03 D-04 Emer Mask requirements.pdf

PDF 22 KB Posted

Attached to
Specialized, Engineering, Aeronautics, and Manufacturing (SEAM) II Solicitation
Solicitation number
80JSC020R0045
Issued by

View the file

Other files

File Type Posted
SEAM II SF-30 Amendment 4.pdf PDF
LFT_User_Guide.pdf PDF
SEAM II SF-30 Amendment 3.pdf PDF
LFT_Quick_Start_Guide.pdf PDF
80JSC020R0045 SEAM II SF-33.pdf PDF
SF-30 SEAM II Amendment 2.pdf PDF
Attachment IV L.32.6 Price Templates.xlsx XLSX spreadsheet
SF-30 SEAM II.pdf PDF
Attachment 2 SEAM II RFP 80JSC020R0045.pdf PDF
Amendment 1 SEAM II Final RFP Questions and Responses.pdf PDF
Attachment III L.32.2 Past Performance Reference Table.xlsx XLSX spreadsheet
Attachment 1 Signed SEAM II Cover Letter.pdf PDF
Attachment V 80JSC020R0045 Track Changes.docx DOCX document
Modification 3 SEAM II Final RFP Questions and Responses.pdf PDF
Modification 2 Final RFP Questions and Responses.pdf PDF
07 Price Breakout SEAM E-15.xlsx XLSX spreadsheet
02 SEAM D04 Emergency Mask Trainers.pdf PDF
06 SEAM E-15 SOW DETAIL ISS Power Supply.pdf PDF
04 Mask Measurements.pdf PDF
SEAM II Pre-proposal Conference Charts.pdf PDF
05 SEAM RFP Coversheet E-15.pdf PDF
01 Fidelity Classification Matrix.pdf PDF
SEAM Sec L - L_32_1 Relevant Past Performance Matrix.xlsx XLSX spreadsheet
80JSC020R0045 SEAM II Final RFP.pdf PDF
SEAM Sec L - L_32_2 Past Performance Reference Table.xlsx XLSX spreadsheet
SEAM Sec L - L_32_6 Price Templates.xlsx XLSX spreadsheet
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

[Facility]-SEAM-FRM-001 Page of 4 1

Task NO.: SEAM Proposal Request

TASK TITLE: Emergency Mask Trainers

REQUIREMENTS/REFERENCES:

1. Reverse engineer and build 10 ea. Emergency Mask trainers from provided documentation and photos.

1.1 Hardware Overview

The Emergency Mask is a secondary response emergency Personal Protection Equipment (PPE) designed to provide respiratory protection to the ISS crew in response to a post-fire event or ammonia leak. One size fits all, the fit ranges from the 5th percentile Japanese female to the 95th percentile American male. The Emergency Mask is designed to use two Fire Cartridges (FCs), or two Ammonia Cartridges (ACs. The Emergency Mask will seal around the neck to prevent a crewmember from inhaling contaminants

2.0 Hood Design:

2.1 Hood shall be dark Navy Blue gore fabric with a white Gore lining.

2.1.1 Yoke assembly for the hood adjustment straps

2.2 Hood adjustment strap shall be black 1 inch strapping, nomex or similar material

2.2.1 Attaches to the Yoke assembly

2.2.2 Uses 2 ea “d” rings for adjustment on each side of the yoke, II B fidelity

2.2.3 2 ea retaining loops integrated onto the hood

2.3 Visor is 0.010” thick clear PET polyester film or equivalent

2.3.1 Visor should be resistant to deformation that would prevent the user from reading a checklist/procedure, i.e.

crinkling

2.3.2 Visor material shall be pliable.

2.3.3 Visor shall be treated for Anti-Fog. Material treatment or wipe on application

2.3.4 The visor shall be replaceable

2.3.5 2 ea spare visors shall be provided for each mask

2.4 Nose cup: integrated with respiratory interfaces

2.4.1 Exhalation port 1 ea

2.4.2 inhalation ports with bayonet fittings to support the 3M cartridges 2 ea

2.4.3 Dual bayonet connectors accommodate either:

2.4.3.1 Fire Cartridges 2 ea

2.4.3.2 3M Ammonia Cartridges 2 ea Note: Training cartridges will be provided for testing/fit check and alignment DOT placement

2.5 Neck Seal Design

2.5.1 Neck dam is JSAM neck dam

2.5.2 Material is molded bromo-butyl rubber or similar material

2.5.3 Neck Dam shall be replaceable

2.5.3.1 2 ea spare neck dams shall be provided for each mask.

2.6 Fabricate and install mask labels. See provided photos. Serial numbers will start with SVMF0001

2.7 Option to procure an additional 6 ea Emergency Mask Trainers with spares

3.0 Operational requirement: Hood should inflate when the user “clears” the mask by covering the exhalation port.

Seals at the neck, seal does not need to be maintained after demonstrating the “clearing process”.

Attachment:

Emergency Mask overview and photos.

[Facility]-SEAM-FRM-001 Page of 4 2

ACCEPTANCE CRITERIA/DELIVERABLES DEFINITION:

1. Deliver to:

NASA Johnson Space Center 2101 NASA Parkway Houston, Texas 77058 Deliver to: B9NW/SVMF Attn: John Foss

SCHEDULE MILESTONES: (complete or reference separate project plan)

[Facility]-SEAM-FRM-001 Page of 4 3

BASIS OF ESTIMATE

Include and identify significant assumptions: (complete or reference separate project plan)

RISK ASSESSMENT

Include risk associated with facility cost for maintenance in out years: (complete or reference separate project plan)

MAJOR COST AND SCHEDULE DRIVERS: (complete or reference separate project plan)

[Facility]-SEAM-FRM-001 Page of 4 4

DELIVERABLES:

Materials List Proof Loading Drawing Package (Paper and Electronic) Lift Plan Stress Analysis/Stress Models Mass Properties Welding Report Tip Over Analysis Project Design Review. PDR CDR General Design Review Hazard Analysis Operation/maintenance instructions Assembly/Installation instructions Status Reports (DRD XXX) Weekly Bi-weekly Monthly None Test Readiness Review Package Flight Readiness Review Package