511-21325CAK_E101_ADDENDUM2.pdf
PDF 139 KB Posted
- Attached to
- 511/21325. CAK; Alma Armory - Renovate Armor
- Solicitation number
- RFQ - 171 - 230000000729
- Issued by
- Gratiot County, Allendale CDP, Michigan
About this file
This document is an addendum to a state and local government contract opportunity for the renovation of the Alma Armory in Alma, Michigan. The project is being managed by the Michigan Department of Technology, Management and Budget Facilities and Business Services Administration on behalf of the Michigan Department of Military and Veterans Affairs. The addendum provides details on the electrical work to be performed, including the installation of a new communications pedestal, electrical service, panelboards, receptacles, exhaust fans, and motor starters. The bid documents must be submitted electronically through the State of Michigan's SIGMA VSS system, with a bid deadline of 2:00 p.m. on the specified date.
The addendum does not provide information on pricing, funding sources, set-asides, or the incumbent contractor. However, it does indicate that the project is located in Gratiot County and the Allendale Census Designated Place (CDP) in Michigan.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FACP
G
FI 42
G
FI
42"
F F
F
F
42"
42"42"
42"
TV
84"
TV
84"
F
F
FF
F
F F
F
EWC
GFI
G
FI 42
WP
GFI
(E) PANEL
PULL BOX
(E) MDP
E
DD1
EX. C/T
METER
CABINET
B
H
C
DRILL HALL
DLC
COMMANDER
134CORRIDOR
1ST SEARGANT
READINESS
TRAINING
CORRIDOR
CLOSET
TOILET
CORRIDOR
RECRUIT
CORRIDOR
VESTIBULE
WOMEN'S ROOM
MEN'S ROOM
LACATION
WOMEN'S SHOWER
MEN'S SHOWER
PHYSICAL TRAINING
BOILER ROOM
MECH OFFICE
PLATOON
COUNCIL
CLASSROOM
MECHANICAL
STATE MAINTENANCE
STATE MAINTENANCE
STORAGE
VEHICLE STORAGE
MAINTENANCE
OFFICE
STORAGE
CORRIDOR
STORAGE
OFFICE
TOILET
JANITOR
SCULLERY
STORAGE
CLASSROOM
129KITCHEN
(E)
(E)
(E)
(E) (E)
(E)
(E)
(E)
(E)
(E)(E) (E)
(E)(E)
(E)
(E) (E)
(E) (E)(E)
(E) (E) (E)
E- 32
E- 34
E- 28
E- 30
3 3
3 3
P-2
G
B-1
P-1
DHW-1
FCU-1
ACCU-1
ERV-1
G- 2,4,6
G- 1,3,5
G- 7,9,11
G- 8
G- 13,15,17
G- 10
G- 12
E- 38
EF-04
VF
C
VF
C
CLASSROOM
TRAINING
TRAINING
LOCKERS
A
ST
AT
E O
F M
IC
HI
GA
N
D E P A R
TM
E N T
O F
TE
C H N O
LO
G Y M A N A G E M E N T
A N D
B U D G E T
FA
C
IL
IT
IE
S
A N D
B U S
IN
E S S
S E R V
IC
E S
A D M
IN
IS
TR
A
TI
O N
A D A M
LA
C H R A D
IR
E C
TO
R
DE
SI
G
N
AN
D
CO
NS
TR
UC
TI
O N
DI
VI
SI
O
N
AL
M A
AR
M
O R
Y R
EN
O
VA
TI
O N
DE
PA
RT
M
EN
T
O F
M
IL
IT
AR
Y
AN
D
VE
TE
RA
NS
AF
FA
IR
S
AL
M A, M
IC
HI
GA
N
D E S
IG
N E D
D R A W N
C H E C K E D
A P P R O V E D
D A
TE
IS
SU
ED
FO
R P R E
LI
M
IN
A R Y
C O N S
TR
U C
TI
O N
F
IN
A L R E C O R D
ID
EN
TI
FI
C
AT
IO
N
N O
P R O
JE
C T
1/
0.
RW
G
IN
D E X
C O D E
DT
M
B7
S H
EE
T
CN CN AR AG
1/
E1
01SCALE : 1/8" = 1'-0"
1 FIRST FLOOR PLAN - POWER
SCALE : 1/8" = 1'-0"
2 BASEMENT FLOOR PLAN - POWER
#KEYNOTES
1 NEW COMMUNICATIONS PEDESTAL MOUNTED NEXT TO BUILDING.
ROUTE WIRING ALONG BUILDING INTO EXISTING COMMUNICATION
CONDUITS. COORDINATE WITH UTILITY AND OWNER.
2 ELECTRICAL INCOMING SERVICE. REFER TO ONE LINE DIAGRAM.
3 NO WORK IN ROOM, UNLESS OTHERWISE NOTED.
4 RELABEL TO PANEL H. UPDATE PANEL SCHEDULE AND UPDATE
LABELS AT DEVICES. REFER TO ONE LINE DIAGRAM.
5 EXTEND EXISTING CONDUIT AND WIRE TO NEW MANUFACTURER
EQUIPPED WP, GFI RECEPTACLE.
6 EXHAUST FAN TO BE CONTROLLED BY ROOM OCCUPANCY
SENSOR.
7 PROVIDE AND INSTALL NEW PANEL IN EXISTING LOCATION.
EXTEND FEEDER AND BRANCH CIRCUITS TO NEW PANEL.
8 VFC/STARTER/DISCONNECT PROVIDED BY MECHANICAL
CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR.
File details come from the government source that posted it. Updated .