12-Asbestos Survey - Tract 51 (118-126 S. Clairborne).pdf

PDF 2 MB Posted

Attached to
I-35 and Santa Fe Street Fiber Optic Interconnect
Solicitation number
3-C-025-18
Issued by
Johnson County, Kansas

View the file

Other files

File Type Posted
4-3C02518 Fiber Optic Relocation.pdf PDF
3-304 Highway Permit.pdf PDF
2-310 Highway Permit Bridges.pdf PDF
1-Santa Fe Fiber Optic Interconnect Plans 2026-09-03.pdf PDF
19-Terracon ESA Standard Report - Tract 16.pdf PDF
15-Terracon ESA Standard Report - Tract 13.pdf PDF
18-Terracon ESA Standard Report - Tract 14.pdf PDF
31-Entry to Buildings.pdf PDF
28-Asbestos Survey Report - Tract 20.pdf PDF
3-Asbestos Survey Report - Tract 14.pdf PDF
4-Asbestos Survey Report - Tract 15.pdf PDF
5-Asbestos Survey Report - Tract 16.pdf PDF
9-Asbestos Survey Report - Tract 74.pdf PDF
1-Building Demo and Site Restoration Phase 2.pdf PDF
24-Terracon ESA Standard Report - Tract 74.pdf PDF
17-Terracon ESA Standard Report - Tract 47.pdf PDF
16-Terracon ESA Standard Report - Tract 20.pdf PDF
23-Terracon ESA Standard Report - Tract 76.pdf PDF
20-Terracon ESA Standard Report - Tract 79.pdf PDF
27-Terracon ESA Standard Report - Tract 18.pdf PDF
30-Santa Fe - Demo Plans Package 2.pdf PDF
2-Asbestos Survey Report - Tract 13.pdf PDF
29-Asbestos Survey Report - Tract 47.pdf PDF
14-Terracon ESA Standard Report - Tract 21.pdf PDF
6-Asbestos Survey Report - Tract 21.pdf PDF
13-Asbestos Survey Report - Tract 46.pdf PDF
10-Asbestos Survey Report - Tract 17.pdf PDF
21-Terracon ESA Standard Report - Tract 17.pdf PDF
7-Asbestos Survey Report - Tract 18.pdf PDF
22-Terracon ESA Standard Report - Tract 15.pdf PDF
12-Asbestos Survey Report - Tract 79.pdf PDF
8-Asbestos Survey Report - Tract 23.pdf PDF
26-Terracon ESA Standard Report - Tract 46.pdf PDF
11-Asbestos Survey Report - Tract 76.pdf PDF
25-Terracon ESA Standard Report - Tract 23.pdf PDF
15-Terracon ESA Standard Report - Tract 19.pdf PDF
20-Bid Tab 3C02518 Demolition.pdf PDF
8-Pre Bid Meeting.pdf PDF
6-Building and Demolition Contract.pdf PDF
14-Terracon ESA Standard Report - Tract 51 (Townsquare).pdf PDF
10-S - General Special Conditions REV.pdf PDF
5-Z Asbestos Survey - 189 S. Rogers Rd. - 02237230.pdf PDF
3-Z Asbestos Survey - 1904 E. Santa Fe St. - 02237230.pdf PDF
2-Z Asbestos Survey - 102-120 N. Clairborne Rd. - 02237230.pdf PDF
13-Terracon ESA Standard Report - Tract 75A.pdf PDF
1-Z Asbestos Survey - 1990 E. Santa Fe St. - 02237230.pdf PDF
16-Asbestos Survey - Tract 51 (128-140 S. Clairborne).pdf PDF
19-Bid Opening.pdf PDF
7-Z Terracon ESA Standard Report - 02237230 - Vape-Liberty Tax (1990 E Santa Fe).pdf PDF
9-Demo Plan Sheet Tract 51 Rev1.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Facilities | Environmental | Geotechnical | Materials I

City of Olathe Public Improvements

Asbestos Survey

Townsquare Shopping Center - Building 6

118-126 South Clairborne Road

Olathe, Kansas 66062

August 18, 2025 | Terracon Project Number: 02237230

Prepared for:

City of Olathe Kansas

100 East Santa Fe Street

Olathe, KS 66061

15620 W 113th Street

Lenexa, KS 66219

P (913) 492-7777

F (913) 492-7443

Terracon.com

Facilities | Environmental | Geotechnical | Materials i

August 18, 2025

City of Olathe, Kansas

100 East Santa Fe Street

Olathe, KS 66061

Attn: Ms. Therese Vink

P: (913) 971-9032

E: tmersmann@olatheks.org

Re: City of Olathe Public Improvements Asbestos Survey

Townsquare Shopping Center - Building 6

118-126 South Clairborne Road

Olathe, Kansas 66062

Terracon Project No: 02237230

Dear Ms. Vink:

Terracon Consultants, Inc. (Terracon) is pleased to provide the City of Olathe, Kansas, with this report regarding an asbestos survey conducted at the above-referenced location in Olathe, Kansas.

Asbestos

Asbestos was identified at a concentration greater than 1% in samples collected from the following materials:

Material Description Material Location

NESHAP

Category

Estimated

Quantity

Faux-Brick Vinyl Sheet Wall Unit 126 - NE-Central

Hallway, East Restroom

Category I

Nonfriable 64 Square Feet

Grey Mortar with Remnant Sheet Floor Backing associated with 4" x 9" Ceramic Floor Tile with Grout and Mortar

Unit 118 - Dining Room, Bar West Entryway

Category II Nonfriable

13 Square Feet

Tan Floor Tile and Black Mastic associated with 12" x 12" Tan Floor Tile with Tan Mastic

Unit 126 - SE Hallway, NE Room

Category I Nonfriable

20 Square Feet

City of Olathe Public Improvements Asbestos Survey

Townsquare Shopping Center - Building 6 | Olathe, Kansas

August 18, 2025 | Terracon Project No. 02237230

Facilities | Environmental | Geotechnical | Materials ii

Material Description Material Location

NESHAP

Category

Estimated

Quantity

Brick Caulk Roof - NW Area, West Wall Category II Nonfriable

10 Linear Feet

Flashing Sealant Roof - NW Area, on Vent

Pipe, NW Corner, SW Corner Category I Nonfriable

46 Linear Feet

Tar Sealant

Roof - NE Area, on Pipe;

North-Central Area, on Pipe;

South Area, on HVAC

Category I Nonfriable

594 Linear Feet

Notes: NESHAP – National Emission Standards for Hazardous Air Pollutants

Please refer to Section 3.0 of the attached report for a detailed description of the asbestos survey, sampling activities, and findings.

