OTHERWISE SPECIFIED.
22. ESTABLISHMENT OF A CONSTRUCTION CAMP WILL NOT BE PERMITTED WITHIN PARK
BOUNDARIES.
23. THE CONTRACTOR SHALL END PLACEMENT FOR ALL SURFACE CONCRETE WORK AT EITHER
EXPANSION OR CONSTRUCTION JOINTS.
24. THE NPS SHALL IMMEDIATELY BE NOTIFIED IN WRITING BY THE CONTRACTOR OF ANY
IDENTIFIED CONDITIONS THAT REQUIRE DEVIATIONS FROM THESE PLANS AND/OR
SPECIFICATIONS. ANY REVISIONS TO THE IMPROVEMENT PLAN WILL BE PROCESSED IN
ACCORDANCE WITH THE SPECIFICATIONS AND CONTRACT DOCUMENTS.
25. ALL EXCAVATIONS 5' IN DEPTH OR GREATER SHALL BE SHORED AND BRACED ACCORDING TO
OSHA REGULATIONS.
26. UNLESS OTHERWISE INDICATED, DEMOLISHED MATERIALS BECOME THE PROPERTY OF THE
CONTRACTOR. COMPLY WITH EPA REGULATIONS AND DISPOSAL REGULATIONS OF
AUTHORITIES HAVING JURISDICTION. CONDUCT ANY DEMOLITION DUTIES WITHOUT
DISRUPTION OF OCCUPANTS.
27. ALL EXISTING FACILITIES AND UTILITIES SHALL BE PROTECTED UNLESS NOTED TO BE
REMOVED ON THE DRAWINGS.
28. PIPE DEFLECTION SHALL BE PER MANUFACTURERS RECOMMENDATION.
29. THRUST BLOCKING SHALL BE PLACED AT ALL BENDS (HORIZONTAL OR VERTICAL) 11.25
DEGREES OR GREATER, AND AS SHOWN IN THE STANDARD DETAILS.
30. PIPE SUPPORTS SHALL BE INSTALLED AS SHOWN ON THE PLANS, AS DEEMED NECESSARY IN
THE FIELD, OR AS DIRECTED BY THE CONTRACTING OFFICER FOR SUPPORT OF ALL PIPING
BOTH NEW AND EXISTING.
31. ALL VALVE RISERS ON VALVES ABANDONED IN THE CURRENT PROJECT SHALL BE REMOVED
UNLESS OTHERWISE NOTED TO RETAIN.
32. ALL MECHANICAL JOINTS SHALL BE RESTRAINED IN ACCORDANCE WITH THE PROJECT
SPECIFICATION. MECHANICAL JOINT RESTRAINT SHALL BE UNI-FLANGE 1300 (SERIES) OR
APPROVED EQUAL.
33. ALL LABORATORY AND FIELD MATERIALS TESTING SHALL BE DONE IN ACCORDANCE WITH THE
SPECIFICATIONS.
34. SINCE THIS CONSTRUCTION PROJECT WILL DISTURB LESS THAN ONE-ACRE, THE
CONTRACTOR WILL NOT NEED TO FILE AND SUBMIT A NOTICE OF INTENT (NOI) OR A STORM
WATER POLLUTION PREVENTION PLAN (SWPPP). THE CONTRACTOR SHALL PREPARE THE
UNDER-AN-ACRE POLLUTION PREVENTION PLAN MEETING THE REQUIREMENTS OF THE
NATIONAL PARK SERVICE FOR CONSTRUCTION ACTIVITIES.
35. SEE SPECIFICATIONS FOR ADDITIONAL PROJECT REQUIREMENTS.
EROSION & SEDIMENT CONTROL NOTES
1. ALL EQUIPMENT SHALL BE POWER WASHED BY THE CONTRACTOR AND INSPECTED BY A PARK
REPRESENTATIVE PRIOR TO THE EQUIPMENT ENTERING THE PARK TO ENSURE IT IS FREE OF
NON-NATIVE WEEDS AND/OR SEEDS AS WELL AS OIL LEAKS (CONTRACTOR IS RESPONSIBLE
FOR PREPARATION AND CLEANING OF ALL EQUIPMENT AND FOR COORDINATING THE
INSPECTION WITH THE NATIONAL PARK SERVICE AT LEAST 48 HOURS IN ADVANCE). IN
ADDITION, SOURCES OF IMPORTED ROCK, SAND, GRAVEL, AND SOIL SHALL BE INSPECTED BY
THE NATIONAL PARK SERVICE FOR INVASIVE NON-NATIVE PLANTS, WEEDS AND/OR SEEDS
(THE NATIONAL PARK SERVICE SHALL BE NOTIFIED 30 CALENDAR DAYS IN ADVANCE FOR ALL
IMPORT SOURCE INSPECTIONS.
2. CONTRACTOR SHALL PROVIDE, MAINTAIN, AND BE RESPONSIBLE FOR ALL EROSION AND
SEDIMENT CONTROL STRUCTURES AND PRACTICES IN ACCORDANCE WITH THE PARK'S BEST
MANAGEMENT PRACTICES AS WELL AS ANY LOCAL, STATE, AND FEDERAL REQUIREMENTS FOR
WATER QUALITY AND EROSION AND SEDIMENT CONTROL. EXCELSIOR OR COIR FIBER
PRODUCTS SHALL BE USED IN EROSION CONTROL BLANKETS AND SEDIMENT LOGS. JUTE OR
COTTON SHALL BE USED FOR NETTING IN EROSION CONTROL BLANKETS. NO “CERTIFIED
WEED FREE” PRODUCTS ARE ALLOWED. NO PLASTIC NETTING PRODUCTS ARE ALLOWED.
3. CONTRACTOR TO PRESERVE EXISTING VEGETATION AND MINIMIZE THE AREAS DISTURBED BY
CONSTRUCTION ACTIVITY.
4. CONTRACTOR SHALL PROVIDE INLET PROTECTION TO ALL CULVERTS, INLETS, CANALS, AND
SUB-SURFACE DRAINS IN THE PROJECT VICINITY.
5. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
WORK RESTRICTIONS
1. WORK SHALL BE GENERALLY PERFORMED FROM 7:30 A.M. TO 4:00 P.M. MONDAY THROUGH
FRIDAY. TEN (10) HOUR WORK DAYS MAY BE ALLOWED WITH WRITTEN APPROVAL FROM THE
CONTRACTING OFFICER. WEEKEND AND HOLIDAY WORK SHALL BE AVOIDED AND WILL ONLY
BE ALLOWED WITH WRITTEN APPROVAL FROM THE CONTRACTING OFFICER.
2. SEE SPECIFICATIONS FOR ADDITIONAL WORK RESTRICTIONS AND REQUIREMENTS.
PROJECT STAGING AND COORDINATION
1. CONTRACTOR TO COORDINATE WITH COR FOR FINAL LOCATION OF LAY DOWN AND STAGING
YARD. PRIOR TO FENCING AREA OFF.
2. STAGING AREA SHALL BE FENCED AND SECURED AT ALL TIMES.
3. CONTRACTOR IS RESPONSIBLE FOR THE SECURITY OF THE YARD. TO ENSURE THE SAFETY OF
THE PUBLIC AND THE SECURITY OF THE SITE THE CONTRACTOR SHALL NOTIFY THE COR IF
ANY INCIDENTS OCCUR ON SITE. INCLUDING THEFT AND HEALTH SAFETY.
4. CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH ALL TRADES TO PREVENT UNFORESEEN
CONFLICTS BEFORE THEY BECOME AN ISSUE.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A LAYDOWN YARD TO ALLOW STAGING
OF EQUIPMENT PRIOR TO DELIVERY TO SITE.
6. PARKING AT SITE IS LIMITED AND CONTRACTOR TO ACCOUNT FOR ALL OFF SITE PARKING FOR
ALL EMPLOYEES DURING CONSTRUCTION PERIOD.
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 42216
CHRISTIA N GELLERT
/05
/20 24 1
2:3 4 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\G
EN
\G 0.1
G
EN
ER
AL
N
OT
ES
.D
W G
GENERAL NOTESG0.1
2 44
6-4-2024
UNLOADING ACCESS
SITE
PORTABLE TOILETS LOCATION
FREEDOM LN
C O
N C
O R
D
ST
AQUARIUM WHARF
LIBERTY W
AY
340 CONCORD ST
PIER EAST
PIER WEST
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 42216
CHRIST IA N GELLERT
/06
/20 24 0
6:4 2 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\G
EN
\G 0.2
S
IT
E
MA
P
- C
.D W
G
SITE MAPG0.2
3 44
030' 30' 60'
SCALE OF FEET
4' -6
M
IN
4' (3
'-6 " M
IN
3' M
IN
'-6
19'-2"
1'-6"
MIN.
PRE-MANUFACTURED INDUSTRIAL LOUVER 653 X PDC 6"
HURRICANE LOUVER 6063-T6 ALUMINUM EXTRUDED MIN
0.81" OR EQUAL. LOUVER SHALL BE 84" OVERALL
HEIGHT. CONNECT TO 4x4 POSTS PER
MANUFACTURER'S REQUIREMENTS.
ALUMINUM 4x4 POST W/9x9 BASE PLATE.
4'
TYP.
CHILLER
SLOPE
1%
S1.0
9"
3' 1'
3" (T
YP
.) 6" (MIN. )
3" (TYP.)
24"
MATCH SLAB
REINFORCEMENT FOR SIZE
AND SPACING
6" OF 3/4" Ø GRAVEL
COMPACTED TO 95%
PROCTOR
FILL COMPACTED TO 95% PROCTOR
GEOTEXTILE FABRIC BETWEEN
FILL AND EXISTING SUBGRADE
PER PLAN
UNDISTURBED EARTH
FINISHED
GRADE
/06
/20 24 0
7:2 0 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\A
RC
H\ S1
.0
PI
ER
W
ES
T
AS
-B
UI
LT
.D W
G
PIER WEST STRUCTURAL
PLANS1.0
4 44
04 4 8
1/4" = 1'-0"
SCALE OF INCHES
2 PIER WEST STRUCTURAL PLAN
S1.0 SCALE: 1/4" = 1'
SHEET NOTE:
1. IF EXPANSIVE OR INORGANIC MATERIALS ARE ENCOUNTERED DURING EXCAVATION, REPLACE WITH A MINIMUM OF 12 INCHES OF COMPACTIBLE SOIL BELOW FOOTING INSTEAD OF 6 INCHES AS SHOWN.
COMPACTIBLE SOIL WILL CONSIST OF 3/4 INCH GRAVEL COMPACTED TO 95%.
2. SEE S5.0 FOR SPECIFICATIONS ON CONCRETE, ALUMINUM, AND REINFORCEMENT.
KEY PLAN
WEST EAST
3'-0" ABOVE
FINISH GRADE
1 EQUIPMENT PAD X-SECTION
S1.0 SCALE: NTS
NOTE
REINFORCEMENT PLACED IN
MIDDLE OF TOP SLAB RUNNING
BOTH WAYS SHALL BE:
#4 @ 6" O.C. OR
#5 @ 9" O.C. OR
#6 @ 12" O.C.
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
JOSEPH EIXENBERGER
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 39592
2"
PRE-MANUFACTURED
HINGED PANEL SECTION
S5.0
6-14-2024
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
IT ROOM / GIFT SHOP STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
IT ROOM / GIFT SHOP STORAGE
AutoCAD SHX Text
STORAGE ROOM
AutoCAD SHX Text
CONCESSIONAIRE STORAGE
STORAGE ROOM
NEW DOUBLE DOOR DEMO EXISTING
DOOR
/06
/20 24 0
6:1 7 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\A
RC
H\ S1
.1
FI
RS
T
FL
OO
R
EA
ST
.D
W G
FIRST FLOOR EAST
STRUCTURAL PLANS1.1
5 44
04 4 8
1/4" = 1'-0"
SCALE OF INCHES
1 FIRST FLOOR EAST STRUCTURAL PLAN (PIER EAST)
S1.1 SCALE: 1/4" = 1'
KEY PLAN
WEST EAST
KEYNOTES: #
1. INSTALL SOLID CORE WOOD DOOR MATCHING
EXISTING DOOR. DOOR TO BE PROVIDED
WITH DEAD BOLT LATCH ON ONE DOOR AND
KEYED OPERATOR MATCHING DOOR
HARDWARE IN PLACE ON EXISTING DOOR.
2. POSITION DOOR TO ALLOW CLEAR ACCESS
TO ENTIRE ELECTRICAL PANEL.
3. DEMO DOOR AND PORTION OF WALL
REQUIRED FOR REPLACEMENT OF NEW
DOUBLE DOOR.
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
JOSEPH EIXENBERGER
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 39592
6-14-2024
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
GIFT SHOP
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
ELECT CHASE
AutoCAD SHX Text
PLUMBING CHASE
AutoCAD SHX Text
UPPER DECK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
TICKET BOOTH
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
MAINTENANCE OFFICE
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
GIFT SHOP
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
ELECT CHASE
AutoCAD SHX Text
PLUMBING CHASE
AutoCAD SHX Text
ENTRANCE
AutoCAD SHX Text
ELEVATOR MACH RM
UPPER DECK
F
D
C
3 4 5 6 7 98 10 11 12
F
D
C
/05
/20 24 1
3:2 7 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\A
RC
H\ S1
.2
SE
CO
ND
F
LO
OR
.D
W G
SECOND FLOOR
STRUCTURAL PLANS1.2
6 44
04 4 8
1/4" = 1'-0"
SCALE OF INCHES
2 SECOND FLOOR STRUCTURAL PLAN (PIER WEST)
S1.2 SCALE: 1/4" = 1'
DEMO EXISTING WALL
NEW WALL
DEMO EXISTING WALL
NEW WALL
KEY PLAN WEST
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
JOSEPH EIXENBERGER
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 39592
KEYNOTES: #
1. DEMO EXISTING PLENUM WALL AND ACCESS
DOOR.
2. INSTALL NEW SHEET METAL BLANK OFF
PANEL. PAINT OUTSIDE FLAT BLACK AND
INSTALL 2x6 METAL STUD WALL WITH R22
INSULATION PER DETAIL 1/S1.2.
