16-Asbestos Survey - Tract 51 (128-140 S. Clairborne).pdf

PDF 2 MB Posted

Attached to
I-35 and Santa Fe Street Fiber Optic Interconnect
Solicitation number
3-C-025-18
Issued by
Johnson County, Kansas

About this file

This is an asbestos survey report prepared by Terracon Consultants, Inc. for the City of Olathe, Kansas, related to the Townsquare Shopping Center Building 7 located at 128-140 South Clairborne Road. The survey was conducted on May 15, 2025, to identify asbestos-containing materials (ACM) in the approximately 45,350-square-foot single-story commercial building constructed in 1975, which is scheduled for demolition and site restoration as part of project 3-C-025-18 near Santa Fe Street and I-35. Terracon collected 160 bulk samples from 51 homogeneous areas and identified significant quantities of asbestos-containing materials including 18,675 square feet of floor tile and mastic in Unit 140, 845 square feet of ceramic tile mastic in Unit 134B, and various other ACMs totaling approximately 20,500+ square feet of Category I non-friable materials and 73 square feet of Regulated Asbestos-Containing Material (RACM) requiring professional abatement.

The survey findings indicate that all identified RACM and Category I non-friable ACM must be removed by a State of Kansas licensed abatement contractor prior to any demolition or renovation activities, in accordance with federal NESHAP regulations and Kansas Administrative Regulations. The materials identified include floor tiles, mastics, sheet flooring, wall mastic, roofing materials, flashing sealants, and tar sealants containing 2% chrysotile asbestos, with additional materials containing 1% or less asbestos that are subject to OSHA workplace exposure limits. The report was prepared exclusively for the City of Olathe's use and includes detailed regulatory compliance requirements, noting that KDHE notification is required at least 10 working days prior to commencement of abatement activities for materials exceeding 10 square feet or 25 linear feet.

View the file

Other files

File Type Posted
4-3C02518 Fiber Optic Relocation.pdf PDF
3-304 Highway Permit.pdf PDF
2-310 Highway Permit Bridges.pdf PDF
1-Santa Fe Fiber Optic Interconnect Plans 2026-09-03.pdf PDF
19-Terracon ESA Standard Report - Tract 16.pdf PDF
15-Terracon ESA Standard Report - Tract 13.pdf PDF
18-Terracon ESA Standard Report - Tract 14.pdf PDF
31-Entry to Buildings.pdf PDF
28-Asbestos Survey Report - Tract 20.pdf PDF
3-Asbestos Survey Report - Tract 14.pdf PDF
4-Asbestos Survey Report - Tract 15.pdf PDF
5-Asbestos Survey Report - Tract 16.pdf PDF
9-Asbestos Survey Report - Tract 74.pdf PDF
1-Building Demo and Site Restoration Phase 2.pdf PDF
24-Terracon ESA Standard Report - Tract 74.pdf PDF
17-Terracon ESA Standard Report - Tract 47.pdf PDF
16-Terracon ESA Standard Report - Tract 20.pdf PDF
23-Terracon ESA Standard Report - Tract 76.pdf PDF
20-Terracon ESA Standard Report - Tract 79.pdf PDF
27-Terracon ESA Standard Report - Tract 18.pdf PDF
30-Santa Fe - Demo Plans Package 2.pdf PDF
2-Asbestos Survey Report - Tract 13.pdf PDF
29-Asbestos Survey Report - Tract 47.pdf PDF
14-Terracon ESA Standard Report - Tract 21.pdf PDF
6-Asbestos Survey Report - Tract 21.pdf PDF
13-Asbestos Survey Report - Tract 46.pdf PDF
10-Asbestos Survey Report - Tract 17.pdf PDF
21-Terracon ESA Standard Report - Tract 17.pdf PDF
7-Asbestos Survey Report - Tract 18.pdf PDF
22-Terracon ESA Standard Report - Tract 15.pdf PDF
12-Asbestos Survey Report - Tract 79.pdf PDF
8-Asbestos Survey Report - Tract 23.pdf PDF
26-Terracon ESA Standard Report - Tract 46.pdf PDF
11-Asbestos Survey Report - Tract 76.pdf PDF
25-Terracon ESA Standard Report - Tract 23.pdf PDF
15-Terracon ESA Standard Report - Tract 19.pdf PDF
20-Bid Tab 3C02518 Demolition.pdf PDF
12-Asbestos Survey - Tract 51 (118-126 S. Clairborne).pdf PDF
8-Pre Bid Meeting.pdf PDF
6-Building and Demolition Contract.pdf PDF
14-Terracon ESA Standard Report - Tract 51 (Townsquare).pdf PDF
10-S - General Special Conditions REV.pdf PDF
5-Z Asbestos Survey - 189 S. Rogers Rd. - 02237230.pdf PDF
3-Z Asbestos Survey - 1904 E. Santa Fe St. - 02237230.pdf PDF
2-Z Asbestos Survey - 102-120 N. Clairborne Rd. - 02237230.pdf PDF
13-Terracon ESA Standard Report - Tract 75A.pdf PDF
1-Z Asbestos Survey - 1990 E. Santa Fe St. - 02237230.pdf PDF
19-Bid Opening.pdf PDF
7-Z Terracon ESA Standard Report - 02237230 - Vape-Liberty Tax (1990 E Santa Fe).pdf PDF
9-Demo Plan Sheet Tract 51 Rev1.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Facilities | Environmental | Geotechnical | Materials I

City of Olathe Public Improvements

Asbestos Survey

Townsquare Shopping Center - Building 7

128-140 South Clairborne Road

Olathe, Kansas 66062

August 18, 2025 | Terracon Project Number: 02237230

Prepared for:

City of Olathe Kansas

100 East Santa Fe Street

Olathe, KS 66061

15620 W 113th Street

Lenexa, KS 66219

P (913) 492-7777

F (913) 492-7443

Terracon.com

Facilities | Environmental | Geotechnical | Materials i

August 18, 2025

City of Olathe, Kansas

100 East Santa Fe Street

Olathe, KS 66061

Attn: Ms. Therese Vink

P: (913) 971-9032

E: tmersmann@olatheks.org

Re: City of Olathe Public Improvements Asbestos Survey

Townsquare Shopping Center - Building 7

128-140 South Clairborne Road

Olathe, Kansas 66062

Terracon Project No: 02237230

Dear Ms. Vink:

Terracon Consultants, Inc. (Terracon) is pleased to provide the City of Olathe, Kansas, with this report regarding an asbestos survey conducted at the above-referenced location in Olathe, Kansas.

Asbestos

Asbestos was identified at a concentration greater than 1% in samples collected from the following materials:

Material Description Material Location

NESHAP

Category

Estimated

Quantity

Black Mastic associated with

6" x 6" Red Ceramic Floor Tile with Grout and Mortar

Unit 134B - NW-Central

Room, SW Room

Category I

Nonfriable

Square Feet

12" x 12" Beige with Tan Streaks

Floor Tile and Black Mastic

Unit 140 - Salesfloor, South

Breakroom, SE Office

Category I

Nonfriable

18,675

Square Feet

Black/Brown Mastic associated with 12" x 12" Beige Mottle Floor

Tile with Tan & Brown Mastic

Unit 140 - Salesfloor, Women’s Restroom

Category I Nonfriable

Included in Quantity of HA

City of Olathe Public Improvements Asbestos Survey

Townsquare Shopping Center - Building 7 | Olathe, Kansas

August 18, 2025 | Terracon Project No. 02237230

Facilities | Environmental | Geotechnical | Materials ii

Material Description Material Location

NESHAP

Category

Estimated

Quantity

Black Mastic associated with 12" x 12" Red Floor Tile

Unit 140 - Salesfloor Category I Nonfriable

Included in

Quantity of HA

12" x 12" Grey with Tan Streaks Floor Tile and Black Mastic

Unit 132 - Restroom Category I Nonfriable

Square Feet

12" x 12" Tan/Green Design-Print Floor Tile with Tan Mastic

Unit 134A - North Room Category I Nonfriable

Square Feet

Faux-CFT Sheet Flooring with

Paper Backing Unit 130B - Restrooms RACM

Square Feet

Black Mastic associated with Grey/Light Grey/Blue with Black and White Flecks Epoxy Flooring

Unit 132 - NE-Central Area, West-Central Area, SE Area

Category I Nonfriable

Square Feet

Black Wall Mastic Unit 140 - South Breakroom, West Wall Category I Nonfriable

Linear Feet

Roofing Material Roof - On East AHU over

Unit 128 Category I Nonfriable

Linear Feet

Flashing Sealant

Roof - NE Corner Breezeway Wall, East Perimeter Wall over Unit 128, South-Central Area Exhaust over Unit 140

Category I

Nonfriable

Linear Feet

Tar Sealant Roof - On Pipes over Units

138 and 140 Category I Nonfriable

Linear Feet

Notes: NESHAP – National Emission Standards for Hazardous Air Pollutants RACM - Regulated Asbestos-Containing Material

Asbestos was identified at a concentration of 1% or less in samples collected from the following materials:

Material Description Material Location

Joint Compound associated with Drywall Wallboard System

Throughout Subject Building

12" x 12" Red Floor Tile Unit 140 - Salesfloor

Please refer to Section 3.0 of the attached report for a detailed description of the asbestos survey, sampling activities, and findings.

Facilities | Environmental | Geotechnical | Materials iii

Terracon appreciates the opportunity to provide this service to the City of Olathe, Kansas. If you have any questions regarding this report, please contact our office at

913-492-7777.

Sincerely, Terracon

Ryan Slanczka Clark Grisell

Senior Staff Scientist Environmental Group Manager

Building Environmental Sciences

Ryan Slanczka Clark Grisell

Facilities | Environmental | Geotechnical | Materials iv

Table Of Contents

1.0 Introduction 1

1.1 Reliance 1

2.0 Building Description 1

3.0 Asbestos-Containing Materials Survey 1

3.1 Visual Assessment 2

3.2 Physical Assessment 2

3.3 Sample Collection 2

3.4 Sample Analysis 2

3.5 Regulatory Overview 3

3.6 Findings 3

4.0 General Comments 5

Appendices

Appendix A Asbestos-Containing Materials By Homogeneous Area

Appendix B Asbestos Survey Sample Location Summary

Appendix C Asbestos Laboratory Analytical Results

Appendix D Certifications

Facilities | Environmental | Geotechnical | Materials 1

1.0 Introduction

Terracon Consultants, Inc. (Terracon) conducted an asbestos-containing material survey of the Townsquare Shopping Center - Building 7 located at 128-140 South Clairborne

Road in Olathe, Kansas, on May 15, 2025. Building areas were visually assessed for suspect asbestos-containing materials (ACM). A reasonable effort was made to inspect accessible areas. Additional suspect materials could be present in walls, voids, or other concealed areas.

1.1 Reliance

This report is for the exclusive use of the City of Olathe, Kansas, for the project being discussed. Reliance by any other party on this report is prohibited without the written authorization of Terracon and the City of Olathe, Kansas.

2.0 Building Description

The subject building is an approximately 45,350-square-foot, single-story community shopping center (with exterior metal canopy), reportedly constructed in 1975. Interior flooring finishes include ceramic tiles, epoxy, sheet vinyl, carpeting, and vinyl tiles over concrete. Interior walls throughout the building are drywall/joint compound wallboard, with acoustic texture, wallpaper, and ceramic tile finishes in various areas. Perimeter walls throughout the building are concrete block and concrete block with an associated wall texture. The primary, observable ceiling system is a drop, grid ceiling with lay-in acoustic tiles below a metal deck. The building’s exterior has concrete block and fluted-block siding. The roof consists of a single-ply synthetic rubber membrane system.

3.0 Asbestos-Containing Materials Survey

The survey was conducted by Mr. Ryan Slanczka and Mr. Blake Harris, State of Kansas-accredited asbestos inspectors. Copies of the asbestos inspectors’ accreditations are attached as Appendix D. The survey was conducted in general accordance with the sample collection protocols established in the United States Environmental Protection

Agency (USEPA) 40 Code of Federal Regulations (CFR) Part 763 Subpart E 763.86, the

Asbestos Hazard Emergency Response Act (AHERA). A summary of survey activities is provided below.

Facilities | Environmental | Geotechnical | Materials 2

3.1 Visual Assessment

Survey activities were initiated with visual observation of the interior and exterior of the building to identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of a building material that appears similar throughout in terms of color and texture, with consideration given to the date of application. The assessment was conducted in visually accessible areas of the building scheduled for renovation.

3.2 Physical Assessment

A physical assessment of each HA of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material that can be crumbled, pulverized, or reduced to powder by hand pressure when dry.

Friability was assessed by physically touching suspect materials.

3.3 Sample Collection

Based on the results of the visual observation, bulk samples of suspect ACM samples were collected in general accordance with USEPA AHERA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each homogeneous area. Bulk samples were collected using wet methods, as applicable, to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

Rubber, wood products, plastic products, glass, and steel are not considered suspect

ACM and were, therefore, not sampled. The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content. Terracon collected 160 bulk samples from 51 homogeneous areas of suspect ACM.

3.4 Sample Analysis

Bulk samples were submitted under chain of custody to Eurofins International Asbestos

Testing Laboratories (Eurofins) of Mount Laurel, New Jersey, for analysis by PLM with dispersion staining techniques per USEPA Method 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. Eurofins is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), Accreditation No. 101165.

Facilities | Environmental | Geotechnical | Materials 3

3.5 Regulatory Overview

The asbestos National Emission Standards for Hazardous Air Pollutants (NESHAP) regulation (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

The asbestos NESHAP regulation classifies ACM as regulated asbestos-containing materials (RACM), Category I non-friable ACM, or Category II non-friable ACM. RACM includes all friable ACM; Category I non-friable ACM that has become friable or will be or has been subjected to sanding, grinding, cutting, or abrading; and Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder in the course of renovation or demolition activity. Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering mastics, and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. Category II non-friable ACM generally includes but is not limited to cementitious material such as cement pipes, cement siding, cement panels, glazing, mortar, and grouts.

