657-23-113JB - Construction Drawings - 8 of 14 - FP.pdf
PDF 562 KB Posted
- Attached to
- Z1DA--Create Code Compliant Research Laboratory Space in Building 1, 657-23-113JB Federal contract opportunity
- Solicitation number
- 36C25524R0053
About this file
This document is a set of construction drawings for the renovation of a research laboratory space in Building 1 at the Saint Louis VA Health Care System, as part of federal contract opportunity 36C25524R0053.
The drawings provide details on the fire protection system modifications required, including removing and relocating sprinkler heads, raising existing piping sections, and adding new branch lines and heads to provide adequate coverage for the laboratory space. The work must comply with NFPA-13 requirements for an Ordinary Hazard (Group 2) occupancy. The fire protection contractor is responsible for obtaining flow test data, preparing hydraulic calculations, and coordinating any system shutdowns with the VA. The drawings also include notes on seismic bracing requirements for the sprinkler piping.
View the file
Other files for this federal contract opportunity
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LAB
3C17OFFICE
3C18
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
01-18-2024
CONSTRUCTION DOCUMENTS
FCA - Create Code Compliant Research Laboratory Space in Building 1
657-23-113JB
Saint Louis VA Health Care System 1 Jefferson Barracks
Saint Louis, MO 63125
DEH DAE 44
100% SPRINKLERED
LAB 2C19 AND LAB 3C17 FIRE
PROTECTION PLANS
DEMOLITION NOTES#
KEYED NOTES#
GENERAL NOTES
1. REMOVE SECTION OF 1" SPRINKLER PIPE AND TWO EXISTING HEADS.
SECTION TO BE RAISED APPROXIMATELY 8".
2. REMOVE SECTION OF 1" SPRINKLER PIPE AND ONE EXISTING HEAD.
SECTION TO BE RAISED APPROXIMATELY 12".
3. REMOVE EXISTING HEAD BRANCH AND HEAD AND EXTEND 1" PIPE
TO NEW HEAD LOCATION.
4. EXISTING DRAIN VALVE.
1. EVERYTHING IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED.
1. NEW 1" BRANCH AND NEW HEAD.
2. NEW RAISED SECTION OF EXISTING PIPING.
3. CONNECT NEW 3/4" FP PIPE TO GAS CABINET HOOD, ITEM #G10.
EXIST. 1" FP
EXIST. 1" FP
EXIST. 1" FP
EXIST. 1" FP
EXIST. 1" FP
EXIST. 1" FP
EXIST. 2" FP
SPRINKLER HEAD LEGEND
SEMI-RECESSED HEAD, CHROME WITH ESCUTCHEON. CENTER HEAD IN TILE.
EXIST. 1" FP
EXIST. 2" FP
SPRINKLER HEAD LOCATION DETAIL F
SP0
A. ALL PIPING 2-1/2 IN. NOMINAL DIAMETER AND LARGER MUST BE BRACED.
B. TRANSVERSE AND VERTICAL BRACING SHALL OCCUR AT 40 FT.
INTERVALS (MAX) AND LONGITUDINAL BRACING AT 80 FT. INTERVALS
(MAX).
C. BRACING IS NOT REQUIRED FOR PIPING SUSPENDED BY HANGERS 12 IN.
OR LESS IN LENGTH AS MEASURED FROM THE TOP OF THE PIPE TO THE
BOTTOM OF THE SUPPORT WHERE THE HANGER IS ATTACHED.
1. FIRE PROTECTION CONTRACTOR SHALL DESIGN AND INSTALL THE REQUIRED NEW
SYSTEM OR MODIFICATIONS TO THE EXISTING HYDRAULICALLY CALCULATED WET
PIPE SPRINKLER SYSTEM FOR THE LABORATORY SPACE INDICATED HEREIN THESE
DOCUMENTS. THE SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE
WITH THE REQUIREMENTS OF NFPA-13 FOR ORDINARY HAZARD (GROUP 2)
OCCUPANCY, PROVIDING A SPRINKLER DENSITY OF .20 GPM SQFT OVER THE MOST
REMOTE 1500 SQ.FT. SPRINKLER HEAD SPACING SHALL NOT EXCEED 130 SQ.FT. PER
HEAD.
2. FIRE PROTECTION CONTRACTOR SHALL PREPARE AND SUBMIT SPRINKLER SHOP
DRAWINGS AND HYDRAULIC CALCULATIONS TO THE A/E AND VA COR.
3. FIRE PROTECTION SYSTEMS ARE TO BE MAINTAINED IN ACCORDANCE WITH
ORIGINAL INSTALLATION STANDARDS. REQUIRED FIRE PROTECTION SYSTEM SHALL
BE MODIFIED AS NECESSARY TO MAINTAIN PROTECTION WHENEVER BUILDING IS
ALTERED.
4. FOR EXISTING SYSTEM REMOVE OR RELOCATE EXISTING SPRINKLER HEADS AND
FURNISH AND INSTALL NEW AS PER NFPA-13 RECOMMENDATIONS, TO PROVIDE
ADEQUATE COVERAGE OF THE ENTIRE SPACE.
3. THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING FLOW
TEST DATA AND PREPARING HYDRAULIC CALCULATIONS.
4. NEW SPRINKLER HEADS SHALL BE APPROVED STANDARD TYPES, PENDENT AND
UPRIGHT, AND DESIGNED FOR ORDINARY HAZARD COVERAGE. CHROME PLATED
"TYCO", "GRINNELL", "VIKING", "STAR" OR EQUAL. SEE PLANS FOR SPRINKLER HEAD
TYPES.
5. ALL SPRINKLER WORK SHALL COMPLY WITH ALL NFPA-13 RECOMMENDATIONS, AND
SHALL BE PERFORMED IN ACCORDANCE WITH THE RULES AND REGULATIONS OF
THE VA, LOCAL FIRE RATING ORGANIZATION, FIRE AND/OR BUILDING
DEPARTMENTS AND ALL AUTHORITIES IN JURISDICTION.
6. FIRE PROTECTION CONTRACTOR SHALL ARRANGE FOR ANY SHUTDOWNS OF THE
EXISITING SYSTEM WITH THE VA COR AND VA SHOPS, AND SHALL SECURE IN
WRITING PRIOR TO SHUTDOWN, APPROVALS FROM SAME. ADDITIONALLY, THE FIRE
PROTECTION CONTRACTOR SHALL PAY FOR ANY LABOR, MATERIALS, AND FEES
NECESSARY FOR SHUTDOWN.
7. IN THE EVENT OF THE FIRE PROTECTION SYSTEM BEING "OUT OF SERVICE", THE FIRE
DEPARTMENT & LOCAL CODE OFFICIALS SHALL BE NOTIFIED IMMEDIATELY, AND IF
REQUIRED BY THE VA AND/OR CODE OFFICIAL, SAID BUILDING TO BE EVACUATED
OR PROVIDED WITH AN APPROVED FIRE WATCH SYSTEM WILL BE PROVIDED FOR
ALL UNPROTECTED OCCUPANTS UNTIL SYSTEM IS RETURNED TO SERVICE.
8. WHEN UTILIZED, FIRE WATCHES SHALL BE PROVIDED W/ MIN. OF ONE APPROVED
MEANS OF NOTIFICATION OF THE FIRE DEPT. THE ONLY DUTY OF THE FIRE WATCH IS
TO PERFORM CONSTANT PATROLS OF THE PREMISES AND KEEP WATCH FOR FIRES.
9. FIRE PROTECTION CONTRACTOR SHALL CAREFULLY EXAMINE ALL EXISTING
SPRINKLER SYSTEM PIPING AND COMPONENTS, AND SHALL REPAIR OR REPLACE ANY
LEAKING OF DEFECTIVE PIPING OR COMPONENTS, FOR SPACE BEING PROTECTED.
10. SPRINKLER PIPE MATERIAL AND INSTALLATION SHALL MATCH EXISTING. FIRE
PROTECTION CONTRACTOR SHALL PROVIDE ALL REQUIRED TEST AND DRAIN
CONNECTIONS, WHETHER OR NOT THEY ARE INDICATED HEREON THESE PLANS.
FIRE PROTECTION CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY
ALARM INITIATING DEVICES AND SUPERVISORY DEVICES, AND SHALL COORDINATE
THE ELECTRICAL REQUIREMENTS FOR THEM WITH THE E.C. AND/OR FIRE ALARM
CONTRACTOR FOR THEIR CONNECTION TO THE FIRE ALARM SYSTEM.
11. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGES TO ANY
PORTION OF THE EXISTING SPRINKLER SYSTEM ON ANY PORTION OF THE BUILDING
INCURRED BY HIM DURING CONSTRUCTION.
SPRINKLER SYSTEM NOTES
1-FP-101
G10
NEW 3/4" FP
EXIST. FP MAIN
NEW 1" FP
NEW 3/4" FP
EXIST. 1" FP
EXIST. 2" FP
SEISMIC BRACING NOTES
AutoCAD SHX Text %%ULab 2C19 Fire Protection - Demolition
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text %%ULab 3C17 Fire Protection - Demolition
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text %%ULab 3C17 Fire Protection Plan
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text %%ULab 2C19 Fire Protection Plan
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text 062-073724
AutoCAD SHX Text
REGISTERED
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text R
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
PENDENT TYPE SPK. HD. LOCATION
AutoCAD SHX Text
2' X 4' ACOUSTIC CEILING TILE
AutoCAD SHX Text
PENDENT TYPE SPK. HD. LOCATION
AutoCAD SHX Text
2' X 4' ACOUSTIC CEILING TILE
AutoCAD SHX Text
PENDENT TYPE SPK. HD. LOCATION
AutoCAD SHX Text
2' X 2' ACOUSTIC CEILING TILE
AutoCAD SHX Text
PENDENT TYPE SPK. HD. LOCATION
AutoCAD SHX Text
PARTIAL ACOUSTIC CEILING TILE
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text C
AutoCAD SHX Text L
File details come from the government source that posted it. Updated .