1 WALL SECTION
S1.2 SCALE: NTS
(E)WALL (E)STEEL STRUCTURE
(E)GYP ROCK
COLD FORMED
STEEL TOP PLATE
1/2" TYP.
GYPSUM ROCK
COLD FORMED
(E)LOUVER
INSTALL WATER
BARRIER
6" STEEL STUD
@ 24' O.C.
INSTALL SHEET
METAL CAP PAINTED
FLAT BLACK. SEAL
WATER-TIGHT TO
LOUVER
INSULATE WALL
CAVITY W/R22
INSULATION
2S1.2
S1.2
COLD FORMED
STEEL BOTTOM
PLATE
6-14-2024
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
ELEVATOR LOBBY
AutoCAD SHX Text
UNISEX RESTROOM
AutoCAD SHX Text
CONFERENCE ROOM
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
OPEN TO BELOW
AutoCAD SHX Text
OPEN TO BELOW
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
ELEVATOR LOBBY
AutoCAD SHX Text
UNISEX RESTROOM
AutoCAD SHX Text
CONFERENCE ROOM
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
OPEN TO BELOW
OPEN TO BELOW
9" 1"'1
9" 7"
4"x4"x1/2" ALUMINUM POST
EQUIPMENT FOUNDATION
6"'
NYLON SHOULDER WASHER
4" Ø HEADED HEX BOLT
1.
" 80 MIL EPDM SHEET
CENTERED ON
POST SIDE3 5/16
CENTERED ON
POST SIDE
35/16
CENTERED ON
POST SIDE 35/16
CENTERED ON
POST SIDE 5/16 3
1/4" ALUMINUM PLATE
/06
/20 24 0
6:2 0 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\A
RC
H\ S5
.0
DE
TA
ILS
.D W
G
DETAILSS5.0
7 44
1 DETAIL
S5.0 SCALE: NTS
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
JOSEPH EIXENBERGER
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 39592
2 DETAIL
S5.0 SCALE: NTS
CAST-IN-PLACE CONCRETE
1. ALL CONCRETE WORK SHALL CONFORM TO THE STANDARDS
OF THE AMERIAN CONCRETE INSTITUTE, ACI 301
“SPECIFICATIONS FOR STRUCTURAL CONCRETE” AND ACI
318 “BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE”, WITH MODIFICATIONS AS NOTED IN THE
CONTRACT DOCUMENTS.
2. CONCRETE SHALL ATTAIN THE FOLLWING MINIMUM
COMPRESSIVE STRENGTH AT 28-DAY (f'c) UNLESSS NOTED
OTHERWISE:
A. CHILLER PAD: 5000 PSI, NORMALWEIGHT.
3. UNLESS NOTED OTHERWISE HEREIN, CONCRETE IS
ASSIGNED TO EXPOSRE CLASSES F0, SO, PO, AND C2, AS
DEFINIED IN ACI 318.
4. PORTLAND CEMENT SHALL CONFORM TO ASTM C150, TYPE I
OR TYPE II.
5. AGGREGATES FOR NORMAL WEIGHT CONCRETE SHALL
CONFORM TO ASTM C33. NORMAL WEIGHT CONCRETE
SHALL HAVE A DRY UNIT WEIGHT OF 150 +/- PCF.
6. MAXIMUM AGGREGATE SIZE SHALL BE 3/4 INCHES, BUT NO
LARGER THAN (A) 1/5 THE NARROWEST DIMENSION
BETWEEN SIDES OF FORMS, (B) 1/3 THE DEPTH OF SLABS,
OR (C) ¾ THE MINIMUM CLEAR SPACING BETWEEN
INDIVIDUAL REINFORCING BARS OR WIRES, BUNDLES OF
BARS, INDIVIDUAL TENDONS, BUNDLED TENDONS, OR
DUCTS.
7. MAXIMUM SLUMP SHALL BE 4 INCHES TYPICALLY, UNLESS A
HIGH-RANGE WATER REDUCING ADMIXTURE
(SUPERPLASTICIZER) IS USED IN THE CONCRETE MIX
PROPORTIONS THEN SLUMP WILL BE LIMITED TO 6 INCHES.
8. WATER CEMENT RATIO SHALL NOT EXCEED 0.4.
9. CONCRETE MIX PROPORTIONING SHALL BE BASED ON FIELD
EXPERIENCE AND/OR TRIAL MIXTURES. SUBMIT CONCRETE
MIX PROPORTIONING DATA, INCLUDING HISTORICAL
STRENGTH RECORDS AND/OR RESULTS OF TRIAL MIXTURES,
FOR EACH TYPE AND COMPRESSIVE STRENGTH OF
CONCRETE. CONCRETE MIX PROPORTIONING SHALL BE
SIGNED AND SEALED BY A PROFESSIONAL CIVIL OR
STRUCTURAL ENGINEER LICENSED IN THE STATE OF SOUTH
CAROLINA AND SHALL BE SUBMITTED TO CONTRACTING
OFFICER REPRESENTATIVE FOR REVIEW AND APPROVAL.
10. CONCRETE MIXING SHALL CONFORM TO ASTM C94.
11. PRIOR TO PLACING CONCRETE, REINFORCING BARS,
EMBEDDED PLATES, ANCHOR BOLTS, AND OTHER
CONCRETE EMBEDMENTS SHALL BE WELL SECURED IN
POSITION.
12. CONCRETE PLACEMENT SHALL CONFORM TO ACI 304 AND
CONTRACT DOCUMENTS. INTENTIONALLY ROUGHEN ALL
PREVIOUSLY HARDENED CONCRETE SURFACES TO A FULL
AMPLITUDED OF 1/4 -INCH AGAINST WHICH FRESH
CONCRETE IS PLACED.
13. FORM EXPOSED CORNER OF COLUMNS, BEAMS AND WALLS
WITH ¾ INCH CHAMFER, UNLESS NOTED OTHERWISE.
14. CONCRETE SHALL BE MAINTAINED ABOVE 50 FAHRENHEIT
AND IN A MOIST CONDITION FOR A MINIMUM OF 7 DAYS
AFTER PLACEMENET.
15. GROUT SHALL BE NON-SHRINK, NON-METALLIC, SHALL NOT
CONTAIN CHLORIDES, AND SHALL ATTAIN A 28-DAY
COMPRESSIVE STRENTH OF 6,000 PSI.
16. HOT WEATHER PLACEMENT SHALL BE IN ACCORDANCE WITH
ACI 305R.
17. COLD WEATHER PLACEMENT SHALL BE INACCORDANCE
WITH ACI 306R.
18. AT LOCATIONS WHERE BASEPLATES ARE TO BE PLACED THE
CONCRETE WILL TROWEL FINISHED.
19. AN 80 MIL EPDM SHEET SHALL BE PLACED BETWEEN THE
ALUMINUM BASEPLATE AND THE CONCRETE.
REINFORCING STELL
1. REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE
TO AMERICAN CONCRETE INSTITUTE ACI 318 “BUILDING
CODE REQUIREMENTS FOR STRUCTURAL CONCRETE” AND
CONCRETE REINFORCING STEEL INSTITUTE (CRSI)
“MANUAL OF STANDARD PRACTICE”.
2. REINFORCING STEEL SHALL CONFORM TO ASTM A615,
GRADE 60, UNLESS NOTED OTHERWISE. BARS TO BE
WELDED SHALL CONFORM TO LOW ALLOY ASTM A706.
3. BASEPLATE ANCHORS SHALL CONFORM TO ASTM F1554
GRADE 55. ANCHORS SHALL BE HOT DIPPED GALVANIZED.
A NYLON SHOULDER WASHER SHALL BE PLACED BETWEEN
THE STEEL WASHER FOR THE ANCHOR BOLT AND THE
ALUMINUM BASEPLATE INSERTED INTO THE BASEPLATE
ANCHOR HOLE. THE NYLON WASHER WILL HAVE A MINIMUM
WASHER THICKNESS OF ¼ INCH AND A BUSH LENGTH
EQUAL TO THE BASEPLATE THICKNESS.
4. REINFORCING STEEL SHALL BE SPLICED AS SHOWN ON
THE DRAWINGS. IF NOT SHOWN, LOCATE SPLICES IN AREAS
OF MINIMUM STRESS. LAP (SPLICE LENGTHS ARE AS
INDICATED ON THE DRAWINGS.
5. PROVIDE THE FOLLOWING CONRETE COVERAGE FOR
REINFORCING STEEL PLACED IN CAST IN-PLACE
CONCRETE:
A. CONCRETE CAST AGAINST AND PERMANETLY EXPOSED
TO EARTH: 3 INCHES
B. CONCRETE EXPOSED TO EARTH OR WEATHER: NO. 6-NO.
18: 2 INCHES. NO. 5 BARS, W31 OR D31 WIRE, AND
SMALLER 1.5 INCHES.
C. CONCRETE NOT EXPOSED TO WEATHR OR IN CONTACT
WITH GROUND: NO. 14 AND NO 18 BARS: 1.5 INCHES. NO.
11 BARS AND SMALLER: 1 INCH.
D. SLAB ON GRADE: MID-HEIGHT OF SLABS.
6. USE PLASTIC OR PLASTIC COATED SPACERS AND CHAIRS IF
RESTING ON EXPOSED CONCRETE SURFACES.
7. REINFORCING STEEL BENDS SHALL BE MADE COLD.
RE-BENDING OF PREVIUOLSY BENT REINFORCING IS NOT
PERMITTED.
8. ALL REINFORCING STEEL SHALL BE SECURELY HELD IN
PLACE WHILE PLACING CONCRETE. IF REQUIRED,
ADDITIONAL BARS OR STIRRUPS SHALL BE PROVIDED BY
THE CONTRACTOR TO FURNISH SUPPORT FOR ALL
REINFORCING.
9. ALL REINFORCING STEEL SHALL BE MARKED SO THEIR
IDENTIFICAITON CAN BE MADE WHEN FINAL INSPECTION IS
CONDUCTED.
10. NUTS SHALL CONFORM TO ASTM A 563 GRADE A. WASHERS
SHALL CONFORM TO ASTM 436. BOLT HOLE DIAMETER
SHALL CONFORM TO AISC TABLE 14-2. BOLTS WILL BE
SNUG TIGHTENED.
ALUMINUM
1. ALUMINUM TUBING AND PLATES SHALL CONFORM TO 5083
O ALLOY.
2. Aluminum tubing and plates shall conform to 5083 O Alloy.
3. WELDING SHALL CONFORM TO LATEST EDITION OF
ANSI/AWS D1.1
A. WELDING PROCESS SHALL BE ARC WELDING USING
5356 FILLER.
B. WELDERS SHALL BE CERTIFIED TO CONFORM WITH
AWS STANDARDS AND APPROVED BY THE GOVERNING
CODE AUTHORITY.
C. SHOP WELDING SHALL BE PERFORMED ON THE
PREMISES OF AN APPROVED FABRICATOR.
D. FIELD WELD SYMBOLS NOTED ON THE DRAWINGS
SHOW ENGINEERING INTENT, BUT NO ATTEMPT HAS BEEN
MADE TO CLASSIFY ALL WELDS. AT FABRICATOR’S OPTION,
ANY WELD INDICATED AS A FIELD WELD MAY BE SHOP
WELDED AND ANY WELD INDICATES AS SHOP WELD MAY BE
FIELD WELDED.
4. WELDS SHALL BE PREQUALIFIED PER AWS D1.1.
NON-PREQUALIFIED WELDED JOINTS SHALL BE QUALIFIED
BY TEST PER AWS D1.1.
NOTE:
1. CONTRACTOR TO DRILL 14 Ø HOLE AT EACH CORNER OF THE
ALUMINUM POST AT THE BASE
2. TOP OF POST WILL BE CAPPED WITH 14" ALUMINUM PLATE WELDED
TO THE TOP OF POST WITH 316" FILLED WELD ALL AROUND.
6-14-2024
INTERNALLY LINED DUCT -
SEE NOTES OR
SPECIFICATION FOR TYPE
OF LINING TO BE
USED. DIMENSIONS
DENOTE INTERNAL FREE
AREA.
FOB
(DOUBLE LINE) RISE OR DROP ARROW
IN THE DIRECTION OF
AIRFLOW(SINGLE LINE)
FLEX DUCT
CONCENTRIC
TRANSITION
ECCENTRIC
TRANSITION -
(FOT = FLAT ON TOP,
FOB = FLAT ON
BOTTOM)
DUCTWORK OR
EQUIPMENT TO
BE DEMOLISHED(SINGLE LINE)
(SINGLE LINE)
(DOUBLE LINE)
(DOUBLE LINE)
(SINGLE LINE)
(DOUBLE LINE)
(SINGLE LINE)
(DOUBLE LINE)
(DOUBLE LINE)
(SINGLE LINE)
SYMBOL
24"x16" DUCT SIZES - FIRST
DIMENSION LISTED IS
VIEW DIMENSION(SINGLE LINE)
(DOUBLE LINE)
DESCRIPTION SYMBOL
HUMIDISTAT,
THERMOSTAT - CALLOUT
REFERENCES DEVICE,
SEE SCHEDULES. MOUNT
ALL DEVICES PER
ARCHITECTURAL
GUIDELINES.
TURN DOWN/UP FOR
VARIOUS STYLES OF
DUCTWORK
4-WAY 3-WAY
DH-01
EQUIPMENT TAG NAME
AHU-01
LINEAR SUPPLY / RETURN
POWER OR GRAVITY
ROOF INTAKE/EXHAUST
EQUIPMENT TAG
SYMBOL; SEE EQUIPMENT
SCHEDULES FOR THE
CAPACITY, TYPE, AND
QUANTITY.
CEILING SUPPLY
DIFFUSERS, SOLID
FILL REPRESENTS
BLANKED OFF AREAS.
SIDEWALL
SUPPLY/RETURN
REGISTER, DIFFUSER,
GRILLE.