The Kansas Department of Health and Environment’s (KDHE) Asbestos Control Section within the Bureau of Air enforces the Asbestos NESHAP as adopted by reference at

Kansas Administrative Regulations (K.A.R.) 28-19-735. The owner or operator must provide KDHE with written notification at least 10 working days prior to the commencement of asbestos abatement activities that will disturb RACM in amounts greater than or equal to 10 square feet or 25 linear feet.

The United States Occupational Safety and Health Administration (USOSHA) asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard classifies construction and maintenance activities that could disturb ACM and specifies work practices and precautions that employers must follow when engaging in each class of regulated work. The standard also specifies requirements for handling materials containing asbestos in concentrations less than or equal to one percent.

3.6 Findings

Asbestos was identified at a concentration greater than 1% in samples collected from the following materials:

Facilities | Environmental | Geotechnical | Materials 4

Material Description Material Location

NESHAP

Category

Estimated

Quantity

Black Mastic associated with 6" x 6" Red Ceramic Floor Tile with Grout and Mortar

Unit 134B - NW-Central Room, SW Room

Category I Nonfriable

Square Feet

12" x 12" Beige with Tan Streaks Floor Tile and Black Mastic

Unit 140 - Salesfloor, South Breakroom, SE Office

Category I Nonfriable

18,675 Square Feet

Black/Brown Mastic associated with 12" x 12" Beige Mottle Floor Tile with Tan & Brown Mastic

Unit 140 - Salesfloor, Women’s Restroom

Category I Nonfriable

Included in

Quantity of HA

Black Mastic associated with 12" x 12" Red Floor Tile

Unit 140 - Salesfloor Category I Nonfriable

Included in Quantity of HA

12" x 12" Grey with Tan Streaks Floor Tile and Black Mastic

Unit 132 - Restroom Category I Nonfriable

Square Feet

12" x 12" Tan/Green Design-Print

Floor Tile with Tan Mastic Unit 134A - North Room

Category I

Nonfriable

Square Feet

Faux-CFT Sheet Flooring with Paper Backing

Unit 130B - Restrooms RACM

Square Feet

Black Mastic associated with Grey/Light Grey/Blue with Black and White Flecks Epoxy Flooring

Unit 132 - NE-Central Area, West-Central Area, SE Area

Category I Nonfriable

Square Feet

Black Wall Mastic Unit 140 - South Breakroom, West Wall

Category I

Nonfriable

Linear Feet

Roofing Material Roof - On East AHU over

Unit 128 Category I Nonfriable

Linear Feet

Flashing Sealant

Roof - NE Corner Breezeway

Wall, East Perimeter Wall over Unit 128, South-Central Area Exhaust over Unit 140

Category I Nonfriable

Linear Feet

Tar Sealant Roof - On Pipes over Units

138 and 140 Category I Nonfriable

Linear Feet

Notes: NESHAP - National Emission Standards for Hazardous Air Pollutants RACM - Regulated Asbestos-Containing Material

The above-listed RACM must be removed by a State of Kansas licensed abatement contractor prior to any activities (renovation and/or demolition) that may disturb the material in accordance with applicable federal, state, and local regulations.

The above-listed Category I non-friable ACM that is damaged or could be damaged to the extent that it could be crumbled, pulverized, or reduced to powder when dry, making it friable, must be removed prior to any activities (renovation and/or demolition) that may disturb this material in accordance with applicable federal, state, and local

Facilities | Environmental | Geotechnical | Materials 5 regulations. Terracon recommends that all ACM be removed by an abatement contractor prior to any demolition or renovation work that may disturb it.

Asbestos was identified at a concentration of 1% or less in samples collected from the following materials:

Material Description Material Location

Joint Compound associated with Drywall Wallboard

System Throughout Subject Building

12" x 12" Red Floor Tile Unit 140 - Salesfloor

Materials containing 1% or less asbestos are not regulated by NESHAP or AHERA;

however, the USOSHA personal exposure limits (0.1 f/cc of air as an eight-hour time-weighted average or 1.0 f/cc of air over 30 minutes) for asbestos apply when materials containing 1% asbestos or less are disturbed during renovations or demolitions. A listing of materials that contain 1% asbestos or less is provided above to enable the renovation/demolition contractor to make appropriate decisions concerning compliance issues with applicable USOSHA regulations.

Joint Compound and/or tape that is applied to a wallboard system becomes an integral part of that wallboard system. A composite analysis of the wall system (percent of asbestos in the joint compound, tape, and wallboard composite) should be conducted where a demolition or renovation is to be performed, and when allowed by regulations

(not allowed in some states). This is in addition to analysis by layers. State and local agencies should be consulted for additional regulatory requirements.

A summary of identified asbestos-containing materials by homogeneous area is included in Appendix A. A summary of sample locations is included in Appendix B. Laboratory analytical reports are included in Appendix C.

4.0 General Comments

Terracon did not perform sampling that required demolition or destructive activities such as dismantling of equipment or removal of protective coverings. Reasonable efforts to access suspect materials within known areas of restricted access (e.g., crawl spaces) were made; however, confined spaces or areas that may pose a health or safety risk to

Terracon personnel were not sampled. Sampling did not include suspect materials that could not be safely reached with available ladders or manlifts. Terracon did not sample suspect materials that may be present in movable equipment such as freezers, kitchen equipment, and hoods. Terracon typically investigates for flooring beneath carpeting by

Facilities | Environmental | Geotechnical | Materials 6 lifting small corner sections of carpet. If tiles or sheet vinyl were seen, they have been identified in the report. If tiles or sheet vinyl were not seen at corners under the carpet, it does not imply that there is none beneath the carpeted floor. Terracon did not conduct a destructive investigation of the doors in the building to determine if the doors were insulated for fire-rating purposes.

This survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during Terracon’s survey of the building. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by the City of Olathe, Kansas, and is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in the preparation of this report. No warranty, express or implied, is made.

Appendix A

Asbestos-Containing Materials By Homogeneous Area

Appendix A-1

Identified Asbestos-Containing Materials By Homogeneous Area (HA)

128-140 South Clairborne Road, Olathe, Kansas

Terracon Project No. 02237230

HA Material Description Material Location % and Type

Asbestos*

NESHAP

Classification Condition

Estimated

Quantity**

Black Mastic associated with 6" x 6" Red Ceramic Floor Tile with Grout and Mortar

Unit 134B - NW-Central Room, SW Room

Red Ceramic Tile - None Detected

Black Mastic - 2% Chrysotile Grey Grout - None Detected

Off-White Mortar - None Detected

Light Grey Mortar - None Detected

Category I Nonfriable

Damaged (Fair)

Square Feet

12" x 12" Beige with Tan

Streaks Floor Tile and Black Mastic

Unit 140 - Salesfloor, South Breakroom, SE Office

White Floor Tile - 2% Chrysotile

Beige Floor Tile - 2% Chrysotile Black Mastic - 2% Chrysotile

Category I Nonfriable

Damaged (Fair)

18,675 Square Feet

Black/Brown Mastic associated with 12" x 12"

Beige Mottle Floor Tile with Tan & Brown Mastic

Unit 140 - Salesfloor, Women’s Restroom

Beige Floor Tile - None Detected

Brown Mastic - None Detected Black/Brown Mastic - 2%

Chrysotile

Category I Nonfriable

Damaged (Fair)

Included in Quantity of HA

24 Black Mastic associated with 12" x 12" Red Floor Tile

Unit 140 - Salesfloor Red Floor Tile - <1% Chrysotile

Black Mastic - 3% Chrysotile Category I Nonfriable

Damaged (Fair)

Included in Quantity of HA

12" x 12" Grey with Tan

Streaks Floor Tile and Black Mastic

Unit 132 - Restroom

Tan Floor Tile with Grey Paint - 2% Chrysotile

Tan Floor Tile - 2% Chrysotile Black Mastic - 2% Chrysotile

Category I Nonfriable

Damaged (Fair)

Square Feet

12" x 12" Tan/Green

Design-Print Floor Tile with Tan Mastic

Unit 134A - North Room

Tan Floor Tile - 2% Chrysotile Green Floor Tile - 2%

Chrysotile Tan Mastic - None Detected

Beige Mastic - None Detected

Category I Nonfriable

Damaged (Fair)

Square Feet

Faux-CFT Sheet Flooring with Paper Backing Unit 130B - Restrooms

Tan Sheet Flooring - 25% Chrysotile

Yellow Mastic - None Detected

RACM

Damaged (Fair)

Square Feet

Asbestos*

NESHAP

Classification Condition

Estimated

Quantity**

Black Mastic associated with Grey/Light Grey/Blue with

Black and White Flecks Epoxy Flooring

Unit 132 - NE-Central Area, West-Central Area, SE Area

Grey Flooring Epoxy - None Detected

Black Mastic - 2% Chrysotile

Category I Nonfriable

Damaged (Fair)

Square Feet

48 Black Wall Mastic Unit 140 - South

Breakroom, West Wall Black Mastic - 3% Chrysotile

Category I Nonfriable

Good

Linear Feet

63 Roofing Material Roof - On East AHU over

Unit 128 Black Roofing Material - 20%

Chrysotile Category I Nonfriable

Good

Linear Feet

65 Flashing Sealant

Roof - NE Corner Breezeway Wall, East Perimeter Wall over Unit 128, South- Central Area Exhaust over

Unit 140

White Sealant - None Detected Grey Sealant - None Detected

Black Tar - 8% Chrysotile

Category I Nonfriable

Good

Linear Feet

66 Tar Sealant Roof - On Pipes over Units

138 and 140 Black/White Tar - 7%

Chrysotile Category I Nonfriable

Good

Linear Feet

*% & Type Asbestos – this column contains both the analytical result of the sample with the highest concentration of asbestos detected in the samples that make up the HA, and the types of asbestos identified.

**Estimated quantities – quantities based on a cursory field evaluation, and actual quantities may vary significantly, especially if asbestos-containing materials are present in hidden and/or inaccessible areas not evaluated as part of this survey. This is not a bidding document; contractors are responsible for determining their own opinion of quantities.

Appendix A-2

Materials Containing Asbestos at a Concentration of 1% or Less By HA

Asbestos* Condition

Joint Compound associated with Drywall

Wallboard System Throughout Subject Building

White Drywall with Brown Paper - None Detected White Joint Compound - 2% Chrysotile

Beige Tape - None Detected Sample Composite - <1% Chrysotile

Damaged (Fair)

24 12" x 12" Red Floor Tile Unit 140 - Salesfloor Red Floor Tile - <1% Chrysotile Damaged

(Fair)

*% & Type Asbestos – this column contains both the analytical result of the sample with the highest concentration of asbestos detected in the samples that make up the HA, and the types of asbestos identified.

<1% - Materials containing less than 1% asbestos are not regulated by NESHAP or AHERA; however, the USOSHA personal exposure limits (0.1 f/cc of air as an eight-hour time-weighted average or 1.0 f/cc of air over 30 minutes) for asbestos apply when materials containing 1% asbestos or less are disturbed during renovation or demolition. A listing of materials that contain 1% asbestos or less is provided above to enable the renovation/demolition contractor to make appropriate decisions concerning compliance issues with applicable USOSHA regulations.

Appendix B

Asbestos Survey Sample Location Summary

Appendix B

Asbestos Survey Sample Location Summary

HA

No.

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

Drywall with Joint

Compound

01-WB5-01 Unit 140 - Salesfloor, SW Area, East Wall

White Drywall with Brown Paper

None Detected

White Joint Compound

01-WB5-02 Unit 140 - Stockroom, North Wall

White Drywall with Brown Paper

None Detected

White Joint Compound

01-WB5-03 Unit 140 - Salesfloor, SW Area, West Wall

White Drywall with Brown Paper None Detected

White Joint Compound 2% Chrysotile

Beige Tape None Detected

Composite <1% Chrysotile

01-WB5-04 Unit 138 - East Wall

White Drywall with Brown Paper

None Detected White Joint Compound

Beige Tape

01-WB5-05 Unit 132 - West Wall, Central Area

White Drywall with Brown Paper

None Detected White Joint Compound

Beige Tape

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

Drywall with Joint

Compound

01-WB5-06

Unit 134B - North Room, West Wall, North

Area

White Drywall with Brown Paper

None Detected White Joint Compound

Beige Tape

01-WB5-07

Unit 130B - North Room, South Wall, near door to NE Room

White Drywall with Brown Paper

None Detected

White Joint Compound

2 Orange-Peel Wall Texture

02-PL1-08 Unit 134A - Hallway, West Wall, North Area White Texture

None Detected 02-PL1-09 Unit 134A - Hallway, West Wall, Central Area White Texture

02-PL1-10 Unit 134A - Hallway, West Wall, South Area White Texture

3 Plaster Wall Texture

03-PL1-11 Unit 132 - Restroom, North Wall White Texture

None Detected 03-PL1-12 Unit 132 - Restroom, East Wall White Texture

03-PL1-13 Unit 132 - Restroom, East Wall White Texture

4 Plaster Wall Texture

04-PL1-14

Unit 130B - WNW Room, West Wall, North

Area White Texture

None Detected 04-PL1-15 Unit 130B - WNW Room, West Wall, Central

Area White Texture

04-PL1-16

Unit 130B - WNW Room, West Wall, South

Area White Texture

5 Wallpaper

05-SG5-17 Unit 134A - North Room, North Area, East Wall Blue Wallpaper

None Detected 05-SG5-18 Unit 134A - North Room, North Area, East Wall Blue Wallpaper

05-SG5-19 Unit 134A - North Room, North Area, East Wall Blue Wallpaper

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

6 Concrete Wall Texture

06-SC5-20 Unit 140 - South Perimeter Wall White Concrete Wall Texture

None Detected

06-SC5-21 Unit 140 - South Perimeter Wall White Concrete Wall Texture

06-SC5-22 Unit 140 - East Perimeter Wall White Concrete Wall Texture

06-SC5-23 Unit 138 - South Perimeter Wall Tan Concrete Wall Texture

06-SC5-24 Unit 132 - South Perimeter Wall, Central Area Tan Concrete Wall Texture

06-SC5-25 Unit 128 - Exterior, East

Tan Concrete Wall Texture

Grey Concrete

06-SC5-26 Unit 140 - Exterior, SE Corner

Tan Concrete Wall Texture

Grey Concrete

2' x 4' Ceiling Tile with

Pinholes and Divots

07-CT4-27 Unit 134A - South Room, South Area White Ceiling Tile

None Detected 07-CT4-28 Unit 140 - South Breakroom White Ceiling Tile

07-CT4-29 Unit 134B - North Room, West Area White Ceiling Tile

2' x 4' Fiberglass Ceiling

Tile with Pinholes and

Fissures

08-CT4-30 Unit 132 - NW Area Yellow/White Ceiling Tile

None Detected 08-CT4-31 Unit 140 - South Breakroom Yellow/White Ceiling Tile

08-CT4-32 Unit 140 - Women's Restroom Yellow/White Ceiling Tile

2' x 4' Ceiling Tile with

Pinholes and Fissures

09-CT4-33 Unit 140 - Women's Restroom White Ceiling Tile

None Detected 09-CT4-34 Unit 134B - Central Room, Central Area White Ceiling Tile

09-CT4-35 Unit 132 - NW Area White Ceiling Tile

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

2' x 4' Ceiling Tile with

High-Density Pinholes and

Fissures

10-CT4-36 Unit 134A - North Room, South Area White Ceiling Tile

None Detected 10-CT4-37 Unit 130B - WNW Room, South Area White Ceiling Tile

10-CT4-38 Unit 134A - South Room, East Area White Ceiling Tile

2' x 4' Ceiling Tile with

Pinholes and Dents

11-CT4-39 Unit 134B - North Room, North Area White Ceiling Tile

None Detected 11-CT4-40 Unit 134A - South Room, South Area White Ceiling Tile

11-CT4-41 Unit 132 - West-Central Area White Ceiling Tile

2' x 2' Rough-Textured

Ceiling Tile with Pinholes

12-CT4-42 Unit 134A - East-Central Room, North Area White Ceiling Tile

None Detected 12-CT4-43 Unit 134A - East-Central Room, South Area White Ceiling Tile

12-CT4-44 Unit 134A - SE-Central Room, West Area White Ceiling Tile

13 2' x 4' Gypsum Ceiling Tile

13-CT4-45 Unit 134B - North Room, West Area White Ceiling Tile (Gypsum)

None Detected 13-CT4-46 Unit 134B - SW Room, Central Area White Ceiling Tile (Gypsum)

13-CT4-47 Unit 134B - SW-Central Room, NE Area White Ceiling Tile (Gypsum)

4" Cove Base with Tan and

Brown Mastic

14-FC3-48 Unit 140 - Salesfloor, North Wall

Brown Cove Base

None Detected

Tan Mastic

Brown Mastic

14-FC3-49 Unit 140 - SE Office

White Cove Base

Tan Mastic

Brown Mastic

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

4" Cove Base with Tan and

Brown Mastic 14-FC3-50 Unit 140 - SE Office

Brown Cove Base

None Detected Tan Mastic

Brown Mastic

4" Cove Base with Tan

Mastic

15-FC3-51 Unit 136 - North Area, East Wall

White/Grey Cove Base

None Detected

Tan Mastic

15-FC3-52

Unit 134B - North Room, East Wall, South

Area

Black Cove Base

Tan Mastic

15-FC3-53

Unit 130B - North Room, West Wall, North

Area

Grey Cove Base

Tan Mastic

4" Cove Base with Brown

Mastic

16-FC3-54 Unit 132 - SW Room, West Wall

Brown Cove Base

None Detected

Brown Mastic

16-FC3-55

Unit 134B - North Room, West Wall, Central

Area

Black Cove Base

Brown Mastic

16-FC3-56

Unit 134B - North Room, West Wall, Central

Area

Black Cove Base

Brown Mastic

6" x 6" Red Ceramic Wall

Tile with Grout and Mastic

17-MA5-57

Unit 134B - North Room, West Wall, Central

Area

Red Ceramic Tile

None Detected Yellow Mastic

Grey Grout

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

6" x 6" Red Ceramic Wall

Tile with Grout and Mastic

17-MA5-58

Unit 134B - North Room, West Wall, Central

Area

Red Ceramic Tile

None Detected

Yellow Mastic

Grey Grout

17-MA5-59

Unit 134B - South-Central Room, North Wall, near Door

Red Ceramic Tile

Yellow Mastic

Grey Grout

6" x 6" Red Ceramic Wall

Tile with Grout and Mortar

18-MA5-60 Unit 134B - WNW Room, West Wall

Red Ceramic Tile

None Detected

Grey Grout

18-MA5-61 Unit 134B - SW Room, West Wall, Central Area

Red Ceramic Tile

Yellow Mastic

Grey Grout

18-MA5-62 Unit 134B - SW Room, West Wall, South Area

Red Ceramic Tile

Yellow Mastic

Grey Grout

Grey/Red Ceramic Floor

Tile with Grout and Mortar 19-MA5-63 Unit 136 - SW Room

Red Ceramic Tile

None Detected

Yellow Mastic

Grey Grout

White Mortar

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

Grey/Red Ceramic Floor

Tile with Grout and Mortar

19-MA5-64 Unit 136 - SW Room

Red Ceramic Tile

None Detected

White Mortar

Grey Grout

19-MA5-65 Unit 136 - SW Room

Red Ceramic Tile

White Mortar

Grey Grout

6" x 6" Red Ceramic

Floor Tile with Grout and Mortar

20-MA5-66 Unit 134B - NW-Central Room

Red Ceramic Tile None Detected

Black Mastic 2% Chrysotile

Grey Grout None Detected

Off-White Mortar None Detected

20-MA5-67 Unit 134B - SW Room, NE Area

Red Ceramic Tile None Detected

Grey Grout None Detected

Light Grey Mortar None Detected

Black Mastic 2% Chrysotile

20-MA5-68 Unit 134B - SW Room, NE Area

Red Ceramic Tile None Detected

Grey Grout None Detected

Light Grey Mortar None Detected

Black Mastic 2% Chrysotile

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

12" x 12" Tan Ceramic

Floor Tile with Grout and

Mortar

21-MA5-69 Unit 130B - NE Room

Brown Ceramic Tile

None Detected

Grey Grout

Brown Mortar

21-MA5-70 Unit 130B - NE Room

Brown Ceramic Tile

Grey Grout

Brown Mortar

21-MA5-71 Unit 130B - NE Room

Brown Ceramic Tile

Grey Grout

Brown Mortar

12" x 12" Beige with

Tan Streaks Floor Tile with Black Mastic

22-FT2-72 Unit 140 - Salesfloor, NW Area

White Floor Tile 2% Chrysotile

Black Mastic 2% Chrysotile

22-FT2-73 Unit 140 - South Breakroom

Beige Floor Tile 2% Chrysotile

Black Mastic 2% Chrysotile

22-FT2-74 Unit 140 - SE Office

Beige Floor Tile 2% Chrysotile

Black Mastic 2% Chrysotile

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

12" x 12" Beige Mottle

Floor Tile with Tan &

Brown Mastic

23-FT2-75 Unit 140 - Salesfloor, Central Area

Beige Floor Tile

None Detected

Brown Mastic

23-FT2-76 Unit 140 - Women's Restroom

Beige Floor Tile None Detected

Black/Brown Mastic 2% Chrysotile

23-FT2-77 Unit 140 - Salesfloor, SW Area

Beige Floor Tile None Detected

Black/Brown Mastic 2% Chrysotile

12" x 12" Red Floor Tile with Black Mastic

24-FT2-78 Unit 140 - Salesfloor, West Area

Red Floor Tile < 1%

Chrysotile

Black Mastic 3% Chrysotile

24-FT2-79 Unit 140 - Salesfloor, West Area

Red Floor Tile < 1%

Chrysotile

Black Mastic 3% Chrysotile

24-FT2-80 Unit 140 - Salesfloor, West Area

Red Floor Tile < 1%

Chrysotile

Black Mastic 3% Chrysotile

12" x 12" Grey Mottle Floor

Tile with Tan Mastic

25-FT2-81 Unit 138 - SE Restroom

Grey Floor Tile

None Detected

Tan Mastic

25-FT2-82 Unit 138 - SE Restroom

Grey Floor Tile

Tan Mastic

White Joint Compound

25-FT2-83 Unit 138 - SE Restroom

Grey Floor Tile

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

12" x 12" White Mottle

Floor Tile with Tan Mastic

26-FT2-84 Unit 136 - NW Area

White Floor Tile with Black Paint

None Detected

Tan Mastic

26-FT2-85 Unit 136 - South Area

White Floor Tile with Black Paint

Tan Mastic

26-FT2-86 Unit 136 - SE Room

White Floor Tile

Tan Mastic

26-FT2-87 Unit 136 - NE Area

White Floor Tile with Black Paint

Tan Mastic

12" x 12" Grey with Tan

Streaks Floor Tile with

Black Mastic

27-FT2-88 Unit 132 - Restroom

Tan Floor Tile with Grey Paint 2% Chrysotile

Black Mastic 2% Chrysotile

27-FT2-89 Unit 132 - Restroom

Tan Floor Tile with Grey Paint 2% Chrysotile

Black Mastic 2% Chrysotile

27-FT2-90 Unit 132 - Restroom

Tan Floor Tile 2% Chrysotile

Black Mastic 2% Chrysotile

12" x 12" Light Grey with

Black Streaks Floor Tile with Tan Mastic

28-FT2-91 Unit 134A - North Room, North Area

Grey Floor Tile

None Detected

Tan Mastic

28-FT2-92 Unit 134A - North Room, North Area

Grey Floor Tile

Tan Mastic

28-FT2-93 Unit 134A - North Room, North Area

Grey Floor Tile

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

12" x 12" Tan/Green

Design-Print Floor Tile with Tan Mastic

29-FT2-94 Unit 134A - North Room, North Area

Tan Floor Tile 2% Chrysotile

Tan Mastic None Detected

Beige Mastic None Detected

29-FT2-95 Unit 134A - North Room, Central Area

Tan Floor Tile 2% Chrysotile

Tan Mastic None Detected

Beige Mastic None Detected

29-FT2-96 Unit 134A - North Room, Central Area

Green Floor Tile 2% Chrysotile

Tan Mastic None Detected

Beige Mastic None Detected

Peel 'n' Stick Floor Tile with

Adhesive

30-FT2-97 Unit 134B - North Room, NE Area

Grey Floor Tile Peel and Stick

None Detected

Tan Mastic

30-FT2-98 Unit 134B - SW Room, NE Area

Grey Floor Tile Peel and Stick

Tan Mastic

30-FT2-99 Unit 134B - North Room, West-Central Area

Grey Floor Tile Peel and Stick

Tan Mastic

12" x 12" Green, Tan Floor

Tile with Tan Mastic

31-FT2-100 Unit 134B - North Room, NE Area

Tan Floor Tile

None Detected

Tan Mastic

31-FT2-101 Unit 134B - North Room, SE-Central Area

Tan Floor Tile

Grey Leveling Compound

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

12" x 12" Green, Tan Floor

Tile with Tan Mastic 31-FT2-102 Unit 134B - North Room, West-Central Area

Green Floor Tile

None Detected

Tan Mastic

6" x 6" Green, Red Floor

Tile with Tan Mastic

32-FT2-103

Unit 134B - South Hallway, near North

Restroom

Red Floor Tile

None Detected

Tan Mastic

32-FT2-104

Unit 134B - South Hallway, near North

Restroom

Green Floor Tile

Tan Mastic

32-FT2-105

Unit 134B - South Hallway, near North

Restroom

Red Floor Tile

Tan Mastic

12" x 12" Tan Floor Tile with Mastic

33-FT2-106 Unit 128 - NE Room, near Door

Tan Floor Tile

None Detected

Black Mastic

33-FT2-107 Unit 128 - Kitchen, NE Area

Tan Floor Tile

Tan Mastic

33-FT2-108 Unit 130A - West Restroom

Tan Floor Tile

Tan Mastic

Faux-CFT Sheet Flooring with Paper Backing

34-FC1-109 Unit 130B - West Restroom Tan Sheet Flooring 25% Chrysotile

34-FC1-110 Unit 130B - West Restroom Tan Sheet Flooring 25% Chrysotile

34-FC1-111 Unit 130B - South Restroom

Tan Sheet Flooring 25% Chrysotile

Yellow Mastic None Detected

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

35 Tan Carpet Adhesive

35-MG7-112 Unit 136 - South Area Yellow Mastic with Grey Fibrous

Material

None Detected 35-MG7-113 Unit 136 - South Area Yellow Mastic with Grey Fibrous

Material

35-MG7-114 Unit 136 - South Area Yellow Mastic

36 Tan Carpet Adhesive

36-MG7-115 Unit 134A - North Room, North Area Yellow Mastic

None Detected 36-MG7-116 Unit 134A - North Room, North Area Yellow Mastic

36-MG7-117 Unit 134A - North Room, North Area Yellow Mastic

Tan Carpet Adhesive with

Paper

37-MG7-118 Unit 134A - Hallway, Central Area

Red Carpet

None Detected

Yellow Mastic

Brown Insulation

Brown Paper

37-MG7-119 Unit 134A - Hallway, Central Area

Red Carpet

Yellow Mastic

Brown Insulation

Brown Paper

37-MG7-120 Unit 134A - Hallway, Central Area

Red Carpet

Yellow Mastic

Brown Insulation

Brown Paper

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

38 Tan Carpet Adhesive

38-MG7-121 Unit 134B - North Room, SE Area Yellow Mastic

None Detected 38-MG7-122 Unit 134B - SE Room, East-Central Area Yellow Mastic

38-MG7-123 Unit 134B - North Room, NE Area Yellow Mastic

39 Tan Carpet Adhesive

39-MG7-124 Unit 130B - North Room, Central Area Yellow Mastic

None Detected 39-MG7-125 Unit 130B - WNW Room, Central Area Yellow Mastic

39-MG7-126 Unit 130B - SE Room Yellow Mastic

40 Residual Black Mastic

40-MG5-127

Unit 128 - North Room, near NE Overhead

Door Black Mastic

None Detected 40-MG5-128 Unit 128 - North Room, Central Area Black Mastic

40-MG5-129 Unit 130A - South Area Black Mastic

Grey/Light Grey/Blue with Black and White

Flecks Epoxy Flooring

41-FC2-130 Unit 132 - NE-Central Area Grey Flooring Epoxy None Detected

41-FC2-131 Unit 132 - West-Central Area

Grey Flooring Epoxy None Detected

Black Mastic 2% Chrysotile

41-FC2-132 Unit 132 - SE Area

Grey Flooring Epoxy None Detected

Black Mastic 2% Chrysotile

42 Epoxy Flooring

42-FC2-133 Unit 134B - North Restroom Grey/White Flooring Epoxy

None Detected 42-FC2-134 Unit 134B - South Restroom Grey/White Flooring Epoxy

42-FC2-135 Unit 134B - South Restroom Grey/White Flooring Epoxy

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

Pink, Grey Leveling

Compound

43-FC6-136 Unit 134B - North Room, NW Area Pink/Grey Leveling Compound

None Detected

43-FC6-137 Unit 134B - North Room, SE-Central Area Pink/Grey Leveling Compound

43-FC6-138 Unit 134B - North Room, SW Area Pink/Grey Leveling Compound

43-FC6-139 Unit 134B - North Room, West-Central Area Pink/Grey Leveling Compound

43-FC6-140 Unit 134B - North Room, West-Central Area Pink/Grey Leveling Compound

44 White Leveling Compound

44-FC6-141 Unit 134B - North Room, NE-Central Area

White Leveling Compound

None Detected

Yellow Mastic

44-FC6-142 Unit 134B - North Room, NE-Central Area

White Leveling Compound

Yellow Mastic

44-FC6-143 Unit 134B - North Room, NE Area

White Leveling Compound

Yellow Mastic

Pink-White Leveling

Compound

45-FC6-144 Unit 134B - SW Room, NW Area

White Leveling Compound

None Detected

Yellow Mastic

45-FC6-145 Unit 134B - SW Room, NW Area

White Leveling Compound

Yellow Mastic

45-FC6-146 Unit 134B - SW Room, NW Area

White Leveling Compound

Yellow Mastic

46 Concrete Slab

46-CP5-147 Unit 140 - Stockroom, East Area Grey Concrete

None Detected

46-CP5-148 Unit 138 - Open Room, Central Area Grey Concrete

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

46 Concrete Slab 46-CP5-149 Unit 132 - NW Area, at Door to Unit 134A Grey Concrete None Detected

47 Door Caulk

47-CA2-150 Unit 130B - Door to South Exterior

White Caulk

None Detected

Tan Cementitious Material

47-CA2-151 Unit 130B - Door to South Exterior

White Caulk

Tan Cementitious Material

47-CA2-152 Unit 130B - Door to South Exterior

White Caulk

Tan Cementitious Material

48 Black Wall Mastic

48-MG5-153 Unit 140 - South Breakroom, West Wall Black Mastic 3% Chrysotile

48-MG5-154 Unit 140 - South Breakroom, West Wall Black Mastic 3% Chrysotile

48-MG5-155 Unit 140 - South Breakroom, West Wall Black Mastic 3% Chrysotile

49 Grey/Green Wall Mastic

49-MG5-156 Unit 140 - Salesfloor, SW Area, East Wall Grey Mastic

None Detected 49-MG5-157 Unit 140 - Salesfloor, SW Area, East Wall Grey Mastic

49-MG5-158 Unit 140 - Salesfloor, SW Area, East Wall Grey Mastic

50 Black Wall Mastic

50-MG5-159 Unit 140 - Salesfloor, SW Area, East Wall

Black Mastic

None Detected

Yellow Mastic

50-MG5-160 Unit 140 - Salesfloor, SW Area, East Wall

Black Mastic

Yellow Mastic

50-MG5-161 Unit 140 - Salesfloor, SW Area, East Wall

Black Mastic

Yellow Mastic

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

51 Brown Drywall Mastic

51-MG5-162 Unit 132 - West Wall, South Area Brown Mastic

None Detected 51-MG5-163 Unit 132 - West Wall, South Area Brown Mastic

51-MG5-164 Unit 132 - West Wall, South Area Brown Mastic

52 Dark Tan FRP Mastic

52-MG5-165 Unit 138 - SE Restroom Tan Mastic

None Detected 52-MG5-166 Unit 138 - SE Restroom Tan Mastic

52-MG5-167 Unit 138 - SE Restroom Tan Mastic

53 Dark Tan FRP Mastic

53-MG5-168

Unit 134B - North Room, East Wall, South

Area Tan Mastic

None Detected 53-MG5-169 Unit 134B - North Room, North Wall, West

Area Tan Mastic

53-MG5-170 Unit 134B - North Room, East Wall, North Area Tan Mastic

1" x 1" Faux-Stone

Ceramic Table-Top Tile with Grout and Adhesive

54-MA5-171 Unit 132 - SE Area, Table-Top, West Side

Grey Ceramic Tile

None Detected

White Mortar

Grey Mortar

54-MA5-172 Unit 132 - SE Area, Table-Top, South End

Grey Ceramic Tile

White Mortar

Grey Mortar

54-MA5-173 Unit 132 - SE Area, Table-Top, East Side

Grey Ceramic Tile

Grey Mortar

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

55 Fiberglass Pipe Insulation

55-PI4-174 Unit 130A - South Area, near Water Heater

Yellow Insulation

None Detected

Silver/Beige Wrap

55-PI4-175 Unit 130A - South Area, near Water Heater

Yellow Insulation

Silver/Beige Wrap

55-PI4-176 Unit 130A - Restroom

Yellow Insulation

Silver/Beige Wrap

56 Fluted-Stone Siding Mortar

56-MA3-177 Unit 128 - East Exterior, Siding Light Brown Mortar

None Detected 56-MA3-178 Unit 140 - West Exterior, Siding Light Brown Mortar

56-MA3-179 Unit 134A - North Exterior, Column Grey Mortar

57 Concrete Block Mortar

57-MA2-180 Unit 134A - North Perimeter Wall, near Door Light Brown Mortar

None Detected 57-MA2-181 Unit 134B - North Perimeter Wall, near West

Door Light Brown Mortar

57-MA2-182 Unit 128 - North Perimeter Wall, near Door Light Brown Mortar

58 Concrete Block Mortar

58-MA2-183 Unit 140 - East Exterior Grey Mortar

None Detected 58-MA2-184 Unit 140 - SW Room, West Wall Light Brown Mortar

58-MA2-185 Unit 140 - Stockroom, East Wall Grey Mortar

Drywall with Joint

Compound

59-WB5-186 Unit 128 - North Exterior, Awning Soffit

White Drywall with Brown Paper

None Detected

White Joint Compound

59-WB5-187 Unit 134A - North Exterior, Awning Soffit

White Drywall with Brown Paper

White Joint Compound

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

Drywall with Joint

Compound 59-WB5-188 Unit 138 - North Exterior, Awning Soffit

White Drywall with Brown Paper

None Detected

White Joint Compound

Dark Brown Expansion

Joint

60-MS5-189 Unit 128 - NE Exterior Black Expansion Joint

None Detected 60-MS5-190 Unit 138 - North Exterior Black Expansion Joint

60-MS5-191 Unit 138 - North Exterior Black Expansion Joint

61 Black Expansion Joint

61-MS5-192 Unit 128 - East Exterior, at Loading Bay Door Black Expansion Joint Tar

None Detected 61-MS5-193 Unit 128 - East Exterior, at Loading Bay Door Black Expansion Joint Tar

61-MS5-194 Unit 128 - East Exterior, at Loading Bay Door Black Expansion Joint Tar

62 Stone Wall Finish

62-MA6-195 Unit 128 - East Exterior Light Brown Cementitious

Material

None Detected 62-MA6-196 Unit 140 - West Exterior Light Brown Cementitious

Material

62-MA6-197 Unit 140 - North Exterior Light Brown Cementitious

Material

63 Roofing Material

63-RF5-198

Roof - East Area, on East AHU, over Unit

Black Roofing Material 20% Chrysotile

63-RF5-199

Roof - East Area, on East AHU, over Unit

Black Roofing Material 15% Chrysotile

63-RF5-200

Roof - East Area, on East AHU, over Unit

Black Roofing Material 20% Chrysotile

64 Roofing Material 64-RF5-201 Roof - East Area, over Unit 128

White/Black Roofing Membrane

None Detected

Brown/Black Insulation

Yellow Insulation

Black/Silver Roofing Material

Black Roofing Material

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

64 Roofing Material

64-RF5-202 Roof - Central Area, over Unit 138

White/Black Roofing Membrane

None Detected

Brown/Black Insulation

Yellow Insulation

Black Roofing Material #1

Black Roofing Material #2

64-RF5-203 Roof - West Area, over Unit 140

White/Black Roofing Membrane

Yellow Insulation

Black Roofing Material #1

Black Roofing Material #2

Black Roofing Material #3

65 Flashing Sealant

65-RF1-204

Roof - NE Corner, Breezeway Wall, over

Unit 128

White Sealant None Detected

Black Tar 8% Chrysotile

65-RF1-205

Roof - East Perimeter Wall, South Area, over Unit 128

Grey Sealant None Detected

Black Tar 8% Chrysotile

65-RF1-206

Roof - Over Unit 140, South-Central Area, on Exhaust

White Sealant None Detected

Black Tar 7% Chrysotile

66 Tar Sealant

66-RF1-207

Roof - Over Unit 140, East-Central Area, on Pipe Black/White Tar 6% Chrysotile

66-RF1-208

Roof - SW-Central Area, on Pipe, over Unit

Black/White Tar 7% Chrysotile

66-RF1-209

Roof - Central Area, on Pipe, over Unit

Black/White Tar None Detected

Material Description

Sample

Number Sample Location Sample Layer Description Lab Results

67 Foamboard Paper

67-RF2-210 Roof - Along West Perimeter, over Unit 140 Grey Paper

None Detected 67-RF2-211 Roof - Along West Perimeter, over Unit 140 Grey Paper

67-RF2-212 Roof - Along West Perimeter, over Unit 140 Grey Paper

68 Asphaltic Shingle

68-RF3-213

Roof - Wall between Units 138 and 140, East

Side Brown/Black Roofing Shingle

None Detected 68-RF3-214 Roof - Wall between Units 138 and 140, East

Side Brown/Black Roofing Shingle

68-RF3-215

Roof - Wall between Units 138 and 140, East

Side Brown/Black Roofing Shingle

Asbestos-containing materials in BOLD.

Italics - Materials containing 1% or less asbestos

Appendix C

Asbestos Laboratory Analytical Results

Approved by:

Approved Signatory Frank Ehrenfeld

Report for:

Ryan Slanczka Terracon Consultants- Lenexa 15620 W. 113th St Lenexa, KS 66219

Regarding:

Eurofins Built Environment Testing East, LLC Project: 02237230.03.2 - 128-140 S Clairborne Rd

EML ID: 4128787

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins Built Environment Testing East, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM (Layer %): 07-08-2025

Service SOPs: Asbestos PLM (Layer %) (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EB-AS-S- 1267) NVLAP Lab Code 101165-0

EMLab ID: 4128787, Page 1 of 39Eurofins Built Environment Testing East, LLC

Eurofins Built Environment Testing East, LLC 9000 Commerce Parkway, Suite B, Mount Laurel, NJ 08054

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230.03.2 - 128-140 S Clairborne Rd

Date of Receipt: 06-30-2025 Date of Report: 07-08-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

01-WB5-01. Drywall with Joint Compound; Unit 140 - Salesfloor, SW Area, East Wall 20617326-1

Layer 1 White Drywall with Brown Paper Homogeneity:Good

Not Detected 85% Non-Fibrous Material 15% Cellulose

A

Layer 2

Homogeneity:Good

Not Detected 100% Non-Fibrous Material A

Composite Asbestos ND A

01-WB5-02. Drywall with Joint Compound; Unit 140 - Stockroom, North Wall 20617327-1

Layer 1 White Drywall with Brown Paper Homogeneity:Good

Not Detected 85% Non-Fibrous Material

Homogeneity:Good

Not Detected 100% Non-Fibrous Material A

Composite Asbestos ND A

01-WB5-03. Drywall with Joint Compound; Unit 140 - Salesfloor, SW Area, West Wall 20617328-1

Layer 1 White Drywall with Brown Paper Homogeneity:Good

Not Detected 85% Non-Fibrous Material

B

Homogeneity:Good

2% Chrysotile 98% Non-Fibrous Material B

Layer 3

Homogeneity:Good

Not Detected 100% Cellulose B

Composite Asbestos < 1% B

01-WB5-04. Drywall with Joint Compound; Unit 138 - East Wall 20617329-1

Layer 1 White Drywall with Brown Paper Homogeneity:Good

Not Detected 85% Non-Fibrous Material

B

Comments: A)Composite content provided does not follow the guidelines set forth by NVLAP. This analysis was performed by following the NESHAP guidelines. B) Composite asbestos content provided is only for Drywall/Joint compound. Composite content provided does not follow the guidelines set forth by NVLAP.

This analysis was performed by following the NESHAP guidelines.

EMLab ID: 4128787, Page 2 of 39Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230.03.2 - 128-140 S Clairborne Rd

Date of Receipt: 06-30-2025 Date of Report: 07-08-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

01-WB5-04. Drywall with Joint Compound; Unit 138 - East Wall 20617329-1(cont.)

Layer 2 White Joint Compound

Not Detected 100% Non-Fibrous Material A

Homogeneity:Good

Not Detected 100% Cellulose A

Composite Asbestos ND A

01-WB5-05. Drywall with Joint Compound; Unit 132 - West Wall, Central…