1 of 8 - 589A7-21-702 General Dwgs.pdf
PDF 3 MB Posted
- Attached to
- Y1DA--589A7-21-702 EHRM Training and Admin Support Space (TASS) Construction - Wichita, KS
- Solicitation number
- 36C77622B0033
About this file
This is a solicitation for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking a general contractor to renovate approximately 12,000 square feet on the ground level of Building 61 at the Robert J. Dole VA Medical Center in Wichita, KS. Renovations include classrooms, offices, corridors and toilet rooms. The contractor will furnish all labor, materials, equipment and supervision to complete the project in accordance with provided specifications and drawings. The closing date for responses was not included in the document.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LO NG TERMADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICACUTE INPATIENTAM BULATO RY LO NG TERMADM INISTRATIO N/SUPPO RTPRO CEDUAL/ANCILLARY / DIAG NO STICM ENTAL HEALTH
ACUTE INPATIENTAM BULATO RYM ENTAL HEALTH
3 1A 1
1C
1B
219 34
20 13 12
161110
5B
N
PROJECT LOCATION
ROBERT J DOLE VA MEDICAL CENTER CAMPUS MAP
PROJECT SCOPE AREA
BUILDING 61,
GROUND AND LEVEL 1
PROJECT SCOPE AREA
NEW PARKING LOT WITH
UTILITY HOOKUPS FOR
TEMPORARY TRAILERSREFERENCE MECHANICAL AND ELECTRICAL
DRAWINGS FOR EXTENT OF WORK ON
OTHER LEVELS OF BUILDING 61
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:0 :3
A
M
COVER SHEET
JLJ 01 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
VA PROJECT NUMBER: 589A7-21-702
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
ISSUED FOR CONSTRUCTION
GI000
SHEET INDEX
SEQ. NUMBER SHEET NAME
[07] ELECTRICAL
64 E-000 ELECTRICAL LEGEND, NOTES, AND ABBREVIATIONS
65 ES100 SITE ELECTRICAL AND TELECOM PLAN
66 ED101 B61, GROUND LEVEL, ELECTRICAL LIGHTING
DEMOLITION PLAN
67 ED102 B61, FIRST LEVEL, ELECTRICAL LIGHTING DEMOLITION
PLAN
68 ED201 B61, GROUND LEVEL - ELECTRICAL POWER
DEMOLITION PLAN
69 ED202 B61, FIRST LEVEL - ELECTRICAL POWER DEMOLITION
PLAN
70 EL101 B61, GROUND LEVEL - ELECTRICAL LIGHTING PLAN
71 EL102 B61, FIRST LEVEL - ELECTRICAL LIGHTING PLAN
72 EP101 B61, GROUND LEVEL - ELECTRICAL POWER PLAN
73 EP102 B61, FIRST LEVEL - ELECTRICAL POWER PLAN
74 EP111 B61, GROUND LEVEL - ELECTRICAL EQUIPMENT
POWER PLAN
75 EP112 B61, FIRST LEVEL - ELECTRICAL EQUIPMENT POWER
PLAN
76 EP113 B61, ROOF - ELECTRICAL EQUIPMENT POWER PLAN
77 E-500 ELECTRICAL DETAILS
78 E-600 ELECTRICAL ONE-LINE DIAGRAM
79 E-601 ELECTRICAL PANELBOARD SCHEDULES
80 E-602 ELECTRICAL PANELBOARD SCHEDULES
[08] TECHNOLOGY
81 T-000 TECHNOLOGY LEGEND, NOTES AND ABBREVIATIONS
82 TD101 B61, GROUND LEVEL - TECHNOLOGY DEMOLITION
PLAN
83 TD102 B61, FIRST LEVEL - TECHNOLOGY DEMOLITION PLAN
84 T-101 B61, GROUND LEVEL - TECHNOLOGY PLAN
85 T-102 B61, FIRST LEVEL - TECHNOLOGY PLAN
86 TY101 B61, GROUND LEVEL - SECURITY PLAN
87 TY102 B61, FIRST LEVEL - SECURITY PLAN
88 T-500 TECHNOLOGY DETAILS AND LEGENDS
TOTAL SHEETS: 88
SHEET INDEX
SEQ. NUMBER SHEET NAME
[04] FIRE PROTECTION
33 FA001 FIRE ALARM GENERAL NOTES, LEGEND, AND
DIAGRAMS
34 FA101 B61, GROUND LEVEL - FIRE ALARM AUDIBILITY PLAN
35 FA102 B61, LEVEL 1 - FIRE ALARM AUDIBILITY PLAN
36 FA103 B61, GROUND LEVEL - FIRE ALARM PLAN
37 FA104 B61, LEVEL 1 - FIRE ALARM PLAN
38 FX101 B61 - GROUND LEVEL - FIRE SUPPRESSION HAZARD
CLASSIFICATION PLAN
39 FX102 B61 -LEVEL 1 - FIRE SUPPRESSION HAZARD
CLASSIFICATION PLAN
[05] PLUMBING
40 P-000 PLUMBING LEGEND AND ABBREVIATIONS
41 PD101 B61, GROUND LEVEL - PLUMBING DEMOLITION
OVERALL PLAN
42 PL101 B61, GROUND LEVEL - PLUMBING WASTE PLAN
43 PP101 B61, GROUND LEVEL - PLUMBING SUPPLY PLAN
44 P-301 PLUMBING ISOMETRICS
45 P-401 PLUMBING ENLARGED PLANS
46 P-501 PLUMBING DETAILS
47 P-601 PLUMBING SCHEDULES
[06] MECHANICAL
48 M-000 MECHANICAL LEGEND AND ABBREVIATIONS
49 MD101 B61, GROUND LEVEL - MECHANICAL HVAC DEMOLITION
PLAN
50 MD102 B61, LEVEL 1 - MECHANICAL HVAC DEMOLITION PLAN
51 MD103 B61, LEVEL 1 - MECHANICAL PIPING DEMOLITION PLAN
52 MD104 B61, LEVEL 1 AND ROOF - MECHANICAL DUCT
DEMOLITION PLAN
53 MP101 B61, GROUND LEVEL - MECHANICAL PIPING PLAN
54 MP102 B61, LEVEL 1 - MECHANICAL PIPING PLAN
55 MH101 B61, GROUND LEVEL - MECHANICAL HVAC PLAN
56 MH102 B61, LEVEL 1 AND ROOF - MECHANICAL HVAC PLAN
57 M-201 MECHANICAL FLOW DIAGRAMS
58 M-301 MECHANICAL SECTIONS
59 M-401 MECHANICAL ENLARGED PLANS
60 M-501 MECHANICAL DETAILS
61 M-601 MECHANICAL SCHEDULES
62 M-701 MECHANICAL CONTROLS
63 M-702 MECHANICAL CONTROLS CONT.
SHEET INDEX
SEQ. NUMBER SHEET NAME
[01] GENERAL
01 GI000 COVER SHEET