CEILING RETURN GRILLE
NECK/THROAT SIZE
CFM TO BALANCE TO
NUMBER OF DIFFUSERS
DESCRIPTION
TAG NUMBER
GRILLES, REGISTERS,
DIFFUSERS - CALLOUT
CEILING EXHAUST GRILLE
FOT
SPIN-IN FITTING
RETURN
SPIN-IN FITTING
SUPPLY
8"Ø
L24"x16"
L8"Ø
8"Ø
24"x16"
8"Ø
24"x16"
DROP
RISE
24"x16"
(SINGLE LINE)
(DOUBLE LINE)
(SINGLE LINE)
(DOUBLE LINE)24"x16"
SD-1 12"Ø
500 CFM (4 TYP)
TH
DUCT MOUNTED
SMOKE DETECTOR
CONTROL AIR OR
ZONE DAMPER
BACKDRAFT DAMPER
AUTOMATIC MOTOR
OPERATED DAMPER
PARALLEL AND
OPPOSED BLADE
VOLUME DAMPER
MM
SD
(DOUBLE LINE)
(SINGLE LINE)
BDD
(DOUBLE LINE)
(SINGLE LINE)
(DOUBLE LINE)
(SINGLE LINE)
(DOUBLE LINE)
(SINGLE LINE)
(SINGLE LINE)
(DOUBLE LINE)
SEQUENTIAL EQUIPMENT
NUMBER
(SINGLE LINE)
(DOUBLE LINE)
CAP (DOUBLE LINE)
CAP (SINGLE LINE)
DUCT CAP
(SINGLE
LINE)ROUND
8"TURNUP TURN
DOWN
RECTANGLE10"x6"
TURNUP TURN
DOWN
FLAT OVAL
24"x12"
(DOUBLE
LINE)ROUND
24"Ø
RECTANGLE24"x12"
MM
BDD
SD
AHU
2-WAY
(CORNER)
2-WAY
(OPPOSED
THROW)
ACCESS DOOR (AD)
ACCESS PANEL (AP)(SINGLE LINE)
(DOUBLE LINE)
HVAC LEGEND
DIRECTION OF
AIRFLOW
SUPPLY DUCT (RISE)
RETURN DUCT (RISE)
EXHAUST DUCT (RISE)
POINT OF CONNECTION
(DOUBLE LINE)(SINGLE LINE)
FIRE DETECTOR
TURNING VANES IN
DUCTWORK
45° ENTRY TRANSITION
S
NITROUS OXIDE
MEDICAL VACUUM
MEDIUM PRESSURE CONDENSATE
MEDIUM PRESSURE STEAM
LOW PRESSURE CONDENSATE
LOW PRESSURE STEAM
HIGH PRESSURE CONDENSATE
HIGH PRESSURE STEAM
LIQUEFIED PETROLEUM GAS
ROOF DRAIN LEADER
POTABLE WATER
POTABLE HOT WATER SUPPLY
POTABLE HOT WATER RETURN
OVERFLOW DRAIN LEADER
NON POTABLE WATER
HEATING WATER SUPPLY
HEATING WATER RETURN
DOMESTIC HOT WATER
RDL
PHWS
PW
PHWR
ODL
NG
NPW
NATURAL GAS
N2
N20
MPS
MV
MPC
MA
LPS
LPC
NITROGEN
MEDICAL AIR
LPG
HWS
HWR
HW
HPS
HPC
PRESSURE REDUCING VALVE
BALL VALVE (NORMALLY OPEN)
BALL VALVE (NORMALLY CLOSED)
THREE WAY CONTROL VALVE
FLEXIBLE PUMP CONNECTOR
N.C.
STRAINER
SOLENOID VALVE
UNION
PRESSURE RELIEF VALVE
WATER HAMMER ARRESTOR
PRESSURE REGULATOR
AGA RATED GAS VALVE
GATE VALVE
CONTROL VALVE
THERMO WELL
RP
REDUCED PRESSURE
BACK FLOW ASSY.
CHECK VALVE
PIPE CAP
WALL CLEAN-OUT
FLOOR CLEAN-OUT
GRADE CLEAN-OUT
DOUBLE CHECK ASSEMBLY
DIRECTION OF FLOW
PIPE DROP
PIPE RISE
PIPE RISE
VENT THRU ROOF
REDUCER
PIPE DROP
OUTSIDE STEM AND YOKE
PLUG VALVE
RECIRC PUMP
CARBON DIOXIDE
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
CLEAN DRY AIR
CONDENSATE DRAIN
GREASE WASTE
DOMESTIC COLD WATER
CHILLED WATER SUPPLY
CHILLED WATER RETURN
COMPRESSED AIR
GW
CHWS
CW
DEMO ITEMS
CHWR
CWS
CWR
CO2
COND
CDA
CA
DOMESTIC HOT WATER RECIRC.HWC
INSTRUMENT AIR
INDIRECT WASTEIDW
IA
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
INLINE TEMPERATURE GAUGE
PLUMBING/PIPE LEGEND
M
FS
FLOW VALVE
GAS METER
GLOBE VALVE
FLOW SWITCH
FLOOR SINK
BALANCE VALVE
FM FLOW METER
DIAPHRAGM VALVE
DOWNSPOUT NOZZLE
FLOOR DRAIN ROUND OR
SQUARE
TEMPERATURE CONTROL
VALVE
AUTOMATIC AIR VENT
VACUUM RELIEF VALVE
MANUAL AIR VENT
VERTICAL VALVE
ROOF DRAIN
OVERFLOW DRAIN
EXPANSION TANK
POINT OF CONNECTION
TO EXISTING
HOT GLYCOL RETURN
HOT GLYCOL SUPPLYHGS
HGR
HE HELIUM
BREAK LINE
QUICK DISCONNECT
IN-LINE PUMP
STEAM VALVE
BUTTERFLY VALVE
IN-LINE PUMP
TEMPERED WATER SUPPLY
TEMPERED WATER RETURN
TEMPERED POTABLE WATER
SANITARY SEWER
V
TWR
TWS
SS
TPW
VENT
HOSE BIB
CIRCUIT SETTER
THERMOMETER
PRESSURE GAUGE
SD STORM DRAIN
(SINGLE LINE)
SFF S (DOUBLE LINE)
F = FIRE DAMPER
S = SMOKE DAMPER
F & S = FIRE AND SMOKE
DAMPER
SEE NOTES AND/OR
SPECIFICATION FOR
EXACT RATING AND
MODEL NUMBERS
@ AT
Ø DIAMETER/PHASE
</L ANGLE
# NUMBER/POUND
° DEGREE
(D) DEPTH
(E) EXISTING
(F) FUTURE
(L) LENGTH
(N) NEW
(W) WIDTH
ABS ACRYLONITRILE BUTADIENE
STYRENE
ABV ABOVE
ACCU AIR COOLED CONDENSING
UNIT
ACOUST ACOUSTICAL
ACP ACOUSTICAL PANEL
ACT ACOUSTICAL TILE
AD AIR DROP
ADA AMERICAN DISABILITIES ACT
ADJ ADJUSTABLE
AF AIR FOIL
AFC BOVE FINISHED CEILING
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
AFS ABOVE FINISH SLAB
AFUE AMERICAN FUEL
UTILIZATION EFFICIENCY
AHU AIR HANDLING UNIT
ALT ALTERNATE
AL ALUMINUM
AMB AMBIENT
AMP AMPERES
ANOD ANODIZED
ANSI AMERICAN NATIONAL
STANDARDS INSTITUTE
AP AIR PRESSURE
APD AIR PRESSURE DROP
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASHRAE AMERICAN SOCIETY OF
HEATING REFRIGERATION, AND AIR
CONDITIONING ENGINEERS
ASTM AMERICAN SOCIETY OF
TESTING MATERIALS
AUTO AUTOMATIC
AUX AUXILIARY
ASTM AMERICAN SOCIETY OF
TESTING MATERIALS
AUTO AUTOMATIC
AUX AUXILIARY
BDD BACK DRAFT DAMPER
BFF BELOW FINISH FLOOR
BFS BELOW FINISH SLAB
BG BELOW GRADE
BHP BRAKE HORSEPOWER
BI BACKWARD INCLINED
BLDG BUILDING
BOD BOTTOM OF DUCT
BOP BOTTOM OF PIPE
BOS BOTTOM OF STEEL
BOT BOTTOM
BRD BOARD
BRG BEARING
BTU BRITISH THERMAL UNIT
CA COMBUSTION AIR
CB CATCH BASIN
CAP CAPACITY
CD CONDENSATE DRAIN
CDA CLEAN DRY AIR
CF CUBIC FEET
CFF CAP FOR FUTURE
CFCI CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
