583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part7.pdf

PDF 4 MB Posted

Attached to
Z1DA--Renovate Nuclear Med 583-20-102 (VA-21-00037478)
Solicitation number
36C25021B0036
Issued by

About this file

This document package includes architectural plans and drawings for a federal construction contract opportunity to relocate nuclear medicine services. Key details include renovating and reconfiguring existing spaces on multiple floors to accommodate new PET/CT and nuclear medicine scanner equipment, support spaces including control rooms, dosing rooms, waiting areas, and staff and patient facilities. The project also involves installing new mechanical, electrical and plumbing systems to support the medical equipment. The solicitation number is listed as 36C25021B0036 with a project title to renovate nuclear medicine services at the Richard L. Roudebush VA Medical Facility in Indianapolis, Indiana. The contract is through the Department of Veterans Affairs Veterans Health Administration.

View the file

Other files

File Type Posted
Amendment A00006.docx DOCX document
Amendment A00006 RFI Responses.docx DOCX document
Amendment 36C25021B0036 A00005.pdf PDF
A00004- Corrected Statement of Work.pdf PDF
Amendment 36C25021B0036 A00004.pdf PDF
A00004 - RFI Responses.docx DOCX document
A0004 - 08 71 00 - Door Hardware.pdf PDF
A00004 - 10 25 13 - Patient Bed Service Walls.pdf PDF
A00004 - Door Schedule.pdf PDF
Amendment 36C25021B0036 A00003.pdf PDF
Amendment A00002.pdf PDF
Site Visit Sign-in Sheet.pdf PDF
A0001 - RFI 1 ShieldingReportComplete.pdf PDF
A0001 - RFI 2- GC101.pdf PDF
A0001 - RFI Responses.docx DOCX document
Amendment A0001.docx DOCX document
A0001 - RFI 4- Door Schedule.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part1.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part12.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part18.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part10.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part5.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part23.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part22.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part14.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part11.pdf PDF
Specifications.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part21.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part13.pdf PDF
Wage Determination.txt TXT text file
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part15.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part16.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part4.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part9.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part20.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part5.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part8.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part10.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part7.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part12.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part6.pdf PDF
36C25021B0036 Solicitation Document.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part11.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part14.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part16.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part24.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-2_Part9.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part1.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part2.pdf PDF
583-20-102 Relocate Nuclear Medicine Drawing SetPart-1_01_Part3.pdf PDF
Show 40 more

Latest 50 of 66 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

270 SF

A-B005

COMBINED PET

CONTROL ROOM

NMCR1

316 SF

A-B007

HOT LAB

NMRP1

114 SF

A-B008

DOSE ADMIN. ROOM

NMIR1

114 SF

A-B009

DOSE ADMIN. ROOM

NMIR1

145 SF

A-B010

DOSE ADMIN. ROOM

NMIR1

520 SF

A-B013

READING &

CONSULTATION

XVC01

106 SF

A-B012

DOSE ADMIN. ROOM

NMIR1

235 SF

A-B014

EQUIP CALIBRATION

NMDC1

92 SF

A-B01

SOILED UTILITY

USCL1

65 SF

A-B026

TOILET, STAFF

TNPG1

59 SF

A-B027

TOILET, STAFF

TNPG1

64 SF

A-B028

PET TOILET,

PATIENT

TPG01

452 SF

A-B029a

NM SCAN 1

NMGS1

338 SF

A-B029

NM CONTROL RM

NMCR1

69 SF

A-B016

NM TOILET, PATIENT

TPG01

60 SF

A-B017

NM TOILET, PATIENT

TPG01

130 SF

A-B018

SUPERVISOR

OFFICE

OFA09

760 SF

A-B020

OUTPATIENT

WAITING

WTG06

1190 SF

CORRIDOR

CB-9

717 SF

AUDITORIUM

CORRIDOR

CB-10

A

457 3.5

B

C

D

E

F

2.58910

CLR

7'-2"

17 SF

A-B025

ELEC ROOM

CLR

9'-8 1/2"

'-7

/8

6'

-2

/8

'-4

/8

C

LR

8' -0

7'

-1

3/ 8"

CLR

8'-0"

'-9

/2

'-1

3/ 4"

D.5

C

LR

5' -0

'-9

/8

9'

-0

2'-2" 8'-5 3/8" 28'-11 1/8"

CLR

8'-0"

8'

/8

112 SF

A-B004a

PET EQUIPMENT

ROOM

XMRC2

464 SF

A-B004

PET / CT 2

NMSS1

CLR

8' - 0"

