9-A-201-A4.pdf

PDF 418 KB Posted

Attached to
Library Renovation To The Blue Bell Branch Library
Solicitation number
Not on record
Issued by
Montgomery County, Pennsylvania

About this file

This is an architectural elevation drawing set for the Library Renovation to the Blue Bell Branch Library project administered by the Wissahickon Valley Public Library in Blue Bell, Pennsylvania. The document provides detailed demolition and new work elevations for the exterior of the library building located at 650 Skippack Pike. The project scope includes removal of existing signage, metal cladding, gutters, and downspouts; creation of new openings in CMU walls for windows, doors, and a book drop; installation of new fiber cement siding (Hardie Board plank), metal panel siding (AlucoBoard Plus), smooth cobblestone accents, and a TPO roofing system on the canopy; installation of 12-inch high aluminum letters for signage; and repointing of existing masonry. The drawing set shows north and east elevations in both demolition and new work phases, with detailed specifications for materials including powder-coated aluminum components, new concrete paving, and a new steel tube column. The sealed proposal deadline is 10:00 a.m. on Thursday, September 15, 2026, with written questions due by end of business Friday, September 11, 2026. Electronic copies of drawings and specifications became available beginning Tuesday, August 25, 2026 through PennBid.

The complete project involves general construction as a single prime contract and encompasses demolition and reconstruction of interior partitions and finishes, construction of a new entrance feature, and selected addition of exterior doors and windows. A Performance Bond and Labor and Materials Bond in the amount of 100 percent of the contract value are required, along with a Maintenance Bond in the amount of 25 percent. All proposals must be submitted through PennBid in the prescribed form and accompanied by a bid guaranty as specified in the Instruction to Bidders. Questions regarding project scope should be directed to PennBid rather than the library or architect, as PennBid will forward technical inquiries to the architect as needed. The work is defined by the complete contract documents, which include structural drawings for lintel information and column specifications.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LIBRARY

REMOVE EXISTING

SIGNAGE AND ALL

ASSOCIATED

COMPONENTS.

REMOVE EXISTING

METAL CLADDING AND

GUTTER DOWN TO

EXISING FRAMING.

CREATE NEW OPENING

IN CMU WALL FOR NEW

WINDOW OPENING.

CREATE NEW OPENING

IN CMU WALL FOR NEW

DOOR OPENING.

REMOVE EXISTING

DOORS. FRAME TO

REMAIN.

REMOVE ALL

DOWNSPOUTS FOR

INSTALLATION OF NEW.

CREATE NEW OPENING

IN CMU WALL FOR NEW

BOOK DROP OPENING.

WISSAHICKON PUBLIC LIBRARY

A404

SIM.

A404

A404

A404

A404

SIM.

A502

9' -6

FI

BE

R C

EM

EN

T

SI

D

IN

G

BO

D

H

AR

D

IE

B O

AR

D

P

LA

N K

6" E

XP

O

SU

R

E

SM

O O

TH

C

O

BB

LE

S

TO

N

E

5' -0

/- M

ET

AL

P

AN

EL

S

ID

IN

G

BO

D

AL

U

C O

BO

N

D P

LU

S

PA

N

EL

S

O N

E

AS

YF

IX

S

TR

U C

TU

R

E 8"

P

AN

EL

S

IN

ST

AL

LE

D A

T ~2

1° N

EW

A

G E

BR

O

N

ZE

'-6

/- M

ET

AL

P

AN

EL

S

ID

IN

G

BO

D

AL

U C

O

BO

N D

P

LU

S

PA

N

EL

S O

N E

AS

YF

IX

S

TR

U

C

TU

R E

8" P

AN

EL

S

IN

ST

AL

LE

D

A T

~2 1°

N

EW

A G

E

BR

O N

ZE

W106 W107 W108 W109 D100A D123A

ENTIRE LENGTH

12" HIGH ALUMINUM PIN

LETTERS MOUNTED TO

CANOPY ROOF.

A502

PATCH WALL AT BOOK

DROP OPENING AS

REUQIRED FOR NEW

DOOR OPENING.

