8 of 8 - 589A7-21-702 Tech Dwgs.pdf

PDF 2 MB Posted

Attached to
Y1DA--589A7-21-702 EHRM Training and Admin Support Space (TASS) Construction - Wichita, KS
Solicitation number
36C77622B0033
Issued by

About this file

This solicitation seeks a general contractor to complete renovations for Project #589A7-21-702: EHRM Training and Admin Support Space (TASS) Construction at the Robert J. Dole VA Medical Center in Wichita, Kansas. The project involves renovations of approximately 12,000 square feet on the ground level of Building 61, including furnishing all labor, materials, equipment, and supervision to complete the specifications and drawings. The Department of Veterans Affairs Technology Acquisition Center Austin is the contracting agency.

View the file

Other files

File Type Posted
36C77622B0033 0006.pdf PDF
Tech Questions - Wichita TASS - 7-19-22.pdf PDF
Geotech Report - Wichita.pdf PDF
36C77622B0033 0005.pdf PDF
61_E-600_ADD1.pdf PDF
61_M-601-MECHANICAL SCHEDULES_ADD1.pdf PDF
DBA Wage Rates - Sedgwick County - 07-08-22.pdf PDF
Tech Questions - Wichita TASS - 7-14-22.pdf PDF
36C77622B0033 0004.pdf PDF
Spec Section 23 73 00_ADD1.pdf PDF
61_ES100_ADD1.pdf PDF
36C77622B0033 0003.pdf PDF
36C77622B0033 0002.pdf PDF
DBA Wage Rates - Sedgwick County - 06-17-22.pdf PDF
36C77622B0033 0001.pdf PDF
DBA Wage Rates - Sedgwick County - 06-03-22.pdf PDF
Pre-Bid Site Visit Sign-in Sheet - Wichita TASS.pdf PDF
V02 589A7-21-702 IFC Specifications.pdf PDF
1 of 8 - 589A7-21-702 General Dwgs.pdf PDF
V01 589A7-21-702 IFC Specifications.pdf PDF
Infection Control Risk Assessment.pdf PDF
589A7-21-702 Project Narratives.pdf PDF
5 of 8 - 589A7-21-702 Plumbing Dwgs.pdf PDF
3 of 8 - 589A7-21-702 Arch Dwgs.pdf PDF
2a of 8 - 589A7-21-702 Civil Dwgs.pdf PDF
2b of 8 - 589A7-21-702 Civil Dwgs.pdf PDF
6 of 8 - 589A7-21-702 Mech Dwgs.pdf PDF
Limitations on Subcontracting.docx DOCX document
Contractor Safety and Environmental Form.docx DOCX document
VHA Supp Contract Reqs COVID-19 - 12-14-21.pdf PDF
Wichita IFB 36C77622B0033 - 6-2-22.pdf PDF
DBA Wage Rates - Sedgwick County - 04-08-22.pdf PDF
4 of 8 - 589A7-21-702 Fire Dwgs.pdf PDF
7 of 8 - 589A7-21-702 Elec Dwgs.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABBREVIATIONS

STANDARD MOUNTING HEIGHTSANNOTATION

ELECTRICAL:

AUDIBLE APPLIANCES (CENTERLINE) 84"

ALARMS 48"

ANNUNCIATOR PANELS 48"

CLOCK OUTLETS (CENTERLINE) 84"

CONTROLS (TOP) 48"

EXIT SIGNS (WALL-MOUNTED, BOTTOM) 80"

FIRE ALARM ANNUNCIATOR PANEL (DISPLAY) 60"

FIRE ALARM BELL (EXTERIOR) 120"

FIRE ALARM CONTROL PANEL/UNIT (DISPLAY) 60"

INTERCOM (AFEA ONLY) 36"

INTERCOMS (TOP) 48"

PANELS & PANELBOARDS (TOP) 72"

PULL STATIONS (HANDLE) 48"

PHOTOCELLS 144"

RECEPTACLES (BOTTOM) 18"

RECEPTACLES (EXTERIOR) 24"

RECEPTACLES (GARAGES) 26"

RECEPTACLES IN EQUIPMENT ROOMS (TOP) 48"

REMOTE INDICATING LIGHT (EQUIPMENT ROOMS) 48"

REMOTE INDICATING LIGHT (FINISHED AREAS) CEILING

SAFETY SWITCHES & STARTERS 48"

SWITCHES (TOP) 48"

TELEPHONE/DATA/TV OUTLETS (BOTTOM) 18"

VISIBLE APPLIANCES (CENTERLINE) 84"

(AFF, AFG UNLESS NOTED OTHERWISE)

