Facilities | Environmental | Geotechnical | Materials I
City of Olathe Public Improvements
Asbestos Survey
Townsquare Shopping Center - Building 4
102-116 South Clairborne Road
Olathe, Kansas 66062
June 27, 2025 | Terracon Project Number: 02237230
Prepared for:
City of Olathe Kansas
100 East Santa Fe Street
Olathe, KS 66061
15620 W 113th Street
Lenexa, KS 66219
P (913) 492-7777
F (913) 492-7443
Terracon.com
Facilities | Environmental | Geotechnical | Materials i
June 27, 2025
City of Olathe, Kansas
100 East Santa Fe Street
Olathe, KS 66061
Attn: Ms. Therese Vink
P: (913) 971-9032
E: tmersmann@olatheks.org
Re: City of Olathe Public Improvements Asbestos Survey
Townsquare Shopping Center - Building 4
102-116 South Clairborne Road
Olathe, Kansas 66062
Terracon Project No: 02237230
Dear Ms. Vink:
Terracon Consultants, Inc. (Terracon) is pleased to provide the City of Olathe, Kansas, with this report regarding an asbestos survey conducted at the above-referenced location in Olathe, Kansas.
Asbestos
Asbestos was identified at a concentration greater than 1% in samples collected from the following materials:
Material Description Material Location
NESHAP
Category
Estimated
Quantity
Black/Yellow Mastic associated with 12" x 12" Tan Ceramic Floor
Tile with Grout and Mortar
Unit 104 - NE Restroom Category I
Nonfriable 31 Square Feet
Sheet Flooring with Paper Backing and Mastic
Unit 116A - South and SE- Central Rooms
Category I Nonfriable
675 Square Feet
Black Wall Mastic Units 106 & 108 - South
Wall, near Door Category I Nonfriable
6 Square Feet
Sealant Roof - West Area, on HVAC Category I Nonfriable
8 Linear Feet
Notes: NESHAP – National Emission Standards for Hazardous Air Pollutants
City of Olathe Public Improvements Asbestos Survey
Townsquare Shopping Center - Building 4 | Olathe, Kansas
June 27, 2025 | Terracon Project No. 02237230
Facilities | Environmental | Geotechnical | Materials ii
Asbestos was identified at a concentration of 1% or less in samples collected from the following materials:
Material Description Material Location
Joint Compound associated with Drywall Wallboard
System Throughout Subject Building
Grey Mortar + Inseparable Mastic associated with 12" x 12" Light Tan Ceramic Floor Tile with Grout and Mortar Unit 116A - NW Restroom
Please refer to Section 3.0 of the attached report for a detailed description of the asbestos survey, sampling activities, and findings.
Terracon appreciates the opportunity to provide this service to the City of Olathe, Kansas. If you have any questions regarding this report, please contact our office at
913-492-7777.
Sincerely, Terracon
Ryan Slanczka Clark Grisell
Senior Staff Scientist Environmental Group Manager
Building Environmental Sciences
Ryan Slanczka Clark Grisell
Facilities | Environmental | Geotechnical | Materials iii
Table Of Contents
1.0 Introduction 1
1.1 Reliance 1
2.0 Building Description 1
3.0 Asbestos-Containing Materials Survey 1
3.1 Visual Assessment 2
3.2 Physical Assessment 2
3.3 Sample Collection 2
3.4 Sample Analysis 2
3.5 Regulatory Overview 3
3.6 Findings 3
4.0 General Comments 5
Appendices
Appendix A Asbestos-Containing Materials By Homogeneous Area
Appendix B Asbestos Survey Sample Location Summary
Appendix C Asbestos Laboratory Analytical Results
Appendix D Certifications
Facilities | Environmental | Geotechnical | Materials 1
1.0 Introduction
Terracon Consultants, Inc. (Terracon) conducted an asbestos-containing material survey of the Townsquare Shopping Center - Building 4 located at 102-116 South Clairborne
Road in Olathe, Kansas, on May 9, 2025. Building areas were visually assessed for suspect asbestos-containing materials (ACM). A reasonable effort was made to inspect accessible areas. Additional suspect materials could be present in walls, voids, or other concealed areas.
1.1 Reliance
This report is for the exclusive use of the City of Olathe, Kansas, for the project being discussed. Reliance by any other party on this report is prohibited without the written authorization of Terracon and the City of Olathe, Kansas.
2.0 Building Description
The subject building is an approximately 12,428-square-foot, single-story community shopping center (with exterior metal canopy), reportedly constructed in 1975. Interior flooring finishes include faux-wood planks, ceramic tiles, sheet vinyl, carpeting, and vinyl tiles over concrete. Interior walls throughout the building are drywall/joint compound wallboard, with acoustic texture, wallpaper, and ceramic tile finishes in various areas. Perimeter walls throughout the building are concrete block and concrete block with concrete wall texture. The primary, observable ceiling system is a drop, grid ceiling with lay-in acoustic tiles below a metal deck. The building’s exterior has concrete block and fluted-block siding. The roof consists of a single-ply synthetic rubber membrane system.
3.0 Asbestos-Containing Materials Survey
The survey was conducted by Mr. Ryan Slanczka and Mr. Blake Harris, State of Kansas-accredited asbestos inspectors. Copies of the asbestos inspectors’ accreditations are attached as Appendix D. The survey was conducted in general accordance with the sample collection protocols established in the United States Environmental Protection
Agency (USEPA) 40 Code of Federal Regulations (CFR) Part 763 Subpart E 763.86, the
Asbestos Hazard Emergency Response Act (AHERA). A summary of survey activities is provided below.
Facilities | Environmental | Geotechnical | Materials 2
3.1 Visual Assessment
Survey activities were initiated with visual observation of the interior and exterior of the building to identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of a building material that appears similar throughout in terms of color and texture, with consideration given to the date of application. The assessment was conducted in visually accessible areas of the building scheduled for renovation.
3.2 Physical Assessment
A physical assessment of each HA of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material that can be crumbled, pulverized, or reduced to powder by hand pressure when dry.
Friability was assessed by physically touching suspect materials.
3.3 Sample Collection
Based on the results of the visual observation, bulk samples of suspect ACM samples were collected in general accordance with USEPA AHERA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each homogeneous area. Bulk samples were collected using wet methods, as applicable, to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
Rubber, wood products, plastic products, glass, and steel are not considered suspect
ACM and were, therefore, not sampled. The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content. Terracon collected 161 bulk samples from 48 homogeneous areas of suspect ACM.
3.4 Sample Analysis
Bulk samples were submitted under chain of custody to Eurofins International Asbestos
Testing Laboratories (Eurofins) of Mount Laurel, New Jersey, for analysis by PLM with dispersion staining techniques per USEPA Method 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. Eurofins is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), Accreditation No. 101165.
Facilities | Environmental | Geotechnical | Materials 3
3.5 Regulatory Overview
The asbestos National Emission Standards for Hazardous Air Pollutants (NESHAP) regulation (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
The asbestos NESHAP regulation classifies ACM as regulated asbestos-containing materials (RACM), Category I non-friable ACM, or Category II non-friable ACM. RACM includes all friable ACM; Category I non-friable ACM that has become friable or will be or has been subjected to sanding, grinding, cutting, or abrading; and Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder in the course of renovation or demolition activity. Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering mastics, and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. Category II non-friable ACM generally includes but is not limited to cementitious material such as cement pipes, cement siding, cement panels, glazing, mortar, and grouts.
The Kansas Department of Health and Environment’s (KDHE) Asbestos Control Section within the Bureau of Air enforces the Asbestos NESHAP as adopted by reference at
Kansas Administrative Regulations (K.A.R.) 28-19-735. The owner or operator must provide KDHE with written notification at least 10 working days prior to the commencement of asbestos abatement activities that will disturb RACM in amounts greater than or equal to 10 square feet or 25 linear feet.
The United States Occupational Safety and Health Administration (USOSHA) asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard classifies construction and maintenance activities that could disturb ACM and specifies work practices and precautions that employers must follow when engaging in each class of regulated work. The standard also specifies requirements for handling materials containing asbestos in concentrations less than or equal to one percent.
3.6 Findings
Asbestos was identified at a concentration greater than 1% in samples collected from the following materials:
Facilities | Environmental | Geotechnical | Materials 4
Material Description Material Location
NESHAP
Category
Estimated
Quantity
Black/Yellow Mastic associated with 12" x 12" Tan Ceramic Floor
Tile with Grout and Mortar Unit 104 - NE Restroom
Category I Nonfriable
31 Square Feet
Sheet Flooring with Paper Backing and Mastic
Unit 116A - South and SE- Central Rooms
Category I Nonfriable
675 Square Feet
Black Wall Mastic Units 106 & 108 - South
Wall, near Door
Category I
Nonfriable 6 Square Feet
Sealant Roof - West Area, on HVAC Category I Nonfriable
8 Linear Feet
Notes: NESHAP – National Emission Standards for Hazardous Air Pollutants
The above-listed Category I non-friable ACM that is damaged or could be damaged to the extent that it could be crumbled, pulverized, or reduced to powder when dry, making it friable, must be removed prior to any activities (renovation and/or demolition) that may disturb this material in accordance with applicable federal, state, and local regulations. Terracon recommends that all ACM be removed by an abatement contractor prior to any demolition or renovation work that may disturb it.
Asbestos was identified at a concentration of 1% or less in samples collected from the following materials:
Material Description Material Location
Joint Compound associated with Drywall Wallboard System
Throughout Subject Building
Grey Mortar + Inseparable Mastic associated with 12" x 12" Light Tan Ceramic Floor Tile with Grout and Mortar Unit 116A - NW Restroom
Materials containing 1% or less asbestos are not regulated by NESHAP or AHERA;
however, the USOSHA personal exposure limits (0.1 f/cc of air as an eight-hour time-weighted average or 1.0 f/cc of air over 30 minutes) for asbestos apply when materials containing 1% asbestos or less are disturbed during renovations or demolitions. A listing of materials that contain 1% asbestos or less is provided above to enable the renovation/demolition contractor to make appropriate decisions concerning compliance issues with applicable USOSHA regulations.
Joint Compound and/or tape that is applied to a wallboard system becomes an integral part of that wallboard system. A composite analysis of the wall system (percent of asbestos in the joint compound, tape, and wallboard composite) should be conducted where a demolition or renovation is to be performed and when allowed by regulations
(not allowed in some states). This is in addition to analysis by layers. State and local agencies should be consulted for additional regulatory requirements.
Facilities | Environmental | Geotechnical | Materials 5
A summary of identified asbestos-containing materials by homogeneous area is included in Appendix A. A summary of sample locations is included in Appendix B. Laboratory analytical reports are included in Appendix C.
4.0 General Comments
Terracon did not perform sampling that required demolition or destructive activities such as dismantling of equipment or removal of protective coverings. Reasonable efforts to access suspect materials within known areas of restricted access (e.g., crawl spaces) were made; however, confined spaces or areas that may pose a health or safety risk to
Terracon personnel were not sampled. Sampling did not include suspect materials that could not be safely reached with available ladders or manlifts. Terracon did not sample suspect materials that may be present in movable equipment such as freezers, kitchen equipment, and hoods. Terracon typically investigates for flooring beneath carpeting by lifting small corner sections of carpet. If tiles or sheet vinyl were seen, they have been identified in the report. If tiles or sheet vinyl were not seen at corners under the carpet, it does not imply that there is none beneath the carpeted floor. Terracon did not conduct a destructive investigation of the doors in the building to determine if the doors were insulated for fire-rating purposes.
This survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during Terracon’s survey of the building. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by the City of Olathe, Kansas, and is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in the preparation of this report. No warranty, express or implied, is made.
Appendix A
Asbestos-Containing Materials By Homogeneous Area
Appendix A-1
Identified Asbestos-Containing Materials By Homogeneous Area (HA)
102-116 South Clairborne Road, Olathe, Kansas
Terracon Project No. 02237230
HA Material Description Material Location % and Type
Asbestos*
NESHAP
Classification Condition
Estimated
Quantity**
Black/Yellow Mastic associated with 12" x 12"
Tan Ceramic Floor Tile with Grout and Mortar
Unit 104 - NE Restroom
Tan Ceramic Tile - None Detected
White Mortar - None Detected Black/Yellow Mastic - 2%
Chrysotile Off-White/Beige Grout - None
Detected
Category I Nonfriable
Good
Square Feet
27 Sheet Flooring with Paper Backing and Mastic
Unit 116A - South and SE- Central Rooms
Dark Red Sheet Flooring - 15% Chrysotile
Tan Mastic (Adhered to vinyl, not fibrous backing) - None
Detected Off-White Cementitious
Material - None Detected
Category I Nonfriable
Good
Square Feet
34 Black Wall Mastic Units 106 & 108 - South
Wall, near Door Black Mastic - 5% Chrysotile
Category I Nonfriable
Good
Square Feet
46 Sealant Roof - West Area, on HVAC Black/Grey Sealant - 15%
Chrysotile Category I Nonfriable
Good
Linear Feet
*% & Type Asbestos – this column contains both the analytical result of the sample with the highest concentration of asbestos detected in the samples that make up the HA, and the types of asbestos identified.
**Estimated quantities – quantities based on a cursory field evaluation, and actual quantities may vary significantly, especially if asbestos-containing materials are present in hidden and/or inaccessible areas not evaluated as part of this survey. This is not a bidding document; contractors are responsible for determining their own opinion of quantities.
Appendix A-2
Materials Containing Asbestos at a Concentration of 1% or Less By HA
HA Material Description Material Location % and Type
Asbestos* Condition
Joint Compound associated with Drywall
Wallboard System Throughout Subject Building
White Drywall with Brown Paper - None Detected White Joint Compound - <1% Chrysotile
White Tape - None Detected Tan Drywall with Brown Paper - None Detected
Damaged (Fair)
Grey Mortar + Inseparable Mastic associated with 12" x 12" Light Tan Ceramic Floor Tile with Grout and Mortar
Unit 116A - NW Restroom Tan/White Ceramic Tile - None Detected
Grey Mortar + Inseparable Mastic - <1% Chrysotile Off-White/Beige Grout - None Detected
Good
*% & Type Asbestos – this column contains both the analytical result of the sample with the highest concentration of asbestos detected in the samples that make up the HA, and the types of asbestos identified.
<1% - Materials containing less than 1% asbestos are not regulated by NESHAP or AHERA; however, the USOSHA personal exposure limits (0.1 f/cc of air as an eight-hour time-weighted average or 1.0 f/cc of air over 30 minutes) for asbestos apply when materials containing 1% asbestos or less are disturbed during renovation or demolition. A listing of materials that contain 1% asbestos or less is provided above to enable the renovation/demolition contractor to make appropriate decisions concerning compliance issues with applicable USOSHA regulations.
Appendix B
Asbestos Survey Sample Location Summary
Appendix B
Asbestos Survey Sample Location Summary
HA
No.
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
Drywall with Joint
Compound
01-WB5-01 Unit 114 - East Wall, Center
White Drywall with Brown Paper None Detected
White Joint Compound <1% Chrysotile
White Tape None Detected
01-WB5-02 Unit 114 - SW Office, West Wall
White Drywall with Brown Paper None Detected
White Joint Compound <1% Chrysotile
White Tape None Detected
01-WB5-03
Unit 112 - NE Area, West Wall, near NW
Room Door
White Drywall with Brown Paper None Detected
White Joint Compound None Detected
01-WB5-04 Unit 116A - NW Office, North Wall
White Drywall with Brown Paper None Detected
White Joint Compound None Detected
01-WB5-05
Unit 116B - South Room, West Wall, South
Area
White Drywall with Brown Paper None Detected
White Joint Compound None Detected
Tan Drywall with Brown Paper None Detected
01-WB5-06
Unit 108 - North Hallway, West Wall, near
North Door
White Drywall with Brown Paper None Detected
White Joint Compound None Detected
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
Drywall with Joint
Compound
01-WB5-07 Unit 102 - South Wall, Central Area
White Drywall with Brown Paper None Detected
White Joint Compound <1% Chrysotile
01-WB5-08 Unit 104 - SW Room, North Interior Wall
White Drywall with Brown Paper None Detected
White Joint Compound None Detected
2 Orange-Peel Wall Texture
02-PL1-09 Unit 112 - North Hallway, South Wall White Texture
None Detected
02-PL1-10 Unit 112 - NW Restroom, West Wall White Texture
02-PL1-11 Unit 112 - NW Area, North Wall White Texture
02-PL1-12 Unit 112 - West Wall, Central Area White Texture
02-PL1-13 Unit 112 - East Wall, Central Area White Texture
3 Orange-Peel Wall Texture
03-PL1-14 Unit 102 - East Wall White Texture
None Detected
03-PL1-15 Unit 102 - NE Room, West Wall White Texture
03-PL1-16 Unit 102 - SE Room, East Wall White Texture
03-PL1-17 Unit 102 - West Area, South Wall White Texture
03-PL1-18 Unit 102 - West Area, North Wall White Texture
4 Knockdown Wall Texture
04-PL1-19 Unit 104 - South Area, North Wall White Texture
None Detected
04-PL1-20 Unit 104 - West Area, South Wall White Texture
04-PL1-21 Unit 104 - North Hallway, North Wall White Texture
04-PL1-22 Unit 104 - NE Restroom, South Wall White Texture
04-PL1-23 Unit 104 - East Area, East Wall White Texture
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
Thick Knockdown Wall
Texture
05-PL1-24 Unit 116A - NW Restroom, North Wall White Texture
None Detected
05-PL1-25 Unit 116A - NE-Central Room, East Wall White Texture
05-PL1-26
Unit 116A - South Room, East Wall, Central
Area White Texture
05-PL1-27
Unit 116A - South Room, West Wall, Central
Area White Texture
05-PL1-28 Unit 116A - SW Office, North Wall White Texture
6 Wallpaper
06-SG5-29
Unit 108 - North Hallway, North Closet, North
Wall Grey Wallpaper
None Detected 06-SG5-30 Unit 108 - North Hallway, North Closet, East
Wall Grey Wallpaper
06-SG5-31
Unit 108 - North Hallway, North Closet, West
Wall Grey Wallpaper
7 Wallpaper
07-SG5-32 Unit 106 - South Area, West Wall Grey Wallpaper None Detected
07-SG5-33 Unit 106 - South Area, West Wall Grey Wallpaper None Detected
07-SG5-34 Unit 106 - South Area, West Wall
Grey Wallpaper None Detected
White Joint Compound* <1% Chrysotile
White Tape None Detected
8 Concrete Wall Texture
08-SC5-35 Unit 114 - NW Office, North Wall White Texture
None Detected
08-SC5-36 Unit 112 - North Wall White Texture
08-SC5-37 Unit 116A - NE Room, North Wall White Texture
08-SC5-38 Unit 110 - North Wall, Central Area White Texture
08-SC5-39 Unit 102 - NE Closet, North Wall White Texture
08-SC5-40 Unit 108 - Exterior, North, near Door White Texture with Brown Paint
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
8 Concrete Wall Texture 08-SC5-41 Unit 116B - Exterior, East, near SE Corner White Texture with Brown Paint None Detected
2' x 4' Ceiling Tile with
Pinholes and Divots
09-CT4-42 Unit 114 - East-Central Area White Ceiling Tile
None Detected 09-CT4-43 Unit 112 - West-Central Area White Ceiling Tile
09-CT4-44 Unit 116B - South Room, Central Area White Ceiling Tile
2' x 4' Ceiling Tile with
Pinholes and Fissures
10-CT4-45 Unit 114 - NW-Central Room, Central Area White Ceiling Tile
None Detected 10-CT4-46 Unit 112 - West-Central Area White Ceiling Tile
10-CT4-47 Unit 106 - South Room, North-Central Area White Ceiling Tile
2' x 4' Fiberglass Ceiling
Tile
11-CT4-48 Unit 114 - NW Room, Central Area White Ceiling Tile
None Detected 11-CT4-49 Unit 112 - West-Central Area White Ceiling Tile
11-CT4-50 Unit 110 - NE Restroom White Ceiling Tile
2' x 4' Ceiling Tile with
Pinholes and Fissures
12-CT4-51 Unit 112 - NE Area White Ceiling Tile
None Detected 12-CT4-52 Unit 112 - NW Area White Ceiling Tile
12-CT4-53 Unit 112 - NW Area White Ceiling Tile
4" Cove Base with Tan
Mastic
13-FC3-54 Unit 114 - East Wall, Center
Black Cove Base
None Detected
Tan Mastic
White Joint Compound
13-FC3-55 Unit 112 - NW Area, West Wall
Tan Cove Base
Cream Cove Base Mastic
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
4" Cove Base with Tan
Mastic 13-FC3-56 Unit 108 - Salesfloor, North Wall
Blue-Green Cove Base
None Detected
Cream Cove Base Mastic
4" Cove Base with Tan
Mastic
14-FC3-57 Unit 104 - West Wall, South of Door
Brown Cove Base
None Detected
Yellow Cove Base Mastic
Brown Cove Base Mastic
14-FC3-58 Unit 104 - South Wall, near Door
Cream Cove Base
Cream Cove Base Mastic
Brown Cove Base Mastic
14-FC3-59 Unit 104 - South Wall, near SE Corner
Brown Cove Base
Yellow Cove Base Mastic
Brown Cove Base Mastic
6" x 6" White Ceramic Wall
Tile with Grout and Mastic
15-MA5-60 Unit 102 - SE Area, North Wall
White Ceramic Tile
None Detected
White Grout
Tan Mastic
15-MA5-61 Unit 102 - SE Area, South Wall
White Ceramic Tile
White Grout
Tan Mastic
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
6" x 6" White Ceramic Wall
Tile with Grout and Mastic 15-MA5-62 Unit 102 - SE Restroom, East Wall
White Ceramic Tile
None Detected White Grout
Tan Mastic
4" x 4" Offwhite Ceramic
Wall Tile with Grout and
Mastic
16-MA5-63 Unit 106 - North Corridor, North Wall
Off-White Ceramic Tile
None Detected
White Grout
Tan Mastic
16-MA5-64 Unit 106 - North Corridor, North Wall
Off-White Ceramic Tile
White Grout
Tan Mastic
16-MA5-65 Unit 106 - North Corridor, East Wall
Off-White Ceramic Tile
White Grout
Tan Mastic
18" x 18" Tan Ceramic
Floor Tile with Grout and
Mortar
17-MA5-66 Unit 114 - NE Area
Tan Ceramic Tile
None Detected
Off-White Grout
Dark Grey Mortar
17-MA5-67 Unit 114 - NW Room, SE Area
Tan Ceramic Tile
Off-White Grout
Dark Grey Mortar
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
18" x 18" Tan Ceramic
Floor Tile with Grout and
Mortar
17-MA5-68 Unit 114 - SW Area
Tan Ceramic Tile
None Detected Off-White Grout
Dark Grey Mortar
12" x 12" Tan Ceramic
Floor Tile with Grout and
Mortar
18-MA5-69 Unit 114 - North Room
Tan Ceramic Tile
None Detected
Off-White Grout
Dark Grey Mortar
18-MA5-70 Unit 116A - NE Room, Central Area
Tan Ceramic Tile
Off-White Grout
Dark Grey Mortar
18-MA5-71 Unit 116A - NE Room, Central Area
Tan Ceramic Tile
Off-White Grout
Dark Grey Mortar
12" x 12" Tan Ceramic
Floor Tile with Grout and Mortar
19-MA5-72 Unit 104 - NE Restroom, near South Door
Tan Ceramic Tile None Detected
White Mortar None Detected
Black/Yellow Mastic 2% Chrysotile
Off-White/Beige Grout None Detected
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
12" x 12" Tan Ceramic
Floor Tile with Grout and Mortar
19-MA5-73 Unit 104 - NE Restroom, near West Door
Tan Ceramic Tile None Detected
White Mortar None Detected
Black/Yellow Mastic 2% Chrysotile
Off-White/Beige Grout None Detected
19-MA5-74 Unit 104 - NE Restroom, near West Door
Tan Ceramic Tile None Detected
White Mortar None Detected
Black/Yellow Mastic 2% Chrysotile
Off-White/Beige Grout None Detected
12" x 12" Light Tan
Ceramic Floor Tile with
Grout and Mortar
20-MA5-75 Unit 116A - NW Restroom, near Door
Tan/White Ceramic Tile None Detected
Grey Mortar + Inseparable
Mastic <1% Chrysotile
Off-White/Beige Grout None Detected
20-MA5-76 Unit 116A - NW Restroom, near Door
Tan/White Ceramic Tile None Detected
Grey Mortar + Inseparable
Mastic <1% Chrysotile
Off-White/Beige Grout None Detected
20-MA5-77 Unit 116A - NW Restroom, near Door
Tan/White Ceramic Tile None Detected
Grey Mortar + Inseparable
Mastic <1% Chrysotile
Off-White/Beige Grout None Detected
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
12" x 12" Red Ceramic
Floor Tile with Grout and
Mortar
21-MA5-78 Unit 116B - North Restroom, near Door
Red Ceramic Tile
None Detected
Brown Grout
Light Grey Mortar
21-MA5-79 Unit 116B - South Room, NW Area
Red Ceramic Tile
Brown Grout
Light Grey Mortar
21-MA5-80 Unit 116B - South Room, SE Area
Red Ceramic Tile
Brown Grout
Light Grey Mortar
12" x 12" Tan Floor Tile with Mastic
22-FT2-81 Unit 112 - NW Restroom
Tan Floor Tile
None Detected
Tan Mastic
White Fibrous Material
(Possible Sheet Floor Backing)
22-FT2-82 Unit 112 - North Hallway
Tan Floor Tile
Tan Mastic
22-FT2-83 Unit 112 - North Hallway
Tan Floor Tile
Tan Mastic
White Fibrous Material
(Possible Sheet Floor Backing)
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
12" x 12" Black Floor Tile with Mastic
23-FT2-84 Unit 112 - NW Room, SW Area
Black Floor Tile
None Detected
Tan Mastic
Transparent Mastic
23-FT2-85 Unit 112 - North-Central Area
Black Floor Tile
Tan Mastic
Transparent Mastic
23-FT2-86 Unit 112 - NW Area
Black Floor Tile
Tan Mastic
Transparent Mastic
12" x 12" Offwhite Floor
Tile with Tan Mastic
24-FT2-87 Unit 102 - NE Closet
Off-White Floor Tile
None Detected
Tan Mastic
24-FT2-88 Unit 102 - NE Closet
Off-White Floor Tile
Tan Mastic
24-FT2-89 Unit 102 - NE Closet
Off-White Floor Tile
Tan Mastic
12" x 12" Blue Floor Tile with Tan Mastic
25-FT2-90 Unit 102 - NE Closet
Blue Floor Tile
None Detected
Tan Mastic
25-FT2-91 Unit 102 - NE Closet
Blue Floor Tile
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
12" x 12" Blue Floor Tile with Tan Mastic 25-FT2-92 Unit 102 - NE Closet
Blue Floor Tile
None Detected
Tan Mastic
12" x 12" Grey Floor Tile with Tan Mastic
26-FT2-93 Unit 106 - South Room, near South Door
Light Grey Floor Tile
None Detected
Yellow Mastic
26-FT2-94 Unit 106 - South Room, near South Door
Light Grey Floor Tile
Yellow Mastic
26-FT2-95 Unit 106 - South Room, near South Door
Light Grey Floor Tile
Yellow Mastic
Sheet Flooring with
Paper Backing and
Mastic
27-FC1-96
Unit 116A - South Room, East-Central
Area
Dark Red Sheet Flooring 15% Chrysotile
Tan Mastic (Adhered to vinyl, not fibrous backing) None Detected
27-FC1-97
Unit 116A - South Room, East-Central
Area
Dark Red Sheet Flooring 15% Chrysotile
Tan Mastic (Adhered to vinyl, not fibrous backing) None Detected
27-FC1-98
Unit 116A - SE-Central Room, near West
Doorway
Dark Red Sheet Flooring 15% Chrysotile
Tan Mastic (Adhered to vinyl, not fibrous backing) None Detected
Off-White Cementitious
Material None Detected
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
Square-Pattern Sheet
Flooring
28-FC1-99 Unit 106 - South Room, near South Door
Yellow Floor Tile
None Detected
Transparent Mastic (Top)
Yellow Mastic + Inseparable Tan
Mastic
28-FC1-100 Unit 106 - South Room, near South Door
Yellow Floor Tile
Transparent Mastic (Top)
Yellow Mastic + Inseparable Tan
Mastic
28-FC1-101 Unit 106 - South Room, near South Door
Yellow Floor Tile
Transparent Mastic (Top)
Yellow Mastic + Inseparable Tan
Mastic
Faux-Wood Plank Flooring with Tan Mastic
29-FT5-102 Unit 114 - South-Central Area
Brown Flooring
None Detected
Tan Mastic
29-FT5-103 Unit 114 - North-Central Area
Brown Flooring
Tan Mastic
29-FT5-104 Unit 114 - West-Central Area
Brown Flooring
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
30 Carpet Adhesive
30-MG7-105 Unit 114 - SW Office Tan Carpet Mastic
None Detected 30-MG7-106 Unit 114 - NE Area Tan Carpet Mastic
30-MG7-107 Unit 114 - West-Central Office Tan Carpet Mastic
31 Carpet Adhesive
31-MG7-108 Unit 112 - SE Area Tan Carpet Mastic
None Detected 31-MG7-109 Unit 112 - NE Area Tan Carpet Mastic
31-MG7-110 Unit 112 - NW Area Tan Carpet Mastic
32 Concrete Slab
32-CP5-111 Unit 116A - NE Room, Central Area Grey Concrete Slab
None Detected 32-CP5-112 Unit 114 - NE Area Grey Concrete Slab
32-CP5-113 Unit 102 - East Area Grey Concrete Slab
Tan Fiber-Reinforced Panel
Mastic
33-MG8-114 Unit 116B - South Wall, West of Door
White Fiberglass
Reinforced Plastic
None Detected
Tan Mastic
33-MG8-115 Unit 116B - South Wall, West of Door
White Fiberglass
Reinforced Plastic
Tan Mastic
33-MG8-116 Unit 116B - South Wall, East of Door
White Fiberglass
Reinforced Plastic
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
34 Black Wall Mastic
34-MG5-117 Unit 106 - South Wall, near Door Black Mastic 5% Chrysotile
34-MG5-118 Unit 106 - South Wall, near Door Black Mastic 5% Chrysotile
34-MG5-119 Unit 108 - South Wall, near Door Black Mastic 5% Chrysotile
35 Tan Wall Mastic
35-MG5-120 Unit 108 - South Wall Tan Mastic
None Detected 35-MG5-121 Unit 106 - South Wall Tan Mastic
35-MG5-122 Unit 106 - South Wall Tan Mastic
36 Blown-In Insulation
36-AW2-123 Unit 112/114 - Dividing Wall, Central Area Grey Insulation
None Detected 36-AW2-124 Unit 112/114 - Dividing Wall, Central Area Grey Insulation
36-AW2-125 Unit 112/114 - Dividing Wall, Central Area Grey Insulation
Interior Concrete Block
Mortar
37-MA2-126 Unit 104 - West Wall, near Door Grey Mortar
None Detected 37-MA2-127 Unit 114 - South Wall, near Door Grey Mortar
37-MA2-128 Unit 116A - South Wall, near Door Grey Mortar
38 Stone Wall Finish
38-MA6-129 Unit 104 - Exterior, West, Foundation Brown Cementitious Material
None Detected 38-MA6-130 Unit 116B - Exterior, East, near SE Corner Brown Cementitious Material
38-MA6-131 Unit 112 - Exterior, South, Foundation Brown Cementitious Material
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
39 Fluted-Stone Siding Mortar
39-MA3-132 Unit 104 - Exterior, West, North Column Grey Mortar
None Detected 39-MA3-133 Unit 104 - Exterior, North, Siding Grey Mortar
39-MA3-134 Unit 104 - Exterior, North, Storage Siding Grey Mortar
40 Concrete Block Mortar
40-MA2-135 Unit 104 - Exterior, North, at Storage Room Grey Mortar
None Detected 40-MA2-136 Unit 104 - Exterior, North, at Storage Room Grey Mortar
40-MA2-137 Unit 104 - Exterior, North, at Storage Room Grey Mortar
Drywall with Joint
Compound
41-WB5-138 Unit 116A - South Exterior, Awning Soffit
Brown/White Drywall
None Detected
White Joint Compound
Light Yellow Tape
41-WB5-139 Unit 110 - South Exterior, Awning Soffit
Brown/White Drywall
White Joint Compound
41-WB5-140 Unit 104 - South Exterior, Awning Soffit
Brown/White Drywall
White/Tan Joint Compound
42 Black Expansion Joint
42-MS5-141 Unit 104 - Exterior, West, South Area Black Expansion Joint
None Detected 42-MS5-142 Unit 104 - Exterior, West, South Area Black Expansion Joint
42-MS5-143 Unit 104 - Exterior, West, South Area Black Expansion Joint
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
Dark Brown Expansion
Joint
43-MS5-144 Unit 104 - Exterior, West, North Area Dark Brown Expansion Joint
None Detected 43-MS5-145 Unit 104 - Exterior, West, North Area Dark Brown Expansion Joint
43-MS5-146 Unit 116B - Exterior, South, East Area Dark Brown Expansion Joint
44 Roofing Material
44-RF5-147 Roof - NE Area
White Roofing Membrane
None Detected
Black/Brown Roofing Mastic
(Adhered to Membrane)
Black Roofing Tar
Black Roofing Felt
Brown Fiberboard
44-RF5-148 Roof - West-Central Area
White Roofing Membrane
Black/Brown Roofing Mastic
(Adhered to Membrane)
Black Roofing Tar
Yellow Insulation
44-RF5-149 Roof - SE Area
White Roofing Membrane
Black/Brown Roofing Mastic
(Adhered to Membrane)
Black Roofing Tar
Black Roofing Felt
Brown Fiberboard
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
45 Brick Caulk
45-CA3-150 Roof - NW Area, West Wall Grey Caulk
None Detected 45-CA3-151 Roof - SE Area, South Wall Grey Caulk
45-CA3-152 Roof - SE Area, South Wall Grey Caulk
46 Sealant
46-RF7-153 Roof - West Area, on HVAC Black/Grey Sealant 15% Chrysotile
46-RF7-154 Roof - West Area, on HVAC Black/Grey Sealant 15% Chrysotile
46-RF7-155 Roof - West Area, on HVAC Black/Grey Sealant 15% Chrysotile
47 Black Sealant
47-RF7-156 Roof - Central Area, on Vent Black Sealant
None Detected 47-RF7-157 Roof - Central Area, on Vent Black Sealant
47-RF7-158 Roof - Central Area, on Vent Black Sealant
48 Tar Sealant
48-RF4-159 Roof - NNW Area, on Pipe
Black Sealant
None Detected
White Sealant (Thin Layer)
48-RF4-160 Roof - West-Central Area, on Pipe
Black Sealant
White Sealant (Thin Layer)
48-RF4-161 Roof - East Area, on Pipe
Black Sealant
White Sealant (Thin Layer)
Asbestos-containing materials in BOLD.
Italics - Materials containing 1% or less asbestos.
* - Joint Compound containing <1% asbestos was captured in samples of wallpaper. This material in sample 07-SG5-34 was identified in HA 01 as an integral part of the wallboard system, which was determined through composite analysis to contain
<1% asbestos.
Appendix C
Asbestos Laboratory Analytical Results
Approved by:
Approved Signatory Frank Ehrenfeld
Report for:
Ryan Slanczka Terracon Consultants- Lenexa 15620 W. 113th St Lenexa, KS 66219
Regarding:
Eurofins Built Environment Testing East, LLC Project: 02237230 - 102-116 S Clairborne Rd
EML ID: 4069865
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
Eurofins Built Environment Testing East, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM (Layer %): 05-19-2025 and 05-20-2025
Service SOPs: Asbestos PLM (Layer %) (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EB-AS-S- 1267) NVLAP Lab Code 101165-0
EMLab ID: 4069865, Page 1 of 30Eurofins Built Environment Testing East, LLC
Eurofins Built Environment Testing East, LLC 9000 Commerce Parkway, Suite B, Mount Laurel, NJ 08054
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 102-116 S Clairborne Rd
Date of Receipt: 05-13-2025 Date of Report: 05-20-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
01-WB5-01. Drywall with Joint Compound; 114 - East Wall, Center 20288449-1
Layer 1 White Drywall with Brown Paper Homogeneity:Good
Not Detected 87% Non-Fibrous Material 10% Cellulose 3% Glass Fibers
Layer 2 White Joint Compound Homogeneity:Good
< 1% Chrysotile 100% Non-Fibrous Material
Layer 3 White Tape Homogeneity:Good
Not Detected 100% Cellulose
Composite Asbestos < 1%
01-WB5-02. Drywall with Joint Compound; 114 - SW Office, West Wall 20288450-1
Layer 1 White Drywall with Brown Paper Homogeneity:Good
Not Detected 87% Non-Fibrous Material
Homogeneity:Good
Not Detected 100% Cellulose
Composite Asbestos < 1%
01-WB5-03. Drywall with Joint Compound; 112 - NE Area, West Wall, near NW Room Door 20288451-1
Layer 1 White Drywall with Brown Paper Homogeneity:Good
Not Detected 90% Non-Fibrous Material
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
Comments:
EMLab ID: 4069865, Page 2 of 30Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 102-116 S Clairborne Rd
Date of Receipt: 05-13-2025 Date of Report: 05-20-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
01-WB5-04. Drywall with Joint Compound; 116A - NW Office, North Wall 20288452-1(cont.)
Layer 1 White Drywall with Brown Paper Homogeneity:Good
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
01-WB5-05. Drywall with Joint Compound; 116B - South Room, West Wall, South Area 20288453-1
Layer 1 White Drywall with Brown Paper Homogeneity:Good
Not Detected 100% Non-Fibrous Material
Tan Drywall with Brown Paper Homogeneity:Good
Not Detected 87% Non-Fibrous Material
01-WB5-06. Drywall with Joint Compound; 108 - North Hallway, West Wall, near North Door 20288454-1
Layer 1 White Drywall with Brown Paper Homogeneity:Good
Not Detected 87% Non-Fibrous Material
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
01-WB5-07. Drywall with Joint Compound; 102 - South Wall, Central Area 20288455-1
Layer 1 White Drywall with Brown Paper Homogeneity:Good
Not Detected 87% Non-Fibrous Material
Homogeneity:Good
< 1% Chrysotile 100% Non-Fibrous Material
Composite Asbestos < 1%
Comments:
EMLab ID: 4069865, Page 3 of 30Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 102-116 S Clairborne Rd
Date of Receipt: 05-13-2025 Date of Report: 05-20-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
01-WB5-08. Drywall with Joint Compound; 104 - SW Room, North Interior Wall 20288456-1(cont.)
Layer 1 White Drywall with Brown Paper Homogeneity:Good
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
02-PL1-09. Orange-Peel Wall Texture; 112 - North Hallway, South Wall 20288457-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
02-PL1-10. Orange-Peel Wall Texture; 112 - NW Restroom, West Wall 20288458-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
02-PL1-11. Orange-Peel Wall Texture; 112 - NW Area, North Wall 20288459-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
02-PL1-12. Orange-Peel Wall Texture; 112 - West Wall, Central Area 20288460-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
02-PL1-13. Orange-Peel Wall Texture; 112 - East Wall, Central Area 20288461-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
034-PL1-1. Orange-Peel Wall Texture; 102 - East Wall 20288462-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
03-PL1-15. Orange-Peel Wall Texture; 102 - NE Room, West Wall 20288463-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
03-PL1-16. Orange-Peel Wall Texture; 102 - SE Room, East Wall 20288464-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
03-PL1-17. Orange-Peel Wall Texture; 102 - West Area, South Wall 20288465-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
03-PL1-18. Orange-Peel Wall Texture; 102 - West Area, North Wall 20288466-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
Comments:
EMLab ID: 4069865, Page 4 of 30Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 102-116 S Clairborne Rd
Date of Receipt: 05-13-2025 Date of Report: 05-20-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
04-PL1-19. Knockdown Wall Texture;
104 - South Area, North Wall 20288467-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
04-PL1-20. Knockdown Wall Texture;
104 - West Area, South Wall 20288468-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
04-PL1-21. Knockdown Wall Texture;
104 - North Hallway, North Wall 20288469-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
04-PL1-22. Knockdown Wall Texture;
104 - NE Restroom, South Wall 20288470-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
04-PL1-23. Knockdown Wall Texture;
104 - East Area, East Wall 20288471-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL1-24. Thick Knockdown Wall Texture; 116A - NW Restroom, North Wall 20288472-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL1-25. Thick Knockdown Wall Texture; 116A - NE-Central Room, East Wall 20288473-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL1-26. Thick Knockdown Wall Texture; 116A - South Room, East Wall, Central Area 20288474-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL1-27. Thick Knockdown Wall Texture; 116A - South Room, West Wall, Central Area 20288475-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL1-28. Thick Knockdown Wall Texture; 116A - SW Office, North Wall 20288476-1
Layer 1 White Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
06-SG5-29. Wallpaper; 108 - North Hallway, North Closet, North Wall 20288477-1
Layer 1 Gray Wallpaper Homogeneity:Good
Not Detected 55% Cellulose 45% Non-Fibrous Material
06-SG5-30. Wallpaper; 108 - North Hallway, North Closet, East Wall 20288478-1
Layer 1 Gray Wallpaper Homogeneity:Good
Comments:
EMLab ID: 4069865, Page 5 of 30Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 102-116 S Clairborne Rd
Date of Receipt: 05-13-2025 Date of Report: 05-20-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
06-SG5-31. Wallpaper; 108 - North Hallway, North Closet, West Wall 20288479-1
Layer 1 Gray Wallpaper Homogeneity:Good
07-SG5-32. Wallpaper; 106 - South Area, West Wall 20288480-1
Layer 1 Gray Wallpaper Homogeneity:Good
Not Detected 85% Cellulose 15% Non-Fibrous Material
07-SG5-33. Wallpaper; 106 - South
20288481-1
Layer 1 Gray Wallpaper Homogeneity:Good
07-SG5-34. Wallpaper; 106 - South
20288482-1
Layer 1 Gray Wallpaper Homogeneity:Good
Homogeneity…