This solicitation seeks a general contractor to complete renovations at the Robert J. Dole VA Medical Center in Wichita, Kansas. The project involves renovating approximately 12,000 square feet on the ground level of Building 61 to create training and administrative support space. Renovations will include demolition, new partitions, finishes, fixtures and equipment. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas. Responses are due on the date specified in the solicitation. The selected contractor will be responsible for providing all labor, materials and equipment to complete the project in accordance with the drawings and specifications.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT SCOPE AREA
BUILDING 61, GROUND AND LEVEL 1
29 26
3 1
1C
19 2
1B
10 11 16
121320
5B
TOTAL PARKING:
22 SPACES
32.01
3.13
32.02
10.31
5.29
5.30
PROJECT SCOPE AREA
NEW PARKING LOT WITH
UTILITY HOOKUPS FOR
TEMPORARY TRAILERS
REFERENCE CIVIL, MECHANICAL AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION.
3.14
33.01
SCOPE BOUNDARY
25'-0" SAFETY SETBACK
EXISTING BUILDING FOOTPRINT
PAVEMENT STRIPING
EXISTING BUILDING FOOTPRINT
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:5
P
M
ARCHITECTURAL SITE PLAN
JLJ 16 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AS100
N
1" = 50'-0"
ARCHITECTURAL SITE PLAN1
KEYNOTE LEGEND
3.13 PRECAST WHEEL STOP
3.14 CONCRETE PAD FOR NEW TRAILER LOCATION. REFERENCE CIVIL FOR MORE INFORMATION.
5.29 PREFABRICATED RAMP
5.30 PREFABRICATED PLATFORM
10.31 CERNER PROVIDED TRAILER
32.01 PAVEMENT STRIPING
32.02 ADA PARKING SIGNAGE
No. REVISION DESCRIPTION DATE
UP
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE
UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OT AREA HAS
BEEN INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL COORDINATOR
AND THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND
MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR
DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE
PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR
PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO
BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER
9. WHERE REMOVAL OF A MATERIAL IS CALLED FOR, THE ENTIRE SYSTEM SHALL BE REMOVED
UNLESS INDICATED OTHERWISE
10. EXISTING FURNITURE REMOVAL TO BE COORDINATED WITH VA COR PRIOR TO START OF
CONSTRUCTION
GENERAL DEMOLITION NOTES
AREA IS NOT IN CONTRACT
EXISTING WALLS
TO REMAIN
EXISTING DOOR AND FRAME
TO REMAIN
X.XX KEYNOTE; REFERENCE KEYNOTE LEGEND
EXISTING WALLS
TO BE DEMOLISHED
EXISTING DOOR AND FRAME
TO BE DEMOLISHED
DEMOLITION PLAN LEGEND
ICRA BARRIER PER ICRA MATRIX OF PRECAUTIONS.
REFER TO AE021 FOR WALL CONSTRUCTION.
A
B C D E F G
ELEV
NORTH
STAIR
NORTH
ELEV
SOUTH
STAIR
SOUTH
2.21
2.21
2.21 2.21
2.21
2.21
2.21
2.21
2.312.31
2.312.31
2.31
2.31
2.31
2.31
2.21
9' -6
/4
5'
-7
3' -4
7'
-5
/4
VETERANS BENEFIT
SERVICE
OFFICE
005E
OFFICE
005A
OFFICE
OFFICE
RESTROOM
RESTROOM
STORAGE
004A
OFFICE
005B
OFFICE
008D
KITCHENETTE
008E
REGIONAL OFFICE
DIRECTOR
008A
DIRECTOR'S OFFICE
008G
1'-4"
OFFICE
CONFERENCE ROOM
008F
OFFICE
008C
FISCAL SERVICE
DIRECTOR
OFFICE
008C
OFFICE
020E
OFFICE
020D
OFFICE
020C
OFFICE
020B
OFFICE
020A
VESTIBULE
020-61
BREAK
020G
AFGE UNION OFFICE
011A
UNION OFFICE
CENTEEN STORAGE
009-61
ELECTRICAL
LOADING DOCK
CORRIDOR
CORR
MECHANICAL ROOM
CORRIDOR
SERVER ROOM
015B
IRM
STOR
015A
HAC
RESTROOM
RESTROOM
ELEVATOR ROOM
COMPUTER LAB
2.32
2.32
2.322.32
2.32
2.32
2.32
2.32
2.32
2.32
2.32
2.32
2.33
2.33
2.33
2.33
2.33
2.33
2.33
2.33
2.33
2.33
2.33
2.332.33
2.33
2.33
2.33
2.34
2.34
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
FV
20'-0"
FV
26'-0" FV
133'-0"
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
6'
-0
2.30
2.34
1' -0
TELECOM
008A
ELEV CONTROL
BUILDING 61 KEY PLAN - GROUND FLOOR
PHASE 2
RENOVATED
TRAINING AND
OFFICE SPACE
N
PHASE 2
RENOVATED
OFFICE SPACE
OUT OF SCOPE
PHASE 1
RESTROOMS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:0
P
M
B61, GROUND LEVEL - DEMOLITION FLOOR
PLAN
JLJ 17 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AD100
N
1/8" = 1'-0"
BUILDING 61 - GROUND LEVEL - DEMOLITION FLOOR PLAN1
KEYNOTE LEGEND
2.21 DEMOLISH EXISTING PLUMBING FIXTURE. REFERENCE PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
2.30 DEMOLISH COLUMN WRAP AND CORNER-GUARDS IF PRESENT
2.31 EXISTING COLUMN WRAP TO BE PATCHED AND REPAIRED WHERE ABUTTING WALL IS
DEMOLISHED
2.32 REMOVE ALL EXISTING FLOORING AND WALL BASE. PREPARE SURFACE FOR NEW FINISH.
2.33 REMOVE WINDOW SHADE BRACKET AT EXISTING WINDOWS WITHIN SCOPE.
2.34 PROVIDE REQUIRED INFECTION CONTROL PRECAUTIONS (CLASS II) DURING CONSTRUCTION AS
STATED IN THE ICRA MATRIX OF PRECAUTIONS FOR CONSTRUCTION AND RENOVATION.
LOCATION AND QUANTITY OF BARRIER CONTROL TO BE DETERMINED BY THE CONTRACTOR.
C D E F G
CORRIDOR
VFW
VETERAN'S OF AMERICA
PARALYZED OFFICE
KANSAS COMMISSION
VETERAN'S AFFAIRS
QUALITY ASSURANCE
TLT
TLT
S T
O R
A G
E
E L
E C
T
VESTIBULE
OFFICE
103B
OFFICE
103A
HEARING ROOM
OFFICE
103C
OFFICE
103D
OFFICE
103F
OFFICE
103E
OFFICE
OFFICE
110E
REHABILITATION
VOCATIONAL
OFFICE
110A
REHAB CHIEF
110B
CONSULTING
110C
CONSULTING
110D
OFFICE
110F
OFFICE
110G
2.32
2.33
2.32
2.32
2.32
2.33
2.32
2.33
2.32
2.33
2.33
2.322.322.32
2.332.332.33 2.322.322.32
2.32
2.32 2.32 2.32
2.34
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
0'
-0
FV
87'-0"
STAIR
NORTH
ELEV
NORTH
AREA IS NOT IN CONTRACT
EXISTING WALLS
TO REMAIN
EXISTING DOOR AND FRAME
TO REMAIN
X.XX KEYNOTE; REFERENCE KEYNOTE LEGEND
EXISTING WALLS
TO BE DEMOLISHED
EXISTING DOOR AND FRAME
TO BE DEMOLISHED
DEMOLITION PLAN LEGEND
ICRA BARRIER PER ICRA MATRIX OF PRECAUTIONS.
REFER TO AE021 FOR WALL CONSTRUCTION.
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE
UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OT AREA HAS
BEEN INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL COORDINATOR
AND THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND
MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR
DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE
PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR
PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO
BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER
9. WHERE REMOVAL OF A MATERIAL IS CALLED FOR, THE ENTIRE SYSTEM SHALL BE REMOVED
UNLESS INDICATED OTHERWISE
10. EXISTING FURNITURE REMOVAL TO BE COORDINATED WITH VA COR PRIOR TO START OF
CONSTRUCTION
GENERAL DEMOLITION NOTES
BUILDING 61 KEY PLAN - FIRST FLOOR
PHASE 1
RENOVATED
TRAINING AND
OFFICE SPACE
NOUT OF SCOPE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:0
P
M
B61, LEVEL 1 - DEMOLITION FLOOR PLAN
JLJ 18 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AD101
N
1/8" = 1'-0"
BLDG 61 - LEVEL 1 - DEMOLITION FLOOR PLAN1
KEYNOTE LEGEND
2.32 REMOVE ALL EXISTING FLOORING AND WALL BASE. PREPARE SURFACE FOR NEW FINISH.
2.33 REMOVE WINDOW SHADE BRACKET AT EXISTING WINDOWS WITHIN SCOPE.
2.34 PROVIDE REQUIRED INFECTION CONTROL PRECAUTIONS (CLASS II) DURING CONSTRUCTION
AS STATED IN THE ICRA MATRIX OF PRECAUTIONS FOR CONSTRUCTION AND RENOVATION.
LOCATION AND QUANTITY OF BARRIER CONTROL TO BE DETERMINED BY THE CONTRACTOR.
EXISTING EXIT LIGHT
EXISTING CEILING GRID AND TILE
TO BE DEMOLISHED
EXISTING LIGHT FIXTURE
TO BE DEMOLISHED
EXISTING RETURN AIR GRILLE
EXISTING SUPPLY AIR DIFFUSER
EXISTING EXHAUST AIR GRILLE
AREA NOT IN CONTRACT
X.XX KEYNOTE; REFERENCE KEYNOTE LEGEND
DEMOLITION CEILING PLAN LEGEND
A
B C D E F G
VETERANS BENEFIT
SERVICE
OFFICE
005E
OFFICE
005A
OFFICE
OFFICE
RESTROOM
RESTROOM
STORAGE
004A
OFFICE
005B
OFFICE
008D
KITCHENETTE
008E
REGIONAL OFFICE
DIRECTOR
008A
DIRECTOR'S OFFICE
008G
TELECOM
OFFICE
CONFERENCE ROOM
008F
OFFICE
008C
FISCAL SERVICE
DIRECTOR
OFFICE
008C
OFFICE
020E
OFFICE
020D
OFFICE
020C
OFFICE
020B
OFFICE
020A
VESTIBULE
020-61
BREAK
020G
AFGE UNION OFFICE
011A
UNION OFFICE
CENTEEN STORAGE
009-61
ELECTRICAL
LOADING DOCK
CORRIDOR
CORR
MECHANICAL ROOM
CORRIDOR
SERVER ROOM
015B
IRM
STOR
015A
HAC
RESTROOM
RESTROOM
ELEVATOR ROOM
CORRIDOR
COMPUTER LAB
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
FV
20'-0"
FV
26'-0"
FV
133'-0"
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
6'
-0
ELEV CONTROL
CORRIDOR
ELEV
NORTH
STAIR
NORTH
ELEV
SOUTH
STAIR
SOUTH
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE
UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OT AREA HAS
BEEN INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL
COORDINATOR AND THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY
DAMAGE CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND
MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR
DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE
PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR
PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO
BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER
9. REMOVE ALL EXISTING WINDOW TREATMENTS
10. WHERE REMOVAL OF A MATERIAL IS CALLED FOR, THE ENTIRE SYSTEM SHALL BE REMOVED
UNLESS INDICATED OTHERWISE
11. GENERAL CONTRACTOR TO COORDINATE EXISTING SPRINKLER HEAD LOCATIONS TO REMAIN
AND BE RELOCATED IN NEW CEILINGS
GENERAL REFLECTED CEILING PLAN DEMOLITION NOTES
BUILDING 61 KEY PLAN - GROUND FLOOR
PHASE 2
RENOVATED
TRAINING AND
OFFICE SPACE
N
PHASE 2
RENOVATED
OFFICE SPACE
OUT OF SCOPE
PHASE 1
RESTROOMS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:1
P
M
B61, GROUND LEVEL - DEMOLITION CEILING
PLAN
DLB 19 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AD200
N
1/8" = 1'-0"
BUILDING 61 - GROUND LEVEL - DEMOLITION CEILING PLAN1
C D E F G
CORRIDOR
VFW
VETERAN'S OF AMERICA
PARALYZED OFFICE
KANSAS COMMISSION
VETERAN'S AFFAIRS
QUALITY ASSURANCE
TLT
TLT
S T
O R
A G
E
E L
E C
T
VESTIBULE
OFFICE
103B
OFFICE
103A
HEARING ROOM
OFFICE
103C
OFFICE
103D
OFFICE
103F
OFFICE
103E
OFFICE
OFFICE
110E
REHABILITATION
VOCATIONAL
OFFICE
110A
REHAB CHIEF
110B
CONSULTING
110C
CONSULTING
110D
OFFICE
110F
OFFICE
110G
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
0'
-0
FV
87'-0"
AE200
STAIR
NORTH
ELEV
NORTH
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE
UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OT AREA HAS
BEEN INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL
COORDINATOR AND THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY
DAMAGE CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND
MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR
DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE
PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR
PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO
BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER
9. REMOVE ALL EXISTING WINDOW TREATMENTS
10. WHERE REMOVAL OF A MATERIAL IS CALLED FOR, THE ENTIRE SYSTEM SHALL BE REMOVED
UNLESS INDICATED OTHERWISE
11. GENERAL CONTRACTOR TO COORDINATE EXISTING SPRINKLER HEAD LOCATIONS TO REMAIN
AND BE RELOCATED IN NEW CEILINGS
GENERAL REFLECTED CEILING PLAN DEMOLITION NOTES
EXISTING EXIT LIGHT
EXISTING CEILING GRID AND TILE
TO BE DEMOLISHED
EXISTING LIGHT FIXTURE
TO BE DEMOLISHED
EXISTING RETURN AIR GRILLE
EXISTING SUPPLY AIR DIFFUSER
EXISTING EXHAUST AIR GRILLE
AREA NOT IN CONTRACT
X.XX KEYNOTE; REFERENCE KEYNOTE LEGEND
DEMOLITION CEILING PLAN LEGEND
BUILDING 61 KEY PLAN - FIRST FLOOR
PHASE 1
RENOVATED
TRAINING AND
OFFICE SPACE
NOUT OF SCOPE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:1
P
M
B61, LEVEL 1 - DEMOLITION CEILING PLAN
JLJ 20 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AD201
N
1/8" = 1'-0"
B61, LEVEL 1 - DEMOLITION CEILING PLAN1
BASE
PLAN
HEAD
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE (REF: ROOM FINISH SCHEDULE)
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
WIDTH
STUD3/4"
WIDTH
ACTUAL
BATT INSULATION WHERE
SPECIFIED IN SCHEDULE
DIM DIM
METAL STUD PER SCHEDULE
5/8" GYPSUM BOARD
METAL STUD U-TRACK (TOP AND BOTTOM)
BASE
PLAN
HEAD
UNDERSIDE OF STRUCTURE
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
3/4"TYPE X
WIDTH
STUD 3/4"TYPE X
5/8" "TYPE X" GYPSUM BOARD
EACH SIDE
FINISH FLOOR
(REF: ROOM FINISH SCHEDULE)
BASE (REF: ROOM FINISH SCHEDULE)
METAL STUD PER SCHEDULE
FIRE RATED SEALANT AROUND PERIMETER
BATT INSULATION
FIRE RATED SEALANT
AROUND PERIMETER
DIM DIM
METAL STUD U-TRACK (TOP AND BOTTOM)
BASE
PLAN
HEAD
METAL STUD U-TRACK (TOP AND BOTTOM)
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
3/4"
WIDTH
STUD 3/4"
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE - (REF: ROOM FINISH SCHEDULE)
BATT INSULATION WHERE
SPECIFIED IN SCHEDULE
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
NOTE: INSULATED WALLS AROUND
RESTROOMS EXTEND OUTSIDE LAYER
OF GYPSUM BOARD TO DECK
DIM DIM
METAL STUD PER SCHEDULE
BASE
PLAN
HEAD
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
EXTRUDED ALUMINUM BASE TRACK WITH CARPET
GRIPPER AND LEVELER ASSEMBLY
CAVITY FOR ELECTRICAL CONDUIT AND
FACTORY INSULATION
DIM DIM
CHROMA COAT PAINTED TILES REFER FINISH SCHEDULE
CEILING TRACK
A3
BASIC PARTITION
ASSEMBLY CATEGORY
FRAMING UNIT
SIZE CATEGORY
PARTITION TAG
PARTITION
PER PLAN
TYPICAL PARTITION TAG
BASE
PLAN
HEAD
METAL STUD U-TRACK (TOP AND BOTTOM)
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
5/8"
WIDTH
STUD 5/8"
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE - (REF: ROOM FINISH SCHEDULE)
FIRE-RATED SEALANT AROUND
PERIMETER (INSULATED WALLS)
DIM DIM
METAL STUD PER SCHEDULE
UNDERSIDE OF STRUCTURE
BASIS OF DESIGN: DIRRT DEMOUNTABLE WALL OR EQUAL
EXTRUDED ALUMINIUM TOP HORIZONTAL FRAME
BASE TRIM
BOTTOM HORIZONTAL FRAMEINSULATE BASE
CAVITY IN FEILD
1. NOT ALL PARTITION TYPES SHOWN HERE MAY BE USED. REFER TO PLANS FOR LOCATION AND
TYPES OF EACH PARTITION.
2. PAINT CONTINUOUS 4" TALL, STENCILED LETTERS, ABOVE CEILING, ON BOTH SIDES OF ALL FIRE AND SMOKE WALLS DESIGNATING THE PARTITION RATING INDICATED ON THE LIFE SAFETY PLAN.
3. REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR LOCATIONS OF ALL WALL TILE.
PROVIDE AND INSTALL CEMENTITIOUS BACKER BOARD IN LIEU OF GWB AT ALL SCHEDULED TILE
LOCATIONS. UNLESS NOTED OTHERWISE, TILE SHALL BE INSTALLED PER TILE COUNCIL OF
AMERICA LATEST STANDARDS FOR EACH TYPE OF BACKING MATERIAL REPRESENTED IN
WALL/PARTITION.
4. ALL SUSPENDED WALLS AND PARTITIONS SHALL HAVE GWB WHICH EXTENDS A MINIMUM OF 6"
ABOVE THE SUSPENDED CEILING UNLESS SHOWN AND/OR NOTED OTHERWISE BY THE
ARCHITECT.
5. REFER TO STRUCTURAL DRAWINGS FOR ALL LOAD BEARING WALL CONDITIONS IN REGARDS TO
STRUCTURAL REQUIREMENTS.
6. "ALIGN" MEANS SIMILAR COMPONENTS OF CONSTRUCTION, E.G. WALLS, JAMBS, ETC. SHALL
ALIGN ACROSS VOIDS AND JOINTS.
7. PARTITIONS SHALL BE CONTINUOUS OVER DOORS SAME ADJACENT WALLS (UNLESS NOTED
OTHERWISE) WHERE GYPSUM BOARD CONTINUES ABOVE CEILING AND ABOVE THE CEILING
LEVEL UP TO THE STRUCTURE ABOVE. ALL GYPSUM BOARD RETURNS SHALL HAVE CORNER
BEADS MINIMUM FLOOR TO CEILING. ALL PENETRATIONS IN GYPSUM BOARD CONSTRUCTION
ABOVE FINISHED CEILING SHALL BE EFFECTIVELY SEALED TO PREVENT SOUND LEAKAGE AND
FIRE STOPPING TAPE/CAULK AT ALL RATED PARTITIONS.
8. ALL MECHANICAL CHASES AND OTHER NOTED CHASES ARE TO EXTEND UP TO THE UNDERSIDE
OF THE DECK STRUCTURE ABOVE. ALL PLUMBING CHASES UNLESS NOTED OTHERWISE, SHALL
EXTEND ABOVE THE HIGHEST ADJOINING CEILING AND BE BRACED TO STRUCTURE.
9. ALL CONSTRUCTION DESIGNATED TO BE SUPPORTED BY ROOF STRUCTURE SHALL BE
SUPPORTED BY TOP CHORD OF STRUCTURAL JOISTS AND NOT FROM THE METAL DECK.
10. COORDINATE WITH MILLWORK DRAWINGS FOR PLACEMENT OF BLOCKING IN WALLS/PARTITIONS.
ALL WOOD BLOCKING IS TO BE FIRE RETARDANT TREATED.
11. IMPACT RESISTANT GWB, WHERE NOTED, IS OPTIONAL ABOVE 8' AFF AND BEHIND LOCKERS.
12. SEAL THE TOP AND BOTTOM OF WALL AS WELL AS ALL PENETRATIONS WHERE SMOKE
PARTITIONS ARE DESIGNATED ON THE LIFE SAFETY PLAN TO ELIMINATE THE PASSAGE OF
SMOKE.
13. USE DEFLECTION TRACKS WHERE STUD WALLS ATTACH DIRECTLY TO METAL DECK.
GENERAL PARTITION NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:1
P
M
PARTITION TYPES
JLJ 21 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AE021
PARTITION TYPES
MARK TYPE STC DESCRIPTION WIDTH
X1
NON-INSULATED /
ICRA
-- 5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD
4 7/8"
PARTITION TYPES
MARK TYPE STC DESCRIPTION WIDTH
R1 INSULATED -- DEMOUNTABLE WALL (VA PROVIDED / VA INSTALLED) 6"
PARTITION TYPES
MARK TYPE STC DESCRIPTION WIDTH
H3 1 HR / SMOKE (U419) 49 5/8" TYPE X GYPSUM BOARD ON EACH SIDE OF 3 5/8" METAL STUD. 4 7/8"
PARTITION TYPES
MARK TYPE STC DESCRIPTION WIDTH
C3 NON-INSULATED -- 5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD 4 7/8"
D3 INSULATED (U419)
45 5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD W/ BATT
INSULATION
4 7/8"
D6 INSULATED -- 5/8" GYPSUM BOARD EACH SIDE OF 6" METAL STUD W/ BATT INSULATION 7 1/4"
PARTITION TYPES
MARK TYPE STC DESCRIPTION WIDTH
A3 NON-INSULATED -- 5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL STUD 4 1/4"
A4 NON-INSULATED -- 5/8" GYPSUM BOARD ONE SIDE 7/8" HAT CHANNEL 2"
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF
ADJACENT WALL UNLESS NOTED OTHERWISE.
2. ALL WALLS ARE TYPE D3 PARTITIONS UNLESS NOTED OTHERWISE. REFER TO PARTITION TYPE
SHEET FOR WALL TYPES.
3. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.
4. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.
5. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW
TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.
6. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.
7. ANY CONSTRUCTION ACTIVITY THAT IMPACTS THE FIRE OR SMOKE RATING OF EXISTING
WALLS SHALL BE PROPERLY REPAIRED AND FIRESTOPPED AS REQUIRED TO MAINTAIN THE
EXISTING RATING.
GENERAL FLOOR PLAN NOTES
A
B C D E F G
857 SF
CLASSROOM
002B
363 SF
BREAK
006B
404 SF
OFFICE
001D
1099 SF
OFFICE
S F
C O
R R
ID
O
R
1-
182 SF
CORRIDOR
001-3
203 SF
TOILET (M)
248 SF
TOILET (W)
806 SF
CLASSROOM
005A
805 SF
CLASSROOM
004A
812 SF
CLASSROOM
003B
426 SF
WAITING
006A
STAIR
NORTH
ELEV
NORTH
005B
005A
004B
001C
004A
001B
003A
2B
2A
D -0
D-009
AE400
AE400
ELEV
SOUTH
STAIR
SOUTH
806 SF
CLASSROOM
002A
800 SF
CLASSROOM
003A
806 SF
CLASSROOM
004B
840 SF
CLASSROOM
005B
C O
F F
E E
ELEC
001B
65 SF
STOR.
001C
D3
H3
D3
D3
D3
C3
C3
D -S
T A
IR
-S
'-7
/2
'-0
/2
'-0
'-6
/4
'-0
/4
'-6
'-0
/2
A3
C3
C3
OFFICE
001A
437 SF
WAITING
001E
C3
A3
C3
C3
001E
1A
001D
003B
TELECOM
008A
CORRIDOR
001-1
NEW ABA
COMPLIANT
DRINKING
FOUNTAIN
35'-6"3'-3"40'-2"
7'-0"
46'-8"
4'-1 1/2" 17'-6" 6'-5"
15'-0"
2' -4
9'
-1
/2
5' -0
/4
5'
-5
/4
'-7
'-8
/4
7'
-1
/4
'-5
/2
6'
-6
6' -6
'-6
'-6
6'
-6
6' -9
/2
'-3
7' -0
'-8
/2
6' -2
/2
'-8
/2
8' -7
/2
'-7
E Q
E Q
ALIGN
ALIGN
ALIGN
FEC
R1R1R1
R1 R1
R1 R1
3'-4 1/4" 35'-4 3/4"
3'-3" 35'-6"
21'-7 1/2" 6'-5" 3'-3 1/4" 35'-6"
D3
A4
A4
A3
A4A4
A4 A4 A4 A4
A4
A4
A3
A3
A4
A4
A3
A3 A4
A4
A3
A3
A4
A4
A4
A4 A3
A3
A4
A4
A3
A3 A4
A4 A4
A4 A4A4 A4
A4
A4
A4 A4
A3 A4
A4
A4
A4
ALCOVE
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
FV
20'-0"
FV
26'-0"
FV
133'-0"
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
6'
-0
3C
A3
CONFERENCE ROOM
008F
OFFICE
008C
FISCAL SERVICE
DIRECTOR
OFFICE
008C
OFFICE
020E
OFFICE
020D
OFFICE
020C
OFFICE
020B
OFFICE
020A
VESTIBULE
020-61
BREAK
020G
UNION OFFICE
011A
UNION OFFICE
011 CANTEEN STORAGE
009-61
ELECTRICAL
LOADING DOCK
CORRIDOR
CORR
MECHANICAL ROOM
CORRIDOR
SERVER ROOM
015B
IRM
STOR
015A
HAC
RESTROOM
RESTROOM
ELEVATOR ROOM
COMPUTER LAB
OFFICE
ELEV CONTROL
FEC
FEC
F E
C
FEC
FEC
FEC
FEC
A3
FEC
FEC
FEC
FEC
FEC
FEC
FEC
4B
3A
ROOM NAME
000A
150 SF
AREA IS NOT IN CONTRACT
EXISTING WALLS
NEW DOOR / DOOR TAG
ROOM TAG / ROOM NUMBER / AREA
PARTITION TAG
WINDOW TAG
0.
FLOOR PLAN LEGEND
DEMOUNTABLE PARTITION SYSTEM
REFERENCE SPECIFICATIONS - BASIS OF DESIGN: DIRTT
BUILDING 61 KEY PLAN - GROUND FLOOR
PHASE 2
RENOVATED
TRAINING AND
OFFICE SPACE
N
PHASE 2
RENOVATED
OFFICE SPACE
OUT OF SCOPE
PHASE 1
RESTROOMS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:1
P
M
B61, GROUND LEVEL - REFERENCE PLAN
JLJ 22 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AE100
N
1/8" = 1'-0"
BUILDING 61 - GROUND LEVEL - REFERENCE PLAN1
C D E F G
514 SF
CLASSROOM
816 SF
CLASSROOM
106A
798 SF
CLASSROOM
106B
802 SF
CLASSROOM
107A
797 SF
CLASSROOM
107B
879 SF
CLASSROOM
246 SF
CONFERENCE
CORRIDOR
VFW
VETERAN'S OF AMERICA
PARALYZED OFFICE
KANSAS COMMISSION
VETERAN'S AFFAIRS
QUALITY ASSURANCE
TLT
TLT
VESTIBULE
107B
107A
106B
105 106A
3'-3" 35'-2 1/4"3'-3"
18'-8" 8'-0" 6'-11"
3'-3" 35'-2 1/2"
'-5
6'
-6
6' -6
'-0
6' -6
6'
-6
'-8
/4
5'
-1
3/ 4"
'-5
/2
'-2
/2
5' -1
3/
4"
R1R1
R1R1
D6
D3
D3D3
34'-11 3/4"3'-4 1/4"
D3D3
D3
D6
D3
D3
D3
D6
D3
D3
A4 A4 A4
A4
A4 A3
A4
A4 A3
A3
A4 A3
A4 A4
A4 A3
A4 A3
A4
A3
A4 A3
A4 A4
A4A4
A L
C O
V E
0A
A L
C O
V E
B
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
0'
-0
FV
87'-0"
D3
AE200
F E
C
FEC
STAIR
NORTH
ELEV
NORTH
4B
3A
ROOM NAME
000A
150 SF
AREA IS NOT IN CONTRACT
EXISTING WALLS
NEW DOOR / DOOR TAG
ROOM TAG / ROOM NUMBER / AREA
PARTITION TAG
WINDOW TAG
0.
FLOOR PLAN LEGEND
DEMOUNTABLE PARTITION SYSTEM
REFERENCE SPECIFICATIONS - BASIS OF DESIGN: DIRTT
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF
ADJACENT WALL UNLESS NOTED OTHERWISE.
2. ALL WALLS ARE TYPE D3 PARTITIONS UNLESS NOTED OTHERWISE. REFER TO PARTITION TYPE
SHEET FOR WALL TYPES.
3. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.
4. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.
5. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW
TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.
6. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.
7. ANY CONSTRUCTION ACTIVITY THAT IMPACTS THE FIRE OR SMOKE RATING OF EXISTING
WALLS SHALL BE PROPERLY REPAIRED AND FIRESTOPPED AS REQUIRED TO MAINTAIN THE
EXISTING RATING.
GENERAL FLOOR PLAN NOTES
BUILDING 61 KEY PLAN - FIRST FLOOR
PHASE 1
RENOVATED
TRAINING AND
OFFICE SPACE
NOUT OF SCOPE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:2
P
M
B61, LEVEL 1 - REFERENCE PLAN
JLJ 23 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AE101
N
1/8" = 1'-0"
BLDG 61 - LEVEL 1 - REFERENCE PLAN1
A
B C D E F G
26'-0"20'-0"20'-6"20'-6"20'-0"26'-0"
133'-0"
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
6'
-0
WAITING
006A
OFFICE
001D
CLASSROOM
004A
CORRIDOR
001-3
BREAK
006B
CLASSROOM
003B
CLASSROOM
002B
OFFICE
TOILET (W)
TOILET (M)
C O
R R
ID
O
R
1-
C O
F F
E E
CLASSROOM
005A
CLASSROOM
002A
CLASSROOM
003A
CLASSROOM
004B
CLASSROOM
005B
E L
E C
B
E-5
STAIR
NORTH
ELEV
NORTH
ELEV
SOUTH
STAIR
SOUTH
OFFICE
001A
E-5
E-5
S T
O R
1C
E-5
WAITING
001E
CORRIDOR
001-1
F-2F-2
F-2F-2 F-2F-2 F-2F-2 F-2F-2 F-2F-2
F-2F-2F-2F-2F-2F-2F-2F-2F-2F-2
A-5 E-4 E-2E-2
E-4
E-5
F-1
F-1
F-1 F-1
E-4
F-3
F-3
F-3
F-3
F-3
F-1F-1F-1
F-7
F-7
F-8
F-8
E-5
F-8
F-8
F-8
F-8
F-8
F-8
F-9
F-6
F-9
F-6
F-6
F-9
F-6
F-9
F-3
F-3
F-3
F-3
F-3
F-9
F-6
F-2F-2
F-2
F-2F-2 F-2F-2
F-2 F-2 F-2
F-2 F-2F-2 F-2
F-8
F-8
F-7
F-1
F-7
F-2F-2 F-2F-2 F-2F-2 F-2F-2
F-3
F-3
F-3
F-3
F-3
F-3
F-3
F-3
F-3
F-3F-3
F-3
F-3
F-3
F-3F-3
F-3
F-3
F-3
F-3
F-3
F-3
F-3
F-3
F-3 F-3
F-3
F-3
F-3
F-3F-3
F-3
F-3
F-3
F-3 F-3
F-3
F-3
F-3
F-3
F-1F-1F-1F-2F-2 F-2F-2 F-2F-2 F-2F-2
F-6
F-9
F-8
F-8
F-8
F-9
F-6
F-2F-2 F-2F-2 F-2F-2 F-2F-2
F-7
F-8
F-7
F-2
F-2
F-2F-2
F-2
F-2 F-2
F-2
F-2F-2
F-2
F-2F-2F-2F-2
F-2F-2
F-2 F-2F-2
F-2
F-10
F-10F-10
F-10F-10
F-10F-10
F-10F-10
F-10F-10
F-10
F-10
F-10
F-10F-10 F-10F-10
F-10F-10F-10F-10F-4
F-4F-4
F-4
F-4 F-4
F-4F-4
F-10
F-10
F-11
F-13
F-13
F-14
F-14
F-12 F-12
F-15
F-15
F-15
F-15
F-16F-16
ALCOVE
E-6
OFFICE
OFFICE
008C
OFFICE
008C
OFFICE
020E
OFFICE
020D
OFFICE
020C
OFFICE
020B
OFFICE
020A
COMPUTER LAB
FISCAL SERVICE
DIRECTOR
CONFERENCE ROOM
008F
AFGE UNION OFFICE
011A
UNION OFFICE
BREAK
020G
VESTIBULE
020-61
MECHANICAL ROOM
CANTEEN STORAGE
009-61
ELECTRICAL
LOADING DOCK
CORRIDOR
CORR
CORRIDOR
CORRIDOR
IRM
SERVER ROOM
015B
RESTROOM
RESTROOM
ELEVATOR ROOM
HAC
STOR
015A
CORRIDOR
ELEV CONTROL
F-17
F-17
F-17
F-17
TOILET
ROOM
BREAK
ADMIN
SUPPORT
SPACE
56'-0"
'-6
1229 SF
TEMPORARY
TRAILER
T-1
TEMPORARY TRAILERS ARE NOT INCLUDED IN PROJECT SCOPE, SHOWN FOR PROGRAMMING PURPOSES ONLY.
ROOM NAME
000A
AREA IS NOT IN CONTRACT
ROOM TAG / ROOM NUMBER
FF&E FLOOR PLAN LEGEND
ALL FURNITURE IS SHOWN FOR PROGRAMMING PURPOSES ONLY.
FURNITURE PROCUREMENT IS NOT INCLUDED IN THIS CONTRACT.
FF&E FLOOR PLAN GENERAL NOTES
56'-0"
'-6
CONFERENCE1229 SF
TEMPORARY
TRAILER
T-2
TOILET
ROOM
BREAK
ADMIN
SUPPORT
SPACE
TEMPORARY TRAILERS ARE NOT INCLUDED IN PROJECT SCOPE, SHOWN FOR PROGRAMMING PURPOSES ONLY.
BUILDING 61 KEY PLAN - GROUND FLOOR
PHASE 2
RENOVATED
TRAINING AND
OFFICE SPACE
N
PHASE 2
RENOVATED
OFFICE SPACE
OUT OF SCOPE
PHASE 1
RESTROOMS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:3
P
M
B61, GROUND LEVEL - FF&E FLOOR PLAN
JLJ 24 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AE102
N
1/8" = 1'-0"
BUILDING 61 - GROUND LEVEL - FF&E1
1/8" = 1'-0"
TEMPORARY TRAILER3
1/8" = 1'-0"
TEMPORARY TRAILER2
FURNITURE, FIXTURES, EQUIPMENT SCHEDULE, ENLARGED PLAN
MARK COMMENTS
ACQUISITION
LE
S
S E
E P
R O
V
ID
E D
LE
S
S E
E
IN
S T
A
LL
E D
C O
N T
R A
C T
O R
P R
O V
ID
E
D
C O
N T
R A
C T
O R
IN
S
T A
LL
E
D
V A
P R
O V
ID
E
D
V A
IN
S
T A
LL
E
D
A-1 36" STAINLESS STEEL GRAB BAR ● ●
A-2 42" STAINLESS STEEL GRAB BAR ● ●
A-3 18" STAINLESS STEEL VERTICAL GRAB BAR ● ●
A-4 SURFACE MOUNTED BABY CHANGING STATION ● ●
A-5 WASTE RECEPTICAL ● ●
A-6 SURFACE MOUNTED SOAP DISPENSER ● ●
A-7 SURFACE MOUNTED PAPER TOWEL DISPENSER ● ●
A-8 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL ● ●
A-9 MIRROR ● ●
A-10 SURFACE MOUNTED SEAT COVER DISPENSER ● ●
A-11 SURFACE MOUNTED TOILET PAPER DISPENSER ● ●
E-2 MICROWAVE ● ●
E-4 COFFEE POT ● ●
E-5 TELEVISION ● ●
E-6 REFRIGERATOR ● ●
F-1 WORKSTATION WITH RETURN AND CHAIR ● ●
F-2 WORKSTATION AND CHAIR ● ●
F-3 CHAIR ● ●
F-4 RECEPTION CHAIR ● ●
F-5 CONFERENCE TABLE ● ●
F-6 LECTURN ● ●
F-7 SURFACE MOUNTED MARKER BOARD ● ●
F-8 BOOKSHELF ● ●
F-9 STOOL ● ●
F-10 TASK CHAIR ● ●
F-11 CONFERENCE TABLE ● ●
F-12 SOFA ● ●
F-13 BAR HEIGHT TABLE SQUARE ● ●
F-14 COUNTER HEIGHT TABLE ROUND ● ●
F-15 COUNTER HEIGHT TABLE SQUARE ● ●
F-16 BANQUET SEATING ● ●
F-17 DEMOUNTABLE PARTITIONS ● ●
C D E F G
CORRIDOR
VFW
VETERAN'S OF AMERICA
PARALYZED OFFICE
KANSAS COMMISSION
VETERAN'S AFFAIRS
QUALITY ASSURANCE
TLT
TLT
VESTIBULE
F-2 F-2 F-2 F-2 F-2F-2F-2F-2F-2F-2
F-2 F-2 F-2 F-2 F-2F-2 F-2 F-2 F-2 F-2
F-2F-2F-2F-2F-2F-2 F-2 F-2 F-2 F-2
F-2 F-2 F-2 F-2 F-2F-2F-2F-2F-2F-2
F-2 F-2 F-2 F-2 F-2F-2F-2F-2F-2F-2
F-3F-3 F-3
F-3F-3F-3
F-5
F-4F-4
F-2F-2
F-2F-2
F-2F-2F-2
F-7
F-7
F-7
F-7
F-7
F-7
F-6
F-9
F-9
F-6
F-9
F-6
F-9
F-6
F-9
F-6
F-6
F-9
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
0'
-0
FV
87'-0"
ELEV
NORTH
STAIR
NORTH
CLASSROOM
CLASSROOM
106A
CLASSROOM
106B
CLASSROOM
107A
CLASSROOM
107B
CLASSROOM
CONFERENCE
C O
R R
ID
O
R
A L
C O
V E
B A
L C
O V
E
0A
AE200
F-17
F-17
ROOM NAME
000A
AREA IS NOT IN CONTRACT
ROOM TAG / ROOM NUMBER
FF&E FLOOR PLAN LEGEND
ALL FURNITURE IS SHOWN FOR PROGRAMMING PURPOSES ONLY.
FURNITURE PROCUREMENT IS NOT INCLUDED IN THIS CONTRACT.
FF&E FLOOR PLAN GENERAL NOTES
BUILDING 61 KEY PLAN - FIRST FLOOR
PHASE 1
RENOVATED
TRAINING AND
OFFICE SPACE
NOUT OF SCOPE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:3
P
M
B61, LEVEL 1 - FF&E FLOOR PLAN
JLJ 25 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AE103
N
1/8" = 1'-0"
BUILDING 61 - LEVEL 1 - FF&E PLAN1
FURNITURE, FIXTURES, EQUIPMENT SCHEDULE, OVERALL
MARK COMMENTS
ACQUISITION
C E
R N
E R
P R
O V
ID
E
D
C E
R N
E R
IN
S
T A
LL
E
D
C O
N T
R A
C T
O R
P R
O V
ID
E
D
C O
N T
R A
C T
O R
IN
S
T A
LL
E
D
V A
P R
O V
ID
E
D
V A
IN
S
T A
LL
E
D
A-1 36" STAINLESS STEEL GRAB BAR ● ●
A-2 42" STAINLESS STEEL GRAB BAR ● ●
A-3 18" STAINLESS STEEL VERTICAL GRAB BAR ● ●
A-4 SURFACE MOUNTED BABY CHANGING STATION ● ●
A-5 WASTE RECEPTICAL ● ●
A-6 SURFACE MOUNTED SOAP DISPENSER ● ●
A-7 SURFACE MOUNTED PAPER TOWEL DISPENSER ● ●
A-8 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL ● ●
A-9 MIRROR ● ●
A-10 SURFACE MOUNTED SEAT COVER DISPENSER ● ●
A-11 SURFACE MOUNTED TOILET PAPER DISPENSER ● ●
E-2 MICROWAVE ● ●
E-4 COFFEE POT ● ●
E-5 TELEVISION ● ●
E-6 REFRIGERATOR ● ●
F-1 WORKSTATION WITH RETURN AND CHAIR ● ●
F-2 WORKSTATION AND CHAIR ● ●
F-3 CHAIR ● ●
F-4 RECEPTION CHAIR ● ●
F-5 CONFERENCE TABLE ● ●
F-6 LECTURN ● ●
F-7 SURFACE MOUNTED MARKER BOARD ● ●
F-8 BOOKSHELF ● ●
F-9 STOOL ● ●
F-10 TASK CHAIR ● ●
F-11 CONFERENCE TABLE ● ●
F-12 SOFA ● ●
F-13 BAR HEIGHT TABLE SQUARE ● ●
F-14 COUNTER HEIGHT TABLE ROUND ● ●
F-15 COUNTER HEIGHT TABLE SQUARE ● ●
F-16 BANQUET SEATING ● ●
F-17 DEMOUNTABLE PARTITIONS ● ●
1. ALL UPPER CABINETS TO HAVE 30° SLOPED TOP. (REF:
MILLWORK DETAILS)
2. TOILET PARTITIONS TO BE BRADLEY STAINLESS STEEL,
FLOOR MOUNTED, OVERHEAD BRACED, IN TEXTURED
STAINLESS (OR EQUAL).
3. ALL WOOD-LOOK PLANKS TO BE LAID IN THE SAME
DIRECTION AS THE LONGEST DIMENSION OF THE ROOM.
4. ALL CONSTRUCTION SHALL CONFORM TO THE AMERICANS
WITH DISABILITIES ACT, ACCESSIBILITY GUIDELINES
(ADAAG), LOCAL GOVERNING FIRE, SAFETY, AND BUILDING
CODES, REQUIREMENTS AND REGULATIONS, 2015 IBC, ANSI
A117.1-2003.
5. ALL DIMENSIONS ARE TO THE FACE OF CONCRETE OR
MASONRY, FACE OR CENTERLINE OF STUD WALLS, OR
CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE.
6. ASBESTOS OR ASBESTOS CONTAINING PRODUCTS ARE
NOT ALLOWED IN ANY ASPECT OF THIS CONSTRUCTION.
7. COORDINATE ALL DISCIPLINES AND ALL ASPECTS OF
WORK. CONFLICTS AND DISCREPENCIES SHALL BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT
IMMEDIATELY.
8. ALL CONCRETE SURFACES WHICH RECEIVE A SPECIAL
FINISH, FLOOR COVERING, COATINGS, HARDENERS, ETC.
SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE
SPECIFIC FINISH MANUFACTURER'S SPECIFICATIONS AND
INSTRUCTIONS. PRIOR TO APPLICATION OF A SPECIAL
FINISH, A WRITTEN ACCEPTANCE OF THE SURFACE
SHALL BE SUBMITTED TO THE ARCHITECT BY THE GENERAL
CONTRACTOR.
9. REFER TO STRUCTURAL FOR RECESSED SLAB LOCATIONS,
SLOPED SLABS AND DIMENSIONS.
10. REMOVE ALL FLOOR FINISHES AND ADHESIVES AND STRIP
FLOOR DOWN TO EXISTING CONCRETE. PREP FLOOR FOR
INSTALLATION OF NEW FLOOR FINISHES AS SHOWN.
11. ALL WINDOWS TO RECEIVE MANUAL ROLLER SHADES WT1
(REFER SPECIFICATIONS)
GENERAL FINISH NOTES
SEALED CONCRETE (CS-1)
LUXURY VINYL TILE (LVT-1)
PORCELAIN TILE (PT-1)
AREA IS NOT IN CONTRACT
FINISH PLAN LEGEND
CARPET TILE (CPT-1)
A
B C D E F G
26'-0"20'-0"20'-6"20'-6"20'-0"26'-0"
133'-0"
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
6'
-0
CLASSROOM
002B
BREAK
006B
OFFICE
001D
OFFICE
C O
R R
ID
O
R
1-
CORRIDOR
001-3
TOILET (M)
TOILET (W)
CLASSROOM
005A
CLASSROOM
004A
CLASSROOM
003B
WAITING
006A
STAIR
NORTH
ELEC
001B
STOR.
001C
CLASSROOM
004B
CLASSROOM
005B
CLASSROOM
003A
CLASSROOM
002A
OFFICE
001A
WAITING
001E
CORRIDOR
001-1
COFFEE
ALCOVE
CG1 CG1
CG1 CG1
CG1
CG1
CG1 CG1
CG1 CG1
CG1 CG1
CG1
CG1
CG1 CG1
CG1 CG1
CG1 CG1
CG1 CG1
CG1 CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1CG1
CG1 CG1
CG1CG1 CG1 CG1 CG1
CG1
CG1
CG1
CG1
CG1 CG1 CG1 CG1 CG1 CG1
CG1
CG1CG1
CG1
CG1
CG1
CG1
CG1
CG1CG1
CG1CG1
CG1 CG1
CG1 CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1CG1 CG1CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1 CG1
CG1 CG1
CG1
CG1 CG1
CG1 CG1 CG1
CG1
CG1
CG1
OFFICE
OFFICE
008C
OFFICE
008C
OFFICE
020E
OFFICE
020D
OFFICE
020C
OFFICE
020B
OFFICE
020A
COMPUTER LAB
FISCAL SERVICE
DIRECTOR
CONFERENCE ROOM
008F
AFGE UNION OFFICE
011A
UNION OFFICE
BREAK
020G
VESTIBULE
020-61
MECHANICAL ROOM
CANTEEN STORAGE
009-61
ELECTRICAL
LOADING DOCK
CORRIDOR
CORR
CORRIDOR
CORRIDOR
IRM
SERVER ROOM
015B
RESTROOM
RESTROOM
ELEVATOR ROOM
HAC
STOR
015A
CORRIDOR
ELEV CONTROL
ELEV
NORTH
STAIR
SOUTH
TR1
TR1
TR1
TR2
TR2
BUILDING 61 KEY PLAN - GROUND FLOOR
PHASE 2
RENOVATED
TRAINING AND
OFFICE SPACE
N
PHASE 2
RENOVATED
OFFICE SPACE
OUT OF SCOPE
PHASE 1
RESTROOMS
Training Room
1/
2"
8 1/2"
S2
ROOM NUMBER IN ADA COMPLIANT TACTILE NUMERALS AND BRAILLE
BLACK ADA_FUTURA FONT OR SIMILAR BY MANUFACTURER
LAMINATE FINISH FACE PLATE
SILVER WINGS LAMINATE OR SIMILAR BY MANUFACTURER
METAL ACCENT STRIP
BLACK FINISH OR SIMILAR BY MANUFACTURER
ROOM NAME PLATE INSERT
TRANSPARENT INSERT BACKGROUND WITH EMPLOYEE NAME
IN BLACK ADA_FUTURA FONT OR SIMILAR BY MANUFACTURER
TAPE AND SILICONE INSTALLATION PER MANUFACTURER
48" AFF MINIMUM TO BOTTOM EDGE OF COPY
S1
STORAGE4
1/ 4"
8 1/2"
ROOM NAME AND NUMBER IN ADA COMPLIANT TACTILE NUMERALS AND
BRAILLE BLACK ADA_FUTURA FONT OR SIMILAR BY MANUFACTURER
LAMINATE FINISH FACE PLATE
SILVER WINGS LAMINATE OR SIMILAR BY MANUFACTURER
TAPE AND SILICONE INSTALLATION PER MANUFACTURER
INSTALLATION: CENTER OF SIGN TO BE 9" FROM DOOR FRAME, UNLESS
NOTED OTHERWISE. BASE OF TACTILE COPY TO BE A MINIMUM OF 48"
ABOVE FINISHED FLOOR, MAXIMUM OF 60" ABOVE FINISHED FLOOR.
BASIS OF DESIGN: TAKEFORM FUSION | 04, TYPE H F04B-D1
INSTALLATION: CENTER OF SIGN TO BE 9" FROM DOOR FRAME, UNLESS
OTHERWISE NOTED. BASE OF TACTILE COPY TO BE A MINIMUM OF 48"
ABOVE FINISHED FLOOR, MAXIMUM OF 60" ABOVE FINISHED FLOOR.
BASIS OF DESIGN: TAKEFORM FUSION | 04, TYPE G.2 F04B1-BH
SIGNAGE TYPES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:5
:4
P
M
B61, GROUND LEVEL - FINISH FLOOR PLAN
JLJ 26 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
AE104
ROOM FINISH SCHEDULE
ROOM
ROOM NAME
FLOOR FINISHES WALL FINISHES
CEILING
MATERIAL BASE NORTH EAST SOUTH WEST
001 COFFEE LVT1 RB1 P1 -- P1 P1/CT1/CT2 P2
001-1 CORRIDOR CPT1 RB1 P1 P1 P1 P1 ACT1/P2
001-2 CORRIDOR CPT1 RB1 P1 P1 P1 P1 ACT1/P2
001-3 CORRIDOR CPT1 RB1 P1 P1 P1 P1 ACT1
001A OFFICE CPT1 RB1 P3 P3 P3 P3 ACT1
001B ELEC CS1 RB1 P1 P1 P1 P1 NO CEILING
001C STOR. CS1 RB1 P1 P1 P1 P1 NO CEILING
001D OFFICE CPT1 RB1 P3 P3 P3 P3 ACT1
001E WAITING CPT1 RB1 P3 P3 P3 P3 ACT1
002A CLASSROOM CPT1 RB1 P3 P3 P3/DP1 P3 ACT1/P2
002B CLASSROOM CPT1 RB1 P3/DP1 P3 P3 P3 ACT1/P2
003A CLASSROOM CPT1 RB1 P3 P3 P3/DP2 P3 ACT1/P2
003B CLASSROOM CPT1 RB1 P3/DP2 P3 P3 P3 ACT1/P2
004A CLASSROOM CPT1 RB1 P3 P3 P3/DP1 P3 ACT1/P2
004B CLASSROOM CPT1 RB1 P3/DP1 P3 P3 P3 ACT1/P2
005A CLASSROOM CPT1 RB1 P3 P3 P3/DP1 P3 ACT1/P2
005B CLASSROOM CPT1 RB1 P3/DP1 P3 P3 P3 ACT1/P2
006A WAITING LVT1 RB1 P3 P3 P3/CT1/CT2 P3 ACT1
006B BREAK LVT1 RB1 P3 P3/CT1/CT2 P3/CT1/CT2 P3 ACT1/P2
009 OFFICE CPT1 RB1 P3 P3 P3 P3 ACT1
012 ALCOVE CPT1 RB1 P1 P1 P1 -- P2
100A ALCOVE CPT1 RB1 P1 P1 P1 -- P2
100B ALCOVE CPT1 RB1 P1 P1 P1 -- P2
103 CORRIDOR CPT1 RB1 P1 P1 P1 P1 ACT1/P2
104 CONFERENCE LVT1 RB1 P3…