CU

MECHANICAL OR FIRE SPRINKLER PLAN NOTE CALL OUT

PLUMBING PLAN NOTE CALL OUT

ELECTRICAL, TECHNOLOGY OR FIRE ALARM PLAN NOTE

CALL OUT

PLUMBING EQUIPMENT DESIGNATION

EQUIPMENT DESIGNATION TAG

OWNER FURNISHED, CONTRACTOR INSTALLED

EQUIPMENT DESIGNATION

NEW WORK TO EXISTING WORK CONNECTION POINT

Z

BC

CB

B

DS

E

EP

LS

KS

NA

NM

SS

PS

PS

IC

CATV

FO

T

T/D

D

S

IC

UC

CCTV

S

WAP

#D/#TV

M

S

V

CR

DB

DB

DM

EL

EO

GB

KP

MD

PB

RE

EC

KT

GO

C

COMMUNICATIONS OUTLET, TYPE AS NOTED

COMMUNICATIONS OUTLET, FLOOR BOX, TYPE AS NOTED

WIRELESS ACCESS POINT, CEILING MOUNTED

COMMUNICATIONS OUTLET, CEILING MTD, TYPE AS NOTED

SPEAKER, WALL MOUNTED

SPEAKER, CEILING MOUNTED

SERVER RACK, TWO-POST, FLOOR MOUNTED

3/4"x4'x8', FIRE-RATED PLYWOOD BACKBOARD

GROUND BAR, TYPE AS NOTED

SERVER RACK, WALL MOUNTED

CABLE TRAY, TYPE AS NOTED

CABLE TELEVISION LINE

FIBEROPTIC LINE

TELEPHONE LINE

TELEPHONE/DATA LINE

DATA LINE

SPEAKER LINE

INTERCOM LINE

INTERCOM, "M" DENOTES MASTER STATION

VOLUME CONTROL, WALL MOUNTED

CODE BLUE PUSHBUTTON STATION

DUTY STATION

STAFF EMERGENCY ASSIST STATION

PATIENT EMERGENCY PULL CORD STATION

STAFF LOCATOR SENSOR

NURSE CALL KEY SWITCH

NURSE CALL VISUAL ANNUNCIATOR PANEL

NURSE CALL MASTER STATION

STAFF STATION (NORMAL, EMERGENCY & CODE BLUE)

DOME LIGHT, WALL MOUNTED

DOME LIGHT, CEILING MOUNTED

ZONE DOME LIGHT

MULTI-SERVICE POWER POLE WITH POWER/DATA,

TYPE AS NOTED AND/OR SCHEDULED

UNDERGROUND COMMUNICATIONS LINE,

CABLING TYPE AS NOTED

MULTI-SERVICE FLOOR BOX/POKE-THRU WITH POWER/DATA,

TYPE AS NOTED AND/OR SCHEDULED

SERVER RACK, FOUR-POST, FLOOR MOUNTED

SERVER CABINET, FLOOR MOUNTED

CLOSED CIRCUIT TELEVISION LINE, MIN. 1" RACEWAY

CARD READER, PROXIMITY TYPE

DOOR BELL PUSHBUTTON

DOOR BELL CHIME

DOOR POSITION MONITOR

ELECTRIFIED LOCKING DEVICE, REQUEST TO EXIT SENSOR,

LATCH BOLT MONITOR, AND DOOR POSITION SWITCH

ELECTRIFIED LOCKING DEVICE

GLASS BREAK DETECTOR

INTRUSION DETECTION KEYPAD

INTRUSION DETECTION MOTION DETECTOR

DURESS PUSHBUTTON

REQUEST TO EXIT BUTTON

SINGLE VIEW SECURITY CAMERA

EMERGENCY CALL STATION

RFID KEY TAG READER

GATE OPENER

DUAL VIEW SECURITY CAMERA

180-DEGREE PANORAMIC VIEW SECURITY CAMERA

270-DEGREE PANORAMIC/MULTI-IMAGE VIEW

360-DEGREE PANORAMIC/MULTI-IMAGE VIEW

SECURITY CAMERA

SECURITY CAMERA

PATIENT STATION WITH BED CONNECTOR

PATIENT STATION WITH CODE BLUE

SECURITY SYMBOLS

#D = DATA, # = QUANTITY OF CABLES

#TV = CABLE TELEVISION, # = QUANTITY OF CABLES

#D = DATA, # = QUANTITY OF CABLES

#TV = CABLE TELEVISION, # = QUANTITY OF CABLES

#V = VOICE, # = QUANTITY OF CABLES

#D = DATA, # = QUANTITY OF CABLES

#E = ELEVATOR, # = QUANTITY OF CABLES

#FMS = FACILITY MONITORING SYSTEM,

# = QUANTITY OF CABLES

NURSE CALL SYMBOLS

COMMUNICATION SYMBOLS

#TV = CABLE TELEVISION, # = QUANTITY OF CABLES

#V = VOICE, # = QUANTITY OF CABLES

M (CONT'D)

MV MEDIUM VOLTAGE

MVA MEGAVOLT-AMPERE

MW MEGAWATT

X

W

V

U

T

S

R

P

O

N

M

L

K

J

I

H

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FABL FIRE ALARM BELL

FABX FIRE ALARM BOX

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FI FILM ILLUMINATOR

FIXT FIXTURE

FLA FULL LOAD AMPS

FLEX FLEXIBLE METALLIC CONDUIT

FLUOR FLUORESCENT

FO FIBER-OPTIC

FP FIRE PROTECTION

FT FEET OR FOOT

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

G

F

E

D

EC EMPTY CONDUIT

EG EQUIPMENT GROUND

EL ELEVATION

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMCP EMER. MONITORING CONTROL PANEL

EMER EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

ESMT EASEMENT

ETD EXISTING TO BE DEMOLISHED

ETR EXISTING TO REMAIN

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EXIST EXISTING

DB DECIBEL OR DIRECT BURIAL

DC DIRECT CURRENT

DCP DIMMER CONTROL PANEL

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLITION

DIAG DIAGRAM

DISC DISCONNECT

DISTR DISTRIBUTION

DISTR PNL DISTRIBUTION PANEL

DN DOWN

DPDT DOUBLE POLE, DOUBLE THROW

DPST DOUBLE POLE, SINGLE THROW

DRSW DOOR SWITCH

DS DISCONNECT SWITCH

DWG DRAWING

C CONDUIT

CAP CAPACITY

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/

CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER

INSTALLED

CFE CONTRACTOR FURNISHED

EQUIPMENT

CHW CHILLED WATER

CHWP CHILLED WATER PUMP

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CLF CURRENT LIMITING FUSE

CLG CEILING

CMU CONCRETE MASONRY UNIT

COAX COAX CABLE

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CU COPPER

CU FT CUBIC FEET

C

B

A

UFD UNDERFLOOR DUCT

UGND UNDERGROUND

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

VA VOLT AMPERE

VAR VOLT AMPERE REACTIVE

VCM VERTICAL CABLE MANAGER

VFD VARIABLE FREQUENCY DRIVE

VOLT VOLTAGE

TC TIME CLOCK

TEL TELEPHONE

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TYP TYPICAL

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

REC RECESSED

REQD REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

RU RACK UNIT

N NEUTRAL

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NS NO SCALE

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OL OVERLOAD

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MC METAL-CLAD

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MG MOTOR GENERATOR

MH MANHOLE

MIN MINIMUM

MOCP MAXIMUM OVERCURRENT PROTECTION

MLO MAIN LUGS ONLY

MT MOUNT

MTD MOUNTED

MTG MOUNTING

KV KILOVOLT

KVA KILOVOLT AMPERE

KVAH KILOVOLT AMPERE PER HOUR

KVAR KILOVOLT AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

KWHM KILOWATT HOUR METER

JB JUNCTION BOX

J-BOX JUNCTION BOX

XFER TRANSFER

XFMR TRANSFORMER

XP EXPLOSION PROOF

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LM LUMEN

LP LIGHT POLE

LPS LOW PRESSURE SODIUM

LRA LOCKED ROTOR AMPS

LTCP LOCAL TEMPERATURE CONTROL PANEL

LT LIGHT

LTG LIGHTING

LTG PNL LIGHTING PANEL

LTNG LIGHTNING

LV LOW VOLTAGE

W WATT

WH WATER HEATER

WP WEATHERPROOF

IESNA ILLUMINATION ENGINEERING SOCIETY

OF NORTH AMERICA

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

INCAND INCANDESCENT

IR INFRARED

IWH INSTANTANEOUS WATER HEATER

G OR GND GROUND OR GENERATOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GTB GROUND TERMINAL BOX

SCC SHORT CIRCUIT CAPACITY

SES SERVICE ENTRANCE SECTION

SD SMOKE DETECTOR

SF SQUARE FOOT (FEET)

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SPEC SPECIFICATION

SPST SINGLE POLE, SINGLE THROW

SURF SURFACE

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

P POLE

PA PUBLIC ADDRESS

PB PANELBOARD, PULL BOX, OR

PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT UNIT

PCB POLYCHLORINATED BIPHENYL

PEC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PNL PANEL

POD POWER OPERATED DAMPER

POE POWER OVER ETHERNET

PP PATCH PANEL

PT POTENTIAL TRANSFORMER

PTRV POWER TYPE ROOF VENTILATION

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

1P SINGLE POLE

1PH SINGLE-PHASE

3P THREE POLE

3PH THREE-PHASE

3W THREE WIRE

4W FOUR WIRE

A/C AIR CONDITIONING

A/E ARCHITECT/ENGINEER

AAP ALARM ANNUNCIATOR PANEL

AC ALTERNATING CURRENT OR ARMORED

ACC ACCESSIBLE

ADDL ADDITIONAL

ADJ ADJACENT, ADJOINING

ADO AUTOMATIC DOOR OPENER

AF AMPERE FRAME OR AMP FUSE

AFC ABOVE FINISHED COUNTER, AUTOMATIC

FREQUENCY CONTROL, OR

AVAILABLE FAULT CURRENT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AH AMPERE HOUR

AHJ AUTHORITY HAVING JURISDICTION

AIC AMPERE INTERRUPTING CAPACITY

ALT ALTERNATE

AMB OR A AMBIENT

AMP AMPERE

ARCH ARCHITECT

ASC AMPS SHORT CIRCUIT

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

HCM HORIZONTAL CABLE MANAGER

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HZ HERTZ

BAT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISH FLOOR

BIL BASIC INSULATION LEVEL

BLDG BUILDING

BLK BLOCK

BPIP BOILER PLANT

INSTRUMENTATION PANEL

BRKR BREAKER

BYP BY PASS

DETAIL REFERENCE

SECTION CUT DESIGNATION

EP-101

EP-101

WP - WEATHERPROOF

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

KS

KS

ARCH REG. NO.

ENGR REG. NO.

EXP. 12/31/2023

EXP. 12/31/2023

A-930, E-2586, CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

PLUMBING ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER

SPUR #: 1794.08

SPUR #: 1794.08

-J a n -2

:2

:4

TECHNOLOGY LEGEND, NOTES AND

ABBREVIATIONS

MIJ 81 88BEN

ISSUED FOR CONSTRUCTION

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

ADMINISTRATIVE SPACE

01/28/2022

589A7-21-702

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

T-000

No. REVISION DESCRIPTION DATE

01/28/2022

LO NG TERMADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICACUTE INPATIENTAM BULATO RY

LO NG TERM

ADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICM ENTAL HEALTHACUTE INPATIENTAM BULATO RYM ENTAL HEALTH

A

B C D E F G

OFFICE

005B

VETERANS BENEFIT SERVICE

STORAGE

004A

RESTROOM

RESTROOM

OFFICE

OFFICE

OFFICE

005A

TELECOM

006OFFICE

008D

KITCHENETTE

008E

REGIONAL OFFICE DIRECTOR

008A

DIRECTOR'S OFFICE

008G

OFFICE

005E

ELECTRICAL

STAIR

NORTH

ELEC

005D

COMMUNICATION

005C

10 10

TRAILER

LOT

B61

N

KEY PLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

KS

KS

ARCH REG. NO.

ENGR REG. NO.

EXP. 12/31/2023

EXP. 12/31/2023

A-930, E-2586, CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

PLUMBING ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER

SPUR #: 1794.08

SPUR #: 1794.08

-J a n -2

:2

:5

B61, GROUND LEVEL - TECHNOLOGY

DEMOLITION PLAN

MIJ 82 88BEN

ISSUED FOR CONSTRUCTION

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

ADMINISTRATIVE SPACE

01/28/2022

589A7-21-702

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

TD101

N

1/8" = 1'-0"

B61, GROUND LEVEL - TECHNOLOGY DEMOLITION PLAN1

ELECTRICAL KEYNOTES

7 NO TECHNOLOGY DEMOLITION IN THIS AREA.

8 ALL DATA DEVICES TO BE DEMOLISHED IN AREA OF WORK. REMOVE CONDUIT AND CABLES

BACK TO UPSTREAM DATA DISTRIBUTION.

10 DEMOLISH EXISTING PANEL. RELOCATE EXISTING SECURITY CIRCUITS TO NEW PANELBOARD.

PHASE DEMOLITION AND CONSTRUCTION SO THAT DISRUPTION TO SERVICE IS MINIMIZED.

AREA OF WORK

ADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICM ENTAL HEALTHACUTE INPATIENTAM BULATO RYM ENTAL HEALTH

C D E F G

INTERVIEW

103A

CHIEF

103B 103E 103F

RECEPTION / WAITING

INTERVIEW

103C

SECURITY FILES

103D

LOAN GUARANTEE DIVISION

ELECT CLOSET

PMS

110E

PERSONNEL

ASSISTANT CHIEF

110D

CHIEF

110C

PMS

110A

PMS

110B

110F 110G

TRAILER

LOT

B61

N

KEY PLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

KS

KS

ARCH REG. NO.

ENGR REG. NO.

EXP. 12/31/2023

EXP. 12/31/2023

A-930, E-2586, CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

PLUMBING ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER

SPUR #: 1794.08

SPUR #: 1794.08

-J a n -2

:2

:5

B61, FIRST LEVEL - TECHNOLOGY

DEMOLITION PLAN

MIJ 83 88BEN

ISSUED FOR CONSTRUCTION

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

ADMINISTRATIVE SPACE

01/28/2022

589A7-21-702

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

TD102

N

1/8" = 1'-0"

B61, FIRST LEVEL - TECHNOLOGY DEMOLITION PLAN1

AREA OF WORK

ELECTRICAL KEYNOTES

10 DEMOLISH EXISTING PANEL. RELOCATE EXISTING SECURITY CIRCUITS TO NEW PANELBOARD.

PHASE DEMOLITION AND CONSTRUCTION SO THAT DISRUPTION TO SERVICE IS MINIMIZED.

ADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICM ENTAL HEALTHACUTE INPATIENTAM BULATO RYM ENTAL HEALTH

A

B C D E F G

2D

1D/1TV

4D

2D

1D/1TV

1D/1TV

4D

4D 4D 4D 4D

4D

4D

1D/1TV

4D 4D 4D 4D

1D/1TV

2D 2D 2D 2D 2D 2D4D

1D/1TV

4D 4D 4D

1D/1TV

4D 4D 4D 4D

4D4D2D

2D 4D

6D 6D

CLASSROOM

002A

CLASSROOM

002B

OFFICE

001A

CORRIDOR

001-1

CLASSROOM

003A

CLASSROOM

003B

CLASSROOM

004A

CLASSROOM

004B

CLASSROOM

005A

CLASSROOM

005B

BREAK

006B

WAITING

006A

WAITING

001E

CORRIDOR

001-2

OFFICE

001D

OFFICE

TELECOM

008A

CORRIDOR

001-3

TOILET (W)

TOILET (M)

STOR.

001C

COFFEE

ELEC

001B

STAIR

NORTH

2D

2D

2D

2D

2D

2D

2D

AV

AV

+72"

+72"

+72"

+72"

+72"

+72"

+72"

4D

1D/1TV

+72"

AV

AV

AV

4D 4D 4D 4D

4D 4D 4D 4D

AV

AV

6D6D

+72"

2D

2D

2D

2D

4"D x 12"W

"D x

"W "D x

"W

4"D x 6"W

TRAILER

LOT

B61

N

KEY PLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

KS

KS

ARCH REG. NO.

ENGR REG. NO.

EXP. 12/31/2023

EXP. 12/31/2023

A-930, E-2586, CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

PLUMBING ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER

SPUR #: 1794.08

SPUR #: 1794.08

-J a n -2

:2

:5

B61, GROUND LEVEL - TECHNOLOGY PLAN

MIJ 84 88BEN

ISSUED FOR CONSTRUCTION

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

ADMINISTRATIVE SPACE

01/28/2022

589A7-21-702

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

TN101

N

1/8" = 1'-0"

B61, GROUND LEVEL - TECHNOLOGY PLAN1

AREA OF WORK

TECHNOLOGY KEYNOTES

17 PROVIDE 2" CONDUIT TO LOCATION OF TV.

ADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICM ENTAL HEALTHACUTE INPATIENTAM BULATO RYM ENTAL HEALTH

C D E F G

AV

6D6D2D

2D

2D 2D

2D

4D 4D 4D 4D 4D

ELEV

NORTH

STAIR

NORTH

CLASSROOM

CLASSROOM

106A

CLASSROOM

106B

CLASSROOM

107A

CLASSROOM

107B

CLASSROOM

CONFERENCE

CORRIDOR

4D 4D 4D 4D 4DAV

4D 4D 4D 4D 4DAV

AV

4D 4D 4D 4D 4D

4D 4D 4D 4D 4D

AV

AV

"D x

"W "D x

"W

4"D x 12"W

TRAILER

LOT

B61

N

KEY PLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

KS

KS

ARCH REG. NO.

ENGR REG. NO.

EXP. 12/31/2023

EXP. 12/31/2023

A-930, E-2586, CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

PLUMBING ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER

SPUR #: 1794.08

SPUR #: 1794.08

-J a n -2

:2

:0

B61, FIRST LEVEL - TECHNOLOGY PLAN

MIJ 85 88BEN

ISSUED FOR CONSTRUCTION

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

ADMINISTRATIVE SPACE

01/28/2022

589A7-21-702

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

TN102

N

1/8" = 1'-0"

B61, FIRST LEVEL - TECHNOLOGY PLAN1

AREA OF WORK

TECHNOLOGY KEYNOTES

17 PROVIDE 2" CONDUIT TO LOCATION OF TV.

18 EXISTING DATA RACKS TO REMAIN. PROVIDE ADDITIONAL PATCH PANELS AS REQUIRED.

20 MAINTAIN FIREPROOF RATING FOR WALL PENETRATION.

CR

EL

LO NG TERMADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICACUTE INPATIENTAM BULATO RY

LO NG TERM

ADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICM ENTAL HEALTHACUTE INPATIENTAM BULATO RYM ENTAL HEALTH

A

B C D E F G

STAIR

NORTH

CLASSROOM

002B

BREAK

006B

OFFICE

001D

OFFICE

CORRIDOR

001-2

CORRIDOR

001-3

TOILET (M)

TOILET (W)

CLASSROOM

005A

CLASSROOM

004A

CLASSROOM

003B

WAITING

006A

COFFEE

ELEC

001B

CLASSROOM

002A CLASSROOM

003A

CLASSROOM

004B

CLASSROOM

005B

ALCOVE

STOR.

001C

OFFICE

001A

WAITING

001E

CORRIDOR

001-1

ELECTRICAL

SECURITY

PANEL

LLGB (ETR)

LHG (ETR)

TRAILER

LOT

B61

N

KEY PLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

KS

KS

ARCH REG. NO.

ENGR REG. NO.

EXP. 12/31/2023

EXP. 12/31/2023

A-930, E-2586, CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

PLUMBING ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER

SPUR #: 1794.08

SPUR #: 1794.08

-J a n -2

:2

:0

B61, GROUND LEVEL - SECURITY PLAN

MIJ 86 88BEN

ISSUED FOR CONSTRUCTION

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

ADMINISTRATIVE SPACE

01/28/2022

589A7-21-702

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

TY101

N

1/8" = 1'-0"

B61, GROUND LEVEL - SECURITY PLAN1

AREA OF WORK

ELECTRICAL KEYNOTES

11 NEW C-CURE (16 DOOR PANEL). PROVIDE NEW SWITCH AND TIE INTO FIBER NETWORK (OM1).

CR

CR

CR CR

CR

CR

ELEL

EL

EL

EL

EL

EL

EL

LO NG TERMADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICACUTE INPATIENTAM BULATO RY

LO NG TERM

ADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICM ENTAL HEALTHACUTE INPATIENTAM BULATO RYM ENTAL HEALTH

C D E F G

SECURITY

PANEL

CLASSROOM

CLASSROOM

106A

CLASSROOM

106B

CLASSROOM

107A

CLASSROOM

107B

CLASSROOM

CONFERENCE

CORRIDOR

TRAILER

LOT

B61

N

KEY PLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

KS

KS

ARCH REG. NO.

ENGR REG. NO.

EXP. 12/31/2023

EXP. 12/31/2023

A-930, E-2586, CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

PLUMBING ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER

SPUR #: 1794.08

SPUR #: 1794.08

-J a n -2

:2

:0

B61, FIRST LEVEL - SECURITY PLAN

MIJ 87 88BEN

ISSUED FOR CONSTRUCTION

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

ADMINISTRATIVE SPACE

01/28/2022

589A7-21-702

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

TY102

N

1/8" = 1'-0"

B61, FIRST LEVEL - SECURITY PLAN1

AREA OF WORK

ELECTRICAL KEYNOTES

11 NEW C-CURE (16 DOOR PANEL). PROVIDE NEW SWITCH AND TIE INTO FIBER NETWORK (OM1).

CAT 5E

NOTE:

COORDINATE EXACT LOCATION OF OUTLET WITH ARCHITECTURAL PLANS. LOCATION OF

OUTLET SHALL NOT CONFLICT WITH MOUNTING BRACKETS OR OTHER TRADES. PERMANENTLY

LABEL ALL WALL JACKS IN THE FOLLOWING MANNER: BUILDING-FLOOR-JACK NUMBER-ROOM

NUMBER OF CLOSET. EXAMPLE: 1-1-33-148B (BUILDING 1, FLOOR 1, JACK 33, CLOSET ROOM

NUMBER 148B). JACK NUMBER INDICATES THE PUNCH DOWN POSITION OF THE CLOSET

CONNECTION. ALL JACKS ON THE SAME PLATE SHALL HAVE THE SAME NUMBER WHERE

POSSIBLE.

PROVIDE INSULATING

BUSHING ON ALL PATHWAYS

TO COMMUNICATIONS

BACKBOXES.

PROVIDE CATEGORY 5E, 8P8C

CONNECTOR FOR DATA

CONNECTION "1B". COLOR OF

CABLE AND CONNECTOR IS BLUE.

TERMINATE DATA CABLE IN TR AT

RACK-MOUNTED 48-PORT

MODULAR PATCH PANELS.

PROVIDE COAX

F-CONNECTOR. MATCH

ADAPTER COLOR TO

FACEPLATE.

PROVIDE SINGLE-GANG,

2-PORT FACEPLATE WITH

IDENTIFICATION WINDOWS.

PROVIDE 1" RACEWAY,

UNLESS NOTED OTHERWISE.

PROVIDE INSULATION

BUSHING AT ENTRANCE TO

BACKBOX.

PROVIDE DOUBLE-GANG

BACKBOX WITH

SINGLE-GANG PLASTER

RING.

1 2

3 4

NOTE:

PERMANENTLY LABEL ALL WALL JACKS IN THE FOLLOWING MANNER: BUILDING-FLOOR-JACK

NUMBER-ROOM NUMBER OF CLOSET. EXAMPLE: 1-1-33-148B (BUILDING 1, FLOOR 1, JACK 33, CLOSET ROOM NUMBER 148B). JACK NUMBER INDICATES THE PUNCH DOWN POSITION OF THE

CLOSET CONNECTION. ALL JACKS ON THE SAME PLATE SHALL HAVE THE SAME NUMBER

WHERE POSSIBLE.

PROVIDE INSULATING

BUSHING ON ALL PATHWAYS

TO COMMUNICATIONS

BACKBOXES.

PROVIDE CATEGORY 5E,

8P8C CONNECTOR FOR DATA

CONNECTION "1A". COLOR

OF CABLE IS GRAY, COLOR

OF CONNECTOR IS ORANGE.

TERMINATE ALL DATA

CABLES IN TR AT

RACK-MOUNTED 48-PORT

MODULAR PATCH PANELS.

PROVIDE CATEGORY 5E, 8P8C

CONNECTOR FOR DATA

CONNECTION "1B". COLOR OF

CABLE IS GRAY, COLOR OF

CONNECTOR IS RED. TERMINATE

ALL DATA CABLES IN TR AT

RACK-MOUNTED 48-PORT

MODULAR PATCH PANELS.

PROVIDE CATEGORY 5E,

8P8C CONNECTOR FOR

VOICE CONNECTION "V1".

COLOR OF CABLE IS BLUE,

COLOR OF CONNECTOR IS

BLUE. TERMINATE ALL VOICE

CABLES IN TR AT

RACK-MOUNTED 48-PORT

MODULAR PATCH PANELS.

PROVIDE SINGLE-GANG,

6-PORT FACEPLATE WITH

IDENTIFICATION WINDOWS.

PROVIDE 1-1/4" RACEWAY,

UNLESS NOTED OTHERWISE.

PROVIDE INSULATION

BUSHING AT ENTRANCE TO

BACKBOX.

PROVIDE 4-11/16" X 4-11/16" X

2-1/8" DOUBLE-GANG

BACKBOX WITH SINGLE-GANG

PLASTER RING.

FILL ALL UNUSED PORTS

WITH BLANK INSERTS. MATCH

COLOR OF FACEPLATE. (TYP.)

DOOR POSITION

SWITCH

ACCESSIBLE CEILING

PROVIDE DOUBLE-GANG

BACKBOX WITH SINGLE-GANG

PLASTER RING FOR DOOR

MOTION DETECTOR.

LOCATION PER PLANS.

3/4" CONDUIT

(TYPICAL, UNO)

ELECTRIFIED

LOCKSET/STRIKE

DOOR

PROVIDE 6"X6"X4" DEEP

JUNCTION BOX WITH

HINGED COVER.

LOCATE ON SECURE

SIDE OF DOOR.

PROVIDE 1" CONDUIT

BACK TO ACCESS

CONTROL PANEL.

PROVIDE DOUBLE-GANG

BACKBOX WITH

SINGLE-GANG PLASTER

RING FOR CARD READER.

LOCATION PER PLANS.

FLOOR

MAX. 48" AFF

OR MATCH

LIGHT SWITCH

U S

B

H D

M I

VGA

PROVIDE COAX CABLING PER

SPECIFICATIONS WITH COAX

F-CONNECTOR AND CABLE BACK

TO HEAD-END CATV SYSTEM.

PROVIDE HORIZONTAL CABLING

PER SPECIFICATIONS WITH RJ45

CONNECTOR FOR DATA

CONNECTION. TERMINATE CABLE

IN TR AT RACK-MOUNTED

48-PORT MODULAR PATCH PANEL.

FILL ALL UNUSED PORTS WITH

BLANK ADAPTERS.

PROVIDE COMPOSITE

ADAPTER/COMPONENT AV ADAPTER.

COORDINATE WITH COR FOR

CONNECTIVITY REQUIREMENTS AT

EACH MONITOR/AV DEVICE.

PROVIDE INSULATING

BUSHING ON ALL PATHWAYS

TO COMMUNICATIONS

BACKBOXES.

PROVIDE MINIMUM 1-1/4" RACEWAY,

FOR DATA AND CATV CABLING.

PROVIDE 2" RACEWAY FROM

BACKBOX TO TELEVISION MOUNT.

COORDINATE LOCATION WITH

OWNER.

PROVIDE THREE-GANG, 3.5" DEEP

BACKBOX WITH DOUBLE-GANG

PLASTER RING.

PROVIDE S-VIDEO

FEED-THROUGH CONNECTOR

AND 3.5MM AUDIO ADAPTER.

PROVIDE HDMI AND USB

FEED-THROUGH ADAPTERS.

PROVIDE SINGLE-GANG,

2-PORT FACEPLATE WITH

IDENTIFICATION WINDOWS.

NOTE:

COORDINATE EXACT LOCATION OF OUTLET WITH ARCHITECTURAL PLANS. LOCATION OF

OUTLET SHALL NOT CONFLICT WITH MOUNTING BRACKETS OR OTHER TRADES. PERMANENTLY

LABEL ALL WALL JACKS IN THE FOLLOWING MANNER: BUILDING-FLOOR-JACK NUMBER-ROOM

NUMBER OF CLOSET. EXAMPLE: 1-1-33-148B (BUILDING 1, FLOOR 1, JACK 33, CLOSET ROOM

NUMBER 148B). JACK NUMBER INDICATES THE PUNCH DOWN POSITION OF THE CLOSET

CONNECTION. ALL JACKS ON THE SAME PLATE SHALL HAVE THE SAME NUMBER WHERE

POSSIBLE.

PROVIDE VGA

FEED-THROUGH ADAPTER.

CAT 5E

CAT 6A

NOTE:

COORDINATE EXACT LOCATION OF OUTLET WITH ARCHITECTURAL PLANS. LOCATION OF

OUTLET SHALL NOT CONFLICT WITH MOUNTING BRACKETS OR OTHER TRADES. PERMANENTLY

LABEL ALL WALL JACKS IN THE FOLLOWING MANNER: BUILDING-FLOOR-JACK NUMBER-ROOM

NUMBER OF CLOSET. EXAMPLE: 1-1-33-148B (BUILDING 1, FLOOR 1, JACK 33, CLOSET ROOM

NUMBER 148B). JACK NUMBER INDICATES THE PUNCH DOWN POSITION OF THE CLOSET

CONNECTION. ALL JACKS ON THE SAME PLATE SHALL HAVE THE SAME NUMBER WHERE

POSSIBLE.

PROVIDE INSULATING

BUSHING ON ALL PATHWAYS

TO COMMUNICATIONS

BACKBOXES.

PROVIDE CATEGORY 5E, 8P8C

CONNECTOR FOR DATA

CONNECTION "1B". COLOR OF

CABLE AND CONNECTOR IS BLUE.

TERMINATE DATA CABLE IN TR AT

RACK-MOUNTED 48-PORT

MODULAR PATCH PANELS.

PROVIDE SINGLE-GANG,

2-PORT FACEPLATE WITH

IDENTIFICATION WINDOWS.

PROVIDE 1" RACEWAY,

UNLESS NOTED OTHERWISE.

PROVIDE INSULATION

BUSHING AT ENTRANCE TO

BACKBOX.

PROVIDE DOUBLE-GANG

BACKBOX WITH

SINGLE-GANG PLASTER

RING.

CAT 6A

CR

DM

EL

RE

CATEGORY 6 CABLE

MULTI-CONDUCTOR CABLE

2-STRAND FIBER-OPTIC PATCH CABLE

POWER

PB

LEGEND:

120VELECTRICAL

FIRE ALARM

RELAY(S)

PACS BATTERY

CABINET(S)

PHYSICAL

ACCESS

CONTROL

CABINET(S)

COORDINATE

CONNECTION TO FIBER

ENCLOSURE WITH VA

OI&T

CARD READERS AND

ASSOCIATED DEVICES PER

PLANS. (TYPICAL)

FIRST FLOORROOM 011

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

KS

KS

ARCH REG. NO.

ENGR REG. NO.

EXP. 12/31/2023

EXP. 12/31/2023

A-930, E-2586, CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

PLUMBING ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER

SPUR #: 1794.08

SPUR #: 1794.08

-J a n -2

:2

:0

TECHNOLOGY DETAILS AND LEGENDS

MIJ 88 88BEN

ISSUED FOR CONSTRUCTION

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

ADMINISTRATIVE SPACE

01/28/2022

589A7-21-702

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

T-500

NTS

TELEVISION OUTLET DETAIL1

NTS

TELECOMMUNICATIONS OUTLET DETAIL2NTS

TYPICAL CARD READER SYSTEM DETAIL5

NTS

AUDIO/VISUAL WORK AREA OUTLET DETAIL3

NTS

WIRELESS ACCESS POINT DETAIL4

1. PROVIDE ALL ACCESSORIES AS REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM COMPATIBLE WITH THE EXISTING CAMPUS PACS SYSTEM. PROVIDE ALL UPGRADES TO THE EXISTING PACS SYSTEM TO INCORPORATE NEW DEVICES.

NOTES:

PHYSICAL ACCESS CONTROL SYSTEM (PACS) CARD READER SCHEDULE

TYPE

SYMBOL

TYPE

DESCRIPTION MOUNTING

MOUNTING

HEIGHT

LOCATION MODELS READ RANGE POWER COLOR COMMENTS NOTES

CR-01 CARD READER

WALL, RE: DETAIL

8/165-T-501

48" TO TOP OF

BOX ABOVE

FINISHED

FLOOR

INDOOR/OUTD

OOR

MATCH EXISTING

VA CARD READER

SYSTEM

4" MAXIMUM

85mA AVG/ 116mA PEAK AT

12VDC

BLACK

DUAL AUTHNTICATION CARD READER WITH KEYPAD

COMPATIBLE WITH C-CURE SECURITY PANEL.

NTS

SECURITY RISER DIAGRAM6

81_T-000_TECHNOLOGY LEGEND, NOTES AND ABBREVIATIONS
82_TD101_B61, GROUND LEVEL -TECHNOLOGY DEMOLITION PLAN
83_TD102_B61, FIRST LEVEL -TECHNOLOGY DEMOLITION PLAN
84_TN101_B61, GROUND LEVEL -TECHNOLOGY PLAN
85_TN102_B61, FIRST LEVEL -TECHNOLOGY PLAN
86_TY101_B61, GROUND LEVEL -SECURITY PLAN
87_TY102_B61, FIRST LEVEL -SECURITY PLAN
88_T-500_TECHNOLOGY DETAILS AND LEGENDS

File details come from the government source that posted it. Updated .