353-B003-MSR-64
MONTHLY STATUS REPORT
For
INTEGRATED MAINTENANCE, OPERATION & MODIFICATION SUPPORT (IMOMS)
Flight Training Devices
PERIOD COVERED:
01 – 31 July 2017
SECURITY CLASSIFICATION:
Unclassified
CONTRACT NO. HSCG38-12-C-410001
Data Item No. B003
Prepared For:
U.S. COAST GUARD
Aircraft Repair & Supply Center Elizabeth City, NC 27909-5001
Prepared By:
AERO SIMULATION, INC.
USCG ATC Mobile
8501 Tanner Williams Road Mobile, AL 33608
14 August 2017
1. Activities Summary Major contract activities that have occurred during the reporting period:
• Deficiency Reports (DRs) o Three new DRs were generated this reporting period.
o Aero Simulation, Inc. (ASI) has 19 DRs prepared for Joint Final
Inspection (JFI).
o ASI continued efforts on various other DRs.
o Additional information on specific DRs can be found in Appendix A.
• Engineering Change Proposal (ECP) o Two new ECPs were approved this reporting period.
o ASI has 14 ECPs prepared for JFI.
o ASI continued efforts on various other ECPs.
o Additional information on specific ECPs can be found in Appendix
B.
o Highlights and status of major ECPs are summarized below:
022-16, CASPER Crystal Server Power Switch / ARC 210 Data Port. ASI received data from the sensor branch about changes to the aircraft pallets. ASI generated, and received approval for an ECP to incorporate these changes on the device. Utilizing United States Coast Guard (USCG) provided Government Furnished Equipment (GFE), ASI installed the switch and port as requested. No documentation will be updated by this change. ASI will mark this as ready for JFI next reporting period.
021-16, MH-65 Single Data Bus Failure / Dual Data Bus Lockup Emergency Procedures (Eps). Proof of concept prototyping was performed and ASI has ordered 1553 bus relays in order to fail the 1553 data busses on the MH-65 Operational Flight Trainers (OFTs).
018-16, Coast Guard Aircrew Weapons Trainer (CG-AWT) Cabin lightning. ASI has prototyped the installation and is proceeding with the final installation efforts.
016-16, MH-60T Engine High Side Failure with loss of Np and Torque indications. ASI has completed Contractor Final Inspection (CFI) and is prepared to conduct JFI.
012-15, MH-65Dx Automatic Flight Control System (AFCS), Flight Director (FD) & Control Loader System (CLS) Integration and 001-16, MH-65D1 AFCS/FD System Problem Report (SPR) Clearance. ASI is making final Trainer Test Procedures and Results Report (TTPRR) updates and will mark this as ready for JFI next reporting period.
007-15, MH-60T Cockpit Procedure Trainer (CPT) Telestra Upgrade. Site engineers have implemented the host side changes associated with the “test to speech” Automatic Terminal Information Service (ATIS) functionality on the OFT, in a development environment. ASI is in the process of documenting the hardware changes made by this upgrade. ASI began and completed the integration and CFI phases on this effort on the CPT. Currently, ASI is in the integration and test phase on the OFT. Site engineers will conduct JFI on the CPT and OFT with the USCG when CFI is completed on the OFT.
003-15, HC-144B OFT Forward Looking Infrared (FLIR) Universal Hand Control Unit (UHCU). The UHCU is installed in the OFT and is functional. ASI is in the process of documenting the hardware changes made by this upgrade.
Installation of final minor hardware has been deferred until after the documentation has been completed, the system is fully operational as is.
026-14, Update the MH-60T CPT and OFT Embedded Global Positioning (EGI), Inertial Navigation System (INS) Model. ASI will conduct additional testing before declaring this item as ready for JFI.
014-14, HC-144A CPT Vibrations. Changes have been incorporated into the CPT Block Configuration Upgrade (BCU) software and hardware. ASI is in the process of documenting the hardware changes made by this upgrade.
ASI will attempt to schedule formal testing of this ECP once the documentation is complete.
013-14, HC-144B OFT BCU and 012-14, HC-144B RFTD
BCU.
• Currently, three DRs remain open. The three open DRs are written up against the Enhanced Ground Proximity Warning System (EGPWS), and the same issues are present on the aircraft. These items were written up as DRs for tracking purposes and cannot be addressed until the issues are corrected on the aircraft. As of the end of this reporting period, these same discrepancies are still present on the aircraft.
• A list of open HC-144B OFT BCU DRs is included in Appendix A for tracking purposes.
• Engineering Change Notice (ECN) o Six new ECNs were generated this reporting period.
o One ECN was completed and closed this reporting period.
o Additional information on specific ECNs can be found in Appendix
C.
• ASI requested and received approval to utilize CLIN 4010 hours in support of AIR 007-16 to evaluate the Auto Fidelity Test (AFT) system on the MH- 65Dx devices. ASI Tampa engineers have begun to run the load and AFTs in the Tampa office.
• ASI engineers have continued evaluating options to replace the executive and possibly the operating system on the MH-65Dx devices. This effort would also replace the existing Initial Conditions (IC) scheme on the devices as well. ASI will generate an ECP based on our evaluation to the USCG for consideration.
• ASI continues to monitor the MH-65D1 and MH-65D2 due to what is described by instructors as “aerodynamic lockups”, “pitch bumps” and “pitch sensitivity” issues. There were no occurrences of these issues this reporting period. ASI will continue to collect data and provide this information to the USCG.
• ASI had numerous discussion with USCG personnel with respect to upgrades to the HC-144 aircraft. ASI will generate ECPs for the B1U, Integrated Engine Display System (IEDS) and Minotaur related upgrades to the aircraft.
• ASI generated and submitted to the USCG for consideration ECPs for the MH-65D1 Motion Seat and the HC-144 training devices throttle quadrant replacement.
• ASI engineers and technicians continued to support the USCG, and other contractors, with their efforts on programs contracted to other companies.
• ASI has continued to purge the obsolete records, parts, and equipment from the Flight Training System (FTS) facility. The obsolete parts will be removed from the annual inventory utilization report.
A. Maintenance Status:
• Preventive MAFs:
o All required preventive maintenance actions for the reporting period were accomplished.
• Unscheduled MAFs:
o Detailed Maintenance Action Data initiated this reporting period is shown in Appendix D. Additional data can be found by logging into the IMOMS issue tracker. In addition to the detailed status in Appendix D, below is a graphical representation of overall and historical MAF status and new MAFs by device and status (reporting period).
Total MAFs by Status
New MAFs by Device
New MAFs by Status
B. DR Status:
Below is a graphical representation of overall DR status and DRs by device. Detailed DR status is shown in Appendix A.
DRs by Device
DRs by Status
C. ECP Status:
Detailed and historical ECP data is shown in Appendix B.
D. Action Item Requests (AIR) Status:
No new AIRs were generated this reporting period. Detailed status and historical AIR data is shown in Appendix E.
a) AIR 006-16: In work.
b) AIR 007-16: In work.
c) AIR 009-16: In work.
d) AIR 014-16: Complete.
e) AIR 023-16: Complete.
E. Contract Line Item Number (CLIN) 4006 Activities:
• None.
F. Contract Line Item Number (CLIN) 4010/4004 Activities:
• None.
G. Data Items:
The following submitted contract Data Item received no response and is considered accepted due to the concept of forbearance under contract law. Additional Data Item information is shown in Appendix I.
a) B003 Monthly Status Report (MSR) #61, submitted 11 May 2017;
response due 11 June 2017.
2. Action Items None.
3. Inventory Summary The Inventory Summary is shown in Appendix F.
4. Problem Areas Affecting Technical or Scheduling Elements, with Background and Any Recommendations for Solutions Beyond the Scope of the Contract
5. Problem Areas Affecting Cost Elements, with Background and Any Recommendations for Solutions Beyond the Scope of the Contract
6. Trainer Performance Summary A. The Trainer Performance Summary (Device Utilization) for the reporting period is shown in Appendix G.
a) Aircrew Weapons Trainer (AWT):
1) There was no Chargeable Downtime (CDT) or Partial Mission Capability Quantity (PMCQ) during the reporting period.
b) HC-144 OFT:
1) There was 1.5 hours of CDT during the reporting period. The
CDT was due to loss of IPs Intercommunications System (ICS) and Image Generator (IG) issues. The ICS was restored by cycling the ACU2. The IG issues were resolved by multiple IG restarts/re-images.
2) There was a PMCQ of 0.1 for this reporting period. The PMCQ was primarily attributed to problems with the IPs ICS (see above) and motion. The issue with the motion may have been operator error, as no problems were found.
c) HC-144 CPT:
1) There was no CDT or PMCQ during the reporting period.
d) MH-60T OFT:
1) There was no CDT during the reporting period.
2) There was a PMCQ of 0.32 for this reporting period. The
PMCQ was primarily attributed to problems with the visual display system being distorted, issues with the radar system test display and the motion dropping offline. The display distortion was corrected by reloading an archived projector alignment. The radar system was restarted. The motion system was manually settled and re-engaged without issue.
e) MH-60T CPT:
1) There was no CDT or PMCQ during the reporting period.
f) MH-65D1:
1) There was no CDT during the reporting period.
2) There was a PMCQ of 5.4 for this reporting period. The PMCQ was primarily attributed to failure and/or sticking of miscellaneous switches, lights and hardware, Instructor ICS issues and problems with the modeling of the 'Gyro Reversionary Operation’ associated with the AFCS and EGIs systems. Miscellaneous hardware/bulbs were cleaned, repaired or replaced. The headset cable was replaced or repaired. The AFCS/EGI issue is in work.
g) MH-65D2:
1) There was no CDT during the reporting period.
2) There was a PMCQ of 3.25 for this reporting period. The
PMCQ was primarily attributed to failure and/or sticking of miscellaneous switches, flashlights and hardware, the HF showed 'NO-GO' and issues with the VEMD. Miscellaneous hardware/flashlight batteries were cleaned, repaired or replaced. The HF radio just started working on its own, without host restart. The issues with the VEMD are in work.
h) Reconfigurable CPT (RCPT):
1) There was no CDT or PMCQ during the reporting period.
7. Trips and Significant Results
8. Record of All Significant Correspondence and Commitments A summary of correspondence that took place between ASI and the Government concerning the IMOMS program during this period is contained in Appendix H.
However, if there are any comments that are not as the Government recalls or any comments missing that the Government feels are significant, please contact the ASI Program Manager (PM) (section 12.0).
9. Engineering Change Proposal (ECP) Detailed and historical ECP data is shown in Appendix B.
10. Contract Status Contract Data Requirements List (CDRLs) that have been submitted during the past month and those that have been accepted, rejected, forborne, or closed are shown in BOLD text in Appendix I.
11. Planned Activities During the Following Reporting Period The following is a list of major contract activities that are planned for the upcoming reporting period:
A. Continue and complete efforts on various AIRs, ECNs, ECPs, and DRs.
B. Continue to identify and generate ECNs, ECPs and DRs.
C. Continue working with the USCG to schedule JFI/closure of DRs and ECPs.
D. Continue to support the USCG with efforts of other contractors.
E. Perform all applicable Preventive MAFs.
F. Work off unscheduled MAFs as required.
G. The following Data Item is overdue and will be considered accepted at the end of the next reporting period if no response is received due to the concept of forbearance under contract law.
a) B003 Monthly Status Report (MSR) #62, submitted 14 June 2017;
response due 14 July 2017.
12. Name and Telephone Number of Preparer(s) of the Report
Robert Rodriguez 813-498-1187
13. Appendices for any Necessary Tables, References, Photographs, Illustrations, and Charts.
A. DR Summary B. ECP Summary C. ECN Summary D. Corrective Maintenance Action Summary E. AIR Summary F. Inventory Summary G. Trainer Performance Summary H. Correspondence Summary I. CDRL Status
Appendix A
DR Summary
DR Summary – July 2017
AWT MH65D1 MH65D2
MH60T
CPT
MH60T
OFT CASPER
HC144
OFT
HC144
CPT RCPT Off Eq Totals
New DRs 0 1 0 2 0 0 0 0 0 0 3
CFI 0 0 0 0 0 0 0 0 0 0 0
GFI 0 1 0 0 0 0 0 0 0 0 1
Closed 0 0 0 0 0 0 0 0 0 0 0 CF DRs 0 10 0 3 8 0 2 0 3 0 26
CFI 0 0 0 0 0 0 1 0 0 0 1
GFI 0 9 0 3 5 0 1 0 0 0 18
Closed 0 0 0 0 0 0 0 0 0 0 0 Open 0 11 0 5 8 0 2 0 3 0 29
New DR Status – July 2017
Device Key DR# Summary Description Status Created Updated
MH-60T
CPT
J305-
60CPT17003 No ELT tones could be heard on any radio
P/CP could hear ELT tones when enabled and tuned. Open 12-Jul-17 12-Jul-17
MH-60T
CPT
J305-
60CPT17002 ATIS message has Scattered and Overcast cloud types reversed
ATIS message has Scattered and Overcast cloud types reversed.
Open 12-Jul-17 12-Jul-17
MH-65D
OFT
J305-
65DOFT17012 No ATIS for Vandenberg and Santa Barbara Muni Airports
There are no ATIS transmission for Vandenberg and Santa Barbara Muni Airports.
Ready For Customer Recheck
11-Jul-17 14-Jul-17 https://10.0.1.102:8444/browse/J305-9510 https://10.0.1.102:8444/browse/J305-9510 https://10.0.1.102:8444/browse/J305-9501 https://10.0.1.102:8444/browse/J305-9501 https://10.0.1.102:8444/browse/J305-9496 https://10.0.1.102:8444/browse/J305-9496
CF DR Status – July 2017
Device Key DR# Summary Description Status Created Updated
HC-144
OFT
J305-
144OFT17002 CDU: "Check DB Date" CDU shows "CHK DB DATE" even when FMS database is current.
Ready For Customer Recheck
25-Apr-17 29-Apr-17
HC-144
OFT
J305-
144OFT17001 Autopilot and Flight Director Issues
1. When flying FMS approaches to a course, APPR mode captures immediately after selection. Should fly in HDG SEL mode, until FMS course capture.
2. VNAV captures too high, and aircraft does not follow VNAV flight plan.
3. ILS approaches: Aircraft overcorrects and is unable to maintain localizer course when flying faster than (140kts
GS).
Ready For Internal Recheck
25-Apr-17 31-Jul-17
HH-65C
RCPT
J305-
65RCPT15001 CDU ECMS Page Engine parameters displays (N1, N2, TOT, Q) on CDU ECMS page show a value when respective indicating system is failed. Should display "---".
In Progress 27-Feb-15 31-Aug-15
HH-65C
RCPT
J305-
65RCPT14002 EGI Failures, power off, etc.
MFD Heading fail "flags" are not representative of the aircraft with EGIs off or failed. Single EGI failures appear correct, but dual failures drop flags completely.
Written up as MAF J305-4206. MAF closed due opening of DR.
In Progress 24-Jun-14 6-Dec-16
HH-65C
RCPT
J305-
65RCPT13006 IFF MON light IFF MON light should not illuminate in STANDBY mode. In Progress 21-Nov-13 6-Dec-16
MH-60T
CPT
J305-
60CPT17001 P/CP ESIS Buttons Pilot and Copilot ESIS Buttons inop. They work once after each Host reset, then stop responding.
Ready For Customer Recheck
25-Jan-17 12-Feb-17
MH-60T
CPT
J305-
60CPT16002 Lower Cloud Level Airfield elevation gets stuck in the system which prevents proper cloud deck adjustments. Day 2 initial setting begin @ KRIV elevation 1500' we fly to KLGB which is @ sea level. Even after changing airport control to KLGB (or any airport) the airport elevation on the environmental fog /data/wind page stays @1500'. If the aircraft is repositioned to another airport via the airport page the elevation finally changes.
Ready For Customer Recheck
4-Nov-16 21-Nov-16 https://10.0.1.102:8444/browse/J305-9154 https://10.0.1.102:8444/browse/J305-9154 https://10.0.1.102:8444/browse/J305-9153 https://10.0.1.102:8444/browse/J305-9153 https://10.0.1.102:8444/browse/J305-5466 https://10.0.1.102:8444/browse/J305-5466 https://10.0.1.102:8444/browse/J305-4261 https://10.0.1.102:8444/browse/J305-4261 https://10.0.1.102:8444/browse/J305-3220 https://10.0.1.102:8444/browse/J305-3220 https://10.0.1.102:8444/browse/J305-8687 https://10.0.1.102:8444/browse/J305-8687 https://10.0.1.102:8444/browse/J305-8361 https://10.0.1.102:8444/browse/J305-8361
Device Key DR# Summary Description Status Created Updated
MH-60T
CPT
J305-
60CPT16001 Approach Plate Disappears
The moving map spontaneously changes off of the approach plate selected to another, resulting in a blank map screen.
Ready For Customer Recheck
4-Nov-16 21-Nov-16
MH-60T
OFT
J305-
60OFT16002 FLIR, Display, IOS and Host PC cabinet/system documentation
Relocation of the display PC and FLIR system components into the new cabinet was never fully documented.
In Progress 13-Jul-16 13-Apr-17
MH-60T
OFT
J305-
60OFT17004 Pilots could not hear
121.5 audio tone for ELT with DF tuned to 121.5 and LPCAP pin 7 pushed in
Pilots could not hear 121.5 audio tone for ELT with DF tuned to 121.5 and LPCAP pin 7 pushed in.
Open 5-May-17 5-May-17
MH-60T
OFT
J305-
60OFT17003 When "ATC chatter" selected on Comms page, IP cannot hear chatter at IP station
When "ATC chatter" selected on Comms page, IP cannot hear chatter at IP station.
Open 5-May-17 5-May-17
MH-60T
OFT
J305-
60OFT17002 CADS: Recorded events in Alaska
Recorded flight in Alaska during the daytime, showed on debrief as nighttime.
Ready For Customer Recheck
25-Apr-17 20-Jun-17
MH-60T
OFT
J305-
60OFT17001 WxR Coldstart Provide WxR computer coldstart. Ready For Customer Recheck
16-Jan-17 5-Apr-17
MH-60T
OFT
J305-
60OFT16005 DVD Burning at CADS Debrief Station
Can not burn DVD at debrief station. Ready For Customer Recheck
13-Dec-16 5-Jan-17
MH-60T
OFT
J305-
60OFT16004 Lower Cloud Level Airfield elevation gets stuck in the system which prevents proper cloud deck adjustments. Day 2 initial setting begin @ KRIV elevation 1500' we fly to KLGB which is @ sea level. Even after changing airport control to KLGB (or any airport) the airport elevation on the environmental fog /data/wind page stays @1500'. If the aircraft is repositioned to another airport via the airport page the elevation finally changes.
Ready For Customer Recheck
4-Nov-16 21-Nov-16
MH-60T
OFT
J305-
60OFT16003 Approach Plate Disappears
The moving map spontaneously changes off of the approach plate selected to another, resulting in a blank map screen.
Ready For Customer Recheck
4-Nov-16 21-Nov-16
MH-65D
OFT
J305-
65DOFT17008 Network Switch Network Switch (3A2A6) failed, has been replaced with compatible switch.
Open 5-May-17 26-May-17 https://10.0.1.102:8444/browse/J305-8359 https://10.0.1.102:8444/browse/J305-8359 https://10.0.1.102:8444/browse/J305-7782 https://10.0.1.102:8444/browse/J305-7782 https://10.0.1.102:8444/browse/J305-9215 https://10.0.1.102:8444/browse/J305-9215 https://10.0.1.102:8444/browse/J305-9214 https://10.0.1.102:8444/browse/J305-9214 https://10.0.1.102:8444/browse/J305-9155 https://10.0.1.102:8444/browse/J305-9155 https://10.0.1.102:8444/browse/J305-8633 https://10.0.1.102:8444/browse/J305-8633 https://10.0.1.102:8444/browse/J305-8512 https://10.0.1.102:8444/browse/J305-8512 https://10.0.1.102:8444/browse/J305-8360 https://10.0.1.102:8444/browse/J305-8360 https://10.0.1.102:8444/browse/J305-8358 https://10.0.1.102:8444/browse/J305-8358 https://10.0.1.102:8444/browse/J305-9213 https://10.0.1.102:8444/browse/J305-9213
Device Key DR# Summary Description Status Created Updated
MH-65D
OFT
J305-
65DOFT17011 Vandenburg TACAN
(VBG)
No bearing received on Vandenberg TACAN (VBG) Chan 59Y.
Ready For Customer Recheck
29-Jun-17 14-Jul-17
MH-65D
OFT
J305-
65DOFT17010 Engine Compartment Fire EPs
EP 201 L/R (Engine Compartment Fire) and EP 202 L/R (Engine Compartment Fire (Extinguished w/ 1 Bottle):
Respective FIRE lights do not extinguish when extinguishers are used.
Ready For Customer Recheck
23-Jun-17 12-Jul-17
MH-65D
OFT
J305-
65DOFT17009 Vandenburg (KVBG) ILS
RWY 12
Vandenburg (KVBG) ILS RWY 12 inop. Constant GS flag in view.
Ready For Customer Recheck
6-Jun-17 6-Jun-17
MH-65D
OFT
J305-
65DOFT17007 Trainer I/O not working No lights, indicators in cockpit. IOS Freeze/Run and Motion Disable lights continually blinking. Host load blowing up, scrolling NaNs.
Ready For Customer Recheck
3-Apr-17 4-May-17
MH-65D
OFT
J305-
65DOFT17006 When Copilot is in hot mic, navaids are over ridden
With the Pilot or Copilot on Hot Mic they should still hear navaid tones and Comms.
Ready For Customer Recheck
23-Mar-17 20-Jun-17
MH-65D
OFT
J305-
65DOFT17005 When ATC chatter is ON, IOS station should override it when IP transmits, this is not the case
When ATC Chatter is on and the Instructor keys his mic he should override chatter side tone in his headset while transmitting.
Ready For Customer Recheck
23-Mar-17 29-Jun-17
MH-65D
OFT
J305-
65DOFT17004 When observer selected at IOS both the pilot and copilot can still hear. IP on ICS
Several problems related to the logic with the ICS and Comms system.
Ready For Customer Recheck
23-Mar-17 20-Jun-17
MH-65D
OFT
J305-
65DOFT17003 IOS cannot hear ATIS tuned into FM with FM selected
With the FM radio tuned to an ATIS frequency the ATIS transmission cannot be heard at the Instructor station.
Ready For Customer Recheck
23-Mar-17 20-Jun-17
MH-65D
OFT
J305-
65DOFT17002 No Audio for VOR ident at VNY (Van Nuys)
VOR-DME ident could be heard from the point the station was acquired up to 40 miles out. Inside of 40 miles the ident could no longer be heard.
Ready For Customer Recheck
23-Mar-17 20-Jun-17 https://10.0.1.102:8444/browse/J305-9468 https://10.0.1.102:8444/browse/J305-9468 https://10.0.1.102:8444/browse/J305-9446 https://10.0.1.102:8444/browse/J305-9446 https://10.0.1.102:8444/browse/J305-9352 https://10.0.1.102:8444/browse/J305-9352 https://10.0.1.102:8444/browse/J305-9037 https://10.0.1.102:8444/browse/J305-9037 https://10.0.1.102:8444/browse/J305-9005 https://10.0.1.102:8444/browse/J305-9005 https://10.0.1.102:8444/browse/J305-9003 https://10.0.1.102:8444/browse/J305-9003 https://10.0.1.102:8444/browse/J305-9001 https://10.0.1.102:8444/browse/J305-9001 https://10.0.1.102:8444/browse/J305-9000 https://10.0.1.102:8444/browse/J305-9000 https://10.0.1.102:8444/browse/J305-8999 https://10.0.1.102:8444/browse/J305-8999
HC-144B OFT BCU (ECP 013-14) DR Status
DR # Key Summary Description Status Created Document Section
Discovery Phase
HC144B-1-
GFI-112
J724-
EGPWS TAC Mode Inop in Aircraft
EGPWS TAC mode is still not operational in the aircraft. Update TTPRR and correct RFTD software when operational and verified in the OFT.
Open 18-Nov-15 EGPWS TAC Mode
7.6.2 Step 95
GFI
HC144B-1-
GFI-08
J724-
No Terrain Clearance Floor Alert
This does not currently work on aircraft, awaiting EGPWS software update.
Did not get "Too Low, Terrain" alert.
Open 18-Nov-15 EGPWS 7.6.2 Step
GFI
HC144B-1-
GFI-07
J724-
Unsafe Terrain Clearance, No Flap Warning
This does not currently work on aircraft, awaiting EGPWS software update.
When performing the Mode 4A Unsafe Terrain Clearance Gear and Flap Warnings test, got the "Too Low Gear" alert, but not the "Too Low Flaps" alert.
Open 17-Nov-15 EGPWS 7.6.2 Step
GFI
https://svn.aerosimulation.com/jira/browse/J724-247 https://svn.aerosimulation.com/jira/browse/J724-247 https://svn.aerosimulation.com/jira/browse/J724-243 https://svn.aerosimulation.com/jira/browse/J724-243 https://svn.aerosimulation.com/jira/browse/J724-242 https://svn.aerosimulation.com/jira/browse/J724-242
Appendix B
ECP Summary
ECPs Open or Closed this Reporting Period
ECP# Device Key Summary Description Status Created Updated
ECP
022-16 (E)
Casper J305-
Crystal Server Power Switch / ARC 210 Data Port
Current functionality: Crystal Server Power Switch / ARC 210 Data Port not installed.
Desired functionality: Install Crystal Server Power Switch / ARC 210 Data Port. No functionality is required, for student familiarization only.
In Progress 5-Jul-17 11-Jul-17
ECP
021-16 (E)
MH-65D
OFT
J305-
Single Data Bus Failure / Dual Data Bus Lockup EPs
Current functionality: Data Bus EPs are not simulated.
Desired functionality: The ability to demonstrate Data Bus Failures and Dual Data Bus Lockup by disconnecting CDUs from either (or both) of their data busses.
NOTE: This ECP also applies to the MH-65D2 OFT also.
Open 5-Jul-17 13-Jul-17
ECP
020-16 (E)
MH-60T
OFT
J305-
Computer Aided Debrief System (CADS) Burn to DVD function
Current functionality: Burn to DVD function will fail for events greater than approximately 2.5 hrs in length. Captured data exceeds the storage capacity of a DVD.
Desired functionality: Ability to export event data to removable media (flash drive, portable hard drive).
NOTE: This ECP also applies to the MH-65D1 & MH-65D2 devices.
Ready For Customer Recheck
2-Mar-17 29-Mar-17
ECP
019-16 (E)
Casper J305-
MX-20 Turret System Built-In-Test (BIT)
Current functionality: MX-20 Turret System BIT not simulated.
Desired functionality: Model the MX-20 Turret System to perform BIT when initiated by the operator.
Ready For Customer Recheck
2-Mar-17 29-Mar-17
ECP
018-16 (E)
AWT J305-
Capsule Lighting Current functionality: The CG-AWT Cabin lightning is insufficient for students to perform training tasks and replicate the selected time of day. The existing lighting does not adequately illuminate the cabin to safely perform required maintenance functions.
Desired functionality: Install a dimmable overhead LED lighting system in the cabin overhead to control cabin ambient lighting that coincides with time of day conditions and provides adequate lighting to perform training tasks. Upgrade the existing capsule lighting system to more adequately illuminate capsule maintenance work areas.
In Progress 2-Mar-17 14-Jul-17 https://10.0.1.102:8444/browse/J305-9476 https://10.0.1.102:8444/browse/J305-9476 https://10.0.1.102:8444/browse/J305-9477 https://10.0.1.102:8444/browse/J305-9477 https://10.0.1.102:8444/browse/J305-8898 https://10.0.1.102:8444/browse/J305-8898 https://10.0.1.102:8444/browse/J305-8897 https://10.0.1.102:8444/browse/J305-8897 https://10.0.1.102:8444/browse/J305-8896 https://10.0.1.102:8444/browse/J305-8896
ECP# Device Key Summary Description Status Created Updated
ECP
017-16 (E)
MH-65D
OFT
J305-
IOS NAVAID Ident Selection
Current functionality: NAVAID Idents can only be selected on or off as a group. There is no functionality to allow the Instructor Pilot to select which NAVAID he is monitoring.
Desired functionality: The ability to individually select/de-select the NAVAIDS to monitor at the instructor station.
NOTE: This ECP applies to the MH-65D2 OFT also.
Ready For Customer Recheck
1-Mar-17 12-Jun-17
ECP
016-16
MH-60T
OFT
J305-
Engine High Side Failure with loss of Np and Torque Indications
Current functionality: Symptoms of Engine High Side Failure EPs do not include loss of respective Np and Torque indications.
Desired functionality: Model new Engine High Side Failure EPs that provide the symptoms of the current Engine High Side Failure EPs, but also include the loss of respective Np and Torque indications.
NOTE: This ECP also applies to the MH-60T CPT.
Ready For Customer Recheck
2-Dec-16 27-Apr-17
ECP
014-16
MH-65D
OFT
J305-
IP & OBS ICS/COMMs Cords
Current functionality: The current IP & OBS cord connectors are not mounted, but are hanging freely on the cord that enters the IOS & OBS stations. These cords are not currently removable/swappable.
Desired functionality: To have the ICS/COMMs cord connector mounted at the IOS/OBS stations.
Reason for the change: To be able to remove and replace the cord between head set and Trainer connector.
Impact on training, if denied: When failure occurs, the Trainer is down during the repair of the cord/connection, because it is not swappable.
In Progress 19-Oct-16 5-May-17
ECP
013-16
MH-60T
CPT
J305-
IOS Book Shelf Current functionality: No designated area to place ‘Trainer Book’ or A/C pubs.
Desired functionality: To have a book shelf/hutch over the IP/IOS station to place Trainer book and various pubs.
Reason for the change: To prevent these books/pubs from being scattered around the IOS, cockpit and surrounding areas.
NOTE: We will not be updating any drawing for this.
Ready For Customer Recheck
19-Oct-16 22-Nov-16 https://10.0.1.102:8444/browse/J305-8887 https://10.0.1.102:8444/browse/J305-8887 https://10.0.1.102:8444/browse/J305-8469 https://10.0.1.102:8444/browse/J305-8469 https://10.0.1.102:8444/browse/J305-8268 https://10.0.1.102:8444/browse/J305-8268 https://10.0.1.102:8444/browse/J305-8267 https://10.0.1.102:8444/browse/J305-8267
ECP# Device Key Summary Description Status Created Updated
ECP
012-16
HU-25
OFT
J305-
Removal of the HU-25
OFT
1. Destructive disassembly of the device and associated components.
a. Majority of the effort will be done utilizing on-site employees under the normal IMOMS efforts (CLIN 4001).
b. Rental of equipment required for disassembly and transport to staging area.
c. Relocation of palletized components to USCG identified staging area.
d. Threaded studs for lower knuckles will be cut off at floor level.
e. High bay trenches and computer room subfloor shall be swept and or vacuumed.
2. USCG to remove existing cockpit air conditioner air handler.
3. Purge TDSP of all HU-25 documentation, unique spare parts, etc.
4. USCG to take lead on documentation required for turn in.
a. Assist USCG in the documentation of parts, etc., as required, for turn in.
In Progress 23-Sep-16 23-Sep-16
ECP
011-16
HC-144
OFT
J305-
HC-144B Main Battery Sealed Lead Acid Batteries (Slab)
Modify the host simulation to support the new Sealed Lead Acid Batteries.
Applicable to OFT and CPT.
Ready For Customer Recheck
25-Aug-16 6-Jun-17
ECP
010-16
HC-144
OFT
J305-
Custom IC Sets Current functionality: There are no custom or temporary slots available for saving IC Sets.
Desired functionality: Provide 30 slots per gaming area for IP custom and/or temporary use. Change “save ic” password to prevent saving over existing ic sets. Use existing “save ic” password for the IP custom ic sets.
NOTE: This ECP also applies to the HC-144 RFTD.
Ready For Customer Recheck
24-Aug-16 12-Oct-16
ECP
009-16
MH-60T
OFT
J305-
Instructor Operator Station (IOS) Emergency Procedures (EP) Descriptions
Current functionality: IOS EP descriptions are based on Emergency Operating Procedures listed in CGTO 1H-60T-1.
Desired functionality: Update IOS EP descriptions as listed in CGTO
1H-60T-RNP-1.
NOTE: This ECP also applies to the MH-60T CPT.
Ready For Customer Recheck
24-Aug-16 21-Nov-16 https://10.0.1.102:8444/browse/J305-8161 https://10.0.1.102:8444/browse/J305-8161 https://10.0.1.102:8444/browse/J305-8023 https://10.0.1.102:8444/browse/J305-8023 https://10.0.1.102:8444/browse/J305-8012 https://10.0.1.102:8444/browse/J305-8012 https://10.0.1.102:8444/browse/J305-8011 https://10.0.1.102:8444/browse/J305-8011
ECP# Device Key Summary Description Status Created Updated
ECP
005-16
MH-60T
OFT
J305-
Arrival and Departure charts at Instructor Operator Station (IOS)
Current functionality: Unable to view Standard Terminal Arrival Route (STAR) and Standard Instrument Departure (SID) charts at the Instructor Operator Station (IOS).
Desired functionality: Add the capability to view STAR and SID charts at the IOS.
NOTE: This ECP also applies to MH-65D1, MH-65D2, MH-60T CPT, and RCPT(MH-65D).
Ready For Customer Recheck
2-Aug-16 5-Apr-17
ECP
006-16
AWT J305-
OBIOS Monitors Current functionality: OBIOS monitors are non-NVG compatible. IG Stealth View is not viewable at OBIOS.
Desired functionality: OBIOS monitors that are NVG compatible. Ability to switch left OBIOS monitor between Map View and IG Stealth View.
In Progress 2-Aug-16 4-May-17
ECP
001-16
MH-65D
OFT
J305-
MH65D1 AFCS/FD SPR
Clearance
As a follow on to ECP 012-15 (Automatic Flight Control System (AFCS), Flight Director (FD) & Control Loader System (CLS) Integration), this ECP addresses SPRs as a result of the ECP 012-15 efforts.
In Progress 30-Jun-16 11-Jul-16
ECP
011-15
MH-60T
OFT
J305-
60OFT KVM upgrade Install Avocent 2015 KVM. In Progress 31-Mar-16 9-Feb-17
ECP
012-15
MH-65D
OFT
J305-
Automatic Flight Control System (AFCS), Flight Director (FD) & Control Loader System (CLS) Integration
Current functionality: The MOOG/FCS flight control loader drives the yaw axis input. The MH-65D2 OFT uses legacy AFCS/FD software models.
Desired functionality: AFCS model drives the yaw channel through commands to the control loader on both the MH-65D-1 and MH-65D-2 operational flight trainers. Integrate the MH-65D1 OFT AFCS and FD models onto the MH-65D2 OFT.
NOTE: This ECP applies to both the MH-65D1 OFT and MH-65D2
OFT.
Ready For Internal Recheck
1-Mar-16 12-Jun-17
ECP
010-15
MH-65D
OFT
J305-
Balance power between phases
Current functionality: Power (Current utilization) is unusually high on some legs than others causing UPS to go into bypass.
Desired functionality: Balance power to more acceptable level so UPS will not go into bypass.
In Progress 19-Feb-16 25-May-16 https://10.0.1.102:8444/browse/J305-7896 https://10.0.1.102:8444/browse/J305-7896 https://10.0.1.102:8444/browse/J305-7895 https://10.0.1.102:8444/browse/J305-7895 https://10.0.1.102:8444/browse/J305-7732 https://10.0.1.102:8444/browse/J305-7732 https://10.0.1.102:8444/browse/J305-7264 https://10.0.1.102:8444/browse/J305-7264 https://10.0.1.102:8444/browse/J305-7106 https://10.0.1.102:8444/browse/J305-7106 https://10.0.1.102:8444/browse/J305-7043 https://10.0.1.102:8444/browse/J305-7043
ECP# Device Key Summary Description Status Created Updated
ECP
009-15
HC-144
OFT
J305-
Daisy Chain KVMs Current functionality: User has to "jump" to a second set of KVMs when control of Aechelon computers is required.
Desired Functionality: To see all the available computers on a single dialog display.
In Progress 19-Feb-16 25-Aug-16
ECP
007-15
MH-60T
CPT
J305-
MH-60T CPT Telestra upgrade
Current functionality: The existing aural cues/communication system on the OFT is an ASTi DACS. Unsupportable.
Desired functionality: Technical Refresh. Replace DACS with Telestra.
In Progress 22-Jan-16 27-Jul-17
ECP
006-15
MH-60T
CPT
J305-
Projector control at IOS Current functionality: Projector control is by a remote control.
Desired functionality: Provide projector control at the IOS.
Ready For Customer Recheck
22-Jan-16 29-Mar-17
ECP
003-15
HC-144
OFT
J305-
Forward Looking Infrared (FLIR) Universal Hand Control Unit (UHCU)
Current functionality: The HC-144 OFT currently utilizes the FLIR HCU Box-on-a-stick type controller.
Desired functionality: Install the new version FLIR UHCU.
In Progress 14-Oct-15 9-May-17
ECP
002-15
Casper J305-
CASPER Refresh Current functionality: Crystal Server not currently installed.
Desired functionality: Install Crystal Server. Perform the intent of CASPER_ATW_TCTO_Final_Draft_052915 on the CASPER Trainer.
Install Crystal Server and associated hardware into trainer; stimulate Crystal Server with video from simulated sensors, and GPS position of simulated ownship.
Ready For Customer Recheck
31-Aug-15 23-May-16
ECP
025-14
HC-144
OFT
J305-
Visual Model Effects/Animations
Current functionality: The HC-144A OFT and CPT do not chain most of the effects and animations to the models, but instead they are currently independent models.
Desired functionality: Chain effect and animations to the existing virtual models.
NOTE: This ECP also applies to the HC-144 RFTD.
Ready For Customer Recheck
25-Feb-15 21-Nov-16 https://10.0.1.102:8444/browse/J305-7042 https://10.0.1.102:8444/browse/J305-7042 https://10.0.1.102:8444/browse/J305-6904 https://10.0.1.102:8444/browse/J305-6904 https://10.0.1.102:8444/browse/J305-6903 https://10.0.1.102:8444/browse/J305-6903 https://10.0.1.102:8444/browse/J305-6519 https://10.0.1.102:8444/browse/J305-6519 https://10.0.1.102:8444/browse/J305-6337 https://10.0.1.102:8444/browse/J305-6337 https://10.0.1.102:8444/browse/J305-5442 https://10.0.1.102:8444/browse/J305-5442
ECP# Device Key Summary Description Status Created Updated
ECP
026-14
MH-60T
OFT
J305-
Update EGI Model Current functionality: The existing EGI model is sufficient for pre-RNP CAAS testing requirements but not for the aircraft RNP CAAS hardware and software recently installed on the MH-60T CPT.
Desired functionality: Insert the existing Government-owned HC144 OFT EGI model into the MH-60T CPT & OFT to fully utilize the new RNP CAAS platform for testing and training.
NOTE: This ECP applies to the MH-60T CPT also.
In Progress 12-Feb-15 27-Apr-17
ECP
018-14
MH-60T
OFT
J305-
MH-60T Transmission EPs
Modify device to reflect the changes in Transmission EPs based upon CGTO 1H-60T-1-CL1 Revision 1 - dated 8 April 2013. This ECP applies to MH-60T CPT as well.
Ready For Internal Recheck
5-Nov-14 24-Nov-14
ECP
015-14
MH-60T
OFT
J305-
MH-60T EDECU Incorporate new EDECU model that provides the same functionality, performance and limitations as the aircraft EDECU.
Ready For Internal Recheck
10-Oct-14 12-Aug-15
ECP
014-14
HC-144
CPT
J305-
Vibration Seat vibrations in RFTD. In Progress 10-Oct-14 18-Aug-16
ECP
013-14
HC-144
OFT
J305-
HC-144A OFT Baseline Configuration Upgrade
Convert the HC-144A OFT device to the HC-144A Ocean Sentry Refresh (OSR) baseline configuration.
Ready For Customer Recheck
1-Oct-14 11-Feb-16
ECP
009-14
MH-65D
OFT
J305-
ILS audio IDENTs Current functionality: The current ILS modeling allows you to identify ILS approaches via audio while 16 miles left or right of the inbound course. The current simulation is based on distance from transmitter and needs to be revised to a specific area in accordance with the AIM.
Desired functionality: ILS audio should only be available when within the bounded area that is given within the AIM for Localizer transmitters.
Revise TTPRR to demonstrate this functionality.
NOTE: This ECP also applies to the MH60TOFT, MH60TCPT, MH65COFT, and RCPT65.
In Progress 29-May-14 14-Nov-16 https://10.0.1.102:8444/browse/J305-5407 https://10.0.1.102:8444/browse/J305-5407 https://10.0.1.102:8444/browse/J305-4979 https://10.0.1.102:8444/browse/J305-4979 https://10.0.1.102:8444/browse/J305-4814 https://10.0.1.102:8444/browse/J305-4814 https://10.0.1.102:8444/browse/J305-4813 https://10.0.1.102:8444/browse/J305-4813 https://10.0.1.102:8444/browse/J305-4760 https://10.0.1.102:8444/browse/J305-4760 https://10.0.1.102:8444/browse/J305-4130 https://10.0.1.102:8444/browse/J305-4130
ECP# Device Key Summary Description Status Created Updated
ECP
031-13
MH-60T
CPT
J305-
MH-60T Visual Display System Upgrade
Current functionality: The current visual display system utilizes low resolution projectors.
Desired functionality: High resolution projectors, to take advantage of the new Aechelon IG capability.
Reason for the change: Improved training capabilities.
Impact on training, if denied: Reduced realism and situational awareness.
In Progress 8-Aug-13 25-May-16
ECP
022-13
HH-65C
OFT
J305-
VDS and IOS Update the IOS hardware design to improve desktop work area.
Update obsolete trainer power supplies.
Update current visual display system to improve NVG focus and minimize distracting cross-cockpit FOV artifacts.
Ready For Internal Recheck
19-Jul-13 23-Sep-16
ECP
024-13
MH-60T
OFT
J305-
#1 Generator Failure and #2 Generator Failure
NOTE: This ECP applies to the MH-60T OFT & the MH-60T CPT.
Current functionality: During main generator failure, #1 or #2 GEN caution is displayed.
Desired functionality: Add a second #1 Generator Failure (SLOW SWITCH) and include the following symptoms: #1 GEN Caution, SAS 1 and AUTOPILOT disengaged, AFCS Degraded, SAS 2 Fail Advisory, Stabilator Caution. Also include momentary loss of #1 MFD, DCS2, V1, ICU, and ADC1. The momentary loss should appear as these items losing power for 2-3 seconds, but then coming back on line as the #2 generator picks up the #1 AC Primary and AC Essential busses.
Add a second #2 Generator Failure (SLOW SWITCH) and include the following symptoms: #2 GEN Caution. Also include momentary loss of #2 CONV, and #2 and #5 MFDs. Again, this should be a 2-3 second power loss, with the equipment coming back on line as the #1 Generator picks up the #2 AC Primary Bus and #2 DC Primary Bus.
In Progress 10-Jun-13 30-Nov-14
ECP
016-13
MH-60T
CPT
J305-
MH-60T CPT Cockpit concurrence
Install new and or modify panels, CB labels, etc., to match the current aircraft configuration. Tie DTU-7100 into the simulation and complete the installation.
In Progress 29-Apr-13 22-Nov-16 https://10.0.1.102:8444/browse/J305-2694 https://10.0.1.102:8444/browse/J305-2694 https://10.0.1.102:8444/browse/J305-2627 https://10.0.1.102:8444/browse/J305-2627 https://10.0.1.102:8444/browse/J305-2389 https://10.0.1.102:8444/browse/J305-2389 https://10.0.1.102:8444/browse/J305-2230 https://10.0.1.102:8444/browse/J305-2230
ECP# Device Key Summary Description Status Created Updated
ECP
010-12
MH-60T
CPT
J305-
MH-60T CPT Image Generator and Host/IOS Computer Systems Replacement
Desired functionality: To have the same "gaming" areas and IOS visual/environmental cues control on both the CPT and OFT.
Reason for the change: To allow the use of identical training scenarios on both the CPT and OFT. To be able to utilize the CPT as a fully functional backup device, with respect to training scenarios, for the OFT. This would also allow us to run virtually the same simulation code on the CPT that the OFT utilizes.
In Progress 4-Mar-13 25-May-16
ECP51 HH-65C
OFT
J305-
HH-65C OFT Weather Radar Simulator Replacement
Current radar simulation is correlated to current XIG databases. New Pc Nova IG will have other gaming areas not currently covered with the existing radar simulation. Refresh the radar simulation and ensure radar database coverage provides radar capabilities in and correlates with all PC Nova IG gaming areas (except SE US). Provide an option to generate a usable radar database for the SE US gaming area.
Ready For Customer Recheck
14-Sep-11 23-Mar-16 https://10.0.1.102:8444/browse/J305-2012 https://10.0.1.102:8444/browse/J305-2012 https://10.0.1.102:8444/browse/J305-225 https://10.0.1.102:8444/browse/J305-225
Appendix C
Engineering Change Notice Summary
ECNs Open or Closed this Reporting Period – July 2017
Device Key/ECN Number
Description Drawing Number
Status Created Updated
MH-60T OFT J305-9555
CHANGE 307A505267 QA 19-Jul-17 24-Jul-17
MH-60T OFT J305-9553
New drawing 707A120040 D/D 19-Jul-17 27-Jul-17
MH-60T OFT J305-9552
N/A 707a509014 QA 19-Jul-17 19-Jul-17
AWT J305-9538
Create drawing to document cabin lighting HS5-003-EI004 D/D 17-Jul-17 28-Jul-17
MH-60T OFT J305-9519
LABELED WRONG FOR LOCATION 707A509051 QA 13-Jul-17 20-Jul-17
MH-60T OFT J305-9482
To update the location of the Ethernet on the host SD-28-00019 QA 6-Jul-17 6-Jul-17
MH-65D OFT J305-9414
Replaced network switch (3A2A6) 048E543008 Logistics 19-Jun-17 26-Jun-17
HC-144 OFT J305-9321
ADDED USB EXTENDER 315A120000 Logistics 30-May-17 8-Jun-17
MH-65D OFT J305-9273
Replaced network switch (3A2A6) 048M300100 D/D 16-May-17 7-Jun-17
MH-65D OFT J305-9262
Add FTS LAN isolation router 048M303000 QA 16-May-17 25-May-17
MH-65D OFT J305-9261
Add Christie (Display) Laptop 048M000035 QA 16-May-17 25-May-17
MH-65D OFT J305-9260
Add cables 3W142 (-30), 3W143 (-31), 3W144 (-32), 3W145 (-33), 3W146 (-34)
048E543053 Logistics 16-May-17 19-Jun-17
MH-65D OFT J305-9258
Add cables W83 (-15) & W84 (-16) 048E540011 Logistics 16-May-17 23-May-17
MH-65D OFT J305-9257
Replaced network switch (3A2A6). Isolate Host / Control Loading communications. Update trainer network configuration
048E000008 Logistics 16-May-17 20-Jun-17
HC-144 OFT J305-9238
Deleting 315A213214 due to ECP 003-15 315A213214 CM Vault 11-May-17 11-May-17
MH-65D OFT J305-9224
Added 4 port ethernet card to Host 048M300300 D/D 9-May-17 2-Jun-17
HC-144 OFT J305-9223
REPLACING HCU FLIR WITH THE UHCU, as per ECP 003-15 315A210100 Prepared 9-May-17 22-May-17
HC-144 OFT J305-9222
BACK PLATE FOR FLIR NOT BEING USED, as per ECP 003-15 315A213213 CM Vault 9-May-17 11-May-17
HC-144 OFT J305-9221
HCU IS BEING REPLACED, as per ECP 003-15 315A213210_PL CM Vault 9-May-17 11-May-17
HC-144 OFT J305-9220
DELETE THIS DWG, as per ECP 003-15 315A213210 CM Vault 9-May-17 11-May-17
MH-65D2
OFT
J305-9035
ECP- 014-16
ICS upgrade for the IOS and observer stations
405513 QA 1-Apr-17 18-May-17
HC-144 OFT J305-8836
KVM UPGRADE
ECP 009-15
315A500284 QA 16-Feb-17 26-May-17
HC-144 OFT J305-8835
KVM UPGRADE
ECP 009-15
315A500127 QA 16-Feb-17 25-May-17
HC-144 OFT J305-8834
KVM UPGRADE
ECP 009-15
315A500126 QA 16-Feb-17 25-May-17 https://10.0.1.102:8444/browse/J305-9555 https://10.0.1.102:8444/browse/J305-9553 https://10.0.1.102:8444/browse/J305-9552 https://10.0.1.102:8444/browse/J305-9538 https://10.0.1.102:8444/browse/J305-9519 https://10.0.1.102:8444/browse/J305-9482 https://10.0.1.102:8444/browse/J305-9414 https://10.0.1.102:8444/browse/J305-9321 https://10.0.1.102:8444/browse/J305-9273 https://10.0.1.102:8444/browse/J305-9262 https://10.0.1.102:8444/browse/J305-9261 https://10.0.1.102:8444/browse/J305-9260 https://10.0.1.102:8444/browse/J305-9258 https://10.0.1.102:8444/browse/J305-9257 https://10.0.1.102:8444/browse/J305-9238 https://10.0.1.102:8444/browse/J305-9224 https://10.0.1.102:8444/browse/J305-9223 https://10.0.1.102:8444/browse/J305-9222 https://10.0.1.102:8444/browse/J305-9221 https://10.0.1.102:8444/browse/J305-9220 https://10.0.1.102:8444/browse/J305-9035 https://10.0.1.102:8444/browse/J305-8836 https://10.0.1.102:8444/browse/J305-8835 https://10.0.1.102:8444/browse/J305-8834
Device Key/ECN Number
Description Drawing Number
Status Created Updated
HC-144 OFT J305-8833 KVM UPGRADE
ECP 009-15
315A600080 Prepared 16-Feb-17 5-Jun-17
MH-60T OFT J305-8797 KVM UPGRADE
ECP 014-13
307A505270 QA 13-Feb-17 13-Feb-17
MH-60T OFT J305-8796 KVM UPGRADE
ECP 014-13
204C505146 QA 13-Feb-17 13-Feb-17
MH-60T OFT J305-8794 KVM UPGRADE
ECP 014-13
185C505121 Logistics 13-Feb-17 2-May-17
MH-60T OFT J305-8784 KVM UPGRADE
ECP 011-015
204C505145 QA 9-Feb-17 10-Feb-17
MH-60T OFT J305-8783 KVM UPGRADE
ECP 011-015
204C505144 QA 9-Feb-17 10-Feb-17
MH-60T OFT J305-8765 KVM UPGRADE
ECP 011-015
204C505143 QA 7-Feb-17 15-Feb-17
MH-60T OFT J305-8757 KVM UPGRADE
ECP 011-015
707A509020 QA 6-Feb-17 9-Feb-17
MH-60T OFT J305-8747 KVM UPGRADE
ECP 011-015
204C505141 QA 3-Feb-17 3-Feb-17
MH-60T OFT J305-8746 KVM UPGRADE
ECP 011-015
204C505142 QA 3-Feb-17 3-Feb-17
MH-60T OFT J305-8736 KVM UPGRADE
ECP 011-015
204C505136 Logistics 2-Feb-17 2-May-17
MH-60T OFT J305-8729 KVM UPGRADE
ECP 011-15
204C505135 Logistics 1-Feb-17 2-May-17
MH-60T OFT J305-8714 KVM UPGRADE
ECP 011-015
307A505258 Logistics 30-Jan-17 8-May-17
MH-60T OFT J305-8713 KVM UPGRADE 307A505251 Logistics 30-Jan-17 2-Jun-17
MH-60T OFT J305-8711 KVM UPGRADE
ECP 011-015
602001 QA 30-Jan-17 15-Feb-17
MH-60T OFT J305-8710 KVM UPGRADE
ECP 011-015
185C120000 QA 30-Jan-17 21-Jul-17
MH-60T OFT J305-8708 KVM UPGRADE
ECP 011-015
707A600005 QA 30-Jan-17 7-Feb-17
MH-60T OFT J305-8707 KVM Upgrade
ECP 011-015
307A616000 QA 30-Jan-17 6-Jun-17
MH-60T OFT J305-8678 Upgrade from DAQS to Telestra
ECP 014-13
307A505282 QA 24-Jan-17 25-Jan-17 https://10.0.1.102:8444/browse/J305-8833 https://10.0.1.102:8444/browse/J305-8797 https://10.0.1.102:8444/browse/J305-8796 https://10.0.1.102:8444/browse/J305-8794 https://10.0.1.102:8444/browse/J305-8784 https://10.0.1.102:8444/browse/J305-8783 https://10.0.1.102:8444/browse/J305-8765 https://10.0.1.102:8444/browse/J305-8757 https://10.0.1.102:8444/browse/J305-8747 https://10.0.1.102:8444/browse/J305-8746 https://10.0.1.102:8444/browse/J305-8736 https://10.0.1.102:8444/browse/J305-8729 https://10.0.1.102:8444/browse/J305-8714 https://10.0.1.102:8444/browse/J305-8713 https://10.0.1.102:8444/browse/J305-8711 https://10.0.1.102:8444/browse/J305-8710 https://10.0.1.102:8444/browse/J305-8708 https://10.0.1.102:8444/browse/J305-8707 https://10.0.1.102:8444/browse/J305-8678
Device Key/ECN Number
Description Drawing Number
Status Created Updated
MH-60T OFT J305-8661 Upgrade from daqs to Telestra
ECP 014-13
307A244000 Logistics 20-Jan-17 4-May-17
MH-60T OFT J305-8656 Change from daqs to Telestra
ECP 014-13
307A244160 Logistics 19-Jan-17 4-May-17
MH-60T OFT J305-8643 KVM upgrade
ECP 011-15
707A620010 Logistics 18-Jan-17 10-Jul-17
MH-60T OFT J305-8630 KVM UPGRADE
ECP 011-15
185C505027 QA 13-Jan-17 14-Feb-17
MH-60T OFT J305-8629 KVM UPGRADE
ECP 011-15
185C505026 Logistics 13-Jan-17 1-May-17
MH-60T OFT J305-8609 KVM UPGRADE
ECP 014-13
185C505025 QA 11-Jan-17 14-Feb-17
MH-60T OFT J305-8608 Upgrade from daqs to Telestra
ECP 014-13
185C505001 QA 11-Jan-17 2-Jun-17
MH-60T OFT J305-8607 Upgrade from daqs to Telestra
ECP 014-13
500B003 QA 11-Jan-17 16-Feb-17
MH-60T OFT J305-8606 Upgrade from daqs to Telestra
ECP 014-13
185C505012 Logistics 11-Jan-17 8-May-17
MH-60T OFT J305-8592 Upgrade from DAQS to Telestra
ECP 014-13
185C600009 Logistics 10-Jan-17 10-Jul-17
MH-60T OFT J305-8590 ECP 014-13
Update drawings to match current config
185C120030 Logistics 10-Jan-17 5-May-17
MH-60T OFT J305-8556 ECP016-14 Bad ELF 707A509060 Logistics 28-Dec-16 1-May-17 MH-60T OFT J305-8555 ECP016-14 Bad ELF 707A508406 Logistics 28-Dec-16 1-May-17 MH-60T OFT J305-8554 ECP016-14 Bad ELF 185C505008 QA 28-Dec-16 15-Feb-17 MH-60T OFT J305-8552 ECP016-14 Bad ELF 707A509051 QA 27-Dec-16 1-Apr-17 MH-60T OFT J305-8551 ECP016-14 Bad ELF 185C505005 QA 27-Dec-16 25-Jan-17 MH-60T OFT J305-8550 ECP016-14 Bad ELF 307A505248 QA 27-Dec-16 7-Jun-17 MH-60T OFT J305-8549 ECP016-14 Bad ELF 707A509018 Logistics 27-Dec-16 1-May-17 MH-60T OFT J305-8548 ECP016-14 Bad ELF 707A509017 Logistics 27-Dec-16 1-May-17
MH-65D2
OFT
J305-8459 VEMD TOT configuration resistors connections not shown correctly.
Drawing does not reflect trainer configuration
284B611020 Project Engr 30-Nov-16 12-Jul-17
HC-144 OFT J305-8397 ECP003-15 FLIR UHCU 315A501023 QA 15-Nov-16 2-Jun-17 HC-144 OFT J305-8386 ECP003-15 FLIR UHCU 315A501022 D/D 10-Nov-16 2-Jun-17 HC-144 OFT J305-8385 ECP003-15 FLIR UHCU 315A500300 Logistics 10-Nov-16 20-Jun-17 HC-144 OFT J305-8384 ECP003-15 FLIR UHCU 315A120000 D/D 10-Nov-16 2-Jun-17 https://10.0.1.102:8444/browse/J305-8661 https://10.0.1.102:8444/browse/J305-8656 https://10.0.1.102:8444/browse/J305-8643 https://10.0.1.102:8444/browse/J305-8630 https://10.0.1.102:8444/browse/J305-8629 https://10.0.1.102:8444/browse/J305-8609 https://10.0.1.102:8444/browse/J305-8608 https://10.0.1.102:8444/browse/J305-8607 https://10.0.1.102:8444/browse/J305-8606 https://10.0.1.102:8444/browse/J305-8592 https://10.0.1.102:8444/browse/J305-8590 https://10.0.1.102:8444/browse/J305-8556 https://10.0.1.102:8444/browse/J305-8555 https://10.0.1.102:8444/browse/J305-8554 https://10.0.1.102:8444/browse/J305-8552 https://10.0.1.102:8444/browse/J305-8551 https://10.0.1.102:8444/browse/J305-8550 https://10.0.1.102:8444/browse/J305-8549…