02 GI001 GENERAL INFORMATION
03 GI010 B61 - PHASING PLANS
04 GI011 B61 - OCCUPANCY PLAN
05 GI012 B61 - LIFE SAFETY PLAN
[02] CIVIL
06 CS000 CIVIL LEGEND & ABBREVIATIONS
07 CS101 CIVIL SITE LAYOUT
08 CS002 CIVIL DIMENSION LAYOUT
09 CS003 CIVIL GRADING LAYOUT
10 CS004 CIVIL UTILITY LAYOUT
11 CS005 CIVIL SWPPP LAYOUT
12 CS401 CIVIL PAVEMENT DETAILS
13 CS402 CIVIL DRAINAGE DETAILS
14 CS403 CIVIL UTILITY DETAILS
15 CS404 CIVIL SWPPP DETAILS
[03] ARCHITECTURAL
16 AS100 ARCHITECTURAL SITE PLAN
17 AD100 B61, GROUND LEVEL - DEMOLITION FLOOR PLAN
18 AD101 B61, LEVEL 1 - DEMOLITION FLOOR PLAN
19 AD200 B61, GROUND LEVEL - DEMOLITION CEILING PLAN
20 AD201 B61, LEVEL 1 - DEMOLITION CEILING PLAN
21 AE021 PARTITION TYPES
22 AE100 B61, GROUND LEVEL - REFERENCE PLAN
23 AE101 B61, LEVEL 1 - REFERENCE PLAN
24 AE102 B61, GROUND LEVEL - FF&E FLOOR PLAN
25 AE103 B61, LEVEL 1 - FF&E FLOOR PLAN
26 AE104 B61, GROUND LEVEL - FINISH FLOOR PLAN
27 AE105 B61, LEVEL 1 - FINISH FLOOR PLAN
28 AE200 B61, GROUND LEVEL - REFLECTED CEILING PLAN
29 AE201 B61, LEVEL 1 - REFLECTED CEILING PLAN
30 AE400 ARCHITECTURAL ENLARGED PLANS AND INTERIOR
ELEVATIONS
31 AE500 MILLWORK SECTIONS
32 AE601 DOOR SCHEDULE & DETAILS
No. REVISION DESCRIPTION DATE
ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS
TOILET ROOM TURNING
RADIUS
CLEAR FLOOR SPACE
@ WATER CLOSET
5'-6"
6' -0
2'-6"
4' -0
2'-6"
4' -0
FIXTURE MOUNTING HEIGHTS AND CLEARANCES
18" MIN
M
IN
FRONT APPROACH,
PULL SIDE
36" MIN
M
IN
HINGE APPROACH,
PULL SIDE
HINGE APPROACH,
PULL SIDE
*12" MIN
M
IN
FRONT APPROACH,
PUSH SIDE
M
IN
HINGE APPROACH,
PUSH SIDE
22" MIN 24" MIN
*4 8"
M
IN
LATCH APPROACH,
PULL SIDE
24" MIN*4
2"
M
IN
LATCH APPROACH,
PUSH SIDE
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
*54" MIN IF CLOSER
IS PROVIDED
*48" IF CLOSER IS
PROVIDED
FRONT APPROACH,
PUSH SIDE
M
IN
42" MIN
M
IN
DOOR AND FIXTURE CLEARANCES
MATERIALS LEGEND
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE
TECHNICAL INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• 2021 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)
• 2021 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• 2021 NATIONAL FIRE CODES (NFPA)
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• 2020 VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• 2020 NATIONAL ELECTRICAL CODE (NEC)
• 2021 INTERNATIONAL PLUMBING CODE (IPC)
• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)
• 2017 ANSI ICC A117.1 ACCESIBLE AND USABLE BUILDINGS AND FACILITIES
• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)
• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL
BUILDINGS AND NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS
• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER
CONSTRUCTION SPECIFICATION.
• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1
• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE.
FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE
DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA.
THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
ASHRAE 90.1 - 2019 EDITION
BUILDING LOCATION: WITCHITA, KS
CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 4A
INTERIOR DESIGN CONDITIONS:
THE INTERIOR DESIGN TEMPERATURES FOR HEATING AND COOLING AS DEPICTED IN THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL DRAWINGS SHALL BE THE MAXIMUM AND MINIMUM
VALUES FOR THE ASSOCIATED TEMPERATURE CONTROL ZONES.
BUILDING ENVELOPE REQUIREMENTS (TABLE 5.5-4):
ROOFS: REQUIRED: DESIGNED:
INSULATION ABOVE DECK R-30 c.i. EXISTING METAL BUILDINGS: R-19 + R-11 Ls or R-25 + R-8 Ls EXISTING
ATTIC AND OTHER: R-49 EXISTING
WALLS, ABOVE GRADE
MASS: R-9.5 c.i. EXISTING METAL BUILDING: R-0 + R-15.8 c.i. EXISTING STEEL-FRAMED: R-13 + R-7.5 c.i. EXISTING WOOD-FRAMED AND OTHER: R-13 + R-3.8 c.i. or R-20 EXISTING
WALL, BELOW GRADE
BELOW-GRADE WALL: R-7.5 c.i. EXISTING
FLOORS
MASS: R-14.6 c.i. EXISTING
STEEL-FRAMED: R-30 EXISTING
WOOD-FRAMED AND OTHER: R-30 EXISTING
SLAB-ON-GRADE FLOORS
UNHEATED SLABS: R-15 FOR 24 in. EXISTING HEATED SLABS: R-20 for 24 in. EXISTING
OPAQUE DOORS
SWINGING: U-0.370 EXISTING
NONSWINGING: U-0.310 EXISTING
VERTICAL FENESTRATION, U-FACTOR
NON-METAL FRAMING (ALL): U-0.31 EXISTING
METAL FRAMING, FIXED: U-0.36 EXISTING
METAL FRAMING, OPERABLE: U-0.45 EXISTING
METAL FRAMING, ENTRANCE DOOR: U-0.63 EXISTING
SKYLIGHT, 0% TO 3% OF ROOF, U-FACTOR
ALL TYPES: U-0.50 EXISTING
ENERGY REQUIREMENTS
N
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL
CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF
THE ENTIRE DOCUMENT SET.
2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING
ANY WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD
VERIFY ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE
KEPT CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF
THE CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO
SEPARATE WORK AREAS FROM THE EXISTING FACILITIES.
5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO
REMAIN IN PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR,
PATCH AND REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE
REPAIRED OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL
COST TO THE OWNER.
8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO
PREVENT PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING
SPACES.
9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO
PROVIDE ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH
OTHER DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS.
DRAWINGS, AS A WHOLE, REPRESENT A COMPLETE SET AND DEPICT
REQUIREMENTS FOR COMPLETE AND OPERATIONAL SYSTEMS. INDIVIDUAL
DRAWINGS MAY NOT DEPICT COMPLETE AND ACCURATE INFORMATION TO
COORDINATE COMPLETE AND OPERATIONAL SYSTEMS, BUT DO SO AS AN ENTIRE
DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL DRAWINGS.
CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE OTHER
SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION
DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND
OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND
SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND
OPERATIONAL SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD,
IDENTIFIED IN THE DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY
AN ADDITIONAL COST TO THE GOVERNMENT.
11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH
SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN
ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE,
EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR
INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60
CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS
DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH
OTHER MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE
DISCIPLINE MORE THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION
SCHEDULE UNLESS REQUESTED IN WRITING AND APPROVED BY THE COR.
CONTRACTOR WILL BE ADVISED, IN WRITING, OF APPROVAL OF REQUEST, OR OF
WHICH OTHER DATE AND/OR TIME SUCH INTERRUPTION WILL CAUSE THE LEAST
INCONVENIENCE TO OPERATIONS OF THE MEDICAL CENTER. INTERRUPTION TIME
APPROVED BY THE MEDICAL CENTER MAY OCCUR AT TIMES OTHER THAN
CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE INTERRUPTION MAY BE
ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN ADDITIONAL COST TO THE
GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY AFFECT THE
NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING THE
CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT.
SPUR DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS
CONTAINING BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP)
PRODUCTS WERE DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE
CONSTRUCTION DOCUMENTS.
13. REFER TO THE DESIGN BINDER FOR THE ICRA INFORMATION DOCUMENTATION.
14. ANY CONSTRUCTION ACTIVITY THAT IMPACTS THE FIRE OR SMOKE RATING OF
EXISTING WALLS SHALL BE PROPERLY REPAIRED AND FIRESTOPPED AS
REQUIRED TO MAINTAIN THE EXISTING RATING.
GENERAL NOTES
AREA NAME
150 SF
A101
A101
SIM
00000
00.0
A101
1 1
A101
LEVEL NAME
00'-00"
00'-00"
4B
3A
ROOM NAME
000A
150 SF
/1 A101 X0000
ROOM TAG
AREA TAG
SPECIALTY EQUIPMENT TAG
DOOR TAG
KEYED NOTE TAG
WALL TAG
WINDOW TAG
A101
SIM
A101
SIM
REFERENCE SYMBOLS IDENTIFICATION TAGS
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
GRID HEAD AND
LINE
LEVEL INDICATOR
MATCH LINE AND
VIEW REFERENCE
NORTH ARROW W/
PROJECT NORTH
SPOT ELEVATION
DETAIL
SECTION
**48" MIN IF BOTH CLOSER
AND LATCH PROVIDED
WALL
SECTION
BUILDING
SECTION
DETAIL
ELEVATION
INTERIOR
ELEVATION
BUILDING
ELEVATION
1 1
6'- 0"
5'- 6"
BARIATRIC TOILET ROOM
TURNING RADIUS
CLEAR FLOOR SPACE
@ ADA LAVATORY
CLEAR FLOOR SPACE
@ ADA DRINKING
FOUNTAIN
4' -0
M
A X
4' -0
M
A X
2' -1
0" M
A X
2' -5
M
IN
1'-6" MIN
1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT
BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,
FIXTURES, AND EQUIPMENT.
2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN
COUNTERTOPS - 36"-48" MAX ON CENTER.
3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER
FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.
4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR
FIXTURE TYPES USED IN THIS PROJECT.
5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,
BACKING TO BE PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.
6" MAX
9" M
IN
SHOWER
DRINKING
FOUNTAIN
PAPER TOWEL
DISPENSER
SANITARY
NAPKIN
DISPENSER
4' -0
"M A
X
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
4' -0
M
A X
SOAP
DISPENSER
2' -1
0" M
A X
T O
B .O
. R E
F
LE
C T
IV
E
S U
R F
A C
E
3' -4
M
A X
17 MIN
2' -3
M
IN
3' -0
M
A X
1'-6" MIN
WALL
2' -9
" 4' -0
M
IN
2'-0" MIN
8" MIN
WALL
LAVATORY
WITH APRON
1' -5
M
A X
1'-6" MIN
URINAL
WALL
1'-5" - 1'-7" (AMBULATORY)
1'-4" - 1'-6" (WHEELCHAIR)
CLEAR FLOOR
5'-6"
CLEAR FLOOR
6'-0"
3'-0" MIN
2' -9
3' -0
1'-0" MIN
3'-6" MIN 1'-0"MAX
4'-6" MIN
1' -5
'-7
1' -6
M
IN
A N
S I I
C C
A
7.
1)
1' -3
M
IN
A D
A /A
B A
2' -9
'-0
WALL
WALL
4' -0
M
A X
WALL HOOK
6' -6
CLOCK
WALL
FINISHED FLOOR
FIRE EXTINGUISHER
CABINET
WEIGHT > 40LBS
FIRE EXTINGUISHER
CABINET
WEIGHT < 40LBS
4' -0
"M A
X
4' -0
M
A X
TOILET SEAT
COVER
DISPENSER
BABY
CHANGING
STATION
HANDRAILS AND
BUMPERGUARDS
6"
3' -0
M
A X
4"
6"
3"
6"
M
IN
1' -6
6" MAX
7" - 9" 11" MIN
17" - 25"
(ANSI ICC A117.1)
39"- 41"
(A N
S I I
C C
A
7.
1)
M
IN
(A N
S I I
C C
A
7.
1)
1"
3' -6
M
A X
5' -0
M
A X
FIBERGLASS BATT
INSULATION
RIGID INSULATION
CONCRETE / PRECAST
CONCRETE
EARTH / SOIL
SAND, EIFS FINISH, OR
PLASTER FINISH
GYPSUM BOARD FINISH
BRICK
CONCRETE MASONRY
UNIT
STONE / CAST STONE
GYPSUM BOARD SECTION
EXTERIOR SHEATHING
BOARD SECTION
PLYWOOD SECTION
A
ACB ACOUSTIC CEILING BAFFLE
ACP ACOUSTIC CEILING PANEL
ACST ACOUSTIC
ADA AMERICANS WITH DISABILITIES ACT
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
AE ARCHITECT/ENGINEER
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINIUM (TRIM)
AMT AMOUNT
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AT ACOUSTIC CEILING TILE
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BTWN BETWEEN
C
CAB CABINET
CAV CAVITY
CBB CONCRETE BACKER BOARD
CD CONSTRUCTION DOCUMENTS
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CH BD CHALK BOARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CONTRACTOR PROVIDED
CP/CI CONTRACTOR PROVIDED /
CONTRACTOR INSTALLED
CPT CAROET/CARPET TILE
CS CONCRETE SEALED
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR CENTER
CU FT CUBIC FEET
D
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWP DIMENSIONAL WALL PANEL
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPY EPXOY FLOORING
EQ EQUAL
ETR EXISTING TO REMAIN
EX EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FAB FABRIC
FED FEDERAL
FF FINISH FACE
FE FINISHED END
FF EL FINISH FLOOR ELEVATION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FP FIRE PROTECTION
FR FIRE RESISTANT
FT FEET
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G
GDR GUARDRAIL
GL GLASS/GLAZING
GRAN GRANITE
GR FL GROUND FLOOR
GT GROUT
GSM GALVANIZED SHEET METAL
GYP BD GYPSUM BOARD
H
HDW HARDWARE
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
I
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J
J-BOX JUNCTION BOX
L
LAV LAVATORY
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIN LINEAR
LN LINOLEUM
LOC LOCATION
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M
MAT CARPET MAT / WALK-OFF MAT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MVBL MOVABLE
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P
P PAINT
PA PUBLIC ADDRESS
PBD PARTICLE BOARD
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRB PROFILE BASE
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PORCELAIN TILE
PWR POWER
Q
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
R
RAF RESILIENT ATHETIC FLOORING
RB RUBBER BASE/RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RES RESINOUS FLOORING
RES-W RESINOUS / EPOXY
WALL / CEILING
RF RUBBER FLOORING
RFG ROOFING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RSF RESILIENT SHEET FLOORING
RV ROOF VENT
RWC RIGID VINYL WALLCOVERING
S
SC SPECIALTY COATING
SD STATIC DISSIPATIVE
FLOORING/TILE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SIM SIMILAR
SJ SCORED JOINT
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SOLID SURFACE
ST STONE
STD STANDARD
STOR STORAGE
SV SHEET VINYL (ROLLED OR TILE)
T
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZO
TOF TOP OF FOOTING/ FOUNDATION
TOM TOP OF MASONRY
TOS TOP OF SLAB/ STEEL
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VAR VARIES
VC VA PROVIDED / CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE
VFAT VINYL FACED ACOUSTICLAL TILE
VP VENEERED PLASTER
VT VINYL TILE
VV VA PROVIDED / VA INSTALLED
VWC VINYL WALLCOVERING
VWF VINYL WALL FABRIC
W
W/ WITH
W/O WITHOUT
W/C WATER CLOSET
WC WHEELCHAIR
WD WOOD
WFAB WALL FABRIC
WPM WATERPROOF MEMBRANE
WSF WELDED SHEET FLOOR
X
X BRACE CROSS BRACE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:0 :3
A
M
GENERAL INFORMATION
DLB 02 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
GI001
UP
A
B C D E F G
426 SF
WAITING
006A
404 SF
OFFICE
001D
805 SF
CLASSROOM
004A
CORRIDOR
001-3
363 SF
BREAK
006B
812 SF
CLASSROOM
003B
857 SF
CLASSROOM
002B
1099 SF
OFFICE
T O
IL
E
T
W
TOILET (M)
STAIR
NORTH
CORRIDOR
001-2
C O
F F
E E
E L
E C
1B
ELEV
NORTH
ELEV
SOUTH
STAIR
SOUTH
806 SF
CLASSROOM
005A
806 SF
CLASSROOM
002A
800 SF
CLASSROOM
003A
806 SF
CLASSROOM
004B
840 SF
CLASSROOM
005B
575 SF
OFFICE
001A
S T
O R
1C
WAITING
001E
122 SF
TELECOM
008A
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
FV
20'-0"
FV
26'-0"
FV
133'-0"
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
6'
-0
CONFERENCE ROOM
008F
OFFICE
008C
FISCAL SERVICE
DIRECTOR
OFFICE
008C
OFFICE
020E
OFFICE
020D
OFFICE
020C
OFFICE
020B
OFFICE
020A
VESTIBULE
020-61
BREAK
020G
UNION OFFICE
011A
UNION OFFICE
011 CANTEEN STORAGE
009-61
ELECTRICAL
LOADING DOCK
CORRIDOR
CORR
MECHANICAL ROOM
CORRIDOR
SERVER ROOM
015B
IRM
STOR
015A
HAC
RESTROOM
RESTROOM
ELEVATOR ROOM
COMPUTER LAB
OFFICE
ELEV CONTROL
CORRIDOR
A
B C D E F G
816 SF
CLASSROOM
106A
514 SF
CLASSROOM
798 SF
CLASSROOM
106B
802 SF
CLASSROOM
107A
797 SF
CLASSROOM
107B
879 SF
CLASSROOM
246 SF
CONFERENCE
374 SF
CORRIDOR
TLT
TLT
VESTIBULE
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
FV
20'-0"
FV
26'-0" FV
133'-0"
F V
'-0
F V
'-0
F V
'-0
'-0
'-0
'-0
'-0
'-0
'-0
F V
8'
-0
VETERAN'S SERVICE
CORRIDOR
TELECOM
OFFICE
129B
COMPUTER LAB
129A
CONFERENCE
CONFERENCE
126E
OFFICE
126D
DIRECTOR'S SUITE
OFFICE
126F
OFFICE
126C
KITCH
126B
OFFICE
126A
OFFICE
123C
OFFICE
123A
OFFICE
123D
SECRETARY
123B
OFFICE
123E
DIRECTOR'S SUITE
OFFICE
NURSE
121 HAC
TLT
TLT
MECH ROOM
VOC REHAB
116 113
CLINIC
CLINIC
115A
OFFICE
111C
OFFICE
111B
OFFICE
111A
PHYSICAL PATIENT
ACCURE
OFFICE
111D111E
OFFICE
DISABLED AMERICAN
VETERANS
MILITARY OF THE PURPLE
ORDER HEART
124A
AM VETS
124B
VFW
VETERAN'S OF AMERICA
PARALYZED OFFICE
KANSAS COMMISSION
VETERAN'S AFFAIRS
QUALITY ASSURANCE
TLT
TLT
ELEV
SOUTH
STAIR
SOUTH
STAIR
NORTH
ELEV
NORTH
PHASING PLAN LEGEND
PHASE 1 - LEVEL ONE & LIMITED GROUND FLOOR RENOVATION
• CONSTRUCT LIMITED LEVEL ONE RENOVATION SCOPE INCLUDING
CLASSROOM, CONFERENCE, AND CORRIDOR SPACES.
• CONSTRUCT GROUND FLOOR TOILET ROOMS 176 & 177.
PHASE 2 - GROUND FLOOR RENOVATION
• CONSTRUCT THE REMAINING GROUND FLOOR RENOVATION SCOPE
INCLUDING BUT NOT LIMITED TO CLASSROOM, OFFICE, & CORRIDOR SPACES.
PROJECT SCOPE WITH UNDEFINED PHASING - NEW PARKING AREA
• CONSTRUCT THE CAMPUS EAST PARKING AREA WITH TRAILER UTILITY
HOOK-UPS. REFERENCE ARCHITECTURAL SITE PLAN SHEET AS100 FOR
MORE INFORMATION.
1. THE ADJACENT PHASING PLANS ILLUSTRATE GENERAL SCOPE OF EACH PHASE AND ARE TO BE
REFERENCED FOR OVERALL PHASING INTENT. CONTRACTOR SHALL CONFIRM ALL CONSTRUCTION
ACTIVITIES MEET THE PHASING INTENT AS SHOWN ON THIS SHEET.
2. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE
CONSTRUCTION WORK WITHIN EACH PHASE OF CONSTRUCTION. PROVIDE DUST PROOFING
ENCLOSURES TO SEPARATE WORK AREAS FROM EXISTING FACILITIES AND FUTURE WORK AREAS.
3. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN PLACE
DURING THE CURRENT PHASE OF CONSTRUCTION. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
GENERAL PHASING NOTES
BUILDING 61 KEY PLAN - GROUND FLOOR
PHASE 2
RENOVATED
TRAINING AND
OFFICE SPACE
N
PHASE 2
RENOVATED
OFFICE SPACE
OUT OF SCOPE
PHASE 1
RESTROOMS
BUILDING 61 KEY PLAN - FIRST FLOOR
PHASE 1
RENOVATED
TRAINING AND
OFFICE SPACE
NOUT OF SCOPE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:0 :4
A
M
B61 - PHASING PLANS
ZDL 03 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
GI010
No. REVISION DESCRIPTION DATE
N
3/32" = 1'-0"
BLDG 61 - GROUND LEVEL - PHASING PLAN1
N
3/32" = 1'-0"
BLDG 61 - LEVEL 1 - LIFE SAFETY PLAN2
NFPA 101-2021 EDITION
BUILDING HEIGHT: EXISTING 2 STORY BUILDING, APPROXIMATELY 25'-0" HEIGHT
BUILDING AREA LIMITATION: N/A (EXISTING BUILDING)
BUILDING IS EQUIPPED WITH A FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT
CONSTRUCTION TYPE (TABLE A.8.2.1.2): TYPE II (000)
FIRE RESISTANCE RATINGS (NFPA 220 TABLE 4.1.1):
• COLUMNS: 0 HR
• BEAM, GIRDERS, TRUSSES: 0 HR
• FLOOR/CEILING ASSEMBLIES: 0 HR
• ROOF/CEILING ASSEMBLIES: 0 HR
• EXTERIOR NON-BEARING WALLS: 0 HR
• INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
• NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK, EXTERIOR
NON-BEARING WALLS, INTERIOR NON-BEARING WALLS (U.N.O. AT EXTERIOR)
MIXED-USE NON-SEPARATED ON GROUND FLOOR:
• CHAPTER 39: EXISTING BUSINESS OCCUPANCY
OCCUPANT LOADS (TABLE 7.3.1.2):
• BUSINESS USE = 150 SF/PERSON
• BUSINESS USE (CONCENTRATED) = 50 SF/PERSON
• BUSINESS USE (COLLABORATION ROOMS GREATER THAN 450 SQ FT) = 15 SF/PERSON
• BUSINESS USE (COLLABORATION ROOMS LESS THAN 450 SQ FT) = 30 SF/PERSON
• ASSEMBLY USE LESS CONCENTRATED USE, WITHOUT FIXED SEATING = 15 NET SF/PERSON
• ACCESSORY STORAGE/ MECHANICAL EQUIPMENT ROOM = 500 SF/PERSON
EXISTING BUSINESS OCCUPANCY:
• DEAD END CORRIDOR MAXIMUM DISTANCE: 50' (39.2.5.2)
• MAXIMUM COMMON PATH OF TRAVEL: 100' (39.2.5.3.1)
• MAXIMUM TRAVEL DISTANCE: 300' (39.2.6.3)
• CORRIDOR MINIMUM FIRE RATING: 0 HR (38.3.6.1 EXCEPTION 3)
ALL EXIT DOORS PROVIDED ARE 36" LEAF MINIMUM YIELDING 34" CLEAR EXIT WIDTH.
• .2"/PERSON (TABLE 7.3.3.1) ALLOWS 170 OCCUPANT LOAD PER DOOR MAX.
STAIR DOOR WIDTH PROVIDED IS 36"
• .3"/PERSON (7.3.3.2) ALLOWS 113 OCCUPANT LOAD AT STAIR, MAX.
PROTECTED AREAS:
• STORAGE ROOMS - REQUIRED VA FIRE PROTECTION DESIGN MANUAL 3.1.A AND PER NFPA 101:
39.3.2.1 AND 8.7 SMOKE PARTITIONS WITH SPRINKLER PROTECTION, PROVIDED.
LIFE SAFETY REQUIREMENTS
OCCUPANCY TYPE LEGEND
REQUIRED PLUMBING COUNT - GROUND LEVEL
OCCUPANCY
CLASSIFICATION
BUSINESS AREA
OCCUPANT
LOAD
MEN = 211
WOMEN = 212
WATER CLOSETS
(1/25 FOR FIRST 50)
(1/50 OVER 50)
6 WATER CLOSETS
LAVATORY
(1/40 FOR FIRST 80)
(1/80 OVER 80)
4 LAVS
4 LAVS
PLUMBING COUNT - FIRST LEVEL
OCCUPANCY
CLASSIFICATION
BUSINESS AREA
OCCUPANT
LOAD
MEN = 119
WOMEN = 119
WATER CLOSETS
(1/25 FOR FIRST 50)
(1/50 OVER 50)
4 WATER CLOSETS
4 WATER CLOSETS
LAVATORY
(1/40 FOR FIRST 80)
(1/80 OVER 80)
3 LAVS
3 LAVS
6 WATER CLOSETS
A
B C D E F G
2308 SF
BUSINESS USE,
CONCENTRATED
ASSEMBLY USE, LESS
CONCENTRATED
BUSINESS USE
BUSINESS USE,
COLLABORATION
BUSINESS USE, CONCENTRATED
BUSINESS USE, NIC
STORAGE USE
STORAGE USE, NIC
1658 SF
BUSINESS USE,
COLLABORATION
3387 SF
BUSINESS USE,
CONCENTRATED
1293 SF
BUSINESS USE
142 SF
STORAGE USE
126 SF
STORAGE USE
1110 SF
BUSINESS USE,
CONCENTRATED
436 SF
BUSINESS USE,
CONCENTRATED
1296 SF
ASSEMBLY USE, LESS
CONCENTRATED
546 SF
BUSINESS USE
9354 SF
BUSINESS USE, NIC
CLASSROOM
002B
BREAK
006B
OFFICE
001D
OFFICE
C O
R R
ID
O
R
1-
CORRIDOR
001-3
TOILET (M)
TOILET (W)
CLASSROOM
005A
CLASSROOM
004A
CLASSROOM
003B
WAITING
006A
C O
F F
E E
CLASSROOM
002A
CLASSROOM
003A
CLASSROOM
004B
CLASSROOM
005B
ELEC
001B
STOR.
001C
OFFICE
001A
WAITING
001E
CORRIDOR
001-1
CONFERENCE ROOM
008F
OFFICE
008C
FISCAL SERVICE
DIRECTOR
OFFICE
008C
OFFICE
020E
OFFICE
020D
OFFICE
020C
OFFICE
020B
OFFICE
020A
VESTIBULE
020-61
BREAK
020G
UNION OFFICE
011A
UNION OFFICE
011 CANTEEN STORAGE
009-61
ELECTRICAL
LOADING DOCK
CORRIDOR
CORR
MECHANICAL ROOM
CORRIDOR
SERVER ROOM
015B
IRM
STOR
015A
HAC
RESTROOM
RESTROOM
ELEVATOR ROOM
COMPUTER LAB
775 SF
STORAGE USE, NIC
1799 SF
STORAGE USE, NIC
OFFICE
ELEV
NORTH
ELEV CONTROL
F E
C
FEC
FEC
F E
C
F E
C
FEC
FEC
FEC
FEC
F E
C
FEC
STAIR
SOUTH
ELEV
SOUTH
STAIR
NORTH
FEC
FEC
FEC
FEC
TELECOM
008A
A
B C D E F G
VETERAN'S SERVICE
CORRIDOR
TELECOM
OFFICE
129B
COMPUTER LAB
129A
CONFERENCE
CONFERENCE
126E
OFFICE
126D
DIRECTOR'S SUITE
OFFICE
126F
OFFICE
126C
KITCH
126B
OFFICE
126A
OFFICE
123C
OFFICE
123A
OFFICE
123D
SECRETARY
123B
OFFICE
123E
DIRECTOR'S SUITE
OFFICE
NURSE
121 HAC
TLT
TLT
MECH ROOM
VOC REHAB
116 113
CLINIC
CLINIC
115A
OFFICE
111C
OFFICE
111B
OFFICE
111A
PHYSICAL PATIENT
ACCURE
OFFICE
111D111E
OFFICE
DISABLED AMERICAN
VETERANS
MILITARY OF THE PURPLE
ORDER HEART
124A
AM VETS
124B
VFW
VETERAN'S OF AMERICA
PARALYZED OFFICE
KANSAS COMMISSION
VETERAN'S AFFAIRS
QUALITY ASSURANCE
TLT
TLT
816 SF
CLASSROOM
106A
798 SF
CLASSROOM
106B
802 SF
CLASSROOM
107A
797 SF
CLASSROOM
107B
879 SF
CLASSROOM
374 SF
CORRIDOR
514 SF
CLASSROOM
246 SF
CONFERENCE
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
FV
20'-0"
FV
26'-0" FV
133'-0"
F V
'-0
F V
'-0
F V
'-0
'-0
'-0
'-0
'-0
'-0
'-0
F V
8'
-0
4278 SF
BUSINESS USE,
CONCENTRATED
4278 SF
BUSINESS USE,
CONCENTRATED
19896 SF
BUSINESS USE, NIC
1225 SF
STORAGE USE, NIC
782 SF
BUSINESS USE,
CONCENTRATED
392 SF
BUSINESS USE
F E
C
FEC
FEC
ELEV
NORTH
STAIR
NORTH
STAIR
SOUTH
ELEV
SOUTH
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:0 :4
A
M
B61 - OCCUPANCY PLAN
JLJ 04 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
GI011
No. REVISION DESCRIPTION DATE
N
3/32" = 1'-0"
BLDG 61 - GROUND LEVEL - OCCUPANCY PLAN4
N
3/32" = 1'-0"
BLDG 61 - LEVEL 1 - OCCUPANCY PLAN5
OCCUPANCY LOAD TABLE
OCCUPANCY USE AREA
PER TABLE 7.3.1.2.
OCC. LOAD
FACTOR IN SF
OCC.
LOAD
GROUND
ASSEMBLY USE, LESS CONCENTRATED 1296 SF 15 SF 86.4
BUSINESS USE 1293 SF 150 SF 8.6
BUSINESS USE 546 SF 150 SF 3.6
BUSINESS USE, COLLABORATION 1658 SF 15 SF 110.5
BUSINESS USE, CONCENTRATED 2308 SF 50 SF 46.2
BUSINESS USE, CONCENTRATED 3387 SF 50 SF 67.7
BUSINESS USE, CONCENTRATED 1110 SF 50 SF 22.2
BUSINESS USE, CONCENTRATED 436 SF 50 SF 8.7
BUSINESS USE, NIC 9354 SF 150 SF 62.4
STORAGE USE 142 SF 500 SF 0.3
STORAGE USE 126 SF 500 SF 0.3
STORAGE USE, NIC 775 SF 500 SF 1.6
STORAGE USE, NIC 1799 SF 500 SF 3.6
422.1
LEVEL 1
BUSINESS USE 392 SF 150 SF 2.6
BUSINESS USE, CONCENTRATED 782 SF 50 SF 15.6
BUSINESS USE, CONCENTRATED 4278 SF 50 SF 85.6
BUSINESS USE, NIC 19896 SF 150 SF 132.6
STORAGE USE, NIC 1225 SF 500 SF 2.5
238.9
661.0
ROOM NAME
000A
AREA IS NOT IN CONTRACT
EXISTING WALLS TO REMAIN
NEW DOOR / DOOR TAG
ROOM TAG / ROOM NUMBER
0.
FEC
AED
FIRE EXTINGUISHER CABINET
AUTOMATED EXTERNAL DEFIBRILLATOR
EXIT LIGHT / SIGN
BUILDING EXIT
EGRESS PATH
MOST REMOTE POINT IN ROOM
LIFE SAFETY LEGEND
DEMOUNTABLE PARTITION
NFPA 101-2021 EDITION
BUILDING HEIGHT: EXISTING 2 STORY BUILDING, APPROXIMATELY 25'-0" HEIGHT
BUILDING AREA LIMITATION: N/A (EXISTING BUILDING)
BUILDING IS EQUIPPED WITH A FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT
CONSTRUCTION TYPE (TABLE A.8.2.1.2): TYPE II (000)
FIRE RESISTANCE RATINGS (NFPA 220 TABLE 4.1.1):
• COLUMNS: 0 HR
• BEAM, GIRDERS, TRUSSES: 0 HR
• FLOOR/CEILING ASSEMBLIES: 0 HR
• ROOF/CEILING ASSEMBLIES: 0 HR
• EXTERIOR NON-BEARING WALLS: 0 HR
• INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
• NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK, EXTERIOR
NON-BEARING WALLS, INTERIOR NON-BEARING WALLS (U.N.O. AT EXTERIOR)
MIXED-USE NON-SEPARATED ON GROUND FLOOR:
• CHAPTER 39: EXISTING BUSINESS OCCUPANCY
OCCUPANT LOADS (TABLE 7.3.1.2):
• BUSINESS USE = 150 SF/PERSON
• BUSINESS USE (CONCENTRATED) = 50 SF/PERSON
• BUSINESS USE (COLLABORATION ROOMS GREATER THAN 450 SQ FT) = 15 SF/PERSON
• BUSINESS USE (COLLABORATION ROOMS LESS THAN 450 SQ FT) = 30 SF/PERSON
• ASSEMBLY USE LESS CONCENTRATED USE, WITHOUT FIXED SEATING = 15 NET SF/PERSON
• ACCESSORY STORAGE/ MECHANICAL EQUIPMENT ROOM = 500 SF/PERSON
EXISTING BUSINESS OCCUPANCY:
• DEAD END CORRIDOR MAXIMUM DISTANCE: 50' (39.2.5.2)
• MAXIMUM COMMON PATH OF TRAVEL: 100' (39.2.5.3.1)
• MAXIMUM TRAVEL DISTANCE: 300' (39.2.6.3)
• CORRIDOR MINIMUM FIRE RATING: 0 HR (38.3.6.1 EXCEPTION 3)
ALL EXIT DOORS PROVIDED ARE 36" LEAF MINIMUM YIELDING 34" CLEAR EXIT WIDTH.
• .2"/PERSON (TABLE 7.3.3.1) ALLOWS 170 OCCUPANT LOAD PER DOOR MAX.
STAIR DOOR WIDTH PROVIDED IS 36"
• .3"/PERSON (7.3.3.2) ALLOWS 113 OCCUPANT LOAD AT STAIR, MAX.
PROTECTED AREAS:
• STORAGE ROOMS - REQUIRED VA FIRE PROTECTION DESIGN MANUAL 3.1.A AND PER NFPA 101:
39.3.2.1 AND 8.7 SMOKE PARTITIONS WITH SPRINKLER PROTECTION, PROVIDED.
LIFE SAFETY REQUIREMENTS
A
B C D E F G
426 SF
WAITING
006A
404 SF
OFFICE
001D
805 SF
CLASSROOM
004A
CORRIDOR
001-3
363 SF
BREAK
006B
812 SF
CLASSROOM
003B
857 SF
CLASSROOM
002B
1099 SF
OFFICE
TOILET (W)
TOILET (M)
STAIR
NORTH
C O
R R
ID
O
R
1-
C O
F F
E E
E L
E C
1B
OFFICE
ELEV
NORTH
ELEV
SOUTH
STAIR
SOUTH
806 SF
CLASSROOM
005A
806 SF
CLASSROOM
002A
800 SF
CLASSROOM
003A
806 SF
CLASSROOM
004B
840 SF
CLASSROOM
005B
575 SF
OFFICE
001A
S T
O R
1C
TRAVEL DISTANCE 292'- 11"TRAVEL DISTANCE 263'- 5"
AED
TRAVEL DISTANCE 132'- 4"
WAITING
001E
122 SF
TELECOM
008A
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
FV
20'-0"
FV
26'-0" FV
133'-0"
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
'-0
F V
6'
-0
OFFICE
008C
OFFICE
008C
OFFICE
020E
OFFICE
020D
OFFICE
020C
OFFICE
020B
OFFICE
020A
COMPUTER LAB
FISCAL SERVICE
DIRECTOR
CONFERENCE ROOM
008F
AFGE UNION OFFICE
011A
UNION OFFICE
BREAK
020G
VESTIBULE
020-61
MECHANICAL ROOM
CANTEEN STORAGE
009-61
ELECTRICAL
LOADING DOCK
CORRIDOR
CORR
CORRIDOR
CORRIDOR
IRM
SERVER ROOM
015B
RESTROOM
RESTROOM
ELEVATOR ROOM
HAC
STOR
015A
CORRIDOR
ELEV CONTROL
F E
C
FEC
FEC
F E
C
F E
C
FEC
FEC
FEC
FEC
F E
C
FEC
FEC
FEC
FEC
FEC
FEC
A
B C D E F G
816 SF
CLASSROOM
106A514 SF
CLASSROOM
798 SF
CLASSROOM
106B
802 SF
CLASSROOM
107A
797 SF
CLASSROOM
107B
879 SF
CLASSROOM
246 SF
CONFERENCE
104 374 SF
CORRIDOR
CORRIDOR
VFW
VETERAN'S OF AMERICA
PARALYZED OFFICE
KANSAS COMMISSION
VETERAN'S AFFAIRS
QUALITY ASSURANCE
TLT
TLT
VESTIBULE
TRAVEL DISTANCE = 137' 4"
T R
A V
E L
D
IS
T A
N C
E
9"
FV
26'-0"
FV
20'-0"
FV
20'-6"
FV
20'-6"
FV
20'-0"
FV
26'-0" FV
133'-0"
F V
'-0
F V
'-0
F V
'-0
'-0
'-0
'-0
'-0
'-0
'-0
F V
8'
-0
DISABLED AMERICAN
VETERAN'S
AM VETS
124B
MILITARY OF THE PURPLE
ORDER HEART
124A
SECRETARY
PATIENT CARE DIRECTOR
OF ASSOCIATE
123E
ASSOCIATE DIRECTOR'S
OFFICE
123D
DIRECTOR'S SUITE
126A
OFFICE IRM
123C
KITCHEN
126B
DIRECTOR'S OFFICE
126D
CONFERENCE DIRECTOR'S
ROOM
CONFERENCE DIRECTOR'S
ROOM
COMPUTER LAB
129A
COMMUNICATION
OFFICE
129B
ELEVATOR
1-ELEV-N
VETERAN'S SERVICE
PATIENT CARE DIRECTOR
OFFICE
123C
DIRECTOR'S SUITE
CHIEF OF STAFF
123A
OFFICE
MEN
WOMEN
HSK
DIABETES EDUCATION
NURSE
ELEVATOR
1-ELEV-S
STAIR
1-STAIR-S
MECHANICAL ROOM
PHYSICAL-PATIENT
ACCURE
OFFICE
111A
OFFICE
111B
OFFICE
111C
SOCIAL COACH
PHARMACY COUMADIN
CLINIC
PHARMACIST CLINICAL
115A
VOCATIONAL
REHABILITATION AND
EMPLOYMENT
STAIR
1-STAIR-N
126F
FEC
F E
C
FEC
BUILDING 61 KEY PLAN - GROUND FLOOR
PHASE 2
RENOVATED
TRAINING AND
OFFICE SPACE
N
PHASE 2
RENOVATED
OFFICE SPACE
OUT OF SCOPE
PHASE 1
RESTROOMS
BUILDING 61 KEY PLAN - FIRST FLOOR
PHASE 1
RENOVATED
TRAINING AND
OFFICE SPACE
NOUT OF SCOPE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
KS
KS
ARCH REG. NO.
ENGR REG. NO.
EXP. 12/31/2023
EXP. 12/31/2023
A-930, E-2586, CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
PLUMBING ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8650 ROBERT J. DOLE VA MEDICAL CENTER
SPUR #: 1794.08
SPUR #: 1794.08
/2
/2
:0 :5
A
M
B61 - LIFE SAFETY PLAN
JLJ 05 88JEH
ISSUED FOR CONSTRUCTION
ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM)
ADMINISTRATIVE SPACE
1/28/2022
589A7-21-702
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
GI012
N
3/32" = 1'-0"
BLDG 61 - GROUND LEVEL - LIFE SAFETY PLAN1
N
3/32" = 1'-0"
BLDG 61 - LEVEL 1 - LIFE SAFETY PLAN2
| 01_GI000_COVER SHEET |
| 02_GI001_GENERAL INFORMATION |
| 03_GI010_B61 -PHASING PLANS |
| 04_GI011_B61 -OCCUPANCY PLAN |
| 05_GI012_B61 -LIFE SAFETY PLAN |
File details come from the government source that posted it. Updated .