Attachment#8-PAR 56 300W Production Unit Test Plan- Procedure Form 10-24-2017_FINAL.docx

DOCX document 80 KB Posted

Attached to
SIR/RFO - Par-56, 300 Watt, Incandescent Lamps
Solicitation number
6973GH-18-R-00028
Issued by

About this file

Attachment#8-PAR 56 300W Production Unit Test Plan- Procedure Form 10-24-2017_FINAL (docx)

View the file

Other files

File Type Posted
Attachment #9-PAR 56 300W Production Unit Test and Test Result Form 10-24-17_FINAL.docx DOCX document
Attachment #1-PAR 56 300W SOW 11-29-2017 Revision I.pdf PDF
6973GH-18-R-00028-A0001.pdf PDF
6973GH-18-R-00028-A0002.pdf PDF
Attachment #4-Past Performance Questionnaire UPDATEDFINAL.pdf PDF
Attachment #3-ORGANIZATIONAL EXPERIENCE INFORMATION.pdf PDF
6973GH-18-R-00028_Final.pdf PDF
Attachment#8-PAR 56 300W Production Unit Test Plan- Procedure Form 10-24-2017_FINAL.docx DOCX document
Attachment #5-ANSI_ASQCZ1-4-1993.pdf PDF
Attachment #6-PAR 56 300W First Article Test Plan- Procedure Form 10-24-2017_FINAL.docx DOCX document
Attachment #1-PAR 56 300W SOW 10-31-2017_FINAL.pdf PDF
Attachment #4-Past Performance Questionnaire Revision I.pdf PDF
Attachment #2-PAR 56 300W CDRLs-DIDs 11-29-2017.pdf PDF
Attachment #7-PAR 56 300W First Article Test Procedure and Result Form Changes 11-29-2017.pdf PDF
Attachment #9-PAR 56 300W Production Unit Test and Test Result Form 11-29-17.pdf PDF
Attachment #7-PAR 56 300W First Article Test Procedure and Result Form 10-30-2017_FINAL.docx DOCX document
Attachment #2-PAR 56 300W CDRLs-DIDs 10-31-2017_FINAL.pdf PDF
Attachment #4-Past Performance Questionnaire UPDATEDFINAL.pdf PDF
Attachment #3-ORGANIZATIONAL EXPERIENCE INFORMATION.pdf PDF
Attachment #1-PAR 56 300W SOW 10-31-2017_FINAL.pdf PDF
Attachment #2-PAR 56 300W CDRLs-DIDs 11-29-2017.pdf PDF
Attachment #9-PAR 56 300W Production Unit Test and Test Result Form 11-29-17.pdf PDF
Attachment #4-Past Performance Questionnaire Revision I.pdf PDF
Attachment #1-PAR 56 300W SOW 11-29-2017 Revision I.pdf PDF
Attachment #7-PAR 56 300W First Article Test Procedure and Result Form 10-30-2017_FINAL.docx DOCX document
6973GH-18-R-00028-A0001.pdf PDF
Attachment #2-PAR 56 300W CDRLs-DIDs 10-31-2017_FINAL.pdf PDF
Attachment #9-PAR 56 300W Production Unit Test and Test Result Form 10-24-17_FINAL.docx DOCX document
Attachment #6-PAR 56 300W First Article Test Plan- Procedure Form 10-24-2017_FINAL.docx DOCX document
Attachment #7-PAR 56 300W First Article Test Procedure and Result Form Changes 11-29-2017.pdf PDF
6973GH-18-R-00028_Final.pdf PDF
Attachment #5-ANSI_ASQCZ1-4-1993.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

October 24, 2017

Production Unit Test Plan/ Procedure Form.

For FAA 20A 300W Par 56

Q20A/PAR-56/C INCANDESCENT LAMP

TYPE I, MOGUL END PRONG, 300W
NSN: 6240-01-432-3996

1.0 Scope

1.1 The specifications covers halogen-cycle PAR-56 aviation service lamps or equivalent used for runway approach lighting systems.

1.2 Reference FAA-E-2408b Dated July 31, 2000.

1.3 This procedure will outline any and all test requirements for production build units.

1.4 A test sample rate of 5pcs or 1% whichever is greater shall be tested per production batch.

2.0 Test Equipment List with calibration date (as need).

List all of the equipment

3.0 Test methods

Testing of the UUT shall be performed IAW FAA-E-2408b Dated July 31, 2000, Appendix B of Par-56, 300 watt, Incandescent Lamp Statement of Work.

4.0 Wattage rating test (paragraph 4.5.1)

Test set up and procedure: (prepare by contractor)

5.0 Filament Motion and Shorting Test (paragraph 4.5.2)

6.0 Photometric Testing (paragraph 4.5.4)

Photometric tests shall be conducted to demonstrate compliance with the intensity and beam dimension requirements of Table I, as applicable. Table 2 is used to fill the photometric required in table 1.

Table I. Lamp Design Parameters (Mogul End Prong, Type I)

Q20A/PAR56/C

Wattage Rating

200
±16
300
+18
500 ±30
Rated Amperes
(RMS)
6.6
±0.5%
20
±0.5%
20 ±0 . 5%
Average Life,
Hours
1000
300
+18
Rated Amperes
(RMS)
20
±0.5%
Average Life,
Hours

Minimum Candela Requirements Within Beam Field Point Location (degrees from mechanical axis)

3.5 up - 13.5 left

7,000

3.5 down - 13.5 left

7,000

3.5 up - 13.5 right

7,000

3.5 down - 13.5 right

7,000

4 up - vertical

16,000

4 down - vertical horizontal - 10 left horizontal - 10 right

16,000 16,000 16,000 horizontal - 14 left

7,000 horizontal - 14 right

7,000

Maximum Intensity, 48,000

Candela (not to be exceeded in any direction)

Cover Glass
Prismatic

Prismatic Prismatic

Base
All three
(3)
lamps - Mogul End Prong
Burning Position
All three
(3)
lamps - Horizontal to 25°

Base Down

Sample No: Flash Period: On time-one flash:

Brightness Step:

Style: Input:

Neutral Density Filter: Calibration Factor:

Serial #

NA I

Vertical Position (deg.)

Calculated Effective Intensity Data (candela)

Horizontal Position (deg.)

15L
14L
13.5 L
10L
11L
7.5L
5L
0
5R
7.5R
10R
12R

13.5 R

14R

5U

4U

3.5U

2.5U

1U

1D

2.5D

3.5D

4D

5D

Table 2: Photometric Test Data for S/N:

7.0 Two Hour Test (paragraph 4.5.13)

8.0 Examination Of Product (paragraph 4.4.1)

9.1 The lamp shall be inspected to determine compliance with the requirements specified herein with respect to materials, workmanship and marking. The lamp shall be inspected to determine that outline dimensions meet the dimensions given in Figure 1 as applicable. Lamp prongs shall be flat any curvature in design shall be cause for rejection. Record Inspection results on data sheet.

List of test

5.0 Filament Motion Test and Shorting of Turn Test

6.0 Photometric Test

7.0 Two Hour Test

8.0 Examination of Product

Prepared for: FAA Logistics Center

Name of Company:

Address:

Phone number:

Prepared By:

Title:

Date: ______________