150 SF

A-B002

DOSE ADMIN. ROOM

NMRI1

150 SF

A-B003

DOSE ADMIN. ROOM

NMRI1

126 SF

A-B006a

PET EQUIPMENT

ROOM

XMRC2

136 SF

A-B024

PATIENT INTERVIEW

ROOM

PAIA1

457 SF

A-B023

CARDIAC STRESS

TESTING

OPPE2

202 SF

A-B021

INPATIENT HOLDING

ORPP1

123 SF

A-B022

THYROID UPTAKE

NMUR1

32 SF

C-5A

ALCOVE

SB001

150 SF

A-B030

DIGI ROD, MOBILE

EQUIPMENT

XRM01

136 SF

A-B031

CLEAN SUPPLY

UCCL1

456 SF

A-B029b

NM SCAN 2

NMGS1

8 SF

CLOSET

C-6a

CLR

5' - 11"

/2

7'

/8

111213

'-0

/8

9'

-9

17'-1 3/8" 21'-1 5/8" 9'-8 1/2"

'-1

/4

8'

-1

7/ 8"

CLR

8'-0"

C

LR

3' -6

9'-2 5/8" 25'-8 3/4"

CLR

8'-0" 10 3/8"

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

S3A.1F

S3A.1F

S3A.1F

S3A.Gi

S6A.Gi

S6A.GiL

S6A.GiL

S6A.GiL

S6A.GiL

S6A.GiL S6A.GiL

S6A.GiL

S6A.GiL

S3A.Gi

S6A.GiL

S6A.GiL

S6A.GiL

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

215 SF

A-B019

MSA / SCHEDULING

RCP02

S6A.GiL

S6A.GiL

S3B.SP C

LR

8' -0

S3A.Gi

S3A.Gi

11'-9 1/4" 11'-9 1/4" 10'-2 7/8"

3' -1

1/

4" 3'

-0

/8

CLR

8'-0"

F0D.G

1'-6"

1 1

CLR

6'-9 1/2"

S3A.Gi

488 SF

A-B006

PET / CT 1

NMSS1

13'-9 7/8" 9'-8 3/4"

8' -9

/8

10'-3 1/8"

19'-4 5/8"

16'-0 3/8"

R .O

4' -4

/2

4'-8 3/8"

R.O.

4'-4 1/2"

2'-6"

R.O.

6'-0" 6'-10"

R.O.

4'-4 1/2"

401 SF

A-B015

STAFF LOUNGE

SL001

BUILDING EXIT

STAIR

#9B

PUBLIC

TOILET,

MEN'S

A-B156

PUBLIC

TOILET,

WOMEN'S

A-B157

ELEV.

P-15

ELEV.

P-16

ELEV.

P-14

ELEV.

P-13

ELEV.

S-11

ELEV.

S-12

FUTURE

S-13

LOBBY

CB-11

LOBBY

CB-10

UP

ELEC.

A-B153

MECHANICAL

ROOM

A-B150

UP

CORRIDOR

CB-7

4' -4

/8

'-6

/4

31 SF

1A

PATIENT

EDUCATION KIOSK

CLSC1

74 SF

3A

HOLDING BAY 1

ORPP1

74 SF

3B

HOLDING BAY 2

ORPP1

102 SF

RADIOACTIVE

WASTE STORAGE

A-B007a

S6A.GiL

F3D.G

S6A.GiL

16'-10 3/8"

71 SF

3C

HOLDING BAY 3

ORPP1

6' -8

/4

1' -7

/4

R .O

4' -0

6"

5'-11 5/8"

1' -0

/8

3' -6

3'

-0

R .O

6' -0

6'

-6

/8

R .O

6' -0

3'

-1

3' -6

3/

4"

11'-7 1/2" 11'-7 1/2"

3' -0

1'-1 1/8"

5'-4 7/8" 13'-7 1/2"

10 1/2"

C

LR

3' -6

'-7

/2

AI203

AI203

S3A.G

3' -0

S6A.GiL

S6A.GiL

S6A.GiL

S6A.GiL

S6A.GiL

7'-10 1/4" 13'-3 3/8"

4' -4

/8

S3A.G

S3A.Gi

S3A.Gi

S3A.Gi

S3A.Gi

F3D.G

S6A.GiL

S6A.GiL

S3A.G S3A.G

S6A.Gi

16'-11 3/8"

S3A.Gi

S3A.Gi

F6A.GiL

S6A.GiL

'-6

/8

9'

-0

21'-2"

2'-2 1/2"

3' -0

/4

9'

-0

21'-2"

2'-3 1/2"

2092 SF

AUDITORIUM

A-B066

1741 SF

OFFICE

A-B040

153 SF

QCIS

A-B039

234 SF

TEAM ROOM

A-B038

105 SF

PATIENT SAFETY

MANAGER

A-B043

270 SF

ASSISTANT LOG

A-B041152 SF

CHIEF LOG.

A-B042

84 SF

NOURISHMENT

A-B047

68 SF

INFECTION

CONTROL MANAGER

A-B046

118 SF

CHIEF QUALITY

MANAGEMENT

A-B045

76 SF

RISK MANAGER

A-B044

EQ EQ

EQ EQ

EQ EQ

1 1

MECHANICAL ROOM

A-B048

MIN

3'-0"

NEW PAD TO BE 6" LARGER THAN NEW AHU

VERIFY IN FIELD

N E

W P

A D

T O

B E

LA

R

G E

R T

H A

N N

E W

A H

U

V E

R

IF

Y

IN

F

IE

LD

324 SF

EAST CORRIDOR

C-3

897 SF

NORTH CORRIDOR

C-2

413 SF

WEST CORRIDOR

C-5

509 SF

SOUTH CORRIDOR

C-4

238 SF

STAFF ENTRANCE

CORRIDOR

C-1

N

KEY PLAN

PROJECT

LOCATION

DIMENSION FLOOR PLAN GENERAL NOTES

DIMENSION FLOOR PLAN NOTES

1. ALIGN FINISH FACE OF WALL WITH OUTER FINISH FACE OF EXISTING WALL.

PROVIDE SEAMLESS TRANSITION AND NEW FINISH. ALIGN FINISH FACE OF

WALL, BOTH SIDES WHERE APPLICABLE.

2. INFILL EXISTING WALL WITH WALL OF SAME HEIGHT, WIDTH, FIRE OR SMOKE

RATING, ETC. ALIGN FINISH FACE OF NEW WALL WITH EXISTING, BOTH

SIDES.PROVIDE SMOOTH TRANSITION. PREP FOR NEW FINISHES.

3. LINE OF NEW SLAB ON GRADE.

4. 1/16" LEAD WALL / DOOR SHIELDING, REFER TO WALL TYPE

5. 1/8" LEAD WALL / DOOR SHIELDING, REFER TO WALL TYPE

6. 1/4" LEAD WALL SHIELDING, REFER TO WALL TYPE

7. 1/2" LEAD WALL SHIELDING, REFER TO WALL TYPE

8. 1/32" LEAD WALL SHIELDING, REFER TO WALL TYPE

9. RAISED 6" CONCRETE PAD, REFER TO MECHANICAL DRAWINGS.

CONTRACTOR TO VERIFY ALL EXISTING AND NEW DIMENSIONS.

10. PET/CT EQUIPMENT INSTALLED BY VENDOR - REFER TO SD300 SERIES

SHEETS FOR VENDOR INFORMATION.

11. PET/CT EQUIPMENT INSTALLED BY VENDOR - REFER TO SD400 SERIES

SHEETS FOR VENDOR INFORMATION.

12. NUC MED SCANNER EQUIPMENT INSTALLED BY VENDOR - REFER TO SD100

SERIES SHEETS FOR VENDOR INFORMATION.

13. NUC MED SCANNER EQUIPMENT RELOCATED AND INSTALLED BY VENDOR -

REFER TO SD200 SERIES SHEETS FOR VENDOR INFORMATION.

A. ALL DIMENSIONS SHOWN ARE TO FACE OF WALL FRAMING/ MASONRY

UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATES AS "CLR" OR

"CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF

FINISH.

B. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND

REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.

C. CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS

AFFECTED BY DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.

D. PROVIDE CONTROL JOINT ON CONTINUOUS GYPSUM BOARD WALLS

GREATER THAN 30' LONG.

E. PROVIDE CONTROL JOINTS AT CORNERS OF DOORS OR WINDOWS.

F. WHERE NO DIMENSION IS INDICATED, FINISH DOORS 6" FROM EDGE OF

STUD FRAMING AT CORNERS UNLESS OTHERWISE NOTED.

G. ALL NEW PARTITIONS ARE WALL TYPE S3A.G UNLESS NOTED OTHERWISE.

REFER TO WALL TYPE GENERAL NOTES AE002 FOR WALL BOARD MATERIAL.

H. NON-RATED WALL CONSTRUCTION THAT FORMS CHASE AREAS DOES NOT

REQUIRE GYPSUM BOARD INSTALLATION ON INTERIOR OF CHASE WALL.

REFER TO WALL TYPES F0D.G, F1D.G, AND F3D.G.

I. COLUMN DIMENSIONS ARE FOR REFERENCE AND SHALL BE VERIFIED IN THE

FIELD.

J. REFER TO ENLARGED FLOOR PLANS FOR ADDITIONAL DIMENSIONS FOR

TOILET AND BATH ROOMS.

K. DIMENSIONS INDICATED AS 'VIF' MAY INCREASE OR DECREASE TO MATCH

FIELD CONDITIONS. ALL OTHER DIMENSIONS WITHIN THE DIMENSION STRING

MUST BE MAINTAINED.

L. PROVIDE BLOCKING AND STRAPPING FOR WALL MOUNTED CASEWORK,

FURNITURE, AND ACCESSORIES. COORDINATE WITH FLOOR PLANS,

SCHEDULES, ELEVATIONS, AND ENGINEERING DRAWINGS FOR FULL SCOPE

OF WORK.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.0

N u c M e d v d c h ri s te n s e n M

N F

X

.r v t

/2

/2

:5

:2

A

M

AE101

LOWER LEVEL DIMENSION PLAN

GUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

HEAPY

1400 W. DOROTHY LANE

DAYTON, OH 45409

937.224.0861

RELOCATE NUCLEAR MEDICINE

SERVICES FOR CENTRALIZED

SERVICES

INDIANAPOLIS, IN

583-20-102

01/28/2021 JLG DMC

BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"AE101

1 DIMENSION PLAN

SPACE PLANNING SCHEDULE

ROOM

ROOM

NUMBER

ROOM

CODE SEPS SF ACTUAL SF

PATIENT EDUCATION KIOSK 1A CLSC1 30 SF 31 SF

HOLDING BAY 1 3A ORPP1 80 SF 74 SF

HOLDING BAY 2 3B ORPP1 80 SF 74 SF

HOLDING BAY 3 3C ORPP1 71 SF

SOILED UTILITY A-B01 USCL1 92 SF

DOSE ADMIN. ROOM A-B002 NMRI1 150 SF

DOSE ADMIN. ROOM A-B003 NMRI1 150 SF

PET / CT 2 A-B004 NMSS1 464 SF

PET EQUIPMENT ROOM A-B004a XMRC2 112 SF

COMBINED PET CONTROL ROOM A-B005 NMCR1 270 SF

PET / CT 1 A-B006 NMSS1 488 SF

PET EQUIPMENT ROOM A-B006a XMRC2 126 SF

HOT LAB A-B007 NMRP1 316 SF

RADIOACTIVE WASTE STORAGE A-B007a NMDC1 102 SF

DOSE ADMIN. ROOM A-B008 NMIR1 114 SF

DOSE ADMIN. ROOM A-B009 NMIR1 114 SF

DOSE ADMIN. ROOM A-B010 NMIR1 145 SF

DOSE ADMIN. ROOM A-B012 NMIR1 106 SF

READING & CONSULTATION A-B013 XVC01 520 SF

EQUIP CALIBRATION A-B014 NMDC1 235 SF

STAFF LOUNGE A-B015 SL001 401 SF

NM TOILET, PATIENT A-B016 TPG01 SS-4 UP TO 5'-0"

A.F.F.

69 SF

NM TOILET, PATIENT A-B017 TPG01 SS-4 UP TO 5'-0"

A.F.F.

60 SF

SUPERVISOR OFFICE A-B018 OFA09 130 SF

MSA / SCHEDULING A-B019 RCP02 215 SF

OUTPATIENT WAITING A-B020 WTG06 760 SF

INPATIENT HOLDING A-B021 ORPP1 202 SF

THYROID UPTAKE A-B022 NMUR1 123 SF

CARDIAC STRESS TESTING A-B023 OPPE2 457 SF

PATIENT INTERVIEW ROOM A-B024 PAIA1 136 SF

ELEC ROOM A-B025 -- 17 SF

TOILET, STAFF A-B026 TNPG1 SS-4 UP TO 5'-0"

A.F.F.

65 SF

TOILET, STAFF A-B027 TNPG1 SS-4 UP TO 5'-0"

A.F.F.

59 SF

PET TOILET, PATIENT A-B028 TPG01 SS-4 UP TO 5'-0"

A.F.F.

64 SF

NM CONTROL RM A-B029 NMCR1 338 SF

NM SCAN 1 A-B029a NMGS1 452 SF

NM SCAN 2 A-B029b NMGS1 456 SF

DIGI ROD, MOBILE EQUIPMENT A-B030 XRM01 150 SF

CLEAN SUPPLY A-B031 UCCL1 136 SF

TEAM ROOM A-B038 234 SF

QCIS A-B039 153 SF

OFFICE A-B040 1741 SF

ASSISTANT LOG A-B041 270 SF

CHIEF LOG. A-B042 152 SF

PATIENT SAFETY MANAGER A-B043 105 SF

RISK MANAGER A-B044 76 SF

CHIEF QUALITY MANAGEMENT A-B045 118 SF

INFECTION CONTROL MANAGER A-B046 68 SF

NOURISHMENT A-B047 84 SF

MECHANICAL ROOM A-B048 6264 SF

AUDITORIUM A-B066 2092 SF

STAFF ENTRANCE CORRIDOR C-1 238 SF

NORTH CORRIDOR C-2 -- 897 SF

EAST CORRIDOR C-3 324 SF

SOUTH CORRIDOR C-4 509 SF

WEST CORRIDOR C-5 413 SF

ALCOVE C-5A SB001 32 SF

CORRIDOR C-6 156 SF

CLOSET C-6a -- 8 SF

CORRIDOR CB-9 -- 1190 SF

AUDITORIUM CORRIDOR CB-10 -- 717 SF

N

Revisions: Date:

NOTE:

REFER TO SHEETS SD100-SD409 FOR PET/CT AND NUC MED

SCANNER EQUIPMENT VENDOR INFORMATION.

UP

ARCHITECTURAL GENERAL NOTES

ARCHITECTURAL PLAN NOTES #

A. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION

AND ELECTRICAL FOR COORDINATION ITEMS. COORDINATE AS REQUIRED

INCLUDING NECESSARY FRAMING, BLOCKING, ETC.

B. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND

REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.

C. PATCH EXISTING WALLS WHERE NEW WALLS MEET.

D. ALL HANDRAILS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE

WITH ALL REQUIREMENTS OF ADA/ABA GUIDELINES AND ALL CODES AND

REGULATIONS HAVING JURISDICTION, THE MOST STRINGENT SHALL

PREVAIL.

E. PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ADA/ABA

REQUIREMENTS.

F. WHERE NO DIMENSION IS INDICATED, FINISH DOORS 6" FROM EDGE OF

STUD FRAMING AT CORNERS UNLESS OTHERWISE NOTED.

G. REFER TO SHEET QH102 FOR EQUIPMENT SCHEDULE AND INFORMATION.

H. REFER TO SHEET AI201 FOR ACCESSORIES TO BE PROVIDED IN THE

TOILET/BATH ROOMS AND AT THE HAND LAVATORIES.

I. LEVEL AND INFILL FLOOR SLAB TO RECEIVE NEW FLOORING. REFER TO

SPECIFICATIONS AND FLOORING MANUFACTURE'S TOLERANCES FOR

ADDITIONAL INFORMATION.

J. PROVIDE METAL PLATE ON UNDERSIDE OF FLOOR SLAB WHERE CONCRETE

INFILL IS REQUIRED AND CHIP AWAY CONCRETE AT FLOOR LEVEL TO

CREATE A SLOPED OPENING/LIP TO PATCH PENETRATIONS AND PREVENT

CONCRETE INFILL CORE FROM FALLING THROUGH OPENING TO FLOOR

BELOW.

1. OVERHEAD CURTAIN AND TRACK. REFER TO REFLECTED CEILING PLAN FOR

MORE INFORMATION.

2. EXISTING CHASE TO REMAIN. PROTECT DURING DEMOLITION AND

CONSTRUCTION PHASES. IF ACCESS IS REQUIRED DURING CONSTRUCTION,

MAINTAIN FIRE RATING AND FINISH AS REQUIRED.

3. EXISTING 3'-6" DIA. X 3'-0" DEEP SLAB RECESS FOR LIFT PUMP TO REMAIN.

4. SHADED AREA INDICATES AREA OF NEW REINFORCED SLAB ON GRADE.

5. LOCATION FOR CREDENTIAL READER. REFER TO DOOR SCHEDULE AND

ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION.

6. LOCATION FOR AUTOMATIC DOOR OPERATOR DOOR ACTUATOR. REFER TO

DOOR SCHEDULE AND ENGINEERING DRAWINGS FOR ADDITIONAL

INFORMATION.

7. EXISTING RAISED CONCRETE PAD w/ ADDITION. REFER TO MECHANCIAL

DRAWINGS FOR ADDITIONAL INFORMATION. CONTRACTOR TO VERIFY ALL

EXISTING AND NEW DIMENSIONS.

8. PET/CT EQUIPMENT INSTALLED BY VENDOR - REFER TO SD300 SERIES

SHEETS FOR VENDOR INFORMATION.

9. PET/CT EQUIPMENT INSTALLED BY VENDOR - REFER TO SD400 SERIES

SHEETS FOR VENDOR INFORMATION.

10. NUC MED SCANNER EQUIPMENT INSTALLED BY VENDOR - REFER TO SD100

SERIES SHEETS FOR VENDOR INFORMATION.

11. NUC MED SCANNER EQUIPMENT RELOCATED AND INSTALLED BY VENDOR -

REFER TO SD200 SERIES SHEETS FOR VENDOR INFORMATION.

A

457 3.5

B

C

D

E

F

2.58910

D.5

111213

COMBINED PET

CONTROL ROOM

A-B005

HOT LAB

A-B007

DOSE ADMIN. ROOM

A-B008

DOSE ADMIN. ROOM

A-B009

DOSE ADMIN. ROOM

A-B010

READING &

CONSULTATION

A-B013

DOSE ADMIN. ROOM

A-B012

EQUIP CALIBRATION

A-B014

SOILED UTILITY

A-B01

TOILET, STAFF

A-B026

TOILET, STAFF

A-B027

PET TOILET,

PATIENT

A-B028

NM SCAN 1

A-B029a

NM CONTROL RM

A-B029

NM TOILET, PATIENT

A-B016

NM TOILET, PATIENT

A-B017

SUPERVISOR

OFFICE

A-B018

OUTPATIENT

WAITING

A-B020

CORRIDOR

CB-9

AUDITORIUM

CORRIDOR

CB-10

ELEC ROOM

A-B025

CB-9

9A

A -B

0a

A -B

A-B025

A-B022

A -B

A-B029b

A-B026

A-B027

A -B

A-B006

A -B

A -B

A -B

A -B

9B

A-B016

A-B018

A-B017

A -B

0b

9C A-B029

W1

W2

W2

A-B023

A-B019

A-B029a

A-B012

A -B

A -B

A-B011

A -B

PET EQUIPMENT

ROOM

A-B004a

PET / CT 2

A-B004

6'

/8

8' - 0"

DOSE ADMIN. ROOM

A-B002

DOSE ADMIN. ROOM

A-B003

PET EQUIPMENT

ROOM

A-B006a

PATIENT INTERVIEW

ROOM

A-B024

CARDIAC STRESS

TESTING

A-B023

202 SF

INPATIENT HOLDING

A-B021

THYROID UPTAKE

A-B022

ALCOVE

DIGI ROD, MOBILE

EQUIPMENT

A-B030

CLEAN SUPPLY

A-B031

NM SCAN 2

A-B029b

A-B002

A-B003

A-B004

A -B

4b

CLOSET

C-6a

5' - 11"

9'

/2

/8

A -B

AE501

AE501

AE501

AOCR

C R

AOCR CR

CR

AO

AO

CR

AO

W2

2 5 5 6

6 5

CR

A-B029d

A-B029c

MSA / SCHEDULING

A-B019

AE501

A -B

4a

488 SF

PET / CT 1

A-B006

102 SF

RADIOACTIVE

WASTE STORAGE

A-B007a

401 SF

STAFF LOUNGE

A-B015

A-B007a

W2

HOLDING BAY 3

HOLDING BAY 1

HOLDING BAY 2

A-B006a

NORTH CORRIDOR

C-2

WEST CORRIDOR

C-5

EAST CORRIDOR

C-3

238 SF

STAFF ENTRANCE

CORRIDOR

C-1

A-B005a

AE502

AE502

AE502

AE502

AE502

AE502

AE502

AE502

A-B020

AE501

CORRIDOR

C-6

SOUTH CORRIDOR

C-4

AUDITORIUM

A-B066

OFFICE

A-B040

QCIS

A-B039

TEAM ROOM

A-B038

PATIENT SAFETY

MANAGER

A-B043

ASSISTANT LOG

A-B041

CHIEF LOG.

A-B042

NOURISHMENT

A-B047

INFECTION

CONTROL MANAGER

A-B046

CHIEF QUALITY

MANAGEMENT

A-B045

RISK MANAGER

A-B044

AE501

AE501

AE501

AE501

9' -0

21'-2"

21'-2"

9' -0

A -B

A-B029f

CR

AOCR

CR

AO

CR

AE501

AE501

NEW PAD TO BE 6" LARGER THAN NEW AHU

VERIFY IN FIELD

N E

W P

A D

T O

B E

LA

R

G E

R T

H A

N N

E W

A H

U

V E

R

IF

Y

IN

F

IE

LD

MECHANICAL ROOM

A-B048

MIN

3'-0"

N

KEY PLAN

PROJECT

LOCATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.0

N u c M e d v d c h ri s te n s e n M

N F

X

.r v t

/2

/2

:5

:2

A

M

AE102

LOWER LEVEL ARCHITECTURAL

PLANGUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

HEAPY

1400 W. DOROTHY LANE

DAYTON, OH 45409

937.224.0861

RELOCATE NUCLEAR MEDICINE

SERVICES FOR CENTRALIZED

SERVICES

INDIANAPOLIS, IN

583-20-102

01/28/2021 JLG PAE, II

BID DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"AE102

1 PLAN DETAIL

N

Revisions: Date:

1' - 8"

2'

10" DIA. STAINLESS

STEEL WELDED DUCT,

FIRE WRAPPED, SEE

MECHANICAL

20" x 26" INSIDE

CLEAR DIMENSION

MECHANICAL

CHASE, NON RATED,

SEE MECHANICAL

F3D.Gi

REFER TO OPENING THRU

SLAB DETAIL, 2/AE104 FOR

SLAB REINFORCING.

6'-0" MIN.

PROVIDE TEMPORARY BARRIERS AS

REQUIRED TO MEET ICRA RATING BY

STARC WALL SYSTEMS OR EQUAL 'LITE

WALL'. THIS AREA SHALL BE AVAILABLE

TO THE CONTRACTOR FOR 48 HRS MAX,

DAYS AND TIMES TO BE COORDINATED

WITH VA COR. SEE MECHANICAL FOR

SCOPE OF MECHANICAL WORK.PROVIDE TEMPORARY BARRIERS AS

REQUIRED TO MEET ICRA RATING

BY STARC WALL SYSTEMS OR

EQUAL 'LITE WALL'.

*REFER TO DRAWINGS AND

SPECIFICATIONS FOR OTHER INFECTION

CONTROL RELATED REQUIREMENTS IN

THIS AREA. COORDINATE CLOSELY WITH

VA COR AS THIS IS A 24 HR EMERGENCY

CARE SUITE.

6' -0

M

IN

LIBRARY

A-2009

MICROFORM

A-2014

CLERICAL

A-2015

OFFICE

A-2017

ROOM

A-2021

TRAINING

ROOM

A2022

SIMULATION

LAB

A2023

RUN EXHAUST DUCT ACROSS

ROOF, COORD. W/ MECHANICAL

DRAWINGS

RUN EXHAUST DUCT UP

WALL, COORD. W/

MECHANCIAL DRAWINGS

RUN EXHAUST DUCT UP THRU ROOF

SLAB, INSULATION, AND ROOFING,

SEE MECHANICAL DRAWINGS.

REFER TO OPENING THRU SLAB

DETAIL, 2/AE104 FOR SLAB

REINFORCING.

N

KEY PLAN

PROJECT

LOCATION

EXISTING ROOF DECK, CUT FOR NEW

PENETRATION AS REQUIRED, REFER TO

OPENING THRU SLAB DETAIL, 11/AE501 FOR

SLAB REINFORCING

EXISTING ROOF INSULATION, CUT FOR NEW

PENETRATION AS REQUIRED

NEW ROOFING MEMBRANE TO MATCH EXISTING

NEW .063" ALUMINUM COPING WITH KYNAR FINISH

NEW TREATED WOOD BLOCKING

NEW TREATED WOOD CANT

NEW EXHAUST DUCT

NEW DUCT PENETRATION CURB

CONCRETE

BEAM

C9X20 FRAME

DECK

OPENING

NOTE: COORDINATE OPENING SIZE WITH MECHANICAL

CONTRACTOR.

FOR OPENINGS

12" OR GREATER

1/2" PLATE. DRILL AND EPXOY W/ MIN 2 ANCHORS DESIGNED TO RESIT 5

KIPS. FOLLOW MANUFACTUERS RECOMENDATION FOR MINIUM EMBED,

TYP

CONCRETE

BEAM

STANDARD AISC SHEAR CONNECTION

DESIGNED FOR 5 KIPS ASD, TYP

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.0

N u c M e d v d c h ri s te n s e n M

N F

X

.r v t

/2

/2

:1

:2

A

M

AE104

PARTIAL FIRST & SECOND FLOOR

/ ROOF PLANSGUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

HEAPY

1400 W. DOROTHY LANE

DAYTON, OH 45409

937.224.0861

RELOCATE NUCLEAR MEDICINE

SERVICES FOR CENTRALIZED

SERVICES

INDIANAPOLIS, IN

583-20-102

01/28/2021 JF EB

BID DOCUMENTS

FULLY SPRINKLERED

Revisions: Date:

SCALE: 1/8" = 1'-0"AE104

4 PARTIAL FIRST FLOOR PLAN

SCALE: 1/8" = 1'-0"AE104

3 PARTIAL SECOND FLOOR ROOF PLAN

N N

SCALE: 3" = 1'-0"AE104

1 DUCT PENETRATION CURB

SCALE: 3/4" = 1'-0"AE104

2 TYPICAL OPENING THRU SLAB DETAIL

NOTE:

INSTALL DUCT ALONG SPANDREL GLAZING

WHERE APPLICABLE.

DUCT ACROSS

ROOF, SEE MECHANICAL

DUCT UP

WALL, SEE

MECHANCIAL

DRAWINGS

DUCT UP

WALL, SEE

MECHANICAL

DUCT UP WALL, SEE MECHANICAL

DRAWINGS

N

KEY PLAN

PROJECT

LOCATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.0

N u c M e d v d c h ri s te n s e n M

N F

X

.r v t

/2

/2

:5

:3

A

M

AE105

PARTIAL THIRD & FOURTH FLOOR

/ ROOF PLANSGUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

HEAPY

1400 W. DOROTHY LANE

DAYTON, OH 45409

937.224.0861

RELOCATE NUCLEAR MEDICINE

SERVICES FOR CENTRALIZED

SERVICES

INDIANAPOLIS, IN

583-20-102

01/28/2021 JF EB

BID DOCUMENTS

FULLY SPRINKLERED

Revisions: Date:

SCALE: 1/8" = 1'-0"AE105

1 PARTIAL THIRD FLOOR ROOF PLAN

SCALE: 1/8" = 1'-0"AE105

2 PARTIAL FOURTH FLOOR PLAN

NN

NOTE:

1. SEE DETAIL 4/AE104 FOR PIPE SUPPORT CURB DETAIL.

2. INSTALL DUCT ALONG SPANDREL GLAZING WHERE APPLICABLE.

KEY PLAN

PROJECT

LOCATION

DUCT UP WALL, SEE

MECHANICAL DRAWINGS

DUCT UP WALL, SEE

MECHANICAL DRAWINGS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.0

N u c M e d v d c h ri s te n s e n M

N F

X

.r v t

/2

/2

:5

:3

A

M

AE106

PARTIAL FIFTH & SIXTH FLOOR /

ROOF PLANSGUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

HEAPY

1400 W. DOROTHY LANE

DAYTON, OH 45409

937.224.0861

RELOCATE NUCLEAR MEDICINE

SERVICES FOR CENTRALIZED

SERVICES

INDIANAPOLIS, IN

583-20-102

01/28/2021 JF EB

BID DOCUMENTS

FULLY SPRINKLERED

Revisions: Date:

SCALE: 1/8" = 1'-0"AE106

1 PARTIAL FIFTH FLOOR ROOF PLAN

SCALE: 1/8" = 1'-0"AE106

2 PARTIAL SIXTH FLOOR PLAN

NN

NOTE:

KEY PLAN

PROJECT

LOCATION

DUCT UP

WALL, SEE

MECHANICAL

DUCT UP WALL, SEE

MECHANICAL DRAWINGS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.0

N u c M e d v d c h ri s te n s e n M

N F

X

.r v t

/2

/2

:5

:4

A

M

AE107

PARTIAL SEVENTH & EIGHTH

FLOOR PLANSGUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

HEAPY

1400 W. DOROTHY LANE

DAYTON, OH 45409

937.224.0861

RELOCATE NUCLEAR MEDICINE

SERVICES FOR CENTRALIZED

SERVICES

INDIANAPOLIS, IN

583-20-102

01/28/2021 JF EB

BID DOCUMENTS

FULLY SPRINKLERED

Revisions: Date:

SCALE: 1/8" = 1'-0"AE107

1 PARTIAL SEVENTH FLOOR PLAN

SCALE: 1/8" = 1'-0"AE107

2 PARTIAL EIGHTH FLOOR PLAN

N N

NOTE:

DUCT UP WALL,

SEE MECHANICAL

DUCT ALONG ROOF

SEE MECHANICAL

EXHAUST FAN AND STACK,

SEE 2/AE108. COORDINATE

WITH MECHANICAL DRAWINGS

NOTE:

INSTALL DUCT ALONG SPANDREL GLAZING WHERE

APPLICABLE.

N

KEY PLAN

PROJECT

LOCATION

ROOF

EXHAUST

FAN

GUY WIRE (4 REQUIRED)

WELDED STAINLESS

STEEL EXHAUST STACK

SECURE GUY WIRE

TO ROOF (TYP.)

SECURE

STACK

TO

ROOF

(TYP.)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

U s e rs \d c h ri s te n s e n \D o c u m e n ts \1

.1

.0

N u c M e d v d c h ri s te n s e n M

N F

X

.r v t

/2

/2

:5

:4

A

M

AE108

PARTIAL NINTH FLOOR ROOF

PLANGUIDON DESIGN, INC.

1221 N. PENNSYLVANIA STREET

SUITE 200

INDIANAPOLIS, INDIANA 46202

317.800.6388

HEAPY

1400 W. DOROTHY LANE

DAYTON, OH 45409

937.224.0861

RELOCATE NUCLEAR MEDICINE

SERVICES FOR CENTRALIZED

SERVICES

INDIANAPOLIS, IN

583-20-102

01/28/2021 JF EB

BID DOCUMENTS

FULLY SPRINKLERED

Revisions: Date:

SCALE: 1/8" = 1'-0"AE108

1 PARTIAL NINTH FLOOR ROOF PLAN

N

NOTE:

1. SEE DETAIL 4/AE104 FOR PIPE SUPPORT CURB DETAIL, COORDINATE WITH

MECHANICAL DRAWINGS.

SCALE: 1/2" = 1'-0"AE108

2 EXHAUST FAN AND STACK

NOTE: COORDINATE FINAL DESIGN WITH MECHANICAL DRAWINGS.