1 | P a g e
November/21/ 2017
Production Unit Test Result Form.
For FAA 20A 300W Par 56
Q20A/PAR-56/C INCANDESCENT LAMP
TYPE I, MOGUL END PRONG, 300W
NSN: 6240-01-432-3996
1.0 Scope
1.1 The specifications covers halogen-cycle PAR-56 aviation service lamps or equivalent used for runway approach lighting systems.
1.2 Reference FAA-E-2408b Dated July 31, 2000.
1.3 This procedure will outline any and all test requirements for production build units.
1.4 A test sample rate of 5pcs or 1% whichever is greater shall be tested per production batch.
2.0 Test Equipment List with calibration date (as need).
List all of the equipment
3.0 Test methods
Testing of the UUT shall be performed IAW FAA-E-2408b Dated July 31, 2000.
4.0 Wattage rating test (paragraph 4.5.1)
Test set up and procedure: (prepare by contractor)
5.0 Filament Motion and Shorting Test (paragraph 4.5.2)
Test set up and procedure:
(prepare by contractor)
2 | P a g e
6.0 Photometric Testing (paragraph 4.5.4)
Photometric tests shall be conducted to demonstrate compliance with the intensity and beam dimension requirements of Table I, as applicable.
Table 2 is used to fill the photometric required in table 1.
Table I. Lamp Design Parameters (Mogul End Prong, Type I)
Q20A/PAR56/C
Wattage Rating
300 +18
Rated Amperes
20 ±0.5%
Average Life, Minimum Candela Requirements Within Beam Field Point Location (degrees from mechanical axis)
3.5 up - 13.5 left 7,000
3.5 down - 13.5 left 7,000
3.5 up - 13.5 right 7,000
3.5 down - 13.5 right 7,000
4 up - vertical 16,000 4 down - vertical horizontal - 10 left horizontal - 10 right
16,000
16,000 16,000 horizontal - 14 left 7,000 horizontal - 14 right 7,000
Maximum Intensity, 48,000 Candela (not to be exceeded in any direction)
Cover Glass Prismatic
Prismatic Prismatic
Base All three (3) lamps - Mogul End Prong
Burning Position All three (3) lamps - Horizontal to 25°
Base Down
3 | P a g e
Sample No:
Flash Period: On t ime-one flash:
Brightness Step:
Style:
Input:
Neutral Density Filter:
Calibration Factor:
Serial #
NA I
Vertical Position (deg.)
Calculated Effective Intensity Data (candela) Horizontal Position (deg.)
15L 14L 13.5 L 10L 11L 7.5L 5L 0 5R 7.5R 10R 12R
13.5 R 14R
5U 4U
3.5U 2.5U 1U
1D 2.5D 3.5D 4D 5D
Table 2: Photometric Test Data for S/N:
4 | P a g e
7.0 Two Hour Test (paragraph 4.5.13)
8.0 Examination Of Product (paragraph 4.4.1)
9.1 The lamp shall be inspected to determine compliance with the requirements specified herein with respect to materials, workmanship and marking. The lamp shall be inspected to determine that outline dimensions meet the dimensions given in Figure 1 as applicable. Lamp prongs shall be flat any curvature in design shall be cause for rejection.
Record Inspection results on data sheet.
5 | P a g e
Prepared for: FAA Logistics Center
Name of Company:
Address:
Phone number:
Prepared By:
Title:
Test By:
Title:
Date: ______________
Part Name: _____________________
Manufacture Part Number: ______________________
NSN:_____________________________
Production Date Code: _________________
Production Build QTY: ______________
Sample rate of 5 pcs or 1% whichever is greater shall be tested.
QTY: No Lamp Fail – all five Lamp should pass
List of test performed and attach the test result for each test.