Terracon appreciates the opportunity to provide this service to the City of Olathe, Kansas. If you have any questions regarding this report, please contact our office at

913-492-7777.

Sincerely, Terracon

Ryan Slanczka Clark Grisell

Senior Staff Scientist Environmental Group Manager

Building Environmental Sciences

Ryan Slanczka Clark Grisell

Facilities | Environmental | Geotechnical | Materials iii

Table Of Contents

1.0 Introduction 1

1.1 Reliance 1

2.0 Building Description 1

3.0 Asbestos-Containing Materials Survey 1

3.1 Visual Assessment 2

3.2 Physical Assessment 2

3.3 Sample Collection 2

3.4 Sample Analysis 2

3.5 Regulatory Overview 3

3.6 Findings 3

4.0 General Comments 4

Appendices

Appendix A Asbestos-Containing Materials By Homogeneous Area

Appendix B Asbestos Survey Sample Location Summary

Appendix C Asbestos Laboratory Analytical Results

Appendix D Certifications

Facilities | Environmental | Geotechnical | Materials 1

1.0 Introduction

Terracon Consultants, Inc. (Terracon) conducted an asbestos-containing material survey of the Townsquare Shopping Center - Building 6 located at 118-126 South Clairborne

Road in Olathe, Kansas, on May 15, 2025. Building areas were visually assessed for suspect asbestos-containing materials (ACM). A reasonable effort was made to inspect accessible areas. Additional suspect materials could be present in walls, voids, or other concealed areas.

1.1 Reliance

This report is for the exclusive use of the City of Olathe, Kansas, for the project being discussed. Reliance by any other party on this report is prohibited without the written authorization of Terracon and the City of Olathe, Kansas.

2.0 Building Description

The subject building is an approximately 16,000-square-foot, single-story community shopping center (with exterior metal canopy), reportedly constructed in 1975. Interior flooring finishes include faux-wood planks, ceramic tiles, sheet vinyl, carpeting, and vinyl tiles over concrete. Interior walls throughout the building are drywall/joint compound wallboard, with acoustic texture, wallpaper, and ceramic tile finishes in various areas. Perimeter walls throughout the building are concrete block and concrete block with concrete wall texture. The primary, observable ceiling system is a drop, grid ceiling with lay-in acoustic tiles below a metal deck. The building’s exterior has concrete block and fluted-block siding. The roof consists of a single-ply synthetic rubber membrane system.

3.0 Asbestos-Containing Materials Survey

The survey was conducted by Mr. Ryan Slanczka and Mr. Blake Harris, State of Kansas-accredited asbestos inspectors. Copies of the asbestos inspectors’ accreditations are attached as Appendix D. The survey was conducted in general accordance with the sample collection protocols established in the United States Environmental Protection

Agency (USEPA) 40 Code of Federal Regulations (CFR) Part 763 Subpart E 763.86, the

Asbestos Hazard Emergency Response Act (AHERA). A summary of survey activities is provided below.

Facilities | Environmental | Geotechnical | Materials 2

3.1 Visual Assessment

Survey activities were initiated with visual observation of the interior and exterior of the building to identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of a building material that appears similar throughout in terms of color and texture, with consideration given to the date of application. The assessment was conducted in visually accessible areas of the building scheduled for renovation.

3.2 Physical Assessment

A physical assessment of each HA of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material that can be crumbled, pulverized, or reduced to powder by hand pressure when dry.

Friability was assessed by physically touching suspect materials.

3.3 Sample Collection

Based on the results of the visual observation, bulk samples of suspect ACM samples were collected in general accordance with USEPA AHERA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each homogeneous area. Bulk samples were collected using wet methods, as applicable, to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

Rubber, wood products, plastic products, glass, and steel are not considered suspect

ACM and were, therefore, not sampled. The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content. Terracon collected 160 bulk samples from 51 homogeneous areas of suspect ACM.

3.4 Sample Analysis

Bulk samples were submitted under chain of custody to Eurofins International Asbestos

Testing Laboratories (Eurofins) of Mount Laurel, New Jersey, for analysis by PLM with dispersion staining techniques per USEPA Method 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. Eurofins is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), Accreditation No. 101165.

Facilities | Environmental | Geotechnical | Materials 3

3.5 Regulatory Overview

The asbestos National Emission Standards for Hazardous Air Pollutants (NESHAP) regulation (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

The asbestos NESHAP regulation classifies ACM as regulated asbestos-containing materials (RACM), Category I non-friable ACM, or Category II non-friable ACM. RACM includes all friable ACM; Category I non-friable ACM that has become friable or will be or has been subjected to sanding, grinding, cutting, or abrading; and Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder in the course of renovation or demolition activity. Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering mastics, and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. Category II non-friable ACM generally includes but is not limited to cementitious material such as cement pipes, cement siding, cement panels, glazing, mortar, and grouts.

The Kansas Department of Health and Environment’s (KDHE) Asbestos Control Section within the Bureau of Air enforces the Asbestos NESHAP as adopted by reference at

Kansas Administrative Regulations (K.A.R.) 28-19-735. The owner or operator must provide KDHE with written notification at least 10 working days prior to the commencement of asbestos abatement activities that will disturb RACM in amounts greater than or equal to 10 square feet or 25 linear feet.

The United States Occupational Safety and Health Administration (USOSHA) asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard classifies construction and maintenance activities that could disturb ACM and specifies work practices and precautions that employers must follow when engaging in each class of regulated work. The standard also specifies requirements for handling materials containing asbestos in concentrations less than or equal to one percent.

3.6 Findings

Asbestos was identified at a concentration greater than 1% in samples collected from the following materials:

Facilities | Environmental | Geotechnical | Materials 4

Material Description Material Location

NESHAP

Category

Estimated

Quantity

Faux-Brick Vinyl Sheet Wall Unit 126 - NE-Central

Hallway, East Restroom Category I Nonfriable

64 Square Feet

Grey Mortar with Remnant Sheet Floor Backing associated with 4" x 9" Ceramic Floor Tile with Grout and Mortar

Unit 118 - Dining Room, Bar West Entryway

Category II Nonfriable

13 Square Feet

Tan Floor Tile and Black Mastic associated with 12" x 12" Tan

Floor Tile with Tan Mastic

Unit 126 - SE Hallway, NE Room

Category I Nonfriable

20 Square Feet

Brick Caulk Roof - NW Area, West Wall Category II Nonfriable

10 Linear Feet

Flashing Sealant Roof - NW Area, on Vent

Pipe, NW Corner, SW Corner Category I Nonfriable

46 Linear Feet

Tar Sealant Roof - NE Area, on Pipe;

North-Central Area, on Pipe;

South Area, on HVAC

Category I Nonfriable

594 Linear Feet

Notes: NESHAP – National Emission Standards for Hazardous Air Pollutants

The above-listed Category I non-friable ACM that is damaged or could be damaged to the extent that it could be crumbled, pulverized, or reduced to powder when dry, making it friable, must be removed prior to any activities (renovation and/or demolition) that may disturb this material in accordance with applicable federal, state, and local regulations. Terracon recommends that all ACM be removed by an abatement contractor prior to any demolition or renovation work that may disturb it.

The above-listed Category II non-friable ACM that has a high probability of becoming crumbled, pulverized, or reduced to powder when dry, making it friable, must be properly removed prior to any activities (renovation and/or demolition) that may disturb this material in accordance with applicable federal, state, and local regulations. USEPA believes that most demolition activities will subject Category II non-friable ACM to the asbestos NESHAP regulation.

Asbestos was not detected at a concentration of 1% or less in any samples collected from the subject building.

A summary of identified asbestos-containing materials by homogeneous area is included in Appendix A. A summary of sample locations is included in Appendix B. Laboratory analytical reports are included in Appendix C.

4.0 General Comments

Terracon did not perform sampling that required demolition or destructive activities such as dismantling of equipment or removal of protective coverings. Reasonable efforts to

Facilities | Environmental | Geotechnical | Materials 5 access suspect materials within known areas of restricted access (e.g., crawl spaces) were made; however, confined spaces or areas that may pose a health or safety risk to

Terracon personnel were not sampled. Sampling did not include suspect materials that could not be safely reached with available ladders or manlifts. Terracon did not sample suspect materials that may be present in movable equipment such as freezers, kitchen equipment, and hoods. Terracon typically investigates for flooring beneath carpeting by lifting small corner sections of carpet. If tiles or sheet vinyl were seen, they have been identified in the report. If tiles or sheet vinyl were not seen at corners under the carpet, it does not imply that there is none beneath the carpeted floor. Terracon did not conduct a destructive investigation of the doors in the building to determine if the doors were insulated for fire-rating purposes.

This survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during Terracon’s survey of the building. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by the City of Olathe, Kansas, and is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in the preparation of this report. No warranty, express or implied, is made.

Appendix A

Asbestos-Containing Materials By Homogeneous Area

Appendix A

Identified Asbestos-Containing Materials By Homogeneous Area (HA)

118-126 South Clairborne Road, Olathe, Kansas

Terracon Project No. 02237230

HA Material Description Material Location % and Type

Asbestos*

NESHAP

Classification Condition

Estimated

Quantity**

13 Faux-Brick Vinyl Sheet Wall Unit 126 - NE-Central

Hallway, East Restroom

Tan Sheet Flooring (wall) - 25% Chrysotile

Tan Mastic - None Detected

Category I Nonfriable

Good

Square Feet

Grey Mortar with Remnant Sheet Floor Backing associated with 4" x 9" Ceramic Floor Tile with

Grout and Mortar

Unit 118 - Dining Room, Bar West Entryway

Orange/Brown Ceramic Tile - None Detected

Grey Grout - None Detected Grey Mortar with Remnant Sheet Floor Backing - 5%

Chrysotile

Category II Nonfriable

Good

Square Feet

Tan Floor Tile and Black Mastic associated with 12" x 12" Tan Floor Tile with Tan

Mastic

Unit 126 - SE Hallway, NE Room

Tan Floor Tile - 2% Chrysotile Tan Mastic - None Detected Black Mastic - 2% Chrysotile

Category I Nonfriable

Good

Square Feet

49 Brick Caulk Roof - NW Area, West Wall Black Caulk - 10% Chrysotile

Tan/White Caulk - None Detected

Category II Nonfriable

Good

Linear Feet

50 Flashing Sealant Roof - NW Area, on Vent

Pipe, NW Corner, SW Corner

Black Roof Flashing with Grey/White Outer Coating -

10% Chrysotile Black Roof Flashing with Tan

Coating - 10% Chrysotile

Category I Nonfriable

Good

Linear Feet

51 Tar Sealant Roof - NE Area, on Pipe;

North-Central Area, on

Pipe; South Area, on HVAC

Black Tar Sealant with White Coating - 10% Chrysotile Black Tar Sealant - None

Detected

Category I Nonfriable

Good

Linear Feet

*% & Type Asbestos – this column contains both the analytical result of the sample with the highest concentration of asbestos detected in the samples that make up the HA, and the types of asbestos identified.

**Estimated quantities – quantities based on a cursory field evaluation, and actual quantities may vary significantly, especially if asbestos-containing materials are present in hidden and/or inaccessible areas not evaluated as part of this survey. This is not a bidding document; contractors are responsible for determining their own opinion of quantities.

Appendix B

Asbestos Survey Sample Location Summary

Appendix B

Asbestos Survey Sample Location Summary

118-126 South Clairborne Road, Olathe, Kansas

Terracon Project No. 02237230

HA

No.

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

Drywall with Joint

Compound

01-WB5-01

Unit 122 - West Rooms, Central Area, Interior

Wall

Pink Drywall with Brown Paper

None Detected

White Joint Compound

01-WB5-02 Unit 126 - NE Room, East Wall

White Drywall with Brown Paper

White Joint Compound

01-WB5-03 Unit 120 A/B - West Room, South Wall

White Drywall with Brown Paper

White Joint Compound

01-WB5-04

Unit 118 - Dining Room, South Wall, Central

Area

White Drywall with Brown Paper

White Joint Compound

2 Knock-down Texture

02-PL1-05 Unit 122 - Restroom Hallway, East Wall White Texture

None Detected

02-PL1-06 Unit 126 - Primary Room, East Wall White Texture

02-PL1-07 Unit 122 - NE Restroom, Ceiling White Texture

02-PL1-08 Unit 126 - Primary Room, NW Entryway Wall White Texture

02-PL1-09 Unit 126 - Primary Room, SE Area, East Wall White Texture

3 Knock-down Texture

03-PL1-10 Unit 120 A/B - SE Room, West Wall White Texture

None Detected

03-PL1-11 Unit 120 A/B - SE Room, North Wall White Texture

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

3 Knock-down Texture 03-PL1-12 Unit 120 A/B - SE Room, East Wall White Texture None Detected

4 Orange-Peel Wall Texture

04-PL1-13 Unit 118 - NE Hallway, North Wall, West Area White Texture

None Detected 04-PL1-14 Unit 118 - NE Hallway, East Wall White Texture

04-PL1-15

Unit 118 - NE Hallway, South Wall, Central

Area White Texture

5 Ornate-Style Wallpaper

05-SG5-16

Unit 120 A/B - West Room, NE Area, North

Wall White Wallpaper

None Detected 05-SG5-17 Unit 120 A/B - West Room, NE Area, North

Wall Black/White Wallpaper

05-SG5-18

Unit 120 A/B - West Room, NE Area, North

Wall Black/White Wallpaper

6 Concrete Wall Texture

06-SC5-19 Unit 122 - NE Restroom, East Wall

White Cementitious Material

None Detected

White Texture

06-SC5-20 Unit 122 - East Room, East Wall

White Cementitious Material

White Texture

06-SC5-21

Unit 126 - NE-Central Room, NE Closet, East

Wall White Cementitious Material

06-SC5-22 Unit 126 - Primary Room, SW Corner Wall White Cementitious Material

06-SC5-23 Unit 120 A/B - East Hallway, East Wall White Cementitious Material

06-SC5-24 Unit 120B - Exterior, East, at Door Beige Cementitious Material

06-SC5-25 Unit 126 - Exterior, East, at Door Beige Cementitious Material

2' x 2' Ceiling Tile with

Pinholes and Divots

07-CT3-26 Unit 126 - NE Rooms Grey Ceiling Tile with White

Surface

None Detected 07-CT3-27 Unit 122 - East Room Grey Ceiling Tile with White

Surface

07-CT3-28 Unit 122 - Central Room, NW Area Grey Ceiling Tile with White

Surface

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

8 2' x 4' Plain Ceiling Tile

08-CT4-29 Unit 126 - NE Room Grey Ceiling Tile with White

Surface

None Detected 08-CT4-30 Unit 126 - East Hallway, South Room Grey Ceiling Tile with White

Surface

08-CT4-31 Unit 126 - Primary Room, SE Area Grey Ceiling Tile with White

Surface

2' x 4' Ceiling Tile with

Pinholes and Fissures

09-CT4-32 Unit 122 - West Rooms Grey Ceiling Tile with White

Surface

None Detected 09-CT4-33 Unit 126 - SE Restroom Grey Ceiling Tile with White

Surface

09-CT4-34 Unit 120 A/B - NE Room, Central Area Grey Ceiling Tile with White

Surface

10 2'x4' Fiberglass Ceiling Tile

10-CT4-35 Unit 126 - SE Hallway Yellow Ceiling Tile

None Detected 10-CT4-36 Unit 118 - Dining Room, NW Area Yellow Ceiling Tile

10-CT4-37 Unit 118 - Dining Room, SW Area White/Yellow Ceiling Tile

2' x 4' Ceiling Tile with

Pinholes and Divots

11-CT4-38 Unit 120 A/B - NE Room, Central Area Off-White Ceiling Tile

None Detected 11-CT4-39 Unit 118 - Dining Room, SW Area Off-White Ceiling Tile

11-CT4-40 Unit 118 - Kitchen, West Area Off-White Ceiling Tile

4" Cove Base with Tan

Mastic

12-FC3-41 Unit 122 - East Room, South Wall

Grey Cove Base

None Detected

Beige Mastic

12-FC3-42

Unit 120 A/B - West Room, West Area, Interior

Wall

Grey Cove Base

Beige Mastic

12-FC3-43 Unit 118 - Dining Room, Behind Bar, East Wall

Black Cove Base

Beige Mastic

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

Faux-Brick Vinyl Sheet

Wall

13-FC1-44

Unit 126 - NE Central Hallway, East

Restroom

Tan Sheet Flooring 25% Chrysotile

Tan Mastic None Detected

13-FC1-45

Unit 126 - NE Central Hallway, East

Restroom

Tan Sheet Flooring 25% Chrysotile

Tan Mastic None Detected

13-FC1-46

Unit 126 - NE Central Hallway, East

Restroom

Tan Sheet Flooring 25% Chrysotile

Tan Mastic None Detected

12" x 12" Ceramic Wall Tile with Grout and Mastic

14-MA5-47 Unit 126 - SE Hallway, East Restroom

Beige/Grey Ceramic Tile

None Detected

Light Brown Grout

Beige Mastic

14-MA5-48 Unit 126 - SE Hallway, East Restroom

Beige/Grey Ceramic Tile

Light Brown Grout

Beige Mastic

14-MA5-49 Unit 126 - SE Hallway, East Restroom

Beige/Grey Ceramic Tile with

Black Paint

Light Brown Grout

Beige Mastic

12" x 12" Ceramic Tile with

Grout and White Mortar 15-MA5-50 Unit 122 - North Restroom, Wall

Brown/Beige Ceramic Tile

None Detected Tan Grout

White Mortar

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

12" x 12" Ceramic Tile with

Grout and White Mortar

15-MA5-51 Unit 126 - Kitchen, NE Area, Floor

Grey Ceramic Tile

None Detected

White Grout

White/Grey Mortar

15-MA5-52 Unit 126 - Primary Room, SW Corner, Floor

Brown/Beige Ceramic Tile

Tan Grout

White Mortar

12" x 12" Ceramic Tile with

Grout and Grey Mortar

16-MA5-53 Unit 122 - NE Restroom, Baseboard

White/Red Ceramic Tile

None Detected

Tan Grout

Grey Mortar

16-MA5-54 Unit 126 - East Restroom Hallway, Floor

Off-White/Grey Ceramic Tile

Tan Grout

Grey Mortar

16-MA5-55 Unit 126 - Kitchen, East Area, Floor

Grey/Red Ceramic Tile

White Grout

Grey Mortar

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

4" x 9" Ceramic Floor

Tile with Grout and

Mortar

17-MA5-56

Unit 118 - Dining Room, Bar West

Entryway

Orange/Brown Ceramic Tile None Detected

Grey Grout None Detected

Grey Mortar with Remnant

Sheet Floor Backing 5% Chrysotile

17-MA5-57

Unit 118 - Dining Room, Bar West

Entryway

Orange/Brown Ceramic Tile None Detected

Grey Grout None Detected

Grey Mortar with Remnant

Sheet Floor Backing 5% Chrysotile

17-MA5-58

Unit 118 - Dining Room, Bar West

Entryway

Orange/Brown Ceramic Tile None Detected

Grey Grout None Detected

Grey Mortar with Remnant

Sheet Floor Backing 5% Chrysotile

16" x 16" Ceramic Floor

Tile with Grout and Mortar

18-MA5-59 Unit 118 - Dining Room, Bar South Entryway

Tan Ceramic Tile

None Detected

Tan Grout

Grey Mortar

18-MA5-60 Unit 118 - Dining Room, Bar South Entryway

Tan Ceramic Tile

Tan Grout

Grey Mortar

18-MA5-61 Unit 118 - Dining Room, Bar South Entryway

Tan Ceramic Tile

Tan Grout

Grey Mortar

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

12" x 12" Ceramic Floor

Tile with Grout and Mortar

19-MA5-62 Unit 118 - NE Hallway, West Area

Off-White/Grey Ceramic Tile

None Detected

Tan Grout

Grey Mortar

19-MA5-63 Unit 118 - NE Hallway, West Area

Off-White/Grey Ceramic Tile

Tan Grout

Grey Mortar

19-MA5-64 Unit 118 - NE Hallway, West Area

Off-White/Grey Ceramic Tile

Tan Grout

Grey Mortar

6" x 24" Faux-Wood Plank

Ceramic Floor Tile with

Grout and Mortar

20-MA5-65 Unit 118 - Vestibule

Grey/White Ceramic Tile

None Detected

Grey Grout

White Mortar

20-MA5-66 Unit 118 - Vestibule

Grey/White Ceramic Tile

Grey Grout

White Mortar

20-MA5-67 Unit 118 - Vestibule

Grey/White Ceramic Tile

Grey Grout

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

12" x 12" Faux-Stone

Plastic Floor Tile with Tan

Adhesive

21-FT2-68 Unit 122 - Restroom Hallway

Tan Floor Tile

None Detected

Tan Adhesive

21-FT2-69 Unit 126 - SE Restroom

Tan Floor Tile

Tan Adhesive

21-FT2-70 Unit 122 - NE Restroom

Tan Floor Tile

Tan Adhesive

12" x12" Tan Floor Tile with Tan Mastic

22-FT2-71 Unit 126 - SE Hallway, NE Room

Tan Floor Tile 2% Chrysotile

Tan Mastic None Detected

22-FT2-72 Unit 126 - SE Hallway, NE Room

Tan Floor Tile 2% Chrysotile

Tan Mastic None Detected

22-FT2-73 Unit 126 - SE Hallway, NE Room

Tan Floor Tile 2% Chrysotile

Tan Mastic None Detected

Black Mastic 2% Chrysotile

12" x 12" Red Floor Tile with Mastic

23-FT2-74 Unit 120 A/B - West Room, SE Area

Red Floor Tile

None Detected

Clear Mastic

Tan Mastic

23-FT2-75 Unit 120 A/B - West Room, SE Area

Red Floor Tile

Clear Mastic

Tan Mastic

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

12" x 12" Red Floor Tile with Mastic 23-FT2-76 Unit 120 A/B - West Room, SE Area

Red Floor Tile

None Detected Clear Mastic

Tan Mastic

24 Faux-CFT Sheet Flooring

24-FC1-77 Unit 126 - East-Central Office Restroom

Grey/Brown Sheet Flooring

None Detected

Grey/Yellow Mastic

24-FC1-78 Unit 126 - East-Central Office Restroom

Grey/Brown Sheet Flooring

Grey/Yellow Mastic

24-FC1-79 Unit 126 - East-Central Office Restroom

Grey/Brown Sheet Flooring

Grey/Yellow Mastic

Faux-Wood Plank Sheet

Flooring

25-FC1-80 Unit 120 A/B - East Hallway, near Restroom

Wood Grain/Brown Sheet Flooring

None Detected

Grey/Yellow Mastic

25-FC1-81 Unit 120 A/B - West Room, Central Area

Wood Grain/Brown Sheet Flooring

Grey/Yellow Mastic

25-FC1-82 Unit 120 A/B - West Room, South-Central Area

Wood Grain/Brown Sheet Flooring

Grey/Yellow Mastic

Yellow/Tan Carpet Glue with Residual Black Mastic

26-MG7-83

Unit 126 - Primary Room, SW Area, near SW

Entrance Yellow/Black Mastic

None Detected 26-MG7-84 Unit 122 - West Rooms, Central Area Yellow/Black Mastic

26-MG7-85 Unit 126 - Primary Room, East Area Yellow/Black Mastic

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

Tan/Yellow Carpet

Adhesive

27-MG7-86 Unit 120 A/B - West Room, SE-Central Area Tan Adhesive

None Detected 27-MG7-87 Unit 120 A/B - East-Central Office Tan Adhesive

27-MG7-88 Unit 120 A/B - West Room, NE Area Tan Adhesive

28 Light Tan Carpet Adhesive

28-MG7-89 Unit 120 A/B - West Room, East-Central Area Tan Adhesive

None Detected 28-MG7-90 Unit 120 A/B - West Room, ESE Area Tan Adhesive

28-MG7-91 Unit 120 A/B - West Room, East Area Tan Adhesive

29 Tan Flooring Adhesive

29-MG7-92 Unit 118 - Dining Room, West-Central Area Tan Adhesive

None Detected 29-MG7-93 Unit 118 - Dining Room, NE Area Tan Adhesive

29-MG7-94 Unit 118 - Dining Room, SW Area Tan Adhesive

30 Black Flooring Material

30-MG5-95 Unit 118 - Dining Room, Bar West Entryway Black Flooring Material

None Detected 30-MG5-96 Unit 118 - Dining Room, Bar West Entryway Black Flooring Material

30-MG5-97 Unit 118 - Dining Room, Behind Bar Black Flooring Material

31 Concrete Slab

31-CP5-98 Unit 118 - Dining Room, West-Central Area

Grey Concrete

None Detected

Tan Mastic

31-CP5-99 Unit 122 - Central Room, SW Area Grey Concrete

31-CP5-100 Unit 120B - West Room, North Area Grey Concrete

32 Brown Epoxy

32-FC2-101 Unit 120 A/B - West Room, West-Central Area Brown Coating Epoxy

None Detected 32-FC2-102 Unit 120 A/B - SE Room Brown Coating Epoxy

32-FC2-103 Unit 120 A/B - East Hallway, near Restroom Brown Coating Epoxy

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

33 Expansion Joint

33-MS5-104 Unit 120 A/B - SE Room, East Area White Expansion Joint

None Detected 33-MS5-105 Unit 120 A/B - SE Room, East Area White Expansion Joint

33-MS5-106 Unit 120 A/B - West Room, SE Area White Expansion Joint

Fiber-Reinforced Panel

Mastic

34-MG8-107 Unit 126 - NE Room, Walls Off-White Panel Mastic

None Detected 34-MG8-108 Unit 126 - NE Room, Walls Off-White Panel Mastic

34-MG8-109 Unit 126 - NE Room, Walls Off-White Panel Mastic

35 Wall Mastic

35-MG5-110

Unit 126 - Primary Room, West Area, Lower

Panels Brown Mastic

None Detected 35-MG5-111 Unit 126 - Primary Room, West Area, Lower

Panels Brown Mastic

35-MG5-112

Unit 126 - Primary Room, West Area, Lower

Panels Brown Mastic

36 Glue Puck

36-MG5-113

Unit 126 - Primary Room, SE Area, behind

Mirrors Tan Glue

None Detected 36-MG5-114 Unit 126 - Primary Room, SE Area, behind

Mirrors Tan Glue

36-MG5-115

Unit 126 - Primary Room, SE Area, behind

Mirrors Tan Glue

Batt Insulation with Paper

Backing

37-AW1-116 Unit 118 - Dining Room, NW Area

Yellow Insulation

None Detected

Tan/Black Paper

37-AW1-117 Unit 118 - Dining Room, SW Area

Yellow Insulation

Tan/Black Paper

37-AW1-118 Unit 118 - Dining Room, SE Area

Pink Insulation

Tan/Black Paper

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

Bar-Top Leveling

Compound

38-FC6-119 Unit 118 - Dining Room, Bar-Top White Joint Compound with

Greyish Paint

None Detected 38-FC6-120 Unit 118 - Dining Room, Bar-Top White Joint Compound with

Greyish Paint

38-FC6-121 Unit 118 - Dining Room, Bar-Top White Joint Compound with

Greyish Paint

39 Stone Wall Mortar

39-MA3-122 Unit 126 - Primary Room, South Wall Grey Mortar

None Detected 39-MA3-123 Unit 126 - Primary Room, South Wall Grey Mortar

39-MA3-124 Unit 126 - Primary Room, South Wall Grey Mortar

40 Glass Block Grout

40-MA4-125 Unit 126 - Primary Room, near SW Entryway Grey Grout

None Detected 40-MA4-126 Unit 126 - Primary Room, near SW Entryway Grey Grout

40-MA4-127 Unit 126 - Primary Room, near SW Entryway Grey Grout

41 Stone Wall Finish

41-MA6-128 Unit 126 - Exterior, West, Column Tan Cementitious Material Wall

Finish

None Detected 41-MA6-129 Unit 126 - Exterior, East, Siding Tan/Grey Cementitious Material

Wall Finish

41-MA6-130 Unit 120B - Exterior, West, Siding Tan Cementitious Material Wall

Finish

42 Fluted-Stone Siding Mortar

42-MA3-131 Unit 126 - Exterior, SW, Siding Grey Mortar

None Detected 42-MA3-132 Unit 120B - Exterior, West, Column Grey Mortar

42-MA3-133 Unit 120A - Exterior, West, Siding Grey Mortar

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

43 Concrete Block Mortar

43-MA2-134 Unit 120A - Exterior, East, at Door Grey Mortar

None Detected 43-MA2-135 Unit 118 - Dining Room, West Wall, South of

Vestibule Tan Mortar

43-MA2-136 Unit 122 - West Room, West Wall, near Door Tan Mortar

44 Corrugated-Fiber Panel

44-MS5-137 Unit 126 - Exterior, West, Awning Black Fiberboard Panel Painted

Red

None Detected 44-MS5-138 Unit 126 - Exterior, West, Awning Black Fiberboard Panel Painted

Red

44-MS5-139 Unit 126 - Exterior, West, Awning Black Fiberboard Panel Painted

Red

Drywall with Joint

Compound

45-WB5-140 Unit 118 - Exterior, West

White Drywall with Brown Paper

None Detected

White Joint Compound

45-WB5-141 Unit 122 - Exterior, West

White Drywall with Brown Paper

White Joint Compound

45-WB5-142 Unit 126 - Exterior, West

White Drywall with Brown Paper

White Joint Compound

Dark Brown Expansion

Joint

46-MS5-143 Unit 126 - Exterior, West Dark Brown Expansion Joint

None Detected 46-MS5-144 Unit 126 - Exterior, West Dark Brown Expansion Joint

46-MS5-145 Unit 126 - Exterior, West Dark Brown Expansion Joint

47 Black Expansion Joint

47-MS5-146 Unit 118 - Exterior, NW Corner Black Expansion Joint

None Detected 47-MS5-147 Unit 118 - Exterior, NW Corner Black Expansion Joint

47-MS5-148 Unit 118 - Exterior, NW Corner Black Expansion Joint

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

48 Roofing Material

48-RF5-149 Roof - NE Area

Black Roofing Material

None Detected

Black/White Roofing Membrane

Black Tar

Black Tar Paper

Black Roofing Felt

Tan Fiberboard

Yellow Insulation

48-RF5-150 Roof - West-Central Area

Black Roofing Material

Black/White Roofing Membrane

Black Tar

Black Tar Paper

Black Roofing Felt

Tan Fiberboard

Yellow Insulation

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

48 Roofing Material 48-RF5-151 Roof - SE Area

Black Roofing Material

None Detected

Black/White Roofing Membrane

Black Tar

Black Tar Paper

Black Roofing Felt

Tan Fiberboard

Yellow Insulation

49 Brick Caulk

49-CA3-152 Roof - NW Area, West Wall

Black Caulk 10% Chrysotile

Tan/White Caulk None Detected

49-CA3-153 Roof - NW Area, West Wall

Black Caulk 10% Chrysotile

Tan/White Caulk None Detected

49-CA3-154 Roof - NW Area, West Wall

Black Caulk 10% Chrysotile

Tan/White Caulk None Detected

50 Flashing Sealant

50-RF7-155 Roof - NE Area, on Vent Pipe Black Roof Flashing with

Grey/White Outer Coating 10% Chrysotile

50-RF7-156 Roof - NW Corner Black Roof Flashing with

Grey/White Outer Coating 10% Chrysotile

50-RF7-157 Roof - SW Corner Black Roof Flashing with Tan

Coating 10% Chrysotile

51 Tar Sealant

51-RF4-158 Roof - NE Area, on Pipe Black Tar Sealant with White

Coating 10% Chrysotile

51-RF4-159 Roof - North-Central Area, on Pipe Black Tar Sealant with White

Coating 10% Chrysotile

51-RF4-160 Roof - South Area, on HVAC Black Tar Sealant None Detected

Asbestos-containing materials in BOLD.

Appendix C

Asbestos Laboratory Analytical Results

Approved by:

Approved Signatory Frank Ehrenfeld

Report for:

Ryan Slanczka Terracon Consultants- Lenexa 15620 W. 113th St Lenexa, KS 66219

Regarding:

Eurofins Built Environment Testing East, LLC Project: 02237230 - 118-126 S Clairborne Rd

EML ID: 4077654

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins Built Environment Testing East, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM (Layer %): 05-27-2025 and 05-28-2025

Service SOPs: Asbestos PLM (Layer %) (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EB-AS-S- 1267) NVLAP Lab Code 101165-0

EMLab ID: 4077654, Page 1 of 27Eurofins Built Environment Testing East, LLC

Eurofins Built Environment Testing East, LLC 9000 Commerce Parkway, Suite B, Mount Laurel, NJ 08054

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 118-126 S Clairborne Rd

Date of Receipt: 05-19-2025 Date of Report: 05-28-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

01-WB5-01. Drywall with Joint Compound; 122-West Rooms, Central Area, Interior Wall 20330091-1

Layer 1 Pink Drywall with Brown Paper Homogeneity:Good

Not Detected 83% Non-Fibrous Material 15% Cellulose 2% Glass Fibers

Layer 2 White Joint Compound Homogeneity:Good

Not Detected 100% Non-Fibrous Material

01-WB5-02. Drywall with Joint Compound; 126-NE Room, East Wall 20330092-1

Layer 1 White Drywall with Brown Paper Homogeneity:Good

Not Detected 85% Non-Fibrous Material

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

01-WB5-03. Drywall with Joint Compound; 120 A/B-West Room, South Wall 20330093-1

Layer 1 White Drywall with Brown Paper Homogeneity:Good

Not Detected 83% Non-Fibrous Material

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

01-WB5-04. Drywall with Joint Compound; 118-Dining Room, South Wall, Central Area 20330094-1

Layer 1 White Drywall with Brown Paper Homogeneity:Good

Not Detected 83% Non-Fibrous Material

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

02-PL1-05. Knock-Down Texture;

122-Restroom Hallway, East Wall 20330095-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

02-PL1-06. Knock-Down Texture;

126-Primary Room, East Wall 20330096-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

02-PL1-07. Knock-Down Texture;

122-NE Restroom, Ceiling 20330097-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

02-PL1-08. Knock-Down Texture;

126-Primary Room, NE Entryway Wall 20330098-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4077654, Page 2 of 27Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 118-126 S Clairborne Rd

Date of Receipt: 05-19-2025 Date of Report: 05-28-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

02-PL1-09. Knock-Down Texture;

126-Primary Room, SE Area, East Wall 20330099-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

03-PL1-10. Knock-Down Texture;

120 A/B-SE Room, West Wall 20330100-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

03-PL1-11. Knock-Down Texture;

120 A/B-SE Room, North Wall 20330101-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

03-PL1-12. Knock-Down Texture;

120 A/B-SE Room, East Wall 20330102-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

04-PL1-13. Orange-Peel Wall Texture; 118-NE Hallway, North Wall, West Area 20330103-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

04-PL1-14. Orange-Peel Wall Texture; 118-NE Hallway, East Wall 20330104-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

04-PL1-15. Orange-Peel Wall Texture; 118-NE Hallway, South Wall, Central Area 20330105-1

Layer 1 White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

05-SG5-16. Ornate-Style Wallpaper;

120 A/B-West Room, NE Area, North Wall 20330106-1

Layer 1 White Wallpaper Homogeneity:Good

Not Detected 70% Non-Fibrous Material 30% Cellulose

05-SG5-17. Ornate-Style Wallpaper;

120 A/B-West Room, NE Area, North Wall 20330107-1

Layer 1 Black/White Wallpaper Homogeneity:Good

Not Detected 60% Non-Fibrous Material 40% Cellulose

05-SG5-18. Ornate-Style Wallpaper;

120 A/B-West Room, NE Area, North Wall 20330108-1

Layer 1 Black/White Wallpaper Homogeneity:Good

Not Detected 60% Non-Fibrous Material 40% Cellulose

06-SC5-19. Concrete Wall Texture;

122-NE Restroom, East Wall 20330109-1

Layer 1 White Cementitious Material Homogeneity:Good

Not Detected 90% Non-Fibrous Material 10% Glass Fibers

White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4077654, Page 3 of 27Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 118-126 S Clairborne Rd

Date of Receipt: 05-19-2025 Date of Report: 05-28-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

06-SC5-20. Concrete Wall Texture;

122-East Room, East Wall 20330110-1

Layer 1 White Cementitious Material Homogeneity:Good

10% Glass Fibers

White Texture Homogeneity:Good

Not Detected 100% Non-Fibrous Material

06-SC5-21. Concrete Wall Texture;

126-NE-CEntral Room, NE Closet, East Wall 20330111-1

Layer 1 White Cementitious Material Homogeneity:Good

Not Detected 90% Non-Fibrous Material 10% Glass Fibers

A

06-SC5-22. Concrete Wall Texture;

126-Primary Room, SW Corner Wall 20330112-1

Layer 1 White Cementitious Material Homogeneity:Good

Not Detected 90% Non-Fibrous Material 10% Glass Fibers

A

06-SC5-23. Concrete Wall Texture;

120 A/B-East Hallway, East Wall 20330113-1

Layer 1 White Cementitious Material Homogeneity:Good

Not Detected 90% Non-Fibrous Material 10% Glass Fibers

A

06-SC5-24. Concrete Wall Texture;

120B-Exterior, East, at Door 20330114-1

Layer 1 Beige Cementitious Material Homogeneity:Good

Not Detected 90% Non-Fibrous Material 10% Glass Fibers

A

06-SC5-25. Concrete Wall Texture;

126-Exterior, East, at Door 20330115-1

Layer 1 Beige Cementitious Material Homogeneity:Good

Not Detected 90% Non-Fibrous Material 10% Glass Fibers

A

07-CT3-26. 2'x2' Ceiling Tile w/ Pinholes & Divots; 126-NE Rooms 20330116-1

Layer 1 Gray Ceiling Tile with White Surface Homogeneity:Good

Not Detected 60% Cellulose 20% Glass Fibers 20% Non-Fibrous Material

07-CT3-27. 2'x2' Ceiling Tile w/ Pinholes & Divots; 122-East Room 20330117-1

Layer 1 Gray Ceiling Tile with White Surface Homogeneity:Good

Not Detected 60% Cellulose 20% Glass Fibers

07-CT3-28. 2'x2' Ceiling Tile w/ Pinholes & Divots; 122-Central Room, NW Area 20330118-1

Layer 1 Gray Ceiling Tile with White Surface Homogeneity:Good

Not Detected 50% Cellulose 30% Glass Fibers

08-CT4-29. 2'x4' Plain Ceiling Tile;

126-NE Room 20330119-1

Layer 1 Gray Ceiling Tile with White Surface Homogeneity:Good

Not Detected 50% Cellulose

08-CT4-30. 2'x4' Plain Ceiling Tile;

126-East Hallway, South Room 20330120-1

Layer 1 Gray Ceiling Tile with White Surface Homogeneity:Good

Not Detected 50% Cellulose

Comments: A)No other textured layer present. Cementitious material is textured.

EMLab ID: 4077654, Page 4 of 27Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 118-126 S Clairborne Rd

Date of Receipt: 05-19-2025 Date of Report: 05-28-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

08-CT4-31. 2'x4' Plain Ceiling Tile;

126-Primary Room, SE Area 20330121-1

Layer 1 Gray Ceiling Tile with White Surface Homogeneity:Good

Not Detected 50% Cellulose

09-CT4-32. 2'x4' Ceiling Tile w/ Pinholes & Fissures; 122-West Rooms 20330122-1

Layer 1 Gray Ceiling Tile with White Surface Homogeneity:Good

Not Detected 50% Cellulose 35% Glass Fibers 15% Non-Fibrous Material

09-CT4-33. 2'x4' Ceiling Tile w/ Pinholes & Fissures; 126-SE Restroom 20330123-1

Layer 1 Gray Ceiling Tile with White Surface Homogeneity:Good

Not Detected 50% Cellulose 35% Glass Fibers 15% Non-Fibrous Material

09-CT4-34. 2'x4' Ceiling Tile w/ Pinholes & Fissures; 120 A/B-NE Room, Central Area 20330124-1

Layer 1 Gray Ceiling Tile with White Surface Homogeneity:Good

Not Detected 50% Cellulose

10-CT4-35. 2'x4' Fiberglass Ceiling Tile; 126-SE Hallway 20330125-1

Layer 1 Yellow Ceiling Tile Homogeneity:Good

Not Detected 90% Glass Fibers 10% Non-Fibrous Material

10-CT436. 2'x4' Fiberglass Ceiling Tile; 118-Dining Room, NW Area 20330126-1

Layer 1 Yellow Ceiling Tile Homogeneity:Good

Not Detected 90% Glass Fibers

10-CT4-37. 2'x4' Fiberglass Ceiling Tile; 118-Dining Room, SW Area 20330127-1

Layer 1 White/ Yellow Ceiling Tile Homogeneity:Good

Not Detected 95% Glass Fibers 5% Non-Fibrous Material

11-CT4-38. 2'x4' Ceiling Tile w/ Pinholes & Divots; 120 A/B-NE Room, Central Area 20330128-1

Layer 1 Off-White Ceiling Tile Homogeneity:Good

Not Detected 60% Cellulose

11-CT4-39. 2'x4' Ceiling Tile w/ Pinholes & Divots; 118-Dining Room, SW Area 20330129-1

Layer 1 Off-White Ceiling Tile Homogeneity:Good

Not Detected 60% Cellulose

11-CT4-40. 2'x4' Ceiling Tile w/ Pinholes & Divots; 118-Kitchen, West Area 20330130-1

Layer 1 Off-White Ceiling Tile Homogeneity:Good

Not Detected 60% Cellulose

12-FC3-41. 4" Cove Base w/ Tan Mastic; 122-East Room, South Wall 20330131-1

Layer 1 Gray Cove Base Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4077654, Page 5 of 27Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 118-126 S Clairborne Rd

Date of Receipt: 05-19-2025 Date of Report: 05-28-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

12-FC3-42. 4" Cove Base w/ Tan Mastic; 120 A/B-West Room, West Area, Interior Wall 20330132-1

Layer 1 Gray Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

12-FC3-43. 4" Cove Base w/ Tan Mastic; 118-Dining Room, behind Bar, East Wall 20330133-1

Layer 1 Black Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

13-FC1-44. Faux-Brick Vinyl Sheet Wall; 126-NE Central Hallway, East Restroom 20330134-1

Layer 1 Tan Sheet Flooring

25% Chrysotile 75% Non-Fibrous Material

Homogeneity:Good

No…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .