1 | P a g e
11/21/2017
First Article Test Plan/Procedure Form
For FAA 20A 300W Par 56
Q20A/PAR-56/C INCANDESCENT LAMP
TYPE I, MOGUL END PRONG, 300W
NSN: 6240-01-432-3996
1.0 Scope
1.1 The specifications covers halogen-cycle PAR-56 aviation service lamps or equivalent used for runway approach lighting systems.
1.2 Reference FAA-E-2408b Dated July 31, 2000.
1.3 This procedure will outline any and all test requirements for production build units.
1.4 A test sample rate of 5pcs or 1% whichever is greater shall be tested per production batch.
2.0 Test Equipment List with calibration date (as need).
List all of the equipment (page 9 of this document)
3.0 Test methods
Testing of the UUT shall be performed IAW FAA-E-2408b Dated July 31, 2000, paragraph 4.5.
4. Examination of product (Reference 4.4.1 in FAA-E-2408 b, dated July 31, 2000)
5. Wattage rating test. (Reference 4.5.1 in FAA-E-2408B Dated July 31, Test set up and procedure (prepare by contractor):
6. Filament Motion and Shorting Test (Reference 4.5.2 in FAA-E-2408B Dated July 31, 2000)
2 | P a g e
7. Life Test. (Reference 4.5.3 in FAA-E-2408B Dated July 31, 2000)
8. Photometric Testing (Reference 4.5.4 in FAA-E-2408B Dated July 31, Photometric tests shall be conducted to demonstrate compliance with the intensity and beam dimension requirements of Table I, as applicable.
Table 2 is used to fill the photometric required in table 1.
Table I. Lamp Design Parameters (Mogul End Prong, Type I)
Q20A/PAR56/C
Wattage Rating
300 +18
Rated Amperes
20 ±0.5%
Average Life, Minimum Candela Requirements Within Beam Field Point Location (degrees from mechanical axis)
3.5 up - 13.5 left 7,000
3.5 down - 13.5 left 7,000
3.5 up - 13.5 right 7,000
3.5 down - 13.5 right 7,000
4 up - vertical 16,000 4 down - vertical horizontal - 10 left horizontal - 10 right
16,000
16,000 16,000 horizontal - 14 left 7,000
3 | P a g e horizontal - 14 right 7,000
Maximum Intensity, 48,000 Candela (not to be exceeded in any direction)
Cover Glass Prismatic
Prismatic Prismatic
Base All three (3) lamps - Mogul End Prong
Burning Position All three (3) lamps - Horizontal to 25° Base Down
4 | P a g e
Sample No:
Flash Period: On t ime-one flash:
Brightness Step:
Style:
Input:
Neutral Density Filter:
Calibration Factor:
Serial #
NA I
Vertical Position (deg.)
Calculated Effective Intensity Data (candela) Horizontal Position (deg.)
15L 14L 13.5 L 10L 11L 7.5L 5L 0 5R 7.5R 10R 12R 1 3 . 5
R 14R 5U 4U
3.5U 2.5U 1U
1D 2.5D 3.5D 4D 5D
Table 2 for Photometric Test Data for S/N:
9. Light Maintenance (Reference 4.5.5 in FAA-E-2408B Dated July 31, Thermal shock test ( Reference 4.5.6)
10 . Cold Water Test (Reference 4.5.6.1 in FAA-E-2408B Dated July 31, 2000): Can be performed in the last test
11. Icing Test (Reference 4.5.6.2 in FAA-E-2408B Dated July 31, 2000) Can be performed after cold water test
5 | P a g e
Temperature Test (Reference 4.5.7):
12. High Temperature Test (Reference 4.5.7.1 in FAA-E-2408B Dated July 31, 2000)
13. Low Temperature Test (Reference 4.5.7.2 in FAA-E-2408B Dated July 31, 2000)
14. Vibration Test (Reference 4.5.8, 4.5.8.1 in FAA-E-2408B Dated July 31, 2000)
15. Humidity Test (Reference 4.5.9 in FAA-E-2408B Dated July 31, 2000)
16. Low Pressure (Altitude) Test (Reference 4.5.10 in FAA-E-2408B Dated July 31, 2000)
17. Salt Fog Test (Reference 4.5.11 in FAA-E-2408B Dated July 31, 2000)
18. Rain Test (Reference 4.5.12 in FAA-E-2408B Dated July 31, 2000)
6 | P a g e
19. Two Hour Test (Reference 4.5.13 in FAA-E-2408B Dated July 31,
20. Solar Radiation Test (Reference 4.5.14 in FAA-E-2408B Dated July 31, The solar radiation (sunshine) test shall be performed IAW Procedure II, method 505.4, of MIL-STD-810F. An irradiance of 1120 watts per square meter shall be applied to the lamp coating for 630 days. At the end of the test the lamp coating transmittance shall be 95% of the initial transmittance, and the lamp at rated life shall meet the 80% light maintenance requirement. (9.0)
7 | P a g e
Figure1 Lamp Design Parameters (Mogul End Prong) Type
8 | P a g e
Prepared for: FAA Logistics Center
Name of Company:
Address:
Phone number:
Prepared By:
Title:
Date: ______________
List of test IAW FAA-E-2408b Dated July 31, 2000.
4.0 Examination of Product
5.0 Wattage Rating Test
6.0 Filament Motion Test and Shorting of Turn Test
7.0 Life Test
8.0 Photometric Test
9.0 Light Maintenance Test
10.0 Cold water test
11.0 Icing Test
12.0 High Temperature Test
13.0 Low Temperature Test
14.0 Vibration Test
15.0 Humidity Test
16.0 Low Pressure (Altitude Test)
17.0 Salt Fog Test
18.0 Rain Test
19.0 Two Hour Test
20 .0 Solar Radiation Test
9 | P a g e
LIST of Test Equipment and calibration date:
Test Equipment Used Calibration Date Calibration Due Date
10 | P a g e
TEST REUSULS:
All UUT’s have passed the Statement of Work requirements IAW FAA-E- 2408b Dated July 31, 2000.
Total of Lamps:
LAMP 1
PASS / FAIL
5.0 Wattage Rating Test
Details/Requirements Results UUT start date/time
Measured current at start 20 Amps +/-.5%(19.1-20.1)
Actual measured:
pass/fail
Measured voltage at start 15 Volts nominal
Time accumulated on UUT 5 hour minimum
Measured current after 5 hours
Measured voltage after 5 hours
Calculated watts 300Watt
11 | P a g e
6.0 Filament Motion and Shorting Test: Date/Time:
Details/Requirements Measured Results Measured current at start
15 min interval Measured voltage within +/-0.5 volts of original Measurement
30 min interval Measured voltage within
60 min interval Measured voltage within
120 min interval Measured voltage within
12 | P a g e
7.0 Life Test:
Measured Current at Start of Test:
20Amps +/-.5% (19.9-20.1) pass/fail
Measured Voltage at Start of Test:
15V nominal pass/fail Life Test Start Date/Time:
Life Test End Date/Time:
Accumulated Hours on UUT:
500Hour Min. pass/fail Measured Current at End of Test:
20Amps +/-.5% (19.9-20.1) pass/fail Measured Voltage at End of Test:
Cannot measure greater than 6% pass/fail Measured value at start of test.
6.3 Measured Max. Candela after Lite
Test:
Candela measurement cannot fall Below 80% of original Candela pass/fail Measurement.
13 | P a g e
8.0 Photometric Testing. Date performed: ____________
Measured Voltage:___________ 15V Nominal
Measured Current:___________ 20Amps +/-.5%(19.9-20.1)
4.9 4.0°up Vertical Reading 16,000 Candela Min.
Actual Measured___________ pass/fail
4.4 Max Candela Measurement
48,000 Max Candela allowed
Actual Measured___________ pass/fail
4.10 4.0°down Vertical Reading 16,000 Candela Min.
Actual Measured___________ pass/fail
4.5 3.5°up 13.5°left Reading 7,000 Candela Min.
4.11 0°Horizontal 10°Left Reading
4.6 3.5°down 13.5°left Reading 7,000 Candela Min.
Actual
Measured___________ pass/fail
4.11 0°Horizontal 10°right Reading
4.7 3.5°up 13.5°right Reading
4.12 0°Horizontal 14°left Reading
4.8 3.5° down,13.5°right Reading 7,000 Candela Min.
Actual Measured___________ pass/fail
0°Horizontal 14° right Reading
14 | P a g e
9.0 Light Maintenance Test -
Date performed:
Recorded measurement:
Pass/Fail
10. Cold Water Test
Recorded measurement and test results
11. Icing Test
12.0 High Temperature Test
15 | P a g e
13.0 Low Temperature Test
14.0 Vibration Test
Recorded measurement and test results
15.0 Humidity Test
Pass/Fail
16.0 Low Pressure (Altitude Test)
Date performed:
Recorded measurement and test results Pass/Fail
17.0 Salt Fog Test
Date performed:
Recorded measurement and test results
18.0 Rain Test
16 | P a g e
Pass/Fail 20 .0 Solar Radiation Test: provide a signed Certificate of Conformance that states their lamps meet the environmental requirements of that test and FAA- E-2408b section 3.5.8.
17 | P a g e
LAMP 2
UUT start date/time
18 | P a g e
Measured voltage within
30 min interval Measured voltage within
60 min interval Measured voltage within
120 min interval Measured voltage within
19 | P a g e
Measured Current at Start of Test:
20Amps +/-.5% (19.9-20.1) pass/fail
Measured Voltage at Start of Test:
15V nominal pass/fail Life Test Start Date/Time:
Life Test End Date/Time:
Accumulated Hours on UUT:
500Hour Min. pass/fail Measured Current at End of Test:
20Amps +/-.5% (19.9-20.1) pass/fail Measured Voltage at End of Test:
Cannot measure greater than 6% pass/fail Measured value at start of test.
6.3 Measured Max. Candela after Lite
Test:
Candela measurement cannot fall Below 80% of original Candela pass/fall
20 | P a g e
Measured Current:___________ 20Amps +/-.5%(19.9-20.1)
4.9 4.0°up Vertical Reading 16,000 Candela Min.
Actual Measured___________ pass/fail
4.4 Max Candela Measurement
48,000 Max Candela allowed
Actual Measured___________ pass/fail
4.6 3.5°down 13.5°left Reading 7,000 Candela Min.
Actual
Measured___________ pass/fail
4.8 3.5° down,13.5°right Reading 7,000 Candela Min.
Actual Measured___________ pass/fail
21 | P a g e
13.0 Low Temperature Test
Date performed:
22 | P a g e
Recorded measurement and test results
Pass/Fail
16.0 Low Pressure (Altitude Test)
Date performed:
Recorded measurement and test results Pass/Fail
17.0 Salt Fog Test
Date performed:
Recorded measurement and test results
23 | P a g e
20 .0 Solar Radiation Test: provide a signed Certificate of Conformance that states their lamps meet the environmental requirements of that test and FAA- E-2408b section 3.5.8.
24 | P a g e
LAMP 3
UUT start date/time
25 | P a g e
Measured voltage within
30 min interval Measured voltage within
60 min interval Measured voltage within
120 min interval Measured voltage within
26 | P a g e
Measured Current at Start of Test:
20Amps +/-.5% (19.9-20.1) pass/fail
Measured Voltage at Start of Test:
15V nominal pass/fail Life Test Start Date/Time:
Life Test End Date/Time:
Accumulated Hours on UUT:
500Hour Min. pass/fail Measured Current at End of Test:
20Amps +/-.5% (19.9-20.1) pass/fail Measured Voltage at End of Test:
Cannot measure greater than 6% pass/fail Measured value at start of test.
6.3 Measured Max. Candela after Lite
Test:
Candela measurement cannot fall
27 | P a g e
Measured Current:___________ 20Amps +/-.5%(19.9-20.1)
4.9 4.0°up Vertical Reading 16,000 Candela Min.
Actual Measured___________ pass/fail
4.4 Max Candela Measurement
48,000 Max Candela allowed
Actual Measured___________ pass/fail
4.6 3.5°down 13.5°left Reading 7,000 Candela Min.
Actual
Measured___________ pass/fail
4.8 3.5° down,13.5°right Reading 7,000 Candela Min.
Actual Measured___________ pass/fail
28 | P a g e
Pass/F
13.0 Low Temperature Test
Date performed:
29 | P a g e
Recorded measurement and test results
Pass/Fail
16.0 Low Pressure (Altitude Test)
Date performed:
Recorded measurement and test results Pass/Fail
17.0 Salt Fog Test
Date performed:
Recorded measurement and test results
30 | P a g e
E-2408b section 3.5.8.
31 | P a g e
LAMP 4
UUT start date/time
32 | P a g e
Measured voltage within
30 min interval Measured voltage within
60 min interval Measured voltage within
120 min interval Measured voltage within
33 | P a g e
Measured Current at Start of Test:
20Amps +/-.5% (19.9-20.1) pass/fail
Measured Voltage at Start of Test:
15V nominal pass/fail Life Test Start Date/Time:
Life Test End Date/Time:
Accumulated Hours on UUT:
500Hour Min. pass/fail Measured Current at End of Test:
20Amps +/-.5% (19.9-20.1) pass/fail Measured Voltage at End of Test:
Cannot measure greater than 6% pass/fail Measured value at start of test.
6.3 Measured Max. Candela after Lite
Test:
Candela measurement cannot fall
34 | P a g e
Measured Current:___________ 20Amps +/-.5%(19.9-20.1)
4.9 4.0°up Vertical Reading 16,000 Candela Min.
Actual Measured___________ pass/fail
4.4 Max Candela Measurement
48,000 Max Candela allowed
Actual Measured___________ pass/fail
4.6 3.5°down 13.5°left Reading 7,000 Candela Min.
Actual
Measured___________ pass/fail
4.8 3.5° down,13.5°right Reading 7,000 Candela Min.
Actual Measured___________ pass/fail
35 | P a g e
13.0 Low Temperature Test
36 | P a g e
Recorded measurement and test results
Pass/Fail
16.0 Low Pressure (Altitude Test)
Date performed:
Recorded measurement and test results Pass/Fail
17.0 Salt Fog Test
Date performed:
Recorded measurement and test results
37 | P a g e
E-2408b section 3.5.8.
38 | P a g e
LAMP 5 -
UUT start date/time
39 | P a g e
Measured voltage within
30 min interval Measured voltage within
60 min interval Measured voltage within
120 min interval Measured voltage within
40 | P a g e
Measured Current at Start of Test:
20Amps +/-.5% (19.9-20.1) pass/fail
Measured Voltage at Start of Test:
15V nominal pass/fail Life Test Start Date/Time:
Life Test End Date/Time:
Accumulated Hours on UUT:
500Hour Min. pass/fail Measured Current at End of Test:
20Amps +/-.5% (19.9-20.1) pass/fail Measured Voltage at End of Test:
Cannot measure greater than 6% pass/fail Measured value at start of test.
6.3 Measured Max. Candela after Lite
Test:
Candela measurement cannot fall
41 | P a g e
Measured Current:___________ 20Amps +/-.5%(19.9-20.1)
4.9 4.0°up Vertical Reading 16,000 Candela Min.
Actual Measured___________ pass/fail
4.4 Max Candela Measurement
48,000 Max Candela allowed
Actual Measured___________ pass/fail
4.6 3.5°down 13.5°left Reading 7,000 Candela Min.
Actual
Measured___________ pass/fail
4.8 3.5° down,13.5°right Reading 7,000 Candela Min.
Actual Measured___________ pass/fail
42 | P a g e
13.0 Low Temperature Test
Date performed:
43 | P a g e
Recorded measurement and test results
Pass/Fail
16.0 Low Pressure (Altitude Test)
Date performed:
Recorded measurement and test results Pass/Fail
17.0 Salt Fog Test
Date performed:
Recorded measurement and test results
44 | P a g e
E-2408b section 3.5.8.