AE600_2023.01.18.pdf

PDF 375 KB Posted

Attached to
Lobby Security Upgrades Keating Federal Building Construction Project Federal contract opportunity
Solicitation number
47PC0222R0025
Issued by
General Services Administration Public Buildings Service Region 2

About this file

This solicitation is for construction services to renovate the lobby of the Kenneth B. Keating Federal Building in Rochester, NY. Work includes modifications to planters, security fences and gates, structural hardening at columns, temporary and permanent entrances, airlock vestibules, curtain walls, concrete work, mechanical and electrical systems, and construction of a security station, gun locker and storage room. A mandatory site visit will be held on May 11th, with questions due by May 18th and bids due June 1st. The solicitation is issued by the General Services Administration for their Public Buildings Service Region 2.

View the file

Other files for this federal contract opportunity

Other files attached to Lobby Security Upgrades Keating Federal Building Construction Project, newest first.
File Type Posted
Solicitation Amendment 47PC0222R0025_0003.pdf PDF
2023.02.07_Pre-BID RFI Responses.pdf PDF
G-110_2023.01.18.pdf PDF
Solicitation_Amendment_47PC0222R0025_0002_(1).pdf PDF
AE601_2023.01.18.pdf PDF
092300 - Gypsum Plastering_2023.01.18.pdf PDF
2023.01.18_Addendum_02.pdf PDF
01 10 00 summary_2023.01.18.pdf PDF
2022.05.25_Addendum_01.pdf PDF
AMENDMENT 0001_Attachment 5 Key Personnel Resume.pdf PDF
Site Visit Sign In Sheet.pdf PDF
2022.05.25_Pre-BID RFI Responses.pdf PDF
Solicitation Amendment 47PC0222R0025_0001.pdf PDF
SBSA GC Agreement_ 47PC0222R0025 Keating Lobby- Construction.pdf PDF
Attachment 3 Experience on Similar Projects Offeror Form.xlsx XLSX spreadsheet
Contractors Qual and Financial Info GSA527-15c.pdf PDF
Bid Bond SF24-16d.pdf PDF
Attachment 5 Key Personnel Resume.pdf PDF
Attachment 6 WD NY20210010.pdf PDF
Attachment 7 SBU Clause and Disposal Form.pdf PDF
GC Reps and Certs_ 47PC0222R0025 Keating Lobby- Construction.pdf PDF
RFP 47PC0222R0025_SF 1442 Form.pdf PDF
Solicitation_ 47PC0222R0025 Keating Lobby- Construction.pdf PDF
Attachment 4 PBS Past Performance Questionnaire.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPE H1

HOLLOW METAL

WELDED FRAME

0' - 2" 0' - 2"

DOOR WIDTH

0' - 1 3/4"DOOR WIDTH

1 3/4"

WIDTH

SIDELITE

1 3/4"

S E

E E

L E

V A

T

IO

N S

/4

/4

/2

TYPE ABL

ALUMINUM BLAST

WELDED FRAME

0' - 1 3/4" 0' - 1 3/4"

DOOR WIDTH

/4

TYPE ABA

ALUMINUM BALLISTIC

WELDED FRAME

0' - 2 1/2" 0' - 2 1/2"

DOOR WIDTH

/2

TYPE A1

ALUMINUM

WELDED FRAME

TYPE A2

ALUMINUM

WELDED FRAME

0' - 1 3/4" 0' - 1 3/4"

DOOR WIDTH

/4

TYPE H2

HOLLOW METAL

WELDED FRAME

0' - 2" 0' - 2"

DOOR WIDTH

TYPE F

FLUSH

NOTES:

1. DOOR TYPES ARE GENERALLY BASED ON STEEL DOOR INSTITUE STANDARD STYLES

2. REFER TO ELEVATIONS FOR GLAZING TYPES AT EACH OPENING.

/2

/2

3 1/2" 2' - 5" 3 1/2"

TYPE B1

UL752 LEVEL 3

ALUM DOUBLE LITE

/2

/2

3 1/2" 2' - 5" 3 1/2"

TYPE A1

ALUM FULL GLASS

MOTOR LOCATION

CANOPY FASCIA

LED INDICATOR

COLLAPSING MECHANISM

SIDE WALL BASE

TYPE R

ALUMINUM REVOLVING

DOOR - BALLSITIC

LEVEL 3

T1

• EXTERIOR

• ALUMN. OFFSET

/4

M

A X

T4

• EXTERIOR

• ALUMN. PANIC EXIT

/2

M

A X

/4

M

A X

/4

M

A X

/2

10 1/2"

JAMB MOUNT

ACTUATOR PLATE.

COORD W/ ELEC DWGS

/4

/2

N O

M

D O

O R

O

P E

N

IN

G

COORD DOOR PUSH

PLATE, LATCH AND

ELEC STRIKE

INSTALLATION

C .L

T

Y P

IC

A

L L

O C

K S

E T

/1

C .L

D

E A

D B

O L T

C .L

E

X

IT

D E

V

IC

E

/1

C .L

P

U L

L P

L A

T E

P

U S

H P

L A

T E

A R

M O

R P

L A

T E

K

IC

K P

L A

T E

E Q

E Q

/4

M A

X

M A

X

FINISH

FLOOR

SCHEDULED DOOR

JAMB BEYOND

DOUBLE ANGLE

STEEL LINTEL

HOLLOW METAL

FRAME

FULLY GROUT FRAME

LOOSE LINTEL NOTES:

1. LINTELS SHALL BEAR ON SOLID MASONRY OR ON

TWO CMU COURSES FULLY GROUTED, UON.

2. COORDINATE, FURNISH AND INSTALL ALL LOOSE

LINTELS REQUIRED FOR ALL OPENINGS IN

MASONRY, INCLUDING MECHANICAL AND

ELECTRICAL WORK, WHETHER SPECIFICALLY

MENTIONED ON DRAWINGS OR NOT.

3. ALL LINTELS AT EXTERIOR LOCATIONS OR

OTHERWISE SUBJECT TO WEATHER OR

CORROSIVE ATMOSPHERE SHALL BE GALVANIZED.

6" BEARING EACH END:

(2) L 2 1/2 x 2 1/2 x 1/4 MAXIMUM CLEAR SPAN: 4'-0"

SCHEDULED DOOR

FULLY GROUT FRAME

HOLLOW METAL FRAME

NKB

N. .______________________________________________________

ARCHITECTURE & ENGINEERING, PC..

K BHANDARI

RENOVATION

SHEET SIZE: 34 X 44

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs.

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. FIRM

SUB A/E

PRIME A/E

A/E CON. NO.

D R

A W

IN

G

P R

O J E

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R A

P H

IC

S C

A L

E R

E V

IS

IO

N N

O T

E S

C E

R T

IF

IC

A T

IO

N

S

MARK DATE DESCRIPTION

SHEET OF

NK BHANDARI ARCHITECTURE

C&S ENGINEERS

GS-07-P-16-UC-D-7008

K E

Y P

L A

N

SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.

DATE:

A

SUB A/E

CONSTR. CON. -

NYS EDUCATION LAW, SECTION 7209 AND 69.5(B)

PROHIBITS ANY PERSON TO ALTER THESE DRAWINGS

OTHER THAN A LICENSED ARCHITECT OR THE DESIGN

ENGINEER. INFORMATION ON THESE DRAWINGS FOR

GSA ONLY, AND CAN BE UTILIZED BY GSA AS THEY

DEEM NECESSARY.

COPYRIGHT 2022

N. K. BHANDARI, ARCHITECTURE & ENGINEERING, P.C.

1005 W. Fayette Street, Suite 500 Syracuse, NY 13204

Phone Fax www.nkbpc.com

315.428.1177 315.428.9822

499 Col. Eileen Collins Blvd Syracuse, NY 13212

Phone www.cscos.com

315.455.2000

U.S. General Services Administration

100 STATE STREET

ROCHESTER, NY 14614

B

C

D

3 4 51

C:\Users\pdd\Documents\R21_16320.xx.126 GSA Keating Lobby Security - Design_CENTRAL_pdudkowskiD8JHD.rvt

/1

/2

:5 :3

P

M

SCHEDULES AND DIAGRAMS

LOBBY SECURITY UPGRADES

PDD

BNV 3/11/2022

RWA A5010736

3/11/2022

31 60

FOR CONSTRUCTION

AE600

PETER SMITH

KENNETH B. KEATING

DOOR SCHEDULE

DOOR

NUMBER ROOM NAME

ROOM

NUMBER

DOOR FRAME

THRESHOLD

FIRE

RATING REMARKS

HARDWARE

SET

DOOR

NUMBERWIDTH HEIGHT THICKNESS LEAF SIZE TYPE

DOOR

MATERIAL FINISH FRAME TYPE

FRAME

MATERIAL FRAME FINISH

FRAME

DETAIL

1205A MAIN LOBBY 1205A 3' - 0" 7' - 0" 0' - 1 3/4" 36 B1 ALUM 710 ANON ABL ALUM 710 ANON BY MFR T4 0 1, 2, 9 7 1205A

1205B GUN LOCKER 1205B 3' - 0" 8' - 0" 0' - 1 3/4" 36 B1 ALUM 710 ANON ABA ALUM 710 ANON BY MFR - 0 8 1205B

1205C SECURITY STATION 1205C 3' - 0" 8' - 0" 0' - 1 3/4" 36 B1 ALUM 710 ANON ABA ALUM 710 ANON BY MFR - 0 1, 3, 11 9 1205C

1205D PUBLIC ENTRY

LOBBY

1205D 7' - 3" 8' - 11 13/16" 0' - 1 9/16" 40 R1 ALUM 710 ANON REVOLVING ALUM 710 ANON BY MFR - 0 1, 6 3 1205D

1205E EXIT VESTIBULE 1025E 3' - 0" 7' - 0" 0' - 1 3/4" 36 B1 ALUM 710 ANON A2 ALUM 710 ANON BY MFR T4 0 1, 5 2 1205E

1205E.1 PUBLIC ENTRY

LOBBY

1205D 3' - 0" 7' - 0" 0' - 1 3/4" 36 A1 ALUM 710 ANON ABL ALUM 710 ANON BY MFR - 0 1, 2, 7 4 1205E.1

1205F ENTRY VESTIBULE 1025F 3' - 0" 7' - 0" 0' - 1 3/4" 36 B1 ALUM 710 ANON A2 ALUM 710 ANON BY MFR T4 0 1, 4 1 1205F

1205F.1 PUBLIC ENTRY

LOBBY

1205D 3' - 0" 7' - 0" 0' - 1 3/4" 36 A1 ALUM 710 ANON ABL ALUM 710 ANON BY MFR - 0 1, 2, 7 4 1205F.1

1205G STAIRWELL

VESTIBULE

1205G 3' - 0" 7' - 0" 0' - 1 3/4" 36 B1 ALUM 710 ANON ABL ALUM 710 ANON BY MFR T4 0 1, 2, 8 5 1205G

1205H STORAGE 1205H 4' - 0" 7' - 0" 0' - 1 3/4" 48 F HM PNT H1 HM PNT BY MFR T4 60 MIN 1, 2, 8 6 1205H

1205O MAIN LOBBY 1205A 3' - 0" 7' - 0" 0' - 1 3/4" 36 B1 ALUM 710 ANON A1 ALUM 710 ANON BY MFR - 0 1, 11 9 1205O

DOOR HARDWARE SCHEDULE

QTY ITEM

BOD

MFR DESCRIPTION FINISH REMARKS

SET 1

1 HINGE CONTINUOUS GEARED PEMKO D x FM x 83 x CP x HD3 x TMS 710

1 EXIT DEVICE (PANIC) WITH TRIM (NIGHT LATCH) EL x RIM x

REX

VON DUPRIN RX-99-NL-06-B x TMS 626

1 CYLINDER MEDECO B SFIC Interchangable Core 626

1 DOOR OPERATOR STANLEY MAGIC SWING x SU100 SENSOR x 120V 689

1 PUSH BUTTON ACTUATOR STANLEY TOUCH PAD 689

1 ELECTRIC STRIKE HES 9600 x TMS 626

1 OVERHEAD STOP ROCKWOOD OH901S x TMS 626

1 CLOSER LCN 4010 REGULAR ARM x TMS 689

1 KICK PLATE ROCKWOOD K 1050 x 10" x 1.5" LDW x 4BE x CSK x SMS 626

1 THRESHOLD PEMKO 2005-T-A x LA 719

1 WEATHERSTRIP PEMKO 2891-PK x SMS 710

1 AUTOMATIC DOOR BOTTOM PEMKO 420-PKL-A x TMS 719

1 DRIP CAP PEMKO 346-D x SMS 710

1 DOOR CONTACT POSTION SWITCH INTERLOGIX 1076 BLACK

1 PROXIMITY READER TBD TBD x EWA TBD

SET 2

1 HINGE CONTINUOUS GEARED PEMKO D x FM x 83 x CP x HD3 x TMS 710

1 EXIT DEVICE (PANIC) WITH TRIM (NIGHT LATCH) RIM VON DUPRIN 99-NL-06-B x TMS 626

1 CYLINDER MEDECO B SFIC Interchangable Core 626

1 DOOR OPERATOR STANLEY MAGIC SWING x SU100 SENSOR x 120V 689

1 OVERHEAD STOP ROCKWOOD OH901S x TMS 626

1 CLOSER LCN 4010 REGULAR ARM x TMS 689

1 KICK PLATE ROCKWOOD K 1050 x 10" x 1.5" LDW x 4BE x CSK x SMS 626

1 THRESHOLD PEMKO 2005-T-A x LA 719

1 WEATHERSTRIP PEMKO 2891-PK x SMS 710

1 AUTOMATIC DOOR BOTTOM PEMKO 420-PKL-A x TMS 719

1 DRIP CAP PEMKO 346-D x SMS 710

1 DOOR CONTACT POSTION SWITCH INTERLOGIX 1076 BLACK

SET 3 REVOLVING DOOR

4 DURRESS SECURITY BOLTS TBD PER MANUFACTURER TBD

1 WEATHSTRIP TBD PER MANUFACTURER TBD

SET 4

1 HINGE CONTINUOUS GEARED PEMKO D x FM x 83 x CP x HD3 x TMS 710

1 EXIT DEVICE (PANIC) WITH TRIM (LEVER) RIM VON DUPRIN 99-L-06-B x TMS 626

1 CYLINDER MEDECO B SFIC Interchangable Core 626

1 DOOR OPERATOR STANLEY MAGIC SWING x SU100 SENSOR x 120V 689

1 DURESS SECURITY BOLTS TBD TBD 626

1 OVERHEAD STOP ROCKWOOD OH901S x TMS 626

1 CLOSER LCN 4010 REGULAR ARM x TMS 689

1 KICK PLATE ROCKWOOD K 1050 x 10" x 1.5" LDW x 4BE x CSK x SMS 626

1 DOOR CONTACT POSTION SWITCH INTERLOGIX 1076 BLACK

3 SILENCERS IVES SR64 GRAY

SET 5

1 HINGE CONTINUOUS GEARED PEMKO D x FM x 83 x CP x HD3 x TMS 710

1 EXIT DEVICE (PANIC) WITH TRIM (NIGHT LATCH) EL x RIM x

REX

VON DUPRIN RX-99-NL-06-B x TMS 626

1 CYLINDER MEDECO B SFIC Interchangable Core 626

1 ELECTRIC POWER TRANSFER VON DUPRIN EPT-2 x TMS 626

1 ELECTRIC STRIKE HES 9600 x TMS 626

1 OVERHEAD STOP ROCKWOOD OH901S x TMS 626

1 CLOSER LCN 4010 REGULAR ARM x TMS 689

1 KICK PLATE ROCKWOOD K 1050 x 10" x 1.5" LDW x 4BE x CSK x SMS 626

1 THRESHOLD PEMKO 2005-T-A x LA 719

1 WEATHERSTRIP PEMKO 2891-PK x SMS 710

1 AUTOMATIC DOOR BOTTOM PEMKO 420-PKL-A x TMS 719

1 DRIP CAP PEMKO 346-D x SMS 710

1 DOOR CONTACT POSTION SWITCH INTERLOGIX 1076 BLACK

1 PROXIMITY READER TBD TBD x EWA TBD

SET 6

1 HINGE CONTINUOUS GEARED PEMKO D x FM x 83 x CP x HD3 x TMS 710

1 LOCKSET MORTISE (STORAGE) x REX SCHLAGE L9090EL-06-B, FAIL SECURE x TMS 626

1 CYLINDER MEDECO B SFIC Interchangable Core 626

1 ELECTRIC POWER TRANSFER VON DUPRIN EPT-2 x TMS 626

1 ELECTRIC STRIKE HES 9600 x TMS 626

1 OVERHEAD STOP ROCKWOOD OH901S x TMS 626

1 CLOSER LCN 4010 REGULAR ARM x TMS 689

1 KICK PLATE ROCKWOOD K 1050 x 10" x 1.5" LDW x 4BE x CSK x SMS 626

1 THRESHOLD PEMKO 2005-T-A x LA 719

1 WEATHERSTRIP PEMKO 2891-PK x SMS 710

1 AUTOMATIC DOOR BOTTOM PEMKO 420-PKL-A x TMS 719

1 DRIP CAP PEMKO 346-D x SMS 710

1 DOOR CONTACT POSTION SWITCH INTERLOGIX 1076 BLACK

1 PROXIMITY READER TBD TBD x EWA TBD

SET 7

1 HINGE CONTINUOUS GEARED PEMKO D x FM x 83 x CP x HD3 x TMS 710

1 EXIT DEVICE (PANIC) WITH TRIM (EXIT ONLY) EL x RIM x

LOCAL ALARM

MCKINNEY T4A3386 x 4.5 x 4.5 x TMS 630

1 ELECTRIC POWER TRANSFER VON DUPRIN EPT-2 x TMS 626

1 OVERHEAD STOP ROCKWOOD OH901S x TMA 626

1 CLOSER LCN 4010 REGULAR ARM x TMS 689

1 KICK PLATE ROCKWOOD K 1050 x 10" x 1.5" LDW x 4BE x CSK x SMS 626

1 THRESHOLD PEMKO 2005-T-A x LA 719

1 WEATHERSTRIP PEMKO 2891-PK x SMS 710

1 AUTOMATIC DOOR BOTTOM PEMKO 420-PKL-A x TMS 719

1 DRIP CAP PEMKO 346-D x SMS 710

1 DOOR CONTACT POSTION SWITCH INTERLOGIX 1076 BLACK

SET 8 60 MIN

3 HINGES FULL MORTISE MCKINNEY T4A3386 x 4.5 x 4.5 x TMS 626

1 LOCKSET MORTISE (STORAGE) x REX SCHLAGE L9090EL-06-B, FAIL SECURE x TMS 626

1 CYLINDER MEDECO B SFIC Interchangable Core 626

1 ELECTRIC POWER TRANSFER VON DUPRIN EPT-2 x TMS 626

1 ELECTRIC STRIKE HES 9600 x TMS 626

1 WALL STOP ROCKWOOD 409 x EWA GRAY

1 CLOSER LCN 4010 REGULAR ARM x TMS 689

1 DOOR CONTACT POSTION SWITCH INTERLOGIX 1076 BLACK

3 SILENCERS IVES SR64 GRAY

SET 9

1 HINGE CONTINUOUS GEARED PEMKO D x FM x 83 x CP x HD3 x TMS 710

1 EXIT DEVICE (PANIC) WITH TRIM (NIGHT LATCH) EL x RIM x

REX

VON DUPRIN RX-99-NL-06-B x TMS 626

1 CYLINDER MEDECO B SFIC Interchangable Core 626

1 ELECTRIC POWER TRANSFER VON DUPRIN EPT-2 x TMS 626

1 ELECTRIC STRIKE HES 9600 x TMS 626

1 OVERHEAD STOP ROCKWOOD OH901S x TMS 626

1 CLOSER LCN 4010 REGULAR ARM x TMS 689

1 KICK PLATE ROCKWOOD K 1050 x 10" x 1.5" LDW x 4BE x CSK x SMS 626

1 DOOR CONTACT POSTION SWITCH INTERLOGIX 1076 BLACK

1 PROXIMITY READER TBD TBD TBD

3 SILENCERS IVES SR64 GRAY

SET 10

1 HINGE CONTINUOUS GEARED PEMKO D x FM x 83 x CP x HD3 x TMS 710

1 EXIT DEVICE (PANIC) WITH TRIM (LEVER) RIM VON DUPRIN 99-L-06-B x TMS 626

1 CYLINDER MEDECO B SFIC Interchangable Core 626

1 DOOR OPERATOR STANLEY MAGIC SWING x SU100 SENSOR x 120V 689

1 PUSH BUTTON ACTUATOR STANLEY TOUCH PAD 689

1 DURESS SECURITY BOLTS TBD TBD 626

1 OVERHEAD STOP ROCKWOOD OH901S x TMS 626

1 CLOSER LCN 4010 REGULAR ARM x TMS 689

1 KICK PLATE ROCKWOOD K 1050 x 10" x 1.5" LDW x 4BE x CSK x SMS 626

1 DOOR CONTACT POSTION SWITCH INTERLOGIX 1076 BLACK

3 SILENCERS IVES SR64 GRAY

1/4" = 1'-0"AE600

3 DOOR FRAME TYPES

1/4" = 1'-0"AE600

2 DOOR TYPES

6" = 1'-0"AE600

1 THRESHOLDS

DOOR SCHEDULE NOTES

1 DOOR GEOMETRY: ALL DOORS TO BE 1 ¾” THICK X 84” HIGH UON. PROVIDE DOORS OF MATERIAL, CONSTRUCTION, AND FINISH PER

THE DRAWINGS AND SPECIFICATIONS

2 UNDERCUT / CLEARANCES: ALL DOOR UNDERCUTS TO BE ¾” UON. ACTUAL CLEARANCE AT THRESHOLD OF FIRE RATED DOORS IS TO BE PROVIDED PER THE TESTED AND LISTED ASSEMBLY, ALLOWING FOR PROPER OPERATION AND PROPER ENGAGEMENT OF ALL

REQUIRED HARDWARE ON THE RATED OPENING.

3 DOOR AND FRAME DUTY: PROVIDE DOOR AND FRAMES OF THE APPROPRIATE DUTY AND CONSTRUCTION AS SHOWN ON THE

DRAWINGS AND AS SPECIFIED.

4 DOOR WIDTH CONVENTION: DOOR LEAF WIDTH IS INDICATED IN INCHES IN THE DOOR SCHEDULE. TWO NUMBERS SEPARATED BY A

FORWARD SLASH (/) INDICATES DOUBLE DOORS.

5 FRAMES: ALL FRAMES TO BE OF MATERIAL, CONSTRUCTION, AND FINISH PER THE DRAWINGS AND SPECIFICATIONS. PROVIDE FRAME ANCHOR TYPE TO SUIT WALL CONSTRUCTION AND ANCHOR QUANTITY PER HMMA 840-14. ALL FRAMES TO OVERLAP WALL FINISH

UON.

6 FRAME CONSTRUCTION: HM FRAMES ARE TO BE MITERED AND FULLY WELDED UON. KNOCK DOWN FRAMES WILL THE INDICATED ON

THE DRAWINGS AND IN THE SPECIFRICATIONS IF THEY ARE TO BE USED.

B LABEL = 1 ½ HOURS

C LABEL = ¾ HOUR

7 DOOR AND FRAME FIRE RATING: WHERE FIRE RATED DOORS ARE INDICATED, DOOR FRAME RATING SHALL EQUAL THE DOOR RATING.

BORROWED LIGHT FRAMES FOR WINDOWS INSTALLED IN FIRE RATED PARTITIONS TO BE RATED SAME AS DOOR FRAMES AND BE

COMPATIBLE WITH WALL TYPE.

8 FIRE DOOR ASSEMBLIES: FIRE DOOR ASSEMBLIES SHALL COMPLY WITH NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES. FIRE RATED OPENINGS SHALL BE TESTED AND OR LISTED BY ONE OF THE FOLLOWING THREE AGENCIES: 1) UNDERWRITERS LABORATORIES, 2) INTERTEK / WARNOCK HERSEY MARK, OR 3) FACTORY MUTUAL. FIRE RATING LABELS ARE TO BE

AS FOLLOWS:

A LABEL = 3 HOURS (180 MIN)

B LABEL = 1 ½ HOURS (90 MIN)

C LABEL = ¾ HOUR (45 MIN)

9 GLAZING: ALL VISION PANELS IN FIRE RATED DOORS AND FRAMES TO BE OF GLAZING TYPE AND THICKNESS AS SHOWN ON THE DRAWINGS AND IN THE SPECIFICATIONS. ALL VISION PANELS IN NON-RATED DOORS AND FRAMES TO BE SAFETY GLASS UON. ALL EXTERIOR DOOR LIGHTS, TRANSOMS, AND SIDELIGHTS TO BE 1” INSULATING TEMPERED GLASS UON.

10 HARDWARE REINFORCEMENT: DOORS AND FRAMES SHALL BE REINFORCED FOR INSTALLATION OF ALL HARDWARE. DRILLING AND TAPPING FOR ATTACHING OF SURAFCE MOUNTED HARDWARE TO BE PROVIDED FOR COMPLETE FUNCTIONAL DOOR OPENING.

11 DOOR POSITION: FINISHED DOOR OPENINGS SHALL BE NOMINAL 6” FROM FINISHED CORNER OF ROOM AT HINGE SIDE, EXCEPT WHERE DIMENSIONED OTHERWISE. ON THE “PULL” SIDE OF A DOOR OPENING, THE STRIKE SIDE SHALL BE NOMINAL 18” FROM A PERPENDICULAR WALL. ON THE “PUSH” SIDE OF A DOOR OPENING EQUIPPED WITH BOTH A CLOSER AND LATCH, THE STRIKE SIDE

SHALL BE NOMINAL 12” FROM A PERPENDICULAR WALL.

12 MASONRY OPENING LINTELS: ALL MASONRY OPENINGS TO RECEIVE LINTELS. REFER TO LINTEL SCHEDULE FOR MORE INFORMATION.

13 GROUTING OF FRAMES IN MASONRY: WHEN FRAMES ARE IN MASONRY CONSTRUCTION TO BE FILLED WITH GROUT AND ANTI-FREEZE AGENTS ARE PRESENT, THE INSIDES OF THE FRAMES SHALL BE TREATED BY THE GENERAL CONTRACTOR WITH A SUITABLE

BITUMINOUS UNDERCOATING MATERIAL AS SPECIFIED.

14 FRAME BOX-OUTS: PROVIDE BOX-OUTS (MORTAR BOXES, STRIKE BOXES, ACCESS CONTROL HARDWARE, ETC.) IN DOOR FRAMES

WHERE FRAMES ARE GROUTED OR IN MASONRY WALL.

15 JAMB AND HEAD STUDS: AT METAL STUD WALLS (GYPSUM BOARD WALLS), PROVIDE 20 GA METAL STUDS AT JAMBS AND HEADS OF

DOOR OPENINGS UON.

16 EXTERIOR DOORS AND FRAMES: ALL EXTERIOR HOLLOW METAL DOORS AND FRAMES SHALL BE PROVIDED UTILIZING

METALLIC-COATED STEEL (GALVANIZED) STEEL SHEETS AS SPECIFIED.

17 PRE-TREAMENT AND PRIME PAINT: ALL HOLLOW METAL DOORS AND FRAMES SHALL RECEIVE AN IRON PHOSPHATE PRE-TREATMENT

AND ONE COAT OF BAKED ON PRIME PAINT.

18 EXISTING OPENING COMPONENTS: WHERE AN EXISTING OPENING COMPONENT (DOOR, FRAME, HARDWARE) IS TO BE RE-USED, EACH COMPONENT SHALL BE INDICATED AS “EX” IN THE SCHEDULE, DENOTING “EXISTING”. ALL EXISTING COMPONENTS ARE TO BE INSPECTED IN THE FIELD, VERIFY 1) DIMENSIONAL CHARACTERESTICS, 2) MOUNTING HEIGHTS / GEOMETRIES, 3) MANUFACTURER / MODEL INFORMNATION, and 4) FIRE RATED LABEL OR LISTING INFORMATION AVAILABLE FOR EACH COMPONENT.

19 ACCESS CONTROL RACEWAYS: PROVIDE ALL RACEWAYS REQUIRED FOR THE COMPLETE INSTALLATION AND PROPER OPERATION OF ALL SCHEDULED ACCESS CONTROL HARDWARE. REFER TO DOOR AND HARDWARE SCHEDULES, ACCESS CONTROL DRAWINGS, AND

RELATED SPECIFICATIONS FOR MORE INFORMATION.

20 OPERATIONAL DESPCRIPTION: DOOR ACCESS CONTROL OPERATIONAL DESCRIPTION TO BE AS INDICATED IN THE DRAWINGS AND SPECIFICATIONS. CONFIRM OPERATIONAL DESCRIPTION / SEQUENCE THROUGH SUBMITTAL AND REVIEW PROCESS WITH ARCHITECT

/ OWNER.

21 STORAGE OF DOORS AND FRAMES: STORE DOORS AND FRAMES AT THE PROJECT UNDER COVER AS SPECIFIED. PLACE UNITS ON AT LEAST 4” WOOD SILLS OR ON FLOOR IN A MANNER THAT WILL PREVENT RUST AND DAMAGE. AVOID USE OF NON-VENTED PLASTIC OR CANVAS SHELTERS, WHICH CREATE A HUMIDITY CHAMBER. IF THE WRAPPER ON ANY COMPONENT BECOMES WET, REMOVE IMMEDIATELY, PROVIDE ¼” SPACE BETWEEN DOORS AND FRAMES TO PROMOTE CIRCULATION. ADDITIONAL STORAGE INFORMATION

PER ANSI A250.8 (SDI100) IS RECOMMENDED.

22 DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM.

23 FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS:

1.INTERIOR HINGED DOORS AND GATES: 5 POUNDS (22.2 N) MAXIMUM.

2.SLIDING OR FOLDING DOORS: 5 POUNDS (22.2 N) MAXIMUM.

THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE

DOOR OR GATE IN A CLOSED POSITION.

DOOR SCHEDULE REMARKS

KEY

NAME DOOR SCHEDULE REMARKS

1 ELECTRONIC SECURITY - REFER TO HARDWARE SETS AND SECURITY DRAWINGS.

2 BLAST RATED OPENING

3 BALLISTIC RATED OPENING

4 OPERATIONAL DESCRIPTION 1: INGRESS FREE ACCESS DURING BUSINESS HOURS (PUSH-BUTTON ACTUATOR WITH AUTOMATIC OPERATOR). INGRESS BY PROXIMITY READER AFTER BUSINESS HOURS. INGRESS MANUAL OVERRIDE WITH KEY. EGRESS ALWAYS FREE WITH EXIT DEVICE. FAIL SECURE. OPERATOR AND ALL HARDWARE TO BE INTERCONNECTED / CONTROLLED FOR PROPER OPERATION

OF ALL DOOR FUNCTIONS.

5 OPERATIONAL DESCRIPTION 2: INGRESS NOT PERMITTED DURING BUSINESS HOURS OR AFTER BUSINESS HOURS. INGRESS MANUAL OVERRIDE WITH KEY. EGRESS ALWAYS FREE WITH INFRARED SENSOR WITH AUTOMATIC OPERATOR OR EXIT DEVICE. FAIL SECURE.

OPERATOR AND ALL HARDWARE TO BE INTERCONNECTED / CONTROLLED FOR PROPER OPERATION OF ALL DOOR FUNCTIONS.

6 OPERATIONAL DESCRIPTION 3: INGRESS & EGRESS FREE DURING BUSINESS HOURS. LOCKED AFTER BUSINESS HOURS. DURESS

CONDITION: DOOR SECURED VIA DURESS BUTTON AT SECURITY STATION. FAIL SECURE.

7 OPERATIONAL DESCRIPTION 4: INGRESS & EGRESS FREE DURING BUSINESS HOURS OR AFTER BUSINESS HOURS VIA PUSH-BUTTON ACTUATOR OR INFRARED SENSOR WITH AUTOMATIC OPERATOR. DURESS CONDITION: DOOR SECURED VIA DURESS BUTTON AT SECURITY STATION. FAIL SAFE. OPERATOR AND ALL HARDWARE TO BE INTERCONNECTED / CONTROLLED FOR PROPER OPERATION OF

ALL DOOR FUNCTIONS.

8 OPERATIONAL DESCRIPTION 5: INGRESS BY PROXIMITY READER DURING OR AFTER BUSINESS HOURS. INGRESS MANUAL OVERRIDE

WITH KEY. EGRESS ALWAYS FREE. FAIL SECURE.

9 OPERATIONAL DESCRIPTION 6: INGRESS NOT PERMITTED AT ANY TIME. EGRESS DURING EMERGENCY CONDITION ONLY. EGRESS AT

ANY TIME WILL SOUND LOCAL ALARM. FAIL SECURE.

10 OPERATIONAL DESCRIPTION 7: INGRESS PERMITTED VIA PUSH BUTTON AT SECURITY STATION. INGRESS MANUAL OVERRIDE WITH KEY.

EGRESS ALWAYS FREE. FAIL SECURE.

11 OPERATIONAL DESCRIPTION 8: INGRESS PERMITTED VIA PROXIMITY READER. INGRESS MANUAL OVERRIDE WITH KEY. EGRESS ALWAYS

FREE. FAIL SECURE.

3" = 1'-0"AE400 AE600

5 CURTAIN WALL DOOR JAMB DETAILS

0 2' 4' 8'

0 2' 4' 8'

0 6" 1'3"

1/2" = 1'-0"AE600

4 TYPICAL DOOR HARDWARE HEIGHTS

0 1' 2'

2 1/18/23 ADDENDUM NO. 2

1 1/2" = 1'-0"AE600

6 DOOR HEAD DETAIL

1 1/2" = 1'-0"AE600

7 DOOR JAMB DETAIL

0 1' 2'0 1' 2'

DOOR SCHEDULE - TEMPORARY

DOOR

NUMBER ROOM NAME

ROOM

NUMBER

DOOR FRAME

THRESHOLD

FIRE

RATING REMARKS

HARDWARE

SET

DOOR

NUMBERWIDTH HEIGHT THICKNESS LEAF SIZE TYPE

DOOR

MATERIAL FINISH FRAME TYPE

FRAME

MATERIAL FRAME FINISH

FRAME

DETAIL

001 STORAGE 001 EXIST. 7' - 0" 0' - 1 3/4" EXIST. EXIST. EXIST. EXIST. H2 HM PNT 6&7/AE600 T1 EXIST. - EXIST. 001

002 VESTIBULE 002 EXIST. 7' - 0" 0' - 1 3/4" EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. NA EXIST. EXIST. - EXIST. 002

Sheets
AE600 - SCHEDULES AND DIAGRAMS
AE601 - INTERIOR FINISH PLAN AND SCHEDULES
G-110 - PHASING PLAN SHEETS

File details come from the government source that posted it. Updated .