This federal contract opportunity is a solicitation for the construction of Phase II of the Georgia National Cemetery expansion in Canton, Georgia. The solicitation seeks the construction of approximately 6,624 pre-placed double-depth crypts in 3'x8' plots, 362 oversized preplaced double-depth crypts in 5'x10' plots, 294 traditional full casket gravesites in 5'x10' plots, 6,944 in-ground cremation sites in 4'x4' plots, and 7,300 columbarium niches. The solicitation also includes associated site and infrastructure requirements. The contracting agency is the Department of Veterans Affairs National Cemetery Administration.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
922CM3006
JDL CCT Dwg. of 178
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9
GEORGIA NATIONAL CEMETERY
CONSTRUCTION DOCUMENTS
FOR PHASE 2
Fil e P ath : O
:\G
OR
DO
N\
GE
OR
GI
AN
C\ P-
GA
NC
.D W
G
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
FEBRUARY 28, 2022
BID DOCUMENTS SUBMISSION
LI502
BID DOCUMENTS
CHEROKEE COUNTY, GEORGIA
The LA Group
(518) 587-8100
RVi
(512) 480-0032
Leo A Daly
(402) 391-8111
Aqua Engineering
(970) 372-6104
Ce rt i f ie d Irrigat ion Designer
I R R
I G AT I O N A S S OC I A T I O
NCID
46102
JO
HN D. LEONARD
2022/02/28
IRRIGATION DETAILS
1 SPRAY SPRINKLER
ASSEMBLY N.T.S. 2 ROTOR SPRINKLER
ASSEMBLY N.T.S. 3 ROTOR SPRINKLER IN IRRIGATION AISLE
ASSEMBLY N.T.S.
4 SPRINKLER PLACEMENT IN IRRIGATION AISLE
ASSEMBLY N.T.S.
54" MIN.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
922CM3006
JDL CCT Dwg. of 178
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9
GEORGIA NATIONAL CEMETERY
CONSTRUCTION DOCUMENTS
FOR PHASE 2
Fil e P ath : O
:\G
OR
DO
N\
GE
OR
GI
AN
C\ P-
GA
NC
.D W
G
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
FEBRUARY 28, 2022
BID DOCUMENTS SUBMISSION
LI503
BID DOCUMENTS
CHEROKEE COUNTY, GEORGIA
The LA Group
(518) 587-8100
RVi
(512) 480-0032
Leo A Daly
(402) 391-8111
Aqua Engineering
(970) 372-6104
Ce rt i f ie d Irrigat ion Designer
I R R
I G AT I O N A S S OC I A T I O
NCID
46102
JO
HN D. LEONARD
2022/02/28
IRRIGATION DETAILS
1 IRRIGATION CONTROLLER
ASSEMBLY N.T.S. 2 CONTROLLER GROUNDING
ASSEMBLY N.T.S. 3 RESTRAINED CASING SPACER
ASSEMBLY N.T.S.
4 FLOWER WATER STATION
ASSEMBLY N.T.S.
GENERAL SYMBOLS
SCALE:
B2
VIEW NAME
1/8" = 1'-0"
A4
EARTH
EARTH GRAVEL
CONCRETE
METALS
BRICK
CMU
TILE
STONE
WOOD
GYPSUM
GLASS
INSULATION
REGULAR
STEEL ALUMINUM
FACE COMMON
CMU
CERAMIC
MARBLE LIMESTONE
FINISH BLOCKING
PLASTER OR GWB
LARGE SCALE SMALL SCALE
BATT OR
LOOSE
RIGID
SURFACE
DETAIL TITLE
BUILDING SECTION
WALL SECTION
EXTERIOR / INTERIOR
ELEVATION
INTERIOR MULTI-VIEW
ELEVATION
MATERIALS REFERENCE
DETAIL SECTION
AE402
C4
AE201
A1
AE305
SIM
A1
AE305
SIM
A1
AE305
SIM
AE505
C3
A3
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS DRAWN
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS DRAWN
ACTUAL SQ. FT.
PROGRAMMED SQ. FT.
ROOM NUMBER
DOOR NUMBER
KEYNOTE
WALL TYPE
REVISION NUMBER
ELEVATION INDICATION
COLUMN GRID
IDENTIFICATION
NORTH ARROW
WINDOW NUMBER
A1
EQUIPMENT TAG
D
NTRUE
NORTH
MATCHLINE
FINISH , FINISH MATERIAL FINISH EXTENTS
SPRAY FOAM
B
5E
1t
S
W1
ROOM NAME
A505B
200 SF / 150 SF
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
CHEROKEE COUNTY, GEORGIA
922CM3006
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS SUBMISSION
GEORGIA NATIONAL CEMETERY
CONSTRUCTION DOCUMENTS
FOR PHASE 2
F ile
P at h:
G
:\P R
O
JE
C T
\S B
U \E
N G
IN
\3
1\
\S E
N T
\2
1-
-0 1_
T
IT
LE
B
LO
C
K \9
C
M
_G
-T T
LB
.D
W G
The LA Group
(518) 587-8100
RVi
(512) 480-0032
Leo A Daly
(402) 391-8111
Aqua Engineering
(970) 372-6104
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Gordon 148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Project No.003-10230-003
FEBRUARY 28, 2022
BID DOCUMENTS
GENERAL NOTES, SYMBOLS AND
ABBREVIATIONS
G-001
KCWMAC
A
A/C AIR CONDITIONING
AB ANCHOR BOLT / AIR BLENDER
ABS ACRYLONITRILE-BUTADIENE-STYRENE
AC ALTERNATING CURRENT / AIR COMPRESSOR
ACMU ARCHITECTURAL CONCRETE MASONRY UNIT
ACP ASBESTOS CEMENT PIPE
ACT ACOUSTICAL CEILING TILE
ACU AIR CONDITIONING UNIT
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJACENT / ADJUSTABLE
ADR ACCESS DOOR
AFF ABOVE FINISH FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
APPROX APPROXIMATELY
APT APARTMENT
ARCH ARCHITECT(URAL)
ASPH ASPHALT
ATB AIR TERMINAL BOX
ATC ACOUSTICAL TILE CEILING
ATD AIR TRANSFER DUCT
ATU AIR TERMINAL UNIT
AUX AUXILIARY
AVG AVERAGE
AWT ACOUSTICAL WALL TREATMENT
AZ AZIMUTH
B
BB BALLED AND BURLAPPED
BD BOARD
BDD BACK DRAFT DAMPER
BE BOTTOM ELEVATION
BL BUILDING LINE
BLDG BUILDING
BLKG BLOCKING
BM BENCH MARK / BEAM
BR BARE ROOT
BRG BEARING
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
C
C/C CENTER TO CENTER
CAB CABINET
CB CIRCUIT BREAKER / CATCH BASIN
CC COOLING UNIT
CE COVER ELEVATION
CEM CEMENT
CFM CUBIC FEET PER MINUTE
CG CORNER GUARD
CH CHILLER
CI CURB INLET / CAST IRON
CIP CAST IRON PIPE
CJ CONTROL JOINT OR CONTRACTION JOINT
CKT CIRCUIT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CM CENTIMETER
CMH CUBIC METER PER HOUR
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT / CARBON MONOXIDE
CO2 CARBON DIOXIDE
COL COLUMN
COMB COMBINATION / COMBINE
COMP COMPRESSIBLE
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS / CONTINUATION
CONTR CONTRACTOR
CORR CORRIDOR
ABBREVIATIONS
CP CARPET
CR CRASH RAIL
CS CONCRETE SEALER
CSF CUBIC FEET PER SECOND
CT CERAMIC TILE / COOLING TOWER
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CTW CERAMIC TILE WALL
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CUYD CUBIC YARD
CW COLD WATER
D
D DRAIN / DIFFUSER
DA DENTAL AIR
DBL DOUBLE
DEPR DEPRESSED
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIP DUCTILE IRON PIPE
DISC DISCONNECT
DISP DISPENSER
DIST DISTRIBUTION
DK DECK
DL DEAD LOAD
DN DOWN
DO DITTO
DPR DAMPER
DR DOOR
DS DOWNSPOUT
DV DENTAL VACUUM
DWG DRAWING
DWL DOWEL
DWP DOMESTIC WATER PUMP
E
EA EACH / EXHAUST AIR
ECT ENTRY CARPET TILE
EF EACH FACE / EXHAUST FAN
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EMBED EMBEDMENT
EMD ESTIMATED MAXIMUM DEMAND
EMT ELECTRICAL METAL TUBING
ENG ENTRANCE GRATING
EP EPOXY PAINT
EQ EQUAL
EQUIP EQUIPMENT
ET EXPANSION TANK / EPOXY TERRAZZO
ETB EPOXY TERRAZZO INTEGRAL COVE BASE
EVAC MEDICAL GAS EVACUATION
EW EACH WAY
EWC ELECTRICAL WATER COOLER
EWH ELECTRICAL WATER HEATER
EXH EXHAUST
EXP EXPOSED
EXPN EXPANSION
EXST EXISTING
EXT EXTERIOR
F
F FIRE MAIN
FA FIRE ALARM
FCU FAN COIL UNIT
FD FLOOR DRAIN / FIRE DAMPER
FD / SD COMBINATION FIRE AND SMOKE DAMPER
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FDR FEEDER
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH
FIX FIXTURE
FL FLOOR
FM FORCE MAIN / FACTORY MUTUAL
FP FIREPROOFING / FIRE PUMP
FPM FEET PER MINUTE
FR FIRE RATED
FRP FIBERGLASS REINFORCED PLASTIC
FS FLOW SWITCH
FT FEET
FTG FOOTING
FVC FIRE VALVE CABINET
G
G GAS / GRILLE
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GBD GRAVITY BACKDRAFT DAMPER
GEN GENERATOR
GFRC GLASS FIBER REINFORCED CONCRETE
GI GALVANIZED IRON
GL GLASS
GLB GLASS BLOCK
GLP GLASS PANEL
GLT GLASS TILE
GP GLAZED PAINT
GPM GALLONS PER MINUTE
GR GRADE
GRV GRAVITY ROOF VENTILATOR
GT GROUT
GWB GYPSUM WALLBOARD
GYP GYPSUM
H
HB HOSE BIBB
HC HEATING COIL
HDNR HARDENER
HDW HARDWARE
HDWD HARDWOOD
HK1E HOOK ONE END
HK2E HOOK TWO ENDS
HM HOLLOW METAL
HNDRL HANDRAIL
HORIZ HORIZONTAL
HP HORSEPOWER
HPT HIGH POINT
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING, VENTILATING AND AIR CONDITIONING
HW HOT WATER
HWC HOT WATER CIRCULATING
HZ HERTZ
I
IA INSTRUMENT AIR
IC INTERCOM
ID INSIDE DIAMETER
IE INVERT ELEVATION
IF INSIDE FACE
IN INCH
INSUL INSULATION
INT INTERIOR
J
JAN JANITOR
JB JUNCTION BOX
JP JOCKEY PUMP
JST JOIST
JT JOINT
K
KC MIL THOUSAND CIRCULAR MILS
KCJ KEYED CONSTRUCTION JOINT
KIT KITCHEN
KPA KILOPASCALS
KS KITCHEN SINK
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATTS
L
L LITER
LA LABORATORY AIR
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LBS POUNDS
LF LINEAR FEET
LIN LINEAR
LINO LINOLEUM
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMU LIGHTWEIGHT MASONRY UNITS
LONG LONGITUDINAL
LPM LITERS PER MINUTE
LT LIGHT
LT WT LIGHT WEIGHT
LTG LIGHTING
LV LABORATORY VACUUM
LVL LEVEL
LVT LUXURY VINYL TILE
M
M METER
M2 SQUARE METER
M3 CUBIC METER
MA MEDICAL AIR
MAINT MAINTENANCE
MAR MARBLE
MAS MASONRY
MAT MATERIAL
MAX MAXIMUM
MB MARBLE
MBH 1000 BTUH
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MET METAL
MFR MANUFACTURER
MG MOTOR GENERATOR / MEDICAL GAS
MH MANHOLE
MIN MINIMUM
MLO MAIN LUGS ONLY
MM MILLIMETER
MO MASONRY OPENING
MP METAL PANEL
MSP1 METAL SOFFIT PANEL TYPE 1
MSP2 METAL SOFFIT PANEL TYPE 2
MT METAL TRANSITION
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MV MEDICAL VACUUM
N
N NITROGEN
N2O NITROUS OXIDE
NEC NATIONAL ELECTRICAL CODE
NFPA NATIONAL FIRE PROTECTION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
O/S OFFSET
OA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE
OX OXYGEN
OZ OUNCE
P
P PAINT / PUMP / PENDANT
PA PASCAL
PART PARTITION
PAVT PAVEMENT
PC POINT OF CURVATURE / PRIVACY CURTAIN
PCF POUNDS PER CUBIC FOOT
PED PEDESTAL
PERP PERPENDICULAR
PHC PREHEAT COIL
PHVAC PLUMBING, HEATING, VENTILATING AND AIR
CONDITIONING
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE
PKG PARKING
PL PLASTIC LAMINATE / PROPERTY LINE / PLATE
PLAS PLASTER
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PNL PANEL
POL CONC POLISHED CONCRETE
PPT PORCELAIN PAVER TILE
PR PAIR
PRF POURED RESINOUS FLOORING
PROJ PROJECTION
PRV PRESSURE REGULATING VALVE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT OF TANGENCY
PTVC POINT OF VERTICAL CURVATURE
PTW PORCELAIN TILE WALL
PVC POLYVINYL CHLORIDE
PVI POINT OF VERTICAL INTERSECTION
PVT POINT OF VERTICAL TANGENCY
Q
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QZP QUARTZ POLYMER
R
R RADIUS / REGISTER
RA RETURN AIR
RAF RAISED ACCESS FLOORING
RB RUBBER BASE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
REF REFERENCE
REFL REFLECTED
REG REGISTER
REINF REINFORCED
REQD REQUIRED
REV REVERSE / REVISION
RF RETURN FAN
RGS RIGID GALVANIZED STEEL
RH ROOF HOOD / RELATIVE HUMIDITY / REHEAT
RHC REHEAT COIL
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RS RESILIENT SHEET
RT RESILIENT TILE
S
S STAIR / SURFACE / SANITARY
SA SUPPLY AIR / SOUND ATTENUATOR
SAN SANITARY
SCH SCHEDULE
SD SMOKE DAMPER / SUB DRAIN / STORM SEWER
SECT SECTION
SF SUPPLY FAN / STONE
SHT SHEET
SIM SIMILAR
SOG SLAB-ON-GRADE
SP SUMP PUMP
SPEC SPECIFICATIONS
SQ SQUARE
SS SERVICE SINK / SANITARY SEWER
SSM SOLID SURFACE MATERIAL
SSO STORM SEWER OVERFLOW
SST STAIR TREAD
SSTL STAINLESS STEEL
ST STAIN
STA STATION
STD STANDARD
STE STANDARD TAPERED END
STIFF STIFFENER
STIR STIRRUP
STL STEEL
STOR STORAGE
STR STRUCTURAL
SUSP SUSPENDED
SW SWITCH
SWGR SWITCHGEAR
SYM SYMMETRICAL
T
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TC TOP OF CURB
TE TOP ELEVATION
TEL TELEPHONE
TEMP TEMPERATURE
TERR TERRAZZO
TLT TOILET
TOPO TOPOGRAPHY
TOS TOP OF STEEL
TOW TOP OF WALL
TP TOP OF PAVEMENT
TRANS TRANSVERSE
TS TRANSITION STRIP
TYP TYPICAL
U
UC UNDERCUT
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UR URINAL
UV UNIT VENTILATOR
V
V VOLT
VAV VARIABLE AIR VOLUME
VC VERTICAL CURVE
VCP VITRIFIED CLAY PIPE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY DRIVE
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W
W WATT / WATER
W/ WITH
W/O WITHOUT
WAGD WASTE ANESTHESIA GAS DISPOSAL
WC WATER CLOSET / WALL COVERING
WD WOOD
WDB WOOD BASE
WDF WOOD FLOOR
WDP WOOD PANEL
WDW WINDOW
WDWF WINDOW FILM
WGD WALL GUARD
WH WATER HEATER / WALL HYDRANT
WP WEATHERPROOF
WPFG WATERPROOFING
WS WATER STOP
WT WEIGHT / WINDOW TREATMENT
WWF WELDED WIRE FABRIC
X
XFMR TRANSFORMER
Y
YD YARD
YH YARD HYDRANT
1. FOR EXIT LIGHTS AND EMERGENCY LIGHTING, SEE ELECTRICAL.
LIFE SAFETY GENERAL NOTES
OCCUPANCY
B
AREA NAME
150 SF 00
00 OCC.
EGRESS PATH WITH NAME, SEGMENT LENGTH, AND
DIRECTION INDICATED
IBC OCCUPANCY GROUP
ROOM (NET) AND AREA (GROSS) TAGS INDICATING SQUARE
FOOTAGE / OCCUPANCY LOAD FACTOR, AND RESULTING
OCCUPANCY BELOW
CODE ANALYIS LEGEND
PATH A
PROJECT SCOPE OF WORK:
PUBLIC INFORMATION CENTER
THE PROPOSED ADDITION TO THE EXISTING BUILDING, APPROXIMATELY 264 SQUARE FEET, INCLUDES
TWO SMALL MEETING ROOMS.
ADMINISTRATION MAINTENANCE COMPLEX
WORK IN THE ADMINISTRATION AND MAINTENANCE BUILDING IS LIMITED TO AN INTERIOR REFRESH, NO HEAVY DEMOLITION OR RENOVATION. SCOPE INCLUDES NEW PARTITIONS, DOORS AND FINISHES IN THE
CONFERENCE ROOM AND OFFICE, AND ASSOCIATED MECHANICAL AND ELECTRICAL WORK.
1.1 APPLICABLE CODES & STANDARDS
1.1.1 INTERNATIONAL BUILDING CODE, 2018 EDITION, WITH LOCAL AMENDMENTS (IBC)
1.1.2 INTERNATIONAL FIRE CODE, 2018 EDITION, WITH LOCAL AMENDMENTS (IFC)
1.1.3 INTERNATIONAL ENERGY CODE, 2015 EDITION, WITH LOCAL AMENDMENTS(IECC)
1.1.4 INTERNATIONAL PLUMBING CODE, 2018 EDITION, WITH LOCAL AMENDMENTS (IPC)
1.1.5 INTERNATIONAL FUEL GAS CODE, 2018 EDITION, WITH LOCAL AMENDMENTS (IFGC)
1.1.6 INTERNATIONAL MECHANICAL CODE, 2018 EDITION, WITH LOCAL AMENDMENTS (IMC)
1.1.7 2018 NFPA 101 LIFE SAFETY CODE
1.1.8 ABA AMERICAN BARRIERS ACT PG-18-13
1.1.9 VA PROGRAM GUIDE PG-18-3, PG-18-4, PG-18-15
1.1.10 VA SUSTAINABLE DESIGN MANUAL (REV1 AUGUST 18, 2017)
1.1.11 VA DESIGN AND CONSTRUCTION CRITERIA, NCA SPECIFIC CRITERIA AND SPECIFICATIONS
1.1.12 VA PROGRAM GUIDE 18-10
1.1.13 NATIONAL CEMETERY SIGNS
1.2 OCCUPANCY CLASSIFICATION
PUBLIC INFORMATION CENTER
1.2.1 BUSINESS - B
ADMINISTRATION AND MAINTENANCE BUILDING
1.2.2 BUSINESS - B
ASSEMBLY - A
1.2 OCCUPANCY LOAD
PUBLIC INFORMATION CENTER
1.2.1 BUSINESS - 11 OCCUPANTS
ADMINISTRATION AND MAINTENANCE BUILDING
1.2.2 BUSINESS - B - 21 OCCUPANTS
ASSEMBLY - A - 8 OCCUPANTS
1.3 CONSTRUCTION TYPE
IBC CHAPTER 6
1.5.1 TYPE II-B NON-SPRINKLED
1.6 FIRE RESISTIVE REQUIREMENTS
IBC CHAPTER 6 TABLE 601
1.6.1 PRIMARY STRUCTURAL FRAME = 0-HOUR RATING
1.6.2 BEARING WALLS, EXTERIOR = 0-HOUR RATING
1.6.3 BEARING WALLS, INTERIOR = 0-HOUR RATING
1.6.4 NON-BEARING WALLS & PARTITIONS, EXTERIOR = 0-HOUR RATING
1.6.5 NON-BEARING WALLS & PARTITIONS, INTERIOR = 0-HOUR RATING
1.6.6 FLOOR CONSTRUCTION = 0-HOUR RATING
1.6.7 ROOF CONSTRUCTION = 0-HOUR RATING
1.6 MEANS OF EGRESS
IBC CHAPTER 10
1.6.1 MINIMUM NUMBER OF EXITS:
BASED ON SECTION 1006.2
PUBLIC INFORMATION CENTER B = 1 REQUIRED, 3 TOTAL PROVIDED
ADMINISTRATION MAINTENANCE COMPLEX B = 1 REQUIRED, 2 TOTAL PROVIDED
1.6.2 MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE:
TABLE 1006.2.1
PUBLIC INFORMATION CENTER
B OCCUPANCY ALLOWABLE = 100', ACTUAL = 0'
ADMINISTRATION MAINTENANCE COMPLEX
B OCCUPANCY ALLOWABLE = 100', ACTUAL = 14'-7"
1.6.3 MAXIMUM DEAD END CORRIDOR DISTANCE:
SECTION 1020.4
B = 20'
1.6.4 EXIT ACCESS TRAVEL DISTANCE:
TABLE 1017.2
B OCCUPANCY, NON-SPRINKLED ALLOWABLE = 200'
1.6.5 PUBLIC INFORMATION CENTER
REQUIRED EGRESS: 11 OCCUPANTS x 0.2 = 2.2"
MINIMUM DOOR CLEAR WIDTH, SECTION 1010.1.1: 32"
PROVIDED EGRESS DOOR WIDTH: 130"
ADMINISTRATION MAINTENANCE COMPLEX
REQUIRED EGRESS: 29 OCCUPANTS x 0.2 = 5.8"
MINIMUM DOOR CLEAR WIDTH, SECTION 1010.1.1: 32"
PROVIDED EGRESS DOOR WIDTH: 96"
/675 SF
BUSINESS
7 OCC.
TD=47'-6"
OCCUPANCY
B
121 SF
FAMILY RM
PIC02
121 SF
FAMILY RM
PIC01
2 OCC2 OCC
EXIT WIDTH = 35"
CAPACITY = 175
EXIT WIDTH = 35"
CAPACITY = 175
EXIT WIDTH = 5'-0"
CAPACITY = 300
/592 SF
BUSINESS
6 OCC.
OCCUPANCY
B
TD = 46'-11"
C P
4' -7
84 SF
OFFICE
ADM02
EXIT WIDTH = 5'-0"
CAPACITY = 300
1 OCC
8 OCC
EXIT WIDTH = 3'-0"
CAPACITY = 180
/1909 SF
BUSINESS
20 OCC.
117 SF
CONFERENCE
ROOM
ADM01
OCCUPANCY
B
OCCUPANCY
A
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
CHEROKEE COUNTY, GEORGIA
922CM3006
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS SUBMISSION
GEORGIA NATIONAL CEMETERY
CONSTRUCTION DOCUMENTS
FOR PHASE 2
F ile
P at h:
G
:\P R
O
JE
C T
\S B
U \E
N G
IN
\3
1\
\S E
N T
\2
1-
-0 1_
T
IT
LE
B
LO
C
K \9
C
M
_G
-T T
LB
.D
W G
The LA Group
(518) 587-8100
RVi
(512) 480-0032
Leo A Daly
(402) 391-8111
Aqua Engineering
(970) 372-6104
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Gordon 148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Project No.003-10230-003
FEBRUARY 28, 2022
BID DOCUMENTS
LIFE SAFETY PLAN (ADD ALTERNATE)
G-002
KCWMAC
SCALE: 1/8" = 1'-0"
F1
CODE AND LIFE SAFETY PLAN - PUBLIC INFORMATION CENTER (ADD ALTERNATE B)
SCALE: 1/8" = 1'-0"
F5
CODE AND LIFE SAFETY PLAN - ADMIN/MAINTENANCE COMPLEX (ADD ALTERNATE A)
2'
SCALE : 1/4" = 1'-0"
0 4' 8'
NTRUE
NORTH
N TRUE
NORTH
010000 - GENERAL REQUIREMENTS AND DESIGN CRITERIA
1. APPLICABLE BUILDING CODE AND SELECT REFERENCING STANDARDS
INTERNATIONAL BUILDING CODE, 2018 WITH GEORGIA AMENDMENTS
ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
AISC 360-16 SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS
ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES INCLUDING SUPPLEMENT NO. 1
AND 2, EXCLUDING CHAPTER 14 AND APPENDIX 11A
AWS D1.1-2011 STRUCTURAL WELDING CODE - STEEL
TMS 402-16 BUILDING CODE FOR MASONRY STRUCTURES
VA DESIGN INSTRUCTIONS TO ARCHITECTS AND ENGINEERS – STRUCTURAL DESIGN MANUAL FOR ANCILLARY
FACILITIES PROJECTS, FEBRUARY 1, 2014
AISC 303-10 CODE OF STANDARD PRACTICE FOR STRUCTURAL STEEL BUILDING AND BRIDGES
ACI 301-10 CODE OF STANDARD PRACTICE FOR REINFORCED CONCRETE BUILDINGS
OTHER SELECT REFERENCED STANDARDS MAY BE INDICATED ELSEWHERE IN THE CONTRACT DOCUMENTS, AS
APPLICABLE.
THE PROVISIONS OF THE REFERENCED BUILDING CODE AND ALL REFERENCED STANDARDS THEREIN SHALL APPLY TO THIS PROJECT. WHERE THERE IS A CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE APPLICABLE. TYPICALLY, THE LATEST EDITION OF CONSTRUCTION STANDARDS SHALL BE UTILIZED, AS APPROVED BY THE AUTHORITY HAVING JURISDICTION.
2. INTERPRETATION OF CONFLICTS:
SHOULD CONFLICTS OCCUR IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL REQUEST
INTERPRETATION BEFORE PROCEEDING WITH THE ASSOCIATED WORK. ALL SUCH REQUESTS SHALL FIRST BE PRECEDED BY A DILIGENT INVESTIGATION INTO THE CONTRACT DOCUMENTS. EVIDENCE OF SUCH
INVESTIGATION SHALL BE CONTAINED IN ALL REQUESTS FOR INTERPRETATION SUBMITTED.
IF THE CONTRACTOR FAILS TO MAKE SUCH A REQUEST, THE CONTRACTOR IS EXPECTED TO COMPLETE THE WORK AS INDICATED IN THE CONTRACT DOCUMENTS. SHOULD CONFLICTS OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS, THE CONTRACTOR SHALL ESTIMATE THE COST OF THE WORK BASED ON THE MORE EXPENSIVE WAY OF DOING THE WORK UNLESS HAVING ASKED FOR, AND OBTAINED, WRITTEN DECISION
BEFORE SUBMISSION OF PROPOSAL AS TO WHICH METHOD OR MATERIALS WILL BE REQUIRED.
3. STRUCTURAL SYSTEMS HAVE BEEN DESIGNED TO RESIST THE FOLLOWINGS DESIGN LOADS:
A. FLOOR LIVE LOADS
THE "TYPICAL MINIMUM LIVE LOAD USED FOR DESIGN" INDICATED BELOW WAS USED FOR ALL OCCUPANCY OR USE TYPES, EXCEPT THOSE WHERE THE "CODE-SPECIFIED MINIMUM LIVE LOADS" ARE GREATER, IN WHICH CASE THE ASSOCIATED LIVE LOAD INDICATED IN THE TABLE WAS USED FOR DESIGN. SEE
ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR THE DEFINITION OF SPACES.
TYPICAL MINIMUM LIVE LOAD USED FOR DESIGN = 100 PSF, 1000 LB CONCENTRATED LOAD
* UNLESS OTHERWISE INDICATED, THE CONCENTRATED LOAD INDICATED WAS DISTRIBUTED OVER AN AREA OF 2.5 FEET BY 2.5 FEET (6.25 SQUARE FEET), AND LOCATED AS TO PROVIDE THE MAXIMUM LOAD
EFFECTS IN THE STRUCTURAL MEMBERS.
** PROVISIONS FOR MOVEABLE PARTITIONS ARE NOT INCLUDED.
PER SECTION 106.1 OF IBC, AN APPROVED (ALLOWABLE) LIVE LOAD POSTING SHALL BE PROVIDED PROMINENTLY IN ALL PORTIONS OF FLOORS AND ROOFS WHERE DESIGN LIVE LOADS (OR ROOF LIVE LOADS) INDICATED IN THE DESIGN LOADS SECTION OF THESE STRUCTURAL GENERAL NOTES ARE GREATER THAN 50 PSF. EACH CONTIGUOUS PORTION OF THE FLOOR WITH THE SAME LIVE LOAD EXCEEDING 50 PSF SHALL HAVE A SIGN PROMINENTLY POSTED AT THE MAIN ENTRANCE TO THAT
RESPECTIVE AREA, AS APPROVED BY THE BUILDING OFFICIAL.
SIGN SHALL INDICATE THE APPROVED (ALLOWABLE) LIVE LOAD VALUE AS INDICATED IN THE DESIGN
LOADS SECTION OF THESE STRUCTURAL GENERAL NOTES THAT ARE GREATER THAN 50 PSF.
B. ROOF LIVE LOADS
20 PSF MINIMUM ROOF LIVE LOAD
C. LIVE LOAD REDUCTIONS WERE NOT APPLIED.
D. ROOF SNOW LOADS, APPLIED IN ACCORDANCE WITH THE BUILDING CODE INDICATED HEREIN.
GROUND SNOW LOAD, Pg = 5 PSF FLAT ROOF SNOW LOAD, Pf = 8.5 PSF* SNOW EXPOSURE FACTOR, Ce = 1.0
SNOW IMPORTANCE FACTOR, I = 1.0
THERMAL FACTOR, Ct = 1.0
*A 5 PSF RAIN-ON-SNOW SURCHARGE LOAD HAS BEEN INCLUDED IN ACCORDANCE WITH CHAPTER 7 OF
ASCE 7.
SNOW LOADS ARE NOT REDUCIBLE.
E. INTERIOR WALLS
5 PSF LATERAL LOAD IN THE ABSENCE OF ANY WIND LOAD EFFECTS
F. WIND LOADS. APPLIED IN ACCORDANCE WITH THE BUILDING CODE INDICATED HEREIN.
BASIC WIND SPEED, Vult = 105 MPH -Vasd = 81 MPH -Vdrift = 72 MPH (10 - YR MRI WIND)
WIND IMPORTANCE FACTOR, I = 1.0
RISK CATEGORY = II
WIND EXPOSURE = B
INTERNAL PRESSURE COEFFICIENT, GPi = +/-0.18
G. COMPONENTS AND CLADDING WIND LOADS:
* PRESSURES SHOWN ARE APPLIED NORMAL TO THE SURFACE. PLUS AND MINUS SIGNS SIGNIFY
PRESSURES ACTING TOWARD AND AWAY FROM THE SURFACES, RESPECTIVELY.
** SEE ASCE 7 FOR DEFINITION. FOR EFFECTIVE WIND AREAS BETWEEN THOSE GIVEN, VALUES MAY BE LINEARLY INTERPOLATED, OTHERWISE USE VALUES ASSOCIATED WITH THE LOWER EFFECTIVE WIND
AREA.
H. SEISMIC LOADS. APPLIED IN ACCORDANCE WITH THE BUILDING CODE INDICATED HEREIN.
SEISMIC IMPORTANCE FACTOR, Ie = 1.0
RISK CATEGORY = II
MAPPED SPECTRAL RESPONSE ACCELERATIONS
-SHORT PERIOD, Ss = 0.271g -ONE-SECOND PERIOD, S1 = 0.095g
SPECTRAL RESPONSE COEFFICIENTS
-SHORT PERIOD, SDS = 0.235g -ONE-SECOND PERIOD, SD1 = 0.095g
SEISMIC DESIGN CATEGORY, SDC = B
BASIC SEISMIC-FORCE-RESISTING SYSTEM(S) = ORDINARY REINFORCED MASONRY SHEAR WALLS
DESIGN BASE SHEAR, V = 5 KIPS
SEISMIC RESPONSE COEFFICIENT(S), Cs = 0.117g
RESPONSE MODIFICATION FACTOR, R = 2.0
LONG-PERIOD TRANSITION = 12 SEC PERIOD, TL
ANALYSIS PROCEDURE USED : EQUIVALENT LATERAL FORCE PROCEDURE
SITE CLASS: C (ASSUMED BASED ON EXISTING DRAWINGS)
6. DESIGN ITEMS DELEGATED TO THE CONTRACTOR
THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF THE FOLLOWING ITEMS. DESIGNS SHALL SATISFY
THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
A. COLD-FORMED STEEL JOIST/STUD/TRUSS FRAMING AND PRE-FABRICATED COMPONENTS
B. SITE SEGMENTAL RETAINING WALL (SEE BASIS OF DESIGN ON SHEET SB100)
C. MARQUEE SIGN WITH CANOPY (SEE LANDSCAPE DRAWINGS)
D. HANDRAILS AND GUARDRAILS
E. PRECAST COMPONENTS AND THEIR CONNECTION TO STRUCTURE
ALL ITEMS LISTED AS DELEGATED DESIGN ITEMS SHALL BE PERFORMED AND STAMPED BY A STRUCTURAL ENGINEER LICENSED IN THE PROJECT STATE. STAMPED ENGINEERING CALCULATIONS SHALL BE SUBMITTED FOR REVIEW AT THE SAME TIME THAT RELATED SHOP DRAWINGS ARE SUBMITTED FOR
REVIEW.
7. CONTRACTOR RESPONSIBILITIES
A. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS (INCLUDING FIELD VERIFICATIONS OF EXISTING
CONDITIONS AND DIMENSIONS) BEFORE STARTING WORK OR FABRICATING ANY REINFORCING STEEL, STRUCTURAL STEEL, COLD-FORMED STEEL ELEMENTS, OR PRECAST ELEMENTS. THE ARCHITECT SHALL
BE NOTIFIED OF ANY DISCREPANCIES FOUND.
B. SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF WALL, ROOF, AND FLOOR OPENINGS AND SLEEVES, AND CONCRETE PADS UNDER EQUIPMENT. THE
CONTRACTOR SHALL VERIFY EXACT SIZE AND LOCATION WITH EQUIPMENT FURNISHED. OPENINGS IN
STRUCTURE TO BE HANDLED AS FOLLOWS:
OPENINGS THROUGH CONCRETE WALLS, FLOORS, AND ROOFS, WHICH MEASURE 12" OR LESS IN ALL
DIRECTIONS, SHALL BE CORE DRILLED.
OPENINGS THROUGH METAL ROOF DECK, WHICH MEASURE 6" OR LESS IN ALL DIRECTIONS, MAY BE CUT.
C. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING AND BRACING OF THE STRUCTURE, NEW AND/OR EXISTING, FOR ALL LOADS THAT MAY BE IMPOSED DURING CONSTRUCTION.
D. THE DIAPHRAGM PROVIDED BY THE METAL ROOF DECK IS REQUIRED TO BRACE THE WALLS AND COMPLETE THE LATERAL LOAD RESISTING SYSTEM OF THE STRUCTURE. THE CONTRACTOR SHALL PROVIDE LATERAL BRACING AS REQUIRED DURING CONSTRUCTION UNTIL THE METAL ROOF DECK HAS
BEEN CONSTRUCTED.
E. WHEN CUTTING A NEW OPENING IN EXISTING CONCRETE OR MASONRY, THE CONTRACTOR SHALL NOT OVER CUT AT CORNERS. CORE-DRILL, CHIP AND GRIND AS REQUIRED AT CORNERS. A LAYOUT OF ALL PROPOSED OPENINGS SHALL BE REVIEWED BY THE STRUCTURAL ENGINEER PRIOR TO SAWCUTTING.
F. ALL WALL FOOTINGS SHALL BE CENTERED ON WALLS UNLESS NOTED OTHERWISE.
G. CONTRACTOR SHALL ENSURE NO STRUCTURAL MEMBERS OR ELEMENTS ARE DAMAGED OR ALTERED
UNLESS SO INDICATED BY THE STRUCTURAL ENGINEER. ANY SUCH DAMAGE THAT DOES OCCUR SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER AND SHALL BE THE RESPONSIBILITY OF
THE CONTRACTOR.
8. PROVISIONS FOR FUTURE EXPANSION
A. NO PROVISIONS FOR FUTURE EXPANSION HAVE BEEN MADE IN THE STRUCTURAL SYSTEMS.
1 1
3 3
TYP
2'-6"
T Y
P
2' -6
TYP
2'-6"
ROOF LOADING DIAGRAM WALL LOADING DIAGRAM
014000 - QUALITY REQUIREMENTS
1. SPECIAL INSPECTIONS AND STRUCTURAL TESTING SHALL BE PERFORMED PER CHAPTER 17 OF IBC, THE CONTRACT DOCUMENTS, AND THE STATEMENT OF SPECIAL INSPECTIONS WHICH IS INCLUDED IN THE
CONTRACT DOCUMENTS.
033000 - CAST-IN-PLACE CONCRETE (REINFORCED)
1. ALL STRUCTURAL CONCRETE SHALL BE DESIGNED FOR A 28-DAY COMPRESSIVE STRENGTH OF:
f'c EQUALS 3500 PSI (NORMAL WEIGHT) AT INTERIOR SLABS-ON-GRADE f'c EQUALS 4500 PSI (NORMAL WEIGHT W/ ENTRAINED AIR) AT FOUNDATIONS, CONCRETE ASSOCIATED WITH
COLUMNBARIUM DETAILS, AND STOOP SLABS
f'c EQUALS 5000 PSI (NORMAL WEIGHT) FOR PRECAST
2. ALL REINFORCING STEEL SHALL BE DEFORMED, NEW, AND CONFORM TO ASTM A615 GRADE 60.
3. ALL PLAIN WELDED WIRE REINFORCEMENT SHALL BE NEW AND CONFORM TO ASTM A185.
4. ALL DEFORMED WELDED WIRE REINFORCEMENT SHALL BE NEW AND CONFORM TO ASTM A497.
5. DEFORMED BAR ANCHORS SHALL BE NEW AND CONFORM TO ASTM A706. WELDING OF DEFORMED BAR
ANCHORS SHALL BE DONE WITH E80XX ELECTRODES IN CONFORMANCE WITH THE AMERICAN WELDING SOCIETY (AWS) "STRUCTURAL WELDING CODE - REINFORCING STEEL" AWS D1.4 - LATEST EDITION.
6. HEADED DEFORMED BARS SHALL BE NEW AND CONFORM TO ASTM A615 GRADE 60, ASTM A706 GRADE 60 AND ASTM A970 INCLUDING ANNEX A1 REQUIREMENTS FOR CLASS HA HEAD DIMENSIONS. OBSTRUCTIONS OR INTERRUPTIONS OF THE BAR DEFORMATIONS, IF ANY, SHALL NOT EXTEND MORE THAN 2 BAR DIAMETERS FROM
THE BEARING FACE OF THE HEAD.
7. HEADED SHEAR STUDS SHALL CONFORM TO A.W.S. D1.1 - LATEST EDITION REQUIREMENTS FOR STANDARD
HEADED STUDS.
8. CONCRETE PROTECTIVE COVERING FOR REINFORCEMENT AT SURFACES NOT EXPOSED DIRECTLY TO EARTH OR WEATHER SHALL BE 3/4" FOR SLABS, JOISTS, AND WALLS AND 1 1/2" FOR BEAM STIRRUPS AND COLUMN TIES
OR SPIRALS, UNLESS DETAILED OTHERWISE.
9. CONCRETE PROTECTIVE COVERING FOR REINFORCEMENT AT SURFACES WHICH WILL BE EXPOSED TO THE WEATHER OR BE IN CONTACT WITH EARTH (BUT NOT CAST AGAINST) SHALL BE 2" FOR BARS LARGER THAN #5 AND 1 1/2" FOR #5 BARS OR SMALLER, PROVIDE 3" COVER FOR REINFORCEMENT CAST AGAINST AND
PERMANENTLY EXPOSED TO EARTH, UNLESS DETAILED OTHERWISE.
10. SLABS-ON-GRADE, UNLESS NOTED OTHERWISE, SHALL BE CONSTRUCTED OVER 6 INCHES OF GRANULAR FILL OVER VAPOR BARRIER. REINFORCING SHALL BE LAPPED AS PER TABLE BELOW. AT CONTRACTOR'S OPTION, MACRO SYNTHETIC FIBERS MAY BE SUBSTITUTED FOR NON-EXPOSED CONCRETE.
11. CONTRACTION JOINTS IN SLABS ON GRADE SHALL BE PLACED AT COLUMN LINE INTERSECTIONS AND AS NECESSARY TO NOT EXCEED A SPACING OF 36 TIMES THE SLAB THICKNESS OR 15'-0". WHICHEVER IS LESS.
MAXIMUM ASPECT RATIO SHALL BE 1.5 TO 1.0 UNLESS NOTED OTHERWISE.
12. PROVIDE 3/4-INCH CHAMFER ON ALL EXPOSED CONCRETE CORNERS EXCEPT WHERE MASONRY WALLS ARE
LAID FLUSH WITH COLUMN OR BEAM FACE.
13. FORMWORK SHALL BE ADJUSTED BEFORE AND AFTER CONCRETE PLACING OPERATIONS (PRIOR TO INITIAL SET) TO COMPENSATE FOR FORMWORK DEFLECTION, IN ADDITION TO ANY CAMBER SPECIFIED ON THE
DRAWINGS.
14. PROVIDE EXTERIOR CORNER BARS SAME SIZE AND SPACING AS HORIZONTAL REINFORCING AT ALL CONCRETE
WALLS AND FOOTINGS - LAP AS PER TABLE BELOW
15. PROVIDE LAP SPLICES IN CONFORMANCE WITH TABLE 033000-1, UNLESS OTHERWISE INDICATED. FOLLOW RESTRICTIONS ON LOCATIONS OF SPLICES AS INDICATED IN DETAILS, NOTES, OR SPECIFICATIONS.
16. WHERE REINFORCING STEEL IN TENSION IS REQUIRED TO BE MECHANICALLY SPLICED, MECHANICAL SPLICE SHALL BE DESIGNED FOR 125% OF THE SPECIFIED YIELD STRENGTH OF THE LARGER BAR BEING SPLICED.
17. NO PENETRATIONS (SUCH AS PIPE SLEEVES, ELECTRICAL CONDUITS, ETC.) THROUGH ANY STRUCTURAL
MEMBER, SHALL BE MADE WITHOUT APPROVAL BY THE STRUCTURAL ENGINEER.
042000 - UNIT MASONRY
1. HOLLOW CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90.
2. MORTAR SHALL CONFORM TO ASTM C270, TYPE S FOR MORTAR NOT IN CONTACT WITH EARTH AND TYPE M
FOR MORTAR IN CONTACT WITH EARTH.
3. NET AREA COMPRESSIVE STRENGTH OF CONCRETE MASONRY, f'm = 2000 PSI.
4. GROUT FOR REINFORCED CONCRETE MASONRY SHALL CONFORM TO ASTM C476, WITH A MINIMUM
COMPRESSIVE STRENGTH OF 2000 PSI.
5. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY SHORING NECESSARY TO LATERALLY SUPPORT ALL
CONCRETE MASONRY WALLS AS REQUIRED.
6. PROVIDE GALVANIZED HORIZONTAL JOINT REINFORCING EVERY 16 INCHES IN HEIGHT IN ALL WALLS, NO. 9
GAGE MINIMUM, UNLESS INDICATED OTHERWISE.
7. GROUT ALL CELLS FULL UNDER STEEL BEAMS BEARING ON CONCRETE MASONRY WITHIN AN AREA 24 INCHES
WIDE BY 24 INCHES HIGH.
8. REINFORCE ALL CONCRETE MASONRY WALLS WITH #5 VERTICAL REINFORCEMENT AS INDICATED IN GROUTED
CELLS. LAP AS SCHEDULED UNLESS OTHERWISE DETAILED. PLACE BOND BEAMS AT TOP REINFORCED WITH (2)-#4 x CONTINUOUS, AND AS DETAILED.
9. LINTELS FOR OPENINGS NOT DETAILED SHALL BE 16" DEEP WITH 2-#5 BOTTOM BARS.
10. PROVIDE LAP SPLICES OF REINFORCING STEEL IN CONFORMANCE WITH TABLE 042000-01, UNLESS OTHERWISE
INDICATED. FOLLOW RESTRICTIONS ON LOCATIONS OF SPLICES, AS INDICATED IN DETAILS, NOTES, AND
SPECIFICATIONS.
11. ALL CMU SHALL BE PLACED IN RUNNING BOND UNLESS SPECIFICALLY DETAILED ON THESE DRAWINGS.
051200 - STRUCTURAL STEEL FRAMING
1. ALL STRUCTURAL STEEL W SHAPES SHALL BE ASTM A992 (UNLESS NOTED OTHERWISE).
STRUCTURAL STEEL FOR CHANNELS, ANGLES AND PLATES SHALL BE ASTM A36 (UNLESS NOTED OTHERWISE).
WHERE PLATES ARE INDICATED WITH Fy = 50 KSI, THEY SHALL BE ASTM A572, GRADE 50.
2. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE C WITH A MINIMUM YIELD STRENGTH OF 46,000
PSI FOR ROUND SECTIONS, AND 50,000 PSI FOR SQUARE AND RECTANGULAR SECTIONS.
3. ALL ANCHOR RODS SHALL BE ASTM F1554, GRADE 55 UNLESS NOTED OTHERWISE.
4. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH "AISC 360-10, SPECIFICATION FOR
STRUCTURAL STEEL BUILDINGS, 2010". ALLOWABLE STRENGTH DESIGN METHOD.
5. ALL FIELD CONNECTIONS SHALL BE MADE WITH 3/4-INCH DIAMETER ASTM A325 BOLTS (BEARING TYPE
CONNECTION), UNLESS NOTED OTHERWISE. BOLTS SHALL BE TIGHTENED (SNUG-TIGHT) IN CONFORMANCE WITH "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" RESEARCH COUNCIL ON
STRUCTURAL CONNECTIONS OF THE ENGINEERING FOUNDATION.
6. ALL WELDING SHALL BE DONE WITH E70XX ELECTRODES IN CONFORMANCE WITH THE AMERICAN WELDING
SOCIETY (AWS) "STRUCTURAL WELDING CODE" AWS D1.1 - LATEST EDITION.
7. ALL RE-ENTRANT CORNERS OF BEAM COPES AND PLATE CUTS MUST BE SHAPED NOTCH-FREE PER AWS D1.1 TO A RADIUS. AN APPROXIMATE MINIMUM RADIUS TO WHICH THIS CORNER MUST BE SHAPED IS 1/2 INCH.
8. BEARING SURFACES OF COLUMNS SHALL BE FINISHED TO PROVIDE FULL BEARING CONTACT WITH BASE PLATE (AND CAP PLATE IF REQUIRED BY LOAD TRANSFER). BASE PLATES AND CAP PLATES SHALL BE FINISHED IN
ACCORDANCE WITH SECTION M2.8 OF THE AISC SPECIFICATION.
9. ALL STEEL MEMBERS AND COMPONENTS EXPOSED TO EXTERIOR CONDITIONS WITHIN THE CAVITY OF THE EXTERIOR WALL OR LOCATED OUTSIDE THE EXTERIOR VAPOR BARRIER SHALL BE GALVANIZED. APPLY ZINC COATING BY THE HOT DIP PROCESS ACCORDING TO ASTM A123. AFTER ERECTION OF STEEL, REPAIR DAMAGED GALVANIZED COATING WITH GALVANIZED REPAIR PAINT. FILL ALL BENT HOLES THAT WILL NOT BE
COVERED BY CONCRETE IN FINISHED STRUCTURE.
10. ALL INTERIOR EXPOSED STEEL SHALL MEET PRIMING AND PAINTING REQUIREMENTS AS DEFINED IN THE
INTERIOR PAINTING SPECIFICATION.
053100 - STEEL DECKING
1. DESIGN AND CONSTRUCTION OF STEEL ROOF DECK SHALL CONFORM TO ANSI/SDI-RD1.0.
2. STEEL DECKING SHALL BE DESIGNED FOR THE FOLLOWING MINIMUM YIELD STRENGTHS:
Fy = 50 ksi (STEEL ROOF DECK)
3. ALL METAL DECKING SHALL BE GALVANIZED PER THE SPECIFICATIONS.
4. STEEL ROOF DECK (TYPE “1.5B”) SHALL BE 1.5 INCH, 20 GAUGE METAL DECK HAVING THE FOLLOWING MINIMUM
SECTION PROPERTIES:
Ip = 0.201 IN4/FT In = 0.222 IN4/FT Sp = 0.234 IN3/FT Sn = 0.247 IN3/FT p = FOR POSITIVE BENDING n = FOR NEGATIVE BENDING
ATTACH STEEL ROOF DECK USING THE FOLLOWING FASTENER PATTERN:
36/9 AT ENDS AND INTERMEDIATE SUPPORTS (12” TEK SCREW OR EQUIV.)
3 SIDE LAP FASTENERS EQUALLY SPACED PER SPAN (#10 TEK SCREW OR EQUIV.)
6. METAL DECK SHALL BE CONTINUOUS OVER A MINIMUM OF 3 SPANS, UNO.
7. STEEL ROOF DECK SHALL BE ANCHORED TO ROOF TO RESIST A GROSS UPLIFT LOAD AS INDICATED IN
SECTION 010000 ON SHEET S-001.
8. PROVIDE ADDITIONAL ANGLES TO SUPPORT DECKING AT AREAS WHERE DECK IS CUT FOR COLUMNS OR
OTHER PENETRATIONS TO PREVENT WEAKENED AREAS IN DECKING.
9. PROVIDE ALL NECESSARY DETAILS INCLUDING RIDGE AND VALLEY PLATES, CLOSURE PLATES AND ANY OTHER
ACCESSORIES REQUIRED FOR A FINISHED SURFACE FOR FLOOR OR ROOF INSTALLATION.
050519 - POST-INSTALLED ANCHORAGE
1. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED IN THE CONTRACT DOCUMENTS. THE
CONTRACTOR SHALL OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER-OF-RECORD PRIOR TO
INSTALLING POST-INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH EXISTING REBAR. ALL POST-INSTALLED ANCHORS (IN CONCRETE OR CMU) ARE TO BE INSTALLED IN STRICT CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS INCLUDING BUT NOT LIMITED TO DRILL BIT SIZE, PROPER CLEANING OF HOLES, INSTALLATION TORQUE, AND TEMPERATURE CONSTRAINTS.
2. ANCHOR CAPACITY IS DEPENDENT UPON SPACING BETWEEN ADJACENT ANCHORS AND PROXIMITY OF
ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE
CLEARANCES INDICATED ON THE DRAWINGS.
3. EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT WITH SPECIFIC ANCHOR LOCATIONS. UNLESS NOTED ON THE DRAWINGS THAT THE BARS CAN BE CUT, THE CONTRACTOR SHALL REVIEW THE EXISTING STRUCTURAL DRAWINGS AND SHALL UNDERTAKE TO LOCATE THE POSITION OF THE REINFORCING BARS AT THE LOCATIONS OF THE CONCRETE ANCHORS, BY FERROSCAN, GPR, X-RAY, CHIPPING
OR OTHER MEANS AS APPROVED BY THE STRUCTURAL ENGINEER OF RECORD.
316000 - GENERAL FOUNDATIONS
1. A SOILS INVESTIGATION WAS CONDUCTED BY ECS SOUTHEAST, LLP AND A GEOTECHNICAL ENGINEERING REPORT WAS PRODUCED AND DATED JANUARY 25, 2022. THE REPORT IS INCLUDED FOR INFORMATION WITHIN
SECTION 003132 'GEOTECHNICAL DATA'
2. EQUIVALENT FLUID PRESSURE FOR ACTIVE EARTH PRESSURE ON WALLS:
CANTILEVER RETAINING WALLS:
FOR STRUCTURAL DESIGN OF WALL = 40 PCF (DRAINED)
FOR STRUCTURAL STABILITY OF WALL = 40 PCF (DRAINED)
WALLS LATERALLY SUPPORTED TOP AND BOTTOM:
FOR STRUCTURAL DESIGN OF WALL = 60 PCF (DRAINED)
FOR STRUCTURAL STABILITY OF WALL = 60 PCF (DRAINED)
3. BACKFILLING AGAINST WALLS AND GRADE BEAMS SHALL NOT BE DONE UNTIL CONCRETE HAS ATTAINED SUFFICIENT STRENGTH AND WALLS ARE PROPERLY SHORED OR BRACED. WHERE BACKFILL IS REQUIRED ON
BOTH SIDES OF WALLS, BACKFILL BOTH SIDES SIMULTANEOUSLY.
4. UNDOCUMENTED FILL WAS IDENTIFIED DURING GEOTECHNICAL EXPLORATIONS AND WAS DETERMINED TO BE NOT SUITABLE TO SUPPORT FOUNDATIONS. IF UNDOCUMENTED FILL IS OBSERVED AT ANY BEARING ELEVATIONS FOR COLUMBARIUM AND BUILDING FOUNDATIONS, UNDERCUT AND REMOVE. BACKFILL WITH
SUITABLE SOILS AS DEFINED PER THE SPECIFICATIONS.
5. HIGHLY PLASTIC SOILS WERE IDENTIFIED DURING GEOTECHNICAL EXPLORATIONS. PROVIDE A MINIMUM 18 INCH SEPERATION LAYER BETWEEN BOTTOM OF FOOTINGS OR BOTTOMS OF SLABS ON GRADE AND PLASTIC SOILS. IF THESE SOILS ARE IDENTIFIED DURING EXACAVATION, UNDERCUT AND REMOVE AS REQUIRED.
BACKFILL WITH SUITABLE SOILS AS DEFINED PER THE SPECIFICATIONS.
6. ALL FOOTING EXCAVATIONS AND SLAB ON GRADE SUBGRADES SHALL BE INSPECTED BY A SPECIAL INSPECTOR ACCEPTABLE TO THE OWNER PRIOR TO CONSTRUCTION OF THE FOOTINGS AND SLABS. SPECIAL INSPECTOR SHALL VERIFY ALLOWABLE BEARING PRESSURES LISTED BELOW WERE ACHIEVED THROUGH
PROPER EARTHWORK.
7. IF ROCK MATERIAL IS ENCOUNTERED AT ANY FOUNDATION BEARING ELEVATIONS, UNDERCUT FOUNDATION AREA AND PROVIDE A MINIMUM OF 12" LAYER OF SUITABLE FILL AS DEFINED IN THE EARTHMOVING
SPECIFICATIONS.
316100 - SPREAD FOOTINGS
1. ALL FOOTINGS SHALL BEAR ON APPROVED NATIVE SOIL OR STRUCTURAL FILL. BOTTOM OF ALL EXTERIOR FOOTINGS SHALL BE AT LEAST 18" BELOW FINISHED GRADE. ELEVATIONS OF BOTTOM OF ALL FOOTINGS HAVE BEEN ESTIMATED BASED ON AVAILABLE INFORMATION AND SHALL NOT BE CONSTRUED AS WAIVING ANY OF THE MINIMUM REQUIREMENTS ON THESE DRAWINGS AND IN THE SPECIFICATIONS. ALL FOOTING EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY THE SPECIAL INSPECTOR PRIOR TO CONSTRUCTION OF THE FOOTINGS.
2. ALLOWABLE SOIL BEARING PRESSURE:
SPREAD AND CONTINUOUS FOOTINGS ON NATURAL SOIL= 3000 PSF (DEAD LOAD PLUS FULL LIVE LOAD)
SPREAD AND CONTINUOUS FOOTINGS ON STRUCTURAL FILL = 3000 PSF (DEAD LOAD PLUS FULL LIVE LOAD)
RETAINING WALLS = 3000 PSF (MAXIMUM TOE PRESSURE)
3. SLIDING COEFFICIENT OF FRICTION FOR SLIDING RESISTANCE = 0.32 (CONCRETE ON SOIL)
4. PASSIVE EQUIVALENT FLUID PRESSURE FOR SLIDING RESISTANCE = 360H (PSF)
054000 - COLD-FORMED METAL FRAMING
1. DESIGN: ALL STUDS, JOISTS, TRUSSES, AND CONNECTIONS, NOT SPECIFICALLY DETAILED ON THE DRAWINGS, SHALL BE DESIGNED FOR THE SPACINGS AND LOADS INDICATED, BY A REGISTERED PROFESSIONAL ENGINEER. DESIGN SHALL BE IN ACCORDANCE WITH AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS". STEEL STRUCTURAL
MEMBERS".
2. FIRE-RESISTANCE RATINGS: COMPLY WITH FIRE-RESISTANCE RATINGS AS INDICATED AND AS REQUIRED BY GOVERNING AUTHORITIES AND CODES. PROVIDE MATERIALS, ACCESSORIES, AND INSTALLATION PROCEDURES WHICH HAVE BEEN LISTED BY UL OR TESTED IN ACCORDANCE WITH ASTM E119 FOR THE TYPE
OF CONSTRUCTION SHOWN.
3. PROVIDE ALL ACCESSORIES INCLUDING TRACKS, BLOCKING, LINTELS, CLIP ANGLES, STRAP BRACING, SHOES, AND FASTENERS TO PROVIDE A COMPLETE METAL FRAMING SYSTEM.
4. INSTALL HORIZONTAL BRIDGING AS REQUIRED BY STUD DESIGNER. MINIMUM BRIDGING SPACING SHALL BE
4'-0" ON CENTER UNTIL PERMANENT INTERIOR WALL SHEATHING IS INSTALLED.
5. ALL METAL FRAMING COMPONENTS SHALL BE FORMED FROM STRUCTURAL STEEL SHEET CONFORMING TO THE REQUIREMENTS OF ASTM A653, WITH A MINIMUM YIELD STRENGTH OF 33,000 PSI. TRUSS TOP CHORDS
SHALL HAVE A MINIMUM YIELD STRENGTH OF 50,000 PSI.
6. ALL METAL FRAMING COMPONENTS SHALL HAVE A GALVANIZED FINISH COMPLYING WITH ASTM A525 FOR A MINIMUM G60 COATING. FRAMING COMPONENTS SERVING AS BACK-UP FOR MASONRY VENEER EXTERIOR
WALLS SHALL HAVE A MINIMUM G90 GALVANIZED FINISH.
7. ALL METAL FRAMING COMPONENTS SHALL BE CUT SQUARELY FOR ATTACHMENT TO PERPENDICULAR
MEMBERS OR, WHEN REQUIRED, FOR AN ANGULAR FIT TO ABUTTING MEMBERS.
8. SPLICING OF AXIAL LOADED MEMBERS IS NOT PERMITTED.
9. FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS OR WELDING AS STANDARD WITH
MANUFACTURER. SCREWS SHALL BE OF SUFFICIENT SIZE TO INSURE STRENGTH OF THE CONNECTION. ALL WELDS SHALL BE TOUCHED UP WITH A ZINC-RICH PAINT. AT EXTERIOR WALLS THAT ARE PART OF THE BUILDING ENVELOPE, COAT SCREWS WITH BITUMINOUS OR ZINC-RICH PAINT. WIRE TYING OF COMPONENTS IS
NOT PERMITTED.
10. FRAMING COMPONENTS MAY BE PREFABRICATED INTO PANELS PRIOR TO ERECTION. FABRICATE PANELS PLUMB, SQUARE, TRUE TO LINE AND BRACED AGAINST RACKING. PERFORM LIFTING OF PREFABRICATED
PANELS IN A MANNER TO PREVENT DAMAGE OR DISTORTION.
11. INSTALL FRAMING MEMBERS AS PER MANUFACTURER'S DESIGN AND RECOMMENDATIONS.
12. PROVIDE TEMPORARY BRACING, WHEN REQUIRED, UNTIL ERECTION IS COMPLETE.
034100 - PRECAST CONCRETE PANELS
1. PRECAST CONCRETE REINFORCING (INCLUDING REINFORCING REQUIRED FOR LIFTING PURPOSES) SHALL BE PROVIDED BY PRECAST CONCRETE PANEL MANUFACTURER. DESIGN OF THE PRECAST UNITS SHALL BE PERFORMED BY A PROFESSIONAL ENGINEER REGISTERED IN THE PROJECT STATE AND SHALL INCORPORATE ALL OF THE LOADS AS INDICATED IN THE CONTRACT DOCUMENTS AND AS REQUIRED BY APPLICABLE CODES.
2. CONCRETE FOR ALL PRECAST WALL PANELS SHALL BE NORMAL WEIGHT WITH A 28-DAY COMPRESSIVE STRENGTH, f'c = 5,000 PSI.
3. MISCELLANEOUS METAL FOR PRECAST WALL PANEL CONNECTIONS (ANGLES AND PLATES) SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A123, PREPARED, AND FIELD PAINTED AS SPECIFIED. REPAIR
GALVANIZED SURFACES THAT ARE DAMAGED BY WELDING IN ACCORDANCE WITH ASTM A780.
4. PRECAST CONCRETE CONNECTIONS NOT SPECIFICALLY DETAILED SHALL BE DESIGNED FOR THE LOADS INDICATED USING STANDARD CONNECTIONS AS PER THE CONTRACT DOCUMENTS. DESIGN OF PRECAST CONCRETE CONNECTIONS SHALL BE PERFORMED BY A PROFESSIONAL ENGINEER REGISTERED IN THE
PROJECT STATE.
5. ELEMENTS OF PRECAST CONNECTIONS EXPOSED TO THE EFFECTS OF WEATHER AND EXTERIOR CONDITIONS
SHALL BE GALVANIZED IN ACCORDANCE WITH THE SPECIFICATIONS.
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
CHEROKEE COUNTY, GEORGIA
922CM3006
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS SUBMISSION
GEORGIA NATIONAL CEMETERY
CONSTRUCTION DOCUMENTS
FOR PHASE 2
F ile
P at h:
G
P
R O
JE
C
T \S
B U
\E N
G
IN
\3
1\
\S
E N
T \2
1-
-0
1_ T
IT
LE
B
LO
C K
\9
C M
_G -T
T
LB
.D W
G
The LA Group
(518) 587-8100
RVi
(512) 480-0032
Leo A Daly
(402) 391-8111
Aqua Engineering
(970) 372-6104
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Gordon 148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Project No. 003-10230-003
FEBRUARY 28, 2022
BID DOCUMENTS
STRUCTURAL GENERAL NOTES
S-001
JMHAG
TABLE 010000-1 - CODE-SPECIFIED MINIMUM FLOOR LIVE LOADS
OCCUPANCY
UNIFORMLY
DISTRIBUTED
LOAD (PSF)
CONCENTRATED
LOAD * (LBS)
OFFICES 50** 2000
STAIRWAYS, CORRIDORS, LOBBIES, ASSEMBLY AREAS AND ELEVATOR LOBBIES 100 --
TABLE 010000-2 - WIND LOADS *(PSF) FOR COMPONENTS AND CLADDING
SURFACE AREA
EFFECTIVE WIND AREA **
AEFF < 10 SF 10 SF ≤ AEFF < 500 SF AEFF > 500 SF
ROOF INTERIOR
ZONES
TYPICAL, UNO -41.5 LINEAR INTERPOLATION
PERMITTED
-26.0
ROOF END ZONES PER DIAGRAM -54.7 LINEAR INTERPOLATION
PERMITTED
-34.9
ROOF CORNER
ZONES
PER DIAGRAM -74.6 LINEAR INTERPOLATION -34.9
WALL INTERIOR
ZONES
TYPICAL, UNO +23.8/-22.3 LINEAR INTERPOLATION +17.9/-19.9
WALL END
ZONES
PER DIAGRAM -23.8/-31.8 LINEAR INTERPOLATION +17.9/-19.9
TABLE 033000-1 - LAP SPLICE LENGTHS (GRADE 60 BARS, NORMAL WEIGHT CONCRETE)
BAR
SIZE
f'c=3000 psi f'c=3500 psi f'c=4000 psi f'c=4500 psi f'c=5000 psi
TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS
#3 2'-4" 1'-10" 2'-2" 1'-8" 2'-0" 1'-7" 1'-11" 1'-6" 1'-10" 1'-5"
#4 3'-1" 2'-5" 2'-11" 2'-3" 2'-8" 2'-1" 2'-6" 2'-0" 2'-5" 1'-10"
#5 3'-11" 3'-0" 3'-8" 2'-9" 3'-4" 2'-7" 3'-2" 2'-5" 3'-0" 2'-4"
#6 4'-8" 3'-7" 4'-4" 3'-4" 4'-0" 3'-1" 3'-10" 2'-9" 3'-7" 2'-9"
#7 6'-9" 5'-3" 6'-3" 4'-10" 5'-10" 4'-6" 5'-6" 4'-3" 5'-3" 4'-1"
#8 7'-9" 6'-0" 7'-2" 5'-7" 6'-8" 5'-2" 6'-4" 4'-11" 6'-0" 4'-7"
033000 - LAP SPLICE LENGTHS NOTES
1. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OF CONCRETE CAST BELOW BARS.
2. TABULATED VALUES ARE FOR UNCOATED OR ZINC-COATED (GALVANIZED) BARS. FOR EPOXY COATED BARS, MULTIPLY LENGTH BY 1.5.
3. IF CONCRETE COVER IS LESS THAN 1.0 x db OR C-C SPACING IS LESS THAN 3.0 x db, MULTIPLY LENGTH BY 1.5. (db = BAR DIAMETER)
TABLE 042000-1 - LAP SPLICE LENGTHS IN GROUTED CMU (GRADE 60 BARS)
BAR SIZE
BARS CENTERED IN CELL BARS OFFSET IN CELL (1 1/2" MIN. CLR.)
f'm=1,500 psi**** f'm=2,000 psi**** f'm=1,500 psi**** f'm=2,000 psi****
#3 1’-0” 1’-0” 1’-7” 1’-5”
#4 1’-3” 1’-1” 2’-10” 2’-6”
#5* 1’-11” 1’-8” 3’-9” 3’-9”
#6* 3’-7” 3’-1” 4’-6” 4’-6”
042000 SPLICE NOTES
*PERMITTED IN 6” CMU ONLY IF ALL MORTAR FINS ARE REMOVED FROM THE CELL TO BE GROUTED.
ALL MORTAR FINS SHALL BE REMOVED FROM GROUTED CELLS IN 6” CMU WITH #5 OR #6 BARS.
TABLE 033000-2 - STRAIGHT BAR EMBEDMENT LENGTHS (GRADE 60 BARS, NORMAL WEIGHT CONCRETE)
BAR
SIZE
f'c = 3000 psi f'c = 3500 psi f'c = 4000 psi f'c = 4500 psi f'c = 5000 psi
TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS
#3 1'-10" 1'-5" 1'-8" 1'-4" 1'-7" 1'-3" 1'-6" 1'-2" 1'-5" 1'-1"
#4 2'-5" 1'-10" 2'-3" 1'-8" 2'-1" 1'-7" 2'-0" 1'-6" 1'-10" 1'-5"
#5 3'-0" 2'-4" 2'-9" 2'-2" 2'-7" 2'-0" 2'-5" 1'-11" 2'-4" 1'-10"
#6 3'-7" 2'-9" 3'-4" 2'-7" 3'-1" 2'-5" 2'-11" 2'-3" 2'-9" 2'-2"
#7 5'-3" 4'-0" 4'-10" 3'-8" 4'-6" 3'-6" 4'-3" 3'-3" 4'-1" 3'-1"
#8 6'-0" 4'-7" 5'-7" 4'-3" 5'-2" 4'-0" 4'-11" 3'-9" 4'-7" 3'-7"
TABLE 033000-2 - STRAIGHT BAR EMBEDMENT LENGTHS NOTES
1. SEE TABLE 033000-1 FOR LAP SPLICE LENGTH REQUIREMENTS.
2. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OR CONCRETE CAST BELOW BARS.
3. TABULATED VALUES ARE FOR UNCOATED OR ZINC-COATED (GALVANIZED) BARS. FOR EPOXY COATED BARS, MULTIPLY LENGTH BY 1.5.
4. IF CONCRETE COVER IS LESS THAN 1.0 x db OR C-C SPACING IS LESS THAN 3.0 x db, MULTIPLY LENGTH BY 1.5 (db = BAR DIAMETER)
TABLE 033000-3 - STANDARD HOOK EMBEDMENT LENGTHS (GRADE 60 BARS,...
BAR SIZE f'c = 3000 psi f'c = 3500 psi f'c = 4000 psi f'c = 4500 psi f'c = 5000 psi
#3 0'-9" 0'-8" 0'-7" 0'-7" 0'-7"
#4 0'-11" 0'-10" 0'-10" 0'-9" 0'-9"
#5 1'-2" 1'-1" 1'-0" 0'-11" 0'-11"
#6 1'-5" 1'-4" 1'-3" 1'-2" 1'-1"
#7 1'-7" 1'-6" 1'-5" 1'-4" 1'-3"
#8 1'-10" 1'-8" 1'-7" 1'-6" 1'-5"
TABLE 033000-3 - STANDARD HOOK EMBEDMENT NOTES
1. TABLE APPLIES TO STANDARD 90-DEGREE HOOKS AND STANDARD 180-DEGREE HOOKS.
2. SEE DIAGRAM 033000-1. OTHER DETAILS MAY ALSO INDICATE EMBED REQUIREMENTS.
5. TABULATED VALUES ARE FOR UNCOATED OR ZINC-COATED (GALVANIZED) BARS. FOR EPOXY BARS, MULTIPLY LENGTH BY 1.2.
6. IF CONCRETE SIDE COVER (NORMAL TO PLANE OF HOOKS) IS NOT LESS THAN 2 1/2 INCHES, AND FOR 90-DEGREE HOOKS WITH COVER ON THE BAR EXTENSION BEYOND THE HOOK NOT LESS THAN 2 INCHES, THE
LENGTH MAY BE MULTIPLIED BY 0.7.
JACOB KEVIN
ZACH
E-16395
Õ É-Þ
OF
(t28OL 28 À3xlÞ
E9
SB100
E6
SB100
SOG, NOTE 1
EL = 100'-0"
FOUNDATION PLAN NOTES
1. SLAB-ON-GRADE TO BE 4" THICK, REINFORCED WITH 6x6-W2.9xW2.9 WWF. SEE DETAIL
FOR SLAB- ON-GRADE JOINT DETAILS.
2. SEE DETAILS THRU FOR TYPICAL CMU WALL REINFORCING AND GROUTING
INFORMATION.
3. SEE DETAILS ON SHEET SF200 FOR TYPICAL BOND BEAM, MASONRY AND STEEL LINTEL SIZES WHERE
NOT SPECIFICALLY CALLED OUT IN PLANS/DETAILS.
4. REFER TO ARCHITECTURAL DRAWINGS FOR EXTENT OF DEMOLITION NOT SHOWN ON STRUCTURAL
DRAWINGS.
8. GC TO REVIEW EXISTING FOUNDATION DRAWINGS AND CONFIRM ALL FOOTING ELEVATIONS AND
EXTENTS IN FIELD.
/C6 SB100
NEW PARTIALLY GROUTED CMU WALL
REINF W/ #5 AT 48" MAX, TYP U.N.O.
PROVIDE BARS AT CORNER CELLS
AND CELLS ADJACENT TO OPENINGS
EXISTING CMU
WALL TO REMAIN
NEW CMU INFILL
/B6 SB100 /B9 SB100
1 2
X
A
EXISTING HSS8x8
COLUMN TO
REMAIN - VIF, TYP
NEW WALL FOOTING,
SEE DETAILS, TYP
'-8
/8
+/- 27'-2" VIF
F7
SB100
D1
SB100
C9
SB100
EXISTING FOUNDATIONS -
DO NOT DISTURB
E9
SB100E9
SB100
PROVIDE #5 VERT. IN EA. CELL
LEVEL 1
100'-0"
TO FOOTING
98'-8"
2'-4"
1' -0
X
GROUT CAVITY SOLID
BELOW GRADE
STOREFRONT OPNG
W/ WALL BEYOND
BENT BAR (MATCH SIZE
AND SPACING OF CMU
WALL REINFORCEMENT)
VENEER - SEE ARCH
8" CMU
(MATCH EXISTING)
(3) #5xCONT.
#5 AT 24"c/c
E M
B E
D 8"
CENTER VERT BARS
IN CMU CELLS
1'-4" 1 5/8"
1/4" ISO JOINT
w/ FILLER
FULLY GROUT CELLS
BELOW GRADE
C/C SPACING (TYP.)
C/C SPACING (TYP.)
S E
E P
LA
N
S E
E P
LA
N
* 1 1/2" CLR @ INTERIOR WALLS, 2" CLR @ EXTERIOR WALL
ASTM C90 CONCRETE
MASONRY UNITS
HORIZ. LADDER TYPE JOINT
REINFORCING, MAXIMUM 16" c/c
VERTICAL SPACING - #9 GAGE MIN.
FULLY GROUTED
CELL AT EACH
REINF. BAR (TYP.)
LOCATION OF LAP
SPLICE BAR IF
REQUIRED (TYP.)
LOCATION OF LAP
SPLICE BAR IF
REQUIRED (TYP.)
C
LR2"
C
LR2"
E Q
E Q
(T Y
P
5/ 8"
C O
V E
R
(MIN.)
1/2" CLR
(MIN.)
1/2" CLR
(T Y
P
5/ 8"
C O
V E
R
3/8" CONTROL JOINT
S E
E P
LA
N
S
CONTROL JOINTS SPACED AS INDICATED
IN STRUCTURAL GENERAL NOTES AND/OR
AS SHOWN ON PLANS AND ARCH. ELEVATIONS
PREFORMED CONTROL
JOINT GASKET
STOP JOINT REINF.
AT CONTROL JOINT
JOINT AND VERTICAL
REINFORCEMENT AS
REQUIRED
BACKER ROD
AND SEALANT
CONCRETE MASONRY
SASH UNIT
APPROX.
1/2 WALL HEIGHT
MORTAR JOINT
* STEEL ANCHOR @ 16"c/c
FOR 6" & LARGER MASONRY
(ALTERNATE w/HORIZ. JT. REINF.)
C.J.
FILL w/GROUT
1"
24"
(STANDARD LENGTH)
2"
2"
1/ 4"
GALV.
LEVEL 1
100'-0"
TO FOOTING
98'-8"
EXISTING CMU WALL
TO REMAIN
NEW CMU
WALL BEYOND
NEW SLAB-ON-GRADE
EXIST SLAB-ON-
GRADE TO REMAIN
EXIST FOOTING
TO REMAIN
DRILL & EPOXY NEW FOOTING REINF
6" INTO EXIST FOOTING. EPOXY WITH
HILTI HY 200 ADHESIVE
TOP OF NEW FOOTING TO
MATCH TOP OF EXIST
FOOTING, SEE PLAN FOR REINF
'-0
M A
T C
H E
X
IS
T
ROUGHEN EXIST SURFACE
TO 1/4" AMPLITUDE & APPLY
BONDING AGENT
A
DO NOT DISTURB SOIL BELOW
FOOTING OR BELOW THIS LINE
1/4" ISOLATION
JOINT w/ FILLER
"T
"T
"T
"T
"T " 1"
W/ JT SEALER
1/4" EXP JT
(KCJ) KEYED CONSTRUCTION JOINT
A
(C.J.) CONTRACTION JOINT (I.J.) ISOLATION JOINT
PAINT FIRST POUR
WITH BOND
BREAKER
REINFORCING -
SEE STRUCTURAL
GENERAL NOTES
1 x 2 NOMINAL KEY
FREE DRAINING
GRANULAR FILL
VAPOR BARRIER
JOINT WITH SEALER
"T
M
IN
REINFORCING - SEE
STRUCTURAL GENERAL NOTES
(CUT EVERY OTHER
WIRE IF W.W.F. IS USED)
VAPOR
BARRIER
FREE DRAINING
GRANULAR FILL
JOINT FILLER
STRIPS
FACE OF WALL, COLUMN,
FOUNDATION OR OTHER
STRUCTURES
NOTES:
1. SEE PLANS AND/OR SPECIFICATIONS
FOR LOCATION OF CONTROL JOINTS
2. SEE FOUNDATION PLAN
FOR SLAB THICKNESS "T"
B C
TOP OF S.O.G.
EL.=VARIES
(SEE PLANS)
COMPACTED
NATIVE SOIL
REINFORCING -
SEE STRUCTURAL
GENERAL NOTES
COMPACTED
NATIVE SOIL
T Y
P
2" C
LR
LEVEL 1
100'-0"
TO FOOTING
98'-8"
A
BOTTOM COURSE OF
EXISTING CMU WALL MAY BE
ABANDONED OR REMOVED
NEW SLAB-ON-GRADE -
SEE PLAN
EXIST SLAB-ON-
GRADE TO REMAIN
EXIST FOOTING TO
REMAIN. DO NOT DISTURB.
EXISTING HOOKS TO REMAIN,
CUT AS REQ'D AND ABANDON
CMU WALL BEYOND TO
REMAIN, DO NOT DISTURB
(VIF)
DEMO TOP TWO COURSES OF CMU
BELOW EXISTING WINDOW AT NEW
DOOR THRESHOLD.
3/8" COMPRESSIVE
FILLER w/ SEALANT
#3 DOWEL x 1'-0" AT 18"c/c w/ HILTI HY200 ADHESIVE
DO NOT DISTURB SOIL BELOW
FOOTING OR BELOW THIS LINE
4"
LAP AND TAPE VAPOR
BARRIER
PROVIDE CORROSION INHIBITING
EPOXY AT EXPOSED END OF REBAR
LEVEL 1
100'-0"
TO FOOTING
98'-8"
X
2'-4"
1' -0
6"
CMU WALL W/
VENEER BEYOND
8" CMU IN-LINE WITH
WALL BEYOND
NEW SLAB-ON-GRADE, SEE PLAN W/
TURN-DOWN & 2-#4 AT DOORWAY, TYP
PROVIDE ISOLATION JOINT CENTERED
UNDER DOOR PER DETAIL /C6 SB100
#4@12" DOWELS (4 SIDES)
2'-6"
1'-3"
SIDEWALK,
SEE CIVIL
SLOPE TO MATCH CIVIL
DOOR, SEE ARCH
1'-4" (3) #5xCONT.#5 AT 12" c/c
SUPPLIMENTAL 8" CMU BELOW
STOOP (FULLY GROUT)
#5 BENT BAR
5'-0".
1' -6
M
IN
8"
60.00°
#3x1'-0" DOWELS AT 12"c/c
(3) #4xCONT.
6" VOID FORM
STOOP TURN DOWN BEYOND
4"
6x6-W2.9xW2.9 WWF
C
LR
1/
2"
LEVEL 1
100'-0"
TO FOOTING
98'-8"
A
1/4" ISOLATION
JOINT w/ FILLER
EXISTING FOUNDATION
AND 8" CMU WALL
NEW SLAB ON GRADE
EXISTING SLAB ON GRADE
8"
8" CMU INFILL
#…