5 of 8 - 589A7-21-702 Plumbing Dwgs.pdf
PDF 2 MB Posted
- Attached to
- Y1DA--589A7-21-702 EHRM Training and Admin Support Space (TASS) Construction - Wichita, KS
- Solicitation number
- 36C77622B0033
About this file
This solicitation is seeking a general contractor to complete renovations at the Robert J. Dole VA Medical Center in Wichita, Kansas. The project involves renovating approximately 12,000 square feet on the ground level of Building 61 to create EHRM Training and Admin Support Space. The solicitation requires furnishing all labor, materials, equipment, qualified supervision and other items designated in the specifications and drawings to complete the project. The Department of Veterans Affairs Technology Acquisition Center Austin issued the solicitation.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MA
MV
CO
VEAI
FOV
FOR
FOS
LPG
NPW
NO
O
N
G
MPG
CA
CD
ACD
VAV
AW
ST
OST
GW
SS
SCW
140°ORAL EVACUATION
LABORATORY VACUUM
LABORATORY AIR
INDUSTRIAL AIR
LA
LV
OA
IA
FILTERED COLD WATERFCW
FUEL OIL DISCHARGEFOD
SQUARE FLOOR DRAIN (FD)
ROOF DRAIN (RD), SIZE & TYPESQUARE FLOOR SINK (FS)
CONDENSATE DRAIN
NATURAL GAS
NITROUS OXIDE
LIQUIFIED PETROLEUM GAS
COMPRESSED AIR
NITROGEN
MEDICAL AIR
OXYGEN
DOMESTIC HOT WATER RECIRC.
STORM DRAIN
ACID WASTE
DOMESTIC COLD WATER
DOMESTIC HOT WATER
140° DOMESTIC HOT WATER (140°)
SANITARY SEWER
GREASE WASTE
SOFTENED COLD WATER (SCW)
ACID VENT VENT
WALL CLEANOUT (WCO)
FLOOR CLEANOUT (FCO)
OVERFLOW STORM DRAIN
NON POTABLE WATER (NPW)
FUEL OIL SUPPLY
FUEL OIL RETURN
FUEL OIL VENT
AUXILIARY CONDENSATE DRAIN
CARBON DIOXIDE
MEDICAL VACUUM
MEDICAL VACUUM EXHAUSTMEDICAL AIR INTAKE
MEDIUM PRESSURE NATURAL GAS
END OF LINE CLEANOUT
PLUMBING EQUIPMENT DESIGNATIONXX-1
A. ALL PIPING SHALL BE COORDINATED WITH CIVIL UTILITY PIPING, FIRE PROTECTION,
DUCTWORK, MECHANICAL PIPING, LIGHTING, STRUCTURAL AND ARCHITECTURAL SYSTEMS.
B. PIPE CLEANOUTS SHALL BE LINE SIZE (6" MAX.). LOCATE 100' APART MAXIMUM FOR SIZES UP
THROUGH 6".
C. PLUMBING VENTS THROUGH ROOF (VTR) SHALL BE 3" MINIMUM. SMALLER VTR'S INDICATED
SHALL INCREASE TO 3" PIPE, 12" BELOW ROOF.
D. ACCESS PANELS SHALL BE PROVIDED FOR ALL WATER HAMMER ARRESTORS LOCATED IN
WALLS TO ACCESS EQUIPMENT. PANEL SHALL BE AS LARGE AS PRACTICAL FOR THE
FUNCTION THEY ARE INTENDED.
E. DO NOT SCALE DRAWINGS, SEE ARCHITECTURAL FLOOR PLAN FOR DIMENSIONS.
F. ALL PLUMBING WORK SHALL COMPLY WITH THE 2009 INTERNATIONAL PLUMBING CODE.
G. PIPE ROUTING IS SCHEMATIC AS SHOWN AND IS NOT INTENDED TO INDICATE EXACT
ROUTING. CONTRACTOR SHALL PROVIDE ANY ADDITIONAL OFFSET AND FITTINGS REQUIRED
FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES.
H. CONCEAL PIPING ABOVE CEILING AND WITHIN WALLS OR CHASES, EXCEPT IN MECHANICAL
SPACES OR WHEN OTHERWISE NOTED.
DHWR
DHW
DCW
ABBREVIATIONS
THIS LEGEND DEFINING TYPICAL ABBREVIATIONS AND SYMBOLS IS INTENDED TO BE AN OVERALL LEGEND FOR ALL PROJECTS. PLEASE UNDERSTAND THAT NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR EVERY PROJECT. MANY OF THE SYMBOLS WILL BE UTILIZED IN DETAILS AND DIAGRAMS VIA PLAN SHEETS.
PLUMBING PIPING TYPES
A/E ARCHITECT / ENGINEER
B
BFP REDUCED PRESSURE BACKFLOW
PREVENTER
BHP BRAKE HORSEPOWER
BT BATHTUB
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
DA
F FAHRENHEIT
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
E
ET EXPANSION TANK
FD FLOOR DRAIN
FM FLOW METER
FOP FUEL OIL PUMP
FOV FUEL OIL VENT
G
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GT GREASE TRAP
K
J
J INTENTIONALLY LEFT BLANK
ID INSIDE DIAMETER
H
H&CW HOT & COLD WATER
HB HOSE BIBB
HD HUB DRAIN
HP HORSEPOWER
HWP HOT WATER PUMP
I
L
L/s LITERS PER SECOND (OR LITERS/SECOND)
LA LABORATORY AIR
LBS/HR POUNDS PER HOUR
NTS NOT TO SCALE
N
NC NORMALLY CLOSED
NG NATURAL GAS
M
M METER, SI UNIT
MA MEDICAL AIR
MAV MANUAL AIR VENT
MBH 1000 BTUH
P
PP PLUMBING PUMP
PA PASCAL
PD PRESSURE DROP
PG PRESSURE GAGE
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH – ABSOLUTE
PSIG POUNDS PER SQUARE INCH – GAGE
PTRV PRESSURE TEMPERATURE RELIEF VALVE
O
O OXYGEN
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
Q
Q INTENTIONALLY LEFT BLANK
TCV TEMPERATURE CONTROL VALVE
TD TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TSTAT THERMOSTAT
TWR TEMPERED WATER RETURN
SAN SANITARY SEWER
SCFM STANDARD CUBIC FEET PER MINUTE
SQ FT SQUARE FOOT (FEET)
SS STAINLESS STEEL
ST STORAGE TANK
R
RD ROOF DRAIN
RO REVERSE OSMOSIS
T
X INTENTIONALLY LEFT BLANK
W
W WASTE
WC WATER CLOSET
WG WATER GAGE
WPD WATER SIDE PRESSURE DROP
V VENT
VP VACUUM PUMP
VSD VARIABLE SPEED DRIVE
X
V
DEMOLITION GENERAL NOTES:
PL-100
DETAIL NUMBER
SHEET NUMBER
SHEET NUMBER
SECTION NUMBER
1 OWNER FURNISHED, CONTRACTOR
INSTALLED EQUIPMENT DESIGNATION
EXISTING TO BE DEMOLISHED
EXISTING TO REMAIN
NEW PIPE
CONNECT NEW TO EXISTING
LIMIT OF DEMOLITION
GENERAL PIPING SYMBOLS
GENERAL ANNOTATIONS
AV
STRAINER
FLOAT & THERMOSTATIC
STEAM TRAP
INVERTED BUCKET
STEAM TRAP
FLANGE CONNECTION PIPE DROP
PIPE RISER
TEE DOWN
TEE UP UNION
PRESSURE REDUCING
VALVE
BALL VALVE
ANGLE GLOBE VALVE SAFETY RELIEF VALVE
GLOBE VALVE
MANUAL OR
AUTOMATIC AIR VENT
PRESSURE AND
TEMPERATURE TEST PLUG
FLOW METER
PLUMBING PIPING SYMBOLS
CAP
REDUCER (ECCENTRIC)
Name
XX-XX
ANCHOR
TEE
DIRECTION OF FLOW
S
DIRECTION OF PIPE
PITCH (DOWN)
FM
MV
PLUMBING VALVE SYMBOLS
ROOM TAG
PUMP
REDUCER (CONCENTRIC)
BUTTERFLY VALVE
CHECK VALVE
THERMOMETER
PRESSURE GAUGE
YCO YARD CLEANOUT
Y
Z INTENTIONALLY LEFT BLANK
Z
AD AREA DRAIN
AFF ABOVE FINISHED FLOOR
AG AIR GAP
AFG ABOVE FINISHED GRADE
AP ACCESS PANEL
AS AUTOMATIC SPRINKLER
ASD ADJUSTABLE SPEED DRIVES
ASD AUTOMATIC SPRINKLER DRAIN
ASME AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AIR CONDITIONING
ENGINEERS
ASPE AMERICAN SOCIETY OF PLUMBING
ENGINEERS
ASR AUTOMATIC SPRINKLER RISER
AV ACID VENT
AW ACID WASTE
BSP BLACK STEEL PIPE
C
C CENTIGRADE (CELSIUS)
CFM CUBIC FEET PER MINUTE
CV CONTROL VALVE
CO CLEANOUT
CA COMPRESSED AIR
CGA COMPRESSED GAS ASSOCIATION
CI CAST IRON
CS CLINICAL SINK
DCW DOMESTIC COLD WATER
DFU DRAINAGE FIXTURE UNITS
DHW DOMESTIC HOT WATER
DI DEIONIZED WATER
DW DISHWASHER
DHWR DOMESTIC HOT WATER RETURN
DHWS DOMESTIC HOT WATER SUPPLY
DN DOWN
DS DOWNSPOUT
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWR DRINKING WATER RETURN
DWS DRINKING WATER SUPPLY
DWV DRAIN WASTE VENT
EX. EXISTING
EWS/SH EYE WASH/ DRENCH SHOWER
EWS EYE WASH STATION
EWH ELECTRIC WATER HEATER
ETR EXISTING TO REMAIN
ESH EMERGENCY SHOWER
ESC ESCUTCHEON
EPACT ENERGY POLICY ACT
EMCS ENERGY MONOSERRAT AND
CENTRAL SYSTEM
EPA ENVIRONMENTAL PROTECTION AGENCY
EL ELEVATION
F
FDC FIRE DEPARTMENT (HOSE) CONNECTION
FFA FROM FLOOR ABOVE
FFB FROM FLOOR BELOW
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FS FLOOR SINK
FS FLOW SWITCH
FU FIXTURE UNITS
GAL GALLONS
GCO GRADE CLEANOUTS
GPS GAS REGULATOR STATION
GVTR GAS VENT THROUGH ROOF
GWH GAS FIRED UNIT HEATER
HX HEAT EXCHANGER
HS HAND SINK
HST HOT WATER STORAGE TANK (DOMESTIC)
HWB HOT WATER BOILER
HWCP HOT WATER CIRCULATING PUMP
HYD HYDRANT
IE INVERT ELEVATION
ICW INDUSTRIAL COLD WATER
IHW INDUSTRIAL HOT WATER
INV INVERT
IPC INTERNATIONAL PLUMBING CODE
IRW IRRIGATION WATER
IW INDIRECT WASTE
IWH INSTANTANEOUS WATER HEATER
IWR INDUSTRIAL WATER RETURN
IWS INDUSTRIAL WATER SUPPLY
kW KILOWATT kWh KILOWATT HOUR
LAV LAVATORY
LCW LABORATORY COLD WATER
LHW LABORATORY HOT WATER
LV LABORATORY VACUUM
LNG LIQUID NATURAL GAS
LOX LIQUID OXYGEN
LW LOW WATER
MED MEDICAL
MER MECHANICAL EQUIPMENT ROOM
MH MANHOLE
MOU MEMORANDUM OF UNDERSTANDING
MSB MOP SERVICE BASIN
MV MEDICAL VACUUM
N2 NITROGEN
N2O NITROUS OXIDE
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM. NOMINAL
NPW NON POTABLE WATER
OC ON CENTER
OR OPERATING ROOM
OVFL OVERFLOW
PDI PLUMBING AND DRAINAGE INSTITUTE
PO POTABLE WATER
RDL ROOF DRAIN LEADER
RL ROOF LEADER
RP RECIRCULATION PUMP
RWL RAIN WATER LEADER
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOCIATION
SCW SOFTENED COLD WATER
SDMH STORM DRAIN MANHOLE
SMH SANITARY MANHOLE
SP SUMP PUMP
SPR SPRINKLER LINE
SW STORM WATER
TD TRENCH DRAIN
TEMP TEMPERATURE
TFA TO FLOOR ABOVE
TFB TO FLOOR BELOW
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
U
U INTENTIONALLY LEFT BLANK
VS VENT STACK
VTR VENT THROUGH ROOF
VAC VACUUM
VB VACUUM BREAKER
VCO VACUUM CLEANER OUTLET
WCO WALL CLEANOUT
WH WALL HYDRANT
WH WATER HEATER
WHA WATER HAMMER ARRESTER
WL WATER LINE
WM WATER METER
WS WASTE STACK
WSFU WATER SUPPLY FIXTURE UNITS
YH YARD HYDRANT
BACKFLOW PREVENTER
NONFREEZE WALL
HYDRANT
PLUMBING CLEANOUT AND DRAIN SYMBOLS
MODULATING CONTROL
VALVE
THERMOSTATIC MIXING
VALVE
M MOTOR OPERATED VALVE
I. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS.
J. PROVIDE TRAP PROTECTION FOR ALL FLOOR DRAINS.
K. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES, DEVICES, APPLIANCES AND APPARATUS.
L. COORDINATE PIPING WITH ELECTRICAL EQUIPMENT PRIOR TO INSTALLATION. ROUTE PIPING
TO AVOID ELECTRICAL EQUIPMENT AND CLEARANCE AREAS.
M. ANY DEVIATIONS IN ELECTRICAL REQUIREMENTS FROM THE BASIS OF DESIGN FOR THE
PLUMBING EQUIPMENT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO
ENSURE COORDINATION WITH THE ELECTRICAL CONTRACTOR FOR PROPER SIZE
ELECTRICAL MATERIAL AND EQUIPMENT AT NO ADDITIONAL COST.
N. PROVIDE SHOCK ARRESTORS PER STANDARD PDI-WH-201.
ROUND FLOOR DRAIN (FD)
GENERAL NOTES:
A. VERIFY EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY GENERAL CONTRACTOR
REGARDING CONFLICTS BEFORE PROCEEDING WITH WORK.
B. VERIFY SIZE AND LOCATION OF EXISTING UTILITIES PRIOR TO START OF DEMOLITION.
RELOCATE, REMOVE AND ADJUST MECHANICAL AND ELECTRICAL ITEMS AS NECESSARY TO
COORDINATE WITH NEW WORK.
C. AFTER DEMOLITION IS COMPLETE, PATCH AND REPAIR FINISHES TO MATCH EXISTING
CONDITIONS.
D. COORDINATE DEMOLITION WITH GENERAL CONTRACTOR. NOTIFY GENERAL CONTRACTOR
AND OWNER IF A SHUDTOWN OF UTILITIES IS REQUIRED.
E. PROTECT EXISTING UTILITIES TO REMAIN FROM DAMAGE DURING DEMOLITION.
F. TEMPORARILY MOVE OR TAKE EQUIPMENT OUT OF SERVICE AS NECESSARY TO COMPLETE
WORK.
G. SAWCUT CONCRETE FLOOR AS REQUIRED FOR DEMOLITION WORK INDICATED. COORDINATE
WITH NEW PLUMBING BEFORE CUTTING ANY FLOOR. CONTRACTOR TO X-RAY FLOORS FOR
ALL STRUCTURAL FLOORS.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2021
EXP. 12/31/2021
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
/2
/2
:1
:1
P
M
PLUMBING LEGEND AND ABBREVIATIONS
RDC 40 88JRM
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
01/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
P-000
No. REVISION DESCRIPTION DATE
6" SS
2" ST
3" SS
1 1/2" DHW3" DCW
10" ST
1 1/2" DHW
2 1/2" DCW
10" ST
4" SS
4" SS
2 1/2" DCW
1 1/2" DHW
2" DCW
2" DCW
3/4" DCW
6" ST
10" ST 3" ST
4" SS 4" SS
3" DHW 3" DCW
4" SS
10" ST
4" SS
3" SS
4" SS
2" DCW
A
B C D E F G
OFFICE
005B
OFFICE
OFFICE
OFFICE
005A
STORAGE
OFFICE
008E
OFFICE
008D
REGIONAL
OFFICE
DIRECTOR
DIRECTOR
OFFICE
008B
CONFERENCE
ROOM
OFFICE 006
[FUTURE TELECOM]
OFFICE
008D
OFFICE
005C
STORAGE
CANTEEN
STORAGE
ELECTRICAL
LOADING DOCK
MECHANICAL
015A
015B
P-401
P-401
REMOVE EXISTING
PLUMBING FIXTURE &
PIPING BACK TO MAINS
NOT IN
SCOPE
6" ST DOWN
FROM ROOF
4" SS
4" S
S
BUILDING 61 KEY PLAN - GROUND FLOOR
PHASE 2
RENOVATED
TRAINING AND
OFFICE SPACE
N
PHASE 2
RENOVATED
OFFICE SPACE
OUT OF SCOPE
PHASE 1
RESTROOMS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2021
EXP. 12/31/2021
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
/2
/2
:1
:3
P
M
B61, GROUND LEVEL - PLUMBING
DEMOLITION OVERALL PLAN
RDC 41 88JRM
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
01/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
PD101
N
1/8" = 1'-0"
B61, GROUND LEVEL - PLUMBING OVERALL DEMOLITION PLAN1
DEMOLITION KEYNOTES
D1 CONTRACTOR SHALL REMOVE EXISTING FIXTURE IN IT'S ENTIRETY INCLUDING SUPPORTS AND ACCESSORIES. REMOVE COLD WATER, HOT
WATER, AND VENT PIPING BACK TO ASSOCIATED MAIN AND CAP. CUT AND CAP SANITARY PIPING BELOW SLAB. FILL AND PATCH FLOORING
TO MATCH.
A
B C D E F G
CLASSROOM
002B
CLASSROOM
002A
CORRIDOR
001-1
OFFICE
001A
CLASSROOM
003A
CLASSROOM
003B
CLASSROOM
004A
CLASSROOM
004B
CLASSROOM
005A
OFFICE
001D
WAITING
001E
BREAK
006B
WAITING
006A
CORRIDOR
001-2
OFFICE
TELECOM
008A
ELEV
NORTH
STAIR
SOUTH
ELEV
SOUTH
CLASSROOM
005B
NOT IN SCOPE
P-401
(TYP)
P-524
4" S
S 4"
S S
4" SS 4" SS
3" S
S
3" S
S
4" S
S
EXIST. 4" VENT UP
2" V
6" ST
10" ST10" ST
3" S
T
3" S
S
S T
4" SS
4" SS
P-528
2" V
2" V
2" S
S
2" V
4" V
4" V
3" SS
2" SS
BUILDING 61 KEY PLAN - GROUND FLOOR
PHASE 2
RENOVATED
TRAINING AND
OFFICE SPACE
N
PHASE 2
RENOVATED
OFFICE SPACE
OUT OF SCOPE
PHASE 1
RESTROOMS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2021
EXP. 12/31/2021
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
/2
/2
:1
:3
P
M
B61, GROUND LEVEL - PLUMBING WASTE
PLAN
RDC 42 88JRM
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
01/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
PL101
N
1/8" = 1'-0"
GROUND LEVEL - PLUMBING WASTE/VENT PLAN1
A
B C D E F G
P-401
TOILET (M)
TOILET (W)
TELECOM
008A
CORRIDOR
001-3
ALCOVE
OFFICE
ELEV
NORTH
CLASSROOM
002B
CLASSROOM
002A
OFFICE
001A
CLASSROOM
003A
STAIR
NORTH
CORRIDOR
001-1
CORRIDOR
001-2
WAITING
001E
CORRIDOR
001-2
WAITING
006A
OFFICE
BREAK
006B
STAIR
SOUTH
ELEV
SOUTH
CLASSROOM
005B
CLASSROOM
005A
CLASSROOM
004B
CLASSROOM
004A
CLASSROOM
003B
1 1/2" DHW
2 1/2" DCW
STOR.
001C
ELEC
001B
1 1/2" DHW
3" DCW
3/4" DHWR
3" DCW
1 1/2" DHW
1/
2" D
C W
1" D
H W
R
1/ 2"
D H
W
1" DHWR
P-524
3/4" DHW
2" DCW
1" D
H W
R
1" DCW
3/4" DHW
1 1/4" DCW
3" DHW 3" DCW
3" D
C W
1/
2" D
H W
1/2" DCW
CONTINUES TO
SERVE BATHROOMS
ISO
VALVES
ISO
VALVES
DHWCP-1
BALANCE
VALVE, .25 GPM
BALANCE
VALVE, .25 GPM
P-528
1" DCW
1/2" DHW
3/4" DHWR
ISO
VALVES
1 1/2" DHW
2 1/2" DCW
2" DCW 3/4" DCW
2" D
C W
3/4" DHWR
BUILDING 61 KEY PLAN - GROUND FLOOR
PHASE 2
RENOVATED
TRAINING AND
OFFICE SPACE
N
PHASE 2
RENOVATED
OFFICE SPACE
OUT OF SCOPE
PHASE 1
RESTROOMS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2021
EXP. 12/31/2021
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
/2
/2
:1
:3
P
M
B61, GROUND LEVEL - PLUMBING SUPPLY
PLAN
RDC 43 88JRM
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
01/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
PP101
N
1/8" = 1'-0"
GROUND LEVEL - PLUMBING SUPPLY PLAN1
No. REVISION DESCRIPTION DATE
PLUMBING KEYNOTES
6 1/2" DHW/DCW DOWN TO FIXTURE.
17 CONNECT NEW 3/4" DHWR TO EXISTING DCW SUPPLY PIPE.
27 1/2" DCW DOWN FOR NEW COFFEEPOT CONNECTION, STUB OUT JUST ABOVE COUNTERTOP. PROVIDE SHUT OFF VALVES AND VACUUM
BREAKERS.
28 1/2" DCW DOWN TO FIXTURE.
4" SS
4" SS
3" SS
3" SS
2" V
2" V
2" V
4" S
S
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
3" S
S
3" S
S
3" S
S
3" S
S
2" V
2" V
3" S
S
2" SS
2" SS
3" SS
4" SS
2" SS
3" SS
3" V
3" V
2" V
2" V
3" S
S 2"
S S
2" SS
4" SS
4" SS
P-420
P-420
P-420
P-420
P-420
P-608
P-528
P-502
P-107
P-103
P-201
P-202 P-107
P-107
P-107
P-107
P-103
FD-C
(BEHIND)
2" SS
FLOOR
DRAIN
FD-C
(BEHIND)
4" SS
4" SS
4" SS
2" V
FD-C
1/ 2"
D H
W
1/2" DHWR
3/4" DHW
3/4" DHWR
2" DCW
1/ 2"
D H
W
1/ 2"
D C
W
1/ 2"
D C
W
1/ 2"
D H
W
1/ 2"
D C
W
1/ 2"
D H
W
3/ 4"
D H
W
3/4" DHW
3/4" DCW
1/2" DHWR
1/2" DHW
P-502
P-107
P-107
P-107
P-528
P-107
P-103
P-202
P-201 P-107
P-103
P-420 P-420
P-420
P-420
P-420
P-608
2" DCW
2" D
C W
2" D
C W
2" DCW
2" DCW
2" DCW
1" DHW
1" DHW
2 1/2" DCW
1 1/2" DHW
3/4" DHWR
WHA-C
1" DHW
1" DCW
2 1/2" DCW
3/4" DHW
2" DCW
3/4" DHWR
1/2" DHWR
2" DCW
1" DHW
2" DCW
2" DCW
EXISTING 1" DHW/DCW UP
TO FIRST FLOOR
WHA-C
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2021
EXP. 12/31/2021
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
/2
/2
:1
:2
P
M
PLUMBING ISOMETRICS
RDC 44 88JRM
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
01/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
P-301
BATHROOM GROUP WASTE/VENT ISOMETRIC VIEW1BATHROOM GROUP SUPPLY ISOMETRIC VIEW2
D E
P-103
P-107
P-201
P-202
P-107
P-107
P-107
P-107
P-103
P-502
P-528
TOILET (M)
ELEC
001B
STOR.
001C
COFFEE
TOILET (W)
P-608 P-420
P-420
P-420
P-420
P-420
WHA-C
1/ 2"
D H
W1" DHW2" DCW
1" DHW
2" DCW
WHA-C
2" D
C W
3/ 4"
D H
W 3/
4" D
H W
R
2" D
C W
2" DCW
1" DHW
1/2" DCW
1/2" DHWR
1" DHW
1" DCW
1/ 2"
D H
W R
D E
P-103
P-107
P-107
P-107
P-107
P-107
P-103
P-502
TOILET (M)
ELEC
001B
STOR.
001C
COFFEE
TOILET (W)
FD-C
FD-C
FD-C
FD-C
3" SS
2" S
S 4"
S S
3" S
S
4" S
S
2" SS
4" S
S 4"
S S
2" SS
2" SS
D E
P-103
P-107
P-201
P-202
P-107
P-107
P-107
P-107
P-103
P-502
P-528
TOILET (M)
ELEC
001B
STOR.
001C
COFFEE
TOILET (W)
P-608
FD-C
FD-C
FD-C
P-420
P-420
P-420
P-420
P-420
4" S
S 4"
S S
2" V
2" V
2" V
2" V
2" V
2" V
4" SS
WHA-C
3" S
S 3"
S S
3" S
S
3" SS
2" V
4" S
S
4" SS
D E
1 1/4" DCW
1 1/2" DHW
1" DCW & DHW UP
TO REMAIN
SHUT OFF
VALVES
2 1/2" DCW UP
TO REMAIN
1/2" DCW &
DHW DOWN
2" DCW
1/2" DHW
2 1/2" DCW
1" DCW
1 1/4" DCW
1/2" DHW
3/4" DCW
3/4" DHW
3/4" DCW
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DCW
1/2" DHW
1/2" DCW
D1
D1
D1
D1
D1
D1D1
D1D1
D E
2" V UP TO
REMAIN
4" SS UP TO
REMAIN
2" SS
CLEANOUT
1 1/2" V
1 1/2" V2" SS
1 1/2" V 2" SS
4" SS
4" SS
1 1/2" V
2" SS
3" SS
D1
D1
D1D1
D1D1
D1
D1
D1
D2 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2021
EXP. 12/31/2021
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
/2
/2
:1
:2
P
M
PLUMBING ENLARGED PLANS
RDC 45 88JRM
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
01/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
P-401
N
1/4" = 1'-0"
ENLARGED PLUMBING SUPPLY PLAN1
PLUMBING KEYNOTES
1 CONNECT NEW SANITARY TO EXISTING SANITARY SEWER AT THIS APPROXIMATE LOCATION.
CONTRACTOR TO VERIFY SIZE AND LOCATION.
4 2" WASTE FROM ABOVE.
6 1/2" DHW/DCW DOWN TO FIXTURE.
10 NEW WATER PIPE ROUTING TO BE COMPLIANT WITH THE VA'S LEGIONELLA DIRECTIVE 1061. REFER TO
P-501 DETAIL 8 FOR MORE INFORMATION.
12 3/4" DHW/DCW DOWN TO MOP SINK.
13 EXISTING 4" WASTE STACK.
14 2" WASTE DOWN/ 1-1/2" VENT UP FROM FLOOR DRAIN.
16 3" WASTE FROM SINKS ABOVE.
18 4" WALL CLEAN OUT.
19 CONNECT TOILET TO FIXTURE CARRIER IN CHASE.
20 2" VENT UP FROM FIXTURE.
21 ROUTE 3" UP TO FLOOR ABOVE. CONNECT TO EXISTING 3" VENT.
22 ROUTE SANITARY SEWER IN CHASE WITH MINIMUM SLOPE. PROVIDE SUPPORT AS NEEDED.
23 CONNECT FIXTURE TO EXISTING WASTE.
26 1/2" DCW DOWN TO P-608
27 1/2" DCW DOWN FOR NEW COFFEEPOT CONNECTION, STUB OUT JUST ABOVE COUNTERTOP. PROVIDE
SHUT OFF VALVES AND VACUUM BREAKERS.
29 CONNECT 1" DHW/DCW TO EXISTING RISERS UP TO FIRST FLOOR.
N
1/4" = 1'-0"
ENLARGED UNDERFLOOR PLUMBING PLAN2
N
1/4" = 1'-0"
ENLARGED PLUMBING WASTE AND VENT PLAN3
No. REVISION DESCRIPTION DATE
N
1/4" = 1'-0"
DOMESTIC PIPING DEMOLITION - ENLARGED PLAN4
N
1/4" = 1'-0"
WASTE/VENT PIPING DEMOLITION - ENLARGED PLAN5
7 1/2" [188mm]
4" [100mm]
2 1/8" [56mm]2 1/8" [56mm]
7/16" [11mm]
3/4" [19mm]
3/4" [19mm]
HOT PIPECOLD PIPE
REFER TO SPECIFICATIONS FOR INSULATION TYPES, INSULATION
THICKNESSES, HANGER TYPES, HANGER ROD CONNECTIONS TO SRUCTURE
AND HANGER SPACING.
CUT INSULATION TO FIT AROUND
HANGER. SEAL EXPOSED
INSULATION ENDS WITH JOINT
SEALANT.
PROVIDE A SECTION OF HIGH
DENSITY INSULATION OR
STYROFOAM BILLETS AT EACH
HANGER OF COLD INSULATED PIPE.
THREADED STEEL ROD WITH
NUT AND WASHER BOTH
SIDES (TYP.).
CLEVIS HANGER, SHOWN FOR CLARITY.
SIZE HANGER FOR COLD PIPE OUTSIDE
DIAMETER PLUS INSULATION THICKNESS.
DO NOT PENETRATE INSULATION WITHE
HANGER.
CLEVIS HANGER, SHOWN FOR
CLARITY. SIZE HANGER FOR HOT
PIPE OUTSIDE DIAMETER.
SECURE PIPE HANGER TO
STRUCTURE (TYP.)
PROVIDE SHORT INSULATION SHIELD
FOR LAPPING INSULATION JACKET
OVER HIGH DENSITY INSULATION OR
STYROFOAM BILLETS. MAINTAIN
VAPOR BARRIER.
OVER 20'
UP TO 20'
155 - 330
NOTE:
1. PROVIDE ACCESS WHERE DEVICES ARE CONCEALED WITHIN PARTITIONS OR ABOVE
CEILINGS. SEE SPECIFICATIONS 22 11 00 - 2.10
NEAREST DOMESTIC WATER
SUPPLY RISER
WATER HAMMER
ARRESTER
DOMESTIC WATER
SUPPLY PIPING TO
FIXTURES
NEAREST DOMESTIC WATER
SUPPLY RISER
WATER HAMMER
ARRESTER
DOMESTIC WATER
SUPPLY PIPING TO
FIXTURES
F
114 - 154E
61 - 113D
33 - 60C
12 - 32B
1 - 11A
FIXTURE UNIT RATINGMARK
WATER HAMMER ARRESTER SCHEDULE
NOTES:
1. LOCATE VTR MINIMUM 3'-0" FROM PROPERTY LINE, 10'-0" HORIZONTAL, OR 3'-0" VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, 25'-0" FROM ANY OPENING OR FRESH AIR INTAKE IN MEDICAL FACILITIES AND 1'-0" FROM ANY VERTICAL SURFACE.
2. REFER TO LOCAL CODES FOR OTHER VENT TERMINATION REQUIREMENTS.
3. LOCATE VTR MINIMUM 18" FROM ADJACENT WALL, PARAPET, EXPANSION JOINT, ROOF DRAIN, EQUIPMENT CURB, OR OTHER ROOF FEATURE
4. OFFSET IN CEILING SPACE WHERE REQUIRED TO MEET THESE CONDITIONS.
5. INSULATE LAST 6'-0" OF VENT PIPE INSIDE BUILDING PER SPECIFICATIONS.
COORDINATE INSTALLATION OF
FLASHING AND COUNTERFLASHING
ROOF INSULATION
PROVIDE FIRE STOP SEAL
BETWEEN PIPE AND SLEEVE
OR DECK.
MINIMUM 12" BELOW ROOF
ROOF DECK
CORE DRILL ROOF OR
PROVIDE SLEEVE IF
REQUIRED BY TYPE OF
ROOF DECK.
MINIMUM 12" ABOVE ROOF. EXTEND TO
HEIGHT OF PARAPET WHEN WITHIN 10' OF
PARAPET, OR ABOVE MAXIMUM LOCAL
SNOW DEPTH, WHICHEVER IS HIGHER.
ANCHOR PIPE TO
STRUCTURE.
PROVIDE PIPE INCREASER ON
SMALLER VENT WHERE CODE
REQUIRED MINIMUM VTR IS 3"
NOTE:
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITONS. REFER TO SPECIFICATIONS FOR MORE INFORMATION. PIPE AND CONDUIT OF ALL TRADES MAY BE COMBINED ON THE SAME SUPPORT CHANNEL. COORDINATE SUPPORT CHANNEL LENGTH WITH PIPING AND CONDUIT TO BE SUPPORTED. SUPPORT CHANNEL SPACING SHALL BE DETERMINED BY SMALLEST PIPE TO BE SUPPORTED. CHANNEL SUPPORT MAY BE USED AS A WALL BRACKET, ATTACH TO WALL WITH ANCHOR BOLTS PER SPECIFICATIONS. FOR HORIZONTAL INSULATED PIPING, ATTACH CLAMPS AS INDICATED ABOVE, FOR VERTICAL INSULATED PIPING, ATTACH CLAMPS TO THE PIPE AND SEAL INSULATION AT BOTH CLAMP ENDS
SUPPORT WASHERS AND
LOCKNUTS (TYP.).
UNINSULATED STEEL OR
PLASTIC PIPE.
PROVIDE PLASTIC GALVANIC
ISOLATOR FOR COPPER PIPE
(TYP.)
UNINSULATED COPPER PIPE.
COLD INSULATED PIPE.
PIPE INSULATION (TYP.)
HOT INSULATED PIPE.
PROVIDE 1-5/8"x1-5/8" 14 GA.
CHANNEL SUPPORT.
CUT INSULATION TO FIT AROUND
TRAPEZE HANGER. SEAL BOTH ENDS OF
EXPOSED INSULATION WITH JOINT
SEALANT.
PROVIDE METAL 360° INSULATION SHIELD
AND HIGH DENSITY INSULATION OR PRE-
ENGINEERED THERMAL HANGER-SHIELD
INSERT OF CALCIUM SILICATE
INSULATION. FOR PIPES 4" AND SMALLER,
PRE-ENGINEERED THERMAL HANGER-
SHIELD INSERT OF FLEXIBLE
UNICELLULAR INSULATION MAY BE
PROVIDED.
SIZE AND QUANTITY OF HANGER RODS
PER MANUFACTURER'S
RECOMMENDATIONS.
PROVIDE TWO-PIECE PIPE
CLAMP (TYP.).
1/4" Ø MOLLY BOLT HOLLOW WALL
ANCHOR (1 EA. SIDE OF LAV)
STEEL WALL PLATE
WALL ANCHOR
STUDS
STEEL HANGER BY LAV MFGR
SECTION A
PLAN
NOTE:
1. AT LAVS WITH FOOT PEDAL CONTROLS PROVIDE AN ADDITIONAL 16 GAGE GALVANIZED
STEELPLATE 12"x16" SECURED TO A MINIMUM OF 2 STUDS PER FOOT PEDAL.
2. PROVIDE 20 GAGE STUDS WHEN HEIGHT EXCEEDS 12'-0".
FOR FIXTURE HEIGHT
SEE ARCHITECTURAL
DRAWINGS
MIN. (3) 1/4" MACHINE
BOLTS W/DOUBLE LOCK
NUTS ON BACK SIDE
MIN. 5 1/4" Ø GALV. MACHINE
BOLTS WELDED TO PLATE
TYP. 1/8"
MINIMUM 16 GAGE GALVANIZED
STEELPLATE 12"x48" MIN. SECURED
TO A MIN. 4 STUDS PER LAVATORY
1/4"
A A
T O
F
LO
O R
3' -3
V A
R
IE
S
HANGER ROD
SUPPORT FOOT
INSTEAD OF USING A DOUBLE
NUT - A PIPE SLEEVE OVER
ROD MAY BE USED
LOCATION
OF PUSH
BUTTON
SPLIT GRAB BAR SEE
ARCH. DWGS
DIVERTER VALVE
[4 m m
[9 m m
[8 m m
F O
R F
IX
TU
R E
H E
IG
H
T
S E
E A
R C
H
IT
E C
T U
R A
L
D R
A W
IN
G
S
ELEVATION
FINISHED FLOOR
FINISHED WALL
[8 m m
C WATER CLOSET
PLAN
L
[450mm]
TWO GANG
ELECTRICAL BOX
W/STAINLESS STEEL
COVER PLATE
3/4" [19mm] CONDUIT[250mm]
3' -3
2' -9
2' -1
3/
8"
18"
10"
BALANCING
DEVICE
NOTES:
1. SUPPORT PUMP FROM PIPING ONLY. DO NOT SUPPORT PUMP FROM MOTOR.
BALL OR BUTTERFLY
TYP.
FLEXIBLE
CONNECTION
STRAINER
1/2"
PRESSURE GAGE
PIPE HANGERS - PROVIDE DOUBLE
DEFLECTION NEOPRENE (TYPE HN)
FORFIRST TWO ON EACH SIDE OF PUMP
(SEENOTE NO. 1)
PROVIDE A METAL SUPPORT
PLATE WHEN DRAIN IS INSTALLED
IN AN EXISTING FLOOR - CAULK
AROUND DRAIN PRIOR TO RE-
GROUTING
NOTE:
1. SLOPE MEMBRANE LINER 2% TO DRAIN.
THREADED, CAULKED OR NO-HUB
CONNECTION
FLASHING CLAMP
WITH WEEP HOLES
STRUCTURAL SLAB
TILE FLOOR
CONCRETE FILL
NICKLE BRONZE
ADJUSTABLE
STRAINER (FLUSH
WITH FINISHED
FLOOR)
CEMENT BED
LOOSE GRAVEL AT
WEEP HOLES 3mm to 6mm SIZE
WATERPROOF
MEMBRANE
CLAMP WATERPROOF
MEMBRANE INSIDE OF DRAIN
BODY TO DRAIN TO WEEP
HOLES
BATHROOM
GROUP
HOT WATER SUPPLY
COLD WATER SUPPLY
HOT WATER RETURN
COLD WATER RETURN
MV
HAND SINK
WITH TMV
WARD HAND
SINK WITH TMV
MVMVCORRIDOR
CHECK VALVE
(TYP)
ASSE 1070
MIXING VALVE
(TYP)
MAXIMUM HOT
WATER RUN LENGTH -
SEE CHAPTER 4
NOTE 3
NOTES:
1. MINIMIZE COLD AND HOT WATER FIXTURE RUN-OUT DISTANCE BY LOCATING FIXTURES AS CLOSE AS PRACTICAL
TO HOT WATER AND COLD WATER BRANCH LINES.
2. RECIRCULATION OF CW AND HW SUPPLY CLOSE TO FIXTURE IS NECESSARY WHEN MAXIMUM FIXTURE RUN-OUT
LENGTH IS EXCEEDED.
3. SUPPLY TO W.C. MAY REQUIRE SEPERATE LINE FROM CW SUPPLY WHEN W.C. NOT USED DAILY OR EXCEEDS
MAXIMUM FIXTURE RUN-OUT LENGTH. REFER TO CHAPTER 4.
PATIENT ROOM WC
TO MAIN BUILDING
WASTE DRAIN
WATERPROOF SEALANT
SLEEVE THROUGH SLAB
SEALANT BACKING
MATERIAL
FLOOR SLAB
FLOOR DRAIN WITH
TRAP PRIMER ADAPTER
1/2" TRAP PRIMER LINE
DISTRIBUTION UNIT. AVAILABLE FOR 4
ADDITIONAL LINES. PROVIDE ACCESS
PANEL BENEATH LAVATORY.
TRAP PRIMER VALVE
DOMESTIC COLD WATER (DCW) LINE
1/2" TRAP PRIMER SUPPLY SEDIMENT LOOP
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2021
EXP. 12/31/2021
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
/2
/2
:1
:2
P
M
PLUMBING DETAILS
RDC 46 88JRM
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
01/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
P-501
NTS
HANGER ROD SUPPORT FOOT DETAIL10
NTS
PIPE HANGER DETAIL7
NTS
WATER HAMMER ARRESTOR DETAIL2
NTS
VENT THROUGH ROOF DETAIL5
NTS
TRAPEZE PIPE HANGER DETAIL11
NTS
LAVATORY MOUNTING DETAIL3
NTS
INSTALLATION OF HANGAR SUPPORT FOOT6
NTS
P-103 WATER CLOSET DETAIL1
No. REVISION DESCRIPTION DATE
NTS
IN-LINE PUMPS - CONNECTIONS9
NTS
TYPE "C" FLOOR DRAIN DETAIL8
NTS
COLD WATER/ HOT WATER CONNECTION OF PLUMBING FIXTURES DETAIL4
NTS
TRAP PRIMER DETAIL12
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2021
EXP. 12/31/2021
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
/2
/2
:1
:2
P
M
PLUMBING SCHEDULES
RDC 47 88JRM
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
01/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
P-601
PLUMBING FIXTURE SCHEDULE
MARK FIXTURE
BASIS OF DESIGN PIPING ROUGH-IN WASTE FIXTURE
UNITS
WATER FIXTURE
UNITS DESCRIPTIONMANUFACTURER MODEL WASTE (IN) VENT (IN) CW (IN) HW (IN)
P-103 Water Closet, Flush Valve, Public American Standard AFWALL Millenium Flowwise 4 2 1 1/4 - 12 20 Wall hung, manual flush valve, elongated bowl, wall outlet. Sloan Regal 111-1.28 XL. Bemis Commercial Model 1655SSCT open elongated heavy duty plastic.
P-107 Water Closet, Flush Valve, Public American Standard AFWALL Millenium Flowwise 4 2 1 1/4 - 30 50 Wall hung, manual flush valve, elongated bowl, wall outlet. Sloan Regal 111-1.28 XL. Bemis Commercial Model 1655SSCT open elongated heavy duty plastic.
P-201 Urinal, Washout American Standard Trimbrook 2 2 1 - 6 10 Wall hung, manual flush valve,wall outlet. Sloan Regal 186-1.
P-202 Urinal, Washout American Standard Trimbrook 2 2 1 - 6 10 Wall hung, manual flush valve,wall outlet, mount ADA height. Sloan Regal 186-1.
P-420 Round, Drop-in Lavatory, Public American Standard Rondalyn 2 1-1/2 1/2 1/2 5 7.5 19" Round, White Drop-In Lavatory with Sensor Operated Laminar flow faucet.
P-502 Service Sink Acorn Engineering TNC24-TF2 3 2 3/4 3/4 3 4 Square front, corner terrazzo mop basin, fiat white. Includes integral stainless steel drain assembly.
P-524 Sink, CRS Elkay LR3319-3 2 1-1/2 3/4 3/4 2 2 Double compartment, counter top, self-rimming, 18 Gauge Stainless Steel. Faucet: Chicago Facuet #1102-317. Provide thermostatic tempering valve.
P-528 Sink, CRS Elkay LRAD191965PD 2 1-1/2 1/2 1/2 4 4 Single compartment, counter top, self-rimming, 18 Gauge Stainless Steel.
P-608 Electric Water Cooler Elkay LMABFTL8WS 1-1/2 1-1/2 1/2 - 0.5 0.25 Mechanically cooled, self-contained, dual height station barrier free water cooler with high low (adult/child) access. Provided with bottle filling station.
RECIRCULATION PUMP EQUIPMENT SCHEDULE
MARK
BASIS OF DESIGN
BODY MATERIAL FLOW (GPM) HEAD (FT)
CONNECTION
TYPE CONNECTION SIZE
ELECTRICAL DATA
MANUFACTURER MODEL NO. HP VOLTS/ PH FLA
DHWCP-1 Taco 2400-60-3P 26 115 VCast iron 11 Flanged 1" 1/6 1.9
| 40_P-000-PLUMBING LEGEND AND ABBREVIATIONS |
| 41_PD101-B61, GROUND LEVEL -PLUMBING DEMOLITION OVERALL PLAN |
| 42_PL101-B61, GROUND LEVEL -PLUMBING WASTE PLAN |
| 43_PP101-B61, GROUND LEVEL -PLUMBING SUPPLY PLAN |
| 44_P-301-PLUMBING ISOMETRICS |
| 45_P-401-PLUMBING ENLARGED PLANS |
| 46_P-501-PLUMBING DETAILS |
| 47_P-601-PLUMBING SCHEDULES |
File details come from the government source that posted it. Updated .