8-A-502-A4.pdf

PDF 270 KB Posted

Attached to
Library Renovation To The Blue Bell Branch Library
Solicitation number
Not on record
Issued by
Montgomery County, Pennsylvania

About this file

This is an architectural detail drawing for the Wissahickon Valley Public Library's Blue Bell Branch Library renovation project located at 650 Skippack Pike, Blue Bell, Pennsylvania 19442. The drawing, prepared by Albert M. Comly Jr. Architect and dated August 21, 2026 (revised September 6, 2026), provides construction details for the building exterior work. The drawing includes eleven detailed sections at various scales addressing critical building envelope components: gutter, siding transition, window head, window sill, soffit, door head, canopy fascia, canopy column, canopy joint to existing building, building corner, and exterior pier. The renovation scope involves removal of existing metal cladding, installation of fiber cement lap siding with 6-inch exposure, new aluminum storefront windows, metal panel siding (Alucobond Plus panels on Easyfix structure), TPO roofing membrane with flashing, waterproofing membranes (Henry Blueskin SA), galvanized steel furring strips, and powder-coated aluminum components throughout. The drawings are scaled at 3/8 inch equals 1 foot-0 inches for most details and 1-1/2 inches equals 1 foot-0 inches for the exterior pier section. Sealed proposals for the general construction work are due by 10:00 A.M. on Thursday, September 15, 2026, with the last day for submitting written technical questions being Friday, September 11, 2026.

The drawing specifications require shop drawings and mock-ups for review of both fiber cement and metal siding installation prior to full installation. Performance and Labor and Materials Bonds in the amount of 100 percent are required, along with a Maintenance Bond of 25 percent. All dimensions must be verified by the contractor and any discrepancies reported to the architect before construction begins. Electronic copies of the complete drawings and specifications are available through PennBid beginning August 25, 2026, with all questions directed to PennBid rather than directly to the architect or library. The project represents a comprehensive interior and exterior renovation including demolition, reconstruction of interior partitions and finishes, construction of a new entrance feature, and selected addition of doors and windows.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE= 3 = 1'-0"

NORTH GUTTER

SCALE= 3 = 1'-0"

SIDING TRANSITION

SCALE= 3 = 1'-0"

WINDOW HEAD

SCALE= 3 = 1'-0"

WINDOW SILL

SCALE= 3 = 1'-0"

SOFFIT

SCALE= 3 = 1'-0"

DOOR HEAD

SCALE= 3 = 1'-0"

CANOPY FASCIA

SCALE= 3 = 1'-0"

CANOPY COLUMN

6 SCALE= 3 = 1'-0"

CANOPY JOINT TO EXTG BUILDING

SCALE= 3" = 1'-0"

BUILDING CORNER

EXISTING ROOFING TO REMAIN.

61 4"

7"

FLASHING TO EXTEND INTO NEW

GUTTER. SEAL AGAINST EXISTING

ROOFING PER MANUFACTURER'S

RECOMMENDATIONS.

7" POWDER COATED ALUMINUM BOX

GUTTER.

1"

REMOVE EXISTING METAL CLADDING

DOWN TO FRAMING.

EXISTING FRAMING TO REMAIN.

4" MARINE GRADE PLYWOOD

SHEATHING.

METAL SIDING. BOD = ALUCOBOND

PLUS PANELS ON EASYFIX STRUCTURE.

3 8"

WATERPROOFING MEMBRANE. BOD = HENRY BLUESKIN SA.

4" THICK PAINTED OAK SILL.

ALUMINUM STOREFRONT WINDOW

SYSTEM.

MODIFY EXISTING FRAMING FOR NEW

OPENING.

EXISTING CMU WALL. SAWCUT FOR

NEW OPENING. PATCH AND PARGE AS

REQUIRED TO PREP SURFACE FOR NEW

CLADDING.

8" GALVANIZED METAL FURRING @ 24"

O.C.

WATERPROOFING MEMBRANE.

POWDERCOATED ALUMINUM PAN

FLASHING.

SEALANT AND BACKER ROD.

2" TRIM BOARD.

SEALANT AND BACKER ROD.

FIBER CEMENT LAP SIDING. 1"

LETTERS ON PINS.

TPO ROOFING MEMBRANE. TURN

DOWN BLOCKING.

MARINE GRADE PLYWOOD SHEATHING.

TPO FLASHING OVER FLASHING.

P.T. BLOCKING.

TAPERED XPS INSULATION TO CREATE

SLOPE TO DRAINS.

POWDER COATED METAL FLASHING.

P.T. BLOCKING.

6" CFMF. SEE STRUCTURAL DRAWINGS.

1'- 8"

POWDER COATED METAL FLASHING.

POWDER COATED METAL FASCIA WITH

DRIP EDGE.

INSECT SCREENING.

8" GALVANIZED STEEL FURRING STRIPS.