BOOK DROP OPENING.

D135C D100A W101 W102 W103 W104 W105

9' -6

CREATE NEW OPENING

IN CMU WALL FOR NEW

WINDOW OPENING.

CREATE NEW OPENING

IN CMU WALL FOR NEW

DOOR OPENING.

CREATE NEW OPENING

IN CMU WALL FOR NEW

WINDOW OPENING.

REMOVE EXISTING

DOOR. FRAME TO

REMAIN.

WISSAHICKON PUBLIC LIBRARY

POWDER COATED ALUMINUM SCUPPER AND DOWNSPOUT.

PROVIDE 24x36 CONCRETE SPLASHBLOCK. TYPICAL BOTH SIDES.

EXISTING WINDOWS TO REMAIN.

EXISTING STOREFRONT TO

REMAIN.

BOOK DROP. FRAME AROUND FOR

NEW SIDING.

D123A

APPROVED

R E V I S I O N S

D R A W I N G #

D R A W I N G T I T L E

S C A L E

D A T E

C H E C K E D

D R A W N

P R O J E C T T I T L E

S E A L

C O N S U L T A N T S

SYMBOL DATE DESCRIPTION

D O N O T S C A L E D R A W I N G S

AS NOTED

AUGUST 21, 2026

W

IS

SA

HI

CK

ON

L

IB

RA

RY

IN

TE

RI

OR

IM

PR

OV

EM

EN

TS

SK

IP

PA

CK

P

IK

E

BL

UE

B

EL

L, P

EN

NS

YL

VA

NI

A

ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTOR

AND THE ARCHITECT NOTIFIED OF ANY

DISCREPANCIES BEFORE PROCEEDING WITH THE

CONSTRUCTION

AMCJr.

ALBERT M. COMLY JR.

ARCHITECT

BID DOCUMENTS

ELEVATIONS

A-201

SCALE= 3/32" = 1'-0"

NORTH ELEVATION - DEMOLITION

GENERAL NOTES:

CONSTRUCTION NOTES:

LEGEND:

SCALE= 3/32" = 1'-0"

NORTH ELEVATION - NEW WORK

SCALE= 3/32" = 1'-0"

EAST ELEVATION - DEMOLITION

3 SCALE= 3/32" = 1'-0"

EAST ELEVATION - NEW WORK

SCALE= 1/4" = 1'-0"

NORTH ELEVATION - ENTRY

1 9/8/2026 ADDENDUM #1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text SPOT REPOINT AS REQUIRED. JOINT PROFILE TO MATCH EXISTING. ASSUME 25% OF AREA TO BE REPOINTED. EXISTING WINDOW TO REMAIN. INSTALL BACKER ROD AND SEALANT AT ENTIRE PERIMETER. REMOVE AND INSTALL NEW GLAZING COMPOUND. NEW BASE UNIT CABINETS/ COUNTERTOP. PATCH ALL FINISHES WHERE ELEMENTS HAVE BEEN REMOVED THROUGHOUT EXISTING BUILDING. PAINT TO MATCH ADJACENT SURFACES. EXISTING ROOFING TO REMAIN. REMOVE ALL EXISTING DEBRIS. TPO ROOFING SYSTEM ON CANOPY CONSTRUCTION. EXISTING DOWNSPOUT AND CONDUCTOR HEAD TO REMAIN. POWDER COATED GUTTER AND 3x4 RECTANGULAR ALUMINUM DOWNSPOUT WITH PAINTED CAST IRON BOOT. NEW WINDOW OPENING IN EXISTING MASONRY WALL. SEE STRUCTURAL DRAWINGS FOR LINTEL INFORMATION. EXISTING FLAG POLE TO REMAIN. NEW CONCRETE PAVING. 12" HIGH ALUMINUM LETTERS - SATIN ANODIZED FINISH - FLAT FACE. LETTERS SHALL SET ON PINS ON CANOPY ROOF. NEW EXTERIOR CLADDING SYSTEM. PATCH DAMAGED GWB - 2SF. NEW STEEL TUBE COLUMN, SEE STRUCTURAL DRAWINGS. INSTALL 6" ROUND POWDER COATED COLUMN COLOR. NEW FOLDING WALL PARTITION. BOD - MODERNFOLD PAIRED PANEL ACOUSTI-SEAL LEGACY - STC 50. LAMINATE GWB OVER EXISTING FABRIC WALL FINISH. INSTALL CHAIR RAIL ALONG ENTIRE WALL @ 3'-0" AFF. PROFILE = TR-1. NEW DRINKING FOUNTAIN/ BOTTLE FILLER. PROVIDE BLOCKING IN WALLS FOR WALL MOUNTED TV. REPAINT CMU WALLS. C-10. INFILL EXISTING OPENING WITH CMU TO MATCH EXISTING. INSTALL BOOK DROP OPENING THROUGH EXISTING CMU WALL. THROUGH WALL BOOK DROP CHUTE, CABINET, AND CART. BOD = AMERICAN SECURITY CABINETS EXTRA LARGE THROUGH WALL DOUBLE BOOK AND MEDIA LIBRARY RETURN 910 WITH POWDER COATED BOOK TRUCK. STEEL TUBE COLUMN, SEE STRUCTURAL DRAWINGS. OPEN, REFRAME, AND PATCH WALL AS REQUIRED FOR INSTALLATION.

AutoCAD SHX Text

AutoCAD SHX Text DO NOT SCALE THE DRAWINGS. THE DRAWINGS REPRESENT THE GENERAL EXISTING CONDITION AND LAYOUT. THEY DO NOT NECESSARILY REPRESENT A COMPLETE FIELD VERIFIED LAYOUT. THE CONTRACTOR SHALL VERIFY THE LAYOUT AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING. ALL DIMENSIONS ARE TO OUTSIDE FACE OF FINISH MATERIALS. ALL DIMENSIONS SHALL BE CONFIRMED IN THE FIELD PRIOR TO WORK BEING COMPLETED. THE WORK CONSISTS OF RENOVATION OF AN EXISTING STRUCTURE. EXERCISE EXTREME CARE IN ALL ASPECTS OF THE WORK. DO NOT USE METHODS WHICH WILL RESULT IN UNNECESSARY DAMAGE. ALL EXISTING ROOMS SHALL RECEIVE NEW FINISHES (PAINT, CEILINGS, CARPET) UNLESS NOTED OTHERWISE. SEE FINISH SCHEDULE ON SHEET A-602 FOR ADDITIONAL INFORMATION. ALL FURNITURE IS NOT IN CONTRACT UNLESS NOTED OTHERWISE. FURNITURE IS SHOWN FOR INFORMATION PURPOSES ONLY. REMOVE ALL EXISTING BIRD AND INSECT NESTS FROM BUILDING. REMOVE ALL DEBRIS FROM EXISTING GUTTERS AND DOWNSPOUTS. REINSTALL SIGNAGE. COORDINATE LOCATIONS WITH LIBRARIAN.

AutoCAD SHX Text 1.

AutoCAD SHX Text 2.

AutoCAD SHX Text 3.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING WALL.

AutoCAD SHX Text

AutoCAD SHX Text D###

AutoCAD SHX Text

AutoCAD SHX Text 4.

AutoCAD SHX Text 5.

AutoCAD SHX Text 6.

AutoCAD SHX Text 7.

AutoCAD SHX Text 8.

AutoCAD SHX Text 9.

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING DOOR.

AutoCAD SHX Text

NEW WALL.

AutoCAD SHX Text

NEW DOOR.

AutoCAD SHX Text

KEY NOTE.

AutoCAD SHX Text

WINDOW NUMBER. SEE SHEET A-601 FOR INFORMATION

AutoCAD SHX Text

DOOR NUMBER. SEE SHEET A-601 FOR INFORMATION.

AutoCAD SHX Text

WALL TYPE. SEE SHEET A-501 FOR INFORMATION.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 10.

AutoCAD SHX Text