CFF CAP FOR FUTURE
CFM CUBIC FEET PER MINUTE
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CI CAST IRON
CL CENTER LINE
CLG CEILING
CLK CAULK(ING)
CLR CLEAR
CNT CENTER
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
COND CONDENSATE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS/CONTINUATION
CONTR CONTRACTOR
COTG CLEANOUT TO GRADE
CTC CENTER TO CENTER
CFF CAP FOR FUTURE
CLK CAULK(ING)
CLR CLEAR
CV VALVE COEFFICIENT
CW DOMESTIC COLD WATER
CWFR CHEMICAL WATER FEED RETURN
CWFS CHEMICAL WATER FEED SUPPLY
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
CW/ COORDINATE WITH
CX CONNECT TO EXISTING
DB DECIBEL
DBL DOUBLE
DB DRY BULB TEMPERATURE
DEPT DEPARTMENT
DET DETAIL
DIM DIMENSION
DISCH DISCHARGE
DN DOWN
DS DOWNSPOUT
DSN DOWNSPOUT NOZZLE
DSP DRY STANDPIPE
DWG DRAWING
DEG DEGREE
E EAST
EA EACH
EAT ENTERING AIR TEMPERATURE
EF EXHAUST FAN
EFF EFFICIENCY
EG EXHAUST GRILLE
ELECT ELECTRICAL
ELEV ELEVATION
EMERG EMERGENCY
ENCL ENCLOSED/ENCLOSURE
ENT ENTERING
EQ EQUAL
EQUIP EQUIPMENT
ESP EXTERNAL STATIC PRESSURE
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EXP EXPANSION
EXT EXTERIOR
EXIST EXISTING
F FIRE SERVICE
FA FIRE ALARM
FAU FURNACE AIR UNIT
FC FORWARD CURVED
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FH FIRE HYDRANT
FIN FINISH
FINS/IN FINS PER INCH
FLA FULL LOAD AMPS
FLASH FLASHING
FLR FLOOR(ING)
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
FPM FEET PER MINUTE
FRPF FIREPROOF
FS FLOOR SINK
FT FEET/FOOT
FURR FURRING
F FIRE SERVICE
FDC FIRE DEPARTMENT CONNECTION
FS FLOOR SINK
FUT FUTURE
GA GAUGE OR GAGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GCO GRADE CLEANOUT
GE GENERAL EXHAUST
GND GROUND
GPM GALLONS PER MINUTE
GSM GALVANIZED SHEET METAL
GW GREASE WASTE
H HUMIDIFIER
H20 WATER
HB HOSE BIB
HCP HANDICAP
HD HEAD
HDWR HARDWARE
HGR HOT GLYCOL RETURN
HGS HOT GLYCOL SUPPLY
HORIZ HORIZONTAL
HP HORSEPOWER
HPC HIGH PRESSURE CONDENSATE
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HTG HEATING
HVAC HEATING, VENTILATING, AND AIR
CONDITIONING
HW POTABLE HOT WATER SUPPLY
HWC DOMESTIC HOT WATER RECIRC.
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
IA INSTRUMENT AIR
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IDW INDIRECT WASTE
IE INVERT ELEVATION
IGV INLET GUIDE VANE(S)
IMC INTERNATIONAL MECHANICAL CODE
IN INCH
IND INDIRECT
INSUL INSULATION
INT INTERIOR
IPC INTERNATIONAL PLUMBING CODE
J-BOX JUNCTION BOX
JST JOIST
KW KILOWATT
KWH KILOWATT HOUR
L/S LITERS PER SECOND
L LINED
LA LAVATORY
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LF LINEAL FEET/FOOT
LPC LOW PRESSURE CONDENSATE
LPG LIQUEFIED PETROLEUM GAS
LRA LOCKED ROTOR AMP
LWT LEAVING WATER TEMPERATURE
M METER
MAT MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFG MANUFACTURER
MHT MALE HOSE THREAD
MIN MINIMUM
MISC MISCELLANEOUS
MM MILLIMETER
MO MOTOR OPERATED
MOCP MAX OVERLOAD CURRENT
PROTECTION
MPC MEDIUM PRESSURE CONDENSATE
MPS MEDIUM PRESSURE STEAM
MTD MOUNTED
MTG MOUNTING
MTL METAL
MUA MAKE-UP AIR/ MAKE-UP AIR UNIT
MC MECHANICAL CONTRACTOR
MSG MANUFACTURED STANDARD GAUGE
N NORTH
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NEC NATIONAL ELECTRIC CODE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM NOMINAL
NPW NON-POTABLE WATER
NTS NOT TO SCALE
NUM NUMBER
OBD OPPOSED BLADE DAMPER
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED, CONTRACTOR
INSTALLED
OFOI OWNER FURNISHED, OWNER
INSTALLED
OH OVERHEAD
OSA OUTSIDE AIR
OS&Y OUTSIDE STEM & YOKE
OZ OUNCE
ODL OVERFLOW DRAIN LEADER
P PRESSURE
PD PRESSURE DROP OR DIFFERENCE
PH PHASE(S)
PHWR POTABLE HOT WATER RETURN
PHWS POTABLE HOT WATER SUPPLY
PIV POST INDICATOR VALVE
PLBG PLUMBING
POC POINT OF CONNECTION
PRV PRESSURE REDUCING VALVE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
PW POTABLE WATER
P/T PRESSURE/TEMPERATURE
R RISER
RA RETURN AIR
RAD RADIUS
RBI RE-HEAT BOX
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
RE: REFERENCE
REFL REFLECTED
REL RELOCATE
REM REMOVE
REINF REINFORCE
RET RETURN
RF RECIRCULATION FAN
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RO REVERSE OSMOSIS
RPBP REDUCED PRESSURE BACKFLOW
PREVENTER
RPM REVOLUTIONS PER MINUTE
RTU ROOFTOP UNIT
REFG REFRIGERATION/REFRIGERANT
REQD REQUIRED
RFLD REFLECTED
RIO ROUGH IN ONLY
RPM REVOLUTIONS PER MINUTE
S SOUTH
SA SUPPLY AIR
SCHED SCHEDULE
SD SUPPLY DIFFUSER
SECT SECTION
SEER SEASONAL ENGINEERING
EFFICIENCY RATING
SEN SENSIBLE
SER SERIES
SF SQUARE FOOT
SH SENSIBLE HEAT
SIM SIMILAR
SL SUPPLY LOUVER
SMACNA SHEET METAL AND
AIR CONDITIONING
CONTRACTORS
NATIONAL ASSOCIATION
SOV SHUT OFF VALVE
SP STATIC PRESSURE
SPEC SPECIFICATION
SQ SQUARE
SS SANITARY SEWER
SST STAINLESS STEEL
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUP SUPPLY
SUSP SUSPENDED
SYS SYSTEM
SHT SHEET
TA TRANSFER AIR
TD TEMPERATURE DIFFERENCE
