636A8-22-001_Asb-LCP Report.pdf

PDF 6 MB Posted

Attached to
PN: 636A8-22-001, Reno 6th Floor Clinical Support (IC)
Solicitation number
36C26326B0025
Issued by

About this file

This is a Limited Asbestos and Lead-Containing Paint Survey Report for a federal renovation project at the Iowa City VA Health Care System.

The survey was conducted on November 16-17, 2022, by Terracon Consultants, Inc. (licensed asbestos inspectors Ian Bootsmiller and Alex Davis) on the 6th floor of Building 1 at 604 Highway 6 West, Iowa City, Iowa 52246, in anticipation of approximately 22,500 square feet of renovation work. The survey identified asbestos-containing materials (ACM) in multiple locations requiring abatement prior to renovation. Confirmed ACMs include: thermal systems insulation (TSI) with white and grey mudded joints (10-15% Amosite, 30-75% Chrysotile); cloth-wrapped corrugated pipe insulation (75% Chrysotile); 12"x12" off-white floor tiles with grey streaks and black adhesive (4-7% Chrysotile); 12"x12" white floor tiles with tan streaks and black adhesive (4-5% Chrysotile); black adhesive associated with 12"x12" tan floor tiles (4-6% Chrysotile); and TSI white magnesia pre-formed pipe insulation (35-40% Amosite, 5-10% Chrysotile). Total estimated quantities include approximately 3,150 square feet of floor tile, 85 linear feet of pipe insulation, and 25 square feet of mudded joint insulation. The lead-containing paint survey identified one sample at 0.5% by weight (meeting EPA definition of lead-based paint) in room 6E230 on plaster walls, with three additional samples containing lead below the LBP threshold. The report recommends hiring a qualified asbestos abatement contractor compliant with NESHAP and OSHA regulations, notifying the Iowa Department of Natural Resources 10 business days prior to abatement, and completing a supplemental inspection once spaces are vacated to assess assumed but unsampled ACMs in inaccessible areas.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Limited Asbestos and

Lead-Containing Paint

Survey Report Project No. 636A8-22-001 Renovate 6th

Floor for Clinical Unit

Iowa City VA Health Care System

604 Highway 6 West

Iowa City, Iowa 52246

December 12, 2022 | Report Number: 06227130

Prepared for:

Bancroft Architects + Engineers

700 Nicholas Boulevard, Suite 300

Elk Grove Village, Illinois 60007

2640 12th Street SW

Cedar Rapids, Iowa 52404

P (319) 366-8321

F (319) 366-0032

Terracon.com

Facilities | Environmental | Geotechnical | Materials

December 12, 2022

Bancroft Architects + Engineers

700 Nicholas Boulevard, Suite 300

Elk Grove Village, Illinois 60007

Attn: Mr. Vince Bertucci

P: (847) 952-9362

E: vbertucci@bancroft-ae.com

Re: Limited Asbestos and Lead-Containing Paint Survey Report

Project No. 636A8-22-001 Renovate 6th Floor for Clinical Unit

Iowa City VA Health Care System

604 Highway 6 West

Iowa City, Iowa 52246

Terracon Project No. 06227130

Dear Mr. Bertucci:

Terracon Consultants, Inc. (Terracon) is pleased to submit this limited asbestos and lead-containing paint (LCP) survey report to Bancroft Architects + Engineers (Bancroft or the Client) for the above-referenced project. The purpose of this report is to present the results of the limited asbestos and LCP survey performed on November 16 and 17, 2022 in the Iowa City VA Hospital (VA). This survey was conducted in general accordance with Terracon’s Proposal (P06227130) dated August 26, 2022, and the

AIA Document C401-2017 Standard form of Agreement Between Architect and Consultant dated

September 20, 2022. We understand that Bancroft has entered into a prime contract with the

Department of Veterans Affairs to provide architect/engineering services for the project.

Asbestos was identified in several of the sampled materials and surface coatings exhibited concentrations of lead. Other inaccessible materials/areas were also identified and will need to be further investigated once the spaces are vacated. Please refer to the attached survey report for additional details.

Terracon appreciates the opportunity to provide this service to Bancroft Architects + Engineers. If you have questions regarding this report, please contact Taryn at (319) 221-7322 or taryn.rowley@terracon.com.

Sincerely, Terracon Consultants, Inc.

Taryn Rowley Eric Harris

Field Scientist Authorized Project Reviewer mailto:vbertucci@bancroft-ae.com mailto:taryn.rowley@terracon.com https://na3.documents.adobe.com/verifier?tx=CBJCHBCAABAAW5xKtE8NwlqTR3dt3q8a7SbZrQWpvGnO https://na3.documents.adobe.com/verifier?tx=CBJCHBCAABAAW5xKtE8NwlqTR3dt3q8a7SbZrQWpvGnO

Table of Contents

1.0 PROJECT OVERVIEW

1.1 Project Objective

1.2 Reliance

2.0 BUILDING DESCRIPTION

3.0 FIELD ACTIVITIES

3.1 Asbestos Survey

3.1.1 Asbestos Visual Inspection

3.1.2 Asbestos Physical Assessment

3.1.3 Asbestos Sample Collection

3.1.4 Asbestos Sample Analysis

3.2 Lead-Containing Paint Survey

4.0 FINDINGS AND RECOMMENDATIONS

4.1 Asbestos Findings and Recommendations

4.1.1 Asbestos Findings

4.1.2 Asbestos Recommendations

4.2 Lead-Containing Paint Findings and Recommendations

4.2.1 LCP Findings

4.2.2 LCP Recommendations

5.0 LIMITATIONS/GENERAL COMMENTS

Appendices

Appendix A: Tables

Table 1: Identified Asbestos-Containing Materials by Homogeneous Area (HA)

Table 2: Inaccessible Areas and Assumed Asbestos-Containing Materials, Not Sampled

Table 3: Asbestos Survey Sample Summary by HA

Table 4: LCP Sample Summary

Appendix B: Exhibits

Exhibit 1: Sample Location Diagram – 6th Floor

Exhibit 2: ACM Location Diagram – 6th Floor

Exhibit 3: Inaccessible Areas Map – 6th Floor

Appendix C: Laboratory Analytical Report and COC

Appendix D: Photographic Documentation

Appendix E: Regulatory Overview

Appendix F: Inspector Licenses and Calibration Certificates

Limited Asbestos and LCP Survey Report

636A8-22-001 6th Floor Renovation | Iowa City, Iowa

December 12, 2022 | Terracon Report No. 06227130

Facilities | Environmental | Geotechnical | Materials 4

1.0 PROJECT OVERVIEW

1.1 Project Objective

Terracon Consultants, Inc. (Terracon) conducted a limited asbestos and lead-containing paint survey at the Iowa City VA Hospital (VA) Building 1 located at 604 Highway West, Iowa City, Iowa. Terracon understands that these services were requested in anticipation of the renovation of approximately

22,500 square feet of the 6th floor of Building 1 (the project area). This survey was conducted in general accordance with Terracon’s Proposal (P06227130) dated August 26, 2022 and the AIA

Document C401-2017 Standard form of Agreement Between Architect and Consultant dated

September 20, 2022. We understand that Bancroft has entered into a prime contract with the

Department of Veterans Affairs to provide architect/engineering services for the project.

Terracon utilized the Shive-Hattery Architecture + Engineering (Shive) Building 1, Floors Sub-basement – 10 – Asbestos Survey document dated May 13, 2016, associated tabulated survey data, and the ICVAHCS Asbestos Survey (DVA No 263-P-1225) Drawings dated June 10, 2016 (collectively, the Shive Survey) to aid in our investigation. As part of our Survey, Terracon identified additional homogeneous areas of suspect asbestos-containing materials (ACM) from the project area, as generally defined above. The additional suspect ACMs were documented, and the results are presented herein.

Although reasonable effort was made to survey accessible suspect materials, additional suspect but unsampled materials could be located in walls, in voids, or in other concealed areas or areas where investigation was not feasible without causing significant damage to finishes. Suspect ACM samples were collected in accordance with the sampling protocols outlined in United States Environmental

Protection Agency (USEPA) 40 Code of Federal Regulations (CFR) Part 763-Asbestos, Subpart E-

Asbestos-Containing Materials in Schools (known as the Asbestos Hazard Emergency Response Act

[AHERA]). Asbestos samples were delivered to an accredited laboratory for analysis by polarized light microscopy (PLM).

At the time of the Survey, the project area was occupied and/or still in operation. Terracon was provided access to the available spaces by VA Project Manager, Mr. Benjamin Mitchell.

1.2 Reliance

This report is for the exclusive use of the Bancroft Architects + Engineers. Reliance by any other party is prohibited without written authorization of Terracon and Bancroft Architects + Engineers. Reliance on this report by Bancroft Architects + Engineers and all authorized parties is subject to the terms, conditions, and limitations stated in the signed agreement for services and this report.

Facilities | Environmental | Geotechnical | Materials 5

2.0 BUILDING DESCRIPTION

The following table provides a general summary of building information and construction information such as structure and finishes used within the building.

Table A. General Building Information

3.0 FIELD ACTIVITIES

The asbestos survey was conducted by Mr. Ian Bootsmiller and Mr. Alex Davis, state of Iowa licensed asbestos inspectors (license #’s 22-7971 and 22-9073, respectively) on November 16 and 17, 2022.

Copies of their asbestos inspector licenses are included in Appendix F. The asbestos survey was conducted in accordance with the sample collection protocols established in USEPA 40 CFR 763.86, Sampling. A summary of survey activities is provided below.

Building Description and Information

Address 604 Highway 6 West, Iowa City, Iowa

Building Use Medical Center

Building Construction

Main Structure Concrete and Brick

Roof type Built-up membrane

Flooring Structure Reinforced concrete

Floor Coverings Vinyl floor tile, hardwood, vinyl sheet flooring, carpet, terrazzo, and bare concrete

Interior Walls Concrete, plaster, and drywall

Ceilings Reinforced concrete and acoustical ceiling tile

HVAC Equipment Combination FHA- AC

Facilities | Environmental | Geotechnical | Materials 6

3.1 Asbestos Survey

3.1.1 Asbestos Visual Inspection

Survey activities were initiated with visual observation of the interior of the Project Area to identify and document homogeneous areas of suspect ACM. The Shive Survey was utilized as deemed appropriate by the inspector. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color and texture with consideration given to the date of application.

The assessment was conducted in visually accessible areas of the Project Area. Although reasonable effort was made to survey accessible suspect materials, additional suspect but unsampled materials could be located in walls, in voids, or in other concealed areas.

Due to the potential for significant damage to certain building components and the need for the spaces to remain operational, some materials could not be accessed/removed or sampled, and therefore, were assumed to be ACM; please refer to Table 2 in Appendix A for a listing of these materials. Our survey activities also excluded elevator shafts, elevator lobbies, elevator cabs, stairwells, and roof(s) on 6th floor.

3.1.2 Asbestos Physical Assessment

A physical assessment of each HA of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material that can be crumbled, pulverized, or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.

3.1.3 Asbestos Sample Collection

Based on results of the visual observation, bulk samples of suspect ACM were collected in accordance with the sampling protocols outlined in 40 CFR 763.86 – Sampling. Samples of suspect materials were collected from randomly selected locations in each HA. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker. The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogenous in content.

It should be emphasized that ACMs could be present in inaccessible areas such as walls, voids, or other concealed areas. In the event that materials are discovered during demolition that have not been characterized, they should be sampled prior to disturbance to determine if they contain asbestos or they can be assumed to contain asbestos and appropriately abated.

Terracon collected 48 bulk samples from 16 HAs of suspect ACM in the survey area. A summary of suspect ACM samples collected during the survey is provided in Table 3 in Appendix A and is included as part of the chain of custody (COC) presented in Appendix C. Exhibit 1 in Appendix B depicts the approximate sample locations. Representative photographs are presented in Appendix D.

Facilities | Environmental | Geotechnical | Materials 7

3.1.4 Asbestos Sample Analysis

Bulk samples were submitted under COC to EMSL Analytical, Inc. (EMSL) in Pineville, North Carolina for analysis by polarized light microscopy (PLM) with dispersion staining techniques in accordance with

USEPA’s Method for the Determination of Asbestos in Bulk Building Materials (600/R-93-116). The percentage of asbestos, if present, was determined by microscopic visual estimation. EMSL is NVLAP accredited (lab code 200841-0).

3.2 Lead-Containing Paint Survey

The LCP portion of the survey was completed by Mr. Bootsmiller and Mr. Davis concurrently with the asbestos survey. The purposes of the LCP survey were to assess for the presence of lead in coatings that might be present in materials that might be impacted by project.

