511-21325CAK_02 Civil_2.pdf

PDF 4 MB Posted

Attached to
511/21325. CAK; Alma Armory - Renovate Armor
Solicitation number
RFQ - 171 - 230000000729
Issued by
Gratiot County, Allendale CDP, Michigan

About this file

This document contains civil engineering drawings and details for the Alma Armory Renovation project in Alma, Michigan, which is being undertaken by the State of Michigan Department of Technology, Management and Budget, Facilities and Business Services Administration. The drawings provide information on the underground utilities, soil erosion and sediment control, pavement details, and other civil site work required for the renovation of the existing armory facility. The project is located in Gratiot County and the Allendale Census Designated Place. The document includes an add alternate to construct a storm manhole and replace approximately 40 linear feet of existing storm pipe. Contractors are instructed to field verify the location and elevation of existing utilities prior to commencing construction and to notify the owner of any discrepancies.

The document does not provide details on pricing, funding sources, or set-asides. Contractors are instructed to submit bids through the State's online SIGMA VSS system, and are advised to contact the project manager with any questions or issues related to the electronic submission process.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8/

/2

8:

A

M O

:\S ta te o f M ich ig an

\0

9.

S ta te o f M ich ig an D

TM

B-

Al m a Ar m or y Re no v\

4.

Dw gs

\4 .1

C ivi l\C

SE

CS

D

ET

AI

LS

.d wg

KAB'17

KNOW WHAT'S BELOW.

CALL BEFORE YOU DIG.

ST

AT

E O

F M

IC

HI

G

AN

D

EP

A R

TM

EN

T O F

TE

C H N O

LO

G Y M A N A G

EM

EN

T A N D B

U D G

ET

FA

C

IL

IT

IE

S A

N D B

U S

IN

ES

S S

ER

V

IC

ES

A D M

IN

IS

TR

A

TI

O N

A D A M L A C H R A D

IR

EC

TO

R

DE

SI

G N

AN

D

CO

NS

TR

UC

TI

O

N

DI

VI

SI

O N

AL

M

A

AR

M O

R Y

R

EN

O

VA

TI

O

N

DE

PA

RT

M

EN

T O

F M

IL

IT

AR

Y

AN

D

VE

TE

RA

NS

A

FF

AI

RS

AL

M

A, M

IC

HI

G

AN

D E S

IG

N E D

D R A W N

C H E C K E D

A P P R O V E D

D

AT

E

IS

SU

ED

FO

R

P R E

LI

M

IN

A R Y

C O N S

TR

U C

TI

O N

FI

N A L R E C O R D

ID

EN

TI

FI

C

AT

IO

N

N O

P R O

JE

C T

1/

5.

CA

K

IN

D E X

C O D

EY2

SH

EE

T

JA JA PA

F

PA

F

C3

SOIL EROSION AND

SEDIMENT CONTROL DETAILS

/2

1/

T

SAN C.O. PER

DETAIL A4/C700

INV=757.30

SAN C.O. PER

DETAIL A4/C700

INV=755.93

SAN C.O. PER

DETAIL A4/C700

INV=756.71

SAN C.O. PER

DETAIL A4/C700

INV=755.27

STORM C.O.

INV=756.45

HA

W

TH

O

RN

E

ST

EXISTING BUILDING

F.F. = 761.56'

EXISTING BUILDING

F.F. = 760.3'

L

F 6"

S

AN

S

EW

.0

12 LF 6" SAN SEW. @ 1.0%

!!CAUTION!!

UTILITY CROSSING

L

F 6"

S

AN

S

EW

.0

78 LF 6" SAN SEW. @ 1.0%59 LF 6" SAN SEW. @ 1.0%

7 LF 6" SAN SEW. @ 1.0%

PROPOSED

UNDERGROUND

ELECTRICAL LINE

(BY OTHERS).

APPROXIMATE LOCATION OF NEW

COMMUNICATIONS PEDESTAL MOUNTED

NEXT TO BUILDING (BY OTHERS). ROUTE

WIRING ALONG BUILDING INTO EXISTING

COMMUNICATION CONDUITS

17 LF 6" HDPE

ST SEW. @ 1.00%

!!CAUTION!!

UTILITY CROSSING

!!CAUTION!!

UTILITY CROSSING APPROXIMATE LOCATION OF NEW

UTILITY POLE WITH

TRANSFORMERS. TRENCH WILL BE

1'-2' WIDE AND 2'-3' DEEP BY

CONSUMERS ENERGY.

CONTRACTOR TO COORDINATE

WORK WITH CONSUMERS.

APPROXIMATE LOCATION OF NEW

UTILITY POLE . CONTRACTOR TO

COORDINATE WORK WITH CONSUMERS

6" SAN. LEAD CONNECTION TO THE

BLDG. SEE PLUMBING PLANS FOR

EXACT LOCATION

INV. = 755.86

COMMUNICATION ROUTED ALONG

BUILDING

CONNECT PROPOSED 6" SANITARY

SERVICE TO EXISTING 6" SANITARY

VIA WYE. CONTRACTOR FIELD VERIFY

EXACT LOCATION AND ELEVATION OF

EXISTING SAN. SEWER BEFORE COMMENCING

CONSTRUCTION AND NOTIFY THE ENGINEER

OF ANY DISCREPANCIES.

INV=754.3±

6" TOP SAN. = 755.00

6" STORM INV. 755.32

CONTRACTOR FIELD VERIFY EXISTING STORM

SEWER ELEVATION AND NOTIFY THE

ENGINEER OF ANY DISCREPANCIES.

CONSTRUCT PROP. ST CB #1

OVER THE EXISTING 12" STORM

RIM=760.72

INV IN:755.25 W 12"

INV IN:755.75 S 6"

INV OUT:755.25 E 12"

ALTERNATE 1

CONSTRUCT PROP. ST CB #2

OVER THE EXISTING 12" STORM

RIM=760.32

INV IN:755.21 W 12"

INV OUT:754.96 E 12"

ALTERNATE 1

40 LF 12" HDPE

ST SEW. @ 0.10%

CONNECT ROOF DRAIN TO

PROPOSED STORM SEWER. SEE

PLUMBING PLANS FOR EXACT

LOCATION AND ELEVATION

INV=756.62

6" SAN. LEAD CONNECTION TO THE

BLDG. SEE PLUMBING PLANS

FOR EXACT LOCATION

INV=757.4

L

F 6"

H

DP

E

ST

S

EW

.0 0%

SAN C.O. PER

DETAIL A4/C700

INV=754.64

UTILITY NOTES:

1. ALL WORKMANSHIP, MATERIALS, AND CONSTRUCTION PRACTICES SHALL

CONFORM TO THE REQUIREMENTS OF THE OWNER OR THE AGENCY HAVING

JURISDICTION OVER THE APPLICABLE UTILITY.

2. CONTRACTOR IS RESPONSIBLE FOR REPAIRS OF DAMAGE TO ANY EXISTING

UTILITY DURING CONSTRUCTION AT NO COST TO THE OWNER.

3. ALL FILL MATERIAL IS TO BE IN PLACE, AND COMPACTED BEFORE

INSTALLATION OF PROPOSED UTILITIES.

4. CONTRACTOR SHALL NOTIFY THE UTILITY COMPANIES 72 HOURS BEFORE

CONNECTING TO ANY EXISTING LINE.

5. IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATERLINES, SANITARY

LINES, STORM LINES AND GAS LINES (EXISTING AND PROPOSED), THE

CONTRACTOR SHALL NOTIFY THE ENGINEER AS SOON AS THE CONFLICT IS

DISCOVERED.

6. TOPS OF EXISTING UTILITY STRUCTURES SHALL BE ADJUSTED TO FINISHED

GRADE.

7. EXISTING UTILITIES SHALL BE VERIFIED IN FIELD PRIOR TO INSTALLATION OF

ANY NEW LINES.

8. CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE CONSTRUCTION

REQUIREMENTS OF THE UTILITY OWNERS.

9. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR

ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON

RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE,

MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE

RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL

THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY

EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE

THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING

UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON

THE PLANS.

10. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS

FOR ACTUAL LOCATION AND ELEVATIONS OF ALL UTILITY ENTRANCES TO

INCLUDE SANITARY SEWER LATERALS, DOMESTIC AND FIRE PROTECTION

WATER SERVICE, ELECTRICAL, TELEPHONE, AND GAS SERVICE. CONTRACTOR

SHALL COORDINATE INSTALLATION OF UTILITIES, IN SUCH A MANNER AS TO

AVOID CONFLICTS AND ASSURE PROPER DEPTHS ARE ACHIEVED AS WELL. AS

COORDINATING WITH UTILITY REQUIREMENTS AS TO LOCATION AND

SCHEDULING FOR TIE-INS/CONNECTIONS PRIOR TO CONNECTING TO EXISTING

UTILITIES.

11. THE CONTRACTOR SHALL CONDUCT ALL REQUIRED TESTS TO THE

SATISFACTION OF THE RESPECTIVE UTILITY COMPANIES AND THE OWNER'S

INSPECTING AUTHORITIES.

12. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING PIPE SIZES AND INVERTS

ELEVATIONS BEFORE ORDERING MANHOLE AND CATCH BASIN STRUCTURES.

13. ALL UTILITIES BELOW PAVED AREAS SHALL BE BACKFILLED WITH 100%

GRANULAR MATERIAL (OR APPROVED OTHER) AND COMPACTED TO 95% OF

ITS MAXIMUM UNIT WEIGHT.

14. ALL RIM ELEVATIONS IN OUTLAWN AREAS ARE APPROXIMATE ONLY AND

SHALL BE ADJUSTED BY THE CONTRACTOR AFTER FINAL GRADES ARE

ESTABLISHED.

UTILITY LEGEND:

STORM SEWER

YARD BASIN

CATCH BASIN

SANITARY SEWER

CLEANOUT

UTILITY CROSSING

SANITARY SEWER MANHOLE

STORM MANHOLE

0 30 60 90 FT

1" = 30' SCALE BAR

8/

/2

8:

A

M O

:\S ta te o f M ich ig an

\0

9.

S ta te o f M ich ig an D

TM

B-

Al m a Ar m or y Re no v\

4.

Dw gs

\4 .1

C ivi l\C

UT

IL

IT

Y

PL

AN

.d wg

KAB'17

KNOW WHAT'S BELOW.

CALL BEFORE YOU DIG.

ST

AT

E O

F M

IC

HI

G

AN

D

EP

A R

TM

EN

T O F

TE

C H N O

LO

G Y M A N A G

EM

EN

T A N D B

U D G

ET

FA

C

IL

IT

IE

S A

N D B

U S

IN

ES

S S

ER

V

IC

ES

A D M

IN

IS

TR

A

TI

O N

A D A M L A C H R A D

IR

EC

TO

R

DE

SI

G N

AN

D

CO

NS

TR

UC

TI

O

N

DI

VI

SI

O N

AL

M

A

AR

M O

R Y

R

EN

O

VA

TI

O

N

DE

PA

RT

M

EN

T O

F M

IL

IT

AR

Y

AN

D

VE

TE

RA

NS

A

FF

AI

RS

AL

M

A, M

IC

HI

G

AN

D E S

IG

N E D

D R A W N

C H E C K E D

A P P R O V E D

D

AT

E

IS

SU

ED

FO

R

P R E

LI

M

IN

A R Y

C O N S

TR

U C

TI

O N

FI

N A L R E C O R D

ID

EN

TI

FI

C

AT

IO

N

N O

P R O

JE

C T

1/

5.

CA

K

IN

D E X

C O D

EY2

SH

EE

T

JA JA PA

F

PA

F

C4

UNDERGROUND COMMUNICATION

UNDERGROUND ELECTRIC

ADD ALTERNATE:

1. CONSTRUCT STORM MH 2 OVER EXISTING STORM PIPE. REMOVE

AND REPLACE APPROXIMATE 40 LF OF EXISTING PIPE AT 0.1%

SLOPE TO AVOID CONFLICT WITH THE PROPOSED SANITARY. THIS

ALTERNATE MAY BE USED IN THE EVENT OF CONFLICT BETWEEN

STORM SEWER AND SANITARY SEWER.

NOTE:

1. CONTRACTOR TO NOTE THAT LOCATIONS AND ELEVATIONS OF

EXISTING UTILITIES (PARTICULARLY STORM AND SANITARY

SERVICES WHERE THEY EXIT THE BUILDING) ARE BASED ON FIELD

INVESTIGATION AND INFORMATION FROM RECORD PLANS.

LOCATIONS AND ELEVATIONS ON THIS DRAWING ARE SHOWN IN

APPROXIMATE LOCATIONS ONLY BASED ON THE LIMITED

INFORMATION AVAILABLE. CONTRACTOR MUST FIELD VERIFY

LOCATION AND ELEVATIONS OF UTILITIES PRIOR TO

COMMENCING CONSTRUCTION AND MUST NOTIFY THE OWNER OF

DISCREPANCIES THAT MAY IMPACT PROPOSED IMPROVEMENTS

AS SHOWN ON PLANS.

UTILITY PLAN

/2

1/

EXPANSION JOINT

WITH JOINT FILLER

CONTRACTION JOINT

21 12 2 2

WIDTH VARIES (REFER TO PLAN)

25' MAX.

5', TYP.

6"

2% MAX.

4" MDOT CLASS II

GRANULAR

MATERIAL

COMPACTED

SUBGRADE

4" THICK 3500 PSI CONC.

(6" THICK THROUGH

DRIVEWAYS)

A2 CONCRETE SIDEWALK DETAIL

N.T.S.

2" HMA, 36A WEARING COURSE

2" HMA, 3B LEVELING COURSE

EXISTING AGGREGATE BASE

A1 HMA PAVEMENT SECTION

N.T.S.

1' ANTI-CLIMB ARM WITH 3 SETS OF

DOUBLE STRAND BARBED WIRE

KAB'17

KNOW WHAT'S BELOW.

CALL BEFORE YOU DIG.

ST

AT

E O

F M

IC

HI

G

AN

D

EP

A R

TM

EN

T O F

TE

C H N O

LO

G Y M A N A G

EM

EN

T A N D B

U D G

ET

FA

C

IL

IT

IE

S A

N D B

U S

IN

ES

S S

ER

V

IC

ES

A D M

IN

IS

TR

A

TI

O N

A D A M L A C H R A D

IR

EC

TO

R

DE

SI

G N

AN

D

CO

NS

TR

UC

TI

O

N

DI

VI

SI

O N

AL

M

A

AR

M O

R Y

R

EN

O

VA

TI

O

N

DE

PA

RT

M

EN

T O

F M

IL

IT

AR

Y

AN

D

VE

TE

RA

NS

A

FF

AI

RS

AL

M

A, M

IC

HI

G

AN

D E S

IG

N E D

D R A W N

C H E C K E D

A P P R O V E D

D

AT

E

IS

SU

ED

FO

R

P R E

LI

M

IN

A R Y

C O N S

TR

U C

TI

O N

FI

N A L R E C O R D

ID

EN

TI

FI

C

AT

IO

N

N O

P R O

JE

C T

1/

5.

CA

K

IN

D E X

C O D

EY2

SH

EE

T

FINISHED GRADE

FROM BUILDING

CLEAN-OUT COVER

NOTES:

1. IT IS RECOMMENDED THAT ALL SOLVENT WELD JOINTS BE MADE AS FOLLOWS:

· CLEAN DRY HUBS AND SPOTS

· PRIMER APPLIED TO PARTS BEING CONNECTED

· PVC SOLVENT WELD CEMENT APPLIED DIRECTLY OVER PRIMER

· PVC TYPE I IS COMPATIBLE FOR SOLVENT WELDING TO SDR-21 OR ANY

OTHER PVC TYPE I PIPE MADE TO "STEEL PIPE" OUTSIDE DIMENSIONS

2. FILL SHALL BE PLACED IN 6" LIFTS AND TAMPED AFTER EACH LIFT.

6" 45° 1/8 LONG SWEEP BEND

LATERAL RISER - SCH 40 (ASTM

D-2665) OR SDR-21 (ASTM D-2441)

PROVIDE CAST IRON CLEAN-OUT

PLUG IP THD BRASS SCREW PLUG

(HS 67), NO PVC ALLOWED

FINISHED GRADE (PAVED)

1" TO 3"

CLEARANCE

PVC FEMALE ADATOR, IP THD X

SOCKET

17"

1"

7-1/2"

10"

BEDDING MATERIAL

TO SEWER

LATERAL

GLUED JOINT, TYP.

PVC WYE (TEES NOT ALLOWED)

EAST JORDAN IRON WORKS OR

APPROVED EQUAL FRAME AND COVER

INSTALLED FLUSH WITH FINISHED

GRADE - TO BE USED IN PAVED AREAS

ONLY

PIPE BACKFILL; REFER TO "TRENCH

AND RESTORATION DETAIL"

CLEANOUT COVER TO BE MARKED

WITH THE WORD "SEWER"

10"Ø

A4 SANITARY SEWER LATERAL CLEAN-OUT

N.T.S.

A3 ANTI-CLIMB LOCKABLE GATE DETAIL

N.T.S.

JA JA PA

F

PA

F

C7

AA

REMOVE AND REPLACE 4" OF EXISTING

MATERIAL, PROOF-ROLLING THE

UNDERLAYING AGGREGATE AND

REMOVE AND REPLACE UNSUITABLE

MATERIAL

NOTES:

1. ALL POSTS SHALL BE PLUMB

2. WELD ALL PIPE CONNECTIONS.

3. GATE FABRIC TO MATCH FENCE

FABRIC. PROVIDE MATCHING

POST CAPS WHERE REQUIRED.

4. NOTCH CURBS TO MAINTAIN 4"

HEIGHT BETWEEN BOTTOM OF

GATE AND PAVING.

5. PROVIDE EMBEDDED METAL

SLEEVE AND HOLD OPEN FOR

EACH LEAF OF GATE.

12"

6'

4'-0" MIN.

4" MIN.

4"

6 5/8"Ø GATE POST FOR 10' - 15' WIDE

GATE, 4"Ø PIPE FOR 6' - 10' GATE,

AND 3"Ø PIPE FOR UP TO 6' WIDE

GATE

6"

8"

2 1/2"Ø SCHED. 80 TOP AND BOTTOM

RAIL ON GATES

STANDARD OFFSET TYPE HINGES

2 1/2"Ø SCHED. 80 TOP AND BOTTOM

RAIL ON GATES, TYP.

2"Ø SCHED. 40 FOR VERTICAL

MEMBERS, TYP.

1 5/8"Ø SCHED. 40 FOR DIAGONAL

MEMBERS

1"Ø PLUNGER ROD AND GUIDE, BOTH

SIDES

PLUNGER CATCH

CONCRETE BASE

REFER TO CHAIN LINK FENCE DETAIL

8'

GALVANIZED 2-3/8" O.D. LINE POST W/

CAP

LATCH ASSEMBLY

DETAILS

/2

1/

File details come from the government source that posted it. Updated .