4.0 Wattage Rating Test
5.0 Filament Motion Test and Shorting of Turn Test
6.0 Photometric Test
7.0 Two Hour Test
9.0 Examination of Product
6 | P a g e
Test Equipment Used Calibration Date Calibration Due Date
7 | P a g e
Lamp # – serial number
4.0 Wattage Rating Test
Details/Requirements Results UUT start date/time
Measured current at start 20 Amps +/-.5%(19.1-20.1)
Actual measured:
pass/fail
Measured voltage at start 15 Volts nominal
Time accumulated on UUT 5 hour minimum
Measured current after 5 hours
Measured voltage after 5 hours
Calculated watts 300 Watt
8 | P a g e
5.0 Filament Motion and Shorting Test: Date/Time:
Details/Requirements Measured Results Measured current at start
15 min interval Measured voltage within +/-0.5 volts of original Measurement
30 min interval Measured voltage within
60 min interval Measured voltage within
120 min interval Measured voltage within
9 | P a g e
6.0 Photometric Testing. Date performed: ____________
Measured Voltage:___________ 15 V Nominal
Measured Current:___________ 20Amps +/-.5%(19.9-20.1)
Max Candela Measurement 48,000 Max Candela allowed
Actual Measured___________ pass/fail
3.5°up 13.5°left Reading 7,000 Candela Min.
3.5°down 13.5°left Reading
3.5° up 13.5° Right Reading
3.5°down 13.5° Right Reading
4.0°up 0°Vertical Reading 16,000 Candela Min.
4.0°down 0°Vertical Reading
0°Horizontal 10°Left Reading
0°Horizontal 10°Right Reading
0°Horizontal 14°Left Reading
0°Horizontal 14°Right Reading
10 | P a g e
(deg.)
Calculated Effective Intensity Data (candela)
4U
3.5U 2.5U 1U
1D 2.5D 3.5D 4D
7.0 Two Hour Test, Date
Start time:
Stop time:
Pass Fail
9.0 Examination of Product Pass Fail
11 | P a g e
Details/Requirements Results UUT start date/time
12 | P a g e
Measured voltage within
30 min interval Measured voltage within
60 min interval Measured voltage within
120 min interval Measured voltage within
13 | P a g e
Measured Current:___________ 20Amps +/-.5%(19.9-20.1)
14 | P a g e
(deg.)
Calculated Effective Intensity Data (candela)
4U
3.5U 2.5U 1U
1D 2.5D 3.5D 4D
9.0 Examination of Product Pass Fail
15 | P a g e
Details/Requirements Results UUT start date/time
15 Voltsnominal
16 | P a g e
Measured voltage within
30 min interval Measured voltage within
60 min interval Measured voltage within
120 min interval Measured voltage within
17 | P a g e
Measured Current:___________ 20Amps +/-.5%(19.9-20.1)
18 | P a g e
(deg.)
Calculated Effective Intensity Data (candela)
4U
3.5U 2.5U 1U
1D 2.5D 3.5D 4D
9.0 Examination of Product Pass Fail
19 | P a g e
Details/Requirements Results UUT start date/time
20 | P a g e
Measured voltage within
30 min interval Measured voltage within
60 min interval Measured voltage within
120 min interval Measured voltage within
21 | P a g e
Measured Current:___________ 20Amps +/-.5%(19.9-20.1)
22 | P a g e
(deg.)
Calculated Effective Intensity Data (candela)
4U
3.5U 2.5U 1U
1D 2.5D 3.5D 4D
9.0 Examination of Product Pass Fail
23 | P a g e
Details/Requirements Results UUT start date/time
24 | P a g e
Measured voltage within
30 min interval Measured voltage within
60 min interval Measured voltage within
120 min interval Measured voltage within
25 | P a g e
Measured Current:___________ 20Amps +/-.5%(19.9-20.1)
26 | P a g e
(deg.)
Calculated Effective Intensity Data (candela)
4U
3.5U 2.5U 1U
1D 2.5D 3.5D 4D
27 | P a g e
9.0 Examination of Product Pass Fail