This is a product specification document for a Chicago Faucets single ball valve (Model 909-AGVCP) related to a State University of New York at Buffalo Invitation for Bid for furnish and installation of science casework and equipment for the Biomedical Education Building Third Floor Teaching Lab renovation. The Chicago Faucets 900 Series Lab Fitting is a single ball valve designed for wall or turret mount with a laboratory nozzle featuring 10 serrations for laboratory hose attachment. The valve is rated for multiple gas services including acetylene, ammonia, argon, butane, carbon dioxide, carbon monoxide, helium, hydrogen, natural gas, methane, nitrogen, and propane at 7.25 PSI maximum operating pressure, as well as air and compressed air at 125 PSI and cold water at 125 PSI. The product includes a 5-year limited faucet warranty, lifetime limited faucet warranty, 1-year limited finish warranty, and 5-year limited mechanical warranty, and complies with ADA standards and ANSI/ICC A117.1 specifications. The valve features a 3/8" NPT male thread inlet and chrome plated construction and is certified for gas service per ANSI Z21.15/CSA 9.1 by the Canadian Standards Association.

Installation must comply with local plumbing codes, and all pipes should be flushed thoroughly before and after installation to clear debris. Maintenance requires only mild soap and warm water; abrasive cleaners, chemicals, and solvents should be avoided as they may cause surface damage. Chicago Faucets, a member of the Geberit Group and leading U.S. commercial faucet brand, manufactures the product and provides technical support at 1.800.TECTRUE or 1.847.803.5000. Product specifications are subject to change without notice as of the last revision date of November 24, 2025.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Job Name ________________________________________________

Item Number _____________________________________________

Section/Tag ______________________________________________

Model Specified ___________________________________________

Architect _________________________________________________

Engineer _________________________________________________

Contractor ________________________________________________

[ ] Submitted as Shown [ ] Submitted with Variations

Date _____________________________________________________

2100 South Clearwater Drive Des Plaines, IL

P: 847/803-5000 F: 847/803-5454

Technical: 800/TEC-TRUE www.chicagofaucets.com

900 Series Lab Fittings

909-AGVCP

Product Type

Single ball valve for wall or turret mount

Features & Specifications

Laboratory nozzle with 10 serrations for laboratory hose CFNow! Item Ships in 3 Days

Performance Specification

Rated Operating Pressure: by service (maximum): Acetylene (7.25 PSI); Ammonia (7.25 PSI); Argon (7.25 PSI); Butane (7.25 PSI); Carbon Dioxide (7.25 PSI); Carbon Monoxide (7.25 PSI);

Helium (7.25 PSI); Hydrogen (7.25 PSI); Natural Gas (7.25 PSI);

Methane (7.25 PSI); Nitrogen (7.25 PSI); Propane (7.25 PSI); Air (125 PSI); Compressed Air (125 PSI); Cold Water (125 PSI)

Warranty

5-Year Limited Faucet Warranty Lifetime Limited Faucet Warranty 1-Year Limited Finish Warranty 5-Year Limited Mechanical Warranty

Codes & Standards

ADA ANSI/ICC A117.1

Last Revision: 11/24/2025 • Product specifications subject to change without notice

2100 South Clearwater Drive Des Plaines, IL

P: 847/803-5000 F: 847/803-5454

Technical: 800/TEC-TRUE www.chicagofaucets.com

909-AGVCP

Architect/Engineer Specification Chicago Faucets No. 909-AGVCP, Single Ball Valve, panel-mounted, chrome plated. Serrated, full-flow laboratory nozzle. 3/8" NPT male thread inlet. May be used with most laboratory gases. 909 Valve is Certified for Gas Service per ANSI Z21.15/CSA 9.1 by the Canadian Standards Association.

Operation and Maintenance Installation should be in accordance with local plumbing codes. Flush all pipes thoroughly before installation. After installation, remove spout outlet or flow control and flush faucet thoroughly to clear any debris. Care should be taken when cleaning the product. Do not use abrasive cleaners, chemicals or solvents as they can result in surface damage. Use mild soap and warm water for cleaning and protecting the life of Chicago Faucet products. For specific operation and maintenance refer to the installation instructions and repair parts documents that are located at www.chicagofaucets.com.

Chicago Faucets, member of the Geberit Group, is the leading brand of commercial faucets and fittings in the United States, offering a complete range of products for schools, laboratories, hospitals, office buildings, food service, airports and sport facilities. Call 1.800.TECTRUE or 1.847.803.5000 Option 1 for installation or other technical assistance.

Last Revision: 11/24/2025 • Product specifications subject to change without notice Powered by TCPDF (www.tcpdf.org) www.chicagofaucets.com http://www.tcpdf.org

File details come from the government source that posted it. Updated .