TEMP TEMPERATURE/TEMPERED/
TEMPORARY
TOD TOP OF DUCT
TOS TOP OF STEEL
TPW TEMPERED POTABLE WATER
TSP TOTAL STATIC PRESSURE
T-STAT TEMPERATURE STAT
TV TURNING VANE(S)
TWR TEMPERED WATER RETURN
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
U URINAL
UBC UNIFORM BUILDING CODE
UFC UNIFORM FIRE CODE
UG UNDERGROUND
UL UNDERWRITERS LABORATORY
UMC UNIFORM MECHANICAL CODE
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UPC UNIFORM PLUMBING CODE
V VOLT
VA VALVE
VAC VACUUM
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VEL VELOCITY
VENT VENTILATION
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
VRV VACUUM RELIEF VALVE
VTR VENT THROUGH ROOF
VVT VARIABLE VOLUME TERMINAL
VIF VERIFY IN FIELD
W WEST
W/ WITH
W/O WITHOUT
WB WET BULB TEMPERATURE
WC WATER CLOSET
WCO WALL CLEANOUT
WH WATER HEATER
WP WATERPROOF
WT WEIGHT
ZD ZONE DAMPER
ABBREVIATIONS
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 42216
CHRIST IA N GELLERT
/06
/20 24 0
7:2 8 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\M
EC
H\ M0
.0
ME
CH
AN
IC
AL
LE
GE
ND
.D
W G
MECHANICAL LEGEND &
ABBREVIATIONSM0.0
8 44
EA
ST
W
ES
T
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 42216
CHRIST IA N GELLERT
/05
/20 24 1
2:4 9 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\M
EC
H\ M1
.0
DE
MO
P
IE
R
W
ES
T
PL
AN
.D
W G
PIER WEST HVAC DEMO
PLANM1.0
9 44
1 PIER WEST HVAC DEMO PLAN
M1.0 SCALE: 1/4" = 1'
KEYNOTES: #
1. DEMO MINI SPLIT CONDENSING UNIT
MOUNTED HIGH ON WALL (LEAVE BRACKETS
AND SUPPORTING HARDWARE FOR
REMOUNTING).
2. DEMO MINI SPLIT WALL CASSETTE (LEAVE
BRACKET AND NON PROPRIETARY
MOUNTING HARDWARE IN PLACE).
04 4 8
1/4" = 1'-0"
SCALE OF FEET
KEY PLAN
WEST EAST
6-4-2024
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
IT ROOM / GIFT SHOP STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
IT ROOM / GIFT SHOP STORAGE
AutoCAD SHX Text
STORAGE ROOM
AutoCAD SHX Text
CONCESSIONAIRE STORAGE
DEMOLISH
DEHUMIDIFIER
DEMOLISH
EXHAUST FAN
W
ES
T
EA
ST
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 42216
CHRIST IA N GELLERT
/05
/20 24 1
2:4 9 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\M
EC
H\ M1
.1
DE
MO
P
IE
R
EA
ST
P
LA
N.
DW
G
PIER EAST HVAC DEMO
PLANM1.1
10 44
1 PIER EAST HVAC DEMO PLAN
M1.1 SCALE: 1/4" = 1'
KEYNOTES:
1. DEMOLISH EXHAUST FAN AND MAINTAIN
MOUNTING HARDWARE IN PLACE.
2. DEMOLISH DEHUMIDIFICATION UNIT AND
MAINTAIN MOUNTING HARDWARE IN PLACE.
04 4 8
1/4" = 1'-0"
SCALE OF FEET
KEY PLAN
WEST EAST
6-4-2024
AutoCAD SHX Text
STORAGE ROOM
AutoCAD SHX Text
CONCESSIONAIRE STORAGE
AutoCAD SHX Text
STORAGE ROOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
IT ROOM / GIFT SHOP STORAGE
AutoCAD SHX Text
STORAGE ROOM
AutoCAD SHX Text
CONCESSIONAIRE STORAGE
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
LIC
EN
SE
DPROFESSIONALENGINEERNo. 42216
CHRISTIA N GELLERT
/06
/20 24 0
6:2 0 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\M
EC
H\ M1
.2
DE
MO
LI
BE
RT
Y
SQ
F
IR
ST
F
LO
OR
W
ES
T
PL
AN
.D
W G
FIRST FLOOR WEST HVAC
DEMO PLANM1.2
11 44
1 1ST FLOOR WEST HVAC DEMO PLAN
M1.2 SCALE: 1/4" = 1'
KEYNOTES: #
1. DEMOLISH FAN COIL UNIT INCLUDING ALL
DUCTWORK, GRILLES, AND REGISTERS.
RETAIN ALL MOUNTING HANGERS, POINTS
AND COMPONENTS REQUIRED FOR THE
REPLACEMENT OF DUCTWORK.
2. RETAIN AND PROTECT RETURN DUCT IN
PLACE. CLEAN ALL DUCTWORK GRILLES AND
REGISTERS.
3. RETAIN AND PROTECT SUPPLY DUCTWORK
IN PLACE. CLEAN ALL DUCT GRILLES AND
REGISTERS. CONTRACTOR TO EVALUATE
EXISTING DUCTWORK TO REMAIN FOR RUST
OR DAMAGE, AND NOTIFY COR IF THE
DUCTWORK SHOWS ANY DAMAGE. COR TO
DETERMINE IF DAMAGED DUCTWORK IS TO
BE REMOVED.
4. DEMOLISH THIS SECTION OF DUCT AND CAP
TAKE-OFF ACTIVE DUCT. PROVIDE 18 GAUGE
SHEET METAL CAP, FASTENED TO EXISTING
DUCT AND REPAIR INSULATION TO SEAL
UNPROTECTED DUCT.
5. REMOVE THERMOSTAT AND PREPARE FOR
NEW THERMOSTAT MATCHING NEW CONTROL
SYSTEM.
04 4 8
1/4" = 1'-0"
SCALE OF FEET
KEY PLAN
WEST EAST
4 4
UP TO FLOOR ABOVE 2
6-4-2024
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
TICKET BOOTH
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
MAINTENANCE OFFICE
AutoCAD SHX Text
ENTRANCE
AutoCAD SHX Text
ELEVATOR MACH RM
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
WEST EAST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
TICKET BOOTH
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
MAINTENANCE OFFICE
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
GIFT SHOP
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
ELECT CHASE
AutoCAD SHX Text
PLUMBING CHASE
AutoCAD SHX Text
ENTRANCE
AutoCAD SHX Text
ELEVATOR MACH RM
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 42216
CHRIST IA N GELLERT
/05
/20 24 1
2:4 9 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\M
EC
H\ M1
.3
DE
MO
LI
BE
RT
Y
SQ
F
IR
ST
F
LO
OR
W
ES
T
PI
PI
NG
P
LA
N.
DW
G
FIRST FLOOR WEST PIPING
DEMO PLANM1.3
12 44
1 1ST FLOOR WEST PIPING DEMO PLAN
M1.3 SCALE: 1/4" = 1'
KEYNOTES: #
1. DEMOLISH EXISTING PIPING HANGERS AND
MOUNTING POINTS FOR PIPING SERVING ALL
FAN COILS IN THIS FLOOR.
2. DEMOLISH ANY ABANDONED PIPING FROM
PREVIOUS PROJECTS. CONTRACTOR TO
VERIFY THAT PIPING AND EQUIPMENT IS NO
LONGER IN USE PRIOR TO DEMOLITION.
UP TO FLOOR ABOVE
04 4 8
1/4" = 1'-0"
SCALE OF FEET
KEY PLAN
WEST EAST
6-4-2024
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
TICKET BOOTH
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
MAINTENANCE OFFICE
AutoCAD SHX Text
ENTRANCE
AutoCAD SHX Text
ELEVATOR MACH RM
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
WEST EAST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
TICKET BOOTH
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
MAINTENANCE OFFICE
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
GIFT SHOP
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
ELECT CHASE
AutoCAD SHX Text
PLUMBING CHASE
AutoCAD SHX Text
ENTRANCE
AutoCAD SHX Text
ELEVATOR MACH RM
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 42216
CHRIST IA N GELLERT
/06
/20 24 0
6:2 2 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\M
EC
H\ M1
.4
DE
MO
LI
BE
RT
Y
SQ
F
IR
ST
F
LO
OR
E
AS
T
PL
AN
.D
W G
FIRST FLOOR EAST HVAC
DEMO PLANM1.4
13 44
M2.0
1 1ST FLOOR EAST HVAC DEMO PLAN
M1.4 SCALE: 1/4" = 1'
KEYNOTES: #
1. DEMOLISH DEHUMIDIFICATION UNIT
INCLUDING ALL DUCTWORK, RETAINING ALL
MOUNTING POINTS AND HANGER SYSTEMS
REQUIRED FOR THE NEW WORK.
2. DEMOLISH FAN COIL, DUCTWORK AND
ASSOCIATED COMPONENTS, RETAINING ALL
MOUNTING COMPONENTS REQUIRED FOR
THE NEW WORK.
3. RETAIN AND PROTECT TRANSFER DUCT
SYSTEM IN PLACE.
4. CLEAN AND PROTECT DUCT GRILLES AND
REGISTERS ASSOCIATED WITH THIS
DUCTWORK AS SHOWN.
5. RETAIN OSA DUCT IN PLACE.
6. RETAIN AND PROTECT EXHAUST DUCT
SYSTEM IN PLACE
7. RETAIN AND PROTECT LOUVER IN PLACE
04 4 8
1/4" = 1'-0"
SCALE OF FEET
KEY PLAN
WEST EAST
8. DEMOLISH EXHAUST FAN. PREPARE FOR
REPLACEMENT OF NEW FAN.
9. REMOVE THERMOSTAT AND PREPARE FOR
NEW THERMOSTAT MATCHING NEW CONTROL
SYSTEM.
KEYNOTES (CONTINUED):
4 4
2 2
6-4-2024
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
GIFT SHOP
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
ELECT CHASE
AutoCAD SHX Text
PLUMBING CHASE
AutoCAD SHX Text
UPPER DECK
AutoCAD SHX Text T
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
AC-3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
TICKET BOOTH
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
MAINTENANCE OFFICE
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
GIFT SHOP
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
ELECT CHASE
AutoCAD SHX Text
PLUMBING CHASE
AutoCAD SHX Text
ENTRANCE
AutoCAD SHX Text
ELEVATOR MACH RM
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 42216
CHRIST IA N GELLERT
/05
/20 24 1
2:4 8 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\M
EC
H\ M1
.5
DE
MO
LI
BE
RT
Y
SQ
F
IR
ST
F
LO
OR
E
AS
T
PI
PI
NG
P
LA
N.
DW
G
FIRST FLOOR EAST PIPING
DEMO PLANM1.5
14 44
M2.0
1 1ST FLOOR EAST PIPING DEMO PLAN
M1.5 SCALE: 1/4" = 1'
KEYNOTES: #
1. DEMOLISH HEATING & CHILLED WATERLINES
AS SHOWN FROM THIS POINT TO UNIT.
RETAIN MOUNTING AND SUPPORT SYSTEMS
IN PLACE FOR REPLACEMENT SYSTEM.
04 4 8
1/4" = 1'-0"
SCALE OF FEET
KEY PLAN
WEST EAST
6-4-2024
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
GIFT SHOP
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
ELECT CHASE
AutoCAD SHX Text
PLUMBING CHASE
AutoCAD SHX Text
UPPER DECK
AutoCAD SHX Text T
AutoCAD SHX Text
AC-3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
TICKET BOOTH
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
MAINTENANCE OFFICE
AutoCAD SHX Text
EXHIBIT HALL
AutoCAD SHX Text
GIFT SHOP
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
ELECT CHASE
AutoCAD SHX Text
PLUMBING CHASE
AutoCAD SHX Text
ENTRANCE
AutoCAD SHX Text
ELEVATOR MACH RM
T
AHU-4
T AC-1
30x21
14.5x21
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
REPLACE HVAC SYSTEMS AT
LIBERTY SQUARE VISITOR EDUCATION CENTER
FORT SUMTER AND FORT MOULTRIE NATIONAL HISTORICAL PARK
I. BROWN
M. NGUY
B. BROOKE
6/2024
192499
316098B
SO
UTH CAROLINA
LIC
EN
SE
DPR
OFESSIONALENGINEERNo. 42216
CHRIST IA N GELLERT
/06
/20 24 0
6:2 6 K
EV
IN
F
LO
RE
S G
:\C
LIE
NT
S\
NP
S\
FO
SU
\LI
BE
RT
Y
SQ
UA
RE
H
VA
C\
DR
AW
IN
GS
\M
EC
H\ M1
.6
DE
MO
LI
BE
RT
Y
SQ
S
EC
ON
D
FL
OO
R
PL
AN
.D
W G
SECOND FLOOR HVAC
DEMO PLANM1.6
15 44
M2.1
M2.2
1 2ND FLOOR HVAC DEMO PLAN
M1.6 SCALE: 1/4" = 1'
KEYNOTES: #
1. DEMOLISH ENERGY RECOVERY DEHUMIDIFIER SYSTEM INCLUDING ALL
DUCTWORK SUPPORTING POINTS AND HARDWARE.
2. DEMOLISH OSA SYSTEM INCLUDING EQUIPMENT AND DUCTWORK
LEAVING MOUNTING HARDWARE, MOUNTING POINTS, AND LOUVER FOR
NEW INSTALLATION..
3. RETAIN AND PROTECT LOUVER. DEMO ALL CONNECTED DUCTWORK.
4. RETAIN EXISTING DUCTWORK FROM THIS…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .