AE601_2023.01.18.pdf
PDF 619 KB Posted
- Attached to
- Lobby Security Upgrades Keating Federal Building Construction Project Federal contract opportunity
- Solicitation number
- 47PC0222R0025
About this file
This solicitation is for a lobby security upgrades construction project at the Kenneth B. Keating Federal Building in Rochester, New York. The General Services Administration is seeking bids for base work including modifications to planters, security fences, columns, entrances, curtain walls, pavements, and mechanical, electrical and plumbing systems to renovate the building lobby. A pre-bid site visit will be held on May 11th and questions are due by May 18th, with bids due by June 1st. The project scope involves furnishing all materials, equipment, labor and supervision to perform renovations including structural hardening, a temporary public entrance, an air lock vestibule with revolving doors, a protected path for public access, and construction of a security station, gun locker and storage room.
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
3 4 5 6 7
J
H
G
F
128 SF
STORAGE
1205H
92 SF
GUN LOCKER
1205B
205 SF
EX. FPS ROOM
292 SF
STAIRWELL
VESTIBULE
1205G
103 SF
SECURITY
STATION
1205C
931 SF
PUBLIC ENTRY
LOBBY
1205D
63 SF
EXIT VESTIBULE
1025E
63 SF
ENTRY
VESTIBULE
1025F
AE200
AE502
EX. STAIR #3
AE502
Sim
AE601
= APPROXIMATE AREA OF TERRAZZO FLOORING TO BE INSTALLED
= APPROXIMATE AREA OF EXISTING TERRAZZO TO REMAIN INTACT
= ENTRANCE FLOOR GRILLE
= SEALED CONCRETE
ETR CMU WALL
SCHEDULED CEILING GRILLE
7/8" FURING
CHANNEL
3/4" FRT
PLYWOOD WITH
PLAM1 FINISH
SCHEDULED
WALL BASE
NKB
N. .______________________________________________________
ARCHITECTURE & ENGINEERING, PC..
K BHANDARI
RENOVATION
SHEET SIZE: 34 X 44
DRAWING NO.
CHECKED BY
DRAWN BY
FLOOR NO.
FILE NAME
DRAWING TITLE
SUB. DATE
SUBMISSION
GSA PM
PROJECT NO.
PROJECT
DESCRIPTION
PROJECT
TITLE
FACILITY CODE
OTHER
BUILDING NOs.
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
CONSTR. FIRM
SUB A/E
PRIME A/E
A/E CON. NO.
D R
A W
IN
G
P R
O J E
C T
B U
IL
D
IN
G
C O
N T
R A
C T
O R
S G
R A
P H
IC
S C
A L
E R
E V
IS
IO
N N
O T
E S
C E
R T
IF
IC
A T
IO
N
S
MARK DATE DESCRIPTION
SHEET OF
NK BHANDARI ARCHITECTURE
C&S ENGINEERS
GS-07-P-16-UC-D-7008
K E
Y P
L A
N
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
DATE:
A
SUB A/E
CONSTR. CON. -
NYS EDUCATION LAW, SECTION 7209 AND 69.5(B)
PROHIBITS ANY PERSON TO ALTER THESE DRAWINGS
OTHER THAN A LICENSED ARCHITECT OR THE DESIGN
ENGINEER. INFORMATION ON THESE DRAWINGS FOR
GSA ONLY, AND CAN BE UTILIZED BY GSA AS THEY
DEEM NECESSARY.
COPYRIGHT 2022
N. K. BHANDARI, ARCHITECTURE & ENGINEERING, P.C.
1005 W. Fayette Street, Suite 500 Syracuse, NY 13204
Phone Fax www.nkbpc.com
315.428.1177 315.428.9822
499 Col. Eileen Collins Blvd Syracuse, NY 13212
Phone www.cscos.com
315.455.2000
U.S. General Services Administration
100 STATE STREET
ROCHESTER, NY 14614
B
C
D
3 4 51
C:\Users\pdd\Documents\R21_16320.xx.126 GSA Keating Lobby Security - Design_CENTRAL_pdudkowskiD8JHD.rvt
/1
/2
:5 :4
P
M
INTERIOR FINISH PLAN AND
SCHEDULES
LOBBY SECURITY UPGRADES
PDD
EAB 3/11/2022
RWA A5010736
3/11/2022
32 60
FOR CONSTRUCTION
AE601
PETER SMITH
KENNETH B. KEATING
GENERAL FINISH NOTES
1 USMS AND COURTS TO REVIEW AND CONFIRM ALL FINISHES.
2 REFER TO REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
3 SEE INTERIOR ELEVATIONS AND DETAILS FOR ADDITIONAL INFORMATION.
4 EXISTING CEMENT TERRAZZO AND THINSET EPOXY TERRAZZO SHALL RECEIVE SEALER
UPON COMPLETION OF WORK. SEALER SHALL COMPLY IN STRICT ACCORDANCE WITH
MANUFACTURER'S WRITTEN OR PUBLISHED INSTRUCTIONS.
5 CONTRACTOR SHALL PROTECT EXISTING TERRAZZO FLOORING AS WELL AS ADJACENT
SURROUNDING AREAS DURING CONSTRUCTION. CONTRACTOR SHALL TAKE PHOTOGRAPHIC
IMAGES OF THE EXISTING TERRAZZO FLOORING PRIOR TO START OF WORK AND SUBMIT
THEM TO THE ARCHITECT FOR RECORD.
6 CONTRACTOR SHALL BE RESPONSIBILE FOR DAMAGE OF EXISTING TERRAZZO FLOORING,
DIVIDER STRIPS, ETC. AS A RESULT OF CONSTRUCTION AND SHALL REPLACE OR REPAIR IN
KIND.
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME AREA
FLOORING CEILINGS WALLS
COMMENTSFLOOR FINISH
BASE
MATERIAL
CEILING
FINISH
WALL FINISH
- NORTH
WALL FINISH
- SOUTH
WALL FINISH -
EAST
WALL FINISH
- WEST
001 STORAGE 155 SF EXIST. - - PNT1 PNT1 PNT1 PNT1
002 VESTIBULE 61 SF EXIST. WB1/EXIST ACP2 PNT1 PNT1 PNT1 PNT1
003 CORRIDOR 119 SF EXIST. WB1/EXIST. ACP2 PNT1 PNT1 PNT1 PNT1
131 EX. STAIR #3 1114 SF EXIST. EXIST. ACP1 EXIST. EXIST. EXIST. EXIST. SEE GENERAL FINISH NOTES FOR
EXIST. FLOORING
1025E EXIT VESTIBULE 63 SF EFG1 - PNT3 - - - -
1025F ENTRY VESTIBULE 63 SF EFG1 - PNT3 - - - -
1205A MAIN LOBBY 2295 SF TERR1 / EXIST. WB1 / EXIST. ACP1 EXIST. / PLAM1 EXIST. / PLAM1 EXIST. WD1 EXISTING SALVAGED MARBLE TO BE
USED ON COLUMNS
1205B GUN LOCKER 92 SF TERR1 / EXIST. WB2 ACP2 PNT1 PNT1 PNT1 PNT1 SEE GENERAL FINISH NOTES FOR
EXIST. FLOORING
1205C SECURITY STATION 103 SF TERR1 / EXIST. - ACP1 PLAM1 / PLAM2 PLAM1 / PLAM2 PLAM1 / PLAM2 PLAM1 / PLAM2 SEE GENERAL FINISH NOTES FOR
EXIST. FLOORING
1205D PUBLIC ENTRY
LOBBY
931 SF TERR1 WB1 ACP1 / PNT3 PLAM1 PLAM1 / EXIST. PLAM1 EXIST. EXISTING SALVAGED MARBLE TO BE
USED ON COLUMNS
1205G STAIRWELL
VESTIBULE
292 SF TERR1 WB1 PNT3 PNT1 PNT1 - PNT1
1205H STORAGE 128 SF CONC1 WB2 ACP1 / PNT3 PNT1 PNT1 PNT1 PNT1
T01 TEMPORARY PUBLIC
ENTRANCE
Redundant Room
EXIST. EXIST. ACP2 PNT1 PNT1 PNT1 PNT1
FINISH LEGEND
MARK SPEC. DESCRIPTION MANUFACTURER SERIES/ MODEL COLOR FINISH COMMENTS
ACP1 09 51 13 ACOUSTIC CEILING PANEL ARMSTRONG LYRA PB VECTOR WHITE - 30"x30" TEGULAR; VECTOR 15/16" EDGE
ACP2 09 51 13 ACOUSTIC CEILING PANEL ARMSTRONG LYRA PB VECTOR WHITE - 24"x24" TEGULAR; VECTOR 15/16" EDGE
CONC1 03 33 00 CONCRETE SEALER MASONRY DEFENDER PENETRATING CLEAR - BREATHABLE SILANE/SILOXANE BLEND
EFG1 12 48 16 ENTRANCE FLOOR GRILLE THE CS GROUP GRIDLINE G6PC 316 STAINLESS STEEL -
MTL1 06 41 16 DECORATIVE METAL TBD - US10A AGED BRONZE 16GA DECORATIVE METAL
PLAM1 06 41 16 PLASTIC LAMINATE TBD TBD TBD - MATCH EXISTING WOOD PATTERNED
PLAM @ ELEVATOR LOBBY
PLAM2 06 41 16 PLASTIC LAMINATE TBD TBD TBD - WHITE
PNT1 09 91 23 PAINT (FIELD) SHERWIN WILLIAMS - MATCH BLDG STANDARD EGGSHELL LOW VOC. USED @ STORAGE AND
STAIR WALLS
PNT2 09 91 23 PAINT (TRIM) SHERWIN-WILLIAMS - MATCH BLDG STANDARD SEMI-GLOSS LOW VOC. USED @ HM DOORS AND
FRAMES
PNT3 09 91 23 PAINT (CEILING) SHERWIN-WILLIAMS SW7007 CEILING WHITE FLAT LOW VOC. USED @ CEILINGS
SSM1 12 36 61.16 SOLID SURFACE CORIAN - DEEP CAVIAR -
TERR1 09 66 23 TERRAZZO TBD EPOXY THINSET MATCH EXIST. TBD SEE GENERAL FINISH NOTES FOR
MORE INFORMATION
WB1 09 62 63 WALL BASE - 4" FLUSH MTL DARK BRONZE ANODIZED COLOR AND FINISH TO MATCH
CURTAINWALL
WB2 09 68 13 WALL BASE - ROPPE - - 4" COVE BASE
1/4" = 1'-0"AD101 AE601
1 FINISH PLAN - FIRST FLOOR
FINISH PLAN - KEYED NOTES - AE601
NUMBER DESCRIPTION
1 THE ENTIRE EXISTING TERRAZZO FLOOR IN THE LOBBY SHALL BE STRIPPED OF
EXISTING SEALER, CLEANED, REFINISHED AND POLISHED TO "LIKE NEW
CONDITION".
2 THE CONTRACTOR SHALL INSPECT ENTIRE EXISTING TERRAZZO FLOOR AND
IDENTIFY AREAS IN NEED OF REPAIR WITH ARCHITECT AND GSA DURING ON SITE
WALK-THRU. UPON REVIEW, CONTRACTOR SHALL REPAIR THE TERRAZZO IN
ACCORDANCE WITH "THE NATIONAL TERRAZZO AND MOSAIC ASSOCIATION, INC."
PUBLISHED RECOMMENDATIONS FOR EXISTING TERRAZZO REPAIR. COLOR,
STYLE AND FINISH SHALL MATCH EXISTING ADJACENT TERRAZZO IN KIND.
CONTRACTOR SHALL PROVIDE MOCK UP FOR ARCHITECT APPROVAL PRIOR TO
PROCEEDING WITH THE WORK.
3 EXTEND DIVIDER STRIPS TO ALIGN WITH EXISTING PATTERN. MATERIAL OF
DIVIDER STRIPS SHALL MATCH EXISTING ADJACENT IN KIND.
4 REVOLVING DOOR FLOOR BY REVOLVING DOOR MANUFACTURER.
FINISH LEGEND
0 2' 4' 8'1 1/2" = 1'-0"AD200 AE601
2 WALL LAMINATE DETAIL
0 1' 2'
2 1/18/23 ADDENDUM NO. 2
. 338 SF .
| Sheets |
| AE600 - SCHEDULES AND DIAGRAMS |
| AE601 - INTERIOR FINISH PLAN AND SCHEDULES |
| G-110 - PHASING PLAN SHEETS |
File details come from the government source that posted it. Updated .