JOINT CLIP.

4MM ALUMINUM PANELS WITH 38" GAP

BETWEEN PANELS.

METAL PANEL SIDING

BOD - ALUCOBOND PLUS PANELS

ON EASYFIX STRUCTURE

8" PANELS INSTALLED AT ~21°

NEW AGE BRONZE

WATERPROOFING MEMBRANE.

EXISTING FRAMING TO REMAIN.

MARINE GRADE PLYWOOD SHEATHING.

POWDER COATED METAL FLASHING.

INSECT SCREENING.

FIBER CEMENT TRIM BOARD.

6" EXPOSURE FIBER CEMENT LAP

SIDING.

SEE DETAIL 4/A502 FOR ADDITIONAL

INFORMATION.

EXISTING FRAMING TO REMAIN.

POWDER COATED METAL FLASHING.

INSECT SCREENING.

METAL SIDING (SAME COLOR AS

DIAGONAL BOARDS) SET PARALLEL TO

WALL.

3 8"

INSECT SCREENING.

8" GALVANIZED STEEL FURRING STRIPS.

JOINT CLIP.

4MM ALUMINUM PANELS WITH 38" GAP

BETWEEN PANELS. BOD = ALUCABOND

EASY FIX.

FASCIA BEYOND.

TAPERED XPS INSULATION TO CREATE

SLOPE TO DRAINS.

MARINE GRADE PLYWOOD SHEATHING.

SEE STRUCTURAL DRAWINGS FOR

FRAMING INFORMATION.

ALUMINUM SOFFIT.

JOINT CLIP.

8" GALVANIZED FURRING STRIPS @ 4"

O.C.

INSECT NETTING. TURN DOWN AND

FASTEN TO COLUMN.

SEE DETAIL 4/A502 FOR ADDITIONAL

INFORMATION.

POWDER COATED ALUMINUM FLASHING

TURN UP BEHIND SIDING.

LOOSE LOCK SEAM TO ALLOW FOR 1"

EXPANSION.

TPO FLASHING.

POWDER COATED ALUMINUM

FLASHING.

1" 1"

4"

6" 6"

M

IN

P.T. BLOCKING.

TPO ROOFING.

1"

ALUMINUM SOFFIT. ALUMINUM SOFFIT.

6" EXPOSURE FIBER CEMENT LAP

SIDING.

POWDER COATED ALUMINUM

FLASHING.

STEEL LINTELS. SEE STRUCTURAL

DRAWINGS.

STARTER STRIP.

GWB RETURN.

SEALANT AND BACKER ROD.

INSECT NETTING.

FIBER CEMENT TRIM BOARD.

SEALANT AND BACKER ROD.

ALUMINUM STOREFRONT WINDOW.

FURRING STRIP.

BACKER ROD AND SEALANT.

ALUMINUM SOFFIT.

EXISTING STOREFRONT TO REMAIN.

PREPARE, PRIME AND PAINT.

EXISTING PAINTED CMU WALL.

FIBER CEMENT TRIM BOARDS.

8" GALVANIZED FURRING STRIPS @ 4"

O.C.

WATERPROOFING MEMBRANE.

2"

31 2"

8"FIBER CEMENT SIDING.

*PROVIDE SHOP DRAWAINGS

AND MOCK UP FOR REVIEW OF

BOTH FIBER CEMENT AND METAL

SIDING INSTALLATION PRIOR TO

FULL INSTALLATION.

1 1

INSECT SCREENING.

SCALE= 1-1/2" = 1'-0"

EXTERIOR PIER

EXISTING WINDOW TO REMAIN.

FIBER CEMENT TRIM BOARDS.

FIBER CEMENT LAP SIDING.

3 8"

GALV. FURRING STRIPS.

WATERPROOFING MEMBRANE.

EXISTING CMU WALL.

APPROVED

R E V I S I O N S

D R A W I N G #

D R A W I N G T I T L E

S C A L E

D A T E

C H E C K E D

D R A W N

P R O J E C T T I T L E

S E A L

C O N S U L T A N T S

SYMBOL DATE DESCRIPTION

D O N O T S C A L E D R A W I N G S

AS NOTED

AUGUST 21, 2026

W

IS

SA

HI

CK

ON

L

IB

RA

RY

IN

TE

RI

OR

IM

PR

OV

EM

EN

TS

SK

IP

PA

CK

P

IK

E

BL

UE

B

EL

L, P

EN

NS

YL

VA

NI

A

ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTOR

AND THE ARCHITECT NOTIFIED OF ANY

DISCREPANCIES BEFORE PROCEEDING WITH THE

CONSTRUCTION

AMCJr.

ALBERT M. COMLY JR.

ARCHITECT

BID DOCUMENTS

DETAILS

A-502

1 9/6/2026 ADDENDUM #1

Sheets and Views
A4