511-21325CAK_05 Mech.pdf
PDF 694 KB Posted
- Attached to
- 511/21325. CAK; Alma Armory - Renovate Armor
- Solicitation number
- RFQ - 171 - 230000000729
- Issued by
- Gratiot County, Allendale CDP, Michigan
About this file
This document contains mechanical construction drawings and specifications for the Alma Armory Renovation project for the Michigan Department of Military and Veterans Affairs. The drawings include details for demolishing existing mechanical systems, installing new HVAC equipment, hydronic piping, and roof-mounted equipment. Key features include a new boiler system, fan coil units, energy recovery ventilator, and air-cooled condensing unit. The project is located in Alma, Michigan and is subject to state and local codes and requirements. No bid submission details or contract information is provided in the document.
The document outlines technical specifications for the mechanical systems, including equipment schedules, piping and ductwork details, and control sequences. Contractors are required to coordinate with other trades, protect existing conditions, provide as-built drawings, and comply with all applicable codes and regulations. Pricing, funding sources, and contract terms are not specified in this set of construction documents.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W M
S
M
TH
T
S
NO2
CO
MS
HS
H
CO2
TS
(E)
CAP
PLUG
2"
4"
4" 4"
PLUMBING AND PIPING SYMBOLS
KEYNOTE - NEW
CONTINUATION SYMBOL
NUMBER OF SHEET WHERE
DETAIL APPEARS
NUMBER OF DETAIL ON SHEET
GENERAL MECHANICAL SYMBOLS
ROOM NAME AND NUMBER
POINT WHERE NEW
CONNECTS TO EXISTING
ITEM TO BE DEMOLISHED AREA NOT IN CONTRACT
PIPE RISE
PIPE DROP
PIPE TEE REDUCING 45
DEGREE TEE
45 DEGREE TEE
* NOTE *
ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER
DRAWINGS IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS
SHEET MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS.
16"x8"
16"/8"
(E)
F
S
M
B
D
C
16"Ø
E/A
O/A
T/A
L/A
R/A
S/A
EXHAUST AIR
OUTSIDE AIR
RELIEF AIR
RETURN AIR
SUPPLY AIR
TRANSFER AIR
GRILLES, REGISTERS & DIFFUSERS TAG
CFM
THROW-150FPM/ 100FPM/ 50FPM
NECK SIZE / MODULE SIZE
EXISTING DUCT TAG
OVAL DUCT SIZE TAG (WIDTH / HEIGHT)
SQUARE DUCT SIZE TAG (WIDTH x HEIGHT)
HVAC SYMBOLS
RECTANGULAR SUPPLY/OUTSIDE AIR DUCT RISE
RECTANGULAR RETURN/TRANSFER AIR DUCT RISE
MECHANICAL EQUIPMENT TAGS
ROUND DUCT SIZE TAG (DIAMETER)
LINEAR DIFFUSER TAG
CFM
TYPE (SEE SCHEDULE) NUMBER OF SLOTS /
ACTIVE SLOT LENGTH (PLENUM LENGTH) /
NECK SIZE
DUCT BEING DEMOLISHED
ELEVATION (CENTER OF FACE)
ROUND SUPPLY/OUTSIDE AIR DUCT RISE
ROUND RETURN/TRANSFER AIR DUCT RISE
RECTANGULAR EXHAUST/RELIEF AIR DUCT RISE
ROUND EXHAUST/RELIEF AIR DUCT RISE
DROP
DROP
DROP
DROP
DROP
DROP
GE/A GREASE EXHAUST AIR
SE/A SMOKE EXHAUST AIR
EQUIPMENT BY OTHERS
(REFER TO OTHER DISCIPLINE
FOR ADDITIONAL INFORMATION)
EXISTING EQUIPMENT
TO REMAIN
FLUE EXHAUST GAS FLUE
C/A COMBUSTION AIR
S-O/A CONDITIONED OUTSIDE AIR
(E)VAV-XX
VAV-XX
48"x3"
400SLB6
10" / 24x24
300SD2
12" / ---
SD9
LINEAR BAR GRILLE
LINEAR SLOT DIFFUSER
PERFORATED DIFFUSER
WITH DEFLECTORS
ROUND DIFFUSER WITH
ADJUSTABLE PATTERNS
LOUVERED DOUBLE
DEFLECTION GRILLE
12"x10"
500SG5
TYPE (SEE SCHEDULE)
10" / 24x24 H-5/7/1422
400SD1
3-CONE DIFFUSER
THROW PATTERN
MAX NC RATING
1 / 4' - 0" / 8"
200LSD1
8' - 0" AFF
1 / 4' - 0" / 8"
200LSD1
TYP 3
1 / 4' - 0" / 8"
200LSD1
SECTION TOTAL TRACK LENGTH
12"x10" / 24x12
500RG9
LOUVERED GRILLE
12"x10" / 24x24
500RG2
EGGCRATE RETURN
GRILLE
BOTTOM OF EQUIPMENT
ELEVATION
505 lb
RTU-XX
3.0 ton
RTU-XX
115000 Btu/h
115 CFH
RTU-XX
HEATING COIL FLOW OPERATING WEIGHT
NOT INCLUDING CURB
FUEL INPUT
GAS PIPE FLOW
NOMINAL COOLING
CAPACITY
ROOFTOP UNIT
PIPE ACCESSORY TAGS
DATA DEVICE TAGS
DAMPER TAGS
MANUAL BALANCING DAMPER
BACKDRAFT DAMPER
COMBINATION FIRE/SMOKE
DAMPER
FIRE DAMPER
SMOKE DAMPER
MOTORIZED DAMPER
KEYNOTE - DEMOLITION#
EQUIPMENT ABBREVIATIONS
BY EXECUTING THE CONSTRUCTION AGREEMENT, THE CONTRACTOR REPRESENTS THAT THEY
HAVE VISITED THE SITE, FAMILIARIZED THEMSELVES WITH THE LOCAL CONDITIONS UNDER
WHICH THE WORK IS TO BE PERFORMED, CORRELATED HIS OBSERVATIONS WITH ALL THE
REQUIREMENTS OF THE CONTRACT DOCUMENTS, AND IS AWARE OF THE OWNER'S INTENDED
USE OF THE PROJECT AREA. ANY AREAS WHERE ADDITIONAL INFORMATION IS REQUIRED ARE
TO BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER, IN WRITING.
CONTRACTOR:
INSTALL WORK SUBSTANTIALLY AS INDICATED ON THE DRAWINGS. VERIFY EXACT LOCATION
AND ELEVATIONS AT THE SITE. DO NOT SCALE THE DRAWINGS. MAKE NECESSARY CHANGES IN
ELEVATION, FITTINGS OR OFFSETS TO ACCOMMODATE OBSTACLES OR INTERFERENCES. ALL
DIMENSIONS ARE TO BE FIELD VERIFIED BEFORE START OF WORK.
THE CONTRACTOR IS TO PROTECT FURNISHINGS, EQUIPMENT, ETC., AND PROPERLY STORE
MATERIAL AS REQUIRED UNTIL COMPLETION OF THE PROJECT.
CONTRACTOR TO VERIFY ALL MEASUREMENTS BEFORE ORDERING MATERIALS OR DOING ANY
WORK. NO EXTRA COMPENSATION OR CHANGE ORDERS WILL BE ISSUED DUE TO
DIFFERENCES BETWEEN THE ACTUAL MEASUREMENT AND THE DIMENSIONS ON THE
DRAWINGS. CONTRACTOR SHALL LAY OUT ALL EQUIPMENT PRIOR TO FABRICATION OR
INSTALLATION TO ASSURE PROPER FIT AND AVOIDANCE OF OBSTRUCTIONS, AND SHALL
THOROUGHLY COORDINATE WORK WITH ALL TRADES AND DETERMINE EXACT ROUTE AND
LOCATION OF EACH ELEMENT AND PIECE OF EQUIPMENT BEFORE FABRICATION AND
INSTALLATION.
CONTRACTOR TO BE RESPONSIBLE FOR KEEPING THE GENERAL WORK AREA CLEAN AND FREE
FROM DIRT AND CONSTRUCTION MATERIALS, AND FOR CLEANING THE AREA AT THE END OF
EACH DAY. ANY AND ALL DAMAGE TO THE EXISTING WALLS, CEILINGS, FLOOR, ETC., THAT
OCCURS DURING THE WORK, SHALL BE REPAIRED AND PATCHED. IF THE SPECIFIC METHOD OF
REPAIR IS IN QUESTION, THE CONTRACTOR IS TO CONFER WITH THE OWNER'S
REPRESENTATIVE BEFORE COMMENCING THE REPAIR.
THE CONTRACTOR SHALL MAINTAIN ON THE SITE FOR THE OWNER A COMPLETE SET OF
CONTRACT DOCUMENTS AND ALL COPIES OF APPROVED SHOP DRAWINGS, ALL CHANGE
ORDERS, FIELD ORDERS, AND BULLETINS, PROGRESSIVELY FILED AND UPDATED TO REFLECT
THE LATEST CHANGES.
THE CONTRACTOR IS TO PROVIDE AS-BUILT DRAWINGS AT THE COMPLETION OF THE PROJECT.
CONTRACTOR ACKNOWLEDGES HE HAS VERIFIED WITH THE OWNER'S REPRESENTATIVE ALL
OF THE DETAILS OF THE WORK TO BE PERFORMED INCLUDING THE ACCURACY OF ALL
CONTRACT DRAWINGS AND SPECIFICATIONS. ALL MATERIALS AND EQUIPMENT ARE TO BE
INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND
SPECIFICATIONS, UNLESS NOTED OTHERWISE.
ALL DEFECTS IN EQUIPMENT OR MATERIALS, OR ERRORS IN THE DRAWINGS DISCOVERED
DURING THE PERFORMANCE OF THE WORK SHALL BE REPORTED PROMPTLY TO THE OWNER'S
REPRESENTATIVE. IN NO EVENT SHALL THE WORK PROCEED UNTIL DEFECTS AND/OR ERRORS
HAVE BEEN RESOLVED.
THE PLANS ARE DIAGRAMMATIC AND INDICATE ONLY THE SIZE AND GENERAL ARRANGEMENT
OF PIPING AND EQUIPMENT. EXACT LOCATION OF ALL ELEMENTS SHALL BE DETERMINED AS
WORK PROGRESSES, IN COOPERATION AND COORDINATION WITH THE WORK OF ALL OTHER
TRADES. IT IS NOT INTENDED TO SHOW EVERY ITEM OF WORK OR MINOR PIECE OF
EQUIPMENT, BUT THE CONTRACTOR SHALL FURNISH AND INSTALL WITHOUT ADDITIONAL
REMUNERATION ANY COMPONENT NECESSARY TO COMPLETE THE SYSTEM IN ACCORDANCE
WITH THE BEST PRACTICE OF THE TRADE.
PIPING AND/ OR DUCT PENETRATION FIRE WALLS AND FLOORS SHALL BE FIRESTOPPED OR
HAVE A FIRE DAMPER. REFER TO THE ARCHITECTURAL DRAWINGS FOR FIRE WALL AND FLOOR
LOCATION.
ALL PHYSICAL ATTRIBUTES OF EQUIPMENT AND DEVICES ARE BASED ON THOSE
MANUFACTURERS LISTED IN THE SPECIFICATIONS AND/ OR THE EQUIPMENT SCHEDULES. THE
RESPECTIVE CONTRACTORS ARE RESPONSIBLE FOR ALL CHANGES BROUGHT ABOUT BY USE
OF ITEMS BY OTHER MANUFACTURERS. THE ARCHITECT/ ENGINEER HAS RESERVED THE RIGHT
TO REJECT ITEMS BY OTHER MANUFACTURERS IF THOSE ITEMS DO NOT MATCH THE PHYSICAL
ATTRIBUTES OF THE MANUFACTURERS LISTED.
CODES AND REGULATIONS:
THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, RULES,
REGULATIONS AND ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF
THE WORK, BOTH ON AND OFF SITE. IF ANY OF THE CONTRACT DOCUMENTS ARE AT VARIANCE
THEREWITH IN ANY RESPECT, CONTRACTOR SHALL PROMPTLY NOTIFY THE OWNER'S
REPRESENTATIVE IN WRITING.
CONTRACTOR REPRESENTS AND WARRANTS COMPLIANCE WITH ALL FEDERAL, STATE, AND
LOCAL LAWS, ORDINANCES AND REGULATIONS APPLICABLE TO THIS ORDER, INCLUDING THE
BUILDING CODE, AND THE LOCAL GOVERNING BODY.
FINAL COMPLETION:
PERFORM ALL OF THE WORK REQUIRED TO COMPLETE THE PROJECT, INCLUDING THE
SATISFACTORY OPERATION OF ALL EQUIPMENT, AND THE CORRECTION OF ALL
UNACCEPTABLE OR INCOMPLETE PORTIONS OF THE PROJECT TO THE SATISFACTION OF THE
OWNER'S REPRESENTATIVE, SETTLE ALL CLAIMS AND SECURE THE RELEASE OF ALL
MECHANICS LIEN OR LIENS OF A LIKE NATURE, AND SECURE THE ISSUANCE BY AN
APPROPRIATE GOVERNMENT AUTHORITY OF A CERTIFICATE OF OCCUPANCY. REMOVE ALL
RUBBISH, SURPLUS MATERIALS, SCAFFOLDING, AND EQUIPMENT FROM THE SITE WHETHER OR
NOT LEFT BY OR BELONGING TO THE CONTRACTOR.
WRITING.
BUILDING CODE
ENERGY EFFICIENCY COMPLIANCE PATH
CLIMATE ZONE:
COMMERCIAL
RESIDENTIAL
XNEW CONSTRUCTION
RENOVATIONX
STATE ENERGY CODE:
ASHRAE 90.1: IECC:
PRESCRIPTIVE
SIMPLE
COMPLEX
PERFORMANCE
ENERGY COST BUDGET
APPENDIX G
ENERGY EFFICIENCY STATEMENT
TO THE BEST OF OUR KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT, THE
MECHANICAL PLANS AND SPECIFICATIONS COMPLY WITH THE LATEST EDITION OF THE
LOCAL ENERGY CONSERVATION CONSTRUCTION CODES.
MECH. ENGINEER
4MICHIGAN
2015 2015
JURISDICTION: [FILL OUT]
GENERAL NOTES
DOMESTIC WATER METER
CIRCUT SETTER VALVE
BALL VALVE
CHECK VALVE
THREE WAY VALVE
BUTTERFLY VALVE
MOTORIZED CONTROL VALVE
PRESSURE REDUCING VALVE
SOLENOID VALVE
THREE WAY MOTORIZED
CONTROL VALVE
BACKFLOW PREVENTER
ELBOW WITH
TURNING VANES
R
W RADIUS ELBOW
CENTER LINE RADIUS (R = 1.5 x W)
OPPOSED BLADE DAMPER PARALLEL BLADE DAMPER
FLEX DUCT
GENERAL ABBREVIATIONS
NAME
COMPLIANCE WITH THE FOLLOWING CODES
IS HEREBY A REQUIREMENT OF THESE
DOCUMENTS. USE THE LATEST VERSIONS
UNLESS NOTED OTHERWISE:
1. BUILDING CODE OF
2. FIRE CODE OF
3. PLUMBING CODE OF
4. MECHANICAL CODE OF
5. ENERGY CONSERVATION
CONSTRUCTION CODE OF
6. CODES, POLICIES & PLAN REVIEW
CONDITIONS OF THE LOCAL
MUNICIPALITY
7. REQUIREMENTS OF THE AUTHORITY
HAVING JURISDICTION
MICHIGAN
MICHIGAN
MICHIGAN
MICHIGAN
MICHIGAN
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR
HUMIDISTAT
HUMIDITY SENSOR
NITROGEN DIOXIDE SENSOR
SENSOR
TEMPERATURE & HUMIDITY SENSOR
THERMOSTAT
TEMPERATURE SENSOR
MANUAL SWITCH
HYDRONIC FINNED TUBE
RADIATORFT-XX
EXISTING PIPE
PIPING BEING DEMOLISHED
PIPE SIZE TAG (DIAMETER)
MAKE-UP WATER
MEDIUM PRESSURE STEAM
MEDIUM PRESSURE CONDENSATE
LOW PRESSURE STEAM
LOW PRESSURE CONDENSATE
HEATING WATER SUPPLY
HEATING WATER RETURN
HIGH PRESSURE STEAM
HIGH PRESSURE CONDENSATE
FUEL GAS VENT
COOLING TOWER SUPPLY
COOLING TOWER RETURN
COMBUSTION AIR VENT
CHILLED WATER SUPPLY
CONDENSATE DRAIN
CHILLED WATER RETURN
COMPRESSED AIRCA
CD
CHWR
CHWS
COMB
CTR
CTS
FGV
HPC
HPS
HWR
HWS
LPC
LPS
MPC
MPS
MU
2"
VACUUM
STEAM VENT
REFRIGERANT-SUCTION
REFRIGERANT-LIQUID
REFRIGERANT-HOT GAS
RADIANT HOT WATER SUPPLY
PUMP CONDENSATE
RADIANT HOT WATER RETURN
NATURAL GASNG
PC
RHWR
RHWS
RHG
RL
RS
SV
VAC
BOP: 2' - 9"
FLEX PIPE
PIPE GUIDE
PIPE ANCHOR
A
G
PIPE SLOPE TAG
BOTTOM OF PIPE ELEVATION
ABOVE FINISHED FLOOR
1/8" / 12" SLOPE
DRAWING INDEX
REVISION NUMBER -
SHOWN ON PLANS
POINT OF DISCONNECTION
VAV-XX
9' - 6"
Htg: 3.7 GPM
VAV-XX
BALANCING VALVE
B B DAMPER
S T
A T
E O
F M
IC
H
IG
A
N
D E P A R T M E N T
O F
T E C H N O
LO
G Y M A N A G E M E N T
A N D
B U D G E T
F A C
IL
IT
IE
S
A N D
B U S
IN
E S S
S E R V
IC
E S
A D M
IN
IS
T R A T
IO
N
A D A M
LA
C H R A D
IR
E C T O R
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
A L
M A
A R
M O
R Y
R E
N O
V A
T
IO
N D
E P
A R
T M
E N
T O
F M
IL
IT
A R
Y A
N D
V E
T E
R A
N S
A F
F A
IR
S
S
S
T A
T E
S T
A
L M
A
M
IC
H
IG
A N
D E S
IG
N E D
D R A W N
C H E C K E D
A P P R O V E D
D A T E
IS
S U E D
F O R
P R E L
IM
IN
A R Y
C O N S T R U C T
IO
N
F
IN
A L
R E C O R D
ID
E N T
IF
IC
A T
IO
N
N O
P R O J E C T
/2
.C
A K
IN
D E X
C O D E
S H E E T
T T
T T
R G
R G
1/
M
M000 MECHANICAL LEGEND SHEET
MD101 LEVEL 1 MECHANICAL DEMOLITION PLAN
M101 1ST FLOOR HVAC PLAN
M111 1ST FLOOR HYDRONIC PIPING PLAN
M120 ROOF MECHANICAL PLAN
M500 MECHANICAL DETAILS
M600 HVAC SCHEDULES
HB HOSE BIB
HC HANDICAPPED
HD HEAD
HOA HAND-OFF-AUTO
HORIZ HORIZONTAL
HP HORSE POWER
HTG HEATING
HTR HEATER
HVAC HEATING VENTILATION AND AIR
CONDITIONING
HW HOT WATER
HZ HERTZ
ID INSIDE DIAMETER
IN INCH/INCHES
IN W.G. INCHES OFWATER GAUGE
INL INLET
INSUL INSULATION
INT INTERIOR
INV INVERT
IPS IRON PIPE SIZE
JST JOIST
JT JOINT
KW KILOWATTS
KWH KILOWATTS PER HOUR
L LENGTH
LAT LEAVING AIR TEMPERATURE
LB POUNDS
LF LINEAL FOOT
LOC LOCATION
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH ONE THOUSAND BTU PER HOUR
MCF ONE THOUSAND CUBIC FEET
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MR MOISTURE RESISTANT
MTD MOUNTED
MTG MOUNTING
MTL METAL
MTR MOTOR
N NECK
NA NOT APPLICABLE
NC NORMALLY CLOSED
NC NOISE CRITERIA
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM NOMINAL
NON
COMB
NON COMBUSTIBLE
NTS NOT TO SCALE
OA OUTSIDE AIR
OC ON CENTER
OD OUTSIDE DIAMETER
PD PRESSURE DROP
PH PHASE
PI PRESSURE INDEPENDENT
PLBG PLUMBING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH
GAUGE
PVC POLYVINYL CHLORIDE
PW POTABLE WATER
PWR POWER
R RISER
RA RETURN AIR
RAD RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
RED REDUCER
REFR REFRIGERATION
REG REGISTER
REINF REINFORCED
REL RELOCATE
REM REMOVABLE
REQ REQUIRE/REQUIRED
RH RELATIVE HUMIDITY
RL/A RELIEF AIR
RM ROOM
RO ROUGH OPENING
RPM REVOLUTIONS PER MINUTE
RPZ REDUCED PRESSURE ZONE
RTD RATED
RTG RATING
SA SUPPLY AIR
SCHED SCHEDULE
SD SMOKE DAMPER
SECT SECTION
SF SQUARE FEET/FOOT
SIM SIMILAR
SM SURFACE MOUNTED
SP STATIC PRESSURE
SPEC SPECIFIED OR SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STRUCT STRUCTURE OR STRUCTURAL
SYS SYSTEM
T THERMOSTAT
TCP TEMPERATURE CONTROL PANEL
TD TEMPERATURE DROP
TEMP TEMPERATURE
THRU THROUGH
TMPD TEMPERED
TO TRANSFER OPENING
TOB TOP OF BEAM
TP TOTAL PRESSURE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UR URINAL
VERT VERTICAL
VIF VERIFY IN FIELD
W WITH
W/O WITHOUT
WC WATER CLOSET
WM WIRE MESH
WT WEIGHT
WWM WELDED WIRE MESH
& AND
@ AT
Ø ROUND
ABV ABOVE
ACOUS ACOUSTICAL
ACT ACOUSTIC CEILING TILE
AD ACCESS DOOR
ADD ADDENDUM
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFUE ANNUAL FUEL UTILIZATION
EFFICIENCY
AG ABOVE GROUND
AHJ AUTHORITY HAVING
JURISDICTION
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ATTN ATTENTION
AUTO AUTOMATIC
BFF BELOW FINISHED FLOOR
BLDG BUILDING
BLKG BLOCKING
BLW BELOW
BM BEAM
BO BY OTHER
BOP BOTTOM OF PIPE
BOT BOTTOM
BSMT BASEMENT
BTU BRITISH THERMAL UNITS
BTUH BRITISH THERMAL UNITS PER
HOUR
BTWN BETWEEN
CAP CAPACITY
CAT CATEGORY
CB CATCH BASIN
CC CENTER TO CENTER
CD CONDENSATE DRAIN
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CL CENTERLINE
CLG CEILING
CLG COOLING
CO CLEANOUT
COL COLUMN
COMB COMBINATION
CONC CONCRETE
COND CONDENSATE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CTR CENTER
CUFT CUBIC FEET
D DEEP, DEPTH
DB DRY BULB
DEG DEGREE
DEMO DEMOLISH OR DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIM DIMENSION/DIMENSIONS
DIV DIVISION
DN DOWN
DRN DRAIN
DTL DETAIL
DV DISPLACEMENT VENTILATION
DWG DRAWING
EA EACH
EAT ENTERING AIR TEMPERATURE
EDB ENTERING DRY BULB
TEMPERTURE
EL ELBOW
ELEC ELECTRICAL
ELEV ELEVATION
EMER EMERGENCY
ENCL ENCLOSURE
ENG ENGINEER
EPDM ETHYLENE PROPYLENE DIENE
M-CLASS
EQ EQUAL
EQUIP EQUIPMENT
EWB ENTERING WET BULB
TEMPERTURE
EWT ENTERING WATER TEMPERATURE
EX EXISTING
EXH EXHAUST
EXH-1 EXHAUST AIR - TYPE 1
EXH-2 EXHAUST AIR - TYPE 2
EXP EXPANSION
EXPJT EXPANSION JOINT
EXT EXTERIOR
F DEGREES FAHRENHEIT
FC FAIL CLOSED
FD FLOOR DRAIN
FLEX FLEXIBLE
FLG FLANGE
FLR FLOOR
FND FOUNDATION
FO FAIL OPEN
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
FPI FINS PER INCH
FPM FEET PER MINUTE
FPS FEET PER SECOND
FS FLOOR SINK
FT FEET/FOOT
FTG FOOTING
FUT FUTURE
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACT
GEN GENERATOR
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
H HIGH/HEIGHT
HVAC GENERAL NOTES
SUPPLY AND RETURN PIPING TO COILS ARE THE SAME SIZE.
CONTRACTOR SHALL LOCATE THERMOSTATS AND TEMPERATURE SENSORS AT 5'-0"
AFF, A MINIMUM OF 8" FROM LIGHT SWITCH.
REFER TO PIPING DRAWINGS FOR THERMOSTAT AND TEMPERATURE SENSOR
LOCATIONS.
CONDENSATE DRAINS SHALL BE SUPPLIED FOR ALL COOLING EQUIPMENT.
CONTRACTOR SHALL ENSURE PROPER INSTALLATION AND DRAINAGE AS REQUIRED BY
FEDERAL, STATE, AND LOCAL CODES. CONDENSATE PIPING SHALL BE TYPE "L" COPPER.
PROVIDE A 4" HOUSEKEEPING PAD FOR EACH PIECE OF MECHANICAL EQUIPMENT.
COORDINATE SIZES WITH MECHANICAL EQUIPMENT SELECTED.
ALL SUPPLY, RETURN, AND EXHAUST DUCTWORK SHALL BE RATED FOR PRESSURE
CLASS OF 2" W.G. UNLESS NOTED OTHERWISE.
THIS CONTRACTOR SHALL BE REQUIRED TO REPLACE FILTERS ON HVAC EQUIPMENT
AFTER ALL DUST PRODUCING CONSTRUCTION HAS BEEN COMPLETED AND PRIOR TO
THE FINAL PUNCH.
FTP FUEL OIL TRANSFER PUMP
G GRILLE
GPR GAS PRESSURE REGULATOR
HC HEATING COIL
HP HEAT PUMP
HTR HEATER
HU HUMIDIFER
HWP HOT WATER PUMP
HX HEAT EXCHANGER
KEX KITCHEN EXHAUST
L LOUVER
LQ LIQUID COOLER
LSD LINEAR SLOT DIFFUSER
M METER
MAU MAKE UP AIR UNIT
MD MOTORIZED DAMPER
OBD OPPOSED BLADE DAMPER
P PUMP
PF PRE-FILTER
PHC PREHEAT COIL
PPU PUMPING PACKAGED UNIT
PRV PRESSURE REDUCING VALVE
R REGISTER
RC REHEAT COIL
RF RETURN FAN
RG RETURN GRILLE
RP RADIANT PANEL
RTU ROOF TOP UNIT
SA SHOCK ABSORBER
SCB SCRUBBER
SD SUPPLY DIFFUSER
SEP SEPARATOR
SF SUPPLY FAN
SG SUPPLY GRILLE
SLB SUPPLY LINEAR BAR GRILLE
SRV SAFETY RELIEF VALVE
TK WATER TANK
TR STEAM TRAP
UH UNIT HEATER
UV UNIT VENTILATOR
VAV VARIABLE AIR VOLUME BOX
VD VOLUME DAMPER
VFD VARIABLE SPEED DRIVE
WS WATER SOFTENER
AC AIR CURTAIN
ACL AIR CLEANER
ACU AIR CONDITIONING UNIT
AD ACCESS DOOR
AHU AIR HANDLING UNIT
AS AIR SEPARATOR
B BOILER
BDD BACK DRAFT DAMPER
BP BOOSTER PUMP
C CONVECTOR
CA AIR COMPRESSOR
CAC COMPRESSED AIR
AFTERCOOLER
CAD COMPRESSED AIR DRYER
CAV CONSTANT AIR VOLUME BOX
CB CHILLED BEAM
CC COOLING COIL
CFP CHEMICAL FEED PUMP
CH CHILLER
CHWP CHILLED WATER PUMP
CP CONDENSATE PUMP
CRAC COMPUTER ROOM UNIT
CRU CONDENSATE RETURN UNIT
CT COOLING TOWER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONTROL VALVE
CWP CONDENSER WATER PUMP
D DAMPER
DEA DEAERATOR
DEX DISHWASHER EXHAUST
DHW DOMESTIC WATER HEATER
DU DEHUMIDIFIER UNIT
ECU EVAPORATIVE CONDENSER UNIT
EF EXHAUST FAN
EJ EXPANSION JOINT
ERV ENERGY RECOVERY VENTILATOR
ERW ENERGY RECOVERY WHEEL
ET EXPANSION TANK
FCU FAN COIL UNIT
FE FILTER, EXHAUST AIR
FF FINAL FILTER
FI FILTER
FR FURNACE
FT FINNED TUBE
12"x10" S/A
18"x12"
18"x12" R/A
EXISTING EXHAUST TO REMAIN
EXISTING
TRANSFER DUCT
TO REMAIN
"x
"x
S /A
"x
S /A
8"Ø
10"x8" E/A
10"x8" E/A
10"x8" E/A
"x
E /A
14"x12" E/A
EXISTING CONVECTOR TO BE
REMOVED AND REINSTALLED IN RM
142. SEE DWG M101 FOR NEW
LOCATION. PIPING SHALL BE REMOVED
BACK TO MAINS AND CAPPED.
EXISTING RA
GRILLE TO
REMAIN
WATER
HEATER TO BE
REMOVED BY
PLUMBING
CONTRACTOR
REMOVE EXISITNG
BUILDING HEATING
PUMPS
REMOVE EXISITNG
BOILER AND PIPING TO
POINTS INDICATED.
EXISTING DIFFUSER TO REMAIN AND
BE RECONNECTED
MEN'S
ROOM
MEN'S
SHOWER
MECH
OFFICE
VESTIBULE
100CORRIDOR
"x
8" E
/A
WOMEN'S
ROOM
BOILER
ROOM
PLATOON
COUNCIL
PHYSICAL
TRAINING
S T
A T
E O
F M
IC
H
IG
A
N
D E P A R T M E N T
O F
T E C H N O
LO
G Y M A N A G E M E N T
A N D
B U D G E T
F A C
IL
IT
IE
S
A N D
B U S
IN
E S S
S E R V
IC
E S
A D M
IN
IS
T R A T
IO
N
A D A M
LA
C H R A D
IR
E C T O R
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
A L
M A
A R
M O
R Y
R E
N O
V A
T
IO
N D
E P
A R
T M
E N
T O
F M
IL
IT
A R
Y A
N D
V E
T E
R A
N S
A F
F A
IR
S
S
S
T A
T E
S T
A
L M
A
M
IC
H
IG
A N
D E S
IG
N E D
D R A W N
C H E C K E D
A P P R O V E D
D A T E
IS
S U E D
F O R
P R E L
IM
IN
A R Y
C O N S T R U C T
IO
N
F
IN
A L
R E C O R D
ID
E N T
IF
IC
A T
IO
N
N O
P R O J E C T
/2
.C
A K
IN
D E X
C O D E
S H E E T
T T
T T
R G
R G
1/
M D
SCALE : 1/4" = 1’−0"
FIRST FLOOR HVAC DEMO
S
8"Ø
8" / 24x24 200S-1
6"Ø
6" / 24x24 50S-1
8" / 24x24 200S-1
(E) 8" / 24x24
200S-1
(E)
8" / 24x24 200S-1
(E)
10"x10" / 24x24 150G1
10"x10" / 24x24 150G1
PHYSICAL
TRAINING
MEN'S
SHOWER
WOMEN'S
SHOWER
MEN'S
ROOM
WOMEN'S
ROOM
LACATION
MECH
OFFICE
BOILER
ROOM
DRILL
HALL
CORRIDOR
VESTIBULE
24"x12"
6" FLUE VENT
THROUGH WHERE
EXISTING 4" VENT WAS
LOCATED, TERMINATE
WITH 180DEG
GOOSENECK PER
MANUFACTURES
REQUIREMENTS.
6" COMBUSTION AIR
INTAKE THROUGH
ROOF, TERMINATE
WITH 180DEG
GOOSENECK PER
MANUFACTURES
REQUIREMENTS.
6"Ø 6"Ø
"x
8"Ø
8"Ø
8"Ø
8" / 24x24 175S-1
8" / 24x24 175S-1
"x
"x
OPEN END DUCT
WITH BIRD SCREEN
DOMESTIC WATER
HEATER BY PLUMBING
CONTRACTOR.
COORDINATE FLUE
INSTALLATION
REQUIREMENTS.
"x
"x
8"
"x
8"
"x
"x
EXISTING
TRANSFER DUCT
TO REMAIN
EXISTING RA
GRILLE TO
REMAIN
8" Ø 6"
Ø
10"x10" / --- 300G1
(E)
U/C DOOR FOR
TRANSFER AIR
10"x10" / 24x24
200RG3
(E)
10"x10" / 24x24
200RG3
(E)
"x
8"
1 1
6"x12"
S-2
ERV-1
6"x12"
S-2
FCU-1
B-1
S T
A T
E O
F M
IC
H
IG
A
N
D E P A R T M E N T
O F
T E C H N O
LO
G Y M A N A G E M E N T
A N D
B U D G E T
F A C
IL
IT
IE
S
A N D
B U S
IN
E S S
S E R V
IC
E S
A D M
IN
IS
T R A T
IO
N
A D A M
LA
C H R A D
IR
E C T O R
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
A L
M A
A R
M O
R Y
R E
N O
V A
T
IO
N D
E P
A R
T M
E N
T O
F M
IL
IT
A R
Y A
N D
V E
T E
R A
N S
A F
F A
IR
S
S
S
T A
T E
S T
A
L M
A
M
IC
H
IG
A N
D E S
IG
N E D
D R A W N
C H E C K E D
A P P R O V E D
D A T E
IS
S U E D
F O R
P R E L
IM
IN
A R Y
C O N S T R U C T
IO
N
F
IN
A L
R E C O R D
ID
E N T
IF
IC
A T
IO
N
N O
P R O J E C T
/2
.C
A K
IN
D E X
C O D E
S H E E T
T T
T T
R G
R G
1/
M
1SCALE : 1/4" = 1’−0"
FIRST FLOOR HVAC PLAN
A. REBALANCE EXISTING DIFFUSERS FOR NEW LAYOUT, (E)
DEIGNATES EXISTING DIFUSSER/GRILLE
B. TEMPERATURE SENSOR TO REMAIN AND BE RECONNECTED TO
NEW RTU-05/HC-1.
KEYED NOTES
1/2" HWR
3/4" HWR
3/4" HWS
1/2" HWS
2 1/2" HWR
2 1/2" HWS
P-2
P-1
B-1
FCU-1
C-1
C-1
C-(E)
C-(E)
C-(E)
C-1
RELOCATED
CONVECTOR
1"
DIFFERENTAIL
PRESSURE
VALVE
1" HWR
1" HWS
DHW-1
ERV-1
ET-1
AS-1
SEE ISO DWG M500
INSTALL NEW PUMPS
AND MODIFY PIPING
TO ACCOMMODATE
PUMP INSTALL
S T
A T
E O
F M
IC
H
IG
A
N
D E P A R T M E N T
O F
T E C H N O
LO
G Y M A N A G E M E N T
A N D
B U D G E T
F A C
IL
IT
IE
S
A N D
B U S
IN
E S S
S E R V
IC
E S
A D M
IN
IS
T R A T
IO
N
A D A M
LA
C H R A D
IR
E C T O R
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
A L
M A
A R
M O
R Y
R E
N O
V A
T
IO
N D
E P
A R
T M
E N
T O
F M
IL
IT
A R
Y A
N D
V E
T E
R A
N S
A F
F A
IR
S
S
S
T A
T E
S T
A
L M
A
M
IC
H
IG
A N
D E S
IG
N E D
D R A W N
C H E C K E D
A P P R O V E D
D A T E
IS
S U E D
F O R
P R E L
IM
IN
A R Y
C O N S T R U C T
IO
N
F
IN
A L
R E C O R D
ID
E N T
IF
IC
A T
IO
N
N O
P R O J E C T
/2
.C
A K
IN
D E X
C O D E
S H E E T
T T
T T
R G
R G
1/
M
1SCALE : 1/4" = 1’−0"
FIRST FLOOR NEW HYDRONIC PIPING PLAN
A. RELOCATE EXISTING HEATER FROM WOMANS RESTROOM TO
LACTATION ROOM
B. NEW RADIANT HEAT IN WOMENS SHOWER ROOM TO MATCH EXISTING
IN WOMENS RESTROOM.
C. NEW DDC VALVE TO CONTROL WOMENS RESTROOM HEAT.
GENERAL NOTES
(E)EF-3
REMOVE EXISTING RTU-05
AND DISCONNECT
EXISITNG NG PIPING AND
CAP
BOILER EXHAUST
ACCU-1
S T
A T
E O
F M
IC
H
IG
A
N
D E P A R T M E N T
O F
T E C H N O
LO
G Y M A N A G E M E N T
A N D
B U D G E T
F A C
IL
IT
IE
S
A N D
B U S
IN
E S S
S E R V
IC
E S
A D M
IN
IS
T R A T
IO
N
A D A M
LA
C H R A D
IR
E C T O R
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
A L
M A
A R
M O
R Y
R E
N O
V A
T
IO
N D
E P
A R
T M
E N
T O
F M
IL
IT
A R
Y A
N D
V E
T E
R A
N S
A F
F A
IR
S
S
S
T A
T E
S T
A
L M
A
M
IC
H
IG
A N
D E S
IG
N E D
D R A W N
C H E C K E D
A P P R O V E D
D A T E
IS
S U E D
F O R
P R E L
IM
IN
A R Y
C O N S T R U C T
IO
N
F
IN
A L
R E C O R D
ID
E N T
IF
IC
A T
IO
N
N O
P R O J E C T
/2
.C
A K
IN
D E X
C O D E
S H E E T
T T
T T
R G
R G
1/
M
SCALE : 1/4" = 1’−0"
ROOF MECHANICAL PLAN
#4 @ 12" E.W. REINFORCING
SLAB ON GRADE OR
SLAB ON STEEL DECK
INSERT #4 BARS @ 12" O.C.
OR DRILL AND GROUT
M
IN
. 1
/2
C L R
3/4" CHAMFER, TYP.
ROUGHEN SURFACE
NOTES:
1. COORDINATE PAD SIZE WITH EQUIPMENT SIZE PRIOR TO INSTALLATION.
2. UNLESS OTHERWISE INDICATED PROVIDE ONE PAD FOR EACH PIECE OF
EQUIPMENT. DO NOT COMBINE PADS.
3. PAD SHALL BE 4" LARGER THAN THE OVERALL EQUIPMENT SIZE.
4" CONCRETE PAD
3"
1"
ANGLE OR PIPE SUPPORT
STEEL BASE PLATE
COUNTER FLASHING
WOOD NAILER
BUILDING INSULATION
BASE SECTION
BUILT-IN CANT
EXISTING ROOF DECK
CURB SECTION
12"
NOTE:
PROVIDE EXISTING ROOF
MANUFACTURER'S STANDARD SELF ROOF
FLASHING CURB. CURB SHALL BE
INSTALLED BY ROOF MANUFACTURER'S
APPROVED INSTALLER TO HONOR ROOF
WARRANTY.
RECTANGULAR MAIN
1" FLANGE
PREFABRICATED
STRAIGHT - SIDED
HIGH EFFICIENCY TAKEOFF
1" FLANGE
RECTANGULAR
BRANCH
R E
T U
R N
/E X
H A
U S
T A
IR
F
L O
W
S U
P P
L Y
A
IR
F L O
W
R E
T U
R N
/E X
H A
U S
T A
IR
F
L O
W
S U
P P
L Y
A
IR
F L O
W
ROUND MAIN
45°
ROUND
BRANCH
W/4, 4" MIN
W/4, 4" MIN
45°
W
W
45°
ROUND
BRANCH
2"
1" FLANGE
2 1/2" FLANGE
PREFABRICATED
45° SADDLE TAP
NOTES:
1. SEAL ALL JOINTS AND SEAMS PER SPECIFICATIONS.
VOLUME DAMPER (TYP)
RECTANGULAR
BRANCH
DUCT CLEANOUT
(TYP.)
(WHEN/WHERE SPECIFIED)
DUCT CLEANOUT
(TYP.)
(WHEN/WHERE SPECIFIED)
GASKET
LOCKNUT
GASKET
INDICATING HANDLE
1/4" SET SCREW
1" X 1/8" GALV. STRAPS
16 GA. GALV. BLADE
3/8" SQ. ROD
1/4" LESS THAN DUCT
3/8" SQ. ROD
SPOT WELD
BLADE DETAIL
SA
SIDE CONNECTION
MAXIMUM 3'-0" LENGTH
FLEXIBLE DUCT FULLY
EXTENDED
ROUND DUCT CONNECTOR
ACOUSTIC
LINING
CEILING
DIFFUSER
NYLON TIE-STRAP
3 ZIP SCREWS MIN.
HOLDING A PIECE OF THE
HELICAL WIRE
INSULATED FLEX
DUCT, 5'-0" MAX
DIFFUSER, TYPICAL LAY-IN MODEL
LAY-IN T-BAR CEILING
NYLON TIE-STRAP
R=D
THERMAL
INSULATION
DIFFUSER TOP CONNECTION
CEILING
MAXIMUM 5'-0"
LENGTH FLEXIBLE
DUCT FULLY
EXTENDED
ROUND DUCT ADAPTOR FOR
RECTANGULAR DIFFUSER
D
DIFFUSER NECK SIZE
3/
4" M
IN
IM
U M
D M
IN
IM
U M
VOLUME DAMPER
FLEXIBLE DUCT SUPPORT STRAP
FLEXIBLE DUCT SUPPORT
STRAP
RA
NYLON TIE-STRAP
3 ZIP SCREWS MIN.
HOLDING A PIECE OF THE
HELICAL WIRE
INSULATED FLEX
DUCT, 5'-0" MAX
FLEXIBLE DUCT
SUPPORT STRAP
M
IN
" 22" x 22" FACE.
6" MINIMUM
6"Ø C/A
6" FLUE
2" NG
BUTTERFLY VALVE
BUTTERFLY VALVE
GAS REGULATOR
3" HWR
3" HWS
EXISTING HWR
EXISTING HWR
B-1
COMBUSTION AIR
TERMINATE AT OUTSIDE
WALL WITH BIRD SCREEN
CAP
6" FLUE, VENT THROUGH
ROOF PER MANUFACTURES
GUIDELINES.
ET-1
3/4" HWS
AS-1
PRV, SET @12PSI
CHECK VALVE
MAKE-UP WATER,
CONNECT TO
EXISTING
GAS COCK
TACO MODEL
CBX84-125
AIR SEPARATOR TACO
MODEL 4903AT-125
S T
A T
E O
F M
IC
H
IG
A
N
D E P A R T M E N T
O F
T E C H N O
LO
G Y M A N A G E M E N T
A N D
B U D G E T
F A C
IL
IT
IE
S
A N D
B U S
IN
E S S
S E R V
IC
E S
A D M
IN
IS
T R A T
IO
N
A D A M
LA
C H R A D
IR
E C T O R
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
A L
M A
A R
M O
R Y
R E
N O
V A
T
IO
N D
E P
A R
T M
E N
T O
F M
IL
IT
A R
Y A
N D
V E
T E
R A
N S
A F
F A
IR
S
S
S
T A
T E
S T
A
L M
A
M
IC
H
IG
A N
D E S
IG
N E D
D R A W N
C H E C K E D
A P P R O V E D
D A T E
IS
S U E D
F O R
P R E L
IM
IN
A R Y
C O N S T R U C T
IO
N
F
IN
A L
R E C O R D
ID
E N T
IF
IC
A T
IO
N
N O
P R O J E C T
/2
.C
A K
IN
D E X
C O D E
S H E E T
T T
T T
R G
R G
1/
M
SCALE : N.T.S.
HOUSEKEEPING PAD
SCALE : N.T.S.
ROOF CURB
SCALE : 12" = 1’−0"
DUCT TAKEOFFS
SCALE : N.T.S.
ROUND VOLUME DAMPER
SCALE : N.T.S.
AIR TERMINAL CONNECTION
BOILER CONTROL SEQUENCE
1. BOILER SYSTEM - RUN CONDITIONS:
A. THE BOILER SYSTEM SHALL BE ENABLED TO RUN WHENEVER OUTSIDE AIR
TEMPERATURE IS LESS THAN 65°F (ADJ.).
B. TO PREVENT SHORT CYCLING, EACH BOILER SHALL RUN FOR AND BE OFF
FOR MINIMUM ADJUSTABLE TIMES (BOTH USER DEFINABLE), UNLESS
SHUTDOWN ON SAFETIES OR OUTSIDE AIR CONDITIONS.
C. EACH BOILER SHALL RUN SUBJECT TO ITS OWN INTERNAL SAFETIES AND
CONTROLS.
D. THE BOILER SYSTEM SHALL ALSO RUN FOR FREEZE PROTECTION
WHENEVER THE OUTSIDE AIR TEMPERATURE IS LESS THAN 38°F (ADJ.).
2. BOILER (B-1) SAFETIES:
A. THE FOLLOWING SAFETIES SHALL BE MONITORED:
B. BOILER ALARM.
C. LOW WATER LEVEL.
D. ALARMS SHALL BE PROVIDED AS FOLLOWS:
E. BOILER ALARM.
F. LOW WATER LEVEL ALARM.
3. HOT WATER PUMP (P-1,P-2) LEAD/LAG OPERATION:
A. THE TWO HOT WATER PUMPS SHALL OPERATE IN A LEAD/LAG FASHION.
B. THE LEAD PUMP SHALL RUN FIRST.
C. ON FAILURE OF THE LEAD PUMP, THE LAG PUMP SHALL RUN AND THE LEAD
PUMP SHALL TURN OFF.
D. ON DECREASING HOT WATER DIFFERENTIAL PRESSURE, THE LAG PUMP
SHALL STAGE ON AND RUN IN UNISON WITH THE LEAD PUMP TO MAINTAIN
HOT WATER DIFFERENTIAL PRESSURE SETPOINT.
E. THE DESIGNATED LEAD PUMP SHALL ROTATE UPON ONE OF THE FOLLOWING
CONDITIONS (USER SELECTABLE):
F. MANUALLY THROUGH A SOFTWARE SWITCH
G. IF PUMP RUNTIME (ADJ.) IS EXCEEDED
H. DAILY
I. WEEKLY
J. MONTHLY
4. ALARMS SHALL BE PROVIDED AS FOLLOWS:
A. HOT WATER PUMP 1
B. FAILURE: COMMANDED ON, BUT THE STATUS IS OFF.
C. RUNNING IN HAND: COMMANDED OFF, BUT THE STATUS IS ON.
D. RUNTIME EXCEEDED: STATUS RUNTIME EXCEEDS A USER DEFINABLE LIMIT.
E. VFD FAULT.
F. HOT WATER PUMP 2
G. FAILURE: COMMANDED ON, BUT THE STATUS IS OFF.
H. RUNNING IN HAND: COMMANDED OFF, BUT THE STATUS IS ON.
I. RUNTIME EXCEEDED: STATUS RUNTIME EXCEEDS A USER DEFINABLE LIMIT.
J. VFD FAULT.
5. HOT WATER DIFFERENTIAL PRESSURE CONTROL:
A. THE CONTROLLER SHALL MEASURE HOT WATER DIFFERENTIAL PRESSURE
AND MODULATE THE HOT WATER PUMP VFDS IN SEQUENCE TO MAINTAIN ITS
HOT WATER DIFFERENTIAL PRESSURE SETPOINT.
B. THE FOLLOWING SETPOINTS ARE RECOMMENDED VALUES. ALL SETPOINTS
SHALL BE FIELD ADJUSTED DURING THE COMMISSIONING PERIOD TO MEET
THE REQUIREMENTS OF ACTUAL FIELD CONDITIONS.
C. THE CONTROLLER SHALL MODULATE HOT WATER PUMP SPEEDS TO
MAINTAIN A HOT WATER DIFFERENTIAL PRESSURE OF 12LBF/IN2 (ADJ.). THE
VFDS MINIMUM SPEED SHALL NOT DROP BELOW 20% (ADJ.).
D. ON DROPPING HOT WATER DIFFERENTIAL PRESSURE, THE VFDS SHALL
STAGE ON AND RUN TO MAINTAIN SETPOINT AS FOLLOWS:
E. THE CONTROLLER SHALL MODULATE THE LEAD VFD TO MAINTAIN SETPOINT.
F. IF THE LEAD VFD SPEED IS GREATER THAN A SETPOINT OF 90% (ADJ.), THE
LAG VFD SHALL STAGE ON.
G. THE LAG VFD SHALL RAMP UP TO MATCH THE LEAD VFD SPEED AND THEN
RUN IN UNISON WITH THE LEAD VFD TO MAINTAIN SETPOINT.
H. ON RISING HOT WATER DIFFERENTIAL PRESSURE, THE VFDS SHALL STAGE
OFF AS FOLLOWS:
I. IF THE VFDS SPEEDS DROPS BACK TO 60% (ADJ.) BELOW SETPOINT, THE LAG
VFD SHALL STAGE OFF.
J. THE LEAD VFD SHALL CONTINUE TO RUN TO MAINTAIN SETPOINT.
6. ALARMS SHALL BE PROVIDED AS FOLLOWS:
A. HIGH HOT WATER DIFFERENTIAL PRESSURE: IF 25% (ADJ.) GREATER THAN
SETPOINT.
B. LOW HOT WATER DIFFERENTIAL PRESSURE: IF 25% (ADJ.) LESS THAN
SETPOINT.
7. REMOTE BOILER SHUTDOWN
A. PROVIDE NORMAL ELECTRICAL POWER TO REMOTE BOILER SHUTDOWN
SYSTEM.
CONVECTOR CONTROL SEQUENCE
1. RUN CONDITIONS - SCHEDULED: THE UNIT SHALL RUN ACCORDING TO A USER
DEFINABLE TIME SCHEDULE IN THE FOLLOWING MODES:
A. OCCUPIED MODE: THE UNIT SHALL MAINTAIN A HEATING SETPOINT OF 70°F
(ADJUSTABLE).
B. UNOCCUPIED MODE (NIGHT SETBACK): THE UNIT SHALL MAINTAIN A HEATING
SETPOINT OF 65°F (ADJUSTABLE.).
2. ALARMS SHALL BE PROVIDED AS FOLLOWS:
A. LOW ZONE TEMP: IF THE ZONE TEMPERATURE IS LESS THAN THE HEATING
SETPOINT BY A USER DEFINABLE AMOUNT (ADJUSTABLE.).
3. HEATING COIL VALVE:
A. THE CONTROLLER SHALL MEASURE THE ZONE TEMPERATURE AND (MODULATE)
(OPEN) THE HEATING COIL VALVE TO MAINTAIN ITS HEATING SETPOINT.THE
HEATING SHALL BE ENABLED WHENEVER:
B. OUTSIDE AIR TEMPERATURE IS LESS THAN 65°F (ADJUSTABLE.) AND THE ZONE
TEMPERATURE IS BELOW HEATING SETPOINT.
FAN COIL UNIT CONTROL SEQUENCE
1. RUN CONDITIONS - SCHEDULED:
A. THE UNIT SHALL RUN ACCORDING TO A USER DEFINABLE TIME SCHEDULE IN THE
FOLLOWING MODES:
a. OCCUPIED MODE: THE UNIT SHALL MAINTAIN
b. A 74°F (ADJ.) COOLING SETPOINT
c. A 70°F (ADJ.) HEATING SETPOINT.
d. UNOCCUPIED MODE (NIGHT SETBACK): THE UNIT SHALL MAINTAIN
e. A 85°F (ADJ.) COOLING SETPOINT.
f. A 55°F (ADJ.) HEATING SETPOINT.
2. ALARMS SHALL BE PROVIDED AS FOLLOWS:
A. HIGH ZONE TEMP: IF THE ZONE TEMPERATURE IS GREATER THAN THE COOLING
SETPOINT BY A USER DEFINABLE AMOUNT (ADJ.).
B. LOW ZONE TEMP: IF THE ZONE TEMPERATURE IS LESS THAN THE HEATING
SETPOINT BY A USER DEFINABLE AMOUNT (ADJ.).
3. ZONE SETPOINT ADJUST
A. THE OCCUPANT SHALL BE ABLE TO ADJUST THE ZONE TEMPERATURE HEATING
AND COOLING SETPOINTS AT THE ZONE SENSOR.
4. FAN:
A. THE FAN SHALL RUN ANYTIME THE UNIT IS COMMANDED TO RUN, UNLESS
SHUTDOWN ON SAFETIES.
5. COOLING STAGE:
A. THE CONTROLLER SHALL MEASURE THE ZONE TEMPERATURE AND STAGE THE
COOLING TO MAINTAIN ITS COOLING SETPOINT. TO PREVENT SHORT CYCLING,
[THE STAGE SHALL HAVE A USER DEFINABLE (ADJ.)] [THERE SHALL BE A USER
DEFINABLE (ADJ.) DELAY BETWEEN STAGES, AND EACH STAGE SHALL HAVE A
USER DEFINABLE (ADJ.)] MINIMUM RUNTIME.
B. THE COOLING SHALL BE ENABLED WHENEVER THE FOLLOWING CONDITIONS ARE
MET:
a. OUTSIDE AIR TEMPERATURE IS GREATER THAN 60°F (ADJ.).
b. THE ZONE TEMPERATURE IS ABOVE COOLING SETPOINT.
c. THE FAN IS ON.
6. HEATING COIL VALVE:
A. THE CONTROLLER SHALL MEASURE THE ZONE TEMPERATURE AND (MODULATE)
(OPEN) THE HEATING COIL VALVE TO MAINTAIN ITS HEATING SETPOINT.
B. THE HEATING SHALL BE ENABLED WHENEVER THE FOLLOWING CONDITIONS ARE
MET:
C. OUTSIDE AIR TEMPERATURE IS LESS THAN 65°F (ADJ.).
D. THE ZONE TEMPERATURE IS BELOW HEATING SETPOINT.
E. THE FAN IS ON.
SCALE :
BOILER ISO
ERV UNIT CONTROL SEQUENCE
1. RUN CONDITIONS - SCHEDULED:
A. THE UNIT SHALL RUN ACCORDING TO A USER DEFINABLE TIME SCHEDULE IN THE
FOLLOWING MODES:
a. OCCUPIED MODE: ON
b. UNOCCUPIED MODE (NIGHT SETBACK):OFF
T
A T
E O
F M
IC
H
IG
A
N
D E P A R T M E N T
O F
T E C H N O
LO
G Y M A N A G E M E N T
A N D
B U D G E T
F A C
IL
IT
IE
S
A N D
B U S
IN
E S S
S E R V
IC
E S
A D M
IN
IS
T R A T
IO
N
A D A M
LA
C H R A D
IR
E C T O R
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
A L
M A
A R
M O
R Y
R E
N O
V A
T
IO
N D
E P
A R
T M
E N
T O
F M
IL
IT
A R
Y A
N D
V E
T E
R A
N S
A F
F A
IR
S
S
S
T A
T E
S T
A
L M
A
M
IC
H
IG
A N
D E S
IG
N E D
D R A W N
C H E C K E D
A P P R O V E D
D A T E
IS
S U E D
F O R
P R E L
IM
IN
A R Y
C O N S T R U C T
IO
N
F
IN
A L
R E C O R D
ID
E N T
IF
IC
A T
IO
N
N O
P R O J E C T
/2
.C
A K
IN
D E X
C O D E
S H E E T
T T
T T
R G
R G
1/
M
6) CONTRACTOR TO PROVIDE 1" DIFFERENTIAL VALVE IN SYSTEM BETWEEN SUPPLY AND RETURN LINE TO MAINTAIN MIN FLOW ON BOILERS. CALEFFI MODEL 519600A OR EQUAL. VALVE SHALL BE INSTALLED IN SYSTEM AT POINT INDICATED ON DRAWINGS
5) BOILER MANUFACTURE SHALL PROVIDER UNIT WITH CONTROLS READY OPTION OR GATEWAY TO CONNECT TO EXISTING LON WORKS NETWORK.
4) PROVIDE CONDENSATE PUMP TO EXISTING HUB DRAIN AT BOILER
3) PROVIDE BOILER SEQUENCING WITH HW RESET
2) BOILER SHALL BE EQUIPPED WITH COMBUSTION AIR TEMPERATURE COMPENSATION TO AUTOMATICALLY COMPENSATE FOR AIR DENSITY CHANGES BY ADJUSTING OXYGEN AND OPTIMIZE THE COMBUSTION EFFICIENCY UNDER ALL SEASONAL TEMPERATURE CHANGES.
1) PROVIDE CONDENSATE NEUTRALIZER FOR EACH BOILER AND COMMON FLUE DRAINS
B-1 96.8 15 14.25 AERCO BMK-1000 25 175 50 160 6 3 120 140 4-14 120/1/60 1,2,3,4,5,6
MIN (GPM) MAX-(GPM) ENTERING LEAVING
TAG
AHRI EFFICIENCY
(BTS-2000)
OPERATING
PRESSURE (PSIG)
BOILER
CAPACITY (GAL)
BASIS OF DESIGN
MANUFACTURER
MODEL
FLOW
RELIEF
VALVE
PRESSURE
(PSIG)
BOILER
PRESSURE
RATING
(PSIG)
VENT SIZE
(IN)
PRESSUR
E
DROP
(PSI)
PRES
(PSI)
WATER TEMP (F)
MIN-MAX
GAS INLET
PRESSURE
(IN W.C.)
POWER
SUPPLY
(V/PH/HZ)
NOTES
GAS-FIRED HOT WATER BOILER SCHEDULE
NOTES 1) UNIT SHALL BE PROVEDED WITH CONTROL READY FOR CONNECTION TO LON WORKS EXISTING CONTROL SYSTEM
FCU-1 ENVIRO-TEC BCU-16 1600 0.75
HIGH
ECM 650 55 80 67 58 56 0.38 56.6 70 102 6 140 120 208/3/60 4.63 3.7 1
DB WB DB WB
AIRFLOW (CFM) ESP (IN-WC)
FAN SPEED
SELECTION
MOTOR TYPE
POWER
(WATTS)
CAPACITY
(BTU/H)
EAT °F LAT °F
PRESS DROP
(FT)
CAPACITY
(BTU/H)
ENTERING AIR
TEMPERATURE (F)
LEAVING AIR
TEMPERATURE (F)
FLOW (GPM)
ENTERING
WATER TEMP (F)
PRESS DROP (FT)
MCA FLATAG
BASIS OF DESIGN
MANUFACTURER
MODEL
FAN SECTION COOLING COIL HEATING COIL
POWER
SUPPLY
(V/PH/HZ)
MOTOR
NOTES
FAN COIL SCHEDULE
ERV-1 PLATE RENEWAIRE EV300 300 0.46 300 85.5 70.1 75.0 62.6 78.3 66.6 -5.9 -6.5 70.0 51.5 47.1 36.5 120/1/60
MODEL DB (F) WB (F) DB (F) WB (F) DB (F) WB (F) DB (F) WB (F) DB (F) WB (F) DB (F) WB (F)
OUTSIDE AIR RETURN AIR SUPPLY AIR OUTSIDE AIR RETURN AIR SUPPLY AIR POWER (V/P/HZ) NOTESTAG TYPE
BASIS OF DESIGN
MANUFACTURER
SUPPLY
(CFM)
ESP (IN WC)
EXHAUST
(CFM)
SUMMER AIR TEMP (F) WINTER SEASON AIR TEMP (F)
ENERGY RECOVERY VENTILATOR SCHEDULE
P-2 CENT B&G E-1510 2AD-es H20 100 27 140 5.75 2.5 2 304SS 304SS CAST COATED 1 0.89 1800 208/3/60 75.9 VFD
P-1 CENT B&G E-1510 2AD-es H2O 100 27 140 5.75 2.5 2 304SS 304SS CAST COATED 1 0.89 1800 208/3/60 75.9 VFD
DIAMETER (IN) INLET OUTLET SHAFT IMPELLER BODY HP BHP RPM POWER SUPPLY (V/PH/HZ) PUMP EFF (%) TYPE
TAG TYPE
BASIS OF DESIGN
MANUFACTURER
SERIES MODEL FLUID TYPE
FLOW RATE
(GPM)
HEAD LOSS
(FT)
MIN FLUID
TEMP (F)
IMPELLER CONNECTION SIZE (IN) MATERIALS OF CONSTRUCTION MOTOR CONTROLS
ACCESSORIES
REQUIRED
NOTES
PUMP SCHEDULE
C-1 STERLING FWG-A 2.2 140 120 0.5 65 0.16 36 32 4/13/2016
TAG DESIGN BASIS MODEL MBH
ENTERING WATER
TEMP (DEG F)
LEAVING WATER
TEMP (DEG F)
FLOW(GPM) ENTERING AIR (DEG F) PRESSURE DROP (IN WC) LENGTH (IN) HEIGHT (IN) DEPTH (IN) NOTES
HYDRONIC CONVECTOR SCHEDULE
ACCU-1 FCU-1 CARRIER 24AHA448A005 4 1.2 18.3 13.7 83.1 208-230/3/60 30 R410 11.7 14.0 DISCONNECT ROOF PAD
FULL LOAD CURRENT
(AMP)
MCA CURRENT (AMP) COMPRESSOR RLA (AMP) COMPRESSOR LRA (AMP) POWER (V/P/HZ) MAX FUSE (AMP)
TAG SERVES
BASIS OF DESIGN
MANUFACTURER
MODEL
CAPACITY
(TONS)
ELECTRICAL
REFRIGERANT EER SEER
ACCESSORIES
REQUIRED
ACCESSORIES
AIR-COOLED CONDENSING UNIT SCHEDULE
| Sheets |
| M000 - MECHANICAL LEGEND SHEET |
| M101 - 1ST FLOOR HVAC PLAN |
| M111 - 1ST FLOOR HYDRONIC PIPING PLAN |
| M120 - ROOF MECHANICAL PLAN |
| M500 - MECHANICAL DETAILS |
| M600 - HVAC SCHEDULES |
| MD101 - LEVEL 1 MECHANICAL DEMOLITION PLAN |
File details come from the government source that posted it. Updated .