Terracon collected six paint samples from painted substrates likely to be impacted by the project.

Terracon utilized a wood chisel and write-on, sealable sample bags to collect paint chips from the different surface coatings. The sample was delivered under COC to EMSL Cinnaminson, New Jersey for analysis of lead by USEPA SW-846 Methods 3050B Acid Digestion of Sediments, Sludges, and Soils and 7000B Flame Atomic Absorption Spectrophotometry. However, due to the lab running overcapacity, these samples were forwarded to EMSL’s Pineville, North Carolina lab. EMSL is ELLAP accredited (lab code 200841-0).

4.0 FINDINGS AND RECOMMENDATIONS

4.1 Asbestos Findings and Recommendations

4.1.1 Asbestos Findings

The following materials were identified to greater than 1% asbestos during Terracon’s survey:

▪ Thermal systems insulation (TSI) - white insulation associated with mudded joints

▪ TSI - grey insulation associated with mudded joints

▪ TSI- cloth wrapped corrugated pipe insulation

▪ 12-inch (”)x12” off-white floor tile with grey streaks and associated black adhesive

▪ 12”x12” white floor tile with tan streaks and associated black adhesive

▪ Black adhesive associated with 12”x12” tan floor tile

Facilities | Environmental | Geotechnical | Materials 8

▪ TSI - white magnesia (mag) pre-formed pipe insulation and associated cloth wrap

The Shive Report identified the following ACMs in the project area:

▪ Off-white floor tile under carpet

Table 1 included in Appendix A identifies the confirmed ACMs, sample locations, and approximate quantities, along with additional information. Table 3 included in Appendix A summarize the bulk asbestos samples collected as part of the project. Exhibits showing the approximate sampling locations and the approximate locations and extents of confirmed ACMs are provided in Appendix B.

Photographs of the select ACMs are presented in Appendix C. EMSL’s laboratory analytical reports and the COCs are included in Appendix D.

Without significant demolition installed flooring materials, built-ins and due to the spaces being occupied, we cannot determine the full extent of these materials at this time.

Due to the limitations placed on this Survey, Terracon was not able to investigate for the presence of select materials due to the potential for significant damage to the building materials and due to the fact that the spaces were generally occupied at the time of the Survey efforts. Table 2 in Appendix A includes a list of inaccessible areas/spaces.

4.1.2 Asbestos Recommendations

As the National Standards for Hazardous Air Pollutants (NESHAP) and Occupational Safety and Health

Administration’s (OSHA) regulations govern the removal of ACMs, Terracon recommends that a qualified contractor be hired to properly abate and dispose of ACMs identified within this report in accordance with an asbestos abatement specification; local, state, and federal regulations; and the demolition plans set forth by the design team.

The owner and/or operator are responsible for USEPA NESHAP regulatory compliance regarding the proper removal, handling, and disposal of ACMs containing greater than 1% asbestos prior to renovation or demolition. Also, per state regulations, please be aware that the owner and/or operator must notify the Iowa Department of Natural Resources (IDNR) 10-business days prior to asbestos abatement at certain quantity thresholds and prior to demolition activities.

It is likely that asbestos containing adhesives extend under walls, base cabinets and other built-ins.

Due to the location of the ACMs, the abatement contractor shall be prepared to complete significant demolition to gain access to the materials. Additionally, we recommend carpeting and other floor coverings directly adhered to ACM, be treated as ACM waste.

Any assumed (as indicated in Table 2 in Appendix A) and unsampled suspect ACMs needs to be further investigated once the spaces are vacated and significant demolition can occur to assess for the presence of the suspected ACMs. Terracon’s contract includes a return inspection once all spaces have been vacated; the return inspections needs to be completed well in advance of any demolition activity.

Facilities | Environmental | Geotechnical | Materials 9

Should project design plans change / additional work areas be added to the project scope, additional investigation will be warranted. If additional but unsampled suspect ACMs are revealed during renovation or demolition activities, the material(s) must be assumed to contain asbestos and treated as such unless sampled by an accredited inspector and laboratory analysis determines otherwise.

Our contract includes services for developing asbestos abatement specifications (project design) and for performing abatement oversight and air monitoring. We recommend that Bancroft confirms with the VA contact that these services are requested.

A summary of applicable asbestos regulations is provided in Appendix F.

4.2 Lead-Containing Paint Findings and Recommendations

4.2.1 LCP Findings

One paint chip sample was reported by the laboratory at a concentration of 0.5% by weight (the

USEPA definition of lead-based paint (LBP). The LBP identified in room 6E230 appears to extend through the floor and is ls located on plaster walls; the paint may also extend into other areas that are not included as part of this scope of services. The analytical laboratory also reported three other paint chips with concentrations of lead but below the definition of LBP. The result of the limited lead containing paint sampling is included in Table 4 in Appendix A. The lead laboratory analytical report is included in Appendix C. Select photos are provided in Appendix B. A summary of lead regulations is provided in Appendix E.

4.2.2 LCP Recommendations

Terracon recommends that the contractor(s) involved in the demolition/renovation be notified of the presence of LBP and LCP on various surface coatings. The OSHA lead standards for construction (29

CFR 1926.62) apply regardless of the lead concentrations and contractor(s) will need to provide appropriate personal protective equipment and conduct personal exposure monitoring, at a minimum.

The levels indicated could create conditions above published occupational exposure limits. No other substances were analyzed.

If waste materials containing LCP are generated, they may be regulated as hazardous waste. Lead containing paint waste from renovation activities, such as debris, paint chips, dust, and sludges, that exhibit the toxicity characteristic must be managed and disposed of as a hazardous waste under the

Resource Conservation and Recovery Act (RCRA), except whole-building demolition debris. The hazardous waste criterion for lead wastes is established under 40 CFR 261, as 5.0 milligrams per liter

(mg/L) measured by the Toxicity Characteristic Leaching Procedure (TCLP). A summary of lead regulations is provided in Appendix E.

Facilities | Environmental | Geotechnical | Materials 10

5.0 LIMITATIONS/GENERAL COMMENTS

Terracon did not perform sampling that required demolition or destructive activities such as knocking holes in walls, dismantling of equipment, or removal of protective coverings. Reasonable efforts to access suspect materials within known areas of restricted access (e.g., above ceiling grids, in pipe chases) were made. Please note that final demolition and/or renovation plans were not provided to

Terracon at the onset of these services. Terracon relied on documentation provided in the 2016 Shive

Survey of the Iowa City VA to conduct the limited asbestos portion of the survey. Limitations associated with the 2016 Shive Survey were not provided to Terracon.

Terracon’s proposal P06227130 dated August 26, 2022, included costs for a supplemental inspection that will be conducted once the floor has been vacated by all VA operations and prior to construction/demolition activities. During this supplemental inspection, Terracon’s Iowa licensed asbestos inspectors will access suspect materials that have been assumed during this initial survey.

This task will include destructive investigation of materials that will be removed from the project areas.

This Survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during our survey of the project area as generally defined herein. The information contained in this report is relevant to the date on which this survey was performed and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by Bancroft for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.

Appendix A: Tables

A-1

TABLE 1 – IDENTIFIED ASBESTOS-CONTAINING MATERIALS BY HOMOGENEOUS AREA (HA)

The materials listed in this table have been sampled by others and determined to contain asbestos in concentrations greater than 1%. When disturbed, various federal, state, and local regulations will apply. Please refer to the attached Exhibit in Appendix B for the general location of the ACs and for additional notes.

HA

Sample ID Sample Description General Location Sample Location

Total Asbestos Percentage and Type

Estimated Quantity1/Notes

02 2-MJ1-04

Thermal systems insulation (TSI) - white insultation associated with mudded joints

Rooms 6E17C2 and 6E16

Room 6E17C2 – above ceiling in northeast corner

10% Amosite

30% Chrysotile

25 SF

Due to the limited nature of this survey, Terracon was not able to evaluate the extent of this material without completing destructive investigation. This ACM is likely to be present between walls and in wall chases. Additional investigation is warranted.

TSI - grey insulation associated with mudded joints

75% Chrysotile

02-MJ1-05 TSI - white insultation associated with mudded joints

Room 6E16 – above ceiling on west side

10% Amosite

40% Chrysotile

TSI - grey insulation associated with mudded joints

70% Chrysotile

02-MJ1-06 TSI - white insultation associated with mudded joints

Room 6E17C2 – above ceiling in northeast corner

15% Amosite

30% Chrysotile

TSI - grey insulation associated with mudded joints

70% Chrysotile

1 Estimated quantities are based on a cursory field evaluation and actual quantities may vary significantly, especially if ACMs are present in hidden and/or inaccessible areas not evaluated as part of this survey. LF = linear feet; SF = square feet

A-2

HA

Sample ID Sample Description General Location Sample Location

Total Asbestos Percentage and Type

Estimated Quantity1/Notes

03 03-PI2-07 TSI - cloth wrapped corrugated pipe insulation

Rooms 6E17C2, 6E16, and 6E17A

Room 6E17C2 – above ceiling in northeast corner

75% Chrysotile 85 LF

Due to the limited nature of this survey, Terracon was not able to evaluate the extent of this material without completing destructive investigation. This ACM is likely to be present between walls and in wall chases. Additional investigation is warranted.

03-PI2-09 Room 6E17A – above ceiling on west side

75% Chrysotile

07 07-FT2-20 12”x12” off-white floor tile with grey streaks

Rooms 6E18, 6E19, 6E17A, 6E17B, 6E17C, 6E17D, 6E25-6E35, 6E02, 6E03, 6N01, 6W06, 6W09

Room 6W09 – east side of entry way

7% Chrysotile 3,150 SF

Black adhesive 5% Chrysotile

07-FT2-21 12”x12” off-white floor tile with grey streaks Room 6E17D – west side of room

6% Chrysotile

Black adhesive 4% Chrysotile

A-3

Sample ID Sample Description General Location Sample Location

Total Asbestos Percentage and Type

Estimated Quantity1/Notes

13 13-FT2-38

12”x12” white floor tile with tan streaks

Room 6E11 and 6E37

Middle of east wall in room 6E37

4% Chrysotile 320 SF

Black adhesive 2% Chrysotile

13-FT2-39 12”x12” white floor tile with tan streaks

5% Chrysotile

Black adhesive 4% Chrysotile

14 14-FT2-40 Black adhesive associated with 12”x12” tan floor tile

Rooms 6E17A and 6E36 (Rooms identified by the Shive Survey:

6E01, 6E02, 6E03, 6E17A 6E17B, 6E17C1, 6E17C2, 6E17D, 6E18, 6E19, 6E24, 6E25, 6E26, 6E28, 6E29, 6E30- 6E5A, 6N01, 6W06, 6W09, 6W20, 6W21A, and 6W22)

West side of patch in room 6E17A

6% Chrysotile 200 SF

Due to the limited nature of this survey, Terracon was not able to evaluate the extent of this material without completing destructive investigation. This ACM is likely to be present under demising walls, buildouts, and other flooring.

Additional investigation is warranted.

14-FT2-41 Middle of north wall in room 6E36

4% Chrysotile

14-FT2-42

Middle of north wall in room 6E36

5% Chrysotile

A-4

Sample ID Sample Description General Location Sample Location

Total Asbestos Percentage and Type

Estimated Quantity1/Notes

16 16-PI1-46 TSI - white magnesia (mag) pre-formed pipe insulation

Room 6E15

South wall chase above ceiling in room 6E15

35% Amosite

10% Chrysotile

24 LF

Due to the limited nature of this survey, Terracon was not able to evaluate the extent of this material without completing destructive investigation. This ACM is likely to be present between walls and in wall chases. Additional investigation is warranted.

16-PI1-47 TSI - white magnesia (mag) pre-formed pipe insulation

40% Amosite

5% Chrysotile

16-PI1-48 TSI - white magnesia (mag) pre-formed pipe insulation

40% Amosite

10% Chrysotile

Building 1 ACM identified in the 2016 Shive Asbestos Survey

34 Unknown Off-white floor tile under carpet

6W07 Unknown

5% Asbestos 80 SF

A-5

TABLE 2 – INACCESSIBLE AREAS AND ASSUMED ASBESTOS-CONTAINING MATERIALS, NOT SAMPLED

Assumed materials are materials that are commonly determined to contain asbestos that could not be sampled during the survey. Reasons for not sampling can include lack of accessibility (VA did not have keys, hard pan ceilings, plaster chases, interlocked ceiling tile, etc.), need for significant demolition to access materials in an occupied space, or other sampling limitations. Additional unidentified materials should be sampled before any renovation or demolition activities that may disturb them to determine their actual asbestos content.

Space Material Descriptions Location Potential Quantity

6W09 Carpet and associated adhesive Walls in room 1,500 SF

Residual adhesive Under raised flooring 900 SF

6E15 Grey plank flooring and associated adhesive

Floors 130 SF

6E17A Grey floor tile and associated adhesive Floors 250 SF

Hallways and patient rooms (6E26, 6E28-6E37)

Carpet and associated adhesive Floors 5,065 SF

Restrooms on 6th floor (6W12, 6W14, 6W02, 6E02A, 6E25A, 6E16, 6E26A, 6E29A, 6E30A, 6E31A, 6E34A, 6E35A, and bathrooms east of room 6E10)

Thin-set and grout associated with ceramic tile

Floors and walls 4,520 SF

6th Floor Windows Black slate Windowsills of all windows on the 6th Floor

Unknown – requires additional assessment

Rooms with exterior walls Adhesive, black Behind walls; former radiator box outs

Unknown

6E19, 6E18, 6E22, 6E01, 6W01, 6W03, 6W07, 6W10, 6W12, 6W15, 6W21A, 6W21B, 6W24, 6W26, 6W27B, 6W33, 6W19A-6W19E

Materials located in these rooms are assumed to be similar to previously sampled materials

Throughout rooms – these rooms were inaccessible at the time of Terracon’s inspection

Unknown – requires additional assessment

A-6

Space Material Descriptions Location Potential Quantity

Hallways on 6th Floor Terrazzo Floors Unknown – requires additional assessment

A-7

TABLE 3 – ASBESTOS SURVEY SAMPLE LOCATION SUMMARY BY HOMOGENOUS AREA (HA)

# Sample ID

Sample Description General Location Sample Location

Total Asbestos Percentage and Type

01 01-CT3-01 2’x2’ orange peel white ceiling tile

All hallways and rooms on 6th floor

Room 6W14 – along east side of room None Detected (ND)

01-CT3-02 Far west end of main hallway on 6th floor ND

01-CT3-03 Room 6E20 – along south side of room ND

02 02-MJ1-04 Thermal systems insulation (TSI) -white insultation associated with mudded joints

Rooms 6E17C2 and 6E16

Room 6E17C2 – above ceiling in northeast corner

10% Amosite

30% Chrysotile

TSI - grey insulation associated with mudded joints

75% Chrysotile

02-MJ1-05 TSI - white insultation associated with mudded joints

Room 6E16 – above ceiling on west side 10% Amosite

40% Chrysotile

TSI - grey insulation associated with mudded joints

70% Chrysotile

02-MJ1-06 TSI - white insultation associated with mudded joints

Room 6E17C2 – above ceiling in northeast corner

15% Amosite

30% Chrysotile

A-8

# Sample ID

Sample Description General Location Sample Location

Total Asbestos Percentage and Type

TSI - grey insulation associated with mudded joints

70% Chrysotile

03 03-PI2-07 TSI - cloth wrapped corrugated pipe insulation

Rooms 6E17C2, 6E16, and 6E17A

Room 6E17C2 – above ceiling in northeast corner

75% Chrysotile

03-PI2-08 Room 6E16 – above ceiling on west side ND

03-PI2-09 Room 6E17A – above ceiling on west side

75% Chrysotile

04 04-CA7-10 Red fire caulk Around piping and wiring on the 6th floor

Men’s restroom near 6E12 near doorway ND

04-CA7-11 Room 6E07 – southeast corner of room ND

04-CA7-12 Far west end of 6th floor hallway above ceiling

ND

05 05-WB1-13 Drywall Rooms 6E20, restroom near 6E12, 6W20, 6W21B, 6E01, 6W16, and above ceilings across 6th floor

Men’s restroom near 6E12 near doorway, northwest corner

ND

Tape ND

Joint compound ND

05-WB1-14 Drywall Room 6E08A – above ceiling on east side ND

Tape ND

Joint compound ND

05-WB1-15 Drywall Far west side of 6th floor hallway, above ceiling

ND

Tape ND

A-9

Sample Description General Location Sample Location

Total Asbestos Percentage and Type

Joint compound ND

06 06-HP1-16 Plaster and thin coat

6th floor hallways and patient rooms

Room 6E07 – above ceiling on south side of room

ND

06-HP1-17 Room 6W17 – above ceiling on pillar ND

06-HP1-18 Room 6E15 – above ceiling on east side ND

07 07-FT2-19 12”x12” off-white floor tile with grey streaks

Rooms 6E18, 6E19, 6E17A, 6E17B, 6E17C, 6E17D, 6E25-6E35, 6E02, 6E03, 6N01, 6W06

Room 6E03 – north side of room

ND

Black adhesive ND

07-FT2-20 12”x12” off-white floor tile with grey streaks

Room 6W09 – east side of entry way

7% Chrysotile

Black adhesive 5% Chrysotile

07-FT2-21 12”x12” off-white floor tile with grey streaks

Room 6E17D – west side of room

6% Chrysotile

Black adhesive 4% Chrysotile

08 08-MJ5-22 White pipe adhesive

Above ceilings throughout the 6the floor on fiberglass pipe joints

Room 6W14 – above center of ceiling ND

08-MJ5-23 Room 6W25 – above ceiling in southwest corner of room

08-MJ5-24 Room 6E28 – above center of ceiling ND

A-10

Sample Description General Location Sample Location

Total Asbestos Percentage and Type

09 09-FC1-25 Brown vinyl sheet flooring

Throughout hallways between rooms 6W22 and 6E35 and room 6E10

In the storage area of room 6E01

ND

Brown adhesive ND

09-FC1-26 Brown vinyl sheet flooring

Southwest corner of room 6E10

ND

Brown adhesive ND

09-FC1-27 Brown vinyl sheet flooring

Northside by doorway in room 6E20

ND

Brown adhesive ND

10 10-FC3-28 6” black cove base and associated tan adhesive

Rooms 6E01-6E09, 6E10-6E13A, 6E20-

6E22, 6CE01-6CE04,

6CN01, 6W19A-6W21,

6W21B, 6W25-6W34, 6CW01-6CW04, 6C01

South wall by door in room 6W32 ND

10-FC3-29 Storage area of room 6C01 ND

10-FC3-30 Middle of south wall in room 6E20 ND

11 11-FC3-31 4” dark brown cove base associated with tan adhesive

Rooms 6E17-6E19, 6E24, 6E26, 6E26A, 6E28-6E37, 6W05, 6W07, 6W08, 6W08A, 6W10, 6W16, 6W21

Southwest corner in room 6E10 ND

11-FC3-32 Middle of north wall in room 6W10 ND

11-FC3-33 Middle of south wall in room 6E28 ND

12 12-CA1-34 Black window caulk Around all windows on the 6th floor

East side window in room 6C01 ND

12-CA1-35 North side window in room 6E30 ND

12-CA1-36 South side window in room 6E31 ND

A-11

Sample Description General Location Sample Location

Total Asbestos Percentage and Type

13 13-FT2-37 12”x12” white floor tile with tan streaks

Room 6E11 and 6E37

Middle of west wall in room 6E11

ND

Black adhesive ND

13-FT2-38 12”x12” white floor tile with tan streaks Middle of east wall in room 6E37

4% Chrysotile

Black adhesive 2% Chrysotile

13-FT2-39 12”x12” white floor tile with tan streaks Middle of east wall in room 6E37

5% Chrysotile

Black adhesive 4% Chrysotile

14 14-FT2-40 12”x12” tan floor tile

Rooms 6E17A and 6E36

West side of patch in room 6E17A

ND

Black adhesive 6% Chrysotile

14-FT2-41 12”x12” tan floor tile

Middle of north wall in room 6E36

ND

Black adhesive 4% Chrysotile

14-FT2-42 12”x12” tan floor tile

Middle of north wall in room 6E36

Black adhesive 5% Chrysotile

A-12

Sample Description General Location Sample Location

Total Asbestos Percentage and Type

15 15-CA5-43 White sink caulk 6th floor bathrooms and patient rooms

Middle of east wall in 6W29 ND

15-CA5-44 Middle of east wall in 6W14 ND

15-CA5-45 Middle of east wall in room 6E17A ND

16 16-PI1-46 TSI - white magnesia (mag) pre-formed pipe insulation

Room 6E15

South wall chase above ceiling in room 6E15

35% Amosite

10% Chrysotile

Cloth Wrap ND

16-PI1-47 TSI - white magnesia (mag) pre-formed pipe insulation

South wall chase above ceiling in room 6E15

40% Amosite

5% Chrysotile

Cloth Wrap ND

16-PI1-48 TSI - white magnesia (mag) pre-formed pipe insulation

South wall chase above ceiling in room 6E15

40% Amosite

10% Chrysotile

Cloth Wrap ND

A-13

TABLE 4 – LCP SAMPLE SUMMARY

Positive results indicate a paint that contains lead. Bold indicates that the result was equal to or above the EPA criterion for lead-based paint (0.5% by weight).

Paint Chip Sample # Location Substrate Color

Paint Chip Sample Result (% by Weight)

Lead-1 West wall in room 6E20 Plaster Tan 0.5

Lead-2 North wall in room 6W19 Drywall Dark Grey <0.0080

Lead-3 East wall in room 6W25 Drywall Light Grey <0.0080

Lead-4 Southwest corner in room 6E10 Plaster White 0.018

Lead-5 East side of room in room 6E15, above ceiling Plaster Tan 0.35

Lead-6 North side of door frame in room 6E20 Metal Brown 0.18

Appendix B: Exhibits tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Text Box Exhibit 1: Sample Location Diagram - 6th Floor tlrowley Text Box Legend

Non-ACM Sample Location (<1% asbestos-containing material)

ACM Sample Location (>1% asbestos-containing material)

LCP Sample Location tlrowley Text Box tlrowley Text Box tlrowley Text Box tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout 01, 22 tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout 25, 29 tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout 10, 13 tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout 38, 39 tlrowley Callout tlrowley Callout tlrowley Callout 41, 42 tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout 46, 47, 48 tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout tlrowley Callout 04, 06 tlrowley Callout

Legend HA-02 White mudded joint

HA-03 Cloth wrapped correlated pipe insulation

HA-07 12"x12" off-white floor tile with associated black mastic

HA-13 12"x12" white with tan streaks floor tile with associated black mastic

HA-14 12"x12" tan floor tile with associated black mastic

HA-16 Cloth wrap, white mag. insulation tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle njfritz Rectangle tlrowley Text Box Exhibit 2: ACM Location Diagram - 6th Floor

Davis, Alex J Rectangle

Davis, Alex J Rectangle

Davis, Alex J Rectangle

Davis, Alex J Rectangle

Davis, Alex J Rectangle

Davis, Alex J Rectangle

Davis, Alex J Rectangle

Davis, Alex J Rectangle

Davis, Alex J Rectangle tlrowley Text Box HA02: Thermal Systems Insulation (TSI) white and gray mudded joint insulation

HA03: Thermal Systems Insulation (TSI) cloth wrapped corrugated pipe insulation

HA07: 12"x12" off-white floor tile with gray streaks and associated black adhesive

HA13: 12"x12" white floor tile with tan streaks and associated black adhesive

HA14: Black adhesive associated with 12"x12" tan floor tile

HA16: Thermal Systems Insulation (TSI), white magnesia (mag) pre-formed pipe insulation and associated cloth wrap tlrowley Text Box Notes 1.These locations are approximate and should be utilized for informational purposes. The abatement contractor should confirm all locations and quantities.

2. Due to the complexity of the piping system, not all Asbestos Containing Material (ACM) TSI runs may be shown.

3.Mudded joint packings associated with all layered paper pipe insulation (and fiberglass runs) are ACM and are not depicted. If there is a hard fitting; it is considered ACM. The pipe hangars also have mudded packings that are ACM.

4. Due to the limited nature of this survey, Terracon was not able to evaluate the extent of flooring adhesives without causing significant damage to building materials. This ACM is likely to extend under demising walls, built-ins, and other furnishings. Additional investigation may be warranted to determine the full extent of the materials.

tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Text Box Exhibit 3: Inaccessible Areas Map - 6th Floor tlrowley Text Box Legend

Inaccessible area - requires further assessment
Rooms with unsampled materials

Davis, Alex J Rectangle

Davis, Alex J Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Area 16,601.28 ft² tlrowley Area 16,835.75 ft² tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Rectangle tlrowley Area 97,018.51 ft²

Appendix C: Laboratory Analytical Report and COC

EMSL Analytical, Inc.

200 Route 130 North Cinnaminson, NJ 08077

Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com

042229108EMSL Order:

Customer ID: ACON77

Customer PO: 06227130

Project ID:

Attention: Phone:Taryn Rowley (319) 366-8321

Fax:Terracon Consultants, Inc. (319) 366-0032

Received Date:2640 12th Street Southwest 11/18/2022 9:40 AM

Analysis Date:Cedar Rapids, IA 52404 11/22/2022

Collected Date: 11/17/2022

Project: VA 6th Floor Renovation, 601 US-6 W. Iowa City, Iowa 52246 / 06227130

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1-CT3-1

042229108-0001

None DetectedPerlite

Non-fibrous (Other)

15%

10%

Cellulose

Min. Wool

60%

15%

Gray/White

Fibrous

Homogeneous

6W14-Along East

Side - 2x2 Orange

Peel White Ceiling

Tile

HA: 1

1-CT3-2

042229108-0002

None DetectedPerlite

Non-fibrous (Other)

15%

10%

Cellulose

Min. Wool

60%

15%

Gray/White

Fibrous

Homogeneous

Far End Of West Side

Hallway - 2x2 Orange

Peel White Ceiling

Tile

HA: 1

1-CT3-3

042229108-0003

None DetectedPerlite

Non-fibrous (Other)

5%

15%

Cellulose

Min. Wool

60%

20%

Beige

Fibrous

Homogeneous

6E20 - Along South

Side - 2x2 Orange

Peel White Ceiling

Tile

HA: 1

2-MJ1-4-Wrap

042229108-0004

None DetectedNon-fibrous (Other)10%Cellulose90%White

Fibrous

Homogeneous

6E17C2-Above

Ceiling NE Corner -

White Mudded Joint

HA: 2

2-MJ1-4-White

Insulation

042229108-0004A

10%

30%

Amosite

Chrysotile

Non-fibrous (Other)60%White

Non-Fibrous

Homogeneous

6E17C2-Above

Ceiling NE Corner -

White Mudded Joint

HA: 2

2-MJ1-4-Gray Insulation

042229108-0004B

75% ChrysotileNon-fibrous (Other)25%Gray

Fibrous

Homogeneous

6E17C2-Above

Ceiling NE Corner -

White Mudded Joint

HA: 2

2-MJ1-5-White

Insulation

042229108-0005

10%

40%

Amosite

Chrysotile

Non-fibrous (Other)50%White

Non-Fibrous

Homogeneous

6E16 - Above Ceiling

West Side - White

Mudded Joint

HA: 2

2-MJ1-5-Gray Insulation

042229108-0005A

70% ChrysotileNon-fibrous (Other)30%Gray

Non-Fibrous

Homogeneous

6E16 - Above Ceiling

West Side - White

Mudded Joint

HA: 2

2-MJ1-6-Wrap

042229108-0006

None DetectedNon-fibrous (Other)1%Cellulose99%White

Fibrous

Homogeneous

6E17C2 Above

Ceiling NE Corner -

White Mudded Joint

HA: 2

2-MJ1-6-White

Insulation

042229108-0006A

15%

30%

Amosite

Chrysotile

Non-fibrous (Other)55%White

Fibrous

Homogeneous

6E17C2 Above

Ceiling NE Corner -

White Mudded Joint

HA: 2

2-MJ1-6-Gray Insulation

042229108-0006B

70% ChrysotileNon-fibrous (Other)30%Gray

Fibrous

Homogeneous

6E17C2 Above

Ceiling NE Corner -

White Mudded Joint

HA: 2

Initial report from: 11/23/2022 13:17:04

Page 1 of 7ASB_PLM_0008_0001 - 1.78 Printed: 11/23/2022 1:17 PM

Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com

042229108EMSL Order:

Customer ID: ACON77

Customer PO: 06227130

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

3-PI2-7-Wrap

042229108-0007

None DetectedNon-fibrous (Other)5%Cellulose95%Gray/White

Fibrous

Homogeneous

6E17C2 Above

Ceiling NE Corner -

Cloth Wrap

Corregated Pipe

Insulation

HA: 3

3-PI2-7-Insulation

042229108-0007A

75% ChrysotileNon-fibrous (Other)25%Gray

Fibrous

Homogeneous

6E17C2 Above

Ceiling NE Corner -

Cloth Wrap

Corregated Pipe

Insulation

HA: 3

3-PI2-8-Wrap

042229108-0008

None DetectedNon-fibrous (Other)5%Cellulose95%White

Fibrous

Homogeneous

6E16 Above Ceiling

West Side - Cloth

Wrap Corregated

Pipe Insulation

HA: 3

3-PI2-8-Insulation

042229108-0008A

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

6E16 Above Ceiling

West Side - Cloth

Wrap Corregated

Pipe Insulation

HA: 3

3-PI2-9-Wrap

042229108-0009

None DetectedNon-fibrous (Other)1%Cellulose99%White

Fibrous

Homogeneous

6E17A Above Ceiling

West Side - Cloth

Wrap Corregated

Pipe Insulation

HA: 3

3-PI2-9-Insulation

042229108-0009A

75% ChrysotileNon-fibrous (Other)25%White

Fibrous

Homogeneous

6E17A Above Ceiling

West Side - Cloth

Wrap Corregated

Pipe Insulation

HA: 3

4-CA7-10

042229108-0010

None DetectedNon-fibrous (Other)98%Glass2%Red

Non-Fibrous

Homogeneous

Men's Restroom Near

6E12 - Red Fire Caulk

HA: 4

4-CA7-11

042229108-0011

None DetectedNon-fibrous (Other)98%Glass2%Red

Non-Fibrous

Homogeneous

6E07 South Wall (Se

Corner) - Red Fire

Caulk

HA: 4

4-CA7-12

042229108-0012

None DetectedNon-fibrous (Other)90%Glass10%Red

Non-Fibrous

Homogeneous

Far West End Of

Hallway Above

Ceiling - Red Fire

Caulk

HA: 4

5-WB1-13-Drywall

042229108-0013

None DetectedNon-fibrous (Other)95%Cellulose5%Brown/Gray

Fibrous

Homogeneous

Men's Restroom Near

6E12 - Drywall

HA: 5

5-WB1-13-Mud

042229108-0013A

None DetectedCa Carbonate

Non-fibrous (Other)

35%

65%

White

Non-Fibrous

Homogeneous

Men's Restroom Near

6E12 - Mud

HA: 5

5-WB1-13-Caulk

042229108-0013B

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

White

Non-Fibrous

Homogeneous

Men's Restroom Near

6E12 - Mud

HA: 5

Page 2 of 7ASB_PLM_0008_0001 - 1.78 Printed: 11/23/2022 1:17 PM

Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com

042229108EMSL Order:

Customer ID: ACON77

Customer PO: 06227130

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

5-WB1-14-Drywall

042229108-0014

None DetectedNon-fibrous (Other)95%Cellulose5%Brown/Gray

Fibrous

Homogeneous

6E08A Above Ceiling

East Side - Drywall

HA: 5

5-WB1-14-Mud

042229108-0014A

Layer Not Present6E08A Above Ceiling

East Side - Mud

HA: 5

5-WB1-14-Caulk

042229108-0014B

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

White

Non-Fibrous

Homogeneous

6E08A Above Ceiling

East Side - Mud

HA: 5

5-WB1-15-Drywall

042229108-0015

None DetectedNon-fibrous (Other)95%Cellulose5%White

Non-Fibrous

Homogeneous

Far West Side OF

Hallway Above

Ceiling - Drywall

HA: 5

5-WB1-15-Mud

042229108-0015A

None DetectedCa Carbonate

Non-fibrous (Other)

30%

70%

White

Non-Fibrous

Homogeneous

Far West Side OF

Hallway Above

Ceiling - Mud

HA: 5

6-HP1-16-Plaster

042229108-0016

None DetectedQuartz

Non-fibrous (Other)

35%

65%

Gray

Non-Fibrous

Homogeneous

6E07 Above Ceiling

South Side - Plaster

HA: 6

6-HP1-16-Thin Coat

042229108-0016A

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

White

Non-Fibrous

Homogeneous

6E07 Above Ceiling

South Side - Thin

Coat

HA: 6

6-HP1-17-Plaster

042229108-0017

None DetectedQuartz

Non-fibrous (Other)

35%

65%

Gray

Non-Fibrous

Homogeneous

6W17 Above Ceiling

On Pillar - Plaster

HA: 6

6-HP1-17-Thin Coat

042229108-0017A

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

White

Non-Fibrous

Homogeneous

6W17 Above Ceiling

On Pillar - Thin Coat

HA: 6

6-HP1-18-Plaster

042229108-0018

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Tan

Non-Fibrous

Homogeneous

6E15 Above Ceiling

East Side - Plaster

HA: 6

6-HP1-18-Thin Coat

042229108-0018A

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

White

Non-Fibrous

Homogeneous

6E15 Above Ceiling

East Side - Thin Coat

HA: 6

7-FT2-19-Floor Tile

042229108-0019

None DetectedCa Carbonate

Non-fibrous (Other)

25%

75%

White

Non-Fibrous

Homogeneous

6E03 North Side -

12x12 Off-white Floor

Tile, Gray Streaks

HA: 7

7-FT2-19-Mastic

042229108-0019A

None DetectedNon-fibrous (Other)100%Tan/Black

Non-Fibrous

Homogeneous

6E03 North Side -

Black Mastic

HA: 7

7-FT2-20-Floor Tile

042229108-0020

7% ChrysotileNon-fibrous (Other)93%Gray/White

Non-Fibrous

Homogeneous

6W09 East Side Entry

Way - 12x12 Off-white

Floor Tile, Gray

Streaks

HA: 7

Page 3 of 7ASB_PLM_0008_0001 - 1.78 Printed: 11/23/2022 1:17 PM

Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com

042229108EMSL Order:

Customer ID: ACON77

Customer PO: 06227130

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

7-FT2-20-Mastic

042229108-0020A

5% ChrysotileNon-fibrous (Other)95%Tan/Black

Non-Fibrous

Homogeneous

6W09 East Side Entry

Way - Black Mastic

HA: 7

7-FT2-21-Floor Tile

042229108-0021

6% ChrysotileNon-fibrous (Other)94%Tan

Non-Fibrous

Homogeneous

6E17D West Side -

12x12 Off-white Floor

Tile, Gray Streaks

HA: 7

7-FT2-21-Mastic

042229108-0021A

4% ChrysotileNon-fibrous (Other)96%Black

Non-Fibrous

Homogeneous

6E17D West Side -

Black Mastic

HA: 7

8-MJ5-22-Mastic

042229108-0022

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

White

Non-Fibrous

Homogeneous

6W14 Above Ceiling

Center - White Pipe

Mastic

HA: 8

8-MJ5-22-Insulation

042229108-0022A

None DetectedNon-fibrous (Other)5%Glass95%Yellow

Fibrous

Homogeneous

6W14 Above Ceiling

Center - White Pipe

Mastic

HA: 8

8-MJ5-23-Mastic

042229108-0023

None DetectedCa Carbonate

Non-fibrous (Other)

15%

85%

White

Non-Fibrous

Homogeneous

6W25 Above Ceiling

SW Corner - White

Pipe Mastic

HA: 8

8-MJ5-23-Insulation

042229108-0023A

None DetectedNon-fibrous (Other)5%Glass95%Yellow

Fibrous

Homogeneous

6W25 Above Ceiling

SW Corner - White

Pipe Mastic

HA: 8

8-MJ5-24-Mastic

042229108-0024

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

White

Fibrous

Homogeneous

6E28 Above Ceiling

Center - White Pipe

Mastic

HA: 8

8-MJ5-24-Insulation

042229108-0024A

None DetectedNon-fibrous (Other)1%Glass99%Yellow

Fibrous

Homogeneous

6E28 Above Ceiling

Center - White Pipe

Mastic

HA: 8

9-FC1-25-Sheet

Flooring

042229108-0025

None DetectedNon-fibrous (Other)90%Synthetic10%Gray/White

Fibrous

Homogeneous

6E01 Storage Area -

Brown Vinyl Sheet

Flooring

HA: 9

9-FC1-25-Adhesive/Lev eler

042229108-0025A

None DetectedQuartz

Non-fibrous (Other)

5%

90%

Cellulose5%Gray/Clear

Fibrous

Heterogeneous

6E01 Storage Area -

Brown Adhesive

HA: 9

9-FC1-26-Sheet

Flooring

042229108-0026

None DetectedNon-fibrous (Other)95%Synthetic5%Gray/White

Fibrous

Homogeneous

6E10 Southwest

Corner - Brown Vinyl

Sheet Flooring

HA: 9

9-FC1-26-Adhesive