This document contains specifications for a federal construction contract along with details of the related solicitation opportunity. The contract requires asphalt paving, slide repair, curb and gutter installation, sidewalk construction, underdrain installation, ditch reconditioning, and signage and striping work along 4 miles of the Camas Road in Glacier National Park, Montana. Detectable warning panels, tape, and a prefabricated double-vaulted concrete restroom facility are also specified to meet accessibility and environmental requirements. The solicitation was issued by the Department of Transportation Federal Highway Administration for the MT NPS GLAC 11(3) Camas Road project.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G-10 DIVISION 700
Special Contract Requirements Project: MT NPS GLAC 11(3), Camas Road Slumps and Resurface Remaining 4 Miles
Section 725. — MISCELLANEOUS MATERIAL
11/12/20– FP-14
725.18 725.19 Detectable Warning Panels. (Added Subsection):
Provide ADA compliant truncated dome detectable warning panels in a color as approved by the CO. Panels must meet the following requirements:
(a) Slip Resistance – ASTM C1028;
(b) Impact Resistance – ASTM D256;
(c) Compression Strength – ASTM D695;
(d) Flexural Strength – ASTM D790;
(e) Tensile Strength ⅛ inch – ASTM D638; and
(f) UL Flammability – UL 94 V-0.
725.19 725.20 Detectable Warning Tape. (Added Subsection).
Furnish detectable warning tape consisting of a nominal 4.5 mil overall thickness, with a solid aluminum foil core. The imprinted warning message is “Buried” to prevent ink rub-off, and is impervious to acids, alkalis and other destructive elements found in soil. The imprint is as such that it allows for total reflectivity. Provide tape that meets the following:
(a) Material: 4.5 Mil Detectable, 2-inch, 3-inch or 6-inch wide;
(b) Test Procedure: ASTM-D-882, Method A;
(c) Tensile Strength (Transverse) 5530 psi;
(d) Tensile Strength (Longitudinal) 4544 psi;
(e) Roll Weight - (3-inches x 1000 feet) ± 7.5 pounds;
(f) Roll Weight - (6-inches x 1000 feet) ± 15 pounds; and
(g) Legend: Caution Buried Utility Line Below.
725.20 725.21 Vault Toilet. (Added Subsection).
Furnish pre-engineered, precast, reinforced concrete, double vaulted waterless restroom facility(s) that are designed to last for 20 years; and architectural features that match the surrounding environment within Glacier National Park.
CXT Concrete building, DOUBLE CASCADIAN BUILDING STYLE is an acceptable product.
Revised by Amendment A001
File details come from the government source that posted it. Updated .