Gratiot County, Allendale CDP, Michigan

About this file

This document is a set of architectural and engineering plans for the renovation of the Alma Armory in Alma, Michigan. The project is a joint effort between the Michigan Department of Technology, Management and Budget Facilities and Business Services Administration and the Department of Military and Veterans Affairs. The plans detail the renovation work to be performed, including updates to the building's mechanical, electrical, plumbing, and architectural systems. The project location is 710 S. State St. in Alma, Michigan, and the plans include a demolition plan, site plan, structural plans, architectural plans, and mechanical, electrical, and plumbing plans. The project is subject to the 2015 Michigan Building Code, Michigan Rehabilitation Code, and other applicable state and local codes and regulations.

The contract opportunity related to this project is for the construction work to renovate the Alma Armory. The project bids are due by 2:00 pm on the specified date, and bidders must upload their proposals to the SIGMA VSS system. Questions should be emailed to the designated project contact, and bidders experiencing SIGMA VSS issues should contact the SIGMA help desk. The contract term and any renewal options are not specified in the provided information.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

W. HILLCREST ST

S.

LI

NC

O

LN

AV

E.

W. VAN BUREN RD.

N G

RA

FT

O N

RD

ST

AT

E O

F M

IC

HI

GA

N

D E P A R

TM

E N T

O F

TE

C H N O

LO

G Y M A N A G E M E N T

A N D

B U D G E T

FA

C

IL

IT

IE

S

A N D

B U S

IN

E S S

S E R V

IC

E S

A D M

IN

IS

TR

A

TI

O N

A D A M

LA

C H R A D

IR

E C

TO

R

DE

SI

G

N

AN

D

CO

NS

TR

U

CT

IO

N

DI

VI

SI

O

N

AL

M A

AR

M

O R

Y R

EN

O

VA

TI

O N

DE

PA

RT

M

EN

T

O F

M

IL

IT

AR

Y

AN

D

VE

TE

RA

NS

AF

FA

IR

S

S.

ST

AT

E

ST

.A

LM

A, M

IC

HI

G

AN

D E S

IG

N E D

D R A W N

C H E C K E D

A P P R O V E D

D A

TE

IS

SU

ED

FO

R P R E

LI

M

IN

A R Y

C O N S

TR

U C

TI

O N

F

IN

A L R E C O R D

ID

EN

TI

FI

C

AT

IO

N

N O

P R O

JE

C T

A1

IN

D E X

C O D E

S H

EE

T

DRAWING INDEXPROJECT CONTACT LIST

PROJECT LOCATION MAP

7050 West Saginaw Hwy. // Suite 200 // Lansing, MI 48917

517.272.9835 / 517.272.9836 fax www.bergmannpc.com

FOR

CONSTRUCTION

OWNER:

- DMVA

- 3411 N MLK BLVD

LANSING, MI

- CONTACT: ADAM POHL

-PHONE: 517-481-7585

-DTMB

-4125 W. ST. JOE HWY

LANSING, MI

- CONTACT: CHRIS KULHANEK

- PHONE: 517-284-7969

STRUCTURAL ENGINEER:

- BERGMANN

- 7050 W SAGINAW HWY, SUITE 200

LANSING, MI

- CONTACT: KIERA TENNES

- PHONE: 517-272-9835

ARCHITECT:

- BERGMANN

- 7050 W SAGINAW HWY, SUITE 200

LANSING, MI

- CONTACT: DAVID LENZ

- PHONE: 517-272-9835

CIVIL ENGINEER:

- BERGMANN

- 7050 W SAGINAW HWY, SUITE 200

LANSING, MI

- CONTACT: PAUL FURTAW

- PHONE: 517-272-9835

MECHANICAL ENGINEER:

- BERGMANN

- 7050 W SAGINAW HWY, SUITE 200

LANSING, MI

- CONTACT: PAUL JANSEN

- PHONE: 517-272-9835

ELECTRICAL ENGINEER:

- BERGMANN

- 7050 W SAGINAW HWY, SUITE 200

LANSING, MI

- CONTACT: ANGELA ROBINSON

- PHONE: 517-272-9835

DEPARTMENT OF MILITARY

AND VETERAN AFFAIRS

3411 N MARTIN LUTHER KING JR BLVD.

LANSING MI

DP

L

DP

L

DP

L

XX

X

1/

G0

ALMA ARMORY RENOVATION

08/21/2023

710 S STATE ST

ALMA, MI 48801

00 - GENERAL

G000 COVER SHEET

G001 CODE REVIEW

G002 CODE COMPLIANCE & LIFE SAFETY PLANS

02 - CIVIL

C100 DEMOLITION PLAN

C200 SITE PLAN

C201 OVERALL SITE PLAN

C300 SESC PLAN

C301 SESC DETAILS

C400 UTILITY PLANS

C700 DETAILS

03 - STRUCTURAL

S001 GENERAL NOTES

S002 GENERAL NOTES

S010 DESIGN LOADS

S101 PLANS

S102 PLANS

S201 MASONRY ELEVATIONS

S501 SECTIONS & DETAILS

S901 ISOMETRIC VIEWS

S902 ISOMETRIC VIEWS

04 - ARCHITECTURAL

A001 GENERAL NOTES AND LEGENDS (W/O PROJECT MANUAL)

A003 WALL TYPES

AD101 FIRST FLOOR DEMOLITION PLAN

AD103 ROOF DEMOLITION PLAN

AD201 EXTERIOR DEMOLITION ELEVATIONS

A101 FIRST FLOOR PLAN

A102 ENLARGED PLANS

A103 ROOF PLAN

A141 FIRST FLOOR FINISH PLAN

A201 EXTERIOR ELEVATIONS

A321 WALL SECTIONS

A322 WALL SECTIONS

A323 WALL SECTIONS

A421 INTERIOR ELEVATIONS

A601 SCHEDULES, DOOR AND WINDOW DETAILS

05 - MECHANICAL

M000 MECHANICAL LEGEND SHEET

MD101 LEVEL 1 MECHANICAL DEMOLITION PLAN

M101 1ST FLOOR HVAC PLAN

M111 1ST FLOOR HYDRONIC PIPING PLAN

M120 ROOF MECHANICAL PLAN

M500 MECHANICAL DETAILS

M600 HVAC SCHEDULES

06 - PLUMBING

P000 PLUMBING LEGEND SHEET

PD101 LEVEL 1 PLUMBING DEMOLITION PLAN

P101 LEVEL 1 PLUMBING PLAN

P110 ROOF PLUMBING PLAN

P600 PLUMBING SCHEDULES

08 - ELECTRICAL

E001 LEGEND

ED101 ELECTRICAL DEMOLITION PLAN

E101 FIRST FLOOR POWER PLAN

E201 LIGHTING PLAN

E601 DIAGRAMS

E801 SCHEDULES

E802 SCHEDULES

NTSSCALE :2 Site Map N

DATE DESCRIPTION

BUILDING CODE SUMMARY

PROJECT NAME:

PROJECT INFORMATION:

PROJECT NUMBER:

PREPARED BY:

DATE:

CHECKED BY:

DATE:

APPLICABLE CODES:

BUILDING CODE 2015 MICHIGAN BUILDING CODE (MBC)

EXISING BUILDING CODE: 2015 MICHIGAN REHABILITATION CODE

FIRE CODE: 2015 INTERNATIONAL FIRE CODE (IFC)

PLUMBING CODE: 2015 MICHIGAN PLUMBING CODE (MPC)

MECHANICAL CODE: 2015 MICHIGAN MECHANICAL CODE (MMC)

ELECTRICAL CODE: NFPA 70-2017, NATIONAL ELECTRIC CODE(NEC)

ACCESSIBILITY: PER 2015 MBC CHAPTER 11 AND, ICC A117.1-2009

ENERGY CODE: 2015 MICHIGAN ENERGY CODE

ALMA ARMORY RENOVATION

511/21325.CAK

DPL

01/19/2022

AG

01/19/2022

REHABILITATION OF EXISTING STRUCTURES:

REPAIRS

PER THE NJ SUB CODE

RENOVATIONS:

CHANGES IN USE:

FORMER OCCUPANCY CLASSIFICATION(S):

NEW OCCUPANCY CLASSIFICATION(S):

PARTIAL CHANGE OF OCCUPANCY: YES NO

ADDITIONS

IF YES: SEPARATED NOT SEPARATED

ALTERATIONS:

RECONSTRUCTION:

SEPARATED ADDITION: YES NO

IF YES, FIRE RESISTENCE RATING:

HISTORIC BUILDINGS

BASIC AND SUPPLEMENTAL OCCUPANCY

REQUIREMENTS:

FIRE WALL

FIRE BARRIER

HR

HR

X

X

X X

X

SINGLE

MIXED OCCUPANCY

IF SEPARATED, FIRE RESISTANCE RATING OF FIRE BARRIER:

OCCUPANCY CLASSIFICATION(S):

USES:

OCCUPANCY CLASSIFICATION:

HR

(CHAPTERS 3)

(TABLE 508.4)

SEPARATED COMBINATIONNON-SEPARATED

ASSEMBLY, STORAGE, OFFICE

A-3, B (AREA OF WORK), S-2

X X

AUTOMATIC SPRINKLER SYSTEM PROVIDED THROUGHOUT BUILDING:

YES

13R

NO

13NFPA STANDARD:

PARTIAL/LIMITED-AREA SPRINKLER SYSTEM:

YES NO

BASEMENT SPRINKLED ONLY

X

X

CONSTRUCTION TYPE:

REQUIRED PROVIDED

STRUCTURAL FRAME

BEARING WALLS

NON-BEARING WALLS

NON-BEARING WALLS

FLOOR CONSTRUCTION

ROOF CONSTRUCTION

SECTION

(TABLE 601)

(TABLE 601)

(TABLE 602)

(TABLE 601)

(TABLE 601)

(TABLE 601)

(EXTERIOR)

(INTERIOR)

(EXTERIOR)

BEARING WALLS (TABLE 601)(INTERIOR)

FIRE RESISTANCE OF BUILDING ELEMENTS:

(CHAPTER 6)

BUILDING ELEMENTS

SECTION 601

HT

1/HT

HT

HT

HT

NA

NA

NA

NA

HT

1HT NA

IV (DRILL HALL)

HEIGHT & AREA - ALLOWABLE:

PER TABLE 504.3, 504.4 AND 506.3

sf

OCCUPANCY

CLASSIFICATION

TABULAR AREA At

PER FLOOR

TABULAR HEIGHT

FEET STORIES

ft

(CHAPTER 5)(AREA OF WORK)

B 55 323,000

HEIGHT & AREA - ACTUAL:

BUILDING AREA

SUMMARY

BASEMENT

FIRST

NEW

sf sf

(CHAPTER 5)

EXISTING ADDITION TOTAL

sf sf sf sf sf sf

BUILDING HEIGHT HEIGHT IN FEET HEIGHT IN STORIES

ftPROPOSED ADDITION EXISTING ft

12 1

2,518 19,696 620 20,316

INTERIOR FINISH:

WALL AND CEILING

LOCATION

(CHAPTER 8)

FINISH CLASS

A EXITS CORRIDORS/ EXIT ACCESS ROOMS/ SPACES

B EXITS CORRIDORS/ EXIT ACCESS ROOMS/ SPACES

C EXITS CORRIDORS/ EXIT ACCESS ROOMS/ SPACES

OCCUPANCY:

X X

X X

X

B

FIRE PROTECTION SYSTEMS:

SIZE AND LOCATION OF FIRE AREAS INDICATED ON CODE COMPLIANCE DRAWING(S)

FIRE PROTECTION SYSTEM REQUIRED PROVIDED SECTION

AUTOMATIC SPRINKLER

ALT. AUTOMATIC FIRE-EXTINGUISHING SYST

STANDPIPE

PORTABLE FIRE EXTINGUISHER

FIRE ALARM & DETECTION

EMERGENCY ALARM

SMOKE CONTROL SYSTEM

SMOKE & HEAT VENTS

(903) (904) (905) (906) (907) (908) (909) (910)

FIRE COMMAND CENTER (911)

(CHAPTER 9)

FIRE DEPARTMENT CONNECTIONS (912)

FIRE PUMP (913)

EMERGENCY RESPONDER SAFETY (914)

CARBON MONOXIDE DETECTION (915)

GAS DETECTION (916)

MASS NOTIFICATION SYSTEMS (917)

EMERGENCY RESPONDER RADIO (918)

Y N N Y Y N N N

Y N N Y Y N N N

N N N N N N N N N N N N N N N N

MEANS OF EGRESS:

DESIGN OCCUPANT LOAD SUMMARY

(CHAPTER 10)

MEANS OF EGRESS ELEMENT REQUIRED PROVIDED SECTION

NUMBER OF EXITS

EXIT ACCESS TRAVEL DISTANCE

DEAD-END LIMIT

COMMON PATH OF TRAVEL LIMIT

(TABLE 1006.3.2)

(TABLE 1017.2)

(1020.4) (1006.2.1)

EGRESS WIDTH

PROVIDED SECTION

STAIRS

(TABLE 1005.3.1)

(1009.3)

(TABLE 1005.3.2)

(1007.1.1)

DOORS/OTHER

FIRST FLOOR

REQUIRED

X OCCUPANTS =

X X

BASEMENT

OCCUPANTS =

OCCUPANTS =

FIRST FLOORBASEMENT

BASEMENT

CORRIDOR FIRE-RESIST. RATING (TABLE 1020.1)

OCCUPANCY

63 115

2 6 200' 142'-6"

0.3 18.9

96"

0.2 12.6 23 360"0.2

A-3 60 54B 3 19S-2

CONSTRUCTION TYPE:

REQUIRED PROVIDED

STRUCTURAL FRAME

BEARING WALLS

NON-BEARING WALLS

NON-BEARING WALLS

FLOOR CONSTRUCTION

ROOF CONSTRUCTION

SECTION

(TABLE 601)

(TABLE 601)

(TABLE 602)

(TABLE 601)

(TABLE 601)

(TABLE 601)

(EXTERIOR)

(INTERIOR)

(EXTERIOR)

BEARING WALLS (TABLE 601)(INTERIOR)

FIRE RESISTANCE OF BUILDING ELEMENTS:

(CHAPTER 6)

BUILDING ELEMENTS

SECTION 601

0 0

IIB

ST

AT

E O

F M

IC

HI

GA

N

D E P A R

TM

E N T

O F

TE

C H N O

LO

G Y M A N A G E M E N T

A N D

B U D G E T

FA

C

IL

IT

IE

S

A N D

B U S

IN

E S S

S E R V

IC

E S

A D M

IN

IS

TR

A

TI

O N

A D A M

LA

C H R A D

IR

E C

TO

R

DE

SI

G

N

AN

D

CO

NS

TR

UC

TI

O N

DI

VI

SI

O

N

AL

M A

AR

M

O R

Y R

EN

O

VA

TI

O N

DE

PA

RT

M

EN

T

O F

M

IL

IT

AR

Y

AN

D

VE

TE

RA

NS

AF

FA

IR

S

S.

ST

AT

E

ST

.A

LM

A, M

IC

HI

GA

N

D E S

IG

N E D

D R A W N

C H E C K E D

A P P R O V E D

D A

TE

IS

SU

ED

FO

R P R E

LI

M

IN

A R Y

C O N S

TR

U C

TI

O N

F

IN

A L R E C O R D

ID

EN

TI

FI

C

AT

IO

N

N O

P R O

JE

C T

1/

5.

CA

K

IN

D E X

C O D E

S H

EE

T

DP

L

DP

L

DP

L

XX

X 1/

G0

FD

FD

DN

DN

D

IS

TA

N

C E

2' -6

CPET

EATD

AD

DI

TI

ON

ADDITION

EXISTING 2 HR

RATED WALLS

EXISTING 2 HR

RATED WALLS

EXISTING 2 HR

RATED WALLS

FIRE AREA 'C'

FIRE AREA 'E'

FIRE AREA 'A'

FIRE AREA 'B'

EXISTING 2 HR

RATED WALLS

FIRE AREA 'D'

S-2 2,883 SF

A-3 5,739 SF

S-2 2,646 SF

B 409 SF

B 813 SF

B 1,365 SF

B 1,649 SF

B 1,341 SF

B 105 SF

OCCUPANTS

112 OCCUPANTS

(31 BASEMENT)

OCCUPANTS

OCCUPANTS

OCCUPANTS

OCCUPANTS

(BASEMENT)

1. APPLICABLE CODES:

A. WORK SHALL CONFORM TO FEDERAL, STATE AND LOCAL

CODES AS INTERPRETED BY THE AUTHORITY HAVING

JURISDICTION.

B. CONSTRUCTION SHALL CONFORM TO CURRENT EDITIONS

OF THE MICHIGAN BUILDING CODE: 2010 AMERICANS

WITH DISABILITIES ACT (ADA) STANDARDS FOR

ACCESSIBLE DESIGN (28 CFR PART 36, SUBPART D), 2009

ACCESSIBILITY AND USABLE BUILDINGS AND FACILITIES

(ICC A117.1-2009), AS WELL AS WITH OTHER LOCAL, STATE

AND FEDERAL CODES AND REGULATIONS APPLICABLE TO

THIS PROJECT.

2. COMPLIANCE:

A. PROVIDE FIRE EXTINGUISHERS IN CONFORMANCE WITH

THE FIRE CODE SECTION 906 AND COORDINATE WITH

FIRE MARSHAL PRIOR TO INSTALLATION. DO NOT INSTALL

FIRE EXTINGUISHERS UNTIL LOCATIONS HAVE BEEN

REVIEWED AND APPROVED BY THE AUTHORITY HAVING

JURISDICTION.

B. OBTAIN ALL REQUIRED PERMITS AND PAYMENT OF

PERMIT AND APPLICATION FEES FOR THE WORK.

3. CERTIFICATIONS:

A. THE ARCHITECT'S CERTIFICATION IS ONLY FOR THE WORK

SHOWN TO BE DONE. IT DOES NOT CONSTITUTE

APPROVAL OF PRE-EXISTING CONDITIONS OR REVIEW OF

THOSE CONDITIONS FOR CODE COMPLIANCE.

B. THE ARCHITECT'S CERTIFICATION IS FOR COMPLIANCE

WITH THE BUILDING CODE OF MICHIGAN AND ITS VARIOUS

REFERENCE STANDARDS, FOR PURPOSES OF OBTAINING

A BUILDING PERMIT THROUGH THE AUTHORITY HAVING

JURISDICTION AND TO CONVEY CONSTRUCTION

REQUIREMENTS FOR THE PROJECT. CERTIFICATION DOES

NOT GUARANTEE COMPLIANCE WITH LOCAL CODES THAT

MAY APPLY.

GENERAL NOTES

OCCUPANCY GROUP

# OCCUPANTS

S.F.

LEGEND

EXIT SIGN

EXIT

COMMON PATH OF EGRESS DISTANCE

EXIT ACCESS TRAVEL DISTANCE

(ALONG STAIRWAY NOSING AT OPEN

STAIRWAYS)

FIRE EXTINGUISHER ON WALL BRACKET

FIRE EXTINGUISHER CABINET

1-HR RATED WALL

2-HR RATED WALL

1-HR. RATED FLOOR/BEAM/COLUMN

TO SUPPORT RATED ELEVATOR

SHAFT & MACHINE ROOM ENCLOSURE

FEC

FE

DF DRINKING FOUNTAIN

SS SERVICE SINK

SIGN DIRECTION

FACE OF SIGN

ST

AT

E O

F M

IC

HI

GA

N

D E P A R

TM

E N T

O F

TE

C H N O

LO

G Y M A N A G E M E N T

A N D

B U D G E T

FA

C

IL

IT

IE

S

A N D

B U S

IN

E S S

S E R V

IC

E S

A D M

IN

IS

TR

A

TI

O N

A D A M

LA

C H R A D

IR

E C

TO

R

DE

SI

G

N

AN

D

CO

NS

TR

UC

TI

O N

DI

VI

SI

O

N

AL

M A

AR

M

O R

Y R

EN

O

VA

TI

O N

DE

PA

RT

M

EN

T

O F

M

IL

IT

AR

Y

AN

D

VE

TE

RA

NS

AF

FA

IR

S

S.

ST

AT

E

ST

.A

LM

A, M

IC

HI

GA

N

D E S

IG

N E D

D R A W N

C H E C K E D

A P P R O V E D

D A

TE

IS

SU

ED

FO

R P R E

LI

M

IN

A R Y

C O N S

TR

U C

TI

O N

F

IN

A L R E C O R D

ID

EN

TI

FI

C

AT

IO

N

N O

P R O

JE

C T

1/

5.

CA

K

IN

D E X

C O D E

S H

EE

T

DP

L

DP

L

DP

L

XX

X 1/

G0

SCALE : 1/8" = 1'-0"

1 CODE COMPLIANCE DIAGRAM - FIRST FLOOR

N

00894964Arch_Alma Armory_2021_rgibb2TNFS

File details come from the government source that posted it. Updated .