Attachment 1E - Chiller Plant - 100 Drawings.pdf
PDF 20 MB Posted
- Attached to
- Y1DA--VISN 8 MATOC - Mainland
- Solicitation number
- 36C77624R0131
About this file
This document is a comprehensive set of architectural and engineering drawings for a Design-Build Chiller Replacement project at the Viera VA Outpatient Clinic in Viera, Florida. The project, identified as VA Project #675-18-151, involves demolishing the existing chiller yard, installing new mechanical equipment, constructing a new chiller plant building, and replacing cooling towers and associated systems. The drawings, dated December 20, 2019, include detailed plans for civil, structural, architectural, mechanical, electrical, plumbing, and fire protection aspects of the renovation.
Key project elements include constructing a new chiller plant building with concrete walls and foundations, installing new chillers and cooling towers, implementing a new BAS (Building Automation System), and coordinating work around the existing VA facility operations. The project will require careful phasing, including temporary equipment placement, utility modifications, and coordination with VA personnel. The design team includes LCA Architecture, TLC Engineering Solutions, and Morgan & Associates Consulting Engineers, with Moran Construction as the contractor. The documents are prepared at 100% Construction Documents stage and are fully sprinklered, designed in compliance with the Florida Building Code (6th Edition, 2017).
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FERDINAND STREET - 60' R.O.W.
N
'4
"W o ,1
.0 oS89 11'20"W 1,100.00'
POND
N
'4
"W o
.0
T O
W N
C E
N T
E R
D R
IV
E
' R
.O .W
N89 11'20"Eo 982.00'
R .0
D
'1
A
.5 o
A 8.3
R 95.0
D 6 48
'44 o
K
J
P
N
M
L
UP
EWC
DOWN
1 HRFIRE
1 H R
FIR
E
V V
V
V V
High Voltage Transformer for Mai n faci li ty
650 KV Emrgency generator for Mai n fac ili ty
PV
MRI
Fire hydrant
FDC
11'-1 1_
11'-1 1_
11'-4 1_
11'-4 1_
PROJECT LOCATION - CHILLER BUILDING
PROJECT LOCATION - CANTEEN
VIERA, FL.
VAMC OUTPATIENT CLINIC
GENERAL
ARCHITECTURAL
CIVIL
STRUCTURAL
PLUMBING
FIRE PROTECTION
MECHANICAL
ELECTRICAL
GI001 COVER SHEET
GI002 PHASING PLAN
CD100 DEMOLITION PLAN
CS101 SITE PLAN
CG101 PAVING, GRADING, & DRAINAGE PLAN
CU101 UTILITY PLAN
CJ501 CONSTRUCTION DETAILS
SA001 STRUCTURAL ABBREVIATIONS AND SYMBOLS
SA002 STRUCTURAL NOTES
SA003 BUILDING WIND LOAD DIAGRAM
SD001 DEMOLITION PLAN
SF101 FOUNDATION AND SLAB PLAN
SF102 ROOF FRAMING PLAN
SF103 SCREEN WALL PLAN
SJ501 STRUCTURAL DETAILS
SJ502 STRUCTURAL DETAILS
SJ503 STRUCTURAL DETAILS
AE101 CHILLER BUILDING FLOOR PLAN
AE102 CANTEEN FLOOR PLAN
AE103 CHILLER BUILDING ROOF PLAN
AE104 REFLECTED CEILING PLAN
LS101 LIFE SAFETY PLAN NOTES
AE201 DETAILS, SCHEDULES
AE301 CHILLER BUILDING ELEVATIONS
AE302 CHILLER BUILDING ELEVATIONS
AE401 CHILLER BUILDING SECTIONS
AE402 CHILLER BUILDING WALL SECTIONS, DETAILS
AE403 SECTIONS, DETAILS
FP001 FIRE PROTECTION SYMBOLS, LEGEND, & NOTES
FP100 FIRE PROTECTION SITE PLAN
FP101 CHILLER BUILDING FIRE PROTECTION PLAN
FP102 FREEZER/COOLER FIRE PROTECTION PLAN
FP501 FIRE PROTECTION DETAILS
P-001 PLUMBING SYMBOLS, SCHEDULE, NOTES AND ABBREVIATIONS
P-101 PLUMBING PLANS
P-501 PLUMBING DETAILS AND RISERS
M-001 MECHANICAL LEGEND, NOTES, AND ABBREVIATIONS
MD101 MECHANICAL DEMOLITION PLAN
MD201 FREEZER/COOLER MECHANICAL DEMOLITION PLAN
M-101 CHILLER PLANT MECHANICAL NEW WORK PLAN
M-201 FREEZER/COOLER MECHANICAL NEW WORK PLAN
M-301 MECHANICAL SECTIONS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-701 BAS - MECHANICAL CHW SYSTEM SEQUENCE OF OPERATION
M-702 BAS - CHW PLANT CONTROL DIAGRAM
M-703 BAS - MECHANICAL EQUIPMENT SEQUENCES OF OPERATION
M-704 BAS - MECHANICAL EQUIPMENT SEQUENCES OF OPERATION
M-705 BAS - MECHANICAL EQUIPMENT SEQUENCES OF OPERATION
M-706 BAS - MECHANICAL EQUIPMENT SEQUENCES OF OPERATION
M-707 BAS - CONTROL SYSTEM ARCHITECTURE
M-708 BAS - MECHANICAL CONTROLS ROOF PLAN
E-001 ELECTRICAL SYMBOL LEGEND, AND ABBREVIATIONS
E-002 ELECTRICAL, FIRE ALARM, AND DEMOLITION GENERAL NOTES
ED101 ELECTRICAL PLAN - DEMOLITION
ED601 ELECTRICAL ONE-LINE DIAGRAM - DEMOLITION
EL101 ELECTRICAL PLAN - LIGHTING & LIGHTING FIXTURE SCHEDULE
EP101 ELECTRICAL PLAN - POWER
EP201 ELECTRICAL PLAN - FREEZER/COOLER - POWER
EP501 ELECTRICAL POWER DETAILS
EP601 ELECTRICAL ONE-LINE DIAGRAM
EP701 ELECTRICAL PANEL SCHEDULES
ES101 ELECTRICAL SITE PLAN
ET101 ELECTRICAL PLAN - SYSTEMS
ET501 ELECTRICAL SYSTEMS DETAILS
EY101 ELECTRICAL PLAN - LIGHTNING PROTECTION
EY501 LIGHTNING PROTECTION DETAILS
SHEET #
DWG # SHEET NAME
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
ARCHITECT:
STAMPCONTRACTOR
321 4 5 6 7 8 9 10
STRUCTURAL/MEP:MORAN CONSTRUCTION, INC
113 KING ST
COCOA, FL 32922
(321) 639-5970
CIVIL
MORGAN & ASSOCIATES
CONSULTIING ENGINEERS, INC.
504 N. HARBOR CITY BLVD.
MELBOURNE, FL 32935
(321) 751-6088
C R e v it L o c a l\
V A
V
IE
R A
C H
IL
L
E R
R E
P L A
C E
M E
N T
S
T R
R m a tt .o liv e .r v t
/1 /2
:2
:3
A
M
GI001
COVER SHEET
LCA ARCHITECTURE, INC.
1975 SANSBURY'S WAY, STE 108
WEST PALM BEACH, FL 33411
(561) 493-4787
AA 0003432
TLC ENGINEERING SOLUTIONS, INC.
874 DIXON BLVD.
COCOA, FL 32922
(321) 636-0274
COA 15
DESIGN BUILD REPLACE CHILLERS
VIERA
VIERA OUTPATIENT CLINIC, VIERA, FL, 32940
675-18-151
12-20-2019 CGT BAW
DEPARTMENT OF VETERANS AFFAIRS
VIERA VA OUTPATIENT CLINIC
2900 VETERANS WAY
VIERA, FL
32940
DESIGN BUILD - REPLACE CHILLERS - VIERA
PROJECT #: 675-18-151
100% CONSTRUCTION DOCUMENTS
1" = 100'-0"
KEY SITE PLANLOCATION MAP LIST OF DRAWINGS
Revisions: Date:
D
D
D
D
D
D
D
BFP
.4
.6
49.6'
47.1'
VV V
V V
TOE
T O E
TOE
T O E
T O B
T O B
T O B
T O B T O B
T O B
T O B
T O B
TOB
TOB
TOB
TOB
T O B
TOB
T O E
TOE
TOE
TO
E
SD
W
SS
W W W
FPL TRANSFORMER PAD
METER
PROJECT LOCATION -
CHILLER BUILDING
PROJECT LOCATION -
CANTEEN
VICINITY MAP
8' - 0"
2'
0" 6'
0"
4"X6" PT
WOOD POST
EL. (SEE CIVIL)
T/GRADE
8"Ø CONC
PIER, TYP
4'
0"
4"X6" PT
WOOD POSTS2X4 FRAMING
2x4 FRAMING
MDO PLYWOOD
W/ GRAPHICS AS
REQUIRED BY VA
SPECIALTY SIGN
SP-24.01
ERECT CONSTRUCTION FENCE TO PROVIDE SAFE WORKING AREA FOR EMPLOYEES AND PUBLIC. ESTABLISH OFFICE/STORAGE/LAY DOWN AREA.THE CURRENT GOVERNMENT VEHICLE PARKING AREAS THAT SOUNDS THE EXISTING CHILLER YARD WILL NOT BE AVAILABLE FOR GOVERNMENT VEHICLE OR
PATIENT PARKING DURING THE ENTIRE CONSTRUCTION PHASE.
INSTALL TEMPORARY CHILLERS. AS WITH ALL WORK REQUIRING OUTAGES, THIS WILL BE COORDINATED WITH THE VA WITHIN VA REQUIRED
NOTIFICATION PERIODS.
PER THE RFP WORK ON THE NEW BACNET BAS SYSTEM (BOTH EXISTING ITEMS IDENTIFIED IN THE RFP AND NEW ITEMS) WILL START AT THE BEGINNING
OF THE CONSTRUCTION PHASE.
CONSTRUCT NEW CHILLER PLANT. THIS WORK INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING ITEMS IN SEQUENCE:
A. DEMOLITION OF EXISTING CHILLER YARD / WALL
B. INSTALLATION OF UNDER FOOTING UTILITIES / PATCH FOOTING
C. INSTALLATION OF CONCRETE WALLS / COLUMN FOUNDATIONS
D. ROUGH IN UNDER-SLAB UTILITIES
E. INSTALL SITE UTILITIES
F. PLACE CONCRETE CHILLER PADS AND SLAB-ON-GRADE
G. ERECT STRUCTURAL STEEL
H. INSTALL ROOFING SYSTEM
I. INSTALL DOORS
J. SET NEW CHILLERS, COOLING TOWERS, PUMPS
K. ROUGH IN MECHANICAL / ELECTRICAL SYSTEMS
L. INSULATE MECHANICAL SYSTEMS
M. PAINTING / FINISHES
N. INSTALL COOLING TOWER YARD LOUVER FENCE
O. FINISH MECHANICAL / ELECTRICAL SYSTEMS
DURING THE CONSTRUCTION OF THE CHILLER PLANT BUILDING WORK RELATED TO THE REMOVAL AND REPLACEMENT OF THE CANTEEN COOLER / FREEZER WILL ALSO BE TAKING PLACE. ALL WORK WILL BE COORDINATED WITH THE VA INCLUDING LOCATION OF TEMPORARY COOLER / FREEZER
EQUIPMENT.
THROUGHOUT THE CONSTRUCTION PHASE THE COMMISSIONING AGENT WORK WILL BE ON-GOING
TESTING OF ALL SYSTEMS
TRAINING OF VA PERSONNEL
DEMOLISH OR CHILLER
DEMOBILIZATION
CLOSE OUT DOCUMENTATION
PHASING PLAN NOTES
3'
0" 3'
0" 4"X4" PT
WOOD POST
EL. (SEE CIVIL)
T/GRADE
8"Ø CONC
PIER, TYP
4' - 0"
2x4 FRAMING
4"X4" PT
WOOD POSTS
4'
0"
2x4 FRAMING
MDO PLYWOOD
W/ GRAPHICS AS
REQUIRED BY VA
SPECIALTY SIGN
SP-24.04
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
ARCHITECT:
STAMPCONTRACTOR
321 4 5 6 7 8 9 10
STRUCTURAL/MEP:MORAN CONSTRUCTION, INC
113 KING ST
COCOA, FL 32922
(321) 639-5970
CIVIL
MORGAN & ASSOCIATES
CONSULTIING ENGINEERS, INC.
504 N. HARBOR CITY BLVD.
MELBOURNE, FL 32935
(321) 751-6088
C R e v it L o c a l\
V A
V
IE
R A
C H
IL
L
E R
R E
P L A
C E
M E
N T
S
T R
R m a tt .o liv e .r v t
/1 /2
:2
:3
A
M
GI002
PHASING PLAN AND
CONSTRUCTION SIGNAGELCA ARCHITECTURE, INC.
1975 SANSBURY'S WAY, STE 108
WEST PALM BEACH, FL 33411
(561) 493-4787
AA 0003432
TLC ENGINEERING SOLUTIONS, INC.
874 DIXON BLVD.
COCOA, FL 32922
(321) 636-0274
COA 15
DESIGN BUILD REPLACE CHILLERS
VIERA
VIERA OUTPATIENT CLINIC, VIERA, FL, 32940
675-18-151
11-15-2019 CGT AED
1" = 10'-0"
PHASING PLAN/ CONSTRUCTION SIGNAGE
1/2" = 1'-0"
CONSTRUCTION SIGN
1" = 30'-0"
PHASING PLAN CANTEEN AREA
1/2" = 1'-0"
CONSTRUCTION SAFETY SIGN
NO PARKING
NO PARKING
GENERAL NOTES
1. EXISTING UTILITIES ARE TO BE PROTECTED BY THE CONTRACTOR. ANY UTILITIES DAMAGED BY THIS
CONSTRUCTION WILL BE REPAIRED AT THE CONTRACTORS EXPENSE.
2. CONTRACTOR SHALL NOTIFY UTILITY COMPANIES A MINIMUM OF 48 HOURS IN ADVANCE OF ANY
EXCAVATION INVOLVING THEIR LINES SO THEIR OWNER'S REPRESENTATIVES MAY BE PRESENT PRIOR TO
CONSTRUCTION.
3. CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES IN THE FIELD WITH UTILITY OWNER'S
REPRESENTATIVE PRIOR TO CONSTRUCTION. ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND
PLAN CONDITIONS SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION IMMEDIATELY.
4. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING THE LATEST REVISED AND APPROVED PLANS FROM
THE DESIGN FIRM. ANY QUESTIONS AND OR DESIGN DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
5. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING DIMENSIONS AND SITE CONDITIONS AND REPORT ANY
DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
6. THE CONTRACTOR MUST OBTAIN ALL REQUIRED PERMITS BEFORE THE COMMENCEMENT OF
CONSTRUCTION.
7. THE CONTRACTOR MUST NOTIFY THE ENGINEER IF SOIL OR SUBSURFACE CONDITIONS UNSUITABLE FOR
CONSTRUCTION ARE ENCOUNTERED. ALL EXCAVATED MATERIALS DEEMED UNSUITABLE SHALL BE
REMOVED AND DISPOSED OF BY THE CONTRACTOR AT HIS OWN EXPENSE.
8. ITEMS IN CONFLICT WITH THE CONSTRUCTION OF THE DESIGN SUCH AS EXISTING SIDEWALKS, PAVEMENT, DRAINAGE STRUCTURES, AND EXCESS EXCAVATION ARE TO BE REMOVED BY THE CONTRACTOR. THE
DISPOSAL OF SUCH ITEMS MUST BE DONE IN A LEGAL AND PROPER MANNER AWAY FROM THE JOB SITE.
9. WHEN REFERENCED TO F.D.O.T. REFERS TO FLORIDA DEPARTMENT OF TRANSPORTATION ROADWAY AND
TRAFFIC DESIGN STANDARDS.
10. THE CONTRACTOR SHALL RESTORE ALL AREAS DISTURBED BY THIS CONSTRUCTION TO A CONDITION
EQUAL TO, OR BETTER THAN EXISTING.
11. CONTRACTOR IS RESPONSIBLE TO PROTECT AND/OR REPLACE ANY DISTURBED/REMOVED SURVEY
MONUMENTATION DURING CONSTRUCTION WITHIN THE PROJECT LIMITS/PROPERTY BY A LICENSED
SURVEYOR IN THE STATE OF FLORIDA.
10' 20'0
GRAPHIC SCALE
SCALE: 1" = 10'
HALF SIZE: 1" = 20'
O
R
T
H
107 LF OF CURB & GUTTER
TO BE DEMOLISHED
SAWCUT AND REMOVE
PARKING AREA
HVAC EQUIPMENT TO BE REMOVED
(SEE MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION)
EXISTING CONCRETE BLOCK
SCREEN WALL TO BE
DEMOLISHED TO FOUNDATION
(SEE STRUCTURAL DRAWINGS
FOR ADDITIONAL INFORMATION)
EXISTING ELECTRICAL PANEL
AND CONCRETE SLAB TO BE REMOVED
(SEE ELECTRICAL DRAWINGS
FOR ADDITIONAL INFORMATION)
EXISTING CANOPY
STRUCTURE
TO BE REMOVED
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
FORM
08 -
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
CIVIL ENGINEER / SURVEY
STAMP
CONTRACTOR
321 4 5 6 7 8 9 10
MORAN CONSTRUCTION, INC
113 KING ST
COCOA, FL 32922
(321) 639-5970
DESIGN BUILD REPLACE CHILLERS
VIERA
VIERA OUTPATIENT CLINIC, VIERA, FL, 32940
675-18-151
12-20-2019
Revisions: Date:
&AssociatesMORGANAssociatesMORGAN& Civil Engineers and Land Surveyors - E.B. # 7903 / L.B. #7040
Consulting Engineers, Inc.
Phone (321) 751-6088 Fax (321) 751-6089
504 N. Harbor City Blvd. Melbourne, Fl. 32935
MORGAN-ENGSURV.COM
DEMOLITION PLAN
CD100
AK DD
VICINITY MAP
1. THE CONTRACTOR SHALL DETERMINE LOCATIONS AND INVERTS OF EXISTING UTILITIES AND TAKE
PROTECTIVE MEASURES WHEN NECESSARY PRIOR TO PROCEEDING WITH THE DEMOLITION PLAN.
2. THE CONTRACTOR SHALL PERFORM HIS WORK IN ACCORDANCE WITH REQUIREMENTS OF THE VARIOUS
PERMITS INCLUDED IN THE SPECIFICATIONS. ENVIRONMENTAL CONTROLS SHALL BE USED AT LOCATIONS
DESIGNATED IN THE PLANS AND/OR DESIGNATED BY THE ENGINEER.
3. THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND LOCATION OF UNDERGROUND AND
OTHER UTILITIES IS BASED ON AVAILABLE RECORDS AND SURVEYS BUT IS NOT GUARANTEED TO BE
ACCURATE OR ALL INCLUSIVE. THE CONTRACTOR SHALL MAKE HIS OWN DETERMINATION AS TO THE TYPE
AND LOCATION OF UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE THERETO AND IS RESPONSIBLE FOR
COORDINATING UTILITY RELOCATION WITH PROJECT CONSTRUCTION. PRIOR TO ORDERING DRAINAGE
STRUCTURES, THE CONTRACTOR SHALL DETERMINE IF DRAINAGE/UTILITY CONFLICTS EXIST. INFORMATION
ON CONFLICTS IS TO BE SUBMITTED TO THE OWNER'S REPRESENTATIVE AS SOON AS POSSIBLE AFTER
DISCOVERY FOR RESOLUTION.
4. WHERE NEW PAVEMENT IS CONSTRUCTED ADJACENT OF EXISTING PAVEMENT, THE ASPHALT SHALL BE
SAWCUT AND REMOVED 12 INCHES FROM THE EDGE OF THE TRAVEL LANE TO OFFSET THE ASPHALT/BASE
COURSE JOINT.
5. ALL ASPHALT, SIDEWALK & CURB SAW-CUTS SHALL BE STRAIGHT.
DEMOLITION NOTES:
20' 40'0
GRAPHIC SCALE
SCALE: 1" = 20'
HALF SIZE: 1" = 40'
VICINITY MAP
REMOVE EXISTING OR CHILLER YARD
AutoCAD SHX Text
FPL TRANSFORMER PAD
AutoCAD SHX Text Meter
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Gate Valves
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Gate Valve
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
CONC PAD
AutoCAD SHX Text 28.69
AutoCAD SHX Text 28.72
AutoCAD SHX Text 28.73
AutoCAD SHX Text 28.70
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text
SD
AutoCAD SHX Text
SS
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
BFP
AutoCAD SHX Text W
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text W
AutoCAD SHX Text
DDC
AutoCAD SHX Text 28.69
AutoCAD SHX Text 28.72
AutoCAD SHX Text 28.73
AutoCAD SHX Text 28.70
AutoCAD SHX Text
CLINIC
AutoCAD SHX Text 106,397 S.F.
AutoCAD SHX Text
CONCRETE SIDEWALK
AutoCAD SHX Text
ADA RAMP
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text
SD
AutoCAD SHX Text
SS
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
BFP
AutoCAD SHX Text W
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text W
AutoCAD SHX Text
DDC
AutoCAD SHX Text 28.69
AutoCAD SHX Text 28.72
AutoCAD SHX Text 28.73
AutoCAD SHX Text 28.70
AutoCAD SHX Text
BRESLAY DR
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
BRESLAY DR
AutoCAD SHX Text
PROJECT LOCATION
NO P
ARKIN
G
NO PARKING
10' 20'0
GRAPHIC SCALE
SCALE: 1" = 10'
HALF SIZE: 1" = 20'
NEW
COOLING
TOWERS
68 LF TYPE F CURB
PER FDOT INDEX 520-001
19.9'
30.3'
CONSTRUCT 5'x5'
CONCRETE LANDING
FOR STAIRS
GENERAL NOTES
1. PLEASE REFER TO MECHANICAL / STRUCTURAL PLANS FOR ADDITIONAL INFORMATION ON
THE CHILLER PLANT AREA.
8.5'
CONSTRUCT
PRE-ENGINEERED
LOUVER TYPE FENCE
(TYPICAL)
NEW CHILLER PLANT /
MECHANICAL EQUIPMENT
BUILDING
CONSTRUCT 4" THICK
3/4" GRAVEL CHILLER YARD
GRADE TO DRAIN
30.7'
1.7'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
FORM
08 -
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
CIVIL ENGINEER / SURVEY
STAMP
CONTRACTOR
321 4 5 6 7 8 9 10
MORAN CONSTRUCTION, INC
113 KING ST
COCOA, FL 32922
(321) 639-5970
DESIGN BUILD REPLACE CHILLERS
VIERA
VIERA OUTPATIENT CLINIC, VIERA, FL, 32940
675-18-151
12-20-2019
Revisions: Date:
&AssociatesMORGANAssociatesMORGAN& Civil Engineers and Land Surveyors - E.B. # 7903 / L.B. #7040
Consulting Engineers, Inc.
Phone (321) 751-6088 Fax (321) 751-6089
504 N. Harbor City Blvd. Melbourne, Fl. 32935
MORGAN-ENGSURV.COM
22.0'
SITE PLAN
CS101
AK DD
10.5'
9.9'
DOUBLE GATE WITH
CURB CUT
CONSTRUCT 5'x5'
CONCRETE LANDING
FOR DOOR
2.7'
VICINITY MAP
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
24"W WHITE STOP BAR
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
"STOP"
AutoCAD SHX Text
"GOVERNMENT PARKING ONLY"
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
FPL TRANSFORMER PAD
AutoCAD SHX Text Meter
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Gate Valves
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Gate Valve
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
CONC PAD
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
24"W WHITE STOP BAR
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
24"W WHITE STOP BAR
AutoCAD SHX Text
"PEDESTRIAN CROSSING AHEAD"
AutoCAD SHX Text
"PEDESTRIAN CROSSING"
AutoCAD SHX Text
"STOP"
AutoCAD SHX Text
"GOVERNMENT PARKING ONLY"
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
SWALE
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text
SD
AutoCAD SHX Text
SS
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
BFP
AutoCAD SHX Text W
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text W
AutoCAD SHX Text
DDC
AutoCAD SHX Text 28.69
AutoCAD SHX Text 28.72
AutoCAD SHX Text 28.73
AutoCAD SHX Text 28.70
AutoCAD SHX Text
BRESLAY DR
G
NO PARKING
10' 20'0
GRAPHIC SCALE
SCALE: 1" = 10'
HALF SIZE: 1" = 20'
68 LF TYPE F CURB
PER FDOT INDEX 520-001
GENERAL NOTES
1. PLEASE REFER TO MECHANICAL / STRUCTURAL PLANS FOR ADDITIONAL INFORMATION ON
THE CHILLER PLANT AREA.
MEG
±27.06
MEG
±26.17
NEW CHILLER PLANT /
MECHANICAL EQUIPMENT
BUILDING
F.F.EL.= 28.25
CONSTRUCT 4" THICK
3/4" GRAVEL CHILLER YARD
GRADE TO DRAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
FORM
08 -
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
CIVIL ENGINEER / SURVEY
STAMP
CONTRACTOR
321 4 5 6 7 8 9 10
MORAN CONSTRUCTION, INC
113 KING ST
COCOA, FL 32922
(321) 639-5970
DESIGN BUILD REPLACE CHILLERS
VIERA
VIERA OUTPATIENT CLINIC, VIERA, FL, 32940
675-18-151
12-20-2019
Revisions: Date:
&AssociatesMORGANAssociatesMORGAN& Civil Engineers and Land Surveyors - E.B. # 7903 / L.B. #7040
Consulting Engineers, Inc.
Phone (321) 751-6088 Fax (321) 751-6089
504 N. Harbor City Blvd. Melbourne, Fl. 32935
MORGAN-ENGSURV.COM
PAVING, GRADING &
DRAINAGE PLAN
CG101
AK DD
VICINITY MAP
CJ501
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
24"W WHITE STOP BAR
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
"STOP"
AutoCAD SHX Text
"GOVERNMENT PARKING ONLY"
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
FPL TRANSFORMER PAD
AutoCAD SHX Text Meter
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Gate Valves
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Gate Valve
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
CONC PAD
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
24"W WHITE STOP BAR
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
24"W WHITE STOP BAR
AutoCAD SHX Text
"PEDESTRIAN CROSSING AHEAD"
AutoCAD SHX Text
"PEDESTRIAN CROSSING"
AutoCAD SHX Text
"STOP"
AutoCAD SHX Text
"GOVERNMENT PARKING ONLY"
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
SWALE
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text
SD
AutoCAD SHX Text
SS
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
BFP
AutoCAD SHX Text W
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text W
AutoCAD SHX Text
DDC
AutoCAD SHX Text 28.69
AutoCAD SHX Text 28.72
AutoCAD SHX Text 28.73
AutoCAD SHX Text 28.70
AutoCAD SHX Text
BRESLAY DR
G
NO PARKING
10' 20'0
GRAPHIC SCALE
SCALE: 1" = 10'
HALF SIZE: 1" = 20'
CONSTRUCT 6" DOUBLE
DETECTOR CHECK VALVE
AND FIRE DEPARTMENT
CONNECTION
CONSTRUCT 8"x6" TAPPING
SLEEVE AND VALVE
CONSTRUCT NEW TAPPING SADDLE / VALVE,
2" REDUCED PRESSURE BACKFLOW PREVENTER,
AND 2" WATER SERVICE.
CONNECT TO EXISTING SANITARY
SEWER LATERAL. CONTRACTOR TO
CONFIRM LOCATION/SIZE/INVERT
CONSTRUCT CLEANOUT
(TRAFFIC BEARING)
6" SEWER LATERAL
@ 0.5% MIN.
(PVC SDR 35)
CONSTRUCT
CLEANOUT
EXISTING
UNDERGROUND
ELECTRIC
6" SEWER LATERAL
@ 0.5% MIN.
(PVC SDR 35)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
FORM
08 -
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
CIVIL ENGINEER / SURVEY
STAMP
CONTRACTOR
321 4 5 6 7 8 9 10
MORAN CONSTRUCTION, INC
113 KING ST
COCOA, FL 32922
(321) 639-5970
DESIGN BUILD REPLACE CHILLERS
VIERA
VIERA OUTPATIENT CLINIC, VIERA, FL, 32940
675-18-151
12-20-2019
Revisions: Date:
&AssociatesMORGANAssociatesMORGAN& Civil Engineers and Land Surveyors - E.B. # 7903 / L.B. #7040
Consulting Engineers, Inc.
Phone (321) 751-6088 Fax (321) 751-6089
504 N. Harbor City Blvd. Melbourne, Fl. 32935
MORGAN-ENGSURV.COM
NEW CHILLER PLANT /
MECHANICAL EQUIPMENT
BUILDING
UTILITY PLAN
CU101
AK DD
6" SEWER LATERAL
@ 0.5% MIN.
(PVC SDR 35)
VICINITY MAP
UTILITY GENERAL NOTES:
1. CONTRACTOR IS TO VERIFY ALL EXISTING UTILITIES PRIOR TO
COMMENCEMENT OF CONSTRUCTION.
2. CONTRACTOR SHALL MAINTAIN UNINTERRUPTED UTILITY SERVICE
TO THE PROJECT AREA AT ALL TIMES.
3. ALL DISTURBED AREAS TO BE SODDED. CONTRACTOR SHALL
RESTORE ALL AREAS TO "BETTER THAN EXISTING" CONDITION.
4. THE MINIMUM LENGTH OF PIPE TO BE RESTRAINED ON EACH SIDE
OF THE FITTING SHALL BE AS SHOWN ON THE RESTRAINT TABLE
OR PER MANUFACTURER'S RECOMMENDATIONS, WHICHEVER IS
GREATER. SEE DETAIL ON SHEET CJ501.
5. A CONTINUITY TEST SHALL BE PERFORMED ON THE TRACING WIRE
AT FINAL INSPECTION, TYPICAL FOR POTABLE WATER
DISTRIBUTION.
POTABLE WATER DISTRIBUTION SYSTEM NOTES:
1. SHOP DRAWINGS OF ALL PIPE, VALVES, AND FITTINGS SHALL BE
SUBMITTED TO, REVIEWED, AND APPROVED BY THE ENGINEER OF
RECORD AND VA PRIOR TO ORDERING MATERIALS.
2. PERMANENT ACCESS SHALL BE PROVIDED BY AN UNOBSTRUCTED, 20
FOOT WIDE, ALL WEATHER DRIVING SURFACE CAPABLE OF SUPPORTING A
32-TON EMERGENCY VEHICLE. THE DRIVING SURFACE SHALL BE
MAINTAINED DURING ALL PHASES OF CONSTRUCTION.
3. ALL WATER MAINS TO HAVE A MINIMUM COVER OF 36" UNLESS
OTHERWISE NOTED.
4. ALL WATER MAIN SHALL HAVE RESTRAINED JOINTS. RESTRAINED JOINTS
SHALL BE EBAA IRON, INCLUDING MECHANICAL JOINT SYSTEM.
5. ALL POINTS OF CONNECTION TO THE EXISTING WATER SUPPLY MUST BE
COORDINATED, APPROVED AND SUPERVISED BY THE UTILITY
CONTRACTOR.
CJ501
CJ501
CJ501
CONSTRUCT
CLEANOUT
CJ501
CJ501
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
24"W WHITE STOP BAR
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
"STOP"
AutoCAD SHX Text
"GOVERNMENT PARKING ONLY"
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
FPL TRANSFORMER PAD
AutoCAD SHX Text Meter
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Gate Valves
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Cleanout
AutoCAD SHX Text Gate Valve
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
CONC PAD
AutoCAD SHX Text
DDC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
6"W WHITE STRIPE
AutoCAD SHX Text
24"W WHITE STOP BAR
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
24"W WHITE STOP BAR
AutoCAD SHX Text
"PEDESTRIAN CROSSING AHEAD"
AutoCAD SHX Text
"PEDESTRIAN CROSSING"
AutoCAD SHX Text
"STOP"
AutoCAD SHX Text
"GOVERNMENT PARKING ONLY"
AutoCAD SHX Text
(2)12"W WHITE CROSSWALK STRIPES
AutoCAD SHX Text
SWALE
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text
SD
AutoCAD SHX Text
SS
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
BFP
AutoCAD SHX Text W
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
ELEC
AutoCAD SHX Text W
AutoCAD SHX Text
DDC
AutoCAD SHX Text 28.69
AutoCAD SHX Text 28.72
AutoCAD SHX Text 28.73
AutoCAD SHX Text 28.70
AutoCAD SHX Text
BRESLAY DR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
FORM
08 -
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
CIVIL ENGINEER / SURVEY
STAMP
CONTRACTOR
321 4 5 6 7 8 9 10
MORAN CONSTRUCTION, INC
113 KING ST
COCOA, FL 32922
(321) 639-5970
DESIGN BUILD REPLACE CHILLERS
VIERA
VIERA OUTPATIENT CLINIC, VIERA, FL, 32940
675-18-151
12-20-2019
Revisions: Date:
&AssociatesMORGANAssociatesMORGAN& Civil Engineers and Land Surveyors - E.B. # 7903 / L.B. #7040
Consulting Engineers, Inc.
Phone (321) 751-6088 Fax (321) 751-6089
504 N. Harbor City Blvd. Melbourne, Fl. 32935
MORGAN-ENGSURV.COM
CONSTRUCTION DETAILS
CJ501
AK DD
CLEANOUT DETAIL
TRAFFIC BEARING CLEANOUT DETAIL
DOUBLE CHECK VALVE ASSEMBLY
RESTRAINED PIPE TABLE
TYPE F CURB DETAIL4
WATER SERVICE REDUCED PRESSURE BACKFLOW PREVENTER6
6" DOUBLE CHECK VALVE
ASSEMBLY WITH FORWARD
FLOW CONNECTION AND FIRE
DEPARTMENT CONNECTION
ADJUSTABLE
PIPE SUPPORT
THRUST BLOCK
DUCTILE IRON
FLANGE & SPIGOT
CHECK VALVE
2-1/2"x2-1/2"x4"
FIRE DEPARTMENT
CONNECTION (FDC)
WRAP PIPE 3 TIMES WITH
FELT PRIOR TO POURING
CONCRETE (TYP.)
USE MEGALUGS OR OTHER APPROVED
RESTRAINED JOINT SYSTEM
O.S.& Y. W/ TAMPER
SWITCH (U.L./F.M.)(TYPICAL)
CONCRETE PAD
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NTS
AutoCAD SHX Text
MIN
AutoCAD SHX Text 6"
AutoCAD SHX Text
MIN
AutoCAD SHX Text 4"
AutoCAD SHX Text
30" MAX.
AutoCAD SHX Text
12" MIN.
AutoCAD SHX Text
THE CUSTOMERS SERVICE LINE UNDERGROUND.
AutoCAD SHX Text FROM WATER METER TO THE POINT WHERE THE 90%%d BEND MEETS THE
AutoCAD SHX Text
NOTE "A"
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
BETWEEN PIPE AND CONCRETE
AutoCAD SHX Text
ALL PIPING SHALL BE SLEEVED
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
TEST COCKS
AutoCAD SHX Text
ALL PIPING AND FITTINGS SHALL BE SWEATED COPPER OR THREADED BRASS,
AutoCAD SHX Text
NOTE " A "
AutoCAD SHX Text
3000 PSI, CONCRETE PAD SHALL
AutoCAD SHX Text
BE A MINIMUM OF 2 FEET WIDE
AutoCAD SHX Text
AND CENTERED ON PIPING
AutoCAD SHX Text
BALL VALVES
AutoCAD SHX Text
MIN
AutoCAD SHX Text 6"
AutoCAD SHX Text
ASSEMBLY SHALL BE PRIMED WITH RUST-OLEUM
AutoCAD SHX Text
RUST INHIBITIVE PRIMER # 960 AND PAINTED
AutoCAD SHX Text
WITH RUST-OLEUM INDUSTRIAL ENAMEL # 925
AutoCAD SHX Text
FEDERAL SAFETY BLUE.
NTS
ABBREV ABBREVIATION
ACI AMERICAN CONCRETE INSTITUTE
ADD ADDITIVE
ADDL ADDITIONAL
AFF ABOVE FINISHED FLOOR
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AISI AMERICAN IRON AND STEEL INSTITUTE
ALT ALTERNATE/ALTERNATIVE
ALUM ALUMINUM
ARCH ARCHITECTURE/ARCHITECTURAL
ASTM AMERICAN SOCIETY OF TESTING MATERIALS
AWS AMERICAN WELDING SOCIETY
B/ BOTTOM OF
BCX BOTTOM CHORD EXTENSION
BLDG BUILDING
BLK BLOCK
BM BEAM
BOT BOTTOM
BP BASE PLATE/BEARING PLATE
BRG BEARING
BTWN BETWEEN
C CHANNEL
CB CONCRETE BEAM
CC CONCRETE COLUMN
CF CUBIC FEET (FOOT)
CIP CAST IN PLACE
CJ CONTRACTION JOINT
CL CENTERLINE
CLR CLEAR/CLEARANCE
CM CONCRETE MASONRY
CMU CONCRETE MASONRY UNIT
CO COMPANY
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CONN CONNECTION
CONST CONSTRUCTION
COORD COORDINATE
CSJ CONSTRUCTION JOINT
CTR CENTER
CTRD CENTERED
CY CUBIC YARD
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIST DISTANCE
DL DEAD LOAD
DN DOWN
DWG DRAWING
EA EACH
EE EACH END
EF EACH FACE
EHPA EMERGENCY HURRICANE PROTECTION AREA
EJ EXPANSION JOINT
ELEC ELECTRIC/ELECTRICAL
EL, ELEV ELEVATION
ENGR ENGINEER
EOD EDGE OF DECK
EOR ENGINEER OF RECORD
EQ SP EQUAL SPACED
ES EACH SIDE
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
F FOUNDATION
FD FLOOR DRAIN
FDN FOUNDATION
FF FINISHED FLOOR
FIN FINISH
FIN GR FINISH GRADE
FLR FLOOR
FS FAR SIDE
FT FEET/FOOT
FTG FOOTING
GA GAGE/GAUGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
GEN GENERAL
GL GRID LINE
GS GALVANIZED STEEL
HD HOT DIPPED
HDG HOT DIPPED GALVANIZED
HORIZ HORIZONTAL
HSA HEADED STUD ANCHOR
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
I MOMENT OF INERTIA
ID INSIDE DIAMETER
I.F. INSIDE FACE
IN. INCH
INT INTERIOR
JST JOIST
JT JOINT
K KIP (1000 LB)
KLF KIPS PER LINEAL FOOT
KSI KIPS PER SQUARE INCH
KWY KEYWAY
LB POUND
LGTH LENGTH
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
LSL LAMINATED STRAND LUMBER
LT WT LIGHT WEIGHT
LVL LAMINATED VENEER LUMBER
MATL MATERIAL
MAX MAXIMUM
MB MASONRY BEAM
MC MISCELLANEOUS CHANNEL/MASONRY COLUMN
MECH MECHANICAL
MET METAL
MFR MANUFACTURE/MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MPH MILES PER HOUR
NGVD NATIONAL GEODETIC VERTICAL DATUM
NIC NOT IN CONTRACT
NO. NUMBER
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTERS
OD OUTSIDE DIAMETER
O.F. OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
P/C PRECAST CONCRETE/PILE CAP
P/T POST TENSIONED
PAR PARALLEL
PCB PRECAST CONCRETE BEAM
PCC PRECAST CONCRETE COLUMN
PCF POUNDS PER CUBIC FEET
PEMB PRE-ENGINEERED METAL BUILDING
PEN PENETRATION
P.J. PANEL JOINT CENTERLINE
PL PLATE
PLF POUNDS PER LINEAR FOOT
PLMG PLUMBING
PLY. PLYWOOD
PREFAB PREFABRICATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT PRESSURE TREATED
R/W REINFORCED WITH
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCING
REQD REQUIRED
REV REVISION
RTU ROOF TOP UNIT
SB SOFFIT BEAM
SCHED SCHEDULE
S.F. SQUARE FEET
SF STRIP FOUNDATION
SIM SIMILAR
SPC SPACE/SPACES
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUCT STRUCTURAL
SYM SYMMETRICAL
T/ TOP OF
TB TIE BEAM
T&B TOP AND BOTTOM
TCX TOP CHORD EXTENSION
TDS TURN DOWN SLAB
TE THICKENED EDGE
TEMP TEMPERATURE
TENS TENSION
THD THREAD/THREADED
THK THICK
TOL TOLERANCE
TRANS TRANSVERSE
TS TUBE STEEL
T.S. THICKENED SLAB
TWF THICKENED WALL FOUNDATION
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
VOL VOLUME
W WIDE FLANGE SECTION
W/ WITH
W/O WITHOUT
WD WOOD
WF WALL FOOTING
WP WATERPROOF
W.P. WORKING POINT
WS WELDED STUD
WT WEIGHT/STRUCTURAL TEE SECTION
WWF WELDED WIRE FABRIC
@ AT DESIGNATION
# POUNDS / REBAR SIZE NUMBER
+/- PLUS OR MINUS
L ANGLE
C.L. CENTER LINE
& AND
Sx SECTION MODULUS Ix MOMENT OF INERTIA
STRUCTURAL ABBREVIATIONS
X
X
X
JOIST BEARING ELEVATION
CONCRETE COLUMN BELOW
METAL DECK
STEPPED FOUNDATION
BOLTED JOIST CONNECTION
STRUCTURAL SYMBOLS AND LEGEND
MOMENT CONNECTION
NORTH ARROW
SPAN DIRECTION
SECTION / DETAIL MARK
ELEVATION MARK
RECESS OR STEP IN SLAB
PLAN / DETAIL MARK
PLAN NOTE
COLUMN GRID LINE
COLUMN AND FOUNDATION TYPE
MARKS
SLOPED SURFACE
WALL TYPES
S .F
2'
-0
ROOF JOIST
BEAM
ROOF JOIST
STEP HEIGHTSTEP FOUNDATION
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
NOTE: SYMBOLS AND LEGEND SHOWN ARE
GENERIC AND DO NOT NECESSARILY INDICATE
ACTUAL OCCURRENCES IN THESE DRAWINGS.
CIP CONCRETE WALL
X
SPOT ELEVATION, TYPICALLY TOP
OF ITEM TAGGED (T/WALL,
T/FOUNDATION, ETC)
X'-X"
F6.0
CC-1
X
XXX'-X"
SLOPE
T/
X'-X"
X
X
CAST-IN-PLACE CONCRETE SLAB
CMU WALL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
ARCHITECT:
STAMPCONTRACTOR
321 4 5 6 7 8 9 10
STRUCTURAL/MEP:MORAN CONSTRUCTION, INC
113 KING ST
COCOA, FL 32922
(321) 639-5970
CIVIL
MORGAN & ASSOCIATES
CONSULTIING ENGINEERS, INC.
504 N. HARBOR CITY BLVD.
MELBOURNE, FL 32935
(321) 751-6088
C R e v it L o c a l\
V A
V
IE
R A
C H
IL
L
E R
R E
P L A
C E
M E
N T
S
T R
R m a tt .o liv e .r v t
/1 /2
:2
:0
A
M
SA001
STRUCTURAL ABBREVIATIONS AND
SYMBOLSLCA ARCHITECTURE, INC.
1975 SANSBURY'S WAY, STE 108
WEST PALM BEACH, FL 33411
(561) 493-4787
TLC ENGINEERING SOLUTIONS, INC.
874 DIXON BLVD.
COCOA, FL 32922
(321) 636-0274
COA 15
DESIGN BUILD REPLACE CHILLERS
VIERA
VIERA OUTPATIENT CLINIC, VIERA, FL, 32940
675-18-151
11-15-2019 CGT BAW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
ARCHITECT:
STAMPCONTRACTOR
321 4 5 6 7 8 9 10
STRUCTURAL/MEP:MORAN CONSTRUCTION, INC
113 KING ST
COCOA, FL 32922
(321) 639-5970
CIVIL
MORGAN & ASSOCIATES
CONSULTIING ENGINEERS, INC.
504 N. HARBOR CITY BLVD.
MELBOURNE, FL 32935
(321) 751-6088
C R e v it L o c a l\
V A
V
IE
R A
C H
IL
L
E R
R E
P L A
C E
M E
N T
S
T R
R m a tt .o liv e .r v t
/1 /2
:2
:0
A
M
SA002
STRUCTURAL NOTES
LCA ARCHITECTURE, INC.
1975 SANSBURY'S WAY, STE 108
WEST PALM BEACH, FL 33411
(561) 493-4787
TLC ENGINEERING SOLUTIONS, INC.
874 DIXON BLVD.
COCOA, FL 32922
(321) 636-0274
COA 15
DESIGN BUILD REPLACE CHILLERS
VIERA
VIERA OUTPATIENT CLINIC, VIERA, FL, 32940
675-18-151
11-15-2019 CGT BAW
15. THE USE OF REPRODUCTIONS OF THESE CONTRACT DOCUMENTS AND USE OF CAD FILES BY ANY CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR OR MATERIAL SUPPLIER IN LIEU OF PREPARATION OF SHOP DRAWINGS SIGNIFY HIS ACCEPTANCE OF ALL INFORMATION SHOWN HEREON AS CORRECT, AND OBLIGATES HIMSELF TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE TO
ANY ERRORS THAT MAY OCCUR HEREON.
14. FINISH FLOOR ELEVATION (FIRST FLOOR) OF 0'-0" IS USED AS A REFERENCE ELEVATION. CIVIL EL= 28.25'
13. NO PROVISIONS HAVE BEEN MADE FOR VERTICAL OR HORIZONTAL EXPANSION EXCEPT AS SHOWN ON CONTRACT DOCUMENTS.
12. IN THE PROFESSIONAL OPINION OF TLC ENGINEERING SOLUTIONS, INC. THE STRUCTURAL CONTRACT DOCUMENTS FOR THIS PROJECT HAVE BEEN PREPARED IN ACCORDANCE WITH THE DESIGN CRITERIA AS SET FORTH IN THE FLORIDA BUILDING CODE (FBC) 6th EDITION (2017).
11. STRUCTURAL ENGINEER OF RECORD IS NOT RESPONSIBLE FOR THE DESIGN OF STEEL STAIRS, HANDRAILS, CURTAIN WALL/WINDOW WALL SYSTEMS, COLD-FORMED STEEL FRAMING, OR OTHER SYSTEMS NOT SHOWN IN THE STRUCTURAL DOCUMENTS. SUCH SYSTEMS SHALL BE DESIGNED, FURNISHED, AND INSTALLED AS REQUIRED BY OTHER PORTIONS OF THE CONTRACT DOCUMENTS.
10. PERIODIC SITE OBSERVATION BY FIELD REPRESENTATIVES OF TLC ENGINEERING SOLUTIONS, INC. IS SOLELY FOR THE PURPOSE OF DETERMINING IF THE WORK OF THE CONTRACTOR IS PROCEEDING IN GENERAL ACCORDANCE WITH THE STRUCTURAL CONTRACT DOCUMENTS. THIS LIMITED SITE OBSERVATION SHALL NOT BE CONSTRUED AS EXHAUSTIVE OR CONTINUOUS TO CHECK THE QUALITY
OR QUANTITY OF THE WORK.
9. THE STRUCTURAL ENGINEER'S OBLIGATIONS TO REVIEW SHOP DRAWINGS AND OTHER SUBMITTALS AND TO RETURN THEM IN A TIMELY MANNER ARE CONDITIONED UPON THE PRIOR REVIEW AND APPROVAL OF THE SHOP DRAWINGS OR SUBMITTALS BY THE CONTRACTOR AS REQUIRED IN THE CONSTRUCTION CONTRACT AND THE CONTRACTOR'S SUBMITTAL OF THE SHOP DRAWINGS AND OTHER SUBMITTALS IN ACCORDANCE WITH A WRITTEN SCHEDULE DISTRIBUTED IN ADVANCE TO THE ENGINEER IDENTIFYING THE
DATES FOR THE SUBMITTAL OF THE VARIOUS SHOP DRAWINGS AND SUBMITTALS.
8. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, AND DO NOT INDICATE THE METHOD OR MEANS OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES, SEQUENCE AND SAFETY. THE ENGINEER DOES NOT HAVE CONTROL OR CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, FOR THE ACTS OR OMISSION OF THE CONTRACTOR, SUBCONTRACTOR OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE
OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
7. THE GENERAL CONTRACTOR SHALL COMPARE THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, CIVIL AND STRUCTURAL DRAWINGS AND REPORT ANY DISCREPANCIES BETWEEN EACH SET OF DRAWINGS AND WITHIN EACH SET OF DRAWINGS TO THE ARCHITECT AND ENGINEER OF RECORD PRIOR TO THE FABRICATION AND INSTALLATION OF ANY STRUCTURAL MEMBERS.
6. DETAILS LABELED "TYPICAL DETAILS" ON THE DRAWINGS SHALL APPLY TO ALL SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. THE APPLICABILITY OF THE DETAIL TO ITS LOCATION ON THE DRAWINGS CAN BE DETERMINED BY THE TITLE OF DETAIL. SUCH DETAILS SHALL APPLY WHETHER OR NOT THEY ARE REFERENCED AT EACH LOCATION. QUESTIONS REGARDING APPLICABILITY OF TYPICAL DETAILS SHALL BE DETERMINED BY THE ENGINEER OF RECORD.
5. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS
OR TIEDOWNS.
4. DO NOT SCALE DRAWINGS.
3. NO STRUCTURAL MEMBER OR COMPONENT SHALL BE CUT, NOTCHED, OR OTHERWISE ALTERED UNLESS APPROVED IN WRITING BY THE ENGINEER OF RECORD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL COSTS INCURRED BY THE ENGINEER OF
RECORD FOR REVIEW OF ANY SUCH DEVIATIONS.
2. DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
ENGINEER OF RECORD BEFORE PROCEEDING WITH THE AFFECTED PART OF THE WORK.
1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH PROJECT SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR OPENINGS, DEPRESSIONS, EQUIPMENT WEIGHTS AND
LOCATIONS, EMBEDDED ITEMS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS.
GENERAL NOTES
SEISMIC IMPORTANCE FACTOR 1.50
SEISMIC DESIGN CATEGORY A
SEISMIC USE GROUP III
SITE CLASSIFICATION D
SPECTRAL RESPONSE ACCELERATION, 1.0 SECOND DURATION (S1) 0.032
SPECTRAL RESPONSE ACCELERATION, SHORT DURATION (Ss) 0.057
2.4 SEISMIC LOADS: PER FLORIDA BUILDING CODE, SECTION 1610.
EXPOSURE C
RISK CATEGORY IV
NOMINAL DESIGN WIND SPEED, Vasd 122 MPH (3 SEC. GUST)
ULTIMATE DESIGN WIND SPEED, Vult 157 MPH (3 SEC. GUST)
SEE SHEET S1.3 FOR COMPONENTS AND CLADDING PRESSURES
2.3 WIND LOADS: PER FLORIDA BUILDING CODE, SECTION 1609.
FLOOR (MECH/ELECTRICAL ROOM) 150 PSF
ROOF 20 PSF
2.2 LIVE LOADS
M/E/P LOADS 15 PSF
ROOF STRUCTURE 15 PSF
2.1 DEAD LOADS
2. THE FOLLOWING SUPERIMPOSED LOADINGS HAVE BEEN UTILIZED:
1. THE STRUCTURAL SYSTEM FOR THIS BUILDING HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, 6th EDITION
(2017), AND AS SUPPLEMENTED BY LOCAL AMENDMENTS.
DESIGN LOADS
2. RFI RESPONSES ARE NOT INTENDED TO AUTHORIZE ANY INCREASE IN CONSTRUCTION COST, SCHEDULE OR TIME EXTENSIONS, OR CONSTRUCTION IN CONFLICT WITH ANY APPLICABLE CODES OR SPECIFIED DESIGN STANDARDS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGN TEAM IMMEDIATELY OF ANY PERCEIVED SCOPE, SCHEDULE, OR COST IMPACTS OR ADJUSTMENTS. IF CONTRACTOR REQUESTS ANY ADDITIONAL COST, INCREASE IN SCHEDULE OR ADJUSTMENT IN SCOPE, THE CONTRACTOR SHALL NOT PROCEED WITH ADDITIONAL WORK UNTIL APPROVED IN WRITING BY THE CONSTRUCTION ADMINISTRATOR.
1. RFI SHALL ORIGINATE WITH CONTRACTOR AND SHALL BE SUBMITTED IN THE FORM SPECIFIED WITHIN CONTRACT DOCUMENTS. RFI
SHALL BE SUBMITTED IN A PROMPT MANNER AS TO AVOID DELAYS IN CONTRACTORS WORK.
REQUEST FOR INTERPRETATION (RFI)
3. CHANGES AND ADDITIONS MADE ON RE-SUBMITTALS SHALL BE CLEARLY FLAGGED AND NOTED. THE PURPOSE OF THE RE-SUBMITTALS SHALL BE CLEARLY NOTED ON THE LETTER OF TRANSMITTAL. ARCHITECT/ENGINEER OF RECORD REVIEW WILL BE
LIMITED TO THOSE ITEMS CAUSING THE RE-SUBMITTAL.
2. SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR AND MARKED "APPROVED" PRIOR TO SUBMITTAL TO THE ARCHITECT/ENGINEER. NON-CONFORMING DRAWING SUBMITTALS WILL BE RETURNED WITHOUT REVIEW.
1. SHOP DRAWINGS SHALL ADEQUATELY DEPICT THE STRUCTURAL ELEMENTS AND CONNECTIONS SHOWN ON THE CONTRACT DOCUMENTS. SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. REVIEW OF SUBMITTALS AND SHOP DRAWINGS DOES NOT RELIEVE THE CONTRACTOR OF FULL RESPONSIBILITY FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF THE
SHOP DRAWINGS.
SHOP DRAWING REVIEW
8. SUBMITTALS NOT MEETING THE ABOVE CRITERIA WILL NOT BE REVIEWED AND WILL BE RETURNED.
D. THAT THE CONFIGURATION SET FORTH IN THE STRUCTURAL SUBMITTALS IS CONSISTENT WITH THE CONTRACT DOCUMENTS. NO
DETAILED CHECK OF DIMENSIONS OR QUANTITIES WILL BE MADE.
C. THAT THE DELEGATED ENGINEER HAS UNDERSTOOD THE DESIGN INTENT AND HAS USED THE SPECIFIED STRUCTURAL CRITERIA.
NO DETAILED CHECK OF CALCULATIONS WILL BE MADE.
B. THAT THE STRUCTURAL SUBMITTALS HAVE BEEN SIGNED AND SEALED BY THE DELEGATED ENGINEER.
A. THAT THE SPECIFIED STRUCTURAL SUBMITTALS HAVE BEEN FURNISHED.
7. REVIEW BY THE STRUCTURAL ENGINEER OF RECORD OF SUBMITTALS IS LIMITED TO VERIFYING THE FOLLOWING:
6. CATALOG INFORMATION ON STANDARD PRODUCTS DOES NOT REQUIRE THE SEAL OF A DELEGATED ENGINEER.
5. DRAWINGS PREPARED SOLELY TO SERVE AS A GUIDE FOR FABRICATION AND INSTALLATION (SUCH AS REINFORCING STEEL SHOP DRAWINGS OR STRUCTURAL STEEL ERECTION DRAWINGS) AND REQUIRING NO ENGINEERING, DO NOT REQUIRE THE SEAL OF A
DELEGATED ENGINEER.
4. SHOP DRAWINGS AND CALCULATIONS SHALL BE SIGNED AND SEALED BY AN ENGINEER REGISTERED IN THE STATE OF FLORIDA (IN WHICH THE PROJECT RESIDES). COMPUTER PRINTOUTS ARE AN ACCEPTABLE SUBSTITUTE FOR MANUAL COMPUTATIONS PROVIDED THEY ARE ACCOMPANIED BY SUFFICIENT DESCRIPTIVE INFORMATION TO PERMIT THEIR PROPER EVALUATION. SUCH DESCRIPTIVE INFORMATION SHALL BE SIGNED AND SEALED BY AN ENGINEER REGISTERED IN THE STATE OF FLORIDA (IN WHICH THE PROJECT RESIDES) AS AN INDICATION THAT HE/SHE HAS ACCEPTED RESPONSIBILITY FOR THE RESULTS. THE STRUCTURAL ENGINEER WILL
RETAIN ONE SIGNED AND SEALED SET FOR THEIR RECORDS.
3. SHOP DRAWINGS AND CALCULATIONS SHALL BE PREPARED UNDER THE DIRECT SUPERVISION AND CONTROL OF THE DELEGATED
ENGINEER.
2. SUBMITTALS SHALL CLEARLY IDENTIFY THE SPECIFIC PROJECT AND APPLICABLE CODES, LIST THE DESIGN CRITERIA, AND SHOW ALL DETAILS AND DRAWINGS NECESSARY FOR PROPER FABRICATION AND INSTALLATION. SHOP DRAWINGS AND CALCULATIONS SHALL
IDENTIFY SPECIFIC PRODUCT UTILIZED. GENERIC PRODUCTS WILL NOT BE ACCEPTED.
D. FORMWORK AND TEMPORARY SHORING
C. TEMPORARY WALL BRACING
B. STRUCTURAL STEEL CONNECTIONS REQUIRING ENGINEERING
A. OPEN WEB STEEL JOISTS
1. THE FOLLOWING SYSTEMS AND COMPONENTS AS A MINIMUM REQUIRE FABRICATION AND ERECTION DRAWINGS PREPARED BY A
DELEGATED ENGINEER:
SHOP DRAWINGS FOR SPECIALTY ENGINEERED PRODUCTS
3. MANUFACTURER'S LITERATURE. SUBMIT TWO COPIES OF MANUFACTURER'S LITERATURE FOR ALL MATERIALS AND PRODUCTS USED IN
CONSTRUCTION ON THE PROJECT.
J. METAL ROOF DECK
I. OPEN WEB STEEL JOISTS (D)
H. FORMWORK AND TEMPORARY SHORING (D)
G. CHEMICAL (ADHESIVE) ANCHORS (#)
F. MECHANICAL ANCHORS (#)
E. TEMPORARY WALL BRACING (D)
D. CONCRETE MIX DESIGNS
C. FORMWORK, SHORING, RESHORING (D,#)
B. REINFORCING STEEL
A. STRUCTURAL STEEL (D)
• ITEMS MARKED (#) SHALL BE SUBMITTED FOR ENGINEERS RECORD ONLY.
• ITEMS MARKED (D) SHALL HAVE SHOP DRAWINGS SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF
FLORIDA.
2. THE GENERAL CONTRACTOR SHALL SUBMIT FOR ENGINEER REVIEW SHOP DRAWINGS FOR THE FOLLOWING ITEMS:
1. ALL SHOP DRAWINGS MUST BE REVIEWED AND STAMPED APPROVED BY THE GENERAL CONTRACTOR PRIOR TO SUBMITTAL.
SUBMITTALS
8. REMOVE COMPLETELY FROM THE SITE AND LEGALLY DISPOSE ALL DEBRIS GENERATED BY THE DEMOLITION WORK AS THE WORK PROGRESSES. STOCKPILING OF DEBRIS AND BURNING OF DEBRIS ON THE PREMISES IS STRICTLY PROHIBITED.
7. BEFORE DEMOLISHING ANY STRUCTURAL ELEMENT, INSTALL ALL REQUIRED TEMPORARY AND/OR PERMANENT BRACING AND
SUPPORTS.
C. FILL THE CAVITY FLUSH WITH A HIGH MODULUS GEL EPOXY. SEE SPECIFICATION FOR ACCEPTED MANUFACTURERS.
B. CUT OFF REINFORCING STEEL NOT LESS THAN 3/4" BELOW THE CONCRETE SURFACE.
A. CHIP CONCRETE FROM AROUND THE STEEL TO A DEPTH OF 1".
6. AT ALL LOCATIONS WHERE THE DEMOLITION OF A CONCRETE MEMBER LEAVES THE ENDS OF REINFORCING STEEL EXPOSED, PROVIDE
THE FOLLOWING:
5. AT ALL LOCATIONS WHERE NEW CONSTRUCTION WILL INTERFACE WITH EXISTING ELEMENTS, CUT THROUGH EXISTING STRUCTURE IN
STRAIGHT AND TRUE LINES TO INSURE A NEAT INTERFACE.
4. THE CONTRACTOR IS REQUIRED TO COORDINATE WITH OWNER FOR THE TEMPORARY SUSPENSION OF USE OF ANY UTILITY SYSTEM, A
MINIMUM OF 3 DAYS PRIOR TO COMMENCING WORK.
3. THE CONTRACTOR IS REQUIRED TO PERFORM HIS WORK IN A MANNER, WHICH WILL NOT CONFLICT WITH ANY OPERATION, WHICH IS TO REMAIN FUNCTIONAL DURING THE COURSE OF THE PROJECT, UNTIL SUCH OPERATION IS SCHEDULED TO BE SHUT DOWN.
2. THE CONTRACTOR IS REQUIRED TO COORDINATE WITH THE OWNER FOR THE TEMPORARY SUSPENSION OF USE OF ANY FACILITY OR PORTION THEREOF, AND THE ASSOCIATED BARRICADING REQUIREMENTS WITHIN A MINIMUM OF 7 DAYS PRIOR TO COMMENCING
WORK.
1. THE CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY SCAFFOLDING, PLATFORMS, BARRICADES, RAILINGS, SCREENING, ETC.
NECESSARY TO PROTECT EXISTING FACILITIES, STRUCTURES AND THE PUBLIC DURING DEMOLITION AND ERECTION OF THE NEW CONSTRUCTION, AS WELL AS FOR JOB SAFETY. JOB SAFETY, CONSTRUCTION AND DEMOLITION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONS TO MINIMIZE VIBRATION, NOISE, DUST AND DEBRIS IN ALL AREAS ADJACENT TO AREAS OF DEMOLITION.
DEMOLITION NOTES
2. WORK SHOWN ON THESE DRAWINGS ASSUMES THAT THE ORIGINAL CONSTRUCTION WAS PERFORMED IN ACCORDANCE WITH THE ABOVE INDICATED ORIGINAL DRAWINGS INCLUDING (BUT NOT LIMITED TO) DIMENSIONS, ELEVATIONS, MEMBER SIZES, MATERIALS, DETAILS, ETC. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE CONDITIONS RELATING TO THE EXISTING STRUCTURE AND TO NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS.
DATED: APRIL 05, 2011
ENTITLED: VIERA VA ROOF/HVAC RENOVATION
PREPARED BY: CAPE DESIGN ENGINEERING Co.
1. INFORMATION SHOWN FOR THE EXISTING STRUCTURE ON THESE DRAWINGS WAS TAKEN FROM THE DRAWINGS THAT WERE PREPARED
FOR:
EXISTING STRUCTURE
2. DESIGN, ERECTION AND REMOVAL OF ALL FORMWORK, SHORES AND RESHORES SHALL MEET THE REQUIREMENTS SET FORTH IN ACI
STANDARDS 347 AND 301.
1. NO STRUCTURAL CONCRETE SHALL BE STRIPPED UNTIL IT HAS REACHED AT LEAST TWO-THIRDS OF THE 28-DAY DESIGN STRENGTH.
FORMWORK AND SHORING
2. ALTERNATE OR ADDED CONSTRUCTION JOINT LOCATIONS ARE ACCEPTABLE ONLY AS A CHANGE ORDER, WHICH WILL INCLUDE ENGINEERING CHARGES BY THE ENGINEER OF RECORD FOR REDESIGN OF THE STRUCTURE, SHORING, ETC.
1. ANY DEVIATION OR ADDITION OF CONSTRUCTION JOINTS FROM THAT SHOWN ON THE DRAWINGS MUST BE REVIEWED AND APPROVED
IN WRITING BY THE ENGINEER OF RECORD.
CONSTRUCTION JOINTS
11. CONCRETE SLABS ON GRADE SHALL BE REINFORCED WITH #3 @ 10" O.C. EACH WAY AT MID-DEPTH OF SLAB.
10. CONCRETE DESIGN MIX SUBMITTALS SHALL INCLUDE TESTED, STATISTICAL BACK-UP DATA AS PER CHAPTER 5 OF ACI 318.
9. CONDUITS, PIPES AND SLEEVES SHALL BE PLACED AND SPACED IN ACCORDANCE WITH ACI 318, 6.3.
8. CONCRETE MIX DESIGNS SHALL INCLUDE A WRITTEN DESCRIPTION INDICATING WHERE EACH PARTICULAR MIX IS TO BE PLACED WITHIN
THE STRUCTURE.
7. CALCIUM CHLORIDES SHALL NOT BE UTILIZED; OTHER ADMIXTURES MAY BE USED ONLY WITH THE APPROVAL OF THE ENGINEER.
6. SLABS SHALL BE CURED USING A DISSIPATING CURING COMPOUND MEETING ASTM STANDARD C309 TYPE 1-CLASS D AND SHALL HAVE A FUGITIVE DYE. THE COMPOUND SHALL BE PLACED AS SOON AS THE FINISHING IS COMPLETED OR AS SOON AS THE WATER HAS LEFT THE UNFINISHED CONCRETE. SCUFFED OR BROKEN AREAS IN THE CURING MEMBRANE SHALL BE RECOATED DAILY.
5. THE MAXIMUM TIME ALLOWED FROM THE TIME THE MIXING WATER IS ADDED UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED ONE AND ONE HALF (1-1/2) HOURS. IF FOR ANY REASON THERE IS A LONGER DELAY THAN THAT STATED ABOVE, THE CONCRETE SHALL BE DISCARDED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING LAB TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE
CONTRACTOR OF ANY NONCOMPLIANCE WITH THE ABOVE.
4. CONCRETE SHALL COMPLY WITH THE REQUIREMENTS OF ASTM STANDARD C94 FOR MEASURING, MIXING, TRANSPORTING, ETC.
CONCRETE TICKETS SHALL BE TIME STAMPED WHEN CONCRETE IS BATCHED.
3. SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CYLINDER OR LAB TESTS FOR REVIEW PRIOR TO USE. MIX SHALL BE UNIQUELY IDENTIFIED BY MIX NUMBER OR OTHER POSITIVE IDENTIFICATION. MIX SHALL MEET THE REQUIREMENTS OF ASTM C33 FOR COARSE
AGGREGATE.
2. CONCRETE SHALL BE PLACED AND CURED ACCORDING TO ACI STANDARDS AND SPECIFICATIONS.
CONCRETE WALLS 4000 PSI 4-6" 3/4" 0.48
SLABS-ON-GRADE 4000 PSI 4-6" 3/4" 0.50
FOUNDATIONS 3000 PSI 4-6" 1" 0.50
CONCRETE STRUCTURE TYPE
COMPRESSIVE
STRENGTH
SLUMP
MAXIMUM
AGGREGATE
MAXIMUM W/C RATIO
1. SHALL BE PER AN APPROVED MIX DESIGN PROPORTIONED TO ACHIEVE A STRENGTH AT 28 DAYS AS LISTED BELOW WITH A PLASTIC AND
WORKABLE MIX:
CONCRETE
9. WHERE HOOKS ARE SHOWN ON THE PLANS OR DETAILS, HOOKS SHALL BE DETAILED TO EXTEND DEEP ENOUGH INTO SUPPORTING STRUCTURE TO DEVELOP THE FULL STRENGTH OF THE HOOKED BAR. PROVIDE ADDITIONAL TIES OR STIRRUPS IN SUPPORTING STRUCTURE AS REQUIRED TO SATISFY ACI 318 HOOK DEVELOPMENT, CONFINEMENT, AND ANCHORAGE CRITERIA.
8. AT CHANGES IN DIRECTION OF CONCRETE WALLS, PROVIDE CORNER BARS OF SAME SIZE AND SPACING AS HORIZONTAL STEEL.
WHERE "T" IS DEPTH OF CONCRETE UNDER BARS AND "Db" IS BAR DIAMETER.
UTILIZE CLASS "B" SPLICE FOR ALL SPLICES, U.N.O. ON PLANS OR DETAILS.
#7 OR MORE 81 Db 79 Db 72 Db
T>12" #6 OR LESS 74 Db 65 Db 57 Db
#7 OR MORE 71 Db 61 Db 55 Db
T<12" #6 OR LESS 57 Db 49 Db 44 Db
BAR SIZE 3000 PSI 4000 PSI 5000 PSI
7. LENGTH OF LAP SPLICES AND BAR EMBEDMENT SHALL BE AS SHOWN IN TABLE, UNLESS OTHERWISE NOTED:
6. PROVIDE DOWELS INTO FOOTINGS. TO MATCH VERTICAL BARS WITH CLASS B TENSION LAP SPLICES, U.N.O.
5. WHERE REINFORCING IS SHOWN CONTINUOUS, SPLICE BOTTOM BARS OVER SUPPORTS AND TOP BARS AT CENTER OF SPAN. ALL OTHER LAP SPLICES SHALL BE IN ACCORDANCE WITH SPLICE TABLES AND DETAILS SHOWN ON DRAWINGS.
4. PROVIDE STANDARD HOOKS AT DISCONTINUOUS